createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1706506159126
version3
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyRESERVED
invitingStrategyTextReserved
taxTypeINCLUSIVE_TAX
tenderFee500.00
emd15653.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose06-02-2024 17:30:00
tenderQueryClose05-02-2024 17:30:00
technicalBidOpen08-02-2024 11:00:00
publishedDate29-01-2024 18:43:42
publishedByPostRDPR_EE_DIV_BGK
publishedByUserKPE18661 - MALLANAGOUDA R BIRADAR
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonEE PRED BAGALKOTE
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08354235042
mobileNumber8660966508
tenderSupplierListNone
tenderSchedule
createdTs1706506159166
version6
createdDateNone
modifiedDateNone
tenderNumberRDPR/2023-24/BD/WORK_INDENT1644
titleConstruction of anganavadi-03 Building at Ganjihal in Hungund taluka of bagalakote district
descriptionConstruction of anganavadi-03 Building at Ganjihal in Hungund taluka of Bagalakote district
categoryWORKS
categoryTextWorks
ecv1252283.84
deptNameRural Development and Panchayat Raj Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location796
locationNameRDPR Division Office Bagalakote
provisionalAmount1500000.0
groupOverheadTotal0.0
fileNumberAEE/PRE/HND/Ganjihal-03/Anganavadi/2023-24
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17065061590000NoneNoneBuildingsConstruction of anganavadi-03 Building at Ganjihal in Hungund taluka of bagalakote district1252283.84
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
232009568572None1.15.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work (PWD CSR 2021-22 Vol -1 P.No.8 I.No 1.15.1)n ordinary/soft rock without blasting upto 1.5 m depthCum272.0272.05.58FalseNoneNoneFalseNoneFalse1517.760
232009668572None2.1.2Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8 (M5) Using 40 mm nominal size graded crushed coarse aggregates (PWD CSR 2021-22 Volume -1 Pg.No 15. I.No 2.1.2)Cum5364.05364.01.74FalseNoneNoneFalseNoneFalse9333.360
232009768572None5.1.1Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) .PWD CSR 2021-22 Volume -2 P No 9 ; I No 5.1.1Cum4824.04824.011.16FalseNoneNoneFalseNoneFalse53835.840
232009868572None2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) (PWD CSR 2021-22 Vol -1 P No 17. I.No 2.5.1 ) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum10509.410509.42.59FalseNoneNoneFalseNoneFalse27219.3460
232009968572None2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) (PWD CSR 2021-22 Vol -1 P No 17. I.No 2.5.1 ) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum9891.29891.25.21FalseNoneNoneFalseNoneFalse51533.1520
232010068572None2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) (PWD CSR 2021-22 Vol -1 P No 17. I.No 2.5.1 ) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum9273.09273.010.57FalseNoneNoneFalseNoneFalse98015.610
232010168572None2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) (PWD CSR 2021-22 Vol -1 P No 17. I.No 2.5.1 ) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum8963.98963.90.48FalseNoneNoneFalseNoneFalse4302.6720
232010268572None11.32Providing Thermo-Mechanically Treated bars of grade Fe-550D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) (PWD CSR 2022 Vol-2 Page No-84 Item No 11.32Kg92.092.01557.28FalseNoneNoneFalseNoneFalse143269.760
232010368572None6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. (PWD CSR 2021-22 Vol -2 P No-14 I No-6.8 )Cum6690.06690.025.76FalseNoneNoneFalseNoneFalse172334.40
232010468572None8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (PWD CSR 2021-22 Vol -2 P No-41 I No-8.1.1 )Sqm213.0213.0214.52FalseNoneNoneFalseNoneFalse45692.760
232010568572None8.9Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.PWD CSR 2021-22 Volume -2 P.No-42 I.No-8.9Sqm322.0322.0293.52FalseNoneNoneFalseNoneFalse94513.440
232010668572None12.12Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications. PWD CSR 2021-22 Volume 2 P.No-100 I.No-12.12Cum75344.075344.00.12FalseNoneNoneFalseNoneFalse9041.280
232010768572None12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. PWD CSR 2021-22 Volume -2 P.No-105 I.No-12.51No1485.01485.02.0FalseNoneNoneFalseNoneFalse2970.00
232010868572None11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding PWD CSR 2021-22 Volume -2 P.No-85 I.No-11.34AKg145.0145.0113.4FalseNoneNoneFalseNoneFalse16443.00
232010968572None12.86Providing & fixing of 2-trackx2-panel sliding windows made out of multi chambered UPVC (Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame the outer frame having an overall size of 50mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mmx57mm with Gi reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5 mm. Windows shall be provided with 5mm plain float glass, standard hardware & single point locking system with touch lock Wall thickness of frame& sash shall be of 1.8+0.2 mm. Maximum possible size 1519mm x1519mm The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made PWD CSR 2021-22 vol2Sqm5842.05842.07.56FalseNoneNoneFalseNoneFalse44165.520
232011068572None12.15Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures ) (PWD Common Schedule of Rate 2021-22 Page No-100 Item No-12.15 (Vol -2)Sqm5074.05074.03.23FalseNoneNoneFalseNoneFalse16389.020
232011168572None12.54Providing and fixing factory made PVC Door frame of size 50x47mm with as wall thickness of 5mm made out of extruded 5mm ridig PVC form sheewt metered cut of corners & jointed 2 Nos. of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinfeorced with 19x19mm M.S. Square tube of 19 gauge. The door frame to be fixed to the wall usiong M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge of workSqm475.0475.01.24FalseNoneNoneFalseNoneFalse589.00
232011268572None12.53Providing & fixing 30mm thick factory made rigid foam Panelled Door Shutters made from M.S. tube of 19 gauge thickness, size 19x19mm for stiles and 15x15mm for top & bottom rails, covered with heat moulded PVC C channel of 5mm thick sheet & 30 x 50mm wide to form stiles & 5mm thick & 75mm wide PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick 20mm wide PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet fitted in the M.S. Frame, Sealed to the stiles & rails with 5x30mm PVC sheet beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75 mm Aluminium hinges.(PWD CSR 2021-22 Vol -2 P No-105 I No-12.53Sqm287.0287.01.24FalseNoneNoneFalseNoneFalse355.880
232011368572None9.30Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.(PWD CSR 2021-22 Vol -2 P.No-64 / I.No-9.30 )Sqm2395.02395.071.78FalseNoneNoneFalseNoneFalse171913.10
232011468572None9.9Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete.PWD CSR 2021-22 Vol -2 P No-60 I No-9.9Sqm620.0620.03.6FalseNoneNoneFalseNoneFalse2232.00
232011568572None10.14Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete.PWD CSR 2021-22 Vol -2 PNo-71 I No-10.14Sqm974.0974.08.15FalseNoneNoneFalseNoneFalse7938.10
232011668572None10.142.5cms thick Shahabad slabs(PWD CSR 2021-22 Vol -2 P No-A 33SI No-10.14Sqm355.0355.016.11FalseNoneNoneFalseNoneFalse5719.050
232011768572None8.33.2Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(PWD CSR 2021-22 Vol -2 P No-46 I No-8.33.2Sqm105.0105.010.65FalseNoneNoneFalseNoneFalse1118.250
232011868572None8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge (PWD CSR 2021-22 Vol -2 P No-50 I No-8.51Sqm83.083.0237.44FalseNoneNoneFalseNoneFalse19707.520
232011968572None8.25Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD CSR 2021-22 Vol -2 P No-45 I No-8.25Sqm105.0105.0279.89FalseNoneNoneFalseNoneFalse29388.450
232012068572None8.30Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(PWD CSR 2021-22 Vol -2 P No-46 I No-8.30Sqm136.0136.0294.62FalseNoneNoneFalseNoneFalse40068.320
232012168572None14.1.1Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests(PWD CSR 2021-22 Page No.123, Item No. 14.1.1 Vol -2)No4246.04246.01.0FalseNoneNoneFalseNoneFalse4246.00
232012268572None13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.PWD CSR 2021-22 Vol -2 P.No- I.No-13.34l8.08.01000.0FalseNoneNoneFalseNoneFalse8000.00
232012368572None13.33.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal sibility for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 25 mm ,nominal dia Pipes PWD CSR 2021-22 Vol -2 P.No- SI.No-13.33.3 25 MM Diam299.0299.020.0FalseNoneNoneFalseNoneFalse5980.00
232012468572None14.7AProviding and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: using White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer(PWD CSR 2021-22 Page No.125, Item No. 14.7A Vol -2)No3778.953778.951.0FalseNoneNoneFalseNoneFalse3778.950
232012568572None69415 mm C.P.brass tap PWD CSR 2021-22 Vol 2 P.No- A-33 SI.No-694No270.0270.02.0FalseNoneNoneFalseNoneFalse540.00
232012668572None13.33.7Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal sibility for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 65 mm ,nominal dia Pipes PWD CSR 2021-22 Vol -2 P.No- SI.No-13.33.7m1397.01397.010.0FalseNoneNoneFalseNoneFalse13970.00
232012768572None11.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (PWD CSR 2021-22 Vol -2, P No.83 I No 11.28 )Kg500.0500.063.0FalseNoneNoneFalseNoneFalse31500.00
232012868572None9.31Providing and laying heavy duty cobble stones 60mm thick interlock pavers, using cement and course sand for manufacture of blocks of approved size, shape and colour with a minimum compressive strength of 281 kg per m2 over 50mm thick sand bed ( average thickness ) and compacting with plate vibrator having 3 tons compaction force thereby forcing part of sand underneath to come up in between joints, final compaction of paver surface joints into its final level , including cost of materials, labour and Usage charges of machinery complete as per specifications. (PWD CSR 2021-22 Volume -2 Page No.64 Item No 9.31)Sqm1087.01087.012.0FalseNoneNoneFalseNoneFalse13044.00
232012968572None11.3Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement,stoppers, handles, including applying a priming coat of approved steel primer including cost of materials ,labour, usage charges of machinery complete as per specificationsand as per directions of the Engineer-in-ChargePWD CSR 2021-22 Volume -2 P.No 75. I.No 11.3Sqm6569.06569.05.04FalseNoneNoneFalseNoneFalse33107.760
232013068572None11.4Providing and fixing 1 mm thick M.S. sheet sliding-shutters, with frame and diagonal braces of 40x40x6 mm angle iron, 3 mm M.S. gusset plates at the junctions and corners, 25 mm dia pulley, 40x40x6 mm angle and T- iron guide at the top and bottom respectively, including applying a priming coat of approved steel primer including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.PWD CSR 2021-22 Volume -2 P.No 75. I.No 11.4Sqm4330.04330.05.04FalseNoneNoneFalseNoneFalse21823.20
232013168572None7.1Providing and fixing G.I. chain link fabric fencing of required width inmesh size 50x50 mm including strengthening with 2 mm dia wire ornuts, bolts and washers as required complete as per the direction ofEngineer-in-charge. (Made of G.I. wire of dia 4 mm)m2 RWS SR 2022 , P-187 , I- 7.1Sqm676.0676.08.64FalseNoneNoneFalseNoneFalse5840.640
232013268572None1.2.1Concealed Conduit System Supplying heavy gauge PVC conduit pipe ……mm dia .mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. 19/20mm dia 2mm thick ( P No 2 ; I No 1.2.1)m40.040.045.0FalseNoneNoneFalseNoneFalse1800.00
232013368572None1.3.1Supplying heavy gauge PVC Conduit Pipe ….dia .mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.m51.051.020.0FalseNoneNoneFalseNoneFalse1020.00
232013468572None1.6.3Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood. After due groove cutting, necessary masonary patch work complete.No77.077.04.0FalseNoneNoneFalseNoneFalse308.00
232013568572None2.1.1Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP A.Point200.0200.04.0FalseNoneNoneFalseNoneFalse800.00
232013668572None2.1.2Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP A.Point275.0275.04.0FalseNoneNoneFalseNoneFalse1100.00
232013768572None2.1.3Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP A.Long point above 6Mtr upto 10Mtr from tapping point to out let via switch ( P No 5 ; I No 2.1.3)Point400.0400.04.0FalseNoneNoneFalseNoneFalse1600.00
232013868572None2.3.1Wiring for lighting/power circuit using one of PVC insulated 1100V grade, multis and Copper conductor single core cable in open or consealed system of wiring. Using Class 'A' approved materials.1 sqmm (P.No. 5, I.No. 2.3.1)m14.014.080.0FalseNoneNoneFalseNoneFalse1120.00
232013968572None2.3.3Wiring for lighting/power circuit using one of PVC insulated 1100V grade, multis and Copper conductor single core cable in open or consealed system of wiring. Using Class 'A' approved materials.m32.032.0130.0FalseNoneNoneFalseNoneFalse4160.00
232014068572None2.3.4Wiring for lighting/power circuit using one of PVC insulated 1100V grade, multis and Copper conductor single core cable in open or consealed system of wiring. Using Class 'A' approved materials.4sqmmm45.045.050.0FalseNoneNoneFalseNoneFalse2250.00
232014168572None3.1.2Supply 6A flush/projected type socket and a 6 amps flush/ projected type SP switch either surface/flush mounting in a existing gang box or in a 4mm thick plastic sheet and fixing over a flush monted wooden box and wiring using necessary capacity wires as required.6 Amps 3/5 Way ( P No 9 ; I No 3.1.2 )No132.0132.012.0FalseNoneNoneFalseNoneFalse1584.00
232014268572None3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.32 Amps DP switch( P No 10 ; I No 3.6.10)No182.0182.04.0FalseNoneNoneFalseNoneFalse728.00
232014368572None3.6.11Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.No162.0162.08.0FalseNoneNoneFalseNoneFalse1296.00
232014468572None3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.No290.0290.02.0FalseNoneNoneFalseNoneFalse580.00
232014568572None3.9Supplying and fixing hylum plastic sheet 3mm thick with necessary nitches for fixing switches, regulators etc., and fixing on existing wood or metal box using N.F. screws.(P No 10 ; I No 3.9)Sq CM0.240.242200.0FalseNoneNoneFalseNoneFalse528.00
232014668572None12.5.2Supply of round/square recess/surface mounted rolling type LED Down light with .W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical conditionNo768.0768.08.0FalseNoneNoneFalseNoneFalse6144.00
232014768572None5.6.1Supplying and fixing polished wood board made of not lees then 15mm thick plank on both side with planks made out of more then 2 pieces and fixing the same to the wall using taperd inverted wooden flugs screws etc.No70.070.04.0FalseNoneNoneFalseNoneFalse280.00
232014868572None5.7.2Supplying & fixing of porcelain fuse channel with cut on existing wooden /panel using necessary nuts, bolts and washers etc, complete.No174.0174.04.0FalseNoneNoneFalseNoneFalse696.00
232014968572None5.17.4Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.No909.0909.02.0FalseNoneNoneFalseNoneFalse1818.00
232015068572None5.18.7Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure.( II Double Door).No1450.01450.03.0FalseNoneNoneFalseNoneFalse4350.00
232015168572None6.1Supplying, fixing & wiring, earth electrode for ground conduits. I.C. cutouts and other equipements, on the meter board using 40mm dia 2.90 thick of GI pipe 2.5 mtr long burid in a pit. The pit sholud be gilled with equal pro[ortion of salt and charcoal 150mm alround the pipe to completedepth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per clause 7.3.3 of is 732 using 12mm dia bolts, nuts, washers, & check nut etc., The pipe shall have 16 through holes of 12mm dia.No2999.72999.71.0FalseNoneNoneFalseNoneFalse2999.70
232015268572None1.1.1Supplying heavy gauge PVC conduit pipe …….dia .mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.m50.050.025.0FalseNoneNoneFalseNoneFalse1250.00
232015368572None7.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system.No2090.02090.01.0FalseNoneNoneFalseNoneFalse2090.00
232015468572None14.1.2Supplying and Fixing of.mm dia class A GI pipe bracket up to 2 mtrs long bent at suitable angle and fixing to this bracket 1x40/2x40 watts fluorescent tube street light fitting of all capacities to GI or CI or rail or RCC pole / wall using suitable clamps, bolts, and nuts and wiring using suitable capacity wires.No835.0835.01.0FalseNoneNoneFalseNoneFalse835.00
232015568572None14.7.1Fixing all types and all capacities fluorescent/ false ceiling/spot light/ CFL fittings indoor on the wall/ceiling/rafters/girders using 23/0.0076'' twin PVC insulated wires, required nos of round blocks and clamps (if required)No110.0110.09.0FalseNoneNoneFalseNoneFalse990.00
232015668572None14.9Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. (P No 80 ; I No 14.9)No260.0260.02.0FalseNoneNoneFalseNoneFalse520.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17065061600000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17065061600000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17065061600000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17065061810000NoneNoneELIGIBILITYThe Project Completion period is 8 Months and the defect liability period of the work is (2) TWO year after successful completion of the work. (including Monsoon).None
17065061860000NoneNoneELIGIBILITYWork Completion/Execution Period : 8 MonthsNone
17065061920001NoneNoneELIGIBILITYThis work is Randomized under LOT 846 Sl No 24 and which is classified as :SC Category work. Hence this work is purely reserved for SC Category Bidders only.None
17065061980000NoneNoneELIGIBILITYFor this work only eligible SC contractor (with cast certificate) should applyNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneTenderer must have valid Class-II &Above contractor Civil registered in KPWD / PRED must submit the registration copyPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneBidder should posses at least 25% of having Any nature cost of work done certificate certified by an officer of rank not less than Rs.3.13 lakhs Executive Engineer in the last 5 years.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneTo qualify for award of this contact each tenderer in his name should have in the last 2018-19 TO 2022-23 FIVE years period achieved in at least two financial years an average financial turnover of Rs 12.52 Lakhs usually not less than amount put to tender from from C.A. on Letter Head with UDIN No. otherwise bid will be directly disqualifiedPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneWorkdone certificate certified by an officer of rank not less than Executive Engineer for Maximum civil engineering works done during last five yearsPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneList of works on HandPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- WORK IN HAND
NoneNoneNoneNoneTenderers who meet the above specified minimum qualifying criteria, will only be qualified, if their available tender capacity is more than the total tender value. The available tender capacity will be calculated as under Assessed available tender capacity A X N X 5 -BPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- BID CAPACITY
NoneNoneNoneNoneFor this work only eligible SC Contractor with caste certificate should applyPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- RESERVED CERTIFICATE
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Tenderer must have valid Class-II &Above contractor Civil registered in KPWD / PRED must submit the registration copyTrueTechnical Bid
Bidder should posses at least 25 PERECENT of having Any nature cost of work done certificate certified by an officer of rank not less than Rs.3.13 lakhs Executive Engineer in the last 5 years.TrueTechnical Bid
To qualify for award of this contact each tenderer in his name should have in the last 2018-19 TO 2022-23 FIVE years period achieved in at least two financial years an average financial turnover of Rs 12.52 Lakhs usually not less than amount put to tender from from C.A. on Letter Head with UDIN No. otherwise bid will be directly disqualifiedTrueTechnical Bid
Workdone certificate certified by an officer of rank not less than Executive Engineer for Maximum civil engineering works done during last five yearsTrueTechnical Bid
List of works on HandTrueTechnical Bid
Tenderers who meet the above specified minimum qualifying criteria, will only be qualified, if their available tender capacity is more than the total tender value. The available tender capacity will be calculated as under Assessed available tender capacity A X N X 5 - BTrueTechnical Bid
For this work only eligible SC Contractor with caste certificate should applyTrueTechnical Bid
tenderWorkLocationList
tenderSubEstimateNamedistrictNametaluqNameloksabhaContNameassemblyContNamelocationDescriptionlatitudeDegreeslatitudeMinuteslatitudeSecondslongitudeDegreeslongitudeMinuteslongitudeSeconds
BuildingsBagalkoteHungundaBagalkotHUNGUNDGANJIHALNoneNoneNoneNoneNoneNone
tenderAddressNone
tenderRecallDTONone