| 1706532843000 | 1 | None | None | Buildings | Construction of Two Classrooms to Govt Higher Primary School in Mitesuguru Village of Siruguppa Taluk of Ballari Dist Under Pradanamantri Adi Adarsh Gram Yojana | 1710990.4 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 2330284 | 68893 | None | code01 | Demolishing cement concrete manually/ by mechanical means including disposal of material to the appropriate disposal area as per direction of Engineer-in-charge | Cum | 469.35 | 469.35 | 21.63 | False | None | None | False | None | False | 10152.0405 | 0 | | 2330285 | 68893 | None | code02 | Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineerin-charge | Cum | 1354.5 | 1354.5 | 61.84 | False | None | None | False | None | False | 83762.28 | 0 | | 2330286 | 68893 | None | code03 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. | Cum | 195.3 | 195.3 | 120.715 | False | None | None | False | None | False | 23575.6395 | 0 | | 2330287 | 68893 | None | code04 | Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) | Cum | 5720.4 | 5720.4 | 17.47 | False | None | None | False | None | False | 99935.388 | 0 | | 2330288 | 68893 | None | code05 | M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all otherappurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) Colum footing | Cum | 6593.07 | 6593.07 | 13.095 | False | None | None | False | None | False | 86336.25165 | 0 | | 2330289 | 68893 | None | code06 | M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all otherappurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) colum | Cum | 10377.99 | 10377.99 | 4.554 | False | None | None | False | None | False | 47261.36646 | 0 | | 2330290 | 68893 | None | code07 | M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) p.beam | Cum | 9157.05 | 9157.05 | 4.23 | False | None | None | False | None | False | 38734.3215 | 0 | | 2330291 | 68893 | None | code08 | M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) Lintel Roof Beam | Cum | 9767.52 | 9767.52 | 8.49 | False | None | None | False | None | False | 82926.2448 | 0 | | 2330292 | 68893 | None | code09 | M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) Slab | Cum | 9157.05 | 9157.05 | 15.335 | False | None | None | False | None | False | 140423.36175 | 0 | | 2330293 | 68893 | None | code10 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) | Kgs | 94.5 | 94.5 | 3636.77 | False | None | None | False | None | False | 343674.765 | 0 | | 2330294 | 68893 | None | code11 | Providing Random rubble masonry with hard stone in foundation
and plinth including levelling up with cement concrete 1:6:12 (1 cement
: 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto
plinth level | Cum | 3228.75 | 3228.75 | 20.55 | False | None | None | False | None | False | 66350.8125 | 0 | | 2330295 | 68893 | None | code12 | Providing Size Stone masonry with hard stone in foundation & plinth
with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 3864.0 | 3864.0 | 15.09 | False | None | None | False | None | False | 58307.76 | 0 | | 2330296 | 68893 | None | code13 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work | Cum | 6991.95 | 6991.95 | 24.6 | False | None | None | False | None | False | 172001.97 | 0 | | 2330297 | 68893 | None | code14 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m | Cum | 214.2 | 214.2 | 197.945 | False | None | None | False | None | False | 42399.819 | 0 | | 2330298 | 68893 | None | code15 | M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately | Cum | 8851.81 | 8851.81 | 0.27 | False | None | None | False | None | False | 2389.9887 | 0 | | 2330299 | 68893 | None | code16 | Providing and fixing 1mm thick M.S. sheet door with frame of 40 X 40 X6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as perdirections of the Engineer-in-Charge | Sqm | 3528.0 | 3528.0 | 5.04 | False | None | None | False | None | False | 17781.12 | 0 | | 2330300 | 68893 | None | code17 | Providing and fixing factory made ISI marked steel glazed doors,windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars
tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) including cost of materials,labour, usage charges of machinery complete as per specificationsand as per directions of the Engineer in charge | Sqm | 126.0 | 126.0 | 226.8 | False | None | None | False | None | False | 28576.8 | 0 | | 2330301 | 68893 | None | code18 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding | Kgs | 150.15 | 150.15 | 227.0 | False | None | None | False | None | False | 34084.05 | 0 | | 2330302 | 68893 | None | code19 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all coloursnand shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm | Sqm | 1135.05 | 1135.05 | 107.25 | False | None | None | False | None | False | 121734.1125 | 0 | | 2330303 | 68893 | None | code20 | Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge | Sqm | 287.7 | 287.7 | 276.21 | False | None | None | False | None | False | 79465.617 | 0 | | 2330304 | 68893 | None | code21 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge | Sqm | 87.15 | 87.15 | 197.36 | False | None | None | False | None | False | 17199.924 | 0 | | 2330305 | 68893 | None | code22 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 99.75 | 99.75 | 473.57 | False | None | None | False | None | False | 47238.6075 | 0 | | 2330306 | 68893 | None | code23 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper
smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 94.5 | 94.5 | 35.64 | False | None | None | False | None | False | 3367.98 | 0 | | 2330307 | 68893 | None | code24 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineerin-Charge | Kgs | 116.55 | 116.55 | 75.6 | False | None | None | False | None | False | 8811.18 | 0 | | 2330308 | 68893 | None | code25 | Supplying heavy gauge PVc conduit pipe 19/20mm dia 2mm thick confirming to IS 2509 with suitable size bends metal / PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosurees, run with 18 SWG GI fishs wire wherever necessary | m | 68.0 | 68.0 | 90.0 | False | None | None | False | None | False | 6120.0 | 0 | | 2330309 | 68893 | None | code26 | Supplying and fixing sheet metal box made out of 18 SWG sheet metal with necessary holes for calbe/conduit entry ass required with one coat of primer of approved make etc., 180 x 90 x 65mm | Each | 155.0 | 155.0 | 2.0 | False | None | None | False | None | False | 310.0 | 0 | | 2330310 | 68893 | None | code27 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wring with specified IS-694:1990 & confirming to GTP of GROUP-A 4 sqm | m | 59.0 | 59.0 | 80.0 | False | None | None | False | None | False | 4720.0 | 0 | | 2330311 | 68893 | None | code28 | Supplying and wiring asdopting loop system in existing PVC conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2x1.5sqmm calbe confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet GROUP A Medium point above 3mtr upto 6 mtr from tapping point to out let via switch box. | Each | 361.0 | 361.0 | 10.0 | False | None | None | False | None | False | 3610.0 | 0 | | 2330312 | 68893 | None | code29 | Supplying and fixing of Bakelite DP / Socket/switch with/without neon indicator over existing wood board or flush mounting in plastic plates/nitches as per IS 1293 and IS 3854 GROUP-A 32Amps flush/projected type DP switch | Each | 2000.0 | 2000.0 | 1.0 | False | None | None | False | None | False | 2000.0 | 0 | | 2330313 | 68893 | None | code30 | Supplying and fixing superior qualityh moudlar switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws, bolts nuts etc., complete on the existing metal/PVC box 4 module. | Each | 88.0 | 88.0 | 6.0 | False | None | None | False | None | False | 528.0 | 0 | | 2330314 | 68893 | None | code31 | Supply of rond /square racess / surfacess mounted rolling type LED down light with …w GU 10Led lamp rib fabricated from die cast alminium with wite powder coated prewierd to mains connector & has swivelling unit power coated .LED Square or round down light 10-12w | Each | 835.0 | 835.0 | 6.0 | False | None | None | False | None | False | 5010.0 | 0 | | 2330315 | 68893 | None | code32 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' type curve indictor ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63 Amps TPN | Each | 2399.0 | 2399.0 | 1.0 | False | None | None | False | None | False | 2399.0 | 0 | | 2330316 | 68893 | None | code33 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system.48" Sweep (1200 mm) Regular model | Each | 2085.0 | 2085.0 | 4.0 | False | None | None | False | None | False | 8340.0 | 0 | | 2330317 | 68893 | None | code34 | Lettering with black Japan paint of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | cm | 3.0 | 3.0 | 3500.0 | False | None | None | False | None | False | 10500.0 | 0 | | 2330318 | 68893 | None | code35 | Providing and fixing glass/Ceramic Steel Green Dry Erase Writing Boards Gem Rate | Sqm | 2175.0 | 2175.0 | 5.04 | False | None | None | False | None | False | 10962.0 | 0 |
|