| 2305455 | 67997 | None | code01 | Providing 20 mm cement plaster with cement mortar 1:3 (1 cement:
3 coarse sand) finished with a floating coat of neat cement to
brick/stone masonry including rounding off corners wherever required
smooth rendering, providing and removing scaffolding, including cost
of materials, labour, curing complete as per specifications and as per
directions of Engineer-in-charge. | Sqm | 382.84 | 382.84 | 198.37 | False | None | None | False | None | False | 75943.9708 | 0 |
| 2305456 | 67997 | None | code02 | Providing and fixing factory made ISI marked steel glazed doors,
windows and ventilators, side /top /centre hung, with beading and all
members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design | Kgs | 127.26 | 127.26 | 504.0 | False | None | None | False | None | False | 64139.04 | 0 |
| 2305457 | 67997 | None | code03 | Providing flooring with 25mm thick polished Cuddapah slabs using
cement mortar 1:6, 25mm thick over existing cement concrete bed or
top of roof laid to line and level and jointed with cement slurry mixed
with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications | Sqm | 1302.29 | 1302.29 | 170.339 | False | None | None | False | None | False | 221830.77631 | 0 |
| 2305458 | 67997 | None | code04 | Wall painting with acrylic emulsion paint of approved brand and
manufacture to give an even shade :Two coats on new work after
thoroughly brooming the surface to remove all dirt, dust, mortar drops
and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as
per directions of Engineer-in-charge. | Sqm | 100.75 | 100.75 | 267.12 | False | None | None | False | None | False | 26912.34 | 0 |
| 2305459 | 67997 | None | code05 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 69.99 | 69.99 | 121.67 | False | None | None | False | None | False | 8515.6833 | 0 |
| 2305460 | 67997 | None | code06 | Lettering with black Japan paint of approved brand and manufacture
to give an even shade including preparing the surface after thoroughly
cleaning the surface to remove all dirt, dust and foreign matter, cost of
materials, labour complete as per specifications and as per directions
of Engineer-in-charge | cm | 3.18 | 3.18 | 2250.0 | False | None | None | False | None | False | 7155.0 | 0 |
| 2305461 | 67997 | None | code07 | Supplying heavy gauge PVC conduit pipe mm dia mm thick confirming to IS 2509 with suitable size bends,metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 1 9/20 mm dia 2mm thick | Mtr | 61.0 | 61.0 | 50.0 | False | None | None | False | None | False | 3050.0 | 0 |
| 2305462 | 67997 | None | code08 | Supplying heavy gauge PVC conduit pipe mm dia mm thick confirming to IS 2509 with suitable size bends,metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25mm dia 2mm thick | Mtr | 70.0 | 70.0 | 50.0 | False | None | None | False | None | False | 3500.0 | 0 |
| 2305463 | 67997 | None | code09 | Supplying and fixing sheet metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc.100x75x75mm | Each | 112.0 | 112.0 | 4.0 | False | None | None | False | None | False | 448.0 | 0 |
| 2305464 | 67997 | None | code10 | Supplying and fixing sheet metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc.180X90X65mm | Each | 155.0 | 155.0 | 4.0 | False | None | None | False | None | False | 620.0 | 0 |
| 2305465 | 67997 | None | code11 | Supplying and fixing PVC/metal conduit Deep junction box 19/20mm Deep Junction Box | Each | 49.0 | 49.0 | 4.0 | False | None | None | False | None | False | 196.0 | 0 |
| 2305466 | 67997 | None | code12 | Supplying and fixing PVC/metal conduit Deep junction box 25mm Deep Junction Box | Each | 51.0 | 51.0 | 3.0 | False | None | None | False | None | False | 153.0 | 0 |
| 2305467 | 67997 | None | code13 | Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete.upto 50mm Conduit in Brick Walls | Mtr | 21.0 | 21.0 | 8.0 | False | None | None | False | None | False | 168.0 | 0 |
| 2305468 | 67997 | None | code14 | Supplying And Fixing Metal Fan Box with Round Hook | Nos | 85.0 | 85.0 | 8.0 | False | None | None | False | None | False | 680.0 | 0 |
| 2305469 | 67997 | None | code15 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS 694 and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.A Short piont up to 3 Mtr from tapping piont out let via switch | Each | 251.0 | 251.0 | 8.0 | False | None | None | False | None | False | 2008.0 | 0 |
| 2305470 | 67997 | None | code16 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS 694 and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.A medium piont above 3Mtr to 6 Mtr from tapping piont out let via switch. | Each | 361.0 | 361.0 | 30.0 | False | None | None | False | None | False | 10830.0 | 0 |
| 2305471 | 67997 | None | code17 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694 confirming to latest amendments.1.5 Sqmm | Mtr | 26.0 | 26.0 | 150.0 | False | None | None | False | None | False | 3900.0 | 0 |
| 2305472 | 67997 | None | code18 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694 confirming to latest amendments.2.5 Sqmm | Mtr | 40.0 | 40.0 | 150.0 | False | None | None | False | None | False | 6000.0 | 0 |
| 2305473 | 67997 | None | code19 | Supplying and fixing superior quality switch mounting poly carbonate plate with necessary supporting back plate with required nos of machine tools, bolts, nuts etc., complete on the existing metal/PVC box 4 Module | Each | 125.0 | 125.0 | 4.0 | False | None | None | False | None | False | 500.0 | 0 |
| 2305474 | 67997 | None | code20 | Supplying and fixing superior quality switch mounting poly carbonate plate with necessary supporting back plate with required nos of machine tools, bolts, nuts etc., complete on the existing metal/PVC box 8Module | Each | 200.0 | 200.0 | 6.0 | False | None | None | False | None | False | 1200.0 | 0 |
| 2305475 | 67997 | None | code21 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6Amps one way | Each | 88.0 | 88.0 | 35.0 | False | None | None | False | None | False | 3080.0 | 0 |
| 2305476 | 67997 | None | code22 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 Stepped fan regulator | Each | 313.0 | 313.0 | 8.0 | False | None | None | False | None | False | 2504.0 | 0 |
| 2305477 | 67997 | None | code23 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 16 Amps one way | Each | 249.0 | 249.0 | 8.0 | False | None | None | False | None | False | 1992.0 | 0 |
| 2305478 | 67997 | None | code24 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6/16Amps universal socket | Each | 249.0 | 249.0 | 8.0 | False | None | None | False | None | False | 1992.0 | 0 |
| 2305479 | 67997 | None | code25 | Supplying and fixing 32A security and energy saving DPswitch with key tag suitable to operate on 230 V, 50Hz AC supply & completely wired on existing box. | Each | 747.0 | 747.0 | 1.0 | False | None | None | False | None | False | 747.0 | 0 |
| 2305480 | 67997 | None | code26 | Supplying &fixing of procelain fuse channel with cut out on existing wodden/panel using necessary nuts,bolts and washwer 32Amps | Each | 200.0 | 200.0 | 2.0 | False | None | None | False | None | False | 400.0 | 0 |
| 2305481 | 67997 | None | code27 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and c Type curve, indicator ON/OFF energy cross-3 withShort circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 Amps SP | Each | 523.0 | 523.0 | 1.0 | False | None | None | False | None | False | 523.0 | 0 |
| 2305482 | 67997 | None | code28 | Supplying fixing and wiring electronic trivector meter(ETV) 5 to 32/36 Amps three phase 4 wire whole current class-1 accuracy energy meter | Each | 5125.0 | 5125.0 | 1.0 | False | None | None | False | None | False | 5125.0 | 0 |
| 2305483 | 67997 | None | code29 | supplying ,fixing wiring earth for grounding conduits I.C cutouts and other equibments on the meter board using 40mm dia 2.90mm thick gi pipe 2.5m long buried ina a pit the pit should be filled with equal propotion of salt and chorchal 150mm all round the pipe to complete depth the connection from the pipe to conduit etc is to be established thorugh gi wire of size as per isi specification | Each | 3750.0 | 3750.0 | 1.0 | False | None | None | False | None | False | 3750.0 | 0 |
| 2305484 | 67997 | None | code30 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts,50 cycles. Single phase AC supply conforming to ISS-3741979 and with double ball bearing system.48" Sweep (1200mm) Regular model | Each | 2085.0 | 2085.0 | 8.0 | False | None | None | False | None | False | 16680.0 | 0 |
| 2305485 | 67997 | None | code31 | Supplying of feet PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours & 70 percent lumen maintenance with CRI greater 80. Power Input: 220240V at 50/60Hz Power factor greater 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. | Each | 740.0 | 740.0 | 20.0 | False | None | None | False | None | False | 14800.0 | 0 |
| 2305486 | 67997 | None | code32 | Supplying and fixing of 5'-80 Watts of T8 Fluorescent Tube with 54W power consumption with low 3mg Mercury content less phosphor coating. Operating voltage range from 180V to 265V, 50Hz AC power Supply | Nos | 510.0 | 510.0 | 10.0 | False | None | None | False | None | False | 5100.0 | 0 |
| 2305487 | 67997 | None | code33 | Supplying of patty fitting, made out of CRCA Sheet metal body with locking type holder completely wired with HF Electronic Ballast, Operating voltage range from 180V to 265V, 50Hz AC power supply excluding Tube. | Each | 310.0 | 310.0 | 15.0 | False | None | None | False | None | False | 4650.0 | 0 |
| 2305488 | 67997 | None | code34 | Supplying & Fixing of 70-150 Watts lamp holder 2 Pin | Nos | 118.0 | 118.0 | 20.0 | False | None | None | False | None | False | 2360.0 | 0 |
| 2305489 | 67997 | None | code35 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. | Each | 119.0 | 119.0 | 30.0 | False | None | None | False | None | False | 3570.0 | 0 |
| 2305490 | 67997 | None | code36 | Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. | Each | 281.0 | 281.0 | 8.0 | False | None | None | False | None | False | 2248.0 | 0 |