| 2305541 | 68001 | None | CODE01 | Earth work in surface excavation for stripping, seating of bund, Road way, by manual means for lowering & leveling the ground for all works other than foundation & depth in all kinds of soil not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. | Cum | 73.5 | 73.5 | 114.75 | False | None | None | False | None | False | 8434.125 | 0 |
| 2305542 | 68001 | None | CODE02 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 m | Cum | 208.95 | 208.95 | 145.05 | False | None | None | False | None | False | 30308.1975 | 0 |
| 2305543 | 68001 | None | CODE03 | Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. | Cum | 126.0 | 126.0 | 66.15 | False | None | None | False | None | False | 8334.9 | 0 |
| 2305544 | 68001 | None | CODE04 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5720.4 | 5720.4 | 17.43 | False | None | None | False | None | False | 99706.572 | 0 |
| 2305545 | 68001 | None | CODE05 | Footing: Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6564.73 | 6564.73 | 11.07 | False | None | None | False | None | False | 72671.5611 | 0 |
| 2305546 | 68001 | None | CODE06 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 10377.99 | 10377.99 | 3.15 | False | None | None | False | None | False | 32690.6685 | 0 |
| 2305547 | 68001 | None | CODE07 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 214.2 | 214.2 | 90.69 | False | None | None | False | None | False | 19425.798 | 0 |
| 2305548 | 68001 | None | CODE08 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 4945.5 | 4945.5 | 17.0 | False | None | None | False | None | False | 84073.5 | 0 |
| 2305549 | 68001 | None | CODE09 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 5580.75 | 5580.75 | 10.92 | False | None | None | False | None | False | 60941.79 | 0 |
| 2305550 | 68001 | None | CODE10 | Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge. | Sqm | 207.9 | 207.9 | 24.64 | False | None | None | False | None | False | 5122.656 | 0 |
| 2305551 | 68001 | None | CODE11 | Plint Beam: Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 9494.1 | 9494.1 | 2.76 | False | None | None | False | None | False | 26203.716 | 0 |
| 2305552 | 68001 | None | CODE12 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. | Cum | 422.1 | 422.1 | 46.01 | False | None | None | False | None | False | 19420.821 | 0 |
| 2305553 | 68001 | None | CODE13 | Column: Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 10759.98 | 10759.98 | 2.72 | False | None | None | False | None | False | 29267.1456 | 0 |
| 2305554 | 68001 | None | CODE14 | Roof Beam and Lintel:: Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 10127.04 | 10127.04 | 3.92 | False | None | None | False | None | False | 39697.9968 | 0 |
| 2305555 | 68001 | None | CODE15 | Roof Slab:: Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 9494.1 | 9494.1 | 13.55 | False | None | None | False | None | False | 128645.055 | 0 |
| 2305556 | 68001 | None | CODE16 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 9177.63 | 9177.63 | 0.18 | False | None | None | False | None | False | 1651.9734 | 0 |
| 2305557 | 68001 | None | CODE17 | Cill Concrete: Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6104.7 | 6104.7 | 1.21 | False | None | None | False | None | False | 7386.687 | 0 |
| 2305558 | 68001 | None | CODE18 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) | Kgs | 94.5 | 94.5 | 3598.45 | False | None | None | False | None | False | 340053.525 | 0 |
| 2305559 | 68001 | None | CODE19 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Sqm | 6991.95 | 6991.95 | 20.32 | False | None | None | False | None | False | 142076.424 | 0 |
| 2305560 | 68001 | None | CODE20 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in foundations and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Sqm | 857.85 | 857.85 | 5.18 | False | None | None | False | None | False | 4443.663 | 0 |
| 2305561 | 68001 | None | CODE21 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding | Kgs | 150.15 | 150.15 | 194.67 | False | None | None | False | None | False | 29229.7005 | 0 |
| 2305562 | 68001 | None | CODE22 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for
100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Size 62 x 150mm | Sqm | 840.0 | 840.0 | 6.9 | False | None | None | False | None | False | 5796.0 | 0 |
| 2305563 | 68001 | None | CODE23 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. | Nos | 1559.25 | 1559.25 | 1.0 | False | None | None | False | None | False | 1559.25 | 0 |
| 2305564 | 68001 | None | CODE24 | Providing and fixign fActory made 100% carpenter friendly ready to use single solid plain wood polymer Composite (WPC) flush shutter of 35mm thickness which is anti termite and having high water absorption property. The cost includes cost of materials, transportation, labour and fixing charges. | Sqm | 4235.7 | 4235.7 | 2.52 | False | None | None | False | None | False | 10673.964 | 0 |
| 2305565 | 68001 | None | CODE25 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. | Sqm | 498.75 | 498.75 | 5.7 | False | None | None | False | None | False | 2842.875 | 0 |
| 2305566 | 68001 | None | CODE26 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. with both side prelam | Sqm | 3993.15 | 3993.15 | 1.58 | False | None | None | False | None | False | 6309.177 | 0 |
| 2305567 | 68001 | None | CODE27 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 256.2 | 256.2 | 99.78 | False | None | None | False | None | False | 25563.636 | 0 |
| 2305568 | 68001 | None | CODE28 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 309.75 | 309.75 | 174.97 | False | None | None | False | None | False | 54196.9575 | 0 |
| 2305569 | 68001 | None | CODE29 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm | Sqm | 1151.85 | 1151.85 | 44.34 | False | None | None | False | None | False | 51073.029 | 0 |
| 2305570 | 68001 | None | CODE30 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. | Sqm | 793.8 | 793.8 | 1.8 | False | None | None | False | None | False | 1428.84 | 0 |
| 2305571 | 68001 | None | CODE31 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. | Sqm | 1083.6 | 1083.6 | 12.17 | False | None | None | False | None | False | 13187.412 | 0 |
| 2305572 | 68001 | None | CODE32 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 87.15 | 87.15 | 125.78 | False | None | None | False | None | False | 10961.727 | 0 |
| 2305573 | 68001 | None | CODE33 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 99.75 | 99.75 | 125.78 | False | None | None | False | None | False | 12546.555 | 0 |
| 2305574 | 68001 | None | CODE34 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 117.6 | 117.6 | 175.92 | False | None | None | False | None | False | 20688.192 | 0 |
| 2305575 | 68001 | None | CODE35 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. G.I. pipes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer- in-Charge. | Kgs | 154.35 | 154.35 | 291.11 | False | None | None | False | None | False | 44932.8285 | 0 |
| 2305576 | 68001 | None | CODE36 | PProviding & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6 PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets -grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 44mm width x 40mmheight with reinforcement of 1mm thickness and Sash with overall size of 27mm X 53mm with UPVC honeycomb structure inside in lieu of GI reinforcement. Coextruded Glazing bead for fixing of glass shall be of size 9.5mm x 21.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with Crescent Locks. Wall thickness of frame & sash shall be of 2 mm.Maximum possible size 1219mm x 1219mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) | Sqm | 4319.7 | 4319.7 | 5.4 | False | None | None | False | None | False | 23326.38 | 0 |
| 2305577 | 68001 | None | CODE37 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) | Sqm | 5113.5 | 5113.5 | 1.35 | False | None | None | False | None | False | 6903.225 | 0 |
| 2305578 | 68001 | None | CODE38 | Providing and laying heavy duty cobble stones 60mm thick interlock pavers, using cement and course sand for manufacture of blocks of approved size, shape and colour with a minimum compressive strength of 281 kg per m2 over 50mm thick sand bed ( average thickness ) and compacting with plate vibrator having 3 tons compaction force thereby forcing part of sand underneath to come up in between joints, final compaction of paver surface joints into its final level , including cost of materials, labour and Usage charges of machinery complete as per specifications. | Sqm | 1141.35 | 1141.35 | 38.5 | False | None | None | False | None | False | 43941.975 | 0 |
| 2305579 | 68001 | None | CODE39 | PLUMBING: Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. In all kinds of soils. Depth upto 1.50m | Cum | 493.5 | 493.5 | 1.62 | False | None | None | False | None | False | 799.47 | 0 |
| 2305580 | 68001 | None | CODE40 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 m | Cum | 208.95 | 208.95 | 3.75 | False | None | None | False | None | False | 783.5625 | 0 |
| 2305581 | 68001 | None | CODE41 | Supplying to work spot rolling, lowering and placing in position RCC
perforated rings in the already excavated pit including loading and
unloading at both the destinations with all lead and lift with appurtenances.,
complete 1200 mmx1250 mm | Each | 9818.55 | 9818.55 | 1.0 | False | None | None | False | None | False | 9818.55 | 0 |
| 2305582 | 68001 | None | CODE42 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 9157.05 | 9157.05 | 0.27 | False | None | None | False | None | False | 2472.4035 | 0 |
| 2305583 | 68001 | None | CODE43 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) | Kgs | 94.5 | 94.5 | 13.25 | False | None | None | False | None | False | 1252.125 | 0 |
| 2305584 | 68001 | None | CODE44 | Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.. | Each | 4057.2 | 4057.2 | 1.0 | False | None | None | False | None | False | 4057.2 | 0 |
| 2305585 | 68001 | None | CODE45 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. | Each | 1019.55 | 1019.55 | 1.0 | False | None | None | False | None | False | 1019.55 | 0 |
| 2305586 | 68001 | None | CODE46 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid | Each | 5255.25 | 5255.25 | 1.0 | False | None | None | False | None | False | 5255.25 | 0 |
| 2305587 | 68001 | None | CODE47 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern | Each | 3712.8 | 3712.8 | 1.0 | False | None | None | False | None | False | 3712.8 | 0 |
| 2305588 | 68001 | None | CODE48 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Surgeon type wash basin of size 660x460 mm with a pair of 15 mm C.P. brass pillar taps with elbow including oper- ated levers | Each | 3555.3 | 3555.3 | 1.0 | False | None | None | False | None | False | 3555.3 | 0 |
| 2305589 | 68001 | None | CODE49 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore | Nos | 554.4 | 554.4 | 2.0 | False | None | None | False | None | False | 1108.8 | 0 |
| 2305590 | 68001 | None | CODE50 | Providing and fixing rectangular high density polyethylene water storage loft tank with cover, conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includes making necessary holes for inlet, outlet & over flow pipes. The base support i/c fittings & fixtures for tank shall be paid separately | Ltr | 8.4 | 8.4 | 1000.0 | False | None | None | False | None | False | 8400.0 | 0 |
| 2305591 | 68001 | None | CODE51 | Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 25mm nominal bore, weighing not less than 62 g | Nos | 117.6 | 117.6 | 2.0 | False | None | None | False | None | False | 235.2 | 0 |
| 2305592 | 68001 | None | CODE52 | Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. 2 HP, Size 65x50 Head 13M, Discharge 462 LPM | Each | 16196.25 | 16196.25 | 1.0 | False | None | None | False | None | False | 16196.25 | 0 |
| 2305593 | 68001 | None | CODE53 | Labour charges for laying and jointing glazed stone ware pipes of 0.6m length and of specified dia., of tested quality conforming to IS 651 of 1965 including caulking with hemp yarn, jointing with CM 1:2 and testing with water etc. complete for: (Rate to include cost of jointing materials and trasportation of pipes from store work site ) Glazed Stone Ware pipe of 200mm dia and 600mm long | m | 93.45 | 93.45 | 6.0 | False | None | None | False | None | False | 560.7 | 0 |
| 2305594 | 68001 | None | CODE54 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 25mm dia, 10 kg/sqcm & class 5 | m | 49.35 | 49.35 | 35.0 | False | None | None | False | None | False | 1727.25 | 0 |
| 2305595 | 68001 | None | CODE55 | Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for: Pipes of SN4, 110mm dia. | m | 284.55 | 284.55 | 20.0 | False | None | None | False | None | False | 5691.0 | 0 |
| 2305596 | 68001 | None | CODE56 | Supply and delivery at site special moulded variety PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments 25mm dia PVC couplers | Each | 13.65 | 13.65 | 7.0 | False | None | None | False | None | False | 95.55 | 0 |
| 2305597 | 68001 | None | CODE57 | Supply and delivery at site special moulded variety PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments 110mm dia PVC couplers | Each | 186.9 | 186.9 | 2.0 | False | None | None | False | None | False | 373.8 | 0 |
| 2305598 | 68001 | None | CODE58 | Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments 25 mm dia PVC Elbows | Each | 17.85 | 17.85 | 6.0 | False | None | None | False | None | False | 107.1 | 0 |
| 2305599 | 68001 | None | CODE59 | Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments 110 mm dia PVC Elbows | Each | 330.75 | 330.75 | 2.0 | False | None | None | False | None | False | 661.5 | 0 |
| 2305600 | 68001 | None | CODE60 | Supply and delivery at site special moulded variety PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments 25 mm dia PVC Tee | Each | 23.1 | 23.1 | 7.0 | False | None | None | False | None | False | 161.7 | 0 |
| 2305601 | 68001 | None | CODE61 | Supply and delivery at site special moulded variety PVC bend as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments 25 mm dia PVC BEND | Each | 26.25 | 26.25 | 6.0 | False | None | None | False | None | False | 157.5 | 0 |
| 2305602 | 68001 | None | CODE62 | Supply and delivery at site special moulded variety PVC bend as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments 110 mm dia PVC BEND | Each | 538.65 | 538.65 | 2.0 | False | None | None | False | None | False | 1077.3 | 0 |
| 2305603 | 68001 | None | CODE63 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc 20 mm nominal dia pipes | m | 391.65 | 391.65 | 20.0 | False | None | None | False | None | False | 7833.0 | 0 |
| 2305604 | 68001 | None | CODE64 | ELECTRICAL: Supplying heavy gauge PVC conduit pipe dia mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 19/20 mm dia 2 mm thick | Mtr | 61.0 | 61.0 | 50.0 | False | None | None | False | None | False | 3050.0 | 0 |
| 2305605 | 68001 | None | CODE65 | Supplying heavy gauge PVC conduit pipe ....... dia mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 25 mm dia 2 mm thick | Mtr | 70.0 | 70.0 | 30.0 | False | None | None | False | None | False | 2100.0 | 0 |
| 2305606 | 68001 | None | CODE66 | Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc. 200 x 90 x 65 mm | Each | 100.0 | 100.0 | 1.0 | False | None | None | False | None | False | 100.0 | 0 |
| 2305607 | 68001 | None | CODE67 | Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc. 200 x 200 x 65 mm | Each | 145.0 | 145.0 | 2.0 | False | None | None | False | None | False | 290.0 | 0 |
| 2305608 | 68001 | None | CODE68 | Supplying and fixing PVC/metal conduit Deep junction box 19/20 mm deep Junction box | Each | 49.0 | 49.0 | 6.0 | False | None | None | False | None | False | 294.0 | 0 |
| 2305609 | 68001 | None | CODE69 | Supplying and fixing PVC/metal conduit Deep junction box 25 mm deep Junction box | Each | 51.0 | 51.0 | 6.0 | False | None | None | False | None | False | 306.0 | 0 |
| 2305610 | 68001 | None | CODE70 | Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete. upto 50 mm conduit in brick wall | Mtr | 26.0 | 26.0 | 20.0 | False | None | None | False | None | False | 520.0 | 0 |
| 2305611 | 68001 | None | CODE71 | Supplying And Fixing Metal Fan Box with Round Hook. | Nos | 163.0 | 163.0 | 40.0 | False | None | None | False | None | False | 6520.0 | 0 |
| 2305612 | 68001 | None | CODE72 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3m from tapping point to out let via switch | Point | 276.0 | 276.0 | 3.0 | False | None | None | False | None | False | 828.0 | 0 |
| 2305613 | 68001 | None | CODE73 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3m upto 6m from tapping point to out let via switch | Point | 386.0 | 386.0 | 2.0 | False | None | None | False | None | False | 772.0 | 0 |
| 2305614 | 68001 | None | CODE74 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6m upto 10m from tapping point to out let via switch box | Point | 567.0 | 567.0 | 1.0 | False | None | None | False | None | False | 567.0 | 0 |
| 2305615 | 68001 | None | CODE75 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmm | Mtr | 26.0 | 26.0 | 180.0 | False | None | None | False | None | False | 4680.0 | 0 |
| 2305616 | 68001 | None | CODE76 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5sqmm | Mtr | 40.0 | 40.0 | 30.0 | False | None | None | False | None | False | 1200.0 | 0 |
| 2305617 | 68001 | None | CODE77 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 3 Module | Each | 152.0 | 152.0 | 1.0 | False | None | None | False | None | False | 152.0 | 0 |
| 2305618 | 68001 | None | CODE78 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 16-18 Module | Each | 270.0 | 270.0 | 2.0 | False | None | None | False | None | False | 540.0 | 0 |
| 2305619 | 68001 | None | CODE79 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A One Way Switch | Each | 88.0 | 88.0 | 8.0 | False | None | None | False | None | False | 704.0 | 0 |
| 2305620 | 68001 | None | CODE80 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator | Each | 313.0 | 313.0 | 4.0 | False | None | None | False | None | False | 1252.0 | 0 |
| 2305621 | 68001 | None | CODE81 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32A DP Switch | Each | 182.0 | 182.0 | 2.0 | False | None | None | False | None | False | 364.0 | 0 |
| 2305622 | 68001 | None | CODE82 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. TV/Telephone socket | Each | 79.0 | 79.0 | 1.0 | False | None | None | False | None | False | 79.0 | 0 |
| 2305623 | 68001 | None | CODE83 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A DP | Each | 1103.0 | 1103.0 | 6.0 | False | None | None | False | None | False | 6618.0 | 0 |
| 2305624 | 68001 | None | CODE84 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. II - Double Door 6 Way SP & N | Each | 2067.0 | 2067.0 | 1.0 | False | None | None | False | None | False | 2067.0 | 0 |
| 2305625 | 68001 | None | CODE85 | Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board. | Each | 8316.0 | 8316.0 | 1.0 | False | None | None | False | None | False | 8316.0 | 0 |
| 2305626 | 68001 | None | CODE86 | Supplying and fixing Electronic Trivector Meter (ETV) suitable for operation LT operation and -CT operated meter in polycarbonate body in class 0.5 accuracy as per IS 14697 and completely wired. | Each | 3942.0 | 3942.0 | 1.0 | False | None | None | False | None | False | 3942.0 | 0 |
| 2305627 | 68001 | None | CODE87 | Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia. | Job | 5325.0 | 5325.0 | 1.0 | False | None | None | False | None | False | 5325.0 | 0 |
| 2305628 | 68001 | None | CODE88 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. 48" Sweep (1200 mm) Regular model | Each | 2085.0 | 2085.0 | 4.0 | False | None | None | False | None | False | 8340.0 | 0 |
| 2305629 | 68001 | None | CODE89 | Extra length of GI pipe of class B 19mm dia for down rod. | Mtr | 173.0 | 173.0 | 4.0 | False | None | None | False | None | False | 692.0 | 0 |
| 2305630 | 68001 | None | CODE90 | Supplying of .....feet -PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI Less than 80. Power Input: 220-240V@ 50/60Hz & Power factor Less than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 20/22 W | Each | 740.0 | 740.0 | 6.0 | False | None | None | False | None | False | 4440.0 | 0 |
| 2305631 | 68001 | None | CODE91 | Supplying & Fixing of 70-150 W lamp holder 2 Pin | Nos | 118.0 | 118.0 | 6.0 | False | None | None | False | None | False | 708.0 | 0 |
| 2305632 | 68001 | None | CODE92 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. | Each | 281.0 | 281.0 | 4.0 | False | None | None | False | None | False | 1124.0 | 0 |
| 2305633 | 68001 | None | CODE93 | Fixing all types and all capacities of 1'x4' / 2'x2' LED Light fittings indoor on the wall / ceiling / rafters / girders with necessary supporting frame, using 2310.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA. | Each | 486.0 | 486.0 | 6.0 | False | None | None | False | None | False | 2916.0 | 0 |
| 2305634 | 68001 | None | CODE94 | Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete. 12" Sweep (300 mm) | Each | 2997.0 | 2997.0 | 1.0 | False | None | None | False | None | False | 2997.0 | 0 |
| 2305635 | 68001 | None | Code 95 | Lowering laying, jointing, testing and commissioning of following
diameters glazed stone ware pipes, conforming to IS 651:1992, (with 5th
revision) in all respects jointing with EPDM rubber rings (seals according
to EN 681 & ASPM 425) . The rubber gasket shall be fixed rigidly with
approved glue to have leak proof joint including conveying of pipe to
work site and rolling and lowering into trenches, laying true to line, level
and perfect linking at joints testing and commissoning including loading
and unloading at both destinations and cuts of pipes wherever necessary
including jointing of GSW pipes and specials, with rubber gaskets
conforming to EN 681 and ASTM C-425 including cleaning the socket
and spigot with soap solution and applying talcum powder for detecting
crack, then applying glue and before inserting of rubber gaskets, jacking
and fixing in perfect condition including the cost of soap solution, talcum
powder and glue etc. and giving necessary hydraulic test to the required
pressure of water head with all lead and lifts including costing of jointing
materials etc., complete. (Contractor will make his own arrangements for
procuring water for testing) with Rubber ring gasket joints 200mm DIa | m | 127.05 | 127.05 | 6.0 | False | None | None | False | None | False | 762.3 | 0 |