createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1706513596469
version5
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee5000.00
emd890000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose12-02-2024 16:00:00
tenderQueryClose05-02-2024 11:30:00
technicalBidOpen13-02-2024 16:30:00
publishedDate29-01-2024 13:38:03
publishedByPostEWHFWD_CE_CEOFF_BNG
publishedByUserKPE16838 - BALEKATTE KUMARASWAMY PAVITHRA
bidValidityPeriod90
noOfCalls1
preBidMeetingDate06-02-2024 11:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonGnanesh Kumar V P
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08029557023
mobileNumber9449843360
tenderSupplierListNone
tenderSchedule
createdTs1706513596498
version8
createdDateNone
modifiedDateNone
tenderNumberEWHFWD/2023-24/BD/WORK_INDENT188
titleUpgradation of infrastructure facilities to the General Hospital and Staff quarters at Bagepalli General Hospital in Chikkaballpura District 2 Construction of New PHC after demolishing the old building at G.Madepalli in Bagepalli taluk Chikkabalalpura District 3 Upgradation of infrastructure facilities to the General Hospital and Staff quarters at Gudibande General Hospital in Chikkaballpura District
descriptionUpgradation of infrastructure facilities to the General Hospital and Staff quarters at Bagepalli General Hospital in Chikkaballpura District 2 Construction of New PHC after demolishing the old building at G.Madepalli in Bagepalli taluk Chikkabalalpura District 3 Upgradation of infrastructure facilities to the General Hospital and Staff quarters at Gudibande General Hospital in Chikkaballpura District
categoryWORKS
categoryTextWorks
ecv59093569.66
deptNameEngineering Wing of Health and Family Welfare Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location3521
locationNameEWHFWD Chief Engineer Office Bengaluru
provisionalAmount62000000.0
groupOverheadTotal0.0
fileNumberAEE/HFWD/KLR/AE3/GH/PHC
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17065135970001NoneNoneBuildings1 Upgradation of infrastructure facilities to the General Hospital and Staff quarters at Bagepalli General Hospital in Chikkaballpura District17237250.7
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
232364668655NoneV2 Item No19.55Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground to the appropriate disposal area as per direction of Engineer-in-charge. ---- etc., complete with all leadSqm44.9744.972730.9FalseNoneNoneFalseNoneFalse122808.5730
232364768655NoneV2 Item No20.89Repairs to plaster in patches of 2.5 m2 and less in walls, ceilings 10 to 20mm thick in cement mortar 1:4 including cutting the patches in proper shape and replastering the surface of the wall including disposal of rubbish with a lead of 50m including curing cost of materials, labour, complete as per specification ---- etc., complete with all leadSqm460.64460.64112.5FalseNoneNoneFalseNoneFalse51822.00
232364868655NoneV1 Item No2.4.1Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all leadCum7783.427783.4293.2816FalseNoneNoneFalseNoneFalse726049.8710720
232364968655NoneV2 Item No8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete with all leadSqm121.54121.541788.95FalseNoneNoneFalseNoneFalse217428.9830
232365068655NoneV2 Item No8.53.2Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 g/L, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. ---- etc., complete with all leadSqm120.32120.324314.1264FalseNoneNoneFalseNoneFalse519075.6884480
232365168655NoneV2 Item No8.64Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :One coats on old work as per specifications and as per directions of Engineer in charge. ---- etc., complete with all leadSqm92.3792.37251.67FalseNoneNoneFalseNoneFalse23246.75790
232365268655NoneV2 Item No8.75.1Finishing walls with Premium Acrylic Smooth exterior paint of required shade : Old work (Two coats applied @ 1.43 l/ 10 m²) over existing cement paint surface including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm134.91134.914268.335FalseNoneNoneFalseNoneFalse575841.074850
232365368655NoneV-1 Item No2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates ---- etc., complete with all leadCum7279.037279.0376.894FalseNoneNoneFalseNoneFalse559713.732820
232365468655NoneV-2 Item No8.3.1Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm430.25430.25650.04FalseNoneNoneFalseNoneFalse279679.710
232365568655NoneV2 Item No15.2Polyurethane based Single Component for Existing Surface Providing and Applying PU based Elastomeric Liquid Applied PU Waterproofing Membrane single component, cold applied, water based acrylic PU dispersion with highly elastic and UV resistant water proofing treatment to the Existing Roof surface/Chajjas/Sunken portion of WC: Bathroom applied @ 1.2 l/per m2, having tensile strength greater than 1.5N/mm2, elongation greater than 300% with solid content not less than 60% in 2 coats including surface preparation, priming the surface with water based acrylic primer @0.1 l/m2, and spreading 60 gsm geotextile between two top coats completely as per specification. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. ---- etc., complete with all leadSqm895.75895.751177.7976FalseNoneNoneFalseNoneFalse1055012.20020
232365668655NoneV2 Item No20.103Repairing door and window frames with available wood to the required size. ---- etc., complete with all leadSqm1185.021185.0270.8FalseNoneNoneFalseNoneFalse83899.4160
232365768655NoneV2 Item No20.104Repairing and fixing shutters (panelled or glazed) to doors, windows, ventilators and cupboards. ---- etc., complete with all leadSqm1185.021185.0270.8FalseNoneNoneFalseNoneFalse83899.4160
232365868655NoneV2 Item No20.107Providing and fixing plain rolled glass 4mm thick with teakwood beading of 10mm thick. ---- etc., complete with all leadSqm1394.061394.063.4FalseNoneNoneFalseNoneFalse4739.8040
232365968655NoneV2 Item No12.58Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. ---- etc., complete with all leadSqm145.85145.85150.0FalseNoneNoneFalseNoneFalse21877.50
232366068655NoneV2 Item No12.55.1Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. -do- with both side prelam ---- etc., complete with all leadSqm2875.642875.6430.0FalseNoneNoneFalseNoneFalse86269.20
232366168655NoneV2 Item No11.25.2Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge. ---- etc., complete with all leadKg165.29165.29467.56FalseNoneNoneFalseNoneFalse77282.99240
232366268655NoneV2 Item No13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter ---- etc., complete with all leadm353.68353.68508.0FalseNoneNoneFalseNoneFalse179669.440
232366368655NoneV2 Item No9.17.2Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm ---- etc., complete with all leadSqm1428.11428.1887.4832FalseNoneNoneFalseNoneFalse1267414.757920
232366468655NoneV2 Item No9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. ---- etc., complete with all leadSqm3466.323466.32286.3348FalseNoneNoneFalseNoneFalse992528.0439360
232366568655NoneV2 Item No9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. ---- etc., complete with all leadm1080.491080.49194.76FalseNoneNoneFalseNoneFalse210436.23240
232366668655NoneV2 Item No9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete with all leadm1761.111761.11611.52FalseNoneNoneFalseNoneFalse1076953.98720
232366768655NoneV2 Item No8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadm357.33357.33677.43FalseNoneNoneFalseNoneFalse242066.06190
232366868655NoneV2 Item No12.9Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all leadSqm8184.58184.580.1FalseNoneNoneFalseNoneFalse655578.450
232366968655NoneV2 Item No12.85Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all leadSqm6950.876950.8711.52FalseNoneNoneFalseNoneFalse80074.02240
232367068655NoneV2 Item No11.35.2.3Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-incharge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications. ---- etc., complete with all leadKg707.36707.361701.0FalseNoneNoneFalseNoneFalse1203219.360
232367168655NoneV2 Item No11.36.2Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer- in-charge: Pre-laminated particle board with decorative lamination on both side including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Aluminium sections shall be smooth, rust free, straight, mitred and jointe mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-incharge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications. ---- etc., complete with all leadSqm1194.741194.7454.0FalseNoneNoneFalseNoneFalse64515.960
232367268655NoneV2 Item No11.37.2Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasketnetc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/m²) including cost of materials, labour, usage charges of machinery complete as per specifications. ---- etc., complete with all leadSqm1423.231423.2359.4FalseNoneNoneFalseNoneFalse84539.8620
232367368655NoneV1 Item No 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Columns ---- etc., complete with all leadCum14050.0514050.053.94FalseNoneNoneFalseNoneFalse55357.1970
232367468655NoneV1 Item No 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Lintel Beam ---- etc., complete with all leadCum11971.1511971.1512.96FalseNoneNoneFalseNoneFalse155146.1040
232367568655NoneV1 Item No 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Chajja ---- etc., complete with all leadCum10876.2310876.230.86FalseNoneNoneFalseNoneFalse9353.55780
232367668655NoneV1 Item No 2.11 aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification ---- etc., complete with all leadTonne109781.63109781.631.6732FalseNoneNoneFalseNoneFalse183686.6233160
232367768655NoneV1 Item No 2.1.4Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all leadCum10857.3710857.372.96FalseNoneNoneFalseNoneFalse32137.81520
232367868655NoneV2 Item No 6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete with all leadSqm1607.631607.630.72FalseNoneNoneFalseNoneFalse1157.49360
232367968655NoneV2 Item No 8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm258.94258.9460.0FalseNoneNoneFalseNoneFalse15536.40
232368068655NoneV2 Item No 8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge... ( Inside) ---- etc., complete with all leadSqm382.89382.89152.11FalseNoneNoneFalseNoneFalse58241.39790
232368168655NoneV2 Item No 8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete with all leadSqm122.72122.72203.11FalseNoneNoneFalseNoneFalse24925.65920
232368268655NoneV2 Item No 8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. ( Outside) ---- etc., complete with all leadSqm360.8360.8172.72FalseNoneNoneFalseNoneFalse62317.3760
232368368655NoneV2 Item No 8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. ---- etc., complete with all leadm63.8163.8132.8FalseNoneNoneFalseNoneFalse2092.9680
232368468655NoneV2 Item No 8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm155.85155.85203.11FalseNoneNoneFalseNoneFalse31654.69350
232368568655NoneV2 Item No 8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm191.44191.44172.72FalseNoneNoneFalseNoneFalse33065.51680
232368668655NoneV2 Item No 8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm65.0465.041.89FalseNoneNoneFalseNoneFalse122.92560
232368768655NoneV2 Item No 8.4Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm141.13141.131.89FalseNoneNoneFalseNoneFalse266.73570
232368868655NoneV2 Item No 15.1Providing and Applying PU based Elastomeric Liquid Applied PU Waterproofing Membrane single component, cold applied, water based acrylic PU dispersion with highly elastic and UV resistant water proofing treatment to the Existing Roof surface/Chajjas/Sunken portion of WC:Bathroom applied @ 1.2L/per m2,having tensile strength greater than 1.5N/mm2, elongation greater than 300% with solid content not less than 60% in 2 coats including surface preparation, priming the surface with water based acrylic primer @0.1 L/m2, and spreading 60 gsm geotextile between two top coats completely as per specification. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. ---- etc., complete with all leadSqm1002.621002.6248.85FalseNoneNoneFalseNoneFalse48977.9870
232368968655NoneV3 Item No 2.5(ii)AClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer.A In area of light jungle A.In area of light jungle ---- etc., complete with all leadSqm477.65477.652.45FalseNoneNoneFalseNoneFalse1170.24250
232369068655NoneV1 Item No 1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.In all kinds of soil upto 300 mm depth ---- etc., complete with all leadCum115.46115.4660.03FalseNoneNoneFalseNoneFalse6931.06380
232369168655NoneV1 Item No 1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work, In all types of soil upto 3.00 m depth ---- etc., complete with all leadCum123.97123.97110.32FalseNoneNoneFalseNoneFalse13676.37040
232369268655NoneV1 Item No 1.15.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work, In ordinary/soft rock without blasting upto 1.5 m depth but not exceeding 3 m ---- etc., complete with all leadCum441.19441.1912.116FalseNoneNoneFalseNoneFalse5345.458040
232369368655NoneV2 Item No 4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. ---- etc., complete with all leadCum143.42143.4215.0FalseNoneNoneFalseNoneFalse2151.30
232369468655NoneV-1 Item No 2.2.3Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all leadCum8448.428448.4217.1459FalseNoneNoneFalseNoneFalse144855.7644780
232369568655NoneV1 Item No 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all leadCum13244.5313244.530.48FalseNoneNoneFalseNoneFalse6357.37440
232369668655NoneV1 Item No 1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete with all leadCum323.3323.38.946FalseNoneNoneFalseNoneFalse2892.24180
232369768655NoneV1 Item No 1.8Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. ---- etc., complete with all leadCum576.1576.130.0FalseNoneNoneFalseNoneFalse17283.00
232369868655NoneV1 Item No 2.11 aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification ---- etc., complete with all leadTonne108726.04108726.043.5611FalseNoneNoneFalseNoneFalse387184.3010440
232369968655NoneV2 Item No 6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete with all leadSqm1592.171592.1742.65FalseNoneNoneFalseNoneFalse67906.05050
232370068655NoneV2 Item No 6.34Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete with all leadSqm1341.81341.86.0FalseNoneNoneFalseNoneFalse8050.80
232370168655NoneV2 Item No 11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- etc., complete with all leadKg204.19204.19113.399FalseNoneNoneFalseNoneFalse23154.941810
232370268655NoneV2 Item No 11.5.1Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete with all leadSqm5442.565442.566.3FalseNoneNoneFalseNoneFalse34288.1280
232370368655NoneV2 Item No 8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge... ( Inside) ---- etc., complete with all leadSqm379.2379.257.35FalseNoneNoneFalseNoneFalse21747.120
232370468655NoneV2 Item No 8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm154.36154.3657.35FalseNoneNoneFalseNoneFalse8852.5460
232370568655NoneV2 Item No 8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm189.6189.645.35FalseNoneNoneFalseNoneFalse8598.360
232370668655NoneV2 Item No 8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm60.7760.77129.7FalseNoneNoneFalseNoneFalse7881.8690
232370768655NoneV2 Item No 8.43Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade :Two coats on new work including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm114.25114.25119.699FalseNoneNoneFalseNoneFalse13675.610750
232370868655NoneV2 Item No 7.38Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal,complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. :(P.No.26, I.No. 7.38 of PWD SR 2023-24 Vol-2) ---- etc., complete with all leadSqm690.35690.3518.816FalseNoneNoneFalseNoneFalse12989.62560
232370968655NoneV3 Item No 2.5(ii)AClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer.A In area of light jungle ---- etc., complete with all leadSqm477.65477.650.36FalseNoneNoneFalseNoneFalse171.9540
232371068655NoneV-1 Item No 2.2.3Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Raft ---- etc., complete with all leadCum7925.077925.074.1119FalseNoneNoneFalseNoneFalse32587.0953330
232371168655NoneV-1 Item No 2.2.3Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates TOP SLAB ---- etc., complete with all leadCum9196.079196.073.0839FalseNoneNoneFalseNoneFalse28359.7602730
232371268655NoneV-2 Item No 15.1Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/ Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. ---- etc., complete with all leadSqm992.98992.98101.56FalseNoneNoneFalseNoneFalse100847.04880
232371368655NoneV-2 Item No 8.4Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm139.77139.7741.12FalseNoneNoneFalseNoneFalse5747.34240
232371468655None18-19 SR Item No XXIV (624)C. I Manhole covers 24" x 24" ---- etc., complete with all leadNos2575.02575.06.0FalseNoneNoneFalseNoneFalse15450.00
232371568655NoneV-5 Item No 12.4Geophysical investigation of site for sinking Borewell for supplying drinking water to Habitation either through the Handpump, MWS or PWSS by vertical sounding by adopting veener sounding by adopting veener or schlumbergers's including reconassiance of survey of Geological formation,geophysical investigation of existing ground water in the vicinity quality, quantity and acceptability of the user including the location of site,recommended department of casing pipe required to seal the top and consolidated formation including an extra depth of 1.00Mtr in consolidated formation including an extra depth of drilling required to cover full depth of occupier proposed to trap probable yield and other information required including transportation of instrument and accessories to work site engaging technical personnel labour required etc complete as directed by Engineer in charge ---- etc., complete with all leadEach6427.046427.041.0FalseNoneNoneFalseNoneFalse6427.040
232371668655NoneV-5 Item No 12.1Sinking of borewell of 165 mm dia clear using super fast hydraulic of capasity 300 PSIG & above 1100 CMF & above in all strata including over burden upto 20 M fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle crew charges and cost of consumables, etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes) for piped water supply schemes Upto 50 Mtrs ---- etc., complete with all leadRmtr449.7449.750.0FalseNoneNoneFalseNoneFalse22485.00
232371768655NoneV-5 Item No 12.1Sinking of borewell of 165 mm dia clear using super fast hydraulic of capasity 300 PSIG & above 1100 CMF & above in all strata including over burden upto 20 M fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle crew charges and cost of consumables, etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes) for piped water supply schemes Above 50 Mtrs and upto 100 Mtr. ---- etc., complete with all leadRmtr563.95563.9550.0FalseNoneNoneFalseNoneFalse28197.50
232371868655NoneV-5 Item No 12.1Sinking of borewell of 165 mm dia clear using super fast hydraulic of capasity 300 PSIG & above 1100 CMF & above in all strata including over burden upto 20 M fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle crew charges and cost of consumables, etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes) for piped water supply schemes Above100 Mtrs. and upto 150 Mtr. ---- etc., complete with all leadRmtr599.19599.1950.0FalseNoneNoneFalseNoneFalse29959.50
232371968655NoneV-5 Item No 12.1Sinking of borewell of 165 mm dia clear using super fast hydraulic of capasity 300 PSIG & above 1100 CMF & above in all strata including over burden upto 20 M fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle crew charges and cost of consumables, etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes) for piped water supply schemes Above150 Mtrs. and upto 200 Mtr. ---- etc., complete with all leadRmtr695.21695.2150.0FalseNoneNoneFalseNoneFalse34760.50
232372068655NoneV-5 Item No 12.1Sinking of borewell of 165 mm dia clear using super fast hydraulic of capasity 300 PSIG & above 1100 CMF & above in all strata including over burden upto 20 M fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle crew charges and cost of consumables, etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes) for piped water supply schemes Above200 Mtrs. and upto 250 Mtr. ---- etc., complete with all leadRmtr815.53815.5350.0FalseNoneNoneFalseNoneFalse40776.50
232372168655NoneV-5 Item No 12.1Sinking of borewell of 165 mm dia clear using super fast hydraulic of capasity 300 PSIG & above 1100 CMF & above in all strata including over burden upto 20 M fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle crew charges and cost of consumables, etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes) for piped water supply schemes Above250 Mtrs. and upto 300 Mtr. ---- etc., complete with all leadRmtr899.4899.435.0FalseNoneNoneFalseNoneFalse31479.00
232372268655NoneV-5 Item No 12.32Supply Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. ---- etc., complete with all leadRmtr2349.372349.3725.0FalseNoneNoneFalseNoneFalse58734.250
232372368655NoneV-5 Item No 13.28Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments ---- etc., complete with all leadRmtr668.47668.47200.0FalseNoneNoneFalseNoneFalse133694.00
232372468655NoneV-5 Item No 12.33Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments ---- etc., complete with all leadNos182.31182.311.0FalseNoneNoneFalseNoneFalse182.310
232372568655NoneV-5 Item No 12.34Providing and laying at site of work MS casing caps as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge ---- etc., complete with all leadNos199.33199.331.0FalseNoneNoneFalseNoneFalse199.330
232372668655NoneLeast Quotation RateProviding NP/CP 50mm dia Waste Unions conforming to ISI specifications and fixing them in position as per directions (Rates includes cost of materials fixtures and conveyance to work spot etc complete) ---- etc., complete with all leadNos247.8247.81.0FalseNoneNoneFalseNoneFalse247.80
232372768655NoneV-5 Item No 13.13.6Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 5.00 HP - 90 LPM @ 110 m = 10 STG Outlet Dia - 2.00" ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete with all leadEach39059.3139059.311.0FalseNoneNoneFalseNoneFalse39059.310
232372868655NoneV-5 Item No 13.23.2Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter Up to 3 to 6 HP ---- etc., complete with all lead& lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete with all leadEach11269.011269.01.0FalseNoneNoneFalseNoneFalse11269.00
232372968655NoneV-5 Item No 13.29Supply and delivery at site 50mm(2”) dia heavy duty CI adopter set complete suitable for uPVC Column pipes for Submersible pumpsets. complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete with all leadSet1883.871883.871.0FalseNoneNoneFalseNoneFalse1883.870
232373068655NoneV-5 Item No 13.31Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets. ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete with all leadJob48.6248.62100.0FalseNoneNoneFalseNoneFalse4862.00
232373168655NoneV-5 Item No 13.32Labour charges for Erection, Electrification and commissioning works of Pump sets including aligning and balancing with all necessary erection of materials and labour including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges, tools and equipments etc., involved in the job. as per specifications, with testing of as per instructions of engineer incharge of work ---- etc., complete with all lead& lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete with all leadJob7900.17900.11.0FalseNoneNoneFalseNoneFalse7900.10
232373268655NoneV-5 Item No 13.33Labour charges for Erection of outdoor type panel board and meter board units with all necessary materials and labour tools and equipments including providing cement concrete foundation bed etc., complete. as per specifications, with testing of as per instructions of engineer incharge of work ---- etc., complete with all lead& lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete with all leadJob1640.791640.791.0FalseNoneNoneFalseNoneFalse1640.790
232373368655NoneV-6 Item No 2.6.2Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirmining to table 3 class 5 of IS:8130-1984 and virgin grade PVC insulation and sheathed suitable for working voltage upto 1100Volts as per IS-694:1990 & confirming to GTP of GROUP-A(12/2.10) 3C x 6 mm ---- etc., complete with all leadRmtr204.19204.19259.0FalseNoneNoneFalseNoneFalse52885.210
232373468655NoneV-6 Item No 5.42.2Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG ---- etc., complete with all leadSq CM0.520.5230000.0FalseNoneNoneFalseNoneFalse15600.00
232373568655NoneV-6 Item No 5.44.4Supply and Installation I Fixing I Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase I Three Phase Energy Meter in suitable base plate and having a provision for Fuse I MCB cutout with suitable transparent hinged flap opening for operating MCB along with 10 complete tamper proof SEALING facility. (50/6.42) 600mmx600mmx170mm. ---- etc., complete with all leadEach17647.6117647.611.0FalseNoneNoneFalseNoneFalse17647.610
232373668655NoneV-6 Item No 5.6.6Supplying and fixing polished wood board made of not less than 15mm thick plank on both sides with planks made out of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws etc. - 500 x 500 x 65 mm (20" x 20" x 2.5") etc., complete as per directions of the Engineer-in-charge ---- etc., complete with all leadEach396.38396.381.0FalseNoneNoneFalseNoneFalse396.380
232373768655NoneLeast Quotation Rate.Supplying and fixing miniature circuit breakers/Isolators on existing MCB distribution boards using necessary fixing materials and wiring complete as directed by the Engineer-in-charge - 5 to 30 Amps Triple and Neutral ---- etc., complete with all leadEach2023.72023.71.0FalseNoneNoneFalseNoneFalse2023.70
232373868655NoneLeast Quotation Rate.Supplying and fixing TPST with neutral link switches rewirable fuse type - Havels / Standard / Indo-Asian Crescent - 30 to 35 Amps, etc., complete as per directions of the Engineer-in-charge ---- etc., complete with all leadEach2124.02124.01.0FalseNoneNoneFalseNoneFalse2124.00
232373968655NoneLeast Quotation Rate.Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery (48/6.35) ---- etc., complete with all leadEach472.0472.01.0FalseNoneNoneFalseNoneFalse472.00
232374068655NoneV-3 Item No 3.1Removal of Unserviceable Soil with Disposal upto a suitable distance as directed by the Engineer incharge of work ---- etc., complete with all leadCum103.31103.3163.0FalseNoneNoneFalseNoneFalse6508.530
232374168655NoneV-3 Item No 6.6Plain Cement Pavement Quality M30 grade Concrete (RMC) with OPC & GGBS laid without Paver Construction of un-reinforced plain cement concrete pavement using RMC M-30 grade with OPC @ 270 kg/m3 and GGBS@ 90kg/m3 (75:25 proportion) as per approved mix design procedure and thickness as per design, over a prepared sub base. The superplastisiser confirming to IS 9103-1999 Reaffirmed-2008, Coarse aggregates and Fine aggregate confirming to IS:383-2016, transported to site, laid in approved fixed side form work (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the form work). Spreading the concrete with shovels, rackers and compacted using needle, suitable plate vibrator and finished in a continuous operation including provision of separation membrane and Hessian cloth finishing to lines and grades complete including cost of all materials, labour, all lead & lift, loading charges as per specification & direction of Engineer - incharge of the work. (Groove cutting shall be paid seperately ---- etc., complete with all leadCum8233.128233.124.725FalseNoneNoneFalseNoneFalse38901.4920
232374268655NoneV-3 Item No 6.8.1Providing and laying 60mm thick factory made precast M -30 grade Cement Concrete Paver Block as per IRC SP 63:2018 & IS 15658 for Cycle Tracks & Pedestrian Footpaths of approved shape and colour, laid in required pattern and including over 30mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-incharge. (WMM/WBM Base to be paid separately if necessary as per relevant technical specification) ---- etc., complete with all leadSqm1298.051298.05210.0FalseNoneNoneFalseNoneFalse272590.50
232374368655NoneV-1 Item No 1.4.1Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m ---- etc., complete with all leadCum294.13294.13190.0FalseNoneNoneFalseNoneFalse55884.70
232374468655NoneV-1 Item No 1.1Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour complete as per specifications ---- etc., complete with all leadCum194.46194.46190.0FalseNoneNoneFalseNoneFalse36947.40
232374568655NoneV-2 Item No 13.31.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 20 mm nominal dia Pipes ---- etc., complete with all leadm294.13294.13380.0FalseNoneNoneFalseNoneFalse111769.40
232374668655NoneV-2 Item No 13.31.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 25 mm nominal dia Pipes ---- etc., complete with all leadm386.5386.5228.0FalseNoneNoneFalseNoneFalse88122.00
232374768655NoneV-2 Item No 13.33.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 20 mm nominal dia Pipes ---- etc., complete with all leadm263.74263.74570.0FalseNoneNoneFalseNoneFalse150331.80
232374868655NoneV-2 Item No 13.33.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 25 mm nominal dia Pipes ---- etc., complete with all leadm359.76359.76760.0FalseNoneNoneFalseNoneFalse273417.60
232374968655NoneV-2 Item No 13.63Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0 cm X 4.0 cm with all fitting arrangements & all necessary accessories complete ---- etc., complete with all leadEach296.56296.5660.0FalseNoneNoneFalseNoneFalse17793.60
232375068655NoneV-2 Item No 13.64.1Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75mm nominal dia pipes ---- etc., complete with all leadm351.25351.25380.0FalseNoneNoneFalseNoneFalse133475.00
232375168655NoneV-2 Item No 13.64.2Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 110mm nominal dia pipes ---- etc., complete with all leadm467.93467.93380.0FalseNoneNoneFalseNoneFalse177813.40
232375268655NoneV-2 Item No 13.64.3Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 150mm nominal dia pipes ---- etc., complete with all leadm933.43933.43380.0FalseNoneNoneFalseNoneFalse354703.40
232375368655NoneV-2 Item No 13.59Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete ---- etc., complete with all leadEach267.39267.3960.0FalseNoneNoneFalseNoneFalse16043.40
232375468655NoneV-2 Item No 13.22.1.1Providing and fixing PTMT grating of approved quality and colour. Circular type 100 mm nominal dia ---- etc., complete with all leadNos49.8349.8360.0FalseNoneNoneFalseNoneFalse2989.80
232375568655NoneV-2 Item No 13.5.2Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 20 mm nominal bore ---- etc., complete with all leadNos381.64381.6420.0FalseNoneNoneFalseNoneFalse7632.80
232375668655NoneV-2 Item No 13.3.2 Providing and fixing brass stop cock of approved quality 20 mm nominal bore ---- etc., complete with all leadNos370.7370.740.0FalseNoneNoneFalseNoneFalse14828.00
232375768655NoneV-2 Item No 13.4.1Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore ---- etc., complete with all leadNos667.25667.2540.0FalseNoneNoneFalseNoneFalse26690.00
232375868655NoneV-2 Item No 13.2.2Providing and fixing brass bib cock of approved quality : 20 mm nominal bore ---- etc., complete with all leadNos370.7370.760.0FalseNoneNoneFalseNoneFalse22242.00
232375968655NoneV-2 Item No 13.53Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5 ---- etc., complete with all leadNos6857.296857.2950.0FalseNoneNoneFalseNoneFalse342864.50
232376068655NoneV-2 Item No 13.53Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) With common burnt clay (non modular) bricks of class designation 3.5 ---- etc., complete with all leadNos12841.9212841.9210.0FalseNoneNoneFalseNoneFalse128419.20
232376168655NoneV-2 Item No 13.53.1Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) With common burnt clay (non modular) bricks of class designation 3.5 Extra for depth for manholes : Size 90x80 cm With common burnt clay (non modular) bricks of class designation ---- etc., complete with all leadNos11225.4311225.435.0FalseNoneNoneFalseNoneFalse56127.150
232376268655NoneV-2 Item No 14.28.2.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40mm dia pipes, From wash basin waste lines ---- etc., complete with all leadEach111.82111.8221.0FalseNoneNoneFalseNoneFalse2348.220
232376368655NoneV-2 Item No 14.32.3Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Oval shape 450x350 mm (outer dimensions) ---- etc., complete with all leadEach1295.621295.6220.0FalseNoneNoneFalseNoneFalse25912.40
232376468655NoneV-2 Item No 14.40.2600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. ---- etc., complete with all leadEach602.84602.8420.0FalseNoneNoneFalseNoneFalse12056.80
232376568655NoneV-2 Item No 14.2.1Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid ---- etc., complete with all leadEach5880.115880.1112.0FalseNoneNoneFalseNoneFalse70561.320
232376668655NoneV-2 Item No 20.44.2Providing & fixing White vitreous china water closet squatting pan (Indian type) along with "S" or "P" trap including dismantling of old WC seat and "S" or "P" trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge. Orissa pattern W.C Pan of size 580x440 mm ---- etc., complete with all leadEach4311.024311.025.0FalseNoneNoneFalseNoneFalse21555.10
232376768655NoneV-2 Item No 14.10.1.3Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040 mm bowl depth 200 mm ---- etc., complete with all leadEach6002.866002.865.0FalseNoneNoneFalseNoneFalse30014.30
232376868655NoneV-2 Item No 14.7.7White Vitreous China Flat back wash basin size 450x 300 mm with single 15mm C.P. brass pillar tap ---- etc., complete with all leadEach2551.122551.1210.0FalseNoneNoneFalseNoneFalse25511.20
232376968655NoneV-2 Item No 13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank. ---- etc., complete with all leadLtr10.9410.946000.0FalseNoneNoneFalseNoneFalse65640.00
232377068655NoneV6 Item No 1.8.2Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends,junction box,elbows,screws at an interval of 300 mm as required. 25mm ---- etc., complete with all leadm42.5442.54240.0FalseNoneNoneFalseNoneFalse10209.60
232377168655NoneV6 Item No 1.9.2Supplying PVC flexible conduit pipe....mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddle satan interval of 300mm usig NF screws and on either end of the pipe terminated completely 25mm ---- etc., complete with all leadm26.7426.7460.0FalseNoneNoneFalseNoneFalse1604.40
232377268655NoneV6 Item No 2.2.1Supplying and wiring adopting loop system in existing PVC Conduit/casing capping casing capping using 2x1.5Sqmm (Phase&Neutral) & 1x1.0sqmm (Earth wire) FRLS multistrand PVC insulated copper wire(confirming to IS-694 and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch box ---- etc., complete with all leadPoint326.94326.9448.0FalseNoneNoneFalseNoneFalse15693.120
232377368655NoneV6 Item No 2.2.2Supplying and wiring adopting loop system in existing PVC Conduit/casing capping casing capping using 2x1.5Sqmm (Phase&Neutral) & 1x1.0sqmm (Earth wire) FRLS multistrand PVC insulated copper wire (confirming to IS-694 and latest amendments) without control switch shall be fixed on the existing plastic sheet/gangbox, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3 Mtr upto 6Mtr from tapping point to outlet via switch box ---- etc., complete with all leadPoint460.64460.6448.0FalseNoneNoneFalseNoneFalse22110.720
232377468655NoneV6 Item No 2.2.3Supplying and wiring adopting loop system in existing PVC Conduit/casing capping casing capping using 2x1.5Sqmm (Phase&Neutral) & 1x1.0sqmm (Earth wire) FRLS multistrand PVC insulated copper wire (confirming to IS-694 and latest amendments) without control switch shall be fixed on the existing plastic sheet/gangbox, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr upto 10Mtr from tapping point to outlet via switch box ---- etc., complete with all leadPoint674.55674.5548.0FalseNoneNoneFalseNoneFalse32378.40
232377568655NoneV6 Item No 2.3.1Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multi strand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 1 mm2 ---- etc., complete with all leadm23.0923.091800.0FalseNoneNoneFalseNoneFalse41562.00
232377668655NoneV6 Item No 2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multi strand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 2.5 mm2 ---- etc., complete with all leadm51.0551.051200.0FalseNoneNoneFalseNoneFalse61260.00
232377768655NoneV6 Item No 2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multi strand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 4 mm2 ---- etc., complete with all leadm76.5776.57600.0FalseNoneNoneFalseNoneFalse45942.00
232377868655NoneV6 Item No 2.3.5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multi strand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 6 mm2 ---- etc., complete with all leadm111.82111.82120.0FalseNoneNoneFalseNoneFalse13418.40
232377968655NoneV6 Item No 3.14.1Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. 6A SP Switch ---- etc., complete with all leadNos66.8566.85120.0FalseNoneNoneFalseNoneFalse8022.00
232378068655NoneV6 Item No 3.14.2Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. 6A Two Way Switch ---- etc., complete with all leadNos85.0885.0812.0FalseNoneNoneFalseNoneFalse1020.960
232378168655NoneV6 Item No 3.14.3Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. 6A Three Way 5 Pin Socket ---- etc., complete with all leadNos85.0885.0824.0FalseNoneNoneFalseNoneFalse2041.920
232378268655NoneV6 Item No 3.14.7Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. 6A Batten Holder ---- etc., complete with all leadNos89.9489.9448.0FalseNoneNoneFalseNoneFalse4317.120
232378368655NoneV6 Item No 3.14.10Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. 16A SP Switch ---- etc., complete with all leadNos159.22159.2212.0FalseNoneNoneFalseNoneFalse1910.640
232378468655NoneV6 Item No 3.14.12Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. 16A Three Way 5 Pin Socket ---- etc., complete with all leadNos139.77139.7712.0FalseNoneNoneFalseNoneFalse1677.240
232378568655NoneV6 Item No 3.14.14Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. 32A Bakelite DP ---- etc., complete with all leadNos281.97281.9724.0FalseNoneNoneFalseNoneFalse6767.280
232378668655NoneV6 Item No 3.14.16Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. Electronic stepped regulator. ---- etc., complete with all leadNos341.53341.5336.0FalseNoneNoneFalseNoneFalse12295.080
232378768655NoneV6 Item No 3.12.2Supplying......way plastic gang box and fixing using necessary wooden/ rawl/phill plugs and screws. 2 to 4 Way Gang Box ---- etc., complete with all leadNos38.8938.8948.0FalseNoneNoneFalseNoneFalse1866.720
232378868655NoneV6 Item No 3.9Supplying and fixing hylum plastic sheet 3 mm thick with necessary nitches for fixing switches, regulators etc., and fixing on existing wood or metal box using N. F. screws. ---- etc., complete with all leadSq CM0.430.4327000.0FalseNoneNoneFalseNoneFalse11610.00
232378968655NoneV6 Item No 3.10.2Supplying 4 mm thick white plastic plate and covering for junction boxes of size......mm conduit using necessary machine screws. 80/90 mm ---- etc., complete with all leadNos18.2318.2354168.0FalseNoneNoneFalseNoneFalse987482.640
232379068655NoneV6 Item No 4.3Supply and erection of 14 Feet Height Street Light Pole 14 Feet Height Street Light Pole on suitable cement concrete foundation with 2.5 Feet height dia 5mm cast iron decorative round pedestal as per design weighing not less than 37Kgs, the pedestal shall be fitted with Class 'C' G.I.Pipe 7 Feet height 75mm outer dia and 7feet height top piece outer dia of 65mm fixed by measure of threading/welding/coupling complete. (excluding foundation). ---- etc., complete with all leadNos25037.2425037.2410.0FalseNoneNoneFalseNoneFalse250372.40
232379168655NoneV6 Item No 6.1Supplying exhaust fan of 1440 RPM of 300mm (12inches) size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. ---- etc., complete with all leadEach1813.381813.3812.0FalseNoneNoneFalseNoneFalse21760.560
232379268655NoneV6 Item No 6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc,for operation on 230V, 50cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48inches Sweep (1200 mm) Regular model ---- etc., complete with all leadEach3626.753626.7524.0FalseNoneNoneFalseNoneFalse87042.00
232379368655NoneV6 Item No 11.3.1Supplying of..... feet-PVC Batten with integrated LEDtube.... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than80. Power Input:220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 2feet - 9/10 W ---- etc., complete with all leadEach669.69669.6924.0FalseNoneNoneFalseNoneFalse16072.560
232379468655NoneV6 Item No 11.3.3Supplying of..... feet-PVC Batten with integrated LEDtube.... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than80. Power Input:220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 36/40 W ---- etc., complete with all leadEach1542.341542.3436.0FalseNoneNoneFalseNoneFalse55524.240
232379568655NoneV6 Item No 12.41Supplying & Fixing of 250W/400W High Pressure Sodium Vapour tubular Lamp with Xenon filled gas with luminous efficiency of greater than 140 lumen/W or initial lumens of greater than 55000 lumens & avg rated life greater than 26000hrs. & minimum starting temperature of deg C & Hot re strike time less than 60 Sec with CCT 2000K. Operating voltage range from 180V to 265V, 50Hz AC power Supply ---- etc., complete with all leadEach2156.122156.1210.0FalseNoneNoneFalseNoneFalse21561.20
232379668655NoneV6 Item No 11.15Supplying and fixing of LED Bulk head of 10W with IP65 protection and IK 08 impact resistance suitable for surface and wall mounting applications. ---- etc., complete with all leadEach1023.371023.3712.0FalseNoneNoneFalseNoneFalse12280.440
232379768655NoneV6 Item No 12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cut outs and other equipment' s on the meter board using 40mm dia 2.90mm thick GI pipe 2.5m long buried in a pit. The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia ---- etc., complete with all leadNos4266.054266.0512.0FalseNoneNoneFalseNoneFalse51192.60
232379868655NoneV6 Item No 13.1.2Supplying and Fixing of mm dia class A GI pipe bracket upto 2ms long bent at suitable angle and fixing to this bracket street light fitting of all capacities to GIor GIorrailor RC pole/ wall using suitable clamps, bolts, and nuts and wiring using suitable capacity wires. Using 32mm dia G.I.Pipe ---- etc., complete with all leadEach1270.091270.0910.0FalseNoneNoneFalseNoneFalse12700.90
232379968655NoneV6 Item No 13.5Fixing halogen/metal halide/SVL/IL/LED flood light fitting over existing pole/wall ceiling including clamps,bolts,nuts and wiring using suitable capacity wires. ---- etc., complete with all leadEach196.89196.8910.0FalseNoneNoneFalseNoneFalse1968.90
232380068655NoneV6 Item No 13.7.1Fixing all types and all capacities of fluorescent/false ceiling/spotlight/CFL/LED fittings indoor on the wall/ceiling/rafters/girdersusing23/0.0076 inch twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall/ ceiling / Rafter / Girders ---- etc., complete with all leadEach148.28148.28190.0FalseNoneNoneFalseNoneFalse28173.20
232380168655NoneV6 Item No 13.1Fixing a ceiling/Wall mounting fan of all capacities and all types to the existing S hook with fan regulator to the existing board together with supplying and fixing 5A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. ---- etc., complete with all leadEach207.83207.8376.0FalseNoneNoneFalseNoneFalse15795.080
232380268655NoneV6 Item No 13.14Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5A.ceiling rose withs ufficient lengthof23/0.0076 inch PVC insulated twin core wire. ---- etc., complete with all leadEach597.98597.9812.0FalseNoneNoneFalseNoneFalse7175.760
17065135970001NoneNoneBuildings2 Construction of New PHC after demolishing the old building at G.Madepalli in Bagepalli taluk Chikkabalalpura District28436406.68
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
232380368656NoneV2 Item No 19.3Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. ---- etc., complete with all leadCum2862.682862.6818.59FalseNoneNoneFalseNoneFalse53217.22120
232380468656NoneV2 Item No 19.7.3Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. In cement mortar ---- etc., complete with all leadCum1214.221214.2291.51FalseNoneNoneFalseNoneFalse111113.27220
232380568656NoneV2 Item No 19.9.2Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineerin- charge. In cement mortar ---- etc., complete with all leadCum1987.121987.1275.84FalseNoneNoneFalseNoneFalse150703.18080
232380668656NoneV2 Item No 19.12.1Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking to the appropriate disposal area as per direction of Engineer-in-charge. 19.12.1 Of area 3 m² and below ---- etc., complete with all leadCum283.2283.233.84FalseNoneNoneFalseNoneFalse9583.4880
232380768656NoneV2 Item No 19.22.1Dismantling tile work in floors and roofs laid in cement mortar including stacking material to the appropriate disposal area as per direction of Engineer-in-charge.For thickness of tiles 10 mm to 25 mm ---- etc., complete with all leadSqm56.6456.6488.0FalseNoneNoneFalseNoneFalse4984.320
232380868656NoneV3 Item No 2.5(ii)AClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer.A In area of light jungle A.In area of light jungle ---- etc., complete with all leadSqm463.74463.7416.5828FalseNoneNoneFalseNoneFalse7690.1076720
232380968656NoneV1 Item No 1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.In all kinds of soil upto 300 mm depth ---- etc., complete with all leadCum112.1112.1505.53FalseNoneNoneFalseNoneFalse56669.9130
232381068656NoneV1 Item No 1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work, In all types of soil upto 3.00 m depth ---- etc., complete with all leadCum120.36120.361107.3914FalseNoneNoneFalseNoneFalse133285.6289040
232381168656NoneV1 Item No 1.15.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work, In ordinary/soft rock without blasting upto 1.5 m depth ---- etc., complete with all leadCum428.34428.34109.5357FalseNoneNoneFalseNoneFalse46918.5217380
232381268656NoneV1 Item No 2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates ---- etc., complete with all leadCum7067.027067.02231.0005FalseNoneNoneFalseNoneFalse1632485.153510
232381368656NoneV2 Item No 4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. ---- etc., complete with all leadSqm139.24139.24573.6467FalseNoneNoneFalseNoneFalse79874.5665080
232381468656NoneV1 Item No 2.2.3Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Footing Concrete ---- etc., complete with all leadCum8074.68074.6115.803FalseNoneNoneFalseNoneFalse935062.90380
232381568656NoneV1 Item No 2.5.2Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Column Pedestal ---- etc., complete with all leadCum8224.138224.1336.7074FalseNoneNoneFalseNoneFalse301886.4295620
232381668656NoneV1 Item No 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Columns ---- etc., complete with all leadCum13727.0613727.0640.5979FalseNoneNoneFalseNoneFalse557289.8091740
232381768656NoneV1 Item No 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Plinth Beam, Roof Slab and Stair Case ---- etc., complete with all leadCum12112.1112112.11148.6694FalseNoneNoneFalseNoneFalse1800700.1264340
232381868656NoneV1 Item No 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Lintel and Roof Beam ---- etc., complete with all leadCum12919.5812919.5847.2879FalseNoneNoneFalseNoneFalse610939.8070820
232381968656NoneV1 Item No 1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete with all leadCum313.88313.88313.4398FalseNoneNoneFalseNoneFalse98382.4844240
232382068656NoneV1 Item No 1.8Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. ---- etc., complete with all leadCum559.32559.321569.4FalseNoneNoneFalseNoneFalse877796.8080
232382168656NoneV1 Item No 2.11 aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification ---- etc., complete with all leadTonne105559.26105559.2641.8117FalseNoneNoneFalseNoneFalse4413612.1113420
232382268656NoneV1 Item No 2.1.4Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all leadCum10637.2910637.2949.9776FalseNoneNoneFalseNoneFalse531626.2247040
232382368656NoneV2 Item No 6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete with all leadSqm1545.81545.81526.0915FalseNoneNoneFalseNoneFalse2359032.24070
232382468656NoneV2 Item No 6.34Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete with all leadSqm1302.721302.72225.726FalseNoneNoneFalseNoneFalse294057.774720
232382568656NoneV2 Item No 12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- etc., complete with all leadCum116601.7116601.72.2537FalseNoneNoneFalseNoneFalse262785.251290
232382668656NoneV2 Item No 12.93.1Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Size 62 x 100mm ---- etc., complete with all leadMtr828.36828.3669.55FalseNoneNoneFalseNoneFalse57612.4380
232382768656NoneV2 Item No 12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- etc., complete with all leadNos1198.881198.8843.0FalseNoneNoneFalseNoneFalse51551.840
232382868656NoneV2 Item No 11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- etc., complete with all leadKg198.24198.242491.02FalseNoneNoneFalseNoneFalse493819.80480
232382968656NoneV2 Item No 11.5.1Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete with all leadSqm5284.045284.0417.7FalseNoneNoneFalseNoneFalse93527.5080
232383068656NoneV2 Item No 12.57.5Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. ---- etc., complete with all leadNos4551.264551.2686.13FalseNoneNoneFalseNoneFalse392000.02380
232383168656NoneV2 Item No 12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer ofK value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) 30 mm thickness ---- etc., complete with all leadNos4112.34112.320.475FalseNoneNoneFalseNoneFalse84199.34250
232383268656NoneV2 Item No 12.74.1Providing and fixing IS : 12817 marked stainless steel butt hinges withstainless steel screws etc. complete :125x64x1.90mm ---- etc., complete with all leadNos120.36120.36164.0FalseNoneNoneFalseNoneFalse19739.040
232383368656NoneV2 Item No 12.76.2Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :200x10mm ---- etc., complete with all leadNos413.0413.0164.0FalseNoneNoneFalseNoneFalse67732.00
232383468656NoneV2 Item No 12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete ---- etc., complete with all leadNos279.66279.6682.0FalseNoneNoneFalseNoneFalse22932.120
232383568656NoneV2 Item No 12.58Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. ---- etc., complete with all leadNos141.6141.682.0FalseNoneNoneFalseNoneFalse11611.20
232383668656NoneV2 Item No 12.9Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all leadSqm7946.127946.12103.5FalseNoneNoneFalseNoneFalse822423.420
232383768656NoneV2 Item No 12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size - 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all leadSqm6748.426748.429.72FalseNoneNoneFalseNoneFalse65594.64240
232383868656NoneV2 Item No 8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm248.98248.98655.0116FalseNoneNoneFalseNoneFalse163084.7881680
232383968656NoneV2 Item No 8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge... ( Inside) ---- etc., complete with all leadSqm368.16368.161125.2591FalseNoneNoneFalseNoneFalse414275.3902560
232384068656NoneV2 Item No 8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm346.92346.921479.9727FalseNoneNoneFalseNoneFalse513432.1290840
232384168656NoneV2 Item No 8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete with all leadSqm118.0118.01762.2707FalseNoneNoneFalseNoneFalse207947.94260
232384268656NoneV2 Item No 8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. ---- etc., complete with all leadMtr61.3661.36308.0FalseNoneNoneFalseNoneFalse18898.880
232384368656NoneV2 Item No 9.17.2Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm ---- etc., complete with all leadSqm1386.51386.5390.4175FalseNoneNoneFalseNoneFalse541313.863750
232384468656NoneV2 Item No 9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. ---- etc., complete with all leadSqm1049.021049.0229.8346FalseNoneNoneFalseNoneFalse31297.0920920
232384568656NoneV2 Item No 9.20.2Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 600x600 mm ---- etc., complete with all leadSqm246.62246.62390.4175FalseNoneNoneFalseNoneFalse96284.763850
232384668656NoneV2 Item No 9.2Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per direction of Engineer incharge. ---- etc., complete with all leadSqm944.0944.0108.0FalseNoneNoneFalseNoneFalse101952.00
232384768656NoneV2 Item No 8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm149.86149.861762.2707FalseNoneNoneFalseNoneFalse264093.8871020
232384868656NoneV2 Item No 8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm184.08184.082090.6431FalseNoneNoneFalseNoneFalse384845.5818480
232384968656NoneV2 Item No 8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm59.059.0248.8999FalseNoneNoneFalseNoneFalse14685.09410
232385068656NoneV2 Item No 8.43Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade :Two coats on new work including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm110.92110.92113.2FalseNoneNoneFalseNoneFalse12556.1440
232385168656NoneV2 Item No 8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm62.5462.5420.07FalseNoneNoneFalseNoneFalse1255.17780
232385268656NoneV2 Item No 8.4Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm135.7135.7176.8299FalseNoneNoneFalseNoneFalse23995.817430
232385368656NoneV2 Item No 11.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete with all leadKg666.7666.727.0499FalseNoneNoneFalseNoneFalse18034.168330
232385468656NoneV2 Item No 9.23Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : ** Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. ---- etc., complete with all leadSqm2909.882909.88212.5007FalseNoneNoneFalseNoneFalse618351.5369160
232385568656NoneV2 Item No 15.1Providing and Applying PU based Elastomeric Liquid Applied PU Waterproofing Membrane single component, cold applied, water based acrylic PU dispersion with highly elastic and UV resistant water proofing treatment to the Existing Roof surface/Chajjas/Sunken portion of WC:Bathroom applied @ 1.2L/per m2,having tensile strength greater than 1.5N/mm2, elongation greater than 300% with solid content not less than 60% in 2 coats including surface preparation, priming the surface with water based acrylic primer @0.1 L/m2, and spreading 60 gsm geotextile between two top coats completely as per specification. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. Polyurethane based Single Component for New Surface ---- etc., complete with all leadSqm964.06964.06621.126FalseNoneNoneFalseNoneFalse598802.731560
232385668656NoneV2 Item No 9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete with all leadSqm1709.821709.82494.8496FalseNoneNoneFalseNoneFalse846103.7430720
232385768656NoneV1 Item No 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Columns ---- etc., complete with all leadCum13807.8113807.811.64FalseNoneNoneFalseNoneFalse22644.80840
232385868656NoneV1 Item No 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Lintel Beam and Roof Beam ---- etc., complete with all leadCum11752.1611752.163.9499FalseNoneNoneFalseNoneFalse46419.8567840
232385968656NoneV1 Item No 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Chajja ---- etc., complete with all leadCum10657.2410657.240.12FalseNoneNoneFalseNoneFalse1278.86880
232386068656NoneV1 Item No 2.11 aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification ---- etc., complete with all leadTonne106614.85106614.850.5866FalseNoneNoneFalseNoneFalse62540.271010
232386168656NoneV2 Item No 6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete with all leadSqm1561.261561.267.73FalseNoneNoneFalseNoneFalse12068.53980
232386268656NoneV2 Item No 8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm251.47251.4717.29FalseNoneNoneFalseNoneFalse4347.91630
232386368656NoneV2 Item No 8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge... ( Inside) ---- etc., complete with all leadSqm371.84371.8461.39FalseNoneNoneFalseNoneFalse22827.25760
232386468656NoneV2 Item No 8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete with all leadSqm119.18119.1878.68FalseNoneNoneFalseNoneFalse9377.08240
232386568656NoneV2 Item No 8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. ( Outside) ---- etc., complete with all leadSqm350.39350.3980.2FalseNoneNoneFalseNoneFalse28101.2780
232386668656NoneV2 Item No 8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. ---- etc., complete with all leadm61.9761.9730.45FalseNoneNoneFalseNoneFalse1886.98650
232386768656NoneV2 Item No 8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm151.36151.3678.68FalseNoneNoneFalseNoneFalse11909.00480
232386868656NoneV2 Item No 8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm185.92185.9280.2FalseNoneNoneFalseNoneFalse14910.7840
232386968656NoneV2 Item No 8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm63.1763.171.89FalseNoneNoneFalseNoneFalse119.39130
232387068656NoneV2 Item No 8.4Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm137.06137.061.89FalseNoneNoneFalseNoneFalse259.04340
232387168656NoneV2 Item No 15.1Providing and Applying PU based Elastomeric Liquid Applied PU Waterproofing Membrane single component, cold applied, water based acrylic PU dispersion with highly elastic and UV resistant water proofing treatment to the Existing Roof surface/Chajjas/Sunken portion of WC:Bathroom applied @ 1.2L/per m2,having tensile strength greater than 1.5N/mm2, elongation greater than 300% with solid content not less than 60% in 2 coats including surface preparation, priming the surface with water based acrylic primer @0.1 L/m2, and spreading 60 gsm geotextile between two top coats completely as per specification. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. ---- etc., complete with all leadSqm973.7973.783.14FalseNoneNoneFalseNoneFalse80953.4180
232387268656NoneV1 Item No 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all leadCum13000.7713000.770.48FalseNoneNoneFalseNoneFalse6240.36960
232387368656NoneV2 Item No 11.16.1Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (P.No.82, I.No. 11.16.1 of PWD SR 2023-24 Vol-2) ---- etc., complete with all leadKg160.48160.48976.956FalseNoneNoneFalseNoneFalse156781.898880
232387468656NoneV2 Item No 7.38Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal,complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. :(P.No.26, I.No. 7.38 of PWD SR 2023-24 Vol-2) ---- etc., complete with all leadSqm670.24670.2418.816FalseNoneNoneFalseNoneFalse12611.235840
232387568656NoneV-1 Item No 2.2.3Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all leadCum7700.777700.778.648FalseNoneNoneFalseNoneFalse66596.258960
232387668656NoneV-1 Item No 2.2.3Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates forTOP SLAB ---- etc., complete with all leadCum8971.788971.7810.59FalseNoneNoneFalseNoneFalse95011.15020
232387768656NoneV-2 Item No 15.1Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/ Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. ---- etc., complete with all leadSqm964.06964.06206.6FalseNoneNoneFalseNoneFalse199174.7960
232387868656NoneV-2 Item No 8.3.1Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm417.72417.72234.4FalseNoneNoneFalseNoneFalse97913.5680
232387968656None18-19 SR Item No XXIV (624)C. I Manhole covers 24" x 24" and with frame 610 * 455mm size (38kgs) ---- etc., complete with all leadNos2500.02500.014.0FalseNoneNoneFalseNoneFalse35000.00
232388068656NoneV-1 Item No 1.14.2Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth 3 to 6m ---- etc., complete with all leadCum138.06138.062.496FalseNoneNoneFalseNoneFalse344.597760
232388168656NoneV-1 Item No 1.15.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work Depth exceeding 1.5 m, but not exceeding 3 m ---- etc., complete with all leadCum533.36533.369.984FalseNoneNoneFalseNoneFalse5325.066240
232388268656NoneV-1 Item No 1.15.3Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work Depth exceeding 1.5 m, but not exceeding 3 m ---- etc., complete with all leadCum546.34546.341.9968FalseNoneNoneFalseNoneFalse1090.9317120
232388368656NoneV-1 Item No 1.16.1Earth work excavation for FOUNDATION by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work In Hard Rock ( requiring blasting) Depth upto 1.50m ---- etc., complete with all leadCum653.72653.722.496FalseNoneNoneFalseNoneFalse1631.685120
232388468656NoneV-1 Item No 1.16.2Earth work excavation for FOUNDATION by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work In Hard Rock ( requiring blasting) Depth exceeding 1.5 m, but not exceeding 3 m ---- etc., complete with all leadCum735.14735.142.496FalseNoneNoneFalseNoneFalse1834.909440
232388568656NoneV-1 Item No 1.16.3Earth work excavation for FOUNDATION by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work In Hard Rock ( requiring blasting) Depth exceeding 1.5 m, but not exceeding 3 m ---- etc., complete with all leadCum838.98838.980.4992FalseNoneNoneFalseNoneFalse418.8188160
232388668656NoneV-3 Item No 1.1 aLoading and Unloading of Stone Boulder/Stone aggregates/Sand/Kankar/Moorum. (Tipper 10 m3) ---- etc., complete with all leadCum159.3159.370.6748FalseNoneNoneFalseNoneFalse11258.495640
232388768656NoneV1 Item No 2.5.2Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Beam ---- etc., complete with all leadCum11214.7211214.721.9872FalseNoneNoneFalseNoneFalse22285.8915840
232388868656NoneV1 Item No 2.5.2Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for lintel-beam ---- etc., complete with all leadCum11962.3711962.370.576FalseNoneNoneFalseNoneFalse6890.325120
232388968656NoneLeast Quotation RateSteel Windows with grill for residential buildings Providing and fixing of windows made of pre-painted steel (base steel as per IS 513 of0.58mm tick galvanized as per IS 277 with zinc of 120 GSM). Primer coated with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with 5-7microns thick alkyd backer. Section for outer frame should be of 48x50mm, centre mullion should be of 48x50mm, section for shutter should be of 48x25mm and fixed glass beading section should be of 12x12mm. Outer frame and mullions to have rebate for glazed shutter and a 20mm provision for guard bars/grills. The sections are to be cut to length mitre joined with corner bracket. Centre mullion is to be fixed with mullion cap. Handle stay 2Nos of stainless steel heavy duty pivot hinges shall be provided for shutter. The window should be panelled with 5mm thick plain fioat glass. Rubber gaskets are to be provided all around the glass. The above frames should be fixed to the concrete/ masonry wall by means of self expanding screws, including 10mm square guard bars with 6" (152.4mm) pitch etc., complete for finished item of work. ---- etc., complete with all leadSqm4434.444434.442.25FalseNoneNoneFalseNoneFalse9977.490
232389068656NoneV-2 Item No 8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. . (outside) ---- etc., complete with all leadSqm437.78437.781187.32FalseNoneNoneFalseNoneFalse519784.94960
232389168656NoneV-5 Item No 12.4Geophysical investigation of site for sinking Borewell for supplying drinking water to Habitation either through the Handpump, MWS or PWSS by vertical sounding by adopting veener sounding by adopting veener or schlumbergers's including reconassiance of survey of Geological formation,geophysical investigation of existing ground water in the vicinity quality, quantity and acceptability of the user including the location of site,recommended department of casing pipe required to seal the top and consolidated formation including an extra depth of 1.00Mtr in consolidated formation including an extra depth of drilling required to cover full depth of occupier proposed to trap probable yield and other information required including transportation of instrument and accessories to work site engaging technical personnel labour required etc complete as directed by Engineer in charge ---- etc., complete with all leadEach6239.846239.841.0FalseNoneNoneFalseNoneFalse6239.840
232389268656NoneV-5 Item No 12.1Sinking of borewell of 165 mm dia clear using super fast hydraulic of capasity 300 PSIG & above 1100 CMF & above in all strata including over burden upto 20 M fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle crew charges and cost of consumables, etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes) for piped water supply schemes Upto 50 Mtrs ---- etc., complete with all leadRmtr436.6436.650.0FalseNoneNoneFalseNoneFalse21830.00
232389368656NoneV-5 Item No 12.1Sinking of borewell of 165 mm dia clear using super fast hydraulic of capasity 300 PSIG & above 1100 CMF & above in all strata including over burden upto 20 M fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle crew charges and cost of consumables, etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes) for piped water supply schemes Above 50 Mtrs and upto 100 Mtr. ---- etc., complete with all leadRmtr547.52547.5250.0FalseNoneNoneFalseNoneFalse27376.00
232389468656NoneV-5 Item No 12.1Sinking of borewell of 165 mm dia clear using super fast hydraulic of capasity 300 PSIG & above 1100 CMF & above in all strata including over burden upto 20 M fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle crew charges and cost of consumables, etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes) for piped water supply schemes Above100 Mtrs. and upto 150 Mtr. ---- etc., complete with all leadRmtr581.74581.7450.0FalseNoneNoneFalseNoneFalse29087.00
232389568656NoneV-5 Item No 12.1Sinking of borewell of 165 mm dia clear using super fast hydraulic of capasity 300 PSIG & above 1100 CMF & above in all strata including over burden upto 20 M fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle crew charges and cost of consumables, etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes) for piped water supply schemes Above150 Mtrs. and upto 200 Mtr. ---- etc., complete with all leadRmtr674.96674.9650.0FalseNoneNoneFalseNoneFalse33748.00
232389668656NoneV-5 Item No 12.1Sinking of borewell of 165 mm dia clear using super fast hydraulic of capasity 300 PSIG & above 1100 CMF & above in all strata including over burden upto 20 M fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle crew charges and cost of consumables, etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes) for piped water supply schemes Above200 Mtrs. and upto 250 Mtr. ---- etc., complete with all leadRmtr791.78791.7850.0FalseNoneNoneFalseNoneFalse39589.00
232389768656NoneV-5 Item No 12.1Sinking of borewell of 165 mm dia clear using super fast hydraulic of capasity 300 PSIG & above 1100 CMF & above in all strata including over burden upto 20 M fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle crew charges and cost of consumables, etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes) for piped water supply schemes Above250 Mtrs. and upto 300 Mtr. ---- etc., complete with all leadRmtr873.2873.235.0FalseNoneNoneFalseNoneFalse30562.00
232389868656NoneV-5 Item No 12.32Supply Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. ---- etc., complete with all leadRmtr2280.942280.9425.0FalseNoneNoneFalseNoneFalse57023.50
232389968656NoneV-5 Item No 13.28Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments ---- etc., complete with all leadRmtr649.0649.0200.0FalseNoneNoneFalseNoneFalse129800.00
232390068656NoneV-5 Item No 12.33Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments ---- etc., complete with all leadNos177.0177.01.0FalseNoneNoneFalseNoneFalse177.00
232390168656NoneV-5 Item No 12.34Providing and laying at site of work MS casing caps as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge ---- etc., complete with all leadNos193.52193.521.0FalseNoneNoneFalseNoneFalse193.520
232390268656NoneLeast Quotation RateProviding NP/CP 50mm dia Waste Unions conforming to ISI specifications and fixing them in position as per directions (Rates includes cost of materials fixtures and conveyance to work spot etc complete) ---- etc., complete with all leadNos247.8247.81.0FalseNoneNoneFalseNoneFalse247.80
232390368656NoneV-5 Item No 13.13.6Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 5.00 HP - 90 LPM @ 110 m = 10 STG Outlet Dia - 2.00" ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete with all leadEach37921.6637921.661.0FalseNoneNoneFalseNoneFalse37921.660
232390468656NoneV-5 Item No 13.23.2Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter Up to 3 to 6 HP ---- etc., complete with all lead& lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete with all leadEach11269.011269.01.0FalseNoneNoneFalseNoneFalse11269.00
232390568656NoneV-5 Item No 13.29Supply and delivery at site 50mm(2”) dia heavy duty CI adopter set complete suitable for uPVC Column pipes for Submersible pumpsets. complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete with all leadSet1829.01829.01.0FalseNoneNoneFalseNoneFalse1829.00
232390668656NoneV-5 Item No 13.31Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets. ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete with all leadJob47.247.2100.0FalseNoneNoneFalseNoneFalse4720.00
232390768656NoneV-5 Item No 13.32Labour charges for Erection, Electrification and commissioning works of Pump sets including aligning and balancing with all necessary erection of materials and labour including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges, tools and equipments etc., involved in the job. as per specifications, with testing of as per instructions of engineer incharge of work ---- etc., complete with all lead& lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete with all leadJob7670.07670.01.0FalseNoneNoneFalseNoneFalse7670.00
232390868656NoneV-5 Item No 13.33Labour charges for Erection of outdoor type panel board and meter board units with all necessary materials and labour tools and equipments including providing cement concrete foundation bed etc., complete. as per specifications, with testing of as per instructions of engineer incharge of work ---- etc., complete with all lead& lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete with all leadJob1593.01593.01.0FalseNoneNoneFalseNoneFalse1593.00
232390968656NoneV-6 Item No 2.6.2Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirmining to table 3 class 5 of IS:8130-1984 and virgin grade PVC insulation and sheathed suitable for working voltage upto 1100Volts as per IS-694:1990 & confirming to GTP of GROUP-A(12/2.10) 3C x 6 mm ---- etc., complete with all leadRmtr198.24198.24259.0FalseNoneNoneFalseNoneFalse51344.160
232391068656NoneV-6 Item No 5.42.2Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG ---- etc., complete with all leadSq CM0.510.5130000.0FalseNoneNoneFalseNoneFalse15300.00
232391168656NoneV-6 Item No 5.44.4Supply and Installation I Fixing I Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase I Three Phase Energy Meter in suitable base plate and having a provision for Fuse I MCB cutout with suitable transparent hinged flap opening for operating MCB along with 10 complete tamper proof SEALING facility. (50/6.42) 600mmx600mmx170mm. ---- etc., complete with all leadEach17133.617133.61.0FalseNoneNoneFalseNoneFalse17133.60
232391268656NoneV-6 Item No 5.6.6Supplying and fixing polished wood board made of not less than 15mm thick plank on both sides with planks made out of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws etc. - 500 x 500 x 65 mm (20" x 20" x 2.5") etc., complete as per directions of the Engineer-in-charge ---- etc., complete with all leadEach384.83384.831.0FalseNoneNoneFalseNoneFalse384.830
232391368656NoneLeast Quotation Rate.Supplying and fixing miniature circuit breakers/Isolators on existing MCB distribution boards using necessary fixing materials and wiring complete as directed by the Engineer-in-charge - 5 to 30 Amps Triple and Neutral ---- etc., complete with all leadEach2023.72023.71.0FalseNoneNoneFalseNoneFalse2023.70
232391468656NoneLeast Quotation Rate.Supplying and fixing TPST with neutral link switches rewirable fuse type - Havels / Standard / Indo-Asian Crescent - 30 to 35 Amps, etc., complete as per directions of the Engineer-in-charge ---- etc., complete with all leadEach2124.02124.01.0FalseNoneNoneFalseNoneFalse2124.00
232391568656NoneLeast Quotation Rate.Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery (48/6.35) ---- etc., complete with all leadEach472.0472.01.0FalseNoneNoneFalseNoneFalse472.00
232391668656NoneV-3 Item No 3.1Removal of Unserviceable Soil with Disposal upto a suitable distance as directed by the Engineer incharge of work ---- etc., complete with all leadCum100.3100.39.0FalseNoneNoneFalseNoneFalse902.70
232391768656NoneV-3 Item No 3.7Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction. ---- etc., complete with all leadCum123.9123.927.0FalseNoneNoneFalseNoneFalse3345.30
232391868656NoneV-3 Item No 4.2 B (V)Construction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401 .For Grading -V Material ---- etc., complete with all leadCum2783.622783.6213.5FalseNoneNoneFalseNoneFalse37578.870
232391968656NoneV-3 Item No 4.17Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in ---- etc., complete with all leadCum3019.623019.6213.5FalseNoneNoneFalseNoneFalse40764.870
232392068656NoneV-3 Item No 8.42.3Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra) 600 x 300 x 150 mm Kerb Stone ---- etc., complete with all leadm546.34546.3430.0FalseNoneNoneFalseNoneFalse16390.20
232392168656NoneV-3 Item No 8.1Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces ---- etc., complete with all leadSqm128.62128.6221.0FalseNoneNoneFalseNoneFalse2701.020
232392268656NoneV-3 Item No 6.6Plain Cement Pavement Quality M30 grade Concrete (RMC) with OPC & GGBS laid without Paver Construction of un-reinforced plain cement concrete pavement using RMC M-30 grade with OPC @ 270 kg/m3 and GGBS@ 90kg/m3 (75:25 proportion) as per approved mix design procedure and thickness as per design, over a prepared sub base. The superplastisiser confirming to IS 9103-1999 Reaffirmed-2008, Coarse aggregates and Fine aggregate confirming to IS:383-2016, transported to site, laid in approved fixed side form work (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the form work). Spreading the concrete with shovels, rackers and compacted using needle, suitable plate vibrator and finished in a continuous operation including provision of separation membrane and Hessian cloth finishing to lines and grades complete including cost of all materials, labour, all lead & lift, loading charges as per specification & direction of Engineer - incharge of the work. (Groove cutting shall be paid seperately ---- etc., complete with all leadCum7993.327993.3213.5FalseNoneNoneFalseNoneFalse107909.820
232392368656NoneV-3 Item No 6.8.1Providing and laying 60mm thick factory made precast M -30 grade Cement Concrete Paver Block as per IRC SP 63:2018 & IS 15658 for Cycle Tracks & Pedestrian Footpaths of approved shape and colour, laid in required pattern and including over 30mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-incharge. (WMM/WBM Base to be paid separately if necessary as per relevant technical specification) ---- etc., complete with all leadSqm1260.241260.2460.0FalseNoneNoneFalseNoneFalse75614.40
232392468656NoneV-1 Item No 2.1.4Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all leadCum7336.067336.066.0FalseNoneNoneFalseNoneFalse44016.360
232392568656NoneV-1 Item No 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for COLUMNS ---- etc., complete with all leadCum8029.438029.439.45FalseNoneNoneFalseNoneFalse75878.11350
232392668656NoneV-1 Item No 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Footing ---- etc., complete with all leadCum7518.467518.465.4FalseNoneNoneFalseNoneFalse40599.6840
232392768656NoneV-1 Item No 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Plinth Beam ---- etc., complete with all leadCum8759.388759.3818.0FalseNoneNoneFalseNoneFalse157668.840
232392868656NoneV-2 Item No 14.28.2.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40mm dia pipes, From wash basin waste lines ---- etc., complete with all leadm108.56108.5610.0FalseNoneNoneFalseNoneFalse1085.60
232392968656NoneV-5 Item No 16.7.4Providing and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make including trench excavation and refilling etc. for EXTERNAL WORKS with: ---- etc., complete with all leadm164.02164.0250.0FalseNoneNoneFalseNoneFalse8201.00
232393068656NoneV-5 Item No 657PVC pipe - OD 75mm and 6 Kg/sqcm, waste lines, (Shaft Drainage) ---- etc., complete with all leadm145.14145.1485.0FalseNoneNoneFalseNoneFalse12336.90
232393168656NoneV-5 Item No 647PVC pipe - OD 110mm and 6 Kg/sqcm, sanitary lines, (Shaft Drainage) ---- etc., complete with all leadm300.9300.9250.0FalseNoneNoneFalseNoneFalse75225.00
232393268656NoneV-2 Item No 13.47Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 75mm diameter ---- etc., complete with all leadm232.46232.46100.0FalseNoneNoneFalseNoneFalse23246.00
232393368656NoneV-2 Item No 13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter ---- etc., complete with all leadm343.38343.3850.0FalseNoneNoneFalseNoneFalse17169.00
232393468656NoneApproved Rate Providing, fixing, testing and commissioning of deep seal PVC multi inlet floor trap of self cleansing design moulded or fabricated with CP grating, rubber ring / solvent cement followed by application of leak proof adhesive like FRP paste including making good the floors etc., complete as directed by the Engineer in charge & approved quality confirming to ISI or BIS Standards (Market Rate) ---- etc., complete with all leadNos371.7371.720.0FalseNoneNoneFalseNoneFalse7434.00
232393568656NoneSR 2018-19 Item No 37.28.1Drilling holes of 2.50 cms dia (roof/chajja/stone). in slabs upto 7.50 cms thick ---- etc., complete with all leadNos154.58154.5830.0FalseNoneNoneFalseNoneFalse4637.40
232393668656NoneSR 2018-19 Item No 37.28.2Drilling holes of 2.50 cms dia (roof/chajja/stone). in slabs upto 10 cms thick ---- etc., complete with all leadNos185.26185.2630.0FalseNoneNoneFalseNoneFalse5557.80
232393768656NoneV-2 Item No 14.32.2Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm ---- etc., complete with all leadEach1201.241201.245.0FalseNoneNoneFalseNoneFalse6006.20
232393868656NoneV-2 Item No 13.9.2Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter ---- etc., complete with all leadNos329.22329.225.0FalseNoneNoneFalseNoneFalse1646.10
232393968656NoneV-2 Item No 14.22BProviding and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. ---- etc., complete with all leadNos6563.166563.164.0FalseNoneNoneFalseNoneFalse26252.640
232394068656NoneV-2 Item No 14.40.2600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. ---- etc., complete with all leadNos585.28585.286.0FalseNoneNoneFalseNoneFalse3511.680
232394168656NoneV-2 Item No 14.3.1Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous chinaflushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mmflush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete,including painting of fittings and brackets, cutting and making goodthe walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid ---- etc., complete with all leadNos7052.867052.863.0FalseNoneNoneFalseNoneFalse21158.580
232394268656NoneV-2 Item No 14.4.1Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: ---- etc., complete with all leadNos5763.125763.123.0FalseNoneNoneFalseNoneFalse17289.360
232394368656NoneApproved Rate Supplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ). (Market Rate) ---- etc., complete with all leadNos2183.02183.03.0FalseNoneNoneFalseNoneFalse6549.00
232394468656NoneV-2 Item No 14.1.1Providing & fixing White vitreous china water closet squatting pan (Indian type) along with "S" or "P" trap including dismantling of old WC seat and "S" or "P" trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge. Orissa pattern W.C Pan of size 580x440 mm ---- etc., complete with all leadEach5763.125763.123.0FalseNoneNoneFalseNoneFalse17289.360
232394568656NoneV-2 Item No 14.4.3Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : Range of three urinal basins with 10litre white P.V.C. automatic flushing cistern ---- etc., complete with all leadNos11156.911156.94.0FalseNoneNoneFalseNoneFalse44627.60
232394668656NoneV-2 Item No 14.11.2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm ---- etc., complete with all leadNos5996.765996.764.0FalseNoneNoneFalseNoneFalse23987.040
232394768656NoneApproved Rate Supplying, fixing, testing and commissioning of Sink Cock with Swinging Casted Spout (Wall Mounted Model): CON-CHR-347KN for pantry sink with CP wall flange etc. Standard make confirming to ISI standards,Model as per attached photo catalogue and as per instruction of engineer incharge. ( Jaguar make or Equalent ) (Market Place) ---- etc., complete with all leadNos1146.961146.961.0FalseNoneNoneFalseNoneFalse1146.960
232394868656NoneApprove Rate Providing and fixing in position Exposed Part Kit of Concealed Stop Cock with Fitting Sleeve, Operating Lever & Adjustable Wall Flange (Compatible with ALD-087FT) ( Jaguar make or Equalent ) including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. (Market Place) ---- etc., complete with all leadNos1024.911024.912.0FalseNoneNoneFalseNoneFalse2049.820
232394968656NoneV-2 Item No 14.7.1Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps ---- etc., complete with all leadNos3636.763636.768.0FalseNoneNoneFalseNoneFalse29094.080
232395068656NoneApproved Rate Supplying and fixing PCC Pedestal 450 x 250 x 200mm with MS sloted angle iron brackets, supports with necessary drilling holes to suit the insertion of pipe clamps deburning etc., as per detailed drawing for supporting water supply pipes with suitable MS clamps, bolts, anchor bolts, nuts and washers fixed on shaft walls / outer walls etc. The quoted rate shall include with the cost of brackets galvanizing with zinc alloy of 0.08mm thick conformed to IS 1239 etc., complete as directed by the employer. (Market Rate) ---- etc., complete with all leadNos767.0767.030.0FalseNoneNoneFalseNoneFalse23010.00
232395168656NoneV-2 Item No 13.32.1Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal dia Pipes ---- etc., complete with all leadm195.88195.88200.0FalseNoneNoneFalseNoneFalse39176.00
232395268656NoneV-2 Item No 13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia Pipes ---- etc., complete with all leadm447.22447.22250.0FalseNoneNoneFalseNoneFalse111805.00
232395368656NoneV-2 Item No 13.33.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 20 mm nominal dia Pipes ---- etc., complete with all leadm256.06256.06200.0FalseNoneNoneFalseNoneFalse51212.00
232395468656NoneV-2 Item No 13.33.5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 40 mm nominal dia Pipes ---- etc., complete with all leadm562.86562.86200.0FalseNoneNoneFalseNoneFalse112572.00
232395568656NoneApproved Rate Supplying, installing, testing and commissioning of approved make full way lever operated forged brass ball valve of brass body with forged brass hard chromeplated steel ball tested to a pressure not less than 20 Kg / sqcm with threaded joints complete. a) 20mm dia (Market Rate) ---- etc., complete with all leadNos649.0649.04.0FalseNoneNoneFalseNoneFalse2596.00
232395668656NoneApproved Rate Supplying, installing, testing and commissioning of approved make full way lever operated forged brass ball valve of brass body with forged brass hard chromeplated steel ball tested to a pressure not less than 20 Kg / sqcm with threaded joints complete.b) 25mm dia (Market Rate) ---- etc., complete with all leadNos944.0944.02.0FalseNoneNoneFalseNoneFalse1888.00
232395768656NoneV-2 Item No 14.55 aProviding and fixing Bib cock with wall flange made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class economy ---- etc., complete with all leadEach1318.061318.062.0FalseNoneNoneFalseNoneFalse2636.120
232395868656NoneV-2 Item No 13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank. ---- etc., complete with all leadLtr10.6210.625000.0FalseNoneNoneFalseNoneFalse53100.00
232395968656NoneV-5 Item No 16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover ---- etc., complete with all leadLtr6435.726435.7220.0FalseNoneNoneFalseNoneFalse128714.40
232396068656NoneApproved Rate O.T. S.S. Surgical Scrub Station - 2 Bay ; Floor mounted Size:- 2100 x 600 x 1000 + 300 mm LxWxH + Flashback Technical Specifications S.S. 304 Grade ; 16 SWG Floor mounted with slopy radius chamber 2 Electric ON- OFF Foot operated Switches for washing 1 manual Foot operated Valve connected to one Switch 2 manual wire rod Holders for liquid detergent container Flashback at 300 mm Height Nylon adjustable levelling bullets for legs Note: Plumbing and other accessories not in our scope ---- etc., complete with all leadLtr206500.0206500.01.0FalseNoneNoneFalseNoneFalse206500.00
232396168656None1.2.1Supplying heavy gauge PVC Conduit pipe…dia.. Mm thick confirming to IS 2509 with suitable size bends, metal/pvc junction boxes,adesive paste etc.., and running before concreting the slab .the conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using pvc end enclosures, run with 185WG GI fish wire wherever necessary. (P.No. 1/.I.No.1.2)PWD Electrical SR 22-23 19/20 mm dia 2mm thick ---- etc., complete with all leadm77.8877.8830.0FalseNoneNoneFalseNoneFalse2336.40
232396268656None1.2.2Supplying heavy gauge PVC Conduit pipe…dia.. Mm thick confirming to IS 2509 with suitable size bends, metal/pvc junction boxes,adesive paste etc.., and running before concreting the slab .the conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using pvc end enclosures, run with 185WG GI fish wire wherever necessary. (P.No. 1/.I.No.1.2)PWD Electrical SR 22-23 25mm dia 2mm thick ---- etc., complete with all leadm92.0492.04450.0FalseNoneNoneFalseNoneFalse41418.00
232396368656None1.3.1Supplying heavy gauge pvc conduit pipe…dia.. Mm thick confirming to IS 2509 with suitable size bends ,metal junction boxes, adhesive paste etc by groove cutting in the wall and fixing by bracing Uor Jhooks and cement plastering upto the wall surface and run with 18SWG GI fish wire run thoughout the conduit wherever neccessary (P.No. 1/.I.No.1.3)PWD Electrical SR 22-23 19/20 mm dia 2mm thick ---- etc., complete with all leadm82.6582.6520.0FalseNoneNoneFalseNoneFalse1653.00
232396468656None1.3.2Supplying heavy gauge pvc conduit pipe…dia.. Mm thick confirming to IS 2509 with suitable size bends ,metal junction boxes, adhesive paste etc by groove cutting in the wall and fixing by bracing Uor Jhooks and cement plastering upto the wall surface and run with 18SWG GI fish wire run thoughout the conduit wherever neccessary (P.No. 1/.I.No.1.3)PWD Electrical SR 22-23 25mm dia 2mm thick ---- etc., complete with all leadm96.0296.02300.0FalseNoneNoneFalseNoneFalse28806.00
232396568656None1.5.1Supplying and fixing PVC/metal conduit Deep junction box (P.No. 1/.I.No.1.5)PWD Electrical SR 22-23 19/20 mm deep junction box ---- etc., complete with all leadEach57.8257.828.0FalseNoneNoneFalseNoneFalse462.560
232396668656None1.5.2Supplying and fixing PVC/metal conduit Deep junction box (P.No. 1/.I.No.1.5)PWD Electrical SR 22-23 25 mm deep junction box ---- etc., complete with all leadEach66.0866.0825.0FalseNoneNoneFalseNoneFalse1652.00
232396768656None1.11Supplying And Fixing Metal Fan Box with Round Hook. (P.No.2/.I.No.1.11) PWD Electrical SR 22-23 ---- etc., complete with all leadNos142.2142.225.0FalseNoneNoneFalseNoneFalse3555.00
232396868656None2.2.1Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.(P.No.3/.I.No.2.2) PWD Electrical SR 22-23 short point upto 3mtr from tapping point to out let via switch box ---- etc., complete with all leadPoint317.42317.4230.0FalseNoneNoneFalseNoneFalse9522.60
232396968656None2.2.2Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.(P.No.3/.I.No.2.2) PWD Electrical SR 22-23 Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch box ---- etc., complete with all leadPoint447.22447.2240.0FalseNoneNoneFalseNoneFalse17888.80
232397068656None2.2.3Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.(P.No.3/.I.No.2.2) PWD Electrical SR 22-23 Long point above 6Mtr upto 10Mtr from tapping point to out let via switch box ---- etc., complete with all leadPoint654.9654.975.0FalseNoneNoneFalseNoneFalse49117.50
232397168656None2.2.4Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.(P.No.3/.I.No.2.2) PWD Electrical SR 22-23 Two outlet in a row, above 3Mtr upto 6Mtr from tapping point to out let via switches. ---- etc., complete with all leadPoint798.86798.865.0FalseNoneNoneFalseNoneFalse3994.30
232397268656None2.3.2Wiring for lighting / power circuit using one of FRLS PVC insulated1100V grade multi strand copper with low conductor resistance single core wire in open or consealed system of wiring.as per IS-694:1990 & confirming to latest amendments (P. No.3/ I.No.2.3) PWD Electrical SR 22-23 1.5 sqmrn ---- etc., complete with all leadMtr30.6830.68750.0FalseNoneNoneFalseNoneFalse23010.00
232397368656None2.3.3Wiring for lighting / power circuit using one of FRLS PVC insulated1100V grade multi strand copper with low conductor resistance single core wire in open or consealed system of wiring.as per IS-694:1990 & confirming to latest amendments (P. No.3/ I.No.2.3) PWD Electrical SR 22-23 2.5 sqmrn ---- etc., complete with all leadMtr49.5649.561200.0FalseNoneNoneFalseNoneFalse59472.00
232397468656None2.3.4Wiring for lighting / power circuit using one of FRLS PVC insulated1100V grade multi strand copper with low conductor resistance single core wire in open or consealed system of wiring.as per IS-694:1990 & confirming to latest amendments (P. No.3/ I.No.2.3) PWD Electrical SR 22-23 4.0 sqmrn ---- etc., complete with all leadMtr74.3474.34400.0FalseNoneNoneFalseNoneFalse29736.00
232397568656None2.6.2Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirmining to table 3 class 5 of IS:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100Volts as per IS:694-1990 (P.No.4/.I.No.2.6) PWD Electrical SR 22-23 3C X 4.0Sq.mm ---- etc., complete with all leadMtr198.24198.24100.0FalseNoneNoneFalseNoneFalse19824.00
232397668656None3.4.1Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall (P. No.5/ I.No.3.4)PWD Electrical SR 22-23 1-2Way ---- etc., complete with all leadEach162.84162.8410.0FalseNoneNoneFalseNoneFalse1628.40
232397768656None3.4.2Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall (P. No.5/ I.No.3.4)PWD Electrical SR 22-23 3 Way ---- etc., complete with all leadEach187.62187.628.0FalseNoneNoneFalseNoneFalse1500.960
232397868656None3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall (P. No.5/ I.No.3.4)PWD Electrical SR 22-23 4-5Way ---- etc., complete with all leadEach208.86208.866.0FalseNoneNoneFalseNoneFalse1253.160
232397968656None3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall (P. No.5/ I.No.3.4)PWD Electrical SR 22-23 6Way ---- etc., complete with all leadEach259.6259.610.0FalseNoneNoneFalseNoneFalse2596.00
232398068656None3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall (P. No.5/ I.No.3.4)PWD Electrical SR 22-23 8 Way ---- etc., complete with all leadEach307.98307.9818.0FalseNoneNoneFalseNoneFalse5543.640
232398168656None3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall (P. No.5/ I.No.3.4)PWD Electrical SR 22-23 10-12Way ---- etc., complete with all leadEach376.42376.422.0FalseNoneNoneFalseNoneFalse752.840
232398268656None3.5.1Supplying and fixing superior quality modular switch mounting polycorbonate plate with neceaary supporting back plate with rquired nos. of machine screwes, bolts nuts etc., complete on the existing metal/PVC box. (P. No.5/ I.No.3.5)PWD Electrical SR 22-23 1 to 2 Module ---- etc., complete with all leadEach161.66161.6610.0FalseNoneNoneFalseNoneFalse1616.60
232398368656None3.5.2Supplying and fixing superior quality modular switch mounting polycorbonate plate with neceaary supporting back plate with rquired nos. of machine screwes, bolts nuts etc., complete on the existing metal/PVC box. (P. No.5/ I.No.3.5)PWD Electrical SR 22-23 3 Module ---- etc., complete with all leadEach189.98189.988.0FalseNoneNoneFalseNoneFalse1519.840
232398468656None3.5.3Supplying and fixing superior quality modular switch mounting polycorbonate plate with neceaary supporting back plate with rquired nos. of machine screwes, bolts nuts etc., complete on the existing metal/PVC box. (P. No.5/ I.No.3.5)PWD Electrical SR 22-23 4 Module ---- etc., complete with all leadEach206.5206.56.0FalseNoneNoneFalseNoneFalse1239.00
232398568656None3.5.4Supplying and fixing superior quality modular switch mounting polycorbonate plate with neceaary supporting back plate with rquired nos. of machine screwes, bolts nuts etc., complete on the existing metal/PVC box. (P. No.5/ I.No.3.5)PWD Electrical SR 22-23 6 Module ---- etc., complete with all leadEach276.12276.1210.0FalseNoneNoneFalseNoneFalse2761.20
232398668656None3.5.4Supplying and fixing superior quality modular switch mounting polycorbonate plate with neceaary supporting back plate with rquired nos. of machine screwes, bolts nuts etc., complete on the existing metal/PVC box. (P. No.5/ I.No.3.5)PWD Electrical SR 22-23 8 Module ---- etc., complete with all leadEach335.12335.1218.0FalseNoneNoneFalseNoneFalse6032.160
232398768656None3.5.5Supplying and fixing superior quality modular switch mounting polycorbonate plate with neceaary supporting back plate with rquired nos. of machine screwes, bolts nuts etc., complete on the existing metal/PVC box. (P. No.5/ I.No.3.5)PWD Electrical SR 22-23 10-12 Module ---- etc., complete with all leadEach405.92405.922.0FalseNoneNoneFalseNoneFalse811.840
232398868656None3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per 3854 and IS 1293. (P. No.5/ I.No.3.6)PWD Electrical SR 22-23 6Amps one way. ---- etc., complete with all leadEach120.36120.36275.0FalseNoneNoneFalseNoneFalse33099.00
232398968656None3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per 3854 and IS 1293. (P. No.5/ I.No.3.6)PWD Electrical SR 22-23 6Amps two way.switch ---- etc., complete with all leadEach195.88195.882.0FalseNoneNoneFalseNoneFalse391.760
232399068656None3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per 3854 and IS 1293. (P. No.5/ I.No.3.6)PWD Electrical SR 22-23 6Amps 3way socket. ---- etc., complete with all leadEach201.78201.7875.0FalseNoneNoneFalseNoneFalse15133.50
232399168656None3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per 3854 and IS 1293. (P. No.5/ I.No.3.6)PWD Electrical SR 22-23 Stepped Fan Regulator. ---- etc., complete with all leadEach421.26421.2620.0FalseNoneNoneFalseNoneFalse8425.20
232399268656None3.6.8Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per 3854 and IS 1293. (P. No.5/ I.No.3.6)PWD Electrical SR 22-23 16Amps one way switch ---- etc., complete with all leadEach212.4212.46.0FalseNoneNoneFalseNoneFalse1274.40
232399368656None3.6.9Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per 3854 and IS 1293. (P. No.5/ I.No.3.6)PWD Electrical SR 22-23 6Amps Bell push ---- etc., complete with all leadEach208.86208.861.0FalseNoneNoneFalseNoneFalse208.860
232399468656None3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per 3854 and IS 1293. (P. No.5/ I.No.3.6)PWD Electrical SR 22-23 32Amps DP switch ---- etc., complete with all leadEach384.68384.6810.0FalseNoneNoneFalseNoneFalse3846.80
232399568656None3.6.11Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per 3854 and IS 1293. (P. No.5/ I.No.3.6)PWD Electrical SR 22-23 6/16Amps universal socket ---- etc., complete with all leadEach278.48278.4810.0FalseNoneNoneFalseNoneFalse2784.80
232399668656None3.14.5Supplying and fixing/replacing of 6/16/32Amps electrical accessories on existing switch board. (P. No.6/ I.No.3.14) PWD Electrical SR 22-23 6Amps Bakelite ceiling rose ---- etc., complete with all leadNos92.0492.0410.0FalseNoneNoneFalseNoneFalse920.40
232399768656None3.14.6Supplying and fixing/replacing of 6/16/32Amps electrical accessories on existing switch board. (P. No.6/ I.No.3.14) PWD Electrical SR 22-23 6 Amps pendant holder ---- etc., complete with all leadNos83.7883.7840.0FalseNoneNoneFalseNoneFalse3351.20
232399868656None3.8Supplying 4mm thick plastic sheet with necessary nitches for fixing switches regulators etc., and fixing on existing wooden or metal box using N.F. screws.(P. No.6/ I.No.3.8) PWD Electrical SR 22-23 ---- etc., complete with all leadSq CM0.480.481000.0FalseNoneNoneFalseNoneFalse480.00
232399968656None3.10.1supplying 4mm thick white plastic plate and covering for junction boxes or size ... mm conduit using necessary machine screws. (P. No.6/ I.No.3.10) PWD Electrical SR 22-23 80/90mm ---- etc., complete with all leadEach17.717.710.0FalseNoneNoneFalseNoneFalse177.00
232400068656None3.10.2supplying 4mm thick white plastic plate and covering for junction boxes or size ... mm conduit using necessary machine screws. (P. No.6/ I.No.3.10) PWD Electrical SR 22-23 110mm ---- etc., complete with all leadEach24.7824.7810.0FalseNoneNoneFalseNoneFalse247.80
232400168656None5.11.3Supplying of on load change over switches 4 poles,AC-23 Aduty 415V, 50Hz, AC Supply.open execution (P.No.11/.I.No.5.11) PWD Electrical SR 22-23 125 Amps ---- etc., complete with all leadEach12184.6812184.681.0FalseNoneNoneFalseNoneFalse12184.680
232400268656None5.15.1Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. (P.No.12/.I.No.5.14)PWD Electrical SR 22-23 FOUR POLE 100Amps25kA. ---- etc., complete with all leadEach7181.487181.481.0FalseNoneNoneFalseNoneFalse7181.480
232400368656None5.14Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. (P.No.12/.I.No.5.14)PWD Electrical SR 22-23 FOUR POLE 125Amps25kA. ---- etc., complete with all leadEach10145.6410145.643.0FalseNoneNoneFalseNoneFalse30436.920
232400468656None5.15Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. (P.No.12/.I.No.5.14)PWD Electrical SR 22-23 FOUR POLE Supplying and fixing of Shunt trip suitable for MCCB.CBCT. (P.No.12/.I.No.5.15)PWD Electrical SR 22-23 ---- etc., complete with all leadEach2009.542009.541.0FalseNoneNoneFalseNoneFalse2009.540
232400568656None5.18.4Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C type curve indicator on/off energy cross 3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.(P.No.13/.I.No.5.17)PWD Electrical SR 22-23 6-32Amps DP ---- etc., complete with all leadEach872.02872.026.0FalseNoneNoneFalseNoneFalse5232.120
232400668656None5.18.6Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C type curve indicator on/off energy cross 3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.(P.No.13/.I.No.5.17)PWD Electrical SR 22-23 50-63Amps DP ---- etc., complete with all leadEach1300.361300.366.0FalseNoneNoneFalseNoneFalse7802.160
232400768656None5.18.7Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C type curve indicator on/off energy cross 3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.(P.No.13/.I.No.5.17)PWD Electrical SR 22-23 6-32Amps TPN ---- etc., complete with all leadEach2026.062026.068.0FalseNoneNoneFalseNoneFalse16208.480
232400868656None5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C type curve indicator on/off energy cross 3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.(P.No.13/.I.No.5.17)PWD Electrical SR 22-23 50-63Amps TPN ---- etc., complete with all leadEach3643.843643.846.0FalseNoneNoneFalseNoneFalse21863.040
232400968656None5.19.9Supplying and fixing regular MCB distribution boards on wall / woodboard/flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting etc., made out of 14 SWG MS enclosures. .(P.No.13/.I.No.5.18)PWD Electrical SR 22-23 II Double Door 12WaySP&N ---- etc., complete with all leadEach2748.222748.222.0FalseNoneNoneFalseNoneFalse5496.440
232401068656None5.19.12Supplying and fixing regular MCB distribution boards on wall / woodboard/flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting etc., made out of 14 SWG MS enclosures. .(P.No.13/.I.No.5.18)PWD Electrical SR 22-23 III - Double Door 6WayTP &N ---- etc., complete with all leadEach5829.25829.22.0FalseNoneNoneFalseNoneFalse11658.40
232401168656None5.21Supplying,fixingandwiringearthleakagerelaywithcorebalancedcurrenttransformersuitableforsinglephase50HzACwithlatestmicrocontrollerbased,digitalreadoutofpercentageleakagecurrent,programmabledelay/auto/manualresetfacilitysuitabletomountonDIN rail/ flush mounting on panel board. ---- etc., complete with all leadEach10920.910920.91.0FalseNoneNoneFalseNoneFalse10920.90
232401268656None5.31Supplying and fixing Electronic Trivector Meter (ETV) suitable for operation LT operation and -CT operated meter in polycarbonate body in class 0.5 accuracy as per IS 14697 and completely wired..(P.No.14/.I.No.5.31) PWD Electrical SR 22-23 ---- etc., complete with all leadEach5180.25180.21.0FalseNoneNoneFalseNoneFalse5180.20
232401368656None5.33Supplying of multi function digital Meter three line back light LCD type display of voltage, Current, frequency.Power, power factor, KVA, KWH.KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required.with communication port and class 0.5s accuracy.(P.No.14/.I.No.5.33) PWD Electrical SR 22-23 ---- etc., complete with all leadEach10991.710991.71.0FalseNoneNoneFalseNoneFalse10991.70
232401468656None5.34Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accurecy with tape wound . (P.No.14/.I.No.5.34) PWD Electrical SR 22-23 ---- etc., complete with all leadEach663.16663.163.0FalseNoneNoneFalseNoneFalse1989.480
232401568656None5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C. (P.No.14/.I.No.5.38) PWD Electrical SR 22-23 ---- etc., complete with all leadEach607.7607.79.0FalseNoneNoneFalseNoneFalse5469.30
232401668656None5.40.2Supplying.........amps rated 3phase with neutral bus bar using requiemed capacity electrolyticaluminium strips covered with heat shrinkable couloured PVC sleeve, mounted on phenolic/FRP/DMC insulator whcih are mounted on powder coated 40x6mm M.S.tlat frame work in existing panel board.The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary botls,nuts and washers etc., complete. (P.No.15/.I.No.5.40) PWD Electrical SR 22-23 250Arnps 4x30x10mm Alluminium Strips ---- etc., complete with all leadRmtr4053.34053.34.0FalseNoneNoneFalseNoneFalse16213.20
232401768656None5.41.2Supplying and fixing angle iron frame work fabricated out of M.S. angle iron., and M.S. flat... with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.(P.No.15/.I.No.5.41) PWD Electrical SR 22-23 50x50x6mm ---- etc., complete with all leadRmtr466.1466.115.0FalseNoneNoneFalseNoneFalse6991.50
232401868656None5.42.1Fabricating supplying and mounting MS box made out ... SWG suitable for floor/wall mounting, fully weatherproof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete. ((P.No.15/.I.No.5.42) PWD Electrical SR 22-23 14SWG ---- etc., complete with all leadSq CM0.590.59135000.0FalseNoneNoneFalseNoneFalse79650.00
232401968656None6.2.1Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete..(P.No.22/.I.No.6.2) PWD Electrical SR 22-23 12" Sweep (300mm) ---- etc., complete with all leadEach3503.423503.424.0FalseNoneNoneFalseNoneFalse14013.680
232402068656None6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system.(.(P.No.16/.I.No.5.47) PWD Electrical SR 22-23 48" Sweep (1200mm) Regular model ---- etc., complete with all leadEach3521.123521.1222.0FalseNoneNoneFalseNoneFalse77464.640
232402168656None6.5.1Supplying wall mounting fan suitable to operate at single- phase 230v AC. supply..(P.No.23/.I.No.6.5) PWD Electrical SR 22-23 300mm Sweep ---- etc., complete with all leadEach2940.562940.562.0FalseNoneNoneFalseNoneFalse5881.120
232402268656None8.1Supplying and drawing UTP-CAT 6E LAN cable.(P.No.27/.I.No.8.1) PWD Electrical SR 22-23 ---- etc., complete with all leadTonne44.8444.84110.0FalseNoneNoneFalseNoneFalse4932.40
232402368656None8.4.1Supplying & Fixing of switch mounting rack with power manager & Cable manager..(P.No.28/.I.No.8.4) PWD Electrical SR 22-23 4U with 450mm depth ---- etc., complete with all leadEach5772.565772.561.0FalseNoneNoneFalseNoneFalse5772.560
232402468656None8.9.7Supplying fixing of Network Switches 8 port 10/100 Switch ---- etc., complete with all leadEach1239.01239.01.0FalseNoneNoneFalseNoneFalse1239.00
232402568656None8.10.1Supplying & fixing of I/O socket with back box.(P.No.28/.I.No.8.10) PWD Electrical SR 22-23 Single I/O ---- etc., complete with all leadEach578.2578.25.0FalseNoneNoneFalseNoneFalse2891.00
232402668656None11.3.2supplying of ...feet PVC batten integrated LED tube ... Wattts with high quality diffuser with life of 25000 burning hours & 70% lumen maintenance with CRI more than 80 power input 220v-240v @ 50HZ & power factor more than .9 along with CE apporved. 2 years warranty aganist any manufacturing defect working under electrical condition (P. No.34/ I.No.11.3) PWD Electrical SR 2022 -23 LED light fitting 1X4' 20/22 watts ---- etc., complete with all leadEach814.2814.230.0FalseNoneNoneFalseNoneFalse24426.00
232402768656None11.6.2Supplying of recess mounting non integral type ........ LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRI more than 70%. efficacy more than 100 lumen per watt, 120degree beam spread, life more than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF more than 0.95, power loss should less than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition..(P.No.34/.I.No.11.6) PWD Electrical SR 22-23 LED modular down light 1 'x1' 34 -22watts ---- etc., complete with all leadNos4356.564356.564.0FalseNoneNoneFalseNoneFalse17426.240
232402868656None11.6.5Supplying of recess mounting non integral type ........ LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRI more than 70%. efficacy more than 100 lumen per watt, 120degree beam spread, life more than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF more than 0.95, power loss should less than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition..(P.No.34/.I.No.11.6) PWD Electrical SR 22-23 LED modular down light 2'x2' /1' X 4' 34 -36watt ---- etc., complete with all leadNos6959.646959.644.0FalseNoneNoneFalseNoneFalse27838.560
232402968656None11.8. 4Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT more than 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire more than IK08. Power Factor more than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency more than 1301m/w, nominal CRI more than 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source..(P.No.36/.I.No.11.8) PWD Electrical SR 22-23 LED Streetlight 90 Watts ---- etc., complete with all leadNos10454.810454.85.0FalseNoneNoneFalseNoneFalse52274.00
232403068656None11.11.6Supplying & fixing of retrofit type - LED bulb ...... W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI more than 70%. efficacy more than 80 lumen per watt, life more than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF more than 0.95, power loss should less than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition..(P.No.38/.I.No.11.11) PWD Electrical SR 22-23 15W, 6500K ---- etc., complete with all leadEach384.68384.6810.0FalseNoneNoneFalseNoneFalse3846.80
232403168656None12.2.2Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote.(P.No.39/.I.No.12.2) PWD Electrical SR 22-23 Musical ---- etc., complete with all leadEach512.12512.121.0FalseNoneNoneFalseNoneFalse512.120
232403268656None13.7Fixing all types and all capacities fluorescent/false ceiling/spot light/ CFL/LED fittings indoor on the wall /ceiling/rafters/girders using 23/ 0.0076" twin twisted PVC insulated wires, required nos of round blocks and clamps (P.No.45/.I.No.13.7)) On wall/ceiling/Rafter/Girders PWD Electrical SR 2022 ---- etc., complete with all leadEach143.96143.9638.0FalseNoneNoneFalseNoneFalse5470.480
232403368656None13.11Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.(P.No.46/.I.No.13.10) PWD ellectrical SR 2022 - 23 ---- etc., complete with all leadEach371.7371.724.0FalseNoneNoneFalseNoneFalse8920.80
232403468656None13.13Fixing one exhaust fan after making a suitable notch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 A, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.. (P.No.46/.I.No.13.13) PWD Electrical SR 2022 - 23 ---- etc., complete with all leadEach834.26834.264.0FalseNoneNoneFalseNoneFalse3337.040
232403568656None13.1.2Supplying and Fixing........mm dia class A GI pipe bracket upto 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/tubular pole, using suitable clA, bolts, nuts and wiring using suitable capacity wires.(P.No.45/.I.No.13.1) PWD Electrical SR 2022 - 23 Using 32mm dia G.I.Pipe ---- etc., complete with all leadEach1233.11233.15.0FalseNoneNoneFalseNoneFalse6165.50
232403668656None13.18Fixing of ..... A TPST / change over switch / Contactor along with neutral link with screws, bolts, nuts and wiring using required capacity wires and circuit labelling.(P.No.46/.I.No.13.18) PWD Electrical SR 2022 - 23 100A to 250A TPDT/COS ---- etc., complete with all leadEach527.46527.461.0FalseNoneNoneFalseNoneFalse527.460
232403768656None1.01RCC Pole - 9 Mtr Long, 145 Kg WL (Dwg No. BESCOM/GM/QS&S/02 Dtd 24.11.2018) as per IS-785 (P.No.01/.I.No.1) BESCOM SR 2021 - 22 PART III ---- etc., complete with all leadNos8349.688349.685.0FalseNoneNoneFalseNoneFalse41748.40
232403868656None2.0411 kV, Special 3 Pin Cross Arm - GI (P.No.01/.I.No.14) BESCOM SR 2021 - 22 PART III ---- etc., complete with all leadNos1358.181358.184.0FalseNoneNoneFalseNoneFalse5432.720
232403968656None2.06LT 4 Pin Cross Arm - GI (P.No.01/.I.No.16) BESCOM SR 2021 - 22 PART III ---- etc., complete with all leadNos447.22447.222.0FalseNoneNoneFalseNoneFalse894.440
232404068656None5.04RCC Pole Clamp - GI (P.No.02/.I.No.32) BESCOM SR 2021 - 22 PART III ---- etc., complete with all leadNos112.1112.15.0FalseNoneNoneFalseNoneFalse560.50
232404168656None5.1Guy Clamp - GI (P.No.01/.I.No.40) BESCOM SR 2021 - 22 PART III ---- etc., complete with all leadNos135.7135.72.0FalseNoneNoneFalseNoneFalse271.40
232404268656None5.13Anchor Rod using 12 mm rounds/Guy Rod - GI (P.No.02/.I.No.43) BESCOM SR 2021 - 22 PART III ---- etc., complete with all leadNos388.22388.222.0FalseNoneNoneFalseNoneFalse776.440
232404368656None5.15GI Fish Plate (P.No.02/.I.No.45) BESCOM SR 2021 - 22 PART III ---- etc., complete with all leadNos105.02105.022.0FalseNoneNoneFalseNoneFalse210.040
232404468656None6.0611 kV, 5 kN Composite/Polymeric Pin Insulator (24 mm dia FRP Rod) (P.No.02/.I.No .51) BESCOM SR 2021 - 22 PART III ---- etc., complete with all leadNos241.9241.99.0FalseNoneNoneFalseNoneFalse2177.10
232404568656None6.078 Strain Insulator (P.No.02/.I.No .52) BESCOM SR 2021 - 22 PART III ---- etc., complete with all leadNos31.8631.868.0FalseNoneNoneFalseNoneFalse254.880
232404668656None6.09DISC Insulator 45 kN Porcelain (P.No.02/.I.No .54) BESCOM SR 2021 - 22 PART III ---- etc., complete with all leadNos601.8601.86.0FalseNoneNoneFalseNoneFalse3610.80
232404768656None7.02Rabbit ACSR (6/3.35 mm Al + 1/3.35 mm St), Std Wt: 214 Kg/KM (P.No.03/.I.No .61) BESCOM SR 2021 - 22 PART III ---- etc., complete with all leadKm54556.1254556.120.4FalseNoneNoneFalseNoneFalse21822.4480
232404868656None8.017/10 SWG Guy Wire (7/3.251 mm Dia), Std Wt: 680 Kg/KM (P.No.03/.I.No .64) BESCOM SR 2021 - 22 PART III ---- etc., complete with all leadTonne91126.6891126.680.025FalseNoneNoneFalseNoneFalse2278.1670
232404968656None8.028 SWG GI Wire (4.064 mm Dia), Std Wt: 125 Kg/KM ---- etc., complete with all leadTonne88547.288547.20.03FalseNoneNoneFalseNoneFalse2656.4160
232405068656None12.04Distribution Transformer - 3 Phase, 11kV/433V - Stacked CRGO Core with Oil as per IS-1180 (Part-1): 2014 63 kVA, Aluminum Wdg, Star 2 (5 Star) (P.No.04/.I.No .105) BESCOM SR 2021 - 22 PART III ---- etc., complete with all leadNos215403.1215403.11.0FalseNoneNoneFalseNoneFalse215403.10
232405168656None17.01LT Protection Kit (Dwg No. BESCOM/GM/QS&S/10 Dtd 24.11.2018) (P.No.05/.I.No .151) BESCOM SR 2021 - 22 PART III ---- etc., complete with all leadNos2387.142387.141.0FalseNoneNoneFalseNoneFalse2387.140
232405268656None18.02LT Distribution Box for 100 kVA DTC with MCCB's (Sheet Metal) (Dwg No. BESCOM/GM/QS&S/58 Dtd 24.11.2018 (P.No.06/.I.No .152) BESCOM SR 2021 - 22 PART III ---- etc., complete with all leadNos26920.5226920.521.0FalseNoneNoneFalseNoneFalse26920.520
232405368656None19.019 kV, 5 kA Lightning Arrester Metal Oxide Ceramic type with GROUND DISCONNECTOR (Dwg No. BESCOM/GM/QS&S/26 Dtd 24.10.2007) (P.No.06/.I.No .152) BESCOM SR 2021 - 22 PART III ---- etc., complete with all leadSet1085.61085.61.0FalseNoneNoneFalseNoneFalse1085.60
232405468656None20.0111 kV, HG Fuse Unit with Solid Core Insulator (Dwg No. BESCOM/GM/QS&S/21 Dtd 24.11.2018) (P.No.06/.I.No .157) BESCOM SR 2021 - 22 PART III ---- etc., complete with all leadSet1261.421261.421.0FalseNoneNoneFalseNoneFalse1261.420
232405568656None21.01Double Pole TC Set for erection of Transformer on RCC/PSCC 9 Mtr Long Poles as per IS-1977 For 25/63/100 kVA 4/5 Star Rated Transformer on RCC Pole - 9 Mtr Long, 145 Kg WL - MS (P.No.06/.I.No .160) BESCOM SR 2021 - 22 PART III ---- etc., complete with all leadSet20725.5220725.521.0FalseNoneNoneFalseNoneFalse20725.520
232405668656None24.0111 kV, 200 Amps Single Break GOS (Dwg No. BESCOM/GM/QS&S/23 Dtd 24.11.2018) (P.No.08/.I.No .184) BESCOM SR 2021 - 22 PART III ---- etc., complete with all leadSet11151.011151.01.0FalseNoneNoneFalseNoneFalse11151.00
232405768656None24.07H - Frame Set for fixing 11 kV, 200 Amps Single Break GOS - (For DP structure for providing New GOS for sectionalisation) - GI (P.No.08/.I.No .188) BESCOM SR 2021 - 22 PART III ---- etc., complete with all leadSet7163.787163.781.0FalseNoneNoneFalseNoneFalse7163.780
232405868656None24.1Insulated GOS Operating Rods (P.No.08/.I.No .191) BESCOM SR 2021 - 22 PART III ---- etc., complete with all leadNos487.34487.341.0FalseNoneNoneFalseNoneFalse487.340
232405968656None25.0211 kV, DOLO Cutout REC Specification (Dwg No. BESCOM/GM/QS&S/20 Dtd 24.11.2018) (P.No.08/.I.No .193) BESCOM SR 2021 - 22 PART III ---- etc., complete with all leadSet5004.385004.381.0FalseNoneNoneFalseNoneFalse5004.380
232406068656None194DP Set (2 Pole Strucrure Kit) as per IS-1977 For RCC Pole - 9 Mtr Long, 145KG WL/PSCC Pole - 9 Mtr Long, 300Kg WL - MS (Dwg No. BESCOM/GM/QS&S/35 & 63 Dtd 24.11.2018) (P.No.08/.I.No .194) BESCOM SR 2021 - 22 PART III ---- etc., complete with all leadSet7553.187553.181.0FalseNoneNoneFalseNoneFalse7553.180
232406168656None32.051.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 (P.No.09/.I.No .32) BESCOM SR 2021 - 22 PART III 16 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm) (P.No.09/.I.No .215) BESCOM SR 2021 - 22 PART III ---- etc., complete with all leadKm167373.56167373.560.12FalseNoneNoneFalseNoneFalse20084.82720
232406268656None32.071.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 (P.No.09/.I.No .32) BESCOM SR 2021 - 22 PART III 35 Sqmm, 3.5 Core, (14 GI Strips - 4 x 0.8 mm) (P.No.09/.I.No .219) BESCOM SR 2021 - 22 PART III ---- etc., complete with all leadKm212215.92212215.920.2FalseNoneNoneFalseNoneFalse42443.1840
232406368656None52.01Transparent Alkathine tube 19 mm dia, 2 mm thick in coils of 30 Mtr (P.No.17/.I.No .444) BESCOM SR 2021 - 22 PART III ---- etc., complete with all leadCoil610.06610.061.0FalseNoneNoneFalseNoneFalse610.060
232406468656None53.04LT 3 Phase, 4 Wire, CT Operated DLMS Complaint ETV Meter-5A, class 0.5s Accuracy (Used for 25 HP/18KW & Above Installations, DTC Metering (P.No.18/.I.No .451) BESCOM SR 2021 - 22 PART III ---- etc., complete with all leadNos2808.42808.41.0FalseNoneNoneFalseNoneFalse2808.40
232406568656None5.37Supplying .fixing and wiring heavy duty low voltage capacitors conforming to IS 2834, 3 phase, 400/440 volts grade, for power factor improvement of rotating machinerieslike induction motor.(P.No14/.I.No.5.37) ---- etc., complete with all leadKvar566.4566.45.0FalseNoneNoneFalseNoneFalse2832.00
232406668656None21.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff (P.No.09/ .I.No.31.06/) BESCOM SR 20211-22 PART IV 2.5 to 25 Sqmm ---- etc., complete with all leadKm24645.4824645.480.12FalseNoneNoneFalseNoneFalse2957.45760
232406768656None21.06Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff (P.No.09/ .I.No.31.06/) BESCOM SR 20211-22 PART IV 35 sqmm to 95 sqmm ---- etc., complete with all leadKm27903.4627903.460.2FalseNoneNoneFalseNoneFalse5580.6920
232406868656None74aSupplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes ( (P.No.43/ .I.No.6.17)PWD ELECTRICAL SR 2019-20 1.5 sqmm ---- etc., complete with all leadEach3.543.5432.0FalseNoneNoneFalseNoneFalse113.280
232406968656None74bSupplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes ( (P.No.43/ .I.No.6.17)PWD ELECTRICAL SR 2019-20 6 sqmm ---- etc., complete with all leadEach8.268.2640.0FalseNoneNoneFalseNoneFalse330.40
232407068656None74cSupplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes ( (P.No.43/ .I.No.6.17)PWD ELECTRICAL SR 2019-20 35 sqmm long barrel ---- etc., complete with all leadEach37.7637.7632.0FalseNoneNoneFalseNoneFalse1208.320
232407168656None11.2.5 V-5Providing, Laying and Fixing GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing). (P.No.142/ .I.No.1/2.5) WS&UGD works SR 2022 For Medium Duty GI pipe: 40mm dia ---- etc., complete with all leadRmtr575.84575.8412.0FalseNoneNoneFalseNoneFalse6910.080
232407268656None13.39 V-5Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia. (P.No.164/.I.No. P430A) WS&UGD works SR 2022 ---- etc., complete with all leadJob4425.04425.012.0FalseNoneNoneFalseNoneFalse53100.00
232407368656None12.58.1Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required.(P.No.40/.I.No.6.3) PWD Electrical SR 2019-20 25x3mm Gl strip ---- etc., complete with all leadMtr96.7696.7630.0FalseNoneNoneFalseNoneFalse2902.80
232407468656None12.58.11Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required.(P.No.40/.I.No.6.3) PWD Electrical SR 2019-20 600x600x3mm Copper plate ---- etc., complete with all leadEach8756.788756.781.0FalseNoneNoneFalseNoneFalse8756.780
232407568656None1.1.2Digging of Pit 1.8 Mtr depth for errection of 9 to 10 Mtr Long Steel/RCC/PSCC supports as per approved Drawing. (P.No.01/.I.No .1.1) BESCOM SR 2021 - 22 PART IV Hard Soil ---- etc., complete with all leadPer Pit1335.761335.765.0FalseNoneNoneFalseNoneFalse6678.80
232407668656None1.7.2Digging of Pit for GUY SET. (P.No.01/.I.No .1.7) BESCOM SR 2021 - 22 PART IV Hard Soil ---- etc., complete with all leadPer Pit742.22742.222.0FalseNoneNoneFalseNoneFalse1484.440
232407768656None1.8aProviding cement concrete to Poles and Guy sets with material and labour including necessary curing etc., complete (cost doesnot include excavation) (P.No.01/.I.No .1.8) BESCOM SR 2021 - 22 PART IV Base Concreting with CC 1:4: 8 Pole base for 11/9.5/9/8 Mtr supports (500x650x150mm) ---- etc., complete with all leadEach322.14322.145.0FalseNoneNoneFalseNoneFalse1610.70
232407868656None1.8bPole Concreting with CC 1:2:4 (without coping) 9 Mtr support (650x500x1700mm) ---- etc., complete with all leadEach3726.443726.445.0FalseNoneNoneFalseNoneFalse18632.20
232407968656None2.02Erection of RCC/PSCC Pole of 9 to 10 Mtr long in a pit of 1.8 Mtr depth(P.No.02/.I.No .2.02) BESCOM SR 2021 - 22 PART IV ---- etc., complete with all leadEach1313.341313.345.0FalseNoneNoneFalseNoneFalse6566.70
232408068656None3.01Erection of Double Pole Transformer Structure using 9 Mtr Long RCC (145 Kg WL)/PSCC (300 Kg WL) Pole including fixing of Structure Materials, Erection of Poles etc., complete for mounting of Transformer as per approved drawing For 25/63/100 kVA (P.No.02/.I.No .3.01) BESCOM SR 2021 - 22 PART IV ---- etc., complete with all leadPer Structure6755.56755.51.0FalseNoneNoneFalseNoneFalse6755.50
232408168656None2.09Erection of H-Frame. (P.No.02/.I.No .2.09) BESCOM SR 2021 - 22 PART IV ---- etc., complete with all leadEach381.14381.141.0FalseNoneNoneFalseNoneFalse381.140
232408268656None5.02Fixing of 4 Pin cross arm with Insulator and Braces fixing(P.No.02/.I.No .5.02) BESCOM SR 2021 - 22 PART IV ---- etc., complete with all leadEach188.8188.82.0FalseNoneNoneFalseNoneFalse377.60
232408368656None5.03Fixing of V-Shape/Horizontal cross arm including Single Top Support Brace and Insulator fixing (P.No.02/.I.No .5.03) BESCOM SR 2021 - 22 PART IV ---- etc., complete with all leadEach188.8188.85.0FalseNoneNoneFalseNoneFalse944.00
232408468656None5.10Fixing of GUY Set with break insulator making use of 7/3.15 mm (7/10 SWG) galvanised steel wire with turn buckle and anchoring arrangement as per approved drawing. (Excluding excavation of PIT)(P.No.02/.I.No .5.10) BESCOM SR 2021 - 22 PART IV ---- etc., complete with all leadEach313.88313.882.0FalseNoneNoneFalseNoneFalse627.760
232408568656None6.02Stringing of conductor Rabbit ACSR, binding of conductor on each insulator and dead ending on strain or disc/strain insulator by means of clamps.(P.No.03/.I.No .5.70) BESCOM SR 2021 - 22 PART IV ---- etc., complete with all leadPer Km3752.43752.40.4FalseNoneNoneFalseNoneFalse1500.960
232408668656None8.01Erection of 25 to 63 kVA Transformer on Transformer Structure .(P.No.03/.I.No .7.01) BESCOM SR 2021 - 22 PART IV ---- etc., complete with all leadEach1407.741407.741.0FalseNoneNoneFalseNoneFalse1407.740
232408768656None11.01Fixing Metering Box for housing the ETV Meter 3 Phase 4 Wire along with CT's, Meter & wiring for DTC 25/63 kVA TC (P.No.04/.I.No .11.01) BESCOM SR 2021 - 22 PART IV ---- etc., complete with all leadSet2296.282296.281.0FalseNoneNoneFalseNoneFalse2296.280
232408868656None13.01Fixing DOLO Cutout/Horn Gap Fuse including fixing of cross arm and wiring(P.No.05/.I.No .13.01) BESCOM SR 2021 - 22 PART IV ---- etc., complete with all leadEach279.66279.663.0FalseNoneNoneFalseNoneFalse838.980
232408968656None13.02Fixing of GOS including wiring (11 kV Single Break 200 Amps) (P.No.05/.I.No .13.02) BESCOM SR 2021 - 22 PART IV ---- etc., complete with all leadEach1302.721302.721.0FalseNoneNoneFalseNoneFalse1302.720
232409068656None13.06Fixing of 3 Nos Lightning Arrestor including wiring (P.No.05/.I.No .13.07) BESCOM SR 2021 - 22 PART IV ---- etc., complete with all leadSet106.2106.21.0FalseNoneNoneFalseNoneFalse106.20
232409168656None15.04Wiring of 1 Circuit of LT Wiring for for 25/63/100 kVA DTC to the existing LT protection Kit/Distribution Box via metering box. (includes fixing of necessary supports like 2 Pin cross arm, Spacer etc) (P.No.06/.I.No .15.04) BESCOM SR 2021 - 22 PART IV ---- etc., complete with all leadSet848.42848.421.0FalseNoneNoneFalseNoneFalse848.420
232409268656None29.01Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr, Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed. (P.No.08/.I.No .29.03) BESCOM SR 2021 - 22 PART IV in Hard soil ---- etc., complete with all leadCum459.02459.0225.0FalseNoneNoneFalseNoneFalse11475.50
232409368656None29.07Refilling the cable trenches with selected available earth from trench excavation including watering, consolidation in layers of 15 cm. Thickness including depositing of the surplus earth with a lead of 200 Mtr (P.No.08/.I.No .29.07) BESCOM SR 2021 - 22 PART IV in Hard soil ---- etc., complete with all leadCum68.4468.4425.0FalseNoneNoneFalseNoneFalse1711.00
232409468656None10.1Supplying, installing, testing and commissioning of Diesel Generator set with following specifications. Power rating as per standard reference condition as per-BS 5514/ISO 3046/ ISO 8528 & IS 1002/ISO 3046 Generator set specifications. Engine: Diesel generating set are rated at 1500RPM and conform to ISO 8528 specifications. The engines are radiator cooled, four stroke and multi cylinder, conforming to ISO 3046. The scope of supply includes: Electrical starter motor12V DC Battery charging alternator, Bosch fuel system with mechanical governor, A1 Class. Spin-on lube oil filter, Spin-on dual fuel filter with water separator, Turbocharger, Charge air cooler, Silencer (Hospital grade), Dry type air cleaner, Shutoff coil, Flywheel and flywheel housing, First fill of lube oil and coolant, Safety for low lube oil pressure, Safety for high water temperature, Permissible overload of 10% for one hour in 12 hours of operation Capacity of Fuel Tank: Fuel tank suitable for 8 hours of operation Alternator: Alternator is suitable for operation at 1500 RPM, 415 Volts, 0.8 pf (lag) suitable for 50 Hz, 3 phase, 4 wire systems, conforming to IS/IEC 60034-1. The Alternator is brush less type, screen protected, revolving field, self excited, self regulated through an AVR. The alternator shall have plus or minus 1.0% Voltage regulation (max) in static conditions- IP: 23 protections with insulation class F&H. Mounting arrangement: Engine and alternator are mounted on a common MS fabricated base frame with AVM pads. Control Panel: The control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish. The control panel consists of the following parts:- PS0500 Controller, Aluminium bus bars with suitable capacity within/outgoing terminals, Indicating lamps for 'Load On' and 'Set Running', Instrument fuses duly wired and ferruled, MCCB of suitable rating with overload and short circuit protections. Genset Controller: microprocessor based generator set monitoring and control system. The control provides a simple operator interface to the generator set, manual and remote start/ stop control, shutdown fault indication, and an LCD hour counter. The integration of all functions into a single control system provides enhanced reliability and performance compared to conventional generator set control systems. This control has been designed and tested to meet harsh environment in which gensets are typically applied. Features, Functions, protections 16 character x 2 line alphanumeric LCD display with LED Backlight Operator interface, Provide a record of most recent fault conditions. Fault history stored in the control non volatile memory, Provide Alternator Data. Voltage (1 ph or 3 ph line to line and line to neutral voltage, Current (1 ph or 3 ph), kVA (3 ph and total), Frequency, Provide Engine Data, Starting battery voltage, Engine running hours, Engine Temp, Engine oil pressure, Control includes provision for Service adjustment and calibration of DG control functions, Voltage, frequency selection, Configurable input and output set up, Meter calibration, Engine controls, Power Start operates on 12 VDC batteries,-Auto start mode accepts a ground signal from remote devices to automatically start the DG set The remote start will also wake up the control system from sleep mode. Engine Starting -The control system supports automatic engine starting, Primary and back up start disconnects are achieved by battery charging alternator feedback or main alternator output frequency. Controller provide configurable time delay of 0-300 sees to start after remote start signal and time delay of 0-600secs prior to shut down after stop signal. Sleep mode increase battery life. : etc., : 25 KVA/20kw ---- etc., complete with all leadSet532299.18532299.181.0FalseNoneNoneFalseNoneFalse532299.180
232409568656None7.4.3Supplying, installation, testing and commissioning of solar hot water heater comprising of high quality Evacuated Glass Tube (EGT) with absorber coating collector of size 58 x 1800 mm. Inner tank Material-Stainless steel 304-L Grade with Aluminium Stucco cladding made of High quality PUF insulation to minimizes heat loss and hold water Temperature upto 72 Hrs...with appropriate capacity electrical back up arrangement excluding inlet and out let pipes. Fitted with Sacrificial Anode (P.No.27/.I.No.7.4) PWD Electrical SR 22-23 300 Liter capacity- 29 nos Tubes ---- etc., complete with all leadEach60803.0460803.041.0FalseNoneNoneFalseNoneFalse60803.040
232409668656None9.2.5Supplying,erecting,testing&commissioningofOFF-LINEUPSsystemsuitableforoperationon230V,50Hz,A/Csupply,withallaccessories complete and Excluding batteries and wiring complete. 5 kVA OFF LINE UPS ---- etc., complete with all leadEach47079.6447079.641.0FalseNoneNoneFalseNoneFalse47079.640
232409768656None6.7.2Supplying......TRsplitAirconditionerssuitableforoperationonA/Csupplysinglephase50Hz230Vwithhermeticallysealedcompressorwithaircooledcondenser,motorcapacitorandstartruncapacitors,relayandoverloadprotectorinternalunit,withoneindoorandoneoutdoorunitThecondenserunitwillbeplacedoutsidetheroomontheterracetoavoidnoiseincludingstandardlengthofsuitablesizecoppertubingcoveredwithinsulationtube.(Highwallchorded/cordless)suitablecapacity3coresheathed/PVCcoppercable and a battery operated wireless remote unit 1.5 Ton capacity ---- etc., complete with all leadEach56265.9456265.942.0FalseNoneNoneFalseNoneFalse112531.880
17065135970001NoneNoneBuildings3 Upgradation of infrastructure facilities to the General Hospital and Staff quarters at Gudibande General Hospital in Chikkaballpura District13419912.28
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
232409868657NoneV2 Item No 19.55Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground to the appropriate disposal area as per direction of Engineer-in-charge. ---- etc., complete with all leadSqm44.9744.97262.3FalseNoneNoneFalseNoneFalse11795.6310
232409968657NoneV2 Item No 20.89Repairs to plaster in patches of 2.5 m2 and less in walls, ceilings 10 to 20mm thick in cement mortar 1:4 including cutting the patches in proper shape and replastering the surface of the wall including disposal of rubbish with a lead of 50m including curing cost of materials, labour, complete as per specification ---- etc., complete with all leadSqm460.64460.64112.5FalseNoneNoneFalseNoneFalse51822.00
232410068657NoneV1 Item No 2.4.1Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all leadCum7783.427783.4268.4893FalseNoneNoneFalseNoneFalse533080.9874060
232410168657NoneV2 Item No 8.53.2Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 g/L, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. ---- etc., complete with all leadSqm120.32120.32496.0503FalseNoneNoneFalseNoneFalse59684.7720960
232410268657NoneV2 Item No 8.64Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :One coats on old work as per specifications and as per directions of Engineer in charge. ---- etc., complete with all leadSqm92.3792.3749.005FalseNoneNoneFalseNoneFalse4526.591850
232410368657NoneV2 Item No 8.75.1Finishing walls with Premium Acrylic Smooth exterior paint of required shade : Old work (Two coats applied @ 1.43 l/ 10 m²) over existing cement paint surface including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm134.91134.91228.4975FalseNoneNoneFalseNoneFalse30826.5977250
232410468657NoneV1 Item No 2.1.3Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates ---- etc., complete with all leadCum7279.037279.0389.08FalseNoneNoneFalseNoneFalse648415.99240
232410568657NoneV-2 Item No 8.3.1Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm430.25430.25488.04FalseNoneNoneFalseNoneFalse209979.210
232410668657NoneV2 Item No 15.2Polyurethane based Single Component for Existing Surface Providing and Applying PU based Elastomeric Liquid Applied PU Waterproofing Membrane single component, cold applied, water based acrylic PU dispersion with highly elastic and UV resistant water proofing treatment to the Existing Roof surface/Chajjas/Sunken portion of WC: Bathroom applied @ 1.2 l/per m2, having tensile strength greater than 1.5N/mm2, elongation greater than 300% with solid content not less than 60% in 2 coats including surface preparation, priming the surface with water based acrylic primer @0.1 l/m2, and spreading 60 gsm geotextile between two top coats completely as per specification. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. ---- etc., complete with all leadSqm895.75895.75123.5068FalseNoneNoneFalseNoneFalse110631.21610
232410768657NoneV2 Item No 20.103Repairing door and window frames with available wood to the required size. ---- etc., complete with all leadSqm1185.021185.0210.5FalseNoneNoneFalseNoneFalse12442.710
232410868657NoneV2 Item No 20.104Repairing and fixing shutters (panelled or glazed) to doors, windows, ventilators and cupboards. ---- etc., complete with all leadSqm1185.021185.0210.5FalseNoneNoneFalseNoneFalse12442.710
232410968657NoneV2 Item No 20.107Providing and fixing plain rolled glass 4mm thick with teakwood beading of 10mm thick. ---- etc., complete with all leadSqm1394.061394.061.7FalseNoneNoneFalseNoneFalse2369.9020
232411068657NoneV2 Item No 12.58Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. ---- etc., complete with all leadNos145.85145.8525.0FalseNoneNoneFalseNoneFalse3646.250
232411168657NoneV2 Item No 12.55.1Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. -do- with both side prelam ---- etc., complete with all leadSqm2875.642875.647.5FalseNoneNoneFalseNoneFalse21567.30
232411268657NoneV2 Item No 13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter ---- etc., complete with all leadm353.68353.68158.0FalseNoneNoneFalseNoneFalse55881.440
232411368657NoneV2 Item No 9.17.2Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm ---- etc., complete with all leadm1428.11428.1488.5673FalseNoneNoneFalseNoneFalse697722.961130
232411468657NoneV2 Item No 9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. ---- etc., complete with all leadm1080.491080.49128.05FalseNoneNoneFalseNoneFalse138356.74450
232411568657NoneV2 Item No 9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete with all leadm1761.111761.11486.35FalseNoneNoneFalseNoneFalse856515.84850
232411668657NoneV2 Item No 8.2.1Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadm358.54358.54486.347FalseNoneNoneFalseNoneFalse174374.853380
232411768657NoneV3 Item No 2.5(ii)AClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer.A In area of light jungle A.In area of light jungle ---- etc., complete with all leadSqm477.65477.655.71FalseNoneNoneFalseNoneFalse2727.38150
232411868657NoneV1 Item No 1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.In all kinds of soil upto 300 mm depth ---- etc., complete with all leadCum115.46115.46171.29FalseNoneNoneFalseNoneFalse19777.14340
232411968657NoneV1 Item No 1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work, In all types of soil upto 3.00 m depth ---- etc., complete with all leadCum123.97123.97264.06FalseNoneNoneFalseNoneFalse32735.51820
232412068657NoneV1 Item No 1.15.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work, In ordinary/soft rock without blasting upto 1.5 m depth ---- etc., complete with all leadCum441.19441.1943.58FalseNoneNoneFalseNoneFalse19227.06020
232412168657NoneV-3 Item No 3.1Removal of Unserviceable Soil with Disposal upto a suitable distance as directed by the Engineer incharge of work ---- etc., complete with all leadCum103.31103.3148.0FalseNoneNoneFalseNoneFalse4958.880
232412268657NoneV2 Item No 4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. for Plinth area ---- etc., complete with all leadCum143.42143.42115.0FalseNoneNoneFalseNoneFalse16493.30
232412368657NoneV2 Item No 2.2.2.1Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Column Pedestal ---- etc., complete with all leadCum8252.528252.5215.82FalseNoneNoneFalseNoneFalse130554.86640
232412468657NoneV1 Item No 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For Lintel ---- etc., complete with all leadCum13307.1713307.1713.6025FalseNoneNoneFalseNoneFalse181010.7799250
232412568657NoneV1 Item No 1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete with all leadCum323.3323.3348.961FalseNoneNoneFalseNoneFalse112819.09130
232412668657NoneV1 Item No 1.8Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. ---- etc., complete with all leadCum576.1576.1126.41FalseNoneNoneFalseNoneFalse72824.8010
232412768657NoneV1 Item No 2.11 aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification ---- etc., complete with all leadTonne108726.04108726.048.9792FalseNoneNoneFalseNoneFalse976272.8583680
232412868657NoneV1 Item No 2.1.4Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all leadCum10956.4110956.416.5FalseNoneNoneFalseNoneFalse71216.6650
232412968657NoneV2 Item No 6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete with all leadSqm1592.171592.17580.56FalseNoneNoneFalseNoneFalse924350.21520
232413068657NoneV2 Item No 6.34Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete with all leadSqm1341.81341.828.365FalseNoneNoneFalseNoneFalse38060.1570
232413168657NoneV2 Item No 11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- etc., complete with all leadKg204.19204.19545.58FalseNoneNoneFalseNoneFalse111401.98020
232413268657NoneV2 Item No 11.5.1Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete with all leadSqm5442.565442.566.3FalseNoneNoneFalseNoneFalse34288.1280
232413368657NoneV2 Item No 8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge... ( Inside) ---- etc., complete with all leadSqm379.2379.2400.19FalseNoneNoneFalseNoneFalse151752.0480
232413468657NoneV2 Item No 8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete with all leadSqm121.54121.54527.69FalseNoneNoneFalseNoneFalse64135.44260
232413568657NoneV-2 Item No 8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. ( Outside) ---- etc., complete with all leadSqm424.17424.17170.32FalseNoneNoneFalseNoneFalse72244.63440
232413668657NoneV2 Item No 8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm154.36154.36527.39FalseNoneNoneFalseNoneFalse81407.92040
232413768657NoneV2 Item No 8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm189.6189.6740.32FalseNoneNoneFalseNoneFalse140364.6720
232413868657NoneV2 Item No 8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm60.7760.77150.28FalseNoneNoneFalseNoneFalse9132.51560
232413968657NoneV2 Item No 8.43Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade :Two coats on new work including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm114.25114.25119.7FalseNoneNoneFalseNoneFalse13675.7250
232414068657NoneV2 Item No 11.16.1Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (P.No.82, I.No. 11.16.1 of PWD SR 2023-24 Vol-2) ---- etc., complete with all leadKg165.29165.29242.56FalseNoneNoneFalseNoneFalse40092.74240
232414168657NoneV2 Item No 7.38Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal,complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. :(P.No.26, I.No. 7.38 of PWD SR 2023-24 Vol-2) ---- etc., complete with all leadSqm690.35690.3518.816FalseNoneNoneFalseNoneFalse12989.62560
232414268657NoneV-3 Item No 3.7Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction. ---- etc., complete with all leadCum127.62127.6248.0FalseNoneNoneFalseNoneFalse6125.760
232414368657NoneV-3 Item No 4.2 B (V)Construction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401 .For Grading -V Material ---- etc., complete with all leadCum2867.132867.1324.0FalseNoneNoneFalseNoneFalse68811.120
232414468657NoneV-3 Item No 4.17Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in ---- etc., complete with all leadCum3110.213110.2124.0FalseNoneNoneFalseNoneFalse74645.040
232414568657NoneV-3 Item No 8.42.3Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra) 600 x 300 x 150 mm Kerb Stone ---- etc., complete with all leadm562.73562.7380.0FalseNoneNoneFalseNoneFalse45018.40
232414668657NoneV-3 Item No 8.1Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces ---- etc., complete with all leadSqm132.48132.4856.0FalseNoneNoneFalseNoneFalse7418.880
232414768657NoneV-3 Item No 6.6Plain Cement Pavement Quality M30 grade Concrete (RMC) with OPC & GGBS laid without Paver Construction of un-reinforced plain cement concrete pavement using RMC M-30 grade with OPC @ 270 kg/m3 and GGBS@ 90kg/m3 (75:25 proportion) as per approved mix design procedure and thickness as per design, over a prepared sub base. The superplastisiser confirming to IS 9103-1999 Reaffirmed-2008, Coarse aggregates and Fine aggregate confirming to IS:383-2016, transported to site, laid in approved fixed side form work (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the form work). Spreading the concrete with shovels, rackers and compacted using needle, suitable plate vibrator and finished in a continuous operation including provision of separation membrane and Hessian cloth finishing to lines and grades complete including cost of all materials, labour, all lead & lift, loading charges as per specification & direction of Engineer - incharge of the work. (Groove cutting shall be paid seperately ---- etc., complete with all leadCum8233.128233.1224.0FalseNoneNoneFalseNoneFalse197594.880
232414868657NoneV-3 Item No 6.8.1Providing and laying 60mm thick factory made precast M -30 grade Cement Concrete Paver Block as per IRC SP 63:2018 & IS 15658 for Cycle Tracks & Pedestrian Footpaths of approved shape and colour, laid in required pattern and including over 30mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-incharge. (WMM/WBM Base to be paid separately if necessary as per relevant technical specification) ---- etc., complete with all leadSqm1298.051298.0596.0FalseNoneNoneFalseNoneFalse124612.80
232414968657NoneV-2 Item No 19.7.3Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. In cement mortar ---- etc., complete with all leadCum1250.651250.65366.6FalseNoneNoneFalseNoneFalse458488.290
232415068657NoneV-2 Item No 19.9.2Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineerin- charge. In cement mortar ---- etc., complete with all leadCum2046.732046.73384.31FalseNoneNoneFalseNoneFalse786578.80630
232415168657NoneV-3 Item No 1.1 aLoading and Unloading of Stone Boulder/Stone aggregates/Sand/Kankar/Moorum. (Tipper 10 m3) ---- etc., complete with all leadCum164.08164.08479.84FalseNoneNoneFalseNoneFalse78732.14720
232415268657NoneV-1 Item No 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for COLUMNS ---- etc., complete with all leadCum14138.8714138.8714.86FalseNoneNoneFalseNoneFalse210103.60820
232415368657NoneV-1 Item No 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Footing ---- etc., complete with all leadCum12475.4812475.4846.0141FalseNoneNoneFalseNoneFalse574047.9842680
232415468657NoneV-2 Item No 8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm450.91450.91570.0FalseNoneNoneFalseNoneFalse257018.70
232415568657NoneV-2 Item No 11.25.2Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete with all leadKg165.29165.29777.6FalseNoneNoneFalseNoneFalse128529.5040
232415668657NoneV-1 Item No 1.4.1Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m ---- etc., complete with all leadCum294.13294.1325.0FalseNoneNoneFalseNoneFalse7353.250
232415768657NoneV-1 Item No 1.1Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour complete as per specifications ---- etc., complete with all leadCum194.46194.4625.0FalseNoneNoneFalseNoneFalse4861.50
232415868657NoneV-2 Item No 13.31.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 20 mm nominal dia Pipes ---- etc., complete with all leadm294.13294.1320.0FalseNoneNoneFalseNoneFalse5882.60
232415968657NoneV-2 Item No 13.31.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 25 mm nominal dia Pipes ---- etc., complete with all leadm386.5386.512.0FalseNoneNoneFalseNoneFalse4638.00
232416068657NoneV-2 Item No 13.33.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 20 mm nominal dia Pipes ---- etc., complete with all leadm263.74263.7430.0FalseNoneNoneFalseNoneFalse7912.20
232416168657NoneV-2 Item No 13.33.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 25 mm nominal dia Pipes ---- etc., complete with all leadm359.76359.76140.0FalseNoneNoneFalseNoneFalse50366.40
232416268657NoneV-2 Item No 13.63Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0 cm X 4.0 cm with all fitting arrangements & all necessary accessories complete ---- etc., complete with all leadEach296.56296.5660.0FalseNoneNoneFalseNoneFalse17793.60
232416368657NoneV-2 Item No 13.64.1Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75mm nominal dia pipes ---- etc., complete with all leadm351.25351.2520.0FalseNoneNoneFalseNoneFalse7025.00
232416468657NoneV-2 Item No 13.64.2Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 110mm nominal dia pipes ---- etc., complete with all leadm30.3930.3920.0FalseNoneNoneFalseNoneFalse607.80
232416568657NoneV-2 Item No 13.64.3Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 150mm nominal dia pipes ---- etc., complete with all leadm933.43933.4350.0FalseNoneNoneFalseNoneFalse46671.50
232416668657NoneV-2 Item No 13.59Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete ---- etc., complete with all leadEach267.39267.3910.0FalseNoneNoneFalseNoneFalse2673.90
232416768657NoneV-2 Item No 13.22.1.1Providing and fixing PTMT grating of approved quality and colour. Circular type 100 mm nominal dia ---- etc., complete with all leadNos49.8349.8310.0FalseNoneNoneFalseNoneFalse498.30
232416868657NoneV-2 Item No 13.5.2Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 20 mm nominal bore ---- etc., complete with all leadNos381.64381.6420.0FalseNoneNoneFalseNoneFalse7632.80
232416968657NoneV-2 Item No 13.3.2Providing and fixing brass stop cock of approved quality 20 mm nominal bore ---- etc., complete with all leadNos370.7370.720.0FalseNoneNoneFalseNoneFalse7414.00
232417068657NoneV-2 Item No 13.4.1Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore ---- etc., complete with all leadNos667.25667.2520.0FalseNoneNoneFalseNoneFalse13345.00
232417168657NoneV-2 Item No 13.2.2Providing and fixing brass bib cock of approved quality : 20 mm nominal bore ---- etc., complete with all leadNos370.7370.720.0FalseNoneNoneFalseNoneFalse7414.00
232417268657NoneV-2 Item No 13.53Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 2 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5 ---- etc., complete with all leadNos6857.296857.295.0FalseNoneNoneFalseNoneFalse34286.450
232417368657NoneV-2 Item No 13.53Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 2 kg (weight of cover 23 kg and weight of frame 15 kg) With common burnt clay (non modular) bricks of class designation 3.5 ---- etc., complete with all leadNos12841.9212841.925.0FalseNoneNoneFalseNoneFalse64209.60
232417468657NoneV-2 Item No 14.28.2.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40mm dia pipes, From wash basin waste lines ---- etc., complete with all leadEach111.82111.8253.5FalseNoneNoneFalseNoneFalse5982.370
232417568657NoneV-2 Item No 14.32.3Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Oval shape 450x350 mm (outer dimensions) ---- etc., complete with all leadEach1295.621295.6210.0FalseNoneNoneFalseNoneFalse12956.20
232417668657NoneV-2 Item No 14.40.2600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. ---- etc., complete with all leadEach602.84602.8414.0FalseNoneNoneFalseNoneFalse8439.760
232417768657NoneV-2 Item No 14.2.1Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid ---- etc., complete with all leadEach585.82585.828.0FalseNoneNoneFalseNoneFalse4686.560
232417868657NoneV-2 Item No 20.44.2Providing & fixing White vitreous china water closet squatting pan (Indian type) along with "S" or "P" trap including dismantling of old WC seat and "S" or "P" trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge. Orissa pattern W.C Pan of size 580x440 mm ---- etc., complete with all leadEach4311.024311.026.0FalseNoneNoneFalseNoneFalse25866.120
232417968657NoneV-2 Item No 14.7.7White Vitreous China Flat back wash basin size 450x 300 mm with single 15mm C.P. brass pillar tap ---- etc., complete with all leadEach2551.122551.125.0FalseNoneNoneFalseNoneFalse12755.60
232418068657NoneV6 Item No 1.8.2Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends,junction box,elbows,screws at an interval of 300 mm as required. 25mm ---- etc., complete with all leadm42.5442.5440.0FalseNoneNoneFalseNoneFalse1701.60
232418168657NoneV6 Item No 1.9.2SupplyingPVCflexibleconduitpipe....mmdiafixingonsurfaceoverinvertedtaperedwoodenplugsorphillplugsorrawlplugsandclampedusingheavygaugesaddlesatanintervalof300mmusigNFscrews and on either end of the pipe terminated completely 25mm ---- etc., complete with all leadm26.7426.7410.0FalseNoneNoneFalseNoneFalse267.40
232418268657NoneV6 Item No 2.2.1SupplyingandwiringadoptingloopsysteminexistingPVCConduit/casingcappingcasingcappingusing2x1.5Sqmm(Phase&Neutral)&1x1.0sqmm(Earthwire)FRLSmultistrandPVCinsulatedcopperwire(confirmingtoIS-694:andlatestamendments)without controlswitchshallbefixedontheexistingplasticsheet/gangbox,theotherendofthewiresshallbeterminatedwithsufficientlooselength in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch box ---- etc., complete with all leadPoint326.94326.948.0FalseNoneNoneFalseNoneFalse2615.520
232418368657NoneV6 Item No 2.2.2SupplyingandwiringadoptingloopsysteminexistingPVCConduit/casingcappingcasingcappingusing2x1.5Sqmm(Phase&Neutral)&1x1.0sqmm(Earthwire)FRLSmultistrandPVCinsulatedcopperwire(confirmingtoIS-694:andlatestamendments)without controlswitchshallbefixedontheexistingplasticsheet/gangbox,theotherendofthewiresshallbeterminatedwithsufficientlooselength in a wood/PVC round block. complete for each outlet. Mediumpointabove3Mtrupto6Mtrfromtappingpointtooutletviaswitch box ---- etc., complete with all leadPoint460.64460.648.0FalseNoneNoneFalseNoneFalse3685.120
232418468657NoneV6 Item No 2.2.3SupplyingandwiringadoptingloopsysteminexistingPVCConduit/casingcappingcasingcappingusing2x1.5Sqmm(Phase&Neutral)&1x1.0sqmm(Earthwire)FRLSmultistrandPVCinsulatedcopperwire(confirmingtoIS-694:andlatestamendments)without controlswitchshallbefixedontheexistingplasticsheet/gangbox,theotherendofthewiresshallbeterminatedwithsufficientlooselength in a wood/PVC round block. complete for each outlet. Longpointabove6Mtrupto10Mtrfromtappingpointtooutletviaswitch box ---- etc., complete with all leadPoint674.55674.558.0FalseNoneNoneFalseNoneFalse5396.40
232418568657NoneV6 Item No 2.3.1Wiringforlighting/powercircuitusingoneofFRLSPVCinsulated1100Vgrade,multistrandcopperwirewithlowconductorresistancesinglecoreinopenorconcealedsystemofwiringwithspecifiedIS-694:2010 1 mm2 ---- etc., complete with all leadm23.0923.09300.0FalseNoneNoneFalseNoneFalse6927.00
232418668657NoneV6 Item No 2.3.3Wiringforlighting/powercircuitusingoneofFRLSPVCinsulated1100Vgrade,multistrandcopperwirewithlowconductorresistancesinglecoreinopenorconcealedsystemofwiringwithspecifiedIS-694:2010- 2.5 mm2 ---- etc., complete with all leadm51.0551.05200.0FalseNoneNoneFalseNoneFalse10210.00
232418768657NoneV6 Item No 2.3.4Wiringforlighting/powercircuitusingoneofFRLSPVCinsulated1100Vgrade,multistrandcopperwirewithlowconductorresistancesinglecoreinopenorconcealedsystemofwiringwithspecifiedIS-694:2010- 4 mm2 ---- etc., complete with all leadm76.5776.57200.0FalseNoneNoneFalseNoneFalse15314.00
232418868657NoneV6 Item No 2.3.5Wiringforlighting/powercircuitusingoneofFRLSPVCinsulated1100Vgrade,multistrandcopperwirewithlowconductorresistancesinglecoreinopenorconcealedsystemofwiringwithspecifiedIS-694:2010- 6 mm2 ---- etc., complete with all leadm111.82111.8220.0FalseNoneNoneFalseNoneFalse2236.40
232418968657NoneV6 Item No 3.14.1Supplying And fixing/replacing of 6/16/32A electricalaccessories on existing switch board. 6A SP Switch ---- etc., complete with all leadNos66.8566.8520.0FalseNoneNoneFalseNoneFalse1337.00
232419068657NoneV6 Item No 3.14.1Supplying And fixing/replacing of 6/16/32A electricalaccessories on existing switch board. 6A Two Way Switch ---- etc., complete with all leadNos85.0885.082.0FalseNoneNoneFalseNoneFalse170.160
232419168657NoneV6 Item No 3.14.2Supplying And fixing/replacing of 6/16/32A electricalaccessories on existing switch board. 6A Three Way 5 Pin Socket ---- etc., complete with all leadNos85.0885.084.0FalseNoneNoneFalseNoneFalse340.320
232419268657NoneV6 Item No 3.14.7Supplying And fixing/replacing of 6/16/32A electricalaccessories on existing switch board. 6A Batten Holder ---- etc., complete with all leadNos89.9489.948.0FalseNoneNoneFalseNoneFalse719.520
232419368657NoneV6 Item No 3.14.10Supplying And fixing/replacing of 6/16/32A electricalaccessories on existing switch board. 16A SP Switch ---- etc., complete with all leadNos159.22159.222.0FalseNoneNoneFalseNoneFalse318.440
232419468657NoneV6 Item No 3.14.12Supplying And fixing/replacing of 6/16/32A electricalaccessories on existing switch board. 16A Three Way 5 Pin Socket ---- etc., complete with all leadNos139.77139.772.0FalseNoneNoneFalseNoneFalse279.540
232419568657NoneV6 Item No 3.14.14Supplying And fixing/replacing of 6/16/32A electricalaccessories on existing switch board. 32A Bakelite DP ---- etc., complete with all leadNos281.97281.974.0FalseNoneNoneFalseNoneFalse1127.880
232419668657NoneV6 Item No 3.14.16Supplying And fixing/replacing of 6/16/32A electricalaccessories on existing switch board. Electronic stepped regulator. ---- etc., complete with all leadNos341.53341.536.0FalseNoneNoneFalseNoneFalse2049.180
232419768657NoneV6 Item No 3.12.2Supplying......wayplasticgangboxandfixingusingnecessarywooden/ rawl/phill plugs and screws. 2 to 4 Way Gang Box ---- etc., complete with all leadNos38.8938.898.0FalseNoneNoneFalseNoneFalse311.120
232419868657NoneV6 Item No 3.9Supplyingandfixinghylumplasticsheet3mmthickwithnecessarynitchesforfixingswitches,regulatorsetc.,andfixingonexistingwood or metal box using N. F. screws. ---- etc., complete with all leadSqm0.420.424500.0FalseNoneNoneFalseNoneFalse1890.00
232419968657NoneV6 Item No 3.10.2Supplying4mmthickwhiteplasticplateandcoveringforjunctionboxesofsize......mmconduitusingnecessarymachinescrews. 80/90 mm ---- etc., complete with all leadNos18.2318.232.0FalseNoneNoneFalseNoneFalse36.460
232420068657NoneV6 Item No 4.3Supplyanderectionof14FeetHeightStreetLightPole14FeetHeightStreetLightPoleonsuitablecementconcretefoundationwith2.5Feetheightdia5mmcastirondecorativeroundpedestalasperdesignweighingnotlessthan37Kgs,thepedestalshallbefittedwithClass'C'G.I.Pipe7Feetheight75mmouterdiaand7feetheighttoppieceouterdiaof65mmfixedbymeasureofthreading/welding/couplingcomplete. (excluding foundation). ---- etc., complete with all leadNos25037.2425037.245.0FalseNoneNoneFalseNoneFalse125186.20
232420168657NoneV6 Item No 6.1Supplyingexhaustfanof1440RPMof300mm(12")sizewithbracketbladescompleteforlightdutysuitabletooperateon230V50Hz, AC Supply. ---- etc., complete with all leadEach1813.381813.382.0FalseNoneNoneFalseNoneFalse3626.760
232420268657NoneV6 Item No 6.3.1Supplyingcapacitortypeceilingfancompletewithdownrodblades,shackle,canopiesetc,foroperationon230V,50cycles.SinglephaseACsupplyconformingtoISS-374-1979andwithdoubleballbearingsystem. 48" Sweep (1200 mm) Regular model ---- etc., complete with all leadEach3626.753626.754.0FalseNoneNoneFalseNoneFalse14507.00
232420368657NoneV6 Item No 11.3.1Supplyingof.....feet-PVCBattenwithintegratedLEDtube....WwithhighqualitydiffuserwithLifeof25000burninghours&70%lumenmaintenancewithCRI more than 80.PowerInput:220-240V@50/60Hz&Powerfactor more than 0.9alongwithCEapproved.2yearsWarrantyagainstanymanufacturingdefectworkingunderstandardelectrical condition. LED light fitting 1 x 2' - 9/10 W ---- etc., complete with all leadEach669.69669.694.0FalseNoneNoneFalseNoneFalse2678.760
232420468657NoneV6 Item No 11.3.3Supplyingof.....feet-PVCBattenwithintegratedLEDtube....WwithhighqualitydiffuserwithLifeof25000burninghours&70%lumenmaintenancewithCRI more than 80.PowerInput:220-240V@50/60Hz&Powerfactor more than 0.9alongwithCEapproved.2yearsWarrantyagainstanymanufacturingdefectworkingunderstandardelectrical condition. LED light fitting 1 x 4' - 36/40 W ---- etc., complete with all leadEach1542.341542.346.0FalseNoneNoneFalseNoneFalse9254.040
232420568657NoneV6 Item No 12.41Supplying&Fixingof250W/400WHighPressureSodiumVapourtubularLampwithXenonfilledgaswithluminousefficiencyofgreaterthan140lumen/Worinitiallumensofgreaterthan55000lumens&avgratedlifegreaterthan26000hrs.&minimumstartingtemperatureof(-)40degC&Hotrestriketime less than 60SecwithCCT2000K.Operatingvoltagerangefrom180Vto265V,50HzACpowerSupply ---- etc., complete with all leadEach2156.122156.125.0FalseNoneNoneFalseNoneFalse10780.60
232420668657NoneV6 Item No 11.15SupplyingandfixingofLEDBulkheadof10WwithIP65protectionandIK08impactresistancesuitableforsurfaceandwallmountingapplications. ---- etc., complete with all leadEach1023.371023.372.0FalseNoneNoneFalseNoneFalse2046.740
232420768657NoneV6 Item No 12.56Supplying,fixing,wiring,earthelectrodeforgroundingconduits,I.C.cutoutsandotherequipment'sonthemeterboardusing40mmdia2.90mmthickGIpipe2.5mlongburiedinapit.Thepitshouldbefilledwithequalproportionofsaltandcharcoal150mmall-roundthepipetocompletedepth.Theconnectionfromthepipetotheconduitetc.,istobeestablishedthroughGIwireofsizeasperlSIspecification7.3.3.ofIS732using12mmdiabolts,nuts,washersandchecknutsetc., the pipe shall have 16 through holes of 12 mm dia ---- etc., complete with all leadNos4266.054266.051.0FalseNoneNoneFalseNoneFalse4266.050
232420868657NoneV6 Item No 13.1.2SupplyingandFixingof........mmdiaclassAGIpipebracketupto2mslongbentatsuitableangleandfixingtothisbracketstreetlightfittingofallcapacitiestoGIorGIorrailorRCpole/wallusingsuitableclamps,bolts,andnutsandwiringusingsuitablecapacitywires. Using 32mm dia G.I.Pipe ---- etc., complete with all leadEach1270.091270.095.0FalseNoneNoneFalseNoneFalse6350.450
232420968657NoneV6 Item No 13.5Fixinghalogen/metalhalide/SVL/IL/LEDfloodlightfittingoverexistingpole/wallceilingincludingclamps,bolts,nutsandwiringusing suitable capacity wires. ---- etc., complete with all leadEach196.89196.895.0FalseNoneNoneFalseNoneFalse984.450
232421068657NoneV6 Item No 13.7.1Fixingalltypesandallcapacitiesoffluorescent/falseceiling/spotlight/CFL/LEDfittingsindooronthewall/ceiling/rafters/girdersusing23/0.0076"twintwistedPVCinsulatedwires,requiredNosofround blocks and clamps. On wall/ ceiling / Rafter / Girders ---- etc., complete with all leadEach148.28148.2850.0FalseNoneNoneFalseNoneFalse7414.00
232421168657NoneV6 Item No 13.1Fixingaceiling/Wallmountingfanofallcapacitiesandalltypestotheexisting'S''hookwithfanregulatortotheexistingboardtogetherwithsupplyingandfixing5A.ceilingrose,necessarylengthof23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. ---- etc., complete with all leadEach207.83207.8310.0FalseNoneNoneFalseNoneFalse2078.30
232421268657NoneV6 Item No 13.14Fixing one exhaust faninthenitch already left in the wall with bolts and nuts and 5A.ceiling rose withsufficient lengthof23/0.0076 inch PVC insulated twin core wire. ---- etc., complete with all leadEach597.98597.982.0FalseNoneNoneFalseNoneFalse1195.960
232421368657NoneV2 Item No 19.3Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. ---- etc., complete with all leadCum2948.562948.5674.37FalseNoneNoneFalseNoneFalse219284.40720
232421468657NoneV2 Item No 19.12.1Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking to the appropriate disposal area as per direction of Engineer-in-charge. 19.12.1 Of area 3 m² and below ---- etc., complete with all leadCum291.7291.7135.36FalseNoneNoneFalseNoneFalse39484.5120
232421568657NoneV2 Item No 19.22.1Dismantling tile work in floors and roofs laid in cement mortar including stacking material to the appropriate disposal area as per direction of Engineer-in-charge.For thickness of tiles 10 mm to 25 mm ---- etc., complete with all leadSqm58.3458.34352.0FalseNoneNoneFalseNoneFalse20535.680
232421668657NoneV-1 Item No 1.15.2Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work Depth exceeding 1.5 m, but not exceeding 3 m ---- etc., complete with all leadCum516.55516.5518.564FalseNoneNoneFalseNoneFalse9589.23420
232421768657NoneV-1 Item No 2.2.2.1Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for PEDESTALS ---- etc., complete with all leadCum8405.348405.341.764FalseNoneNoneFalseNoneFalse14827.019760
232421868657NoneV-3 Item No 17.4Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical Specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/Epoxy ---- etc., complete with all leadNos247.94247.9415.0FalseNoneNoneFalseNoneFalse3719.10
232421968657NoneV-2 Item No 8.83KSRB 4-5 :Providing Lath plaster with cement mortar 1:3 5cm thick with 6mm dia mild steel bars at 20cms. C to c both horizontally and vertically fixing chicken mesh for drop chejjas, facia, backing to cup board including cost of all materials, labour, providing and removing form work HOM of machineries, curing, complete as per specification. ---- etc., complete with all leadSqm1504.671504.676.633FalseNoneNoneFalseNoneFalse9980.476110
232422068657NoneV-2 Item No 5.4Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) ---- etc., complete with all leadCum7765.197765.191.26FalseNoneNoneFalseNoneFalse9784.13940
232422168657None15 Item No 4.21KSRB 4-2.12 : Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. Specification No . KBS ---- etc., complete with all leadRmtr38.9438.9460.0FalseNoneNoneFalseNoneFalse2336.40
232422268657NoneItem No 23Providing throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas & parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge. ---- etc., complete with all leadRmtr86.1486.1460.0FalseNoneNoneFalseNoneFalse5168.40
232422368657NoneV-2 Item No 12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- etc., complete with all leadCum120099.75120099.750.3023FalseNoneNoneFalseNoneFalse36306.1544250
232422468657NoneV-2 Item No 12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- etc., complete with all leadNos1234.851234.856.0FalseNoneNoneFalseNoneFalse7409.10
232422568657NoneV-2 Item No 12.60Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. ---- etc., complete with all leadNos1011.211011.216.0FalseNoneNoneFalseNoneFalse6067.260
232422668657NoneV-2 Item No 12.61Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete. ---- etc., complete with all leadNos754.76754.766.0FalseNoneNoneFalseNoneFalse4528.560
232422768657NoneV-2 Item No 12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete ---- etc., complete with all leadNos212.7212.712.0FalseNoneNoneFalseNoneFalse2552.40
232422868657NoneV-2 Item No 12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete ---- etc., complete with all leadNos134.91134.9112.0FalseNoneNoneFalseNoneFalse1618.920
232422968657NoneV-2 Item No 12.64Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms ---- etc., complete with all leadNos57.1257.126.0FalseNoneNoneFalseNoneFalse342.720
232423068657NoneV-2 Item No 12.75.1Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type) ---- etc., complete with all leadNos244.3244.318.0FalseNoneNoneFalseNoneFalse4397.40
232423168657NoneV-2 Item No 10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm ---- etc., complete with all leadNos72.9272.9236.0FalseNoneNoneFalseNoneFalse2625.120
232423268657NoneXI Item No 309 (0115)Providing & Fixing of corner beads of wooden door frame to wall including cost of materials, labour charges, complete as per specifications. ---- etc., complete with all leadRmtr15.015.031.2FalseNoneNoneFalseNoneFalse468.00
232423368657NoneV-2 Item No 12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial ---- etc., complete with all leadSqm4037.564037.5612.6FalseNoneNoneFalseNoneFalse50873.2560
232423468657NoneV-2 Item No 12.9Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all leadSqm8184.58184.518.42FalseNoneNoneFalseNoneFalse150758.490
232423568657NoneV-2 Item No 12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size - 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all leadSqm6950.876950.872.16FalseNoneNoneFalseNoneFalse15013.87920
232423668657NoneV-2 Item No 12.98Providing & fixing fiber glass reinforced plastic (FRP) Door frame of cross section 90mm x 45mm having single rebate of 32mm x 15mm to recieve shutter of 30mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyster resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The fram,e shall be covered with fiber glass form all sides. MS stay shall be provided at the bottom to steady the frame. ---- etc., complete with all leadm781.5781.519.8FalseNoneNoneFalseNoneFalse15473.70
232423768657NoneV-2 Item No 12.99.1Providing & fixing to existing door frames, 30mm thick Glass fibre reinforced plastic (FRP) panelled door shutter of required colour and approved brand and manufacture made with fire retardant grade unsaturated polyster resin, moulded to 3mm thick FRP Laminate for forming hollow railsand styles with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings cast monolithically with 5mm thick FRP Laminate for panels conforming to IS 14856 Including fixing to frames ---- etc., complete with all leadSqm3894.143894.146.3FalseNoneNoneFalseNoneFalse24533.0820
232423868657None118 Item No 8.16.3Providing and fixing plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per Sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment ) ---- etc., complete with all leadRmtr51.9251.92209.0FalseNoneNoneFalseNoneFalse10851.280
232423968657NoneV-2 Item No 8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm256.45256.45127.0386FalseNoneNoneFalseNoneFalse32579.048970
232424068657NoneV-2 Item No 15.1Providing and Applying PU based Elastomeric Liquid Applied PU Waterproofing Membrane single component, cold applied, water based acrylic PU dispersion with highly elastic and UV resistant water proofing treatment to the Existing Roof surface/Chajjas/Sunken portion of WC:Bathroom applied @ 1.2L/per m2,having tensile strength greater than 1.5N/mm2, elongation greater than 300% with solid content not less than 60% in 2 coats including surface preparation, priming the surface with water based acrylic primer @0.1 L/m2, and spreading 60 gsm geotextile between two top coats completely as per specification. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. Polyurethane based Single Component for New Surface ---- etc., complete with all leadCum992.98992.9818.279FalseNoneNoneFalseNoneFalse18150.681420
232424168657None70 Item No 10.5.2Bore Packing : Filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulaion on the bore. Including all labour charges tools and equipments, all complete as per the manufacturer. ---- etc., complete with all leadSqm283.2283.215.0FalseNoneNoneFalseNoneFalse4248.00
232424268657NoneV-2 Item No 8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. ---- etc., complete with all leadRmtr63.263.2224.8FalseNoneNoneFalseNoneFalse14207.360
232424368657NoneV-2 Item No 9.23Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : ** Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. ---- etc., complete with all leadSqm2997.182997.1818.4875FalseNoneNoneFalseNoneFalse55410.365250
232424468657NoneV-2 Item No 11.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete with all leadKg686.7686.780.4FalseNoneNoneFalseNoneFalse55210.680
232424568657NoneV-2 Item No 8.4Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm139.77139.7720.58FalseNoneNoneFalseNoneFalse2876.46660
232424668657NoneV-2 Item No 8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm64.4264.4230.24FalseNoneNoneFalseNoneFalse1948.06080
232424768657NoneV-1 Item No 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for COLUMNS ---- etc., complete with all leadCum14276.1414276.142.27FalseNoneNoneFalseNoneFalse32406.83780
232424868657NoneV-1 Item No 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RCC BEAMS, RCC SLAB and LINTEL ---- etc., complete with all leadCum13436.3713436.372.9166FalseNoneNoneFalseNoneFalse39188.5167420
232424968657NoneV-1 Item No 2.1.4Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all leadCum11062.7811062.783.8104FalseNoneNoneFalseNoneFalse42153.6169120
232425068657NoneV-2 Item No 11.32Providing Thermo-Mechanically Treated bars of grade Fe-550D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) ---- etc., complete with all leadTonne109781.63109781.631.4824FalseNoneNoneFalseNoneFalse162740.2883120
232425168657None15 Item No 4.21KSRB 4-2.12 : Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. Specification No . KBS ---- etc., complete with all leadRmtr40.1140.113.7FalseNoneNoneFalseNoneFalse148.4070
232425268657NoneItem No 23Providing throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas & parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge. ---- etc., complete with all leadRmtr88.7288.7276.25FalseNoneNoneFalseNoneFalse6764.90
232425368657NoneV-2 Item No 6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete with all leadSqm1607.631607.6397.354FalseNoneNoneFalseNoneFalse156509.211020
232425468657NoneV-2 Item No 12.9Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all leadSqm8263.968263.961.8FalseNoneNoneFalseNoneFalse14875.1280
232425568657NoneV-2 Item No 11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- etc., complete with all leadKg206.17206.1737.8FalseNoneNoneFalseNoneFalse7793.2260
232425668657NoneV-2 Item No 11.5.1Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete with all leadSqm4491.554491.552.52FalseNoneNoneFalseNoneFalse11318.7060
232425768657NoneV-2 Item No 8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge... ( Inside) ---- etc., complete with all leadSqm382.89382.8924.804FalseNoneNoneFalseNoneFalse9497.203560
232425868657NoneV-2 Item No 8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete with all leadSqm122.72122.7242.9661FalseNoneNoneFalseNoneFalse5272.7997920
232425968657NoneV-2 Item No 8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. ( Outside) ---- etc., complete with all leadSqm428.29428.29203.1865FalseNoneNoneFalseNoneFalse87022.7460850
232426068657NoneV-2 Item No 15.1Providing and Applying PU based Elastomeric Liquid Applied PU Waterproofing Membrane single component, cold applied, water based acrylic PU dispersion with highly elastic and UV resistant water proofing treatment to the Existing Roof surface/Chajjas/Sunken portion of WC:Bathroom applied @ 1.2L/per m2,having tensile strength greater than 1.5N/mm2, elongation greater than 300% with solid content not less than 60% in 2 coats including surface preparation, priming the surface with water based acrylic primer @0.1 L/m2, and spreading 60 gsm geotextile between two top coats completely as per specification. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. Polyurethane based Single Component for New Surface ---- etc., complete with all leadSqm1002.621002.62165.0FalseNoneNoneFalseNoneFalse165432.30
232426168657NoneV-2 Item No 8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm155.85155.8542.9661FalseNoneNoneFalseNoneFalse6696.2666850
232426268657NoneV-2 Item No 8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm191.44191.44203.1865FalseNoneNoneFalseNoneFalse38898.023560
232426368657NoneV-2 Item No 8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm61.3661.363.9FalseNoneNoneFalseNoneFalse239.3040
232426468657NoneV-2 Item No 8.4Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm141.13141.133.9FalseNoneNoneFalseNoneFalse550.4070
232426568657NoneW.S & UGD SR Item No 647PVC pipe - OD 110mm and 6 Kg/sqcm (Sl No 647 Page No A-44) ---- etc., complete with all leadRmtr312.94312.94216.0FalseNoneNoneFalseNoneFalse67595.040
232426668657NoneV-2 Item No 14.28.2.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40mm dia ---- etc., complete with all leadm111.82111.8210.0FalseNoneNoneFalseNoneFalse1118.20
232426768657NoneV-5 Item No 16.7.4Providing and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make including trench excavation and refilling etc. for EXTERNAL WORKS with: 50mm nominal bore pipes ---- etc., complete with all leadm168.94168.948.0FalseNoneNoneFalseNoneFalse1351.520
232426868657NoneV-5 Item No 657PVC pipe - OD 75mm and 6 Kg/sqcm (Sl.No 657 Page No A-44) ---- etc., complete with all leadm149.49149.49135.0FalseNoneNoneFalseNoneFalse20181.150
232426968657NoneV-5 Item No 647PVC pipe - OD 110mm and 6 Kg/sqcm (Sl.No 647 Page No A-44) ---- etc., complete with all leadm309.93309.93100.0FalseNoneNoneFalseNoneFalse30993.00
232427068657NoneV-2 Item No 13.47Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 75mm diameter ---- etc., complete with all leadm239.43239.4320.0FalseNoneNoneFalseNoneFalse4788.60
232427168657None2018-19 SR Item No 37.28.1Drilling holes of 2.50 cms dia (roof/chajja/stone). in slabs upto 7.50 cms thick. (CIVIL SR 2018-19) ---- etc., complete with all leadNos159.22159.2210.0FalseNoneNoneFalseNoneFalse1592.20
232427268657None2018-19 SR Item No 37.28.2Drilling holes of 2.50 cms dia (roof/chajja/stone). in slabs upto 10 cms thick. (CIVIL SR 2018-19) ---- etc., complete with all leadNos190.82190.825.0FalseNoneNoneFalseNoneFalse954.10
232427368657NoneV-2 Item No 14.31Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. ---- etc., complete with all leadNos1180.151180.154.0FalseNoneNoneFalseNoneFalse4720.60
232427468657NoneV-2 Item No 13.9.2Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter ---- etc., complete with all leadNos339.1339.14.0FalseNoneNoneFalseNoneFalse1356.40
232427568657NoneV-2 Item No 14.22BProviding and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. ---- etc., complete with all leadNos6760.056760.051.0FalseNoneNoneFalseNoneFalse6760.050
232427668657NoneV-2 Item No 14.35Providing and fixing vitreous china dual purpose closet suitable for use as squatting pan or European type water closet (Anglo Indian W.C pan) with seat & lid fixed with C.P. brass hinges and rubber buffers, 10 litre low level flushing cistern with fitting and brackets, 40 mm flush bend, 20 mm over flow pipe, with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: ---- etc., complete with all leadNos10491.3310491.332.0FalseNoneNoneFalseNoneFalse20982.660
232427768657NoneV-2 Item No 14.10.1.4Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board-510x1040 mm bowl depth 178 mm ---- etc., complete with all leadNos5872.815872.814.0FalseNoneNoneFalseNoneFalse23491.240
232427868657NoneV-2 Item No 166C.P. Brass stop cock (concealed) 15 mm Sl.no.- 166 Page No A-16 ---- etc., complete with all leadNos638.09638.0912.0FalseNoneNoneFalseNoneFalse7657.080
232427968657NoneV-2 Item No 14.7.10Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps ---- etc., complete with all leadNos3745.863745.867.0FalseNoneNoneFalseNoneFalse26221.020
232428068657NoneV-2 Item No 13.32.1Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal dia Pipes ---- etc., complete with all leadm375.56375.56100.0FalseNoneNoneFalseNoneFalse37556.00
232428168657NoneV-2 Item No 13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia Pipes ---- etc., complete with all leadm460.64460.6475.0FalseNoneNoneFalseNoneFalse34548.00
232428268657NoneV-2 Item No 13.32.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal dia Pipes ---- etc., complete with all leadm579.75579.7525.0FalseNoneNoneFalseNoneFalse14493.750
232428368657NoneV-2 Item No 13.32.4Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32 mm nominal dia Pipes ---- etc., complete with all leadm676.98676.9825.0FalseNoneNoneFalseNoneFalse16924.50
232428468657NoneV-2 Item No 13.31.5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.internal work - exposed on wall 40 mm nominal dia Pipes ---- etc., complete with all leadm651.45651.4525.0FalseNoneNoneFalseNoneFalse16286.250
232428568657NoneV-2 Item No 13.33.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 50 mm nominal dia Pipes ---- etc., complete with all leadm876.3876.375.0FalseNoneNoneFalseNoneFalse65722.50
232428668657NoneV-2 Item No 109Brass full way valve with C.I. wheel (screwed end) 25 mm dia. (Sl No 109 Page No .A-15) ---- etc., complete with all leadNos455.78455.7820.0FalseNoneNoneFalseNoneFalse9115.60
232428768657NoneV-2 Item No 110Brass full way valve with C.I. wheel (screwed end) 32 mm dia. (Sl No 109 Page No .A-15) ---- etc., complete with all leadNos504.39504.3920.0FalseNoneNoneFalseNoneFalse10087.80
232428868657NoneV-2 Item No 86Brass bib-cock 15 mm dia ---- etc., complete with all leadNos194.46194.466.0FalseNoneNoneFalseNoneFalse1166.760
232428968657NoneV-2 Item No 8.5.1Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix 1:3 (1 cement: 3 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm444.84444.843.9FalseNoneNoneFalseNoneFalse1734.8760
232429068657NoneV-2 Item No 13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank. ---- etc., complete with all leadLtr10.9410.941000.0FalseNoneNoneFalseNoneFalse10940.00
232429168657NoneV-1 Item No 1.5Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depth ---- etc., complete with all leadCum278.33278.3387.0FalseNoneNoneFalseNoneFalse24214.710
232429268657NoneV-5 Item No 10.2.4Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:( For external Sanitary Work ). Pipes of SN4, 160mm dia. ---- etc., complete with all leadm700.07700.0760.0FalseNoneNoneFalseNoneFalse42004.20
232429368657NoneV-5 Item No 10.2.5Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:( For external Sanitary Work ). Pipes of SN4, 200mm dia. ---- etc., complete with all leadm1010.01010.060.0FalseNoneNoneFalseNoneFalse60600.00
232429468657NoneV-5 Item No 16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.. ---- etc., complete with all leadNos6628.796628.7910.0FalseNoneNoneFalseNoneFalse66287.90
232429568657None2018-19 SR 12.112.2Providing stoneware gully trap of approved quality and make fixing in M-15 and plastering with CM 1:3 wherever necessary.( Rate includes cost of all materials, fixtures and lead).15cms x 10cms. (SR. 2018-19) ---- etc., complete with all leadNos340.31340.3110.0FalseNoneNoneFalseNoneFalse3403.10
232429668657NoneV-5 Item No 16.37Providing and fixing 150mm dia. Cast Iron pipe for ventilatiing shaft 5 M high with specials and cowl and with suitable grips in CC 1:2:4 pillar using 10mm to 20mm graded hard granite, with 15 cms. thick cement concrete 1:2:4 around upto 1.22 M above the GLR and with a foundation base of 90 x 90 x 90 cms. plastered with 12mm thick CM 1:3 to all exposed faces and linking the shaft to the manholes by means of 150mm dia. GSW pipes and specials, jointing with tar dipped hemp 1:1.5 CM caulking, curing. The cost include all lead and lifts for all materials, earth work excavations and refilling in all strata, disposal of surplus earth etc. complete ---- etc., complete with all leadNos25629.1425629.141.0FalseNoneNoneFalseNoneFalse25629.140
232429768657NoneV-2 Item No 13.23.5Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. 50 mm nominal bore, 242mm long, weighing not less than 1240 g ---- etc., complete with all leadNos1633.51633.52.0FalseNoneNoneFalseNoneFalse3267.00
232429868657NoneELECTRICAL SR CODE No 2.2.1Point wiring using Copper wire without switch Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point up to 3Mtr from tapping point to out let via switch box ---- etc., complete with all leadPoint326.94326.9422.0FalseNoneNoneFalseNoneFalse7192.680
232429968657NoneELECTRICAL SR CODE No 2.2.2Point wiring using Copper wire without switch Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch box ---- etc., complete with all leadPoint460.64460.6418.0FalseNoneNoneFalseNoneFalse8291.520
232430068657NoneELECTRICAL SR CODE No 2.2.3Point wiring using Copper wire without switch Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switch box ---- etc., complete with all leadPoint674.55674.5520.0FalseNoneNoneFalseNoneFalse13491.00
232430168657NoneELECTRICAL SR CODE No 3.4.1Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-2Way ---- etc., complete with all leadEach167.73167.7310.0FalseNoneNoneFalseNoneFalse1677.30
232430268657NoneELECTRICAL SR CODE No 3.4.2Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3Way ---- etc., complete with all leadEach193.25193.255.0FalseNoneNoneFalseNoneFalse966.250
232430368657NoneELECTRICAL SR CODE No 3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5Way ---- etc., complete with all leadEach215.13215.135.0FalseNoneNoneFalseNoneFalse1075.650
232430468657NoneELECTRICAL SR CODE No 3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6Way ---- etc., complete with all leadEach267.39267.396.0FalseNoneNoneFalseNoneFalse1604.340
232430568657NoneELECTRICAL SR CODE No 3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8Way ---- etc., complete with all leadEach317.22317.222.0FalseNoneNoneFalseNoneFalse634.440
232430668657NoneELECTRICAL SR CODE No 3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way ---- etc., complete with all leadEach387.71387.712.0FalseNoneNoneFalseNoneFalse775.420
232430768657NoneELECTRICAL SR CODE No 3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 Module ---- etc., complete with all leadEach166.51166.5130.0FalseNoneNoneFalseNoneFalse4995.30
232430868657NoneELECTRICAL SR CODE No 3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3 Module ---- etc., complete with all leadEach195.68195.6810.0FalseNoneNoneFalseNoneFalse1956.80
232430968657NoneELECTRICAL SR CODE No 3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4Moudule ---- etc., complete with all leadEach212.7212.715.0FalseNoneNoneFalseNoneFalse3190.50
232431068657NoneELECTRICAL SR CODE No 3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6Moudule ---- etc., complete with all leadEach284.4284.46.0FalseNoneNoneFalseNoneFalse1706.40
232431168657NoneELECTRICAL SR CODE No 3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8Moudule ---- etc., complete with all leadEach345.17345.1710.0FalseNoneNoneFalseNoneFalse3451.70
232431268657NoneELECTRICAL SR CODE No 3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10Moudule ---- etc., complete with all leadEach418.1418.110.0FalseNoneNoneFalseNoneFalse4181.00
232431368657NoneELECTRICAL SR CODE No 3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way. ---- etc., complete with all leadEach123.97123.9710.0FalseNoneNoneFalseNoneFalse1239.70
232431468657NoneELECTRICAL SR CODE No 3.6.2Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps Two way. ---- etc., complete with all leadEach201.76201.765.0FalseNoneNoneFalseNoneFalse1008.80
232431568657NoneELECTRICAL SR CODE No 3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A three way socket. ---- etc., complete with all leadEach207.83207.835.0FalseNoneNoneFalseNoneFalse1039.150
232431668657NoneELECTRICAL SR CODE No 3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator Two Module ---- etc., complete with all leadEach433.9433.96.0FalseNoneNoneFalseNoneFalse2603.40
232431768657NoneELECTRICAL SR CODE No 3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32A DP switch ---- etc., complete with all leadEach396.22396.223.0FalseNoneNoneFalseNoneFalse1188.660
232431868657NoneELECTRICAL SR CODE No 3.6.11Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16A universal socket ---- etc., complete with all leadEach286.83286.833.0FalseNoneNoneFalseNoneFalse860.490
232431968657NoneELECTRICAL SR CODE No 3.6.12Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. TV/Telephone socket ---- etc., complete with all leadEach189.6189.61.0FalseNoneNoneFalseNoneFalse189.60
232432068657NoneELECTRICAL SR CODE No 12.2.1Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Dong Bell ---- etc., complete with all leadEach298.99298.991.0FalseNoneNoneFalseNoneFalse298.990
232432168657NoneELECTRICAL SR CODE No 1.12Supplying and Fixing Metal Fan Box with Round Hook. ---- etc., complete with all leadNo142.2142.26.0FalseNoneNoneFalseNoneFalse853.20
232432268657NoneELECTRICAL SR CODE No 1.2.1Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 19/20mm dia 2mm thick ---- etc., complete with all leadMtr80.2280.22200.0FalseNoneNoneFalseNoneFalse16044.00
232432368657NoneELECTRICAL SR CODE No 1.2.2Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 25mm dia 2mm thick ---- etc., complete with all leadMtr94.894.8200.0FalseNoneNoneFalseNoneFalse18960.00
232432468657NoneELECTRICAL SR CODE No 1.2.3Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 32mm dia 2.5mm thick ---- etc., complete with all leadMtr125.19125.1950.0FalseNoneNoneFalseNoneFalse6259.50
232432568657NoneELECTRICAL SR CODE No 1.3.1Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19/20mm dia 2mm thick ---- etc., complete with all leadMtr82.6582.6550.0FalseNoneNoneFalseNoneFalse4132.50
232432668657NoneELECTRICAL SR CODE No 1.3.2Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 25mm dia 2mm thick ---- etc., complete with all leadMtr96.0296.0240.0FalseNoneNoneFalseNoneFalse3840.80
232432768657NoneELECTRICAL SR CODE No 1.3.3Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 32mm dia 2.5mm thick ---- etc., complete with all leadMtr120.32120.3220.0FalseNoneNoneFalseNoneFalse2406.40
232432868657NoneELECTRICAL SR CODE No 2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper with low conductor resistance single core cable in open or concealed system of wiring with specified IS-694:1990 & comfirming to 1.5 sqmm ---- etc., complete with all leadMtr31.631.6250.0FalseNoneNoneFalseNoneFalse7900.00
232432968657NoneELECTRICAL SR CODE No 2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper with low conductor resistance single core cable in open or concealed system of wiring with specified IS-694:1990 & comfirming to 2.5 sqmm ---- etc., complete with all leadMtr51.0551.05250.0FalseNoneNoneFalseNoneFalse12762.50
232433068657NoneELECTRICAL SR CODE No 2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper with low conductor resistance single core cable in open or concealed system of wiring with specified IS-694:1990 & comfirming to 4 sqmm ---- etc., complete with all leadMtr76.5776.57100.0FalseNoneNoneFalseNoneFalse7657.00
232433168657NoneELECTRICAL SR CODE No 2.3.5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper with low conductor resistance single core cable in open or concealed system of wiring with specified IS-694:1990 & comfirming to 6 sqmm ---- etc., complete with all leadMtr111.82111.8250.0FalseNoneNoneFalseNoneFalse5591.00
232433268657NoneELECTRICAL SR CODE No 5.19.8Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure Double Door 8 Way SP & N ---- etc., complete with all leadEach2253.352253.351.0FalseNoneNoneFalseNoneFalse2253.350
232433368657NoneELECTRICAL SR CODE No 5.19.9Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure Double Door 12 Way SP & N ---- etc., complete with all leadEach2830.672830.672.0FalseNoneNoneFalseNoneFalse5661.340
232433468657NoneELECTRICAL SR CODE No 5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32A SP ---- etc., complete with all leadEach504.39504.395.0FalseNoneNoneFalseNoneFalse2521.950
232433568657NoneELECTRICAL SR CODE No 5.20.1Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board 16-25 A 2 pole ---- etc., complete with all leadEach5198.275198.272.0FalseNoneNoneFalseNoneFalse10396.540
232433668657NoneELECTRICAL SR CODE No 51.04Rod type of earthing using 40 mm Dia, 3 Mtr long MS rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal & connected to equipment ground terminal using PVC Al wire as specified. ( Item No 51.04, SL No 392 ESCOMs SR 2023-24) ---- etc., complete with all leadNo2639.852639.852.0FalseNoneNoneFalseNoneFalse5279.70
232433768657NoneELECTRICAL SR CODE No 54.05Bentonite clay slurry for earthing in 50 Kg Bag ( Item No 54.05, SL No 393 ESCOMs SR 2023-24) ---- etc., complete with all leadBag447.27447.271.0FalseNoneNoneFalseNoneFalse447.270
232433868657NoneELECTRICAL SR CODE No 6.3.1Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required 25x3mm GI strip .(Item No 6.3.1 Electrical SR 2019-20) ---- etc., complete with all leadMtr91.1691.1612.0FalseNoneNoneFalseNoneFalse1093.920
232433968657NoneELECTRICAL SR CODE No 32.051.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975. 16 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm) ( Item No 32.05, SL No 201 ESCOMs SR 2023-24) ---- etc., complete with all leadKm172394.77172394.770.2FalseNoneNoneFalseNoneFalse34478.9540
232434068657NoneELECTRICAL SR CODE No 21.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff. 2.5 to 25 Sqmm. ( Item No 21.05, SL No 174 ESCOMs SR 2023-24) ---- etc., complete with all leadKm25384.8425384.840.2FalseNoneNoneFalseNoneFalse5076.9680
232434168657NoneELECTRICAL SR CODE No 29.03Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr,Supplying and Displaying necessary Danger Boards and Lighting, Using sightRails and Sign Boards at every 100 Mtr wherever necessary as directed. In soil (hard) ( Item No 29.03 ESCOMs SR 2023-24) ---- etc., complete with all leadCum472.79472.7925.0FalseNoneNoneFalseNoneFalse11819.750
232434268657NoneELECTRICAL SR CODE No 8.2.2Supplying and drawing PVC flexible one pair telepone unarmoured tinned copper cable. (91/11.2) 2 Pair ---- etc., complete with all leadMtr25.5225.521.0FalseNoneNoneFalseNoneFalse25.520
232434368657NoneELECTRICAL SR CODE No 8.3Supplying and drawing PVC insulated gas injected physical foam jelly flooded co-axial TV cable.RG-6. ---- etc., complete with all leadRmtr53.4853.4815.0FalseNoneNoneFalseNoneFalse802.20
232434468657NoneELECTRICAL SR CODE No 11.3.2Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI more than 80. Power Input: 220-240V @ 50/60Hz & Power factor more than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 w ---- etc., complete with all leadEach838.63838.6316.0FalseNoneNoneFalseNoneFalse13418.080
232434568657NoneELECTRICAL SR CODE No 11.5.2Supply of round/square recess/surface mounted rolling type LED Down light with .......W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI more than 80. Power Input: 220-240V @ 50/60Hz & Power factor more than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10-12W ---- etc., complete with all leadEach1075.631075.6316.0FalseNoneNoneFalseNoneFalse17210.080
232434668657NoneELECTRICAL SR CODE No 11.11.3Supplying & fixing of retrofit type - LED bulb.......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI more than 70%. efficacy more than 80 lumen per watt, life more than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF more than 0.95, power loss should less than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7 W, 6500K ---- etc., complete with all leadEach181.09181.095.0FalseNoneNoneFalseNoneFalse905.450
232434768657NoneELECTRICAL SR CODE No 11.11.5Supplying & fixing of retrofit type - LED bulb.......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI more than 70%. efficacy more than 80 lumen per watt, life more than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF more than 0.95, power loss should less than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 12 W, 6500K ---- etc., complete with all leadEach326.94326.942.0FalseNoneNoneFalseNoneFalse653.880
232434868657NoneELECTRICAL SR CODE No 11.11.7Supplying & fixing of retrofit type - LED bulb.......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI more than 70%. efficacy more than 80 lumen per watt, life more than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF more than 0.95, power loss should less than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 18 W, 6500K ---- etc., complete with all leadEach517.76517.762.0FalseNoneNoneFalseNoneFalse1035.520
232434968657NoneELECTRICAL SR CODE No 12.27Supplying & Fixing of Special Type pigmy and candle lamp. Operating voltage range from 180V to 265V, 50Hz AC power Supply ---- etc., complete with all leadNos63.263.22.0FalseNoneNoneFalseNoneFalse126.40
232435068657NoneELECTRICAL SR CODE No 12.46Supplying & Fixing of 70-150 Watts lamp holder 2 Pin ---- etc., complete with all leadEach76.5776.579.0FalseNoneNoneFalseNoneFalse689.130
232435168657NoneELECTRICAL SR CODE No 11.8.1Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT more than 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire more than IK08. Power Factor more than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency more than 130lm/w, nominal CRI more than 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 25watts ---- etc., complete with all leadNos2947.352947.352.0FalseNoneNoneFalseNoneFalse5894.70
232435268657NoneELECTRICAL SR CODE No 6.1Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. ---- etc., complete with all leadEach1813.381813.383.0FalseNoneNoneFalseNoneFalse5440.140
232435368657NoneELECTRICAL SR CODE No 6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm) Regular model ---- etc., complete with all leadEach3626.753626.756.0FalseNoneNoneFalseNoneFalse21760.50
232435468657NoneELECTRICAL SR CODE No 13.7.1Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders ---- etc., complete with all leadEach148.28148.2820.0FalseNoneNoneFalseNoneFalse2965.60
232435568657NoneELECTRICAL SR CODE No 13.10.Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. ---- etc., complete with all leadEach207.83207.836.0FalseNoneNoneFalseNoneFalse1246.980
232435668657NoneELECTRICAL SR CODE No 13.13Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. ---- etc., complete with all leadEach859.29859.293.0FalseNoneNoneFalseNoneFalse2577.870
232435768657NoneELECTRICAL SR CODE No 13.4.1Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. Length ---- etc., complete with all leadEach1775.71775.72.0FalseNoneNoneFalseNoneFalse3551.40
232435868657NoneELECTRICAL SR CODE No 13.5Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. ---- etc., complete with all leadEach196.89196.892.0FalseNoneNoneFalseNoneFalse393.780
232435968657NoneELECTRICAL SR CODE No 5.42.2Fabricating supplying and mounting MS box made out....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 16SWG ---- etc., complete with all leadSq CM0.520.5240000.0FalseNoneNoneFalseNoneFalse20800.00
232436068657NoneELECTRICAL SR CODE No 5.40.1Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 100Amps 4x30x6mm Aluminum Strips ---- etc., complete with all leadMtr2995.962995.963.0FalseNoneNoneFalseNoneFalse8987.880
232436168657NoneELECTRICAL SR CODE No 5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- etc., complete with all leadMtr370.7370.72.0FalseNoneNoneFalseNoneFalse741.40
232436268657NoneELECTRICAL SR CODE No 5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., complete with all leadMtr918.84918.842.0FalseNoneNoneFalseNoneFalse1837.680
232436368657NoneELECTRICAL SR CODE No 5.15.9Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR POLE 100 A 25 kA ---- etc., complete with all leadEach10315.110315.11.0FalseNoneNoneFalseNoneFalse10315.10
232436468657NoneELECTRICAL SR CODE No 5.18.8Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 40 A TPN ---- etc., complete with all leadEach3699.683699.681.0FalseNoneNoneFalseNoneFalse3699.680
232436568657NoneELECTRICAL SR CODE No 5.18.4Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32A DP ---- etc., complete with all leadEach898.18898.184.0FalseNoneNoneFalseNoneFalse3592.720
232436668657NoneELECTRICAL SR CODE No 5.7.2Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers 32 A ---- etc., complete with all leadEach292.91292.914.0FalseNoneNoneFalseNoneFalse1171.640
232436768657NoneELECTRICAL SR CODE No 5.7.3Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers 63 A ---- etc., complete with all leadEach487.38487.381.0FalseNoneNoneFalseNoneFalse487.380
232436868657NoneELECTRICAL SR CODE No 5.3Supplying, fixing and wiring electronic 5 to 20Amps single phase Class-1 Accuracy with Temper Proof Energy Meter ---- etc., complete with all leadEach1677.251677.253.0FalseNoneNoneFalseNoneFalse5031.750
232436968657NoneELECTRICAL SR CODE No 5.33Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy ---- etc., complete with all leadEach11321.4511321.451.0FalseNoneNoneFalseNoneFalse11321.450
232437068657NoneELECTRICAL SR CODE No 5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., complete with all leadEach625.93625.933.0FalseNoneNoneFalseNoneFalse1877.790
232437168657NoneELECTRICAL SR CODE No 5.34Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound ---- etc., complete with all leadEach683.05683.053.0FalseNoneNoneFalseNoneFalse2049.150
232437268657NoneELECTRICAL SR CODE No 7.1.3Supplying ...litres capacity vertical/horizontal type wall mounting Electrical water heater with 22 SWG copper/SS sheet metal inner Container tinned inside and anticorrosive paint outside and 20 SWG M.S. sheet metal outer cover filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate .2KW capacity element with a neon indicator fitted with 20A capacity 25 to 85 degree Centigrade range thermostat. The water heater shall completely be wired with 40/0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting. 25Litres ---- etc., complete with all leadEach12448.1312448.132.0FalseNoneNoneFalseNoneFalse24896.260
232437368657NoneELECTRICAL SR CODE No 7.3.2Supplying, installation, testing and commissioning of solar hot water heater comprising of solar Flat Plate Collector (FPC) of size 2120x1040x100mm and stainless steel hot water storage tank with stainless steel heat exchanger absorber made of copper sheet and copper tube of following capacity aluminium box collector with appropriate capacity electrical back up arrangement excluding inlet and out let pipes. SS Model with 100mm thick of 48Kg/M3density Rock wool insulation with 22SWG Aluminium cladding. 200 L Capacity ---- etc., complete with all leadEach57019.2857019.282.0FalseNoneNoneFalseNoneFalse114038.560
17065146690000NoneNoneBuildingsUpgradation of infrastructure facilities to the General Hospital and Staff quarters at Bagepalli General Hospital in Chikkaballpura District 2 Construction of New PHC after demolishing the old building at G.Madepalli in Bagepalli taluk Chikkabalalpura District 3 Upgradation of infrastructure facilities to the General Hospital and Staff quarters at Gudibande General Hospital in Chikkaballpura District59093569.66
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
232477568668NoneV2 Item No 19.3Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. ---- etc., complete with all leadCum2862.682862.6818.59FalseNoneNoneFalseNoneFalse53217.22120
232507068668NoneV2 Item No 19.55Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground to the appropriate disposal area as per direction of Engineer-in-charge. ---- etc., complete with all leadSqm44.9744.97262.3FalseNoneNoneFalseNoneFalse11795.6310
232461868668NoneV2 Item No19.55Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground to the appropriate disposal area as per direction of Engineer-in-charge. ---- etc., complete with all leadSqm44.9744.972730.9FalseNoneNoneFalseNoneFalse122808.5730
232477668668NoneV2 Item No 19.7.3Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. In cement mortar ---- etc., complete with all leadCum1214.221214.2291.51FalseNoneNoneFalseNoneFalse111113.27220
232507168668NoneV2 Item No 20.89Repairs to plaster in patches of 2.5 m2 and less in walls, ceilings 10 to 20mm thick in cement mortar 1:4 including cutting the patches in proper shape and replastering the surface of the wall including disposal of rubbish with a lead of 50m including curing cost of materials, labour, complete as per specification ---- etc., complete with all leadSqm460.64460.64112.5FalseNoneNoneFalseNoneFalse51822.00
232461968668NoneV2 Item No20.89Repairs to plaster in patches of 2.5 m2 and less in walls, ceilings 10 to 20mm thick in cement mortar 1:4 including cutting the patches in proper shape and replastering the surface of the wall including disposal of rubbish with a lead of 50m including curing cost of materials, labour, complete as per specification ---- etc., complete with all leadSqm460.64460.64112.5FalseNoneNoneFalseNoneFalse51822.00
232507268668NoneV1 Item No 2.4.1Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all leadCum7783.427783.4268.4893FalseNoneNoneFalseNoneFalse533080.9874060
232462068668NoneV1 Item No2.4.1Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all leadCum7783.427783.4293.2816FalseNoneNoneFalseNoneFalse726049.8710720
232477768668NoneV2 Item No 19.9.2Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineerin- charge. In cement mortar ---- etc., complete with all leadCum1987.121987.1275.84FalseNoneNoneFalseNoneFalse150703.18080
232477868668NoneV2 Item No 19.12.1Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking to the appropriate disposal area as per direction of Engineer-in-charge. 19.12.1 Of area 3 m² and below ---- etc., complete with all leadCum283.2283.233.84FalseNoneNoneFalseNoneFalse9583.4880
232507368668NoneV2 Item No 8.53.2Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 g/L, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. ---- etc., complete with all leadSqm120.32120.32496.0503FalseNoneNoneFalseNoneFalse59684.7720960
232462168668NoneV2 Item No8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete with all leadSqm121.54121.541788.95FalseNoneNoneFalseNoneFalse217428.9830
232477968668NoneV2 Item No 19.22.1Dismantling tile work in floors and roofs laid in cement mortar including stacking material to the appropriate disposal area as per direction of Engineer-in-charge.For thickness of tiles 10 mm to 25 mm ---- etc., complete with all leadSqm56.6456.6488.0FalseNoneNoneFalseNoneFalse4984.320
232507468668NoneV2 Item No 8.64Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :One coats on old work as per specifications and as per directions of Engineer in charge. ---- etc., complete with all leadSqm92.3792.3749.005FalseNoneNoneFalseNoneFalse4526.591850
232462268668NoneV2 Item No8.53.2Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 g/L, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. ---- etc., complete with all leadSqm120.32120.324314.1264FalseNoneNoneFalseNoneFalse519075.6884480
232507568668NoneV2 Item No 8.75.1Finishing walls with Premium Acrylic Smooth exterior paint of required shade : Old work (Two coats applied @ 1.43 l/ 10 m²) over existing cement paint surface including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm134.91134.91228.4975FalseNoneNoneFalseNoneFalse30826.5977250
232462368668NoneV2 Item No8.64Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :One coats on old work as per specifications and as per directions of Engineer in charge. ---- etc., complete with all leadSqm92.3792.37251.67FalseNoneNoneFalseNoneFalse23246.75790
232478068668NoneV3 Item No 2.5(ii)AClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer.A In area of light jungle A.In area of light jungle ---- etc., complete with all leadSqm463.74463.7416.5828FalseNoneNoneFalseNoneFalse7690.1076720
232478168668NoneV1 Item No 1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.In all kinds of soil upto 300 mm depth ---- etc., complete with all leadCum112.1112.1505.53FalseNoneNoneFalseNoneFalse56669.9130
232507668668NoneV1 Item No 2.1.3Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates ---- etc., complete with all leadCum7279.037279.0389.08FalseNoneNoneFalseNoneFalse648415.99240
232462468668NoneV2 Item No8.75.1Finishing walls with Premium Acrylic Smooth exterior paint of required shade : Old work (Two coats applied @ 1.43 l/ 10 m²) over existing cement paint surface including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm134.91134.914268.335FalseNoneNoneFalseNoneFalse575841.074850
232462568668NoneV-1 Item No2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates ---- etc., complete with all leadCum7279.037279.0376.894FalseNoneNoneFalseNoneFalse559713.732820
232507768668NoneV-2 Item No 8.3.1Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm430.25430.25488.04FalseNoneNoneFalseNoneFalse209979.210
232478268668NoneV1 Item No 1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work, In all types of soil upto 3.00 m depth ---- etc., complete with all leadCum120.36120.361107.3914FalseNoneNoneFalseNoneFalse133285.6289040
232462668668NoneV-2 Item No8.3.1Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm430.25430.25650.04FalseNoneNoneFalseNoneFalse279679.710
232478368668NoneV1 Item No 1.15.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work, In ordinary/soft rock without blasting upto 1.5 m depth ---- etc., complete with all leadCum428.34428.34109.5357FalseNoneNoneFalseNoneFalse46918.5217380
232507868668NoneV2 Item No 15.2Polyurethane based Single Component for Existing Surface Providing and Applying PU based Elastomeric Liquid Applied PU Waterproofing Membrane single component, cold applied, water based acrylic PU dispersion with highly elastic and UV resistant water proofing treatment to the Existing Roof surface/Chajjas/Sunken portion of WC: Bathroom applied @ 1.2 l/per m2, having tensile strength greater than 1.5N/mm2, elongation greater than 300% with solid content not less than 60% in 2 coats including surface preparation, priming the surface with water based acrylic primer @0.1 l/m2, and spreading 60 gsm geotextile between two top coats completely as per specification. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. ---- etc., complete with all leadSqm895.75895.75123.5068FalseNoneNoneFalseNoneFalse110631.21610
232478468668NoneV1 Item No 2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates ---- etc., complete with all leadCum7067.027067.02231.0005FalseNoneNoneFalseNoneFalse1632485.153510
232507968668NoneV2 Item No 20.103Repairing door and window frames with available wood to the required size. ---- etc., complete with all leadSqm1185.021185.0210.5FalseNoneNoneFalseNoneFalse12442.710
232462768668NoneV2 Item No15.2Polyurethane based Single Component for Existing Surface Providing and Applying PU based Elastomeric Liquid Applied PU Waterproofing Membrane single component, cold applied, water based acrylic PU dispersion with highly elastic and UV resistant water proofing treatment to the Existing Roof surface/Chajjas/Sunken portion of WC: Bathroom applied @ 1.2 l/per m2, having tensile strength greater than 1.5N/mm2, elongation greater than 300% with solid content not less than 60% in 2 coats including surface preparation, priming the surface with water based acrylic primer @0.1 l/m2, and spreading 60 gsm geotextile between two top coats completely as per specification. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. ---- etc., complete with all leadSqm895.75895.751177.7976FalseNoneNoneFalseNoneFalse1055012.20020
232508068668NoneV2 Item No 20.104Repairing and fixing shutters (panelled or glazed) to doors, windows, ventilators and cupboards. ---- etc., complete with all leadSqm1185.021185.0210.5FalseNoneNoneFalseNoneFalse12442.710
232478568668NoneV2 Item No 4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. ---- etc., complete with all leadSqm139.24139.24573.6467FalseNoneNoneFalseNoneFalse79874.5665080
232462868668NoneV2 Item No20.103Repairing door and window frames with available wood to the required size. ---- etc., complete with all leadSqm1185.021185.0270.8FalseNoneNoneFalseNoneFalse83899.4160
232478668668NoneV1 Item No 2.2.3Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Footing Concrete ---- etc., complete with all leadCum8074.68074.6115.803FalseNoneNoneFalseNoneFalse935062.90380
232508168668NoneV2 Item No 20.107Providing and fixing plain rolled glass 4mm thick with teakwood beading of 10mm thick. ---- etc., complete with all leadSqm1394.061394.061.7FalseNoneNoneFalseNoneFalse2369.9020
232462968668NoneV2 Item No20.104Repairing and fixing shutters (panelled or glazed) to doors, windows, ventilators and cupboards. ---- etc., complete with all leadSqm1185.021185.0270.8FalseNoneNoneFalseNoneFalse83899.4160
232478768668NoneV1 Item No 2.5.2Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Column Pedestal ---- etc., complete with all leadCum8224.138224.1336.7074FalseNoneNoneFalseNoneFalse301886.4295620
232508268668NoneV2 Item No 12.58Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. ---- etc., complete with all leadNos145.85145.8525.0FalseNoneNoneFalseNoneFalse3646.250
232463068668NoneV2 Item No20.107Providing and fixing plain rolled glass 4mm thick with teakwood beading of 10mm thick. ---- etc., complete with all leadSqm1394.061394.063.4FalseNoneNoneFalseNoneFalse4739.8040
232478868668NoneV1 Item No 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Columns ---- etc., complete with all leadCum13727.0613727.0640.5979FalseNoneNoneFalseNoneFalse557289.8091740
232508368668NoneV2 Item No 12.55.1Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. -do- with both side prelam ---- etc., complete with all leadSqm2875.642875.647.5FalseNoneNoneFalseNoneFalse21567.30
232463168668NoneV2 Item No12.58Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. ---- etc., complete with all leadSqm145.85145.85150.0FalseNoneNoneFalseNoneFalse21877.50
232478968668NoneV1 Item No 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Plinth Beam, Roof Slab and Stair Case ---- etc., complete with all leadCum12112.1112112.11148.6694FalseNoneNoneFalseNoneFalse1800700.1264340
232508468668NoneV2 Item No 13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter ---- etc., complete with all leadm353.68353.68158.0FalseNoneNoneFalseNoneFalse55881.440
232463268668NoneV2 Item No12.55.1Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. -do- with both side prelam ---- etc., complete with all leadSqm2875.642875.6430.0FalseNoneNoneFalseNoneFalse86269.20
232479068668NoneV1 Item No 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Lintel and Roof Beam ---- etc., complete with all leadCum12919.5812919.5847.2879FalseNoneNoneFalseNoneFalse610939.8070820
232508568668NoneV2 Item No 9.17.2Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm ---- etc., complete with all leadm1428.11428.1488.5673FalseNoneNoneFalseNoneFalse697722.961130
232463368668NoneV2 Item No11.25.2Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge. ---- etc., complete with all leadKg165.29165.29467.56FalseNoneNoneFalseNoneFalse77282.99240
232479168668NoneV1 Item No 1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete with all leadCum313.88313.88313.4398FalseNoneNoneFalseNoneFalse98382.4844240
232508668668NoneV2 Item No 9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. ---- etc., complete with all leadm1080.491080.49128.05FalseNoneNoneFalseNoneFalse138356.74450
232463468668NoneV2 Item No13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter ---- etc., complete with all leadm353.68353.68508.0FalseNoneNoneFalseNoneFalse179669.440
232479268668NoneV1 Item No 1.8Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. ---- etc., complete with all leadCum559.32559.321569.4FalseNoneNoneFalseNoneFalse877796.8080
232508768668NoneV2 Item No 9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete with all leadm1761.111761.11486.35FalseNoneNoneFalseNoneFalse856515.84850
232463568668NoneV2 Item No9.17.2Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm ---- etc., complete with all leadSqm1428.11428.1887.4832FalseNoneNoneFalseNoneFalse1267414.757920
232479368668NoneV1 Item No 2.11 aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification ---- etc., complete with all leadTonne105559.26105559.2641.8117FalseNoneNoneFalseNoneFalse4413612.1113420
232508868668NoneV2 Item No 8.2.1Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadm358.54358.54486.347FalseNoneNoneFalseNoneFalse174374.853380
232463668668NoneV2 Item No9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. ---- etc., complete with all leadSqm3466.323466.32286.3348FalseNoneNoneFalseNoneFalse992528.0439360
232479468668NoneV1 Item No 2.1.4Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all leadCum10637.2910637.2949.9776FalseNoneNoneFalseNoneFalse531626.2247040
232463768668NoneV2 Item No9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. ---- etc., complete with all leadm1080.491080.49194.76FalseNoneNoneFalseNoneFalse210436.23240
232508968668NoneV3 Item No 2.5(ii)AClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer.A In area of light jungle A.In area of light jungle ---- etc., complete with all leadSqm477.65477.655.71FalseNoneNoneFalseNoneFalse2727.38150
232509068668NoneV1 Item No 1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.In all kinds of soil upto 300 mm depth ---- etc., complete with all leadCum115.46115.46171.29FalseNoneNoneFalseNoneFalse19777.14340
232479568668NoneV2 Item No 6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete with all leadSqm1545.81545.81526.0915FalseNoneNoneFalseNoneFalse2359032.24070
232463868668NoneV2 Item No9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete with all leadm1761.111761.11611.52FalseNoneNoneFalseNoneFalse1076953.98720
232509168668NoneV1 Item No 1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work, In all types of soil upto 3.00 m depth ---- etc., complete with all leadCum123.97123.97264.06FalseNoneNoneFalseNoneFalse32735.51820
232479668668NoneV2 Item No 6.34Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete with all leadSqm1302.721302.72225.726FalseNoneNoneFalseNoneFalse294057.774720
232463968668NoneV2 Item No8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadm357.33357.33677.43FalseNoneNoneFalseNoneFalse242066.06190
232509268668NoneV1 Item No 1.15.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work, In ordinary/soft rock without blasting upto 1.5 m depth ---- etc., complete with all leadCum441.19441.1943.58FalseNoneNoneFalseNoneFalse19227.06020
232479768668NoneV2 Item No 12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- etc., complete with all leadCum116601.7116601.72.2537FalseNoneNoneFalseNoneFalse262785.251290
232464068668NoneV2 Item No12.9Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all leadSqm8184.58184.580.1FalseNoneNoneFalseNoneFalse655578.450
232509368668NoneV-3 Item No 3.1Removal of Unserviceable Soil with Disposal upto a suitable distance as directed by the Engineer incharge of work ---- etc., complete with all leadCum103.31103.3148.0FalseNoneNoneFalseNoneFalse4958.880
232479868668NoneV2 Item No 12.93.1Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Size 62 x 100mm ---- etc., complete with all leadMtr828.36828.3669.55FalseNoneNoneFalseNoneFalse57612.4380
232464168668NoneV2 Item No12.85Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all leadSqm6950.876950.8711.52FalseNoneNoneFalseNoneFalse80074.02240
232479968668NoneV2 Item No 12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- etc., complete with all leadNos1198.881198.8843.0FalseNoneNoneFalseNoneFalse51551.840
232509468668NoneV2 Item No 4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. for Plinth area ---- etc., complete with all leadCum143.42143.42115.0FalseNoneNoneFalseNoneFalse16493.30
232464268668NoneV2 Item No11.35.2.3Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-incharge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications. ---- etc., complete with all leadKg707.36707.361701.0FalseNoneNoneFalseNoneFalse1203219.360
232480068668NoneV2 Item No 11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- etc., complete with all leadKg198.24198.242491.02FalseNoneNoneFalseNoneFalse493819.80480
232509568668NoneV2 Item No 2.2.2.1Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Column Pedestal ---- etc., complete with all leadCum8252.528252.5215.82FalseNoneNoneFalseNoneFalse130554.86640
232464368668NoneV2 Item No11.36.2Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer- in-charge: Pre-laminated particle board with decorative lamination on both side including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Aluminium sections shall be smooth, rust free, straight, mitred and jointe mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-incharge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications. ---- etc., complete with all leadSqm1194.741194.7454.0FalseNoneNoneFalseNoneFalse64515.960
232509668668NoneV1 Item No 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For Lintel ---- etc., complete with all leadCum13307.1713307.1713.6025FalseNoneNoneFalseNoneFalse181010.7799250
232480168668NoneV2 Item No 11.5.1Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete with all leadSqm5284.045284.0417.7FalseNoneNoneFalseNoneFalse93527.5080
232464468668NoneV2 Item No11.37.2Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasketnetc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/m²) including cost of materials, labour, usage charges of machinery complete as per specifications. ---- etc., complete with all leadSqm1423.231423.2359.4FalseNoneNoneFalseNoneFalse84539.8620
232509768668NoneV1 Item No 1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete with all leadCum323.3323.3348.961FalseNoneNoneFalseNoneFalse112819.09130
232464568668NoneV1 Item No 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Columns ---- etc., complete with all leadCum14050.0514050.053.94FalseNoneNoneFalseNoneFalse55357.1970
232480268668NoneV2 Item No 12.57.5Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. ---- etc., complete with all leadNos4551.264551.2686.13FalseNoneNoneFalseNoneFalse392000.02380
232509868668NoneV1 Item No 1.8Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. ---- etc., complete with all leadCum576.1576.1126.41FalseNoneNoneFalseNoneFalse72824.8010
232464668668NoneV1 Item No 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Lintel Beam ---- etc., complete with all leadCum11971.1511971.1512.96FalseNoneNoneFalseNoneFalse155146.1040
232480368668NoneV2 Item No 12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer ofK value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) 30 mm thickness ---- etc., complete with all leadNos4112.34112.320.475FalseNoneNoneFalseNoneFalse84199.34250
232509968668NoneV1 Item No 2.11 aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification ---- etc., complete with all leadTonne108726.04108726.048.9792FalseNoneNoneFalseNoneFalse976272.8583680
232464768668NoneV1 Item No 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Chajja ---- etc., complete with all leadCum10876.2310876.230.86FalseNoneNoneFalseNoneFalse9353.55780
232480468668NoneV2 Item No 12.74.1Providing and fixing IS : 12817 marked stainless steel butt hinges withstainless steel screws etc. complete :125x64x1.90mm ---- etc., complete with all leadNos120.36120.36164.0FalseNoneNoneFalseNoneFalse19739.040
232510068668NoneV1 Item No 2.1.4Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all leadCum10956.4110956.416.5FalseNoneNoneFalseNoneFalse71216.6650
232464868668NoneV1 Item No 2.11 aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification ---- etc., complete with all leadTonne109781.63109781.631.6732FalseNoneNoneFalseNoneFalse183686.6233160
232480568668NoneV2 Item No 12.76.2Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :200x10mm ---- etc., complete with all leadNos413.0413.0164.0FalseNoneNoneFalseNoneFalse67732.00
232464968668NoneV1 Item No 2.1.4Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all leadCum10857.3710857.372.96FalseNoneNoneFalseNoneFalse32137.81520
232480668668NoneV2 Item No 12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete ---- etc., complete with all leadNos279.66279.6682.0FalseNoneNoneFalseNoneFalse22932.120
232510168668NoneV2 Item No 6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete with all leadSqm1592.171592.17580.56FalseNoneNoneFalseNoneFalse924350.21520
232480768668NoneV2 Item No 12.58Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. ---- etc., complete with all leadNos141.6141.682.0FalseNoneNoneFalseNoneFalse11611.20
232465068668NoneV2 Item No 6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete with all leadSqm1607.631607.630.72FalseNoneNoneFalseNoneFalse1157.49360
232510268668NoneV2 Item No 6.34Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete with all leadSqm1341.81341.828.365FalseNoneNoneFalseNoneFalse38060.1570
232510368668NoneV2 Item No 11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- etc., complete with all leadKg204.19204.19545.58FalseNoneNoneFalseNoneFalse111401.98020
232480868668NoneV2 Item No 12.9Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all leadSqm7946.127946.12103.5FalseNoneNoneFalseNoneFalse822423.420
232465168668NoneV2 Item No 8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm258.94258.9460.0FalseNoneNoneFalseNoneFalse15536.40
232510468668NoneV2 Item No 11.5.1Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete with all leadSqm5442.565442.566.3FalseNoneNoneFalseNoneFalse34288.1280
232480968668NoneV2 Item No 12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size - 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all leadSqm6748.426748.429.72FalseNoneNoneFalseNoneFalse65594.64240
232465268668NoneV2 Item No 8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge... ( Inside) ---- etc., complete with all leadSqm382.89382.89152.11FalseNoneNoneFalseNoneFalse58241.39790
232481068668NoneV2 Item No 8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm248.98248.98655.0116FalseNoneNoneFalseNoneFalse163084.7881680
232510568668NoneV2 Item No 8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge... ( Inside) ---- etc., complete with all leadSqm379.2379.2400.19FalseNoneNoneFalseNoneFalse151752.0480
232465368668NoneV2 Item No 8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete with all leadSqm122.72122.72203.11FalseNoneNoneFalseNoneFalse24925.65920
232481168668NoneV2 Item No 8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge... ( Inside) ---- etc., complete with all leadSqm368.16368.161125.2591FalseNoneNoneFalseNoneFalse414275.3902560
232465468668NoneV2 Item No 8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. ( Outside) ---- etc., complete with all leadSqm360.8360.8172.72FalseNoneNoneFalseNoneFalse62317.3760
232510668668NoneV2 Item No 8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete with all leadSqm121.54121.54527.69FalseNoneNoneFalseNoneFalse64135.44260
232510768668NoneV-2 Item No 8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. ( Outside) ---- etc., complete with all leadSqm424.17424.17170.32FalseNoneNoneFalseNoneFalse72244.63440
232481268668NoneV2 Item No 8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm346.92346.921479.9727FalseNoneNoneFalseNoneFalse513432.1290840
232465568668NoneV2 Item No 8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. ---- etc., complete with all leadm63.8163.8132.8FalseNoneNoneFalseNoneFalse2092.9680
232465668668NoneV2 Item No 8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm155.85155.85203.11FalseNoneNoneFalseNoneFalse31654.69350
232510868668NoneV2 Item No 8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm154.36154.36527.39FalseNoneNoneFalseNoneFalse81407.92040
232481368668NoneV2 Item No 8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete with all leadSqm118.0118.01762.2707FalseNoneNoneFalseNoneFalse207947.94260
232465768668NoneV2 Item No 8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm191.44191.44172.72FalseNoneNoneFalseNoneFalse33065.51680
232510968668NoneV2 Item No 8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm189.6189.6740.32FalseNoneNoneFalseNoneFalse140364.6720
232481468668NoneV2 Item No 8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. ---- etc., complete with all leadMtr61.3661.36308.0FalseNoneNoneFalseNoneFalse18898.880
232465868668NoneV2 Item No 8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm65.0465.041.89FalseNoneNoneFalseNoneFalse122.92560
232511068668NoneV2 Item No 8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm60.7760.77150.28FalseNoneNoneFalseNoneFalse9132.51560
232481568668NoneV2 Item No 9.17.2Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm ---- etc., complete with all leadSqm1386.51386.5390.4175FalseNoneNoneFalseNoneFalse541313.863750
232465968668NoneV2 Item No 8.4Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm141.13141.131.89FalseNoneNoneFalseNoneFalse266.73570
232511168668NoneV2 Item No 8.43Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade :Two coats on new work including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm114.25114.25119.7FalseNoneNoneFalseNoneFalse13675.7250
232481668668NoneV2 Item No 9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. ---- etc., complete with all leadSqm1049.021049.0229.8346FalseNoneNoneFalseNoneFalse31297.0920920
232511268668NoneV2 Item No 11.16.1Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (P.No.82, I.No. 11.16.1 of PWD SR 2023-24 Vol-2) ---- etc., complete with all leadKg165.29165.29242.56FalseNoneNoneFalseNoneFalse40092.74240
232466068668NoneV2 Item No 15.1Providing and Applying PU based Elastomeric Liquid Applied PU Waterproofing Membrane single component, cold applied, water based acrylic PU dispersion with highly elastic and UV resistant water proofing treatment to the Existing Roof surface/Chajjas/Sunken portion of WC:Bathroom applied @ 1.2L/per m2,having tensile strength greater than 1.5N/mm2, elongation greater than 300% with solid content not less than 60% in 2 coats including surface preparation, priming the surface with water based acrylic primer @0.1 L/m2, and spreading 60 gsm geotextile between two top coats completely as per specification. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. ---- etc., complete with all leadSqm1002.621002.6248.85FalseNoneNoneFalseNoneFalse48977.9870
232481768668NoneV2 Item No 9.20.2Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 600x600 mm ---- etc., complete with all leadSqm246.62246.62390.4175FalseNoneNoneFalseNoneFalse96284.763850
232511368668NoneV2 Item No 7.38Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal,complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. :(P.No.26, I.No. 7.38 of PWD SR 2023-24 Vol-2) ---- etc., complete with all leadSqm690.35690.3518.816FalseNoneNoneFalseNoneFalse12989.62560
232481868668NoneV2 Item No 9.2Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per direction of Engineer incharge. ---- etc., complete with all leadSqm944.0944.0108.0FalseNoneNoneFalseNoneFalse101952.00
232466168668NoneV3 Item No 2.5(ii)AClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer.A In area of light jungle A.In area of light jungle ---- etc., complete with all leadSqm477.65477.652.45FalseNoneNoneFalseNoneFalse1170.24250
232511468668NoneV-3 Item No 3.7Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction. ---- etc., complete with all leadCum127.62127.6248.0FalseNoneNoneFalseNoneFalse6125.760
232466268668NoneV1 Item No 1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.In all kinds of soil upto 300 mm depth ---- etc., complete with all leadCum115.46115.4660.03FalseNoneNoneFalseNoneFalse6931.06380
232481968668NoneV2 Item No 8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm149.86149.861762.2707FalseNoneNoneFalseNoneFalse264093.8871020
232511568668NoneV-3 Item No 4.2 B (V)Construction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401 .For Grading -V Material ---- etc., complete with all leadCum2867.132867.1324.0FalseNoneNoneFalseNoneFalse68811.120
232466368668NoneV1 Item No 1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work, In all types of soil upto 3.00 m depth ---- etc., complete with all leadCum123.97123.97110.32FalseNoneNoneFalseNoneFalse13676.37040
232482068668NoneV2 Item No 8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm184.08184.082090.6431FalseNoneNoneFalseNoneFalse384845.5818480
232511668668NoneV-3 Item No 4.17Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in ---- etc., complete with all leadCum3110.213110.2124.0FalseNoneNoneFalseNoneFalse74645.040
232466468668NoneV1 Item No 1.15.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work, In ordinary/soft rock without blasting upto 1.5 m depth but not exceeding 3 m ---- etc., complete with all leadCum441.19441.1912.116FalseNoneNoneFalseNoneFalse5345.458040
232482168668NoneV2 Item No 8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm59.059.0248.8999FalseNoneNoneFalseNoneFalse14685.09410
232511768668NoneV-3 Item No 8.42.3Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra) 600 x 300 x 150 mm Kerb Stone ---- etc., complete with all leadm562.73562.7380.0FalseNoneNoneFalseNoneFalse45018.40
232466568668NoneV2 Item No 4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. ---- etc., complete with all leadCum143.42143.4215.0FalseNoneNoneFalseNoneFalse2151.30
232482268668NoneV2 Item No 8.43Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade :Two coats on new work including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm110.92110.92113.2FalseNoneNoneFalseNoneFalse12556.1440
232466668668NoneV-1 Item No 2.2.3Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all leadCum8448.428448.4217.1459FalseNoneNoneFalseNoneFalse144855.7644780
232511868668NoneV-3 Item No 8.1Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces ---- etc., complete with all leadSqm132.48132.4856.0FalseNoneNoneFalseNoneFalse7418.880
232482368668NoneV2 Item No 8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm62.5462.5420.07FalseNoneNoneFalseNoneFalse1255.17780
232511968668NoneV-3 Item No 6.6Plain Cement Pavement Quality M30 grade Concrete (RMC) with OPC & GGBS laid without Paver Construction of un-reinforced plain cement concrete pavement using RMC M-30 grade with OPC @ 270 kg/m3 and GGBS@ 90kg/m3 (75:25 proportion) as per approved mix design procedure and thickness as per design, over a prepared sub base. The superplastisiser confirming to IS 9103-1999 Reaffirmed-2008, Coarse aggregates and Fine aggregate confirming to IS:383-2016, transported to site, laid in approved fixed side form work (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the form work). Spreading the concrete with shovels, rackers and compacted using needle, suitable plate vibrator and finished in a continuous operation including provision of separation membrane and Hessian cloth finishing to lines and grades complete including cost of all materials, labour, all lead & lift, loading charges as per specification & direction of Engineer - incharge of the work. (Groove cutting shall be paid seperately ---- etc., complete with all leadCum8233.128233.1224.0FalseNoneNoneFalseNoneFalse197594.880
232466768668NoneV1 Item No 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all leadCum13244.5313244.530.48FalseNoneNoneFalseNoneFalse6357.37440
232482468668NoneV2 Item No 8.4Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm135.7135.7176.8299FalseNoneNoneFalseNoneFalse23995.817430
232512068668NoneV-3 Item No 6.8.1Providing and laying 60mm thick factory made precast M -30 grade Cement Concrete Paver Block as per IRC SP 63:2018 & IS 15658 for Cycle Tracks & Pedestrian Footpaths of approved shape and colour, laid in required pattern and including over 30mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-incharge. (WMM/WBM Base to be paid separately if necessary as per relevant technical specification) ---- etc., complete with all leadSqm1298.051298.0596.0FalseNoneNoneFalseNoneFalse124612.80
232466868668NoneV1 Item No 1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete with all leadCum323.3323.38.946FalseNoneNoneFalseNoneFalse2892.24180
232482568668NoneV2 Item No 11.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete with all leadKg666.7666.727.0499FalseNoneNoneFalseNoneFalse18034.168330
232512168668NoneV-2 Item No 19.7.3Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. In cement mortar ---- etc., complete with all leadCum1250.651250.65366.6FalseNoneNoneFalseNoneFalse458488.290
232466968668NoneV1 Item No 1.8Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. ---- etc., complete with all leadCum576.1576.130.0FalseNoneNoneFalseNoneFalse17283.00
232482668668NoneV2 Item No 9.23Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : ** Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. ---- etc., complete with all leadSqm2909.882909.88212.5007FalseNoneNoneFalseNoneFalse618351.5369160
232512268668NoneV-2 Item No 19.9.2Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineerin- charge. In cement mortar ---- etc., complete with all leadCum2046.732046.73384.31FalseNoneNoneFalseNoneFalse786578.80630
232467068668NoneV1 Item No 2.11 aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification ---- etc., complete with all leadTonne108726.04108726.043.5611FalseNoneNoneFalseNoneFalse387184.3010440
232482768668NoneV2 Item No 15.1Providing and Applying PU based Elastomeric Liquid Applied PU Waterproofing Membrane single component, cold applied, water based acrylic PU dispersion with highly elastic and UV resistant water proofing treatment to the Existing Roof surface/Chajjas/Sunken portion of WC:Bathroom applied @ 1.2L/per m2,having tensile strength greater than 1.5N/mm2, elongation greater than 300% with solid content not less than 60% in 2 coats including surface preparation, priming the surface with water based acrylic primer @0.1 L/m2, and spreading 60 gsm geotextile between two top coats completely as per specification. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. Polyurethane based Single Component for New Surface ---- etc., complete with all leadSqm964.06964.06621.126FalseNoneNoneFalseNoneFalse598802.731560
232512368668NoneV-3 Item No 1.1 aLoading and Unloading of Stone Boulder/Stone aggregates/Sand/Kankar/Moorum. (Tipper 10 m3) ---- etc., complete with all leadCum164.08164.08479.84FalseNoneNoneFalseNoneFalse78732.14720
232467168668NoneV2 Item No 6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete with all leadSqm1592.171592.1742.65FalseNoneNoneFalseNoneFalse67906.05050
232482868668NoneV2 Item No 9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete with all leadSqm1709.821709.82494.8496FalseNoneNoneFalseNoneFalse846103.7430720
232512468668NoneV-1 Item No 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for COLUMNS ---- etc., complete with all leadCum14138.8714138.8714.86FalseNoneNoneFalseNoneFalse210103.60820
232482968668NoneV1 Item No 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Columns ---- etc., complete with all leadCum13807.8113807.811.64FalseNoneNoneFalseNoneFalse22644.80840
232467268668NoneV2 Item No 6.34Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete with all leadSqm1341.81341.86.0FalseNoneNoneFalseNoneFalse8050.80
232512568668NoneV-1 Item No 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Footing ---- etc., complete with all leadCum12475.4812475.4846.0141FalseNoneNoneFalseNoneFalse574047.9842680
232483068668NoneV1 Item No 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Lintel Beam and Roof Beam ---- etc., complete with all leadCum11752.1611752.163.9499FalseNoneNoneFalseNoneFalse46419.8567840
232467368668NoneV2 Item No 11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- etc., complete with all leadKg204.19204.19113.399FalseNoneNoneFalseNoneFalse23154.941810
232512668668NoneV-2 Item No 8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm450.91450.91570.0FalseNoneNoneFalseNoneFalse257018.70
232483168668NoneV1 Item No 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Chajja ---- etc., complete with all leadCum10657.2410657.240.12FalseNoneNoneFalseNoneFalse1278.86880
232467468668NoneV2 Item No 11.5.1Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete with all leadSqm5442.565442.566.3FalseNoneNoneFalseNoneFalse34288.1280
232512768668NoneV-2 Item No 11.25.2Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete with all leadKg165.29165.29777.6FalseNoneNoneFalseNoneFalse128529.5040
232483268668NoneV1 Item No 2.11 aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification ---- etc., complete with all leadTonne106614.85106614.850.5866FalseNoneNoneFalseNoneFalse62540.271010
232467568668NoneV2 Item No 8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge... ( Inside) ---- etc., complete with all leadSqm379.2379.257.35FalseNoneNoneFalseNoneFalse21747.120
232512868668NoneV-1 Item No 1.4.1Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m ---- etc., complete with all leadCum294.13294.1325.0FalseNoneNoneFalseNoneFalse7353.250
232483368668NoneV2 Item No 6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete with all leadSqm1561.261561.267.73FalseNoneNoneFalseNoneFalse12068.53980
232467668668NoneV2 Item No 8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm154.36154.3657.35FalseNoneNoneFalseNoneFalse8852.5460
232512968668NoneV-1 Item No 1.1Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour complete as per specifications ---- etc., complete with all leadCum194.46194.4625.0FalseNoneNoneFalseNoneFalse4861.50
232483468668NoneV2 Item No 8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm251.47251.4717.29FalseNoneNoneFalseNoneFalse4347.91630
232467768668NoneV2 Item No 8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm189.6189.645.35FalseNoneNoneFalseNoneFalse8598.360
232513068668NoneV-2 Item No 13.31.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 20 mm nominal dia Pipes ---- etc., complete with all leadm294.13294.1320.0FalseNoneNoneFalseNoneFalse5882.60
232467868668NoneV2 Item No 8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm60.7760.77129.7FalseNoneNoneFalseNoneFalse7881.8690
232483568668NoneV2 Item No 8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge... ( Inside) ---- etc., complete with all leadSqm371.84371.8461.39FalseNoneNoneFalseNoneFalse22827.25760
232513168668NoneV-2 Item No 13.31.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 25 mm nominal dia Pipes ---- etc., complete with all leadm386.5386.512.0FalseNoneNoneFalseNoneFalse4638.00
232467968668NoneV2 Item No 8.43Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade :Two coats on new work including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm114.25114.25119.699FalseNoneNoneFalseNoneFalse13675.610750
232483668668NoneV2 Item No 8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete with all leadSqm119.18119.1878.68FalseNoneNoneFalseNoneFalse9377.08240
232513268668NoneV-2 Item No 13.33.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 20 mm nominal dia Pipes ---- etc., complete with all leadm263.74263.7430.0FalseNoneNoneFalseNoneFalse7912.20
232468068668NoneV2 Item No 7.38Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal,complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. :(P.No.26, I.No. 7.38 of PWD SR 2023-24 Vol-2) ---- etc., complete with all leadSqm690.35690.3518.816FalseNoneNoneFalseNoneFalse12989.62560
232483768668NoneV2 Item No 8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. ( Outside) ---- etc., complete with all leadSqm350.39350.3980.2FalseNoneNoneFalseNoneFalse28101.2780
232513368668NoneV-2 Item No 13.33.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 25 mm nominal dia Pipes ---- etc., complete with all leadm359.76359.76140.0FalseNoneNoneFalseNoneFalse50366.40
232483868668NoneV2 Item No 8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. ---- etc., complete with all leadm61.9761.9730.45FalseNoneNoneFalseNoneFalse1886.98650
232468168668NoneV3 Item No 2.5(ii)AClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer.A In area of light jungle ---- etc., complete with all leadSqm477.65477.650.36FalseNoneNoneFalseNoneFalse171.9540
232468268668NoneV-1 Item No 2.2.3Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Raft ---- etc., complete with all leadCum7925.077925.074.1119FalseNoneNoneFalseNoneFalse32587.0953330
232513468668NoneV-2 Item No 13.63Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0 cm X 4.0 cm with all fitting arrangements & all necessary accessories complete ---- etc., complete with all leadEach296.56296.5660.0FalseNoneNoneFalseNoneFalse17793.60
232483968668NoneV2 Item No 8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm151.36151.3678.68FalseNoneNoneFalseNoneFalse11909.00480
232468368668NoneV-1 Item No 2.2.3Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates TOP SLAB ---- etc., complete with all leadCum9196.079196.073.0839FalseNoneNoneFalseNoneFalse28359.7602730
232513568668NoneV-2 Item No 13.64.1Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75mm nominal dia pipes ---- etc., complete with all leadm351.25351.2520.0FalseNoneNoneFalseNoneFalse7025.00
232484068668NoneV2 Item No 8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm185.92185.9280.2FalseNoneNoneFalseNoneFalse14910.7840
232513668668NoneV-2 Item No 13.64.2Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 110mm nominal dia pipes ---- etc., complete with all leadm30.3930.3920.0FalseNoneNoneFalseNoneFalse607.80
232468468668NoneV-2 Item No 15.1Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/ Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. ---- etc., complete with all leadSqm992.98992.98101.56FalseNoneNoneFalseNoneFalse100847.04880
232484168668NoneV2 Item No 8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm63.1763.171.89FalseNoneNoneFalseNoneFalse119.39130
232513768668NoneV-2 Item No 13.64.3Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 150mm nominal dia pipes ---- etc., complete with all leadm933.43933.4350.0FalseNoneNoneFalseNoneFalse46671.50
232468568668NoneV-2 Item No 8.4Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm139.77139.7741.12FalseNoneNoneFalseNoneFalse5747.34240
232484268668NoneV2 Item No 8.4Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm137.06137.061.89FalseNoneNoneFalseNoneFalse259.04340
232468668668None18-19 SR Item No XXIV (624)C. I Manhole covers 24" x 24" ---- etc., complete with all leadNos2575.02575.06.0FalseNoneNoneFalseNoneFalse15450.00
232513868668NoneV-2 Item No 13.59Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete ---- etc., complete with all leadEach267.39267.3910.0FalseNoneNoneFalseNoneFalse2673.90
232484368668NoneV2 Item No 15.1Providing and Applying PU based Elastomeric Liquid Applied PU Waterproofing Membrane single component, cold applied, water based acrylic PU dispersion with highly elastic and UV resistant water proofing treatment to the Existing Roof surface/Chajjas/Sunken portion of WC:Bathroom applied @ 1.2L/per m2,having tensile strength greater than 1.5N/mm2, elongation greater than 300% with solid content not less than 60% in 2 coats including surface preparation, priming the surface with water based acrylic primer @0.1 L/m2, and spreading 60 gsm geotextile between two top coats completely as per specification. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. ---- etc., complete with all leadSqm973.7973.783.14FalseNoneNoneFalseNoneFalse80953.4180
232513968668NoneV-2 Item No 13.22.1.1Providing and fixing PTMT grating of approved quality and colour. Circular type 100 mm nominal dia ---- etc., complete with all leadNos49.8349.8310.0FalseNoneNoneFalseNoneFalse498.30
232468768668NoneV-5 Item No 12.4Geophysical investigation of site for sinking Borewell for supplying drinking water to Habitation either through the Handpump, MWS or PWSS by vertical sounding by adopting veener sounding by adopting veener or schlumbergers's including reconassiance of survey of Geological formation,geophysical investigation of existing ground water in the vicinity quality, quantity and acceptability of the user including the location of site,recommended department of casing pipe required to seal the top and consolidated formation including an extra depth of 1.00Mtr in consolidated formation including an extra depth of drilling required to cover full depth of occupier proposed to trap probable yield and other information required including transportation of instrument and accessories to work site engaging technical personnel labour required etc complete as directed by Engineer in charge ---- etc., complete with all leadEach6427.046427.041.0FalseNoneNoneFalseNoneFalse6427.040
232484468668NoneV1 Item No 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all leadCum13000.7713000.770.48FalseNoneNoneFalseNoneFalse6240.36960
232514068668NoneV-2 Item No 13.5.2Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 20 mm nominal bore ---- etc., complete with all leadNos381.64381.6420.0FalseNoneNoneFalseNoneFalse7632.80
232468868668NoneV-5 Item No 12.1Sinking of borewell of 165 mm dia clear using super fast hydraulic of capasity 300 PSIG & above 1100 CMF & above in all strata including over burden upto 20 M fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle crew charges and cost of consumables, etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes) for piped water supply schemes Upto 50 Mtrs ---- etc., complete with all leadRmtr449.7449.750.0FalseNoneNoneFalseNoneFalse22485.00
232484568668NoneV2 Item No 11.16.1Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (P.No.82, I.No. 11.16.1 of PWD SR 2023-24 Vol-2) ---- etc., complete with all leadKg160.48160.48976.956FalseNoneNoneFalseNoneFalse156781.898880
232514168668NoneV-2 Item No 13.3.2Providing and fixing brass stop cock of approved quality 20 mm nominal bore ---- etc., complete with all leadNos370.7370.720.0FalseNoneNoneFalseNoneFalse7414.00
232468968668NoneV-5 Item No 12.1Sinking of borewell of 165 mm dia clear using super fast hydraulic of capasity 300 PSIG & above 1100 CMF & above in all strata including over burden upto 20 M fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle crew charges and cost of consumables, etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes) for piped water supply schemes Above 50 Mtrs and upto 100 Mtr. ---- etc., complete with all leadRmtr563.95563.9550.0FalseNoneNoneFalseNoneFalse28197.50
232484668668NoneV2 Item No 7.38Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal,complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. :(P.No.26, I.No. 7.38 of PWD SR 2023-24 Vol-2) ---- etc., complete with all leadSqm670.24670.2418.816FalseNoneNoneFalseNoneFalse12611.235840
232484768668NoneV-1 Item No 2.2.3Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all leadCum7700.777700.778.648FalseNoneNoneFalseNoneFalse66596.258960
232514268668NoneV-2 Item No 13.4.1Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore ---- etc., complete with all leadNos667.25667.2520.0FalseNoneNoneFalseNoneFalse13345.00
232469068668NoneV-5 Item No 12.1Sinking of borewell of 165 mm dia clear using super fast hydraulic of capasity 300 PSIG & above 1100 CMF & above in all strata including over burden upto 20 M fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle crew charges and cost of consumables, etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes) for piped water supply schemes Above100 Mtrs. and upto 150 Mtr. ---- etc., complete with all leadRmtr599.19599.1950.0FalseNoneNoneFalseNoneFalse29959.50
232484868668NoneV-1 Item No 2.2.3Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates forTOP SLAB ---- etc., complete with all leadCum8971.788971.7810.59FalseNoneNoneFalseNoneFalse95011.15020
232514368668NoneV-2 Item No 13.2.2Providing and fixing brass bib cock of approved quality : 20 mm nominal bore ---- etc., complete with all leadNos370.7370.720.0FalseNoneNoneFalseNoneFalse7414.00
232469168668NoneV-5 Item No 12.1Sinking of borewell of 165 mm dia clear using super fast hydraulic of capasity 300 PSIG & above 1100 CMF & above in all strata including over burden upto 20 M fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle crew charges and cost of consumables, etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes) for piped water supply schemes Above150 Mtrs. and upto 200 Mtr. ---- etc., complete with all leadRmtr695.21695.2150.0FalseNoneNoneFalseNoneFalse34760.50
232514468668NoneV-2 Item No 13.53Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 2 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5 ---- etc., complete with all leadNos6857.296857.295.0FalseNoneNoneFalseNoneFalse34286.450
232484968668NoneV-2 Item No 15.1Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/ Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. ---- etc., complete with all leadSqm964.06964.06206.6FalseNoneNoneFalseNoneFalse199174.7960
232469268668NoneV-5 Item No 12.1Sinking of borewell of 165 mm dia clear using super fast hydraulic of capasity 300 PSIG & above 1100 CMF & above in all strata including over burden upto 20 M fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle crew charges and cost of consumables, etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes) for piped water supply schemes Above200 Mtrs. and upto 250 Mtr. ---- etc., complete with all leadRmtr815.53815.5350.0FalseNoneNoneFalseNoneFalse40776.50
232514568668NoneV-2 Item No 13.53Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 2 kg (weight of cover 23 kg and weight of frame 15 kg) With common burnt clay (non modular) bricks of class designation 3.5 ---- etc., complete with all leadNos12841.9212841.925.0FalseNoneNoneFalseNoneFalse64209.60
232485068668NoneV-2 Item No 8.3.1Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm417.72417.72234.4FalseNoneNoneFalseNoneFalse97913.5680
232469368668NoneV-5 Item No 12.1Sinking of borewell of 165 mm dia clear using super fast hydraulic of capasity 300 PSIG & above 1100 CMF & above in all strata including over burden upto 20 M fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle crew charges and cost of consumables, etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes) for piped water supply schemes Above250 Mtrs. and upto 300 Mtr. ---- etc., complete with all leadRmtr899.4899.435.0FalseNoneNoneFalseNoneFalse31479.00
232485168668None18-19 SR Item No XXIV (624)C. I Manhole covers 24" x 24" and with frame 610 * 455mm size (38kgs) ---- etc., complete with all leadNos2500.02500.014.0FalseNoneNoneFalseNoneFalse35000.00
232514668668NoneV-2 Item No 14.28.2.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40mm dia pipes, From wash basin waste lines ---- etc., complete with all leadEach111.82111.8253.5FalseNoneNoneFalseNoneFalse5982.370
232469468668NoneV-5 Item No 12.32Supply Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. ---- etc., complete with all leadRmtr2349.372349.3725.0FalseNoneNoneFalseNoneFalse58734.250
232485268668NoneV-1 Item No 1.14.2Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth 3 to 6m ---- etc., complete with all leadCum138.06138.062.496FalseNoneNoneFalseNoneFalse344.597760
232514768668NoneV-2 Item No 14.32.3Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Oval shape 450x350 mm (outer dimensions) ---- etc., complete with all leadEach1295.621295.6210.0FalseNoneNoneFalseNoneFalse12956.20
232469568668NoneV-5 Item No 13.28Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments ---- etc., complete with all leadRmtr668.47668.47200.0FalseNoneNoneFalseNoneFalse133694.00
232485368668NoneV-1 Item No 1.15.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work Depth exceeding 1.5 m, but not exceeding 3 m ---- etc., complete with all leadCum533.36533.369.984FalseNoneNoneFalseNoneFalse5325.066240
232514868668NoneV-2 Item No 14.40.2600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. ---- etc., complete with all leadEach602.84602.8414.0FalseNoneNoneFalseNoneFalse8439.760
232469668668NoneV-5 Item No 12.33Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments ---- etc., complete with all leadNos182.31182.311.0FalseNoneNoneFalseNoneFalse182.310
232485468668NoneV-1 Item No 1.15.3Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work Depth exceeding 1.5 m, but not exceeding 3 m ---- etc., complete with all leadCum546.34546.341.9968FalseNoneNoneFalseNoneFalse1090.9317120
232514968668NoneV-2 Item No 14.2.1Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid ---- etc., complete with all leadEach585.82585.828.0FalseNoneNoneFalseNoneFalse4686.560
232469768668NoneV-5 Item No 12.34Providing and laying at site of work MS casing caps as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge ---- etc., complete with all leadNos199.33199.331.0FalseNoneNoneFalseNoneFalse199.330
232469868668NoneLeast Quotation RateProviding NP/CP 50mm dia Waste Unions conforming to ISI specifications and fixing them in position as per directions (Rates includes cost of materials fixtures and conveyance to work spot etc complete) ---- etc., complete with all leadNos247.8247.81.0FalseNoneNoneFalseNoneFalse247.80
232485568668NoneV-1 Item No 1.16.1Earth work excavation for FOUNDATION by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work In Hard Rock ( requiring blasting) Depth upto 1.50m ---- etc., complete with all leadCum653.72653.722.496FalseNoneNoneFalseNoneFalse1631.685120
232515068668NoneV-2 Item No 20.44.2Providing & fixing White vitreous china water closet squatting pan (Indian type) along with "S" or "P" trap including dismantling of old WC seat and "S" or "P" trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge. Orissa pattern W.C Pan of size 580x440 mm ---- etc., complete with all leadEach4311.024311.026.0FalseNoneNoneFalseNoneFalse25866.120
232485668668NoneV-1 Item No 1.16.2Earth work excavation for FOUNDATION by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work In Hard Rock ( requiring blasting) Depth exceeding 1.5 m, but not exceeding 3 m ---- etc., complete with all leadCum735.14735.142.496FalseNoneNoneFalseNoneFalse1834.909440
232515168668NoneV-2 Item No 14.7.7White Vitreous China Flat back wash basin size 450x 300 mm with single 15mm C.P. brass pillar tap ---- etc., complete with all leadEach2551.122551.125.0FalseNoneNoneFalseNoneFalse12755.60
232469968668NoneV-5 Item No 13.13.6Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 5.00 HP - 90 LPM @ 110 m = 10 STG Outlet Dia - 2.00" ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete with all leadEach39059.3139059.311.0FalseNoneNoneFalseNoneFalse39059.310
232485768668NoneV-1 Item No 1.16.3Earth work excavation for FOUNDATION by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work In Hard Rock ( requiring blasting) Depth exceeding 1.5 m, but not exceeding 3 m ---- etc., complete with all leadCum838.98838.980.4992FalseNoneNoneFalseNoneFalse418.8188160
232470068668NoneV-5 Item No 13.23.2Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter Up to 3 to 6 HP ---- etc., complete with all lead& lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete with all leadEach11269.011269.01.0FalseNoneNoneFalseNoneFalse11269.00
232515268668NoneV6 Item No 1.8.2Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends,junction box,elbows,screws at an interval of 300 mm as required. 25mm ---- etc., complete with all leadm42.5442.5440.0FalseNoneNoneFalseNoneFalse1701.60
232485868668NoneV-3 Item No 1.1 aLoading and Unloading of Stone Boulder/Stone aggregates/Sand/Kankar/Moorum. (Tipper 10 m3) ---- etc., complete with all leadCum159.3159.370.6748FalseNoneNoneFalseNoneFalse11258.495640
232470168668NoneV-5 Item No 13.29Supply and delivery at site 50mm(2”) dia heavy duty CI adopter set complete suitable for uPVC Column pipes for Submersible pumpsets. complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete with all leadSet1883.871883.871.0FalseNoneNoneFalseNoneFalse1883.870
232515368668NoneV6 Item No 1.9.2SupplyingPVCflexibleconduitpipe....mmdiafixingonsurfaceoverinvertedtaperedwoodenplugsorphillplugsorrawlplugsandclampedusingheavygaugesaddlesatanintervalof300mmusigNFscrews and on either end of the pipe terminated completely 25mm ---- etc., complete with all leadm26.7426.7410.0FalseNoneNoneFalseNoneFalse267.40
232470268668NoneV-5 Item No 13.31Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets. ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete with all leadJob48.6248.62100.0FalseNoneNoneFalseNoneFalse4862.00
232485968668NoneV1 Item No 2.5.2Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Beam ---- etc., complete with all leadCum11214.7211214.721.9872FalseNoneNoneFalseNoneFalse22285.8915840
232515468668NoneV6 Item No 2.2.1SupplyingandwiringadoptingloopsysteminexistingPVCConduit/casingcappingcasingcappingusing2x1.5Sqmm(Phase&Neutral)&1x1.0sqmm(Earthwire)FRLSmultistrandPVCinsulatedcopperwire(confirmingtoIS-694:andlatestamendments)without controlswitchshallbefixedontheexistingplasticsheet/gangbox,theotherendofthewiresshallbeterminatedwithsufficientlooselength in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch box ---- etc., complete with all leadPoint326.94326.948.0FalseNoneNoneFalseNoneFalse2615.520
232470368668NoneV-5 Item No 13.32Labour charges for Erection, Electrification and commissioning works of Pump sets including aligning and balancing with all necessary erection of materials and labour including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges, tools and equipments etc., involved in the job. as per specifications, with testing of as per instructions of engineer incharge of work ---- etc., complete with all lead& lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete with all leadJob7900.17900.11.0FalseNoneNoneFalseNoneFalse7900.10
232486068668NoneV1 Item No 2.5.2Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for lintel-beam ---- etc., complete with all leadCum11962.3711962.370.576FalseNoneNoneFalseNoneFalse6890.325120
232515568668NoneV6 Item No 2.2.2SupplyingandwiringadoptingloopsysteminexistingPVCConduit/casingcappingcasingcappingusing2x1.5Sqmm(Phase&Neutral)&1x1.0sqmm(Earthwire)FRLSmultistrandPVCinsulatedcopperwire(confirmingtoIS-694:andlatestamendments)without controlswitchshallbefixedontheexistingplasticsheet/gangbox,theotherendofthewiresshallbeterminatedwithsufficientlooselength in a wood/PVC round block. complete for each outlet. Mediumpointabove3Mtrupto6Mtrfromtappingpointtooutletviaswitch box ---- etc., complete with all leadPoint460.64460.648.0FalseNoneNoneFalseNoneFalse3685.120
232486168668NoneLeast Quotation RateSteel Windows with grill for residential buildings Providing and fixing of windows made of pre-painted steel (base steel as per IS 513 of0.58mm tick galvanized as per IS 277 with zinc of 120 GSM). Primer coated with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with 5-7microns thick alkyd backer. Section for outer frame should be of 48x50mm, centre mullion should be of 48x50mm, section for shutter should be of 48x25mm and fixed glass beading section should be of 12x12mm. Outer frame and mullions to have rebate for glazed shutter and a 20mm provision for guard bars/grills. The sections are to be cut to length mitre joined with corner bracket. Centre mullion is to be fixed with mullion cap. Handle stay 2Nos of stainless steel heavy duty pivot hinges shall be provided for shutter. The window should be panelled with 5mm thick plain fioat glass. Rubber gaskets are to be provided all around the glass. The above frames should be fixed to the concrete/ masonry wall by means of self expanding screws, including 10mm square guard bars with 6" (152.4mm) pitch etc., complete for finished item of work. ---- etc., complete with all leadSqm4434.444434.442.25FalseNoneNoneFalseNoneFalse9977.490
232470468668NoneV-5 Item No 13.33Labour charges for Erection of outdoor type panel board and meter board units with all necessary materials and labour tools and equipments including providing cement concrete foundation bed etc., complete. as per specifications, with testing of as per instructions of engineer incharge of work ---- etc., complete with all lead& lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete with all leadJob1640.791640.791.0FalseNoneNoneFalseNoneFalse1640.790
232515668668NoneV6 Item No 2.2.3SupplyingandwiringadoptingloopsysteminexistingPVCConduit/casingcappingcasingcappingusing2x1.5Sqmm(Phase&Neutral)&1x1.0sqmm(Earthwire)FRLSmultistrandPVCinsulatedcopperwire(confirmingtoIS-694:andlatestamendments)without controlswitchshallbefixedontheexistingplasticsheet/gangbox,theotherendofthewiresshallbeterminatedwithsufficientlooselength in a wood/PVC round block. complete for each outlet. Longpointabove6Mtrupto10Mtrfromtappingpointtooutletviaswitch box ---- etc., complete with all leadPoint674.55674.558.0FalseNoneNoneFalseNoneFalse5396.40
232486268668NoneV-2 Item No 8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. . (outside) ---- etc., complete with all leadSqm437.78437.781187.32FalseNoneNoneFalseNoneFalse519784.94960
232470568668NoneV-6 Item No 2.6.2Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirmining to table 3 class 5 of IS:8130-1984 and virgin grade PVC insulation and sheathed suitable for working voltage upto 1100Volts as per IS-694:1990 & confirming to GTP of GROUP-A(12/2.10) 3C x 6 mm ---- etc., complete with all leadRmtr204.19204.19259.0FalseNoneNoneFalseNoneFalse52885.210
232515768668NoneV6 Item No 2.3.1Wiringforlighting/powercircuitusingoneofFRLSPVCinsulated1100Vgrade,multistrandcopperwirewithlowconductorresistancesinglecoreinopenorconcealedsystemofwiringwithspecifiedIS-694:2010 1 mm2 ---- etc., complete with all leadm23.0923.09300.0FalseNoneNoneFalseNoneFalse6927.00
232486368668NoneV-5 Item No 12.4Geophysical investigation of site for sinking Borewell for supplying drinking water to Habitation either through the Handpump, MWS or PWSS by vertical sounding by adopting veener sounding by adopting veener or schlumbergers's including reconassiance of survey of Geological formation,geophysical investigation of existing ground water in the vicinity quality, quantity and acceptability of the user including the location of site,recommended department of casing pipe required to seal the top and consolidated formation including an extra depth of 1.00Mtr in consolidated formation including an extra depth of drilling required to cover full depth of occupier proposed to trap probable yield and other information required including transportation of instrument and accessories to work site engaging technical personnel labour required etc complete as directed by Engineer in charge ---- etc., complete with all leadEach6239.846239.841.0FalseNoneNoneFalseNoneFalse6239.840
232470668668NoneV-6 Item No 5.42.2Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG ---- etc., complete with all leadSq CM0.520.5230000.0FalseNoneNoneFalseNoneFalse15600.00
232515868668NoneV6 Item No 2.3.3Wiringforlighting/powercircuitusingoneofFRLSPVCinsulated1100Vgrade,multistrandcopperwirewithlowconductorresistancesinglecoreinopenorconcealedsystemofwiringwithspecifiedIS-694:2010- 2.5 mm2 ---- etc., complete with all leadm51.0551.05200.0FalseNoneNoneFalseNoneFalse10210.00
232486468668NoneV-5 Item No 12.1Sinking of borewell of 165 mm dia clear using super fast hydraulic of capasity 300 PSIG & above 1100 CMF & above in all strata including over burden upto 20 M fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle crew charges and cost of consumables, etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes) for piped water supply schemes Upto 50 Mtrs ---- etc., complete with all leadRmtr436.6436.650.0FalseNoneNoneFalseNoneFalse21830.00
232470768668NoneV-6 Item No 5.44.4Supply and Installation I Fixing I Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase I Three Phase Energy Meter in suitable base plate and having a provision for Fuse I MCB cutout with suitable transparent hinged flap opening for operating MCB along with 10 complete tamper proof SEALING facility. (50/6.42) 600mmx600mmx170mm. ---- etc., complete with all leadEach17647.6117647.611.0FalseNoneNoneFalseNoneFalse17647.610
232515968668NoneV6 Item No 2.3.4Wiringforlighting/powercircuitusingoneofFRLSPVCinsulated1100Vgrade,multistrandcopperwirewithlowconductorresistancesinglecoreinopenorconcealedsystemofwiringwithspecifiedIS-694:2010- 4 mm2 ---- etc., complete with all leadm76.5776.57200.0FalseNoneNoneFalseNoneFalse15314.00
232486568668NoneV-5 Item No 12.1Sinking of borewell of 165 mm dia clear using super fast hydraulic of capasity 300 PSIG & above 1100 CMF & above in all strata including over burden upto 20 M fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle crew charges and cost of consumables, etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes) for piped water supply schemes Above 50 Mtrs and upto 100 Mtr. ---- etc., complete with all leadRmtr547.52547.5250.0FalseNoneNoneFalseNoneFalse27376.00
232470868668NoneV-6 Item No 5.6.6Supplying and fixing polished wood board made of not less than 15mm thick plank on both sides with planks made out of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws etc. - 500 x 500 x 65 mm (20" x 20" x 2.5") etc., complete as per directions of the Engineer-in-charge ---- etc., complete with all leadEach396.38396.381.0FalseNoneNoneFalseNoneFalse396.380
232516068668NoneV6 Item No 2.3.5Wiringforlighting/powercircuitusingoneofFRLSPVCinsulated1100Vgrade,multistrandcopperwirewithlowconductorresistancesinglecoreinopenorconcealedsystemofwiringwithspecifiedIS-694:2010- 6 mm2 ---- etc., complete with all leadm111.82111.8220.0FalseNoneNoneFalseNoneFalse2236.40
232470968668NoneLeast Quotation Rate.Supplying and fixing miniature circuit breakers/Isolators on existing MCB distribution boards using necessary fixing materials and wiring complete as directed by the Engineer-in-charge - 5 to 30 Amps Triple and Neutral ---- etc., complete with all leadEach2023.72023.71.0FalseNoneNoneFalseNoneFalse2023.70
232486668668NoneV-5 Item No 12.1Sinking of borewell of 165 mm dia clear using super fast hydraulic of capasity 300 PSIG & above 1100 CMF & above in all strata including over burden upto 20 M fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle crew charges and cost of consumables, etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes) for piped water supply schemes Above100 Mtrs. and upto 150 Mtr. ---- etc., complete with all leadRmtr581.74581.7450.0FalseNoneNoneFalseNoneFalse29087.00
232516168668NoneV6 Item No 3.14.1Supplying And fixing/replacing of 6/16/32A electricalaccessories on existing switch board. 6A SP Switch ---- etc., complete with all leadNos66.8566.8520.0FalseNoneNoneFalseNoneFalse1337.00
232471068668NoneLeast Quotation Rate.Supplying and fixing TPST with neutral link switches rewirable fuse type - Havels / Standard / Indo-Asian Crescent - 30 to 35 Amps, etc., complete as per directions of the Engineer-in-charge ---- etc., complete with all leadEach2124.02124.01.0FalseNoneNoneFalseNoneFalse2124.00
232486768668NoneV-5 Item No 12.1Sinking of borewell of 165 mm dia clear using super fast hydraulic of capasity 300 PSIG & above 1100 CMF & above in all strata including over burden upto 20 M fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle crew charges and cost of consumables, etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes) for piped water supply schemes Above150 Mtrs. and upto 200 Mtr. ---- etc., complete with all leadRmtr674.96674.9650.0FalseNoneNoneFalseNoneFalse33748.00
232516268668NoneV6 Item No 3.14.1Supplying And fixing/replacing of 6/16/32A electricalaccessories on existing switch board. 6A Two Way Switch ---- etc., complete with all leadNos85.0885.082.0FalseNoneNoneFalseNoneFalse170.160
232471168668NoneLeast Quotation Rate.Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery (48/6.35) ---- etc., complete with all leadEach472.0472.01.0FalseNoneNoneFalseNoneFalse472.00
232486868668NoneV-5 Item No 12.1Sinking of borewell of 165 mm dia clear using super fast hydraulic of capasity 300 PSIG & above 1100 CMF & above in all strata including over burden upto 20 M fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle crew charges and cost of consumables, etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes) for piped water supply schemes Above200 Mtrs. and upto 250 Mtr. ---- etc., complete with all leadRmtr791.78791.7850.0FalseNoneNoneFalseNoneFalse39589.00
232516368668NoneV6 Item No 3.14.2Supplying And fixing/replacing of 6/16/32A electricalaccessories on existing switch board. 6A Three Way 5 Pin Socket ---- etc., complete with all leadNos85.0885.084.0FalseNoneNoneFalseNoneFalse340.320
232471268668NoneV-3 Item No 3.1Removal of Unserviceable Soil with Disposal upto a suitable distance as directed by the Engineer incharge of work ---- etc., complete with all leadCum103.31103.3163.0FalseNoneNoneFalseNoneFalse6508.530
232486968668NoneV-5 Item No 12.1Sinking of borewell of 165 mm dia clear using super fast hydraulic of capasity 300 PSIG & above 1100 CMF & above in all strata including over burden upto 20 M fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle crew charges and cost of consumables, etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes) for piped water supply schemes Above250 Mtrs. and upto 300 Mtr. ---- etc., complete with all leadRmtr873.2873.235.0FalseNoneNoneFalseNoneFalse30562.00
232516468668NoneV6 Item No 3.14.7Supplying And fixing/replacing of 6/16/32A electricalaccessories on existing switch board. 6A Batten Holder ---- etc., complete with all leadNos89.9489.948.0FalseNoneNoneFalseNoneFalse719.520
232471368668NoneV-3 Item No 6.6Plain Cement Pavement Quality M30 grade Concrete (RMC) with OPC & GGBS laid without Paver Construction of un-reinforced plain cement concrete pavement using RMC M-30 grade with OPC @ 270 kg/m3 and GGBS@ 90kg/m3 (75:25 proportion) as per approved mix design procedure and thickness as per design, over a prepared sub base. The superplastisiser confirming to IS 9103-1999 Reaffirmed-2008, Coarse aggregates and Fine aggregate confirming to IS:383-2016, transported to site, laid in approved fixed side form work (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the form work). Spreading the concrete with shovels, rackers and compacted using needle, suitable plate vibrator and finished in a continuous operation including provision of separation membrane and Hessian cloth finishing to lines and grades complete including cost of all materials, labour, all lead & lift, loading charges as per specification & direction of Engineer - incharge of the work. (Groove cutting shall be paid seperately ---- etc., complete with all leadCum8233.128233.124.725FalseNoneNoneFalseNoneFalse38901.4920
232487068668NoneV-5 Item No 12.32Supply Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. ---- etc., complete with all leadRmtr2280.942280.9425.0FalseNoneNoneFalseNoneFalse57023.50
232516568668NoneV6 Item No 3.14.10Supplying And fixing/replacing of 6/16/32A electricalaccessories on existing switch board. 16A SP Switch ---- etc., complete with all leadNos159.22159.222.0FalseNoneNoneFalseNoneFalse318.440
232471468668NoneV-3 Item No 6.8.1Providing and laying 60mm thick factory made precast M -30 grade Cement Concrete Paver Block as per IRC SP 63:2018 & IS 15658 for Cycle Tracks & Pedestrian Footpaths of approved shape and colour, laid in required pattern and including over 30mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-incharge. (WMM/WBM Base to be paid separately if necessary as per relevant technical specification) ---- etc., complete with all leadSqm1298.051298.05210.0FalseNoneNoneFalseNoneFalse272590.50
232487168668NoneV-5 Item No 13.28Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments ---- etc., complete with all leadRmtr649.0649.0200.0FalseNoneNoneFalseNoneFalse129800.00
232516668668NoneV6 Item No 3.14.12Supplying And fixing/replacing of 6/16/32A electricalaccessories on existing switch board. 16A Three Way 5 Pin Socket ---- etc., complete with all leadNos139.77139.772.0FalseNoneNoneFalseNoneFalse279.540
232471568668NoneV-1 Item No 1.4.1Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m ---- etc., complete with all leadCum294.13294.13190.0FalseNoneNoneFalseNoneFalse55884.70
232487268668NoneV-5 Item No 12.33Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments ---- etc., complete with all leadNos177.0177.01.0FalseNoneNoneFalseNoneFalse177.00
232516768668NoneV6 Item No 3.14.14Supplying And fixing/replacing of 6/16/32A electricalaccessories on existing switch board. 32A Bakelite DP ---- etc., complete with all leadNos281.97281.974.0FalseNoneNoneFalseNoneFalse1127.880
232471668668NoneV-1 Item No 1.1Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour complete as per specifications ---- etc., complete with all leadCum194.46194.46190.0FalseNoneNoneFalseNoneFalse36947.40
232487368668NoneV-5 Item No 12.34Providing and laying at site of work MS casing caps as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge ---- etc., complete with all leadNos193.52193.521.0FalseNoneNoneFalseNoneFalse193.520
232516868668NoneV6 Item No 3.14.16Supplying And fixing/replacing of 6/16/32A electricalaccessories on existing switch board. Electronic stepped regulator. ---- etc., complete with all leadNos341.53341.536.0FalseNoneNoneFalseNoneFalse2049.180
232487468668NoneLeast Quotation RateProviding NP/CP 50mm dia Waste Unions conforming to ISI specifications and fixing them in position as per directions (Rates includes cost of materials fixtures and conveyance to work spot etc complete) ---- etc., complete with all leadNos247.8247.81.0FalseNoneNoneFalseNoneFalse247.80
232471768668NoneV-2 Item No 13.31.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 20 mm nominal dia Pipes ---- etc., complete with all leadm294.13294.13380.0FalseNoneNoneFalseNoneFalse111769.40
232516968668NoneV6 Item No 3.12.2Supplying......wayplasticgangboxandfixingusingnecessarywooden/ rawl/phill plugs and screws. 2 to 4 Way Gang Box ---- etc., complete with all leadNos38.8938.898.0FalseNoneNoneFalseNoneFalse311.120
232471868668NoneV-2 Item No 13.31.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 25 mm nominal dia Pipes ---- etc., complete with all leadm386.5386.5228.0FalseNoneNoneFalseNoneFalse88122.00
232487568668NoneV-5 Item No 13.13.6Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 5.00 HP - 90 LPM @ 110 m = 10 STG Outlet Dia - 2.00" ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete with all leadEach37921.6637921.661.0FalseNoneNoneFalseNoneFalse37921.660
232517068668NoneV6 Item No 3.9Supplyingandfixinghylumplasticsheet3mmthickwithnecessarynitchesforfixingswitches,regulatorsetc.,andfixingonexistingwood or metal box using N. F. screws. ---- etc., complete with all leadSqm0.420.424500.0FalseNoneNoneFalseNoneFalse1890.00
232471968668NoneV-2 Item No 13.33.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 20 mm nominal dia Pipes ---- etc., complete with all leadm263.74263.74570.0FalseNoneNoneFalseNoneFalse150331.80
232487668668NoneV-5 Item No 13.23.2Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter Up to 3 to 6 HP ---- etc., complete with all lead& lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete with all leadEach11269.011269.01.0FalseNoneNoneFalseNoneFalse11269.00
232517168668NoneV6 Item No 3.10.2Supplying4mmthickwhiteplasticplateandcoveringforjunctionboxesofsize......mmconduitusingnecessarymachinescrews. 80/90 mm ---- etc., complete with all leadNos18.2318.232.0FalseNoneNoneFalseNoneFalse36.460
232472068668NoneV-2 Item No 13.33.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 25 mm nominal dia Pipes ---- etc., complete with all leadm359.76359.76760.0FalseNoneNoneFalseNoneFalse273417.60
232487768668NoneV-5 Item No 13.29Supply and delivery at site 50mm(2”) dia heavy duty CI adopter set complete suitable for uPVC Column pipes for Submersible pumpsets. complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete with all leadSet1829.01829.01.0FalseNoneNoneFalseNoneFalse1829.00
232517268668NoneV6 Item No 4.3Supplyanderectionof14FeetHeightStreetLightPole14FeetHeightStreetLightPoleonsuitablecementconcretefoundationwith2.5Feetheightdia5mmcastirondecorativeroundpedestalasperdesignweighingnotlessthan37Kgs,thepedestalshallbefittedwithClass'C'G.I.Pipe7Feetheight75mmouterdiaand7feetheighttoppieceouterdiaof65mmfixedbymeasureofthreading/welding/couplingcomplete. (excluding foundation). ---- etc., complete with all leadNos25037.2425037.245.0FalseNoneNoneFalseNoneFalse125186.20
232472168668NoneV-2 Item No 13.63Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0 cm X 4.0 cm with all fitting arrangements & all necessary accessories complete ---- etc., complete with all leadEach296.56296.5660.0FalseNoneNoneFalseNoneFalse17793.60
232487868668NoneV-5 Item No 13.31Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets. ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete with all leadJob47.247.2100.0FalseNoneNoneFalseNoneFalse4720.00
232517368668NoneV6 Item No 6.1Supplyingexhaustfanof1440RPMof300mm(12")sizewithbracketbladescompleteforlightdutysuitabletooperateon230V50Hz, AC Supply. ---- etc., complete with all leadEach1813.381813.382.0FalseNoneNoneFalseNoneFalse3626.760
232472268668NoneV-2 Item No 13.64.1Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75mm nominal dia pipes ---- etc., complete with all leadm351.25351.25380.0FalseNoneNoneFalseNoneFalse133475.00
232487968668NoneV-5 Item No 13.32Labour charges for Erection, Electrification and commissioning works of Pump sets including aligning and balancing with all necessary erection of materials and labour including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges, tools and equipments etc., involved in the job. as per specifications, with testing of as per instructions of engineer incharge of work ---- etc., complete with all lead& lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete with all leadJob7670.07670.01.0FalseNoneNoneFalseNoneFalse7670.00
232517468668NoneV6 Item No 6.3.1Supplyingcapacitortypeceilingfancompletewithdownrodblades,shackle,canopiesetc,foroperationon230V,50cycles.SinglephaseACsupplyconformingtoISS-374-1979andwithdoubleballbearingsystem. 48" Sweep (1200 mm) Regular model ---- etc., complete with all leadEach3626.753626.754.0FalseNoneNoneFalseNoneFalse14507.00
232472368668NoneV-2 Item No 13.64.2Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 110mm nominal dia pipes ---- etc., complete with all leadm467.93467.93380.0FalseNoneNoneFalseNoneFalse177813.40
232488068668NoneV-5 Item No 13.33Labour charges for Erection of outdoor type panel board and meter board units with all necessary materials and labour tools and equipments including providing cement concrete foundation bed etc., complete. as per specifications, with testing of as per instructions of engineer incharge of work ---- etc., complete with all lead& lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete with all leadJob1593.01593.01.0FalseNoneNoneFalseNoneFalse1593.00
232517568668NoneV6 Item No 11.3.1Supplyingof.....feet-PVCBattenwithintegratedLEDtube....WwithhighqualitydiffuserwithLifeof25000burninghours&70%lumenmaintenancewithCRI more than 80.PowerInput:220-240V@50/60Hz&Powerfactor more than 0.9alongwithCEapproved.2yearsWarrantyagainstanymanufacturingdefectworkingunderstandardelectrical condition. LED light fitting 1 x 2' - 9/10 W ---- etc., complete with all leadEach669.69669.694.0FalseNoneNoneFalseNoneFalse2678.760
232472468668NoneV-2 Item No 13.64.3Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 150mm nominal dia pipes ---- etc., complete with all leadm933.43933.43380.0FalseNoneNoneFalseNoneFalse354703.40
232488168668NoneV-6 Item No 2.6.2Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirmining to table 3 class 5 of IS:8130-1984 and virgin grade PVC insulation and sheathed suitable for working voltage upto 1100Volts as per IS-694:1990 & confirming to GTP of GROUP-A(12/2.10) 3C x 6 mm ---- etc., complete with all leadRmtr198.24198.24259.0FalseNoneNoneFalseNoneFalse51344.160
232517668668NoneV6 Item No 11.3.3Supplyingof.....feet-PVCBattenwithintegratedLEDtube....WwithhighqualitydiffuserwithLifeof25000burninghours&70%lumenmaintenancewithCRI more than 80.PowerInput:220-240V@50/60Hz&Powerfactor more than 0.9alongwithCEapproved.2yearsWarrantyagainstanymanufacturingdefectworkingunderstandardelectrical condition. LED light fitting 1 x 4' - 36/40 W ---- etc., complete with all leadEach1542.341542.346.0FalseNoneNoneFalseNoneFalse9254.040
232472568668NoneV-2 Item No 13.59Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete ---- etc., complete with all leadEach267.39267.3960.0FalseNoneNoneFalseNoneFalse16043.40
232488268668NoneV-6 Item No 5.42.2Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG ---- etc., complete with all leadSq CM0.510.5130000.0FalseNoneNoneFalseNoneFalse15300.00
232517768668NoneV6 Item No 12.41Supplying&Fixingof250W/400WHighPressureSodiumVapourtubularLampwithXenonfilledgaswithluminousefficiencyofgreaterthan140lumen/Worinitiallumensofgreaterthan55000lumens&avgratedlifegreaterthan26000hrs.&minimumstartingtemperatureof(-)40degC&Hotrestriketime less than 60SecwithCCT2000K.Operatingvoltagerangefrom180Vto265V,50HzACpowerSupply ---- etc., complete with all leadEach2156.122156.125.0FalseNoneNoneFalseNoneFalse10780.60
232472668668NoneV-2 Item No 13.22.1.1Providing and fixing PTMT grating of approved quality and colour. Circular type 100 mm nominal dia ---- etc., complete with all leadNos49.8349.8360.0FalseNoneNoneFalseNoneFalse2989.80
232488368668NoneV-6 Item No 5.44.4Supply and Installation I Fixing I Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase I Three Phase Energy Meter in suitable base plate and having a provision for Fuse I MCB cutout with suitable transparent hinged flap opening for operating MCB along with 10 complete tamper proof SEALING facility. (50/6.42) 600mmx600mmx170mm. ---- etc., complete with all leadEach17133.617133.61.0FalseNoneNoneFalseNoneFalse17133.60
232517868668NoneV6 Item No 11.15SupplyingandfixingofLEDBulkheadof10WwithIP65protectionandIK08impactresistancesuitableforsurfaceandwallmountingapplications. ---- etc., complete with all leadEach1023.371023.372.0FalseNoneNoneFalseNoneFalse2046.740
232472768668NoneV-2 Item No 13.5.2Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 20 mm nominal bore ---- etc., complete with all leadNos381.64381.6420.0FalseNoneNoneFalseNoneFalse7632.80
232488468668NoneV-6 Item No 5.6.6Supplying and fixing polished wood board made of not less than 15mm thick plank on both sides with planks made out of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws etc. - 500 x 500 x 65 mm (20" x 20" x 2.5") etc., complete as per directions of the Engineer-in-charge ---- etc., complete with all leadEach384.83384.831.0FalseNoneNoneFalseNoneFalse384.830
232517968668NoneV6 Item No 12.56Supplying,fixing,wiring,earthelectrodeforgroundingconduits,I.C.cutoutsandotherequipment'sonthemeterboardusing40mmdia2.90mmthickGIpipe2.5mlongburiedinapit.Thepitshouldbefilledwithequalproportionofsaltandcharcoal150mmall-roundthepipetocompletedepth.Theconnectionfromthepipetotheconduitetc.,istobeestablishedthroughGIwireofsizeasperlSIspecification7.3.3.ofIS732using12mmdiabolts,nuts,washersandchecknutsetc., the pipe shall have 16 through holes of 12 mm dia ---- etc., complete with all leadNos4266.054266.051.0FalseNoneNoneFalseNoneFalse4266.050
232488568668NoneLeast Quotation Rate.Supplying and fixing miniature circuit breakers/Isolators on existing MCB distribution boards using necessary fixing materials and wiring complete as directed by the Engineer-in-charge - 5 to 30 Amps Triple and Neutral ---- etc., complete with all leadEach2023.72023.71.0FalseNoneNoneFalseNoneFalse2023.70
232472868668NoneV-2 Item No 13.3.2 Providing and fixing brass stop cock of approved quality 20 mm nominal bore ---- etc., complete with all leadNos370.7370.740.0FalseNoneNoneFalseNoneFalse14828.00
232518068668NoneV6 Item No 13.1.2SupplyingandFixingof........mmdiaclassAGIpipebracketupto2mslongbentatsuitableangleandfixingtothisbracketstreetlightfittingofallcapacitiestoGIorGIorrailorRCpole/wallusingsuitableclamps,bolts,andnutsandwiringusingsuitablecapacitywires. Using 32mm dia G.I.Pipe ---- etc., complete with all leadEach1270.091270.095.0FalseNoneNoneFalseNoneFalse6350.450
232488668668NoneLeast Quotation Rate.Supplying and fixing TPST with neutral link switches rewirable fuse type - Havels / Standard / Indo-Asian Crescent - 30 to 35 Amps, etc., complete as per directions of the Engineer-in-charge ---- etc., complete with all leadEach2124.02124.01.0FalseNoneNoneFalseNoneFalse2124.00
232472968668NoneV-2 Item No 13.4.1Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore ---- etc., complete with all leadNos667.25667.2540.0FalseNoneNoneFalseNoneFalse26690.00
232518168668NoneV6 Item No 13.5Fixinghalogen/metalhalide/SVL/IL/LEDfloodlightfittingoverexistingpole/wallceilingincludingclamps,bolts,nutsandwiringusing suitable capacity wires. ---- etc., complete with all leadEach196.89196.895.0FalseNoneNoneFalseNoneFalse984.450
232488768668NoneLeast Quotation Rate.Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery (48/6.35) ---- etc., complete with all leadEach472.0472.01.0FalseNoneNoneFalseNoneFalse472.00
232473068668NoneV-2 Item No 13.2.2Providing and fixing brass bib cock of approved quality : 20 mm nominal bore ---- etc., complete with all leadNos370.7370.760.0FalseNoneNoneFalseNoneFalse22242.00
232518268668NoneV6 Item No 13.7.1Fixingalltypesandallcapacitiesoffluorescent/falseceiling/spotlight/CFL/LEDfittingsindooronthewall/ceiling/rafters/girdersusing23/0.0076"twintwistedPVCinsulatedwires,requiredNosofround blocks and clamps. On wall/ ceiling / Rafter / Girders ---- etc., complete with all leadEach148.28148.2850.0FalseNoneNoneFalseNoneFalse7414.00
232473168668NoneV-2 Item No 13.53Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5 ---- etc., complete with all leadNos6857.296857.2950.0FalseNoneNoneFalseNoneFalse342864.50
232488868668NoneV-3 Item No 3.1Removal of Unserviceable Soil with Disposal upto a suitable distance as directed by the Engineer incharge of work ---- etc., complete with all leadCum100.3100.39.0FalseNoneNoneFalseNoneFalse902.70
232518368668NoneV6 Item No 13.1Fixingaceiling/Wallmountingfanofallcapacitiesandalltypestotheexisting'S''hookwithfanregulatortotheexistingboardtogetherwithsupplyingandfixing5A.ceilingrose,necessarylengthof23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. ---- etc., complete with all leadEach207.83207.8310.0FalseNoneNoneFalseNoneFalse2078.30
232473268668NoneV-2 Item No 13.53Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) With common burnt clay (non modular) bricks of class designation 3.5 ---- etc., complete with all leadNos12841.9212841.9210.0FalseNoneNoneFalseNoneFalse128419.20
232488968668NoneV-3 Item No 3.7Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction. ---- etc., complete with all leadCum123.9123.927.0FalseNoneNoneFalseNoneFalse3345.30
232518468668NoneV6 Item No 13.14Fixing one exhaust faninthenitch already left in the wall with bolts and nuts and 5A.ceiling rose withsufficient lengthof23/0.0076 inch PVC insulated twin core wire. ---- etc., complete with all leadEach597.98597.982.0FalseNoneNoneFalseNoneFalse1195.960
232473368668NoneV-2 Item No 13.53.1Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) With common burnt clay (non modular) bricks of class designation 3.5 Extra for depth for manholes : Size 90x80 cm With common burnt clay (non modular) bricks of class designation ---- etc., complete with all leadNos11225.4311225.435.0FalseNoneNoneFalseNoneFalse56127.150
232489068668NoneV-3 Item No 4.2 B (V)Construction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401 .For Grading -V Material ---- etc., complete with all leadCum2783.622783.6213.5FalseNoneNoneFalseNoneFalse37578.870
232518568668NoneV2 Item No 19.3Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. ---- etc., complete with all leadCum2948.562948.5674.37FalseNoneNoneFalseNoneFalse219284.40720
232473468668NoneV-2 Item No 14.28.2.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40mm dia pipes, From wash basin waste lines ---- etc., complete with all leadEach111.82111.8221.0FalseNoneNoneFalseNoneFalse2348.220
232489168668NoneV-3 Item No 4.17Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in ---- etc., complete with all leadCum3019.623019.6213.5FalseNoneNoneFalseNoneFalse40764.870
232518668668NoneV2 Item No 19.12.1Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking to the appropriate disposal area as per direction of Engineer-in-charge. 19.12.1 Of area 3 m² and below ---- etc., complete with all leadCum291.7291.7135.36FalseNoneNoneFalseNoneFalse39484.5120
232473568668NoneV-2 Item No 14.32.3Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Oval shape 450x350 mm (outer dimensions) ---- etc., complete with all leadEach1295.621295.6220.0FalseNoneNoneFalseNoneFalse25912.40
232489268668NoneV-3 Item No 8.42.3Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra) 600 x 300 x 150 mm Kerb Stone ---- etc., complete with all leadm546.34546.3430.0FalseNoneNoneFalseNoneFalse16390.20
232518768668NoneV2 Item No 19.22.1Dismantling tile work in floors and roofs laid in cement mortar including stacking material to the appropriate disposal area as per direction of Engineer-in-charge.For thickness of tiles 10 mm to 25 mm ---- etc., complete with all leadSqm58.3458.34352.0FalseNoneNoneFalseNoneFalse20535.680
232518868668NoneV-1 Item No 1.15.2Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work Depth exceeding 1.5 m, but not exceeding 3 m ---- etc., complete with all leadCum516.55516.5518.564FalseNoneNoneFalseNoneFalse9589.23420
232473668668NoneV-2 Item No 14.40.2600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. ---- etc., complete with all leadEach602.84602.8420.0FalseNoneNoneFalseNoneFalse12056.80
232489368668NoneV-3 Item No 8.1Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces ---- etc., complete with all leadSqm128.62128.6221.0FalseNoneNoneFalseNoneFalse2701.020
232518968668NoneV-1 Item No 2.2.2.1Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for PEDESTALS ---- etc., complete with all leadCum8405.348405.341.764FalseNoneNoneFalseNoneFalse14827.019760
232473768668NoneV-2 Item No 14.2.1Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid ---- etc., complete with all leadEach5880.115880.1112.0FalseNoneNoneFalseNoneFalse70561.320
232489468668NoneV-3 Item No 6.6Plain Cement Pavement Quality M30 grade Concrete (RMC) with OPC & GGBS laid without Paver Construction of un-reinforced plain cement concrete pavement using RMC M-30 grade with OPC @ 270 kg/m3 and GGBS@ 90kg/m3 (75:25 proportion) as per approved mix design procedure and thickness as per design, over a prepared sub base. The superplastisiser confirming to IS 9103-1999 Reaffirmed-2008, Coarse aggregates and Fine aggregate confirming to IS:383-2016, transported to site, laid in approved fixed side form work (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the form work). Spreading the concrete with shovels, rackers and compacted using needle, suitable plate vibrator and finished in a continuous operation including provision of separation membrane and Hessian cloth finishing to lines and grades complete including cost of all materials, labour, all lead & lift, loading charges as per specification & direction of Engineer - incharge of the work. (Groove cutting shall be paid seperately ---- etc., complete with all leadCum7993.327993.3213.5FalseNoneNoneFalseNoneFalse107909.820
232473868668NoneV-2 Item No 20.44.2Providing & fixing White vitreous china water closet squatting pan (Indian type) along with "S" or "P" trap including dismantling of old WC seat and "S" or "P" trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge. Orissa pattern W.C Pan of size 580x440 mm ---- etc., complete with all leadEach4311.024311.025.0FalseNoneNoneFalseNoneFalse21555.10
232519068668NoneV-3 Item No 17.4Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical Specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/Epoxy ---- etc., complete with all leadNos247.94247.9415.0FalseNoneNoneFalseNoneFalse3719.10
232489568668NoneV-3 Item No 6.8.1Providing and laying 60mm thick factory made precast M -30 grade Cement Concrete Paver Block as per IRC SP 63:2018 & IS 15658 for Cycle Tracks & Pedestrian Footpaths of approved shape and colour, laid in required pattern and including over 30mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-incharge. (WMM/WBM Base to be paid separately if necessary as per relevant technical specification) ---- etc., complete with all leadSqm1260.241260.2460.0FalseNoneNoneFalseNoneFalse75614.40
232489668668NoneV-1 Item No 2.1.4Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all leadCum7336.067336.066.0FalseNoneNoneFalseNoneFalse44016.360
232473968668NoneV-2 Item No 14.10.1.3Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040 mm bowl depth 200 mm ---- etc., complete with all leadEach6002.866002.865.0FalseNoneNoneFalseNoneFalse30014.30
232519168668NoneV-2 Item No 8.83KSRB 4-5 :Providing Lath plaster with cement mortar 1:3 5cm thick with 6mm dia mild steel bars at 20cms. C to c both horizontally and vertically fixing chicken mesh for drop chejjas, facia, backing to cup board including cost of all materials, labour, providing and removing form work HOM of machineries, curing, complete as per specification. ---- etc., complete with all leadSqm1504.671504.676.633FalseNoneNoneFalseNoneFalse9980.476110
232489768668NoneV-1 Item No 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for COLUMNS ---- etc., complete with all leadCum8029.438029.439.45FalseNoneNoneFalseNoneFalse75878.11350
232474068668NoneV-2 Item No 14.7.7White Vitreous China Flat back wash basin size 450x 300 mm with single 15mm C.P. brass pillar tap ---- etc., complete with all leadEach2551.122551.1210.0FalseNoneNoneFalseNoneFalse25511.20
232519268668NoneV-2 Item No 5.4Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) ---- etc., complete with all leadCum7765.197765.191.26FalseNoneNoneFalseNoneFalse9784.13940
232519368668None15 Item No 4.21KSRB 4-2.12 : Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. Specification No . KBS ---- etc., complete with all leadRmtr38.9438.9460.0FalseNoneNoneFalseNoneFalse2336.40
232489868668NoneV-1 Item No 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Footing ---- etc., complete with all leadCum7518.467518.465.4FalseNoneNoneFalseNoneFalse40599.6840
232474168668NoneV-2 Item No 13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank. ---- etc., complete with all leadLtr10.9410.946000.0FalseNoneNoneFalseNoneFalse65640.00
232519468668NoneItem No 23Providing throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas & parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge. ---- etc., complete with all leadRmtr86.1486.1460.0FalseNoneNoneFalseNoneFalse5168.40
232489968668NoneV-1 Item No 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Plinth Beam ---- etc., complete with all leadCum8759.388759.3818.0FalseNoneNoneFalseNoneFalse157668.840
232474268668NoneV6 Item No 1.8.2Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends,junction box,elbows,screws at an interval of 300 mm as required. 25mm ---- etc., complete with all leadm42.5442.54240.0FalseNoneNoneFalseNoneFalse10209.60
232519568668NoneV-2 Item No 12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- etc., complete with all leadCum120099.75120099.750.3023FalseNoneNoneFalseNoneFalse36306.1544250
232490068668NoneV-2 Item No 14.28.2.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40mm dia pipes, From wash basin waste lines ---- etc., complete with all leadm108.56108.5610.0FalseNoneNoneFalseNoneFalse1085.60
232474368668NoneV6 Item No 1.9.2Supplying PVC flexible conduit pipe....mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddle satan interval of 300mm usig NF screws and on either end of the pipe terminated completely 25mm ---- etc., complete with all leadm26.7426.7460.0FalseNoneNoneFalseNoneFalse1604.40
232519668668NoneV-2 Item No 12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- etc., complete with all leadNos1234.851234.856.0FalseNoneNoneFalseNoneFalse7409.10
232490168668NoneV-5 Item No 16.7.4Providing and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make including trench excavation and refilling etc. for EXTERNAL WORKS with: ---- etc., complete with all leadm164.02164.0250.0FalseNoneNoneFalseNoneFalse8201.00
232474468668NoneV6 Item No 2.2.1Supplying and wiring adopting loop system in existing PVC Conduit/casing capping casing capping using 2x1.5Sqmm (Phase&Neutral) & 1x1.0sqmm (Earth wire) FRLS multistrand PVC insulated copper wire(confirming to IS-694 and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch box ---- etc., complete with all leadPoint326.94326.9448.0FalseNoneNoneFalseNoneFalse15693.120
232519768668NoneV-2 Item No 12.60Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. ---- etc., complete with all leadNos1011.211011.216.0FalseNoneNoneFalseNoneFalse6067.260
232490268668NoneV-5 Item No 657PVC pipe - OD 75mm and 6 Kg/sqcm, waste lines, (Shaft Drainage) ---- etc., complete with all leadm145.14145.1485.0FalseNoneNoneFalseNoneFalse12336.90
232474568668NoneV6 Item No 2.2.2Supplying and wiring adopting loop system in existing PVC Conduit/casing capping casing capping using 2x1.5Sqmm (Phase&Neutral) & 1x1.0sqmm (Earth wire) FRLS multistrand PVC insulated copper wire (confirming to IS-694 and latest amendments) without control switch shall be fixed on the existing plastic sheet/gangbox, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3 Mtr upto 6Mtr from tapping point to outlet via switch box ---- etc., complete with all leadPoint460.64460.6448.0FalseNoneNoneFalseNoneFalse22110.720
232519868668NoneV-2 Item No 12.61Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete. ---- etc., complete with all leadNos754.76754.766.0FalseNoneNoneFalseNoneFalse4528.560
232490368668NoneV-5 Item No 647PVC pipe - OD 110mm and 6 Kg/sqcm, sanitary lines, (Shaft Drainage) ---- etc., complete with all leadm300.9300.9250.0FalseNoneNoneFalseNoneFalse75225.00
232474668668NoneV6 Item No 2.2.3Supplying and wiring adopting loop system in existing PVC Conduit/casing capping casing capping using 2x1.5Sqmm (Phase&Neutral) & 1x1.0sqmm (Earth wire) FRLS multistrand PVC insulated copper wire (confirming to IS-694 and latest amendments) without control switch shall be fixed on the existing plastic sheet/gangbox, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr upto 10Mtr from tapping point to outlet via switch box ---- etc., complete with all leadPoint674.55674.5548.0FalseNoneNoneFalseNoneFalse32378.40
232519968668NoneV-2 Item No 12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete ---- etc., complete with all leadNos212.7212.712.0FalseNoneNoneFalseNoneFalse2552.40
232490468668NoneV-2 Item No 13.47Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 75mm diameter ---- etc., complete with all leadm232.46232.46100.0FalseNoneNoneFalseNoneFalse23246.00
232474768668NoneV6 Item No 2.3.1Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multi strand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 1 mm2 ---- etc., complete with all leadm23.0923.091800.0FalseNoneNoneFalseNoneFalse41562.00
232520068668NoneV-2 Item No 12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete ---- etc., complete with all leadNos134.91134.9112.0FalseNoneNoneFalseNoneFalse1618.920
232490568668NoneV-2 Item No 13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter ---- etc., complete with all leadm343.38343.3850.0FalseNoneNoneFalseNoneFalse17169.00
232474868668NoneV6 Item No 2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multi strand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 2.5 mm2 ---- etc., complete with all leadm51.0551.051200.0FalseNoneNoneFalseNoneFalse61260.00
232490668668NoneApproved Rate Providing, fixing, testing and commissioning of deep seal PVC multi inlet floor trap of self cleansing design moulded or fabricated with CP grating, rubber ring / solvent cement followed by application of leak proof adhesive like FRP paste including making good the floors etc., complete as directed by the Engineer in charge & approved quality confirming to ISI or BIS Standards (Market Rate) ---- etc., complete with all leadNos371.7371.720.0FalseNoneNoneFalseNoneFalse7434.00
232520168668NoneV-2 Item No 12.64Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms ---- etc., complete with all leadNos57.1257.126.0FalseNoneNoneFalseNoneFalse342.720
232474968668NoneV6 Item No 2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multi strand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 4 mm2 ---- etc., complete with all leadm76.5776.57600.0FalseNoneNoneFalseNoneFalse45942.00
232490768668NoneSR 2018-19 Item No 37.28.1Drilling holes of 2.50 cms dia (roof/chajja/stone). in slabs upto 7.50 cms thick ---- etc., complete with all leadNos154.58154.5830.0FalseNoneNoneFalseNoneFalse4637.40
232520268668NoneV-2 Item No 12.75.1Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type) ---- etc., complete with all leadNos244.3244.318.0FalseNoneNoneFalseNoneFalse4397.40
232475068668NoneV6 Item No 2.3.5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multi strand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 6 mm2 ---- etc., complete with all leadm111.82111.82120.0FalseNoneNoneFalseNoneFalse13418.40
232490868668NoneSR 2018-19 Item No 37.28.2Drilling holes of 2.50 cms dia (roof/chajja/stone). in slabs upto 10 cms thick ---- etc., complete with all leadNos185.26185.2630.0FalseNoneNoneFalseNoneFalse5557.80
232520368668NoneV-2 Item No 10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm ---- etc., complete with all leadNos72.9272.9236.0FalseNoneNoneFalseNoneFalse2625.120
232475168668NoneV6 Item No 3.14.1Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. 6A SP Switch ---- etc., complete with all leadNos66.8566.85120.0FalseNoneNoneFalseNoneFalse8022.00
232490968668NoneV-2 Item No 14.32.2Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm ---- etc., complete with all leadEach1201.241201.245.0FalseNoneNoneFalseNoneFalse6006.20
232475268668NoneV6 Item No 3.14.2Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. 6A Two Way Switch ---- etc., complete with all leadNos85.0885.0812.0FalseNoneNoneFalseNoneFalse1020.960
232520468668NoneXI Item No 309 (0115)Providing & Fixing of corner beads of wooden door frame to wall including cost of materials, labour charges, complete as per specifications. ---- etc., complete with all leadRmtr15.015.031.2FalseNoneNoneFalseNoneFalse468.00
232520568668NoneV-2 Item No 12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial ---- etc., complete with all leadSqm4037.564037.5612.6FalseNoneNoneFalseNoneFalse50873.2560
232491068668NoneV-2 Item No 13.9.2Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter ---- etc., complete with all leadNos329.22329.225.0FalseNoneNoneFalseNoneFalse1646.10
232475368668NoneV6 Item No 3.14.3Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. 6A Three Way 5 Pin Socket ---- etc., complete with all leadNos85.0885.0824.0FalseNoneNoneFalseNoneFalse2041.920
232520668668NoneV-2 Item No 12.9Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all leadSqm8184.58184.518.42FalseNoneNoneFalseNoneFalse150758.490
232491168668NoneV-2 Item No 14.22BProviding and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. ---- etc., complete with all leadNos6563.166563.164.0FalseNoneNoneFalseNoneFalse26252.640
232475468668NoneV6 Item No 3.14.7Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. 6A Batten Holder ---- etc., complete with all leadNos89.9489.9448.0FalseNoneNoneFalseNoneFalse4317.120
232520768668NoneV-2 Item No 12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size - 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all leadSqm6950.876950.872.16FalseNoneNoneFalseNoneFalse15013.87920
232491268668NoneV-2 Item No 14.40.2600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. ---- etc., complete with all leadNos585.28585.286.0FalseNoneNoneFalseNoneFalse3511.680
232475568668NoneV6 Item No 3.14.10Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. 16A SP Switch ---- etc., complete with all leadNos159.22159.2212.0FalseNoneNoneFalseNoneFalse1910.640
232520868668NoneV-2 Item No 12.98Providing & fixing fiber glass reinforced plastic (FRP) Door frame of cross section 90mm x 45mm having single rebate of 32mm x 15mm to recieve shutter of 30mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyster resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The fram,e shall be covered with fiber glass form all sides. MS stay shall be provided at the bottom to steady the frame. ---- etc., complete with all leadm781.5781.519.8FalseNoneNoneFalseNoneFalse15473.70
232491368668NoneV-2 Item No 14.3.1Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous chinaflushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mmflush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete,including painting of fittings and brackets, cutting and making goodthe walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid ---- etc., complete with all leadNos7052.867052.863.0FalseNoneNoneFalseNoneFalse21158.580
232475668668NoneV6 Item No 3.14.12Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. 16A Three Way 5 Pin Socket ---- etc., complete with all leadNos139.77139.7712.0FalseNoneNoneFalseNoneFalse1677.240
232520968668NoneV-2 Item No 12.99.1Providing & fixing to existing door frames, 30mm thick Glass fibre reinforced plastic (FRP) panelled door shutter of required colour and approved brand and manufacture made with fire retardant grade unsaturated polyster resin, moulded to 3mm thick FRP Laminate for forming hollow railsand styles with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings cast monolithically with 5mm thick FRP Laminate for panels conforming to IS 14856 Including fixing to frames ---- etc., complete with all leadSqm3894.143894.146.3FalseNoneNoneFalseNoneFalse24533.0820
232491468668NoneV-2 Item No 14.4.1Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: ---- etc., complete with all leadNos5763.125763.123.0FalseNoneNoneFalseNoneFalse17289.360
232475768668NoneV6 Item No 3.14.14Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. 32A Bakelite DP ---- etc., complete with all leadNos281.97281.9724.0FalseNoneNoneFalseNoneFalse6767.280
232521068668None118 Item No 8.16.3Providing and fixing plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per Sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment ) ---- etc., complete with all leadRmtr51.9251.92209.0FalseNoneNoneFalseNoneFalse10851.280
232491568668NoneApproved Rate Supplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ). (Market Rate) ---- etc., complete with all leadNos2183.02183.03.0FalseNoneNoneFalseNoneFalse6549.00
232475868668NoneV6 Item No 3.14.16Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. Electronic stepped regulator. ---- etc., complete with all leadNos341.53341.5336.0FalseNoneNoneFalseNoneFalse12295.080
232491668668NoneV-2 Item No 14.1.1Providing & fixing White vitreous china water closet squatting pan (Indian type) along with "S" or "P" trap including dismantling of old WC seat and "S" or "P" trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge. Orissa pattern W.C Pan of size 580x440 mm ---- etc., complete with all leadEach5763.125763.123.0FalseNoneNoneFalseNoneFalse17289.360
232521168668NoneV-2 Item No 8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm256.45256.45127.0386FalseNoneNoneFalseNoneFalse32579.048970
232475968668NoneV6 Item No 3.12.2Supplying......way plastic gang box and fixing using necessary wooden/ rawl/phill plugs and screws. 2 to 4 Way Gang Box ---- etc., complete with all leadNos38.8938.8948.0FalseNoneNoneFalseNoneFalse1866.720
232491768668NoneV-2 Item No 14.4.3Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : Range of three urinal basins with 10litre white P.V.C. automatic flushing cistern ---- etc., complete with all leadNos11156.911156.94.0FalseNoneNoneFalseNoneFalse44627.60
232521268668NoneV-2 Item No 15.1Providing and Applying PU based Elastomeric Liquid Applied PU Waterproofing Membrane single component, cold applied, water based acrylic PU dispersion with highly elastic and UV resistant water proofing treatment to the Existing Roof surface/Chajjas/Sunken portion of WC:Bathroom applied @ 1.2L/per m2,having tensile strength greater than 1.5N/mm2, elongation greater than 300% with solid content not less than 60% in 2 coats including surface preparation, priming the surface with water based acrylic primer @0.1 L/m2, and spreading 60 gsm geotextile between two top coats completely as per specification. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. Polyurethane based Single Component for New Surface ---- etc., complete with all leadCum992.98992.9818.279FalseNoneNoneFalseNoneFalse18150.681420
232476068668NoneV6 Item No 3.9Supplying and fixing hylum plastic sheet 3 mm thick with necessary nitches for fixing switches, regulators etc., and fixing on existing wood or metal box using N. F. screws. ---- etc., complete with all leadSq CM0.430.4327000.0FalseNoneNoneFalseNoneFalse11610.00
232521368668None70 Item No 10.5.2Bore Packing : Filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulaion on the bore. Including all labour charges tools and equipments, all complete as per the manufacturer. ---- etc., complete with all leadSqm283.2283.215.0FalseNoneNoneFalseNoneFalse4248.00
232491868668NoneV-2 Item No 14.11.2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm ---- etc., complete with all leadNos5996.765996.764.0FalseNoneNoneFalseNoneFalse23987.040
232476168668NoneV6 Item No 3.10.2Supplying 4 mm thick white plastic plate and covering for junction boxes of size......mm conduit using necessary machine screws. 80/90 mm ---- etc., complete with all leadNos18.2318.2354168.0FalseNoneNoneFalseNoneFalse987482.640
232491968668NoneApproved Rate Supplying, fixing, testing and commissioning of Sink Cock with Swinging Casted Spout (Wall Mounted Model): CON-CHR-347KN for pantry sink with CP wall flange etc. Standard make confirming to ISI standards,Model as per attached photo catalogue and as per instruction of engineer incharge. ( Jaguar make or Equalent ) (Market Place) ---- etc., complete with all leadNos1146.961146.961.0FalseNoneNoneFalseNoneFalse1146.960
232521468668NoneV-2 Item No 8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. ---- etc., complete with all leadRmtr63.263.2224.8FalseNoneNoneFalseNoneFalse14207.360
232476268668NoneV6 Item No 4.3Supply and erection of 14 Feet Height Street Light Pole 14 Feet Height Street Light Pole on suitable cement concrete foundation with 2.5 Feet height dia 5mm cast iron decorative round pedestal as per design weighing not less than 37Kgs, the pedestal shall be fitted with Class 'C' G.I.Pipe 7 Feet height 75mm outer dia and 7feet height top piece outer dia of 65mm fixed by measure of threading/welding/coupling complete. (excluding foundation). ---- etc., complete with all leadNos25037.2425037.2410.0FalseNoneNoneFalseNoneFalse250372.40
232492068668NoneApprove Rate Providing and fixing in position Exposed Part Kit of Concealed Stop Cock with Fitting Sleeve, Operating Lever & Adjustable Wall Flange (Compatible with ALD-087FT) ( Jaguar make or Equalent ) including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. (Market Place) ---- etc., complete with all leadNos1024.911024.912.0FalseNoneNoneFalseNoneFalse2049.820
232521568668NoneV-2 Item No 9.23Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : ** Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. ---- etc., complete with all leadSqm2997.182997.1818.4875FalseNoneNoneFalseNoneFalse55410.365250
232476368668NoneV6 Item No 6.1Supplying exhaust fan of 1440 RPM of 300mm (12inches) size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. ---- etc., complete with all leadEach1813.381813.3812.0FalseNoneNoneFalseNoneFalse21760.560
232521668668NoneV-2 Item No 11.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete with all leadKg686.7686.780.4FalseNoneNoneFalseNoneFalse55210.680
232492168668NoneV-2 Item No 14.7.1Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps ---- etc., complete with all leadNos3636.763636.768.0FalseNoneNoneFalseNoneFalse29094.080
232476468668NoneV6 Item No 6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc,for operation on 230V, 50cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48inches Sweep (1200 mm) Regular model ---- etc., complete with all leadEach3626.753626.7524.0FalseNoneNoneFalseNoneFalse87042.00
232492268668NoneApproved Rate Supplying and fixing PCC Pedestal 450 x 250 x 200mm with MS sloted angle iron brackets, supports with necessary drilling holes to suit the insertion of pipe clamps deburning etc., as per detailed drawing for supporting water supply pipes with suitable MS clamps, bolts, anchor bolts, nuts and washers fixed on shaft walls / outer walls etc. The quoted rate shall include with the cost of brackets galvanizing with zinc alloy of 0.08mm thick conformed to IS 1239 etc., complete as directed by the employer. (Market Rate) ---- etc., complete with all leadNos767.0767.030.0FalseNoneNoneFalseNoneFalse23010.00
232521768668NoneV-2 Item No 8.4Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm139.77139.7720.58FalseNoneNoneFalseNoneFalse2876.46660
232476568668NoneV6 Item No 11.3.1Supplying of..... feet-PVC Batten with integrated LEDtube.... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than80. Power Input:220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 2feet - 9/10 W ---- etc., complete with all leadEach669.69669.6924.0FalseNoneNoneFalseNoneFalse16072.560
232492368668NoneV-2 Item No 13.32.1Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal dia Pipes ---- etc., complete with all leadm195.88195.88200.0FalseNoneNoneFalseNoneFalse39176.00
232521868668NoneV-2 Item No 8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm64.4264.4230.24FalseNoneNoneFalseNoneFalse1948.06080
232476668668NoneV6 Item No 11.3.3Supplying of..... feet-PVC Batten with integrated LEDtube.... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than80. Power Input:220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 36/40 W ---- etc., complete with all leadEach1542.341542.3436.0FalseNoneNoneFalseNoneFalse55524.240
232521968668NoneV-1 Item No 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for COLUMNS ---- etc., complete with all leadCum14276.1414276.142.27FalseNoneNoneFalseNoneFalse32406.83780
232492468668NoneV-2 Item No 13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia Pipes ---- etc., complete with all leadm447.22447.22250.0FalseNoneNoneFalseNoneFalse111805.00
232476768668NoneV6 Item No 12.41Supplying & Fixing of 250W/400W High Pressure Sodium Vapour tubular Lamp with Xenon filled gas with luminous efficiency of greater than 140 lumen/W or initial lumens of greater than 55000 lumens & avg rated life greater than 26000hrs. & minimum starting temperature of deg C & Hot re strike time less than 60 Sec with CCT 2000K. Operating voltage range from 180V to 265V, 50Hz AC power Supply ---- etc., complete with all leadEach2156.122156.1210.0FalseNoneNoneFalseNoneFalse21561.20
232522068668NoneV-1 Item No 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RCC BEAMS, RCC SLAB and LINTEL ---- etc., complete with all leadCum13436.3713436.372.9166FalseNoneNoneFalseNoneFalse39188.5167420
232492568668NoneV-2 Item No 13.33.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 20 mm nominal dia Pipes ---- etc., complete with all leadm256.06256.06200.0FalseNoneNoneFalseNoneFalse51212.00
232476868668NoneV6 Item No 11.15Supplying and fixing of LED Bulk head of 10W with IP65 protection and IK 08 impact resistance suitable for surface and wall mounting applications. ---- etc., complete with all leadEach1023.371023.3712.0FalseNoneNoneFalseNoneFalse12280.440
232522168668NoneV-1 Item No 2.1.4Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all leadCum11062.7811062.783.8104FalseNoneNoneFalseNoneFalse42153.6169120
232492668668NoneV-2 Item No 13.33.5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 40 mm nominal dia Pipes ---- etc., complete with all leadm562.86562.86200.0FalseNoneNoneFalseNoneFalse112572.00
232476968668NoneV6 Item No 12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cut outs and other equipment' s on the meter board using 40mm dia 2.90mm thick GI pipe 2.5m long buried in a pit. The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia ---- etc., complete with all leadNos4266.054266.0512.0FalseNoneNoneFalseNoneFalse51192.60
232492768668NoneApproved Rate Supplying, installing, testing and commissioning of approved make full way lever operated forged brass ball valve of brass body with forged brass hard chromeplated steel ball tested to a pressure not less than 20 Kg / sqcm with threaded joints complete. a) 20mm dia (Market Rate) ---- etc., complete with all leadNos649.0649.04.0FalseNoneNoneFalseNoneFalse2596.00
232522268668NoneV-2 Item No 11.32Providing Thermo-Mechanically Treated bars of grade Fe-550D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) ---- etc., complete with all leadTonne109781.63109781.631.4824FalseNoneNoneFalseNoneFalse162740.2883120
232477068668NoneV6 Item No 13.1.2Supplying and Fixing of mm dia class A GI pipe bracket upto 2ms long bent at suitable angle and fixing to this bracket street light fitting of all capacities to GIor GIorrailor RC pole/ wall using suitable clamps, bolts, and nuts and wiring using suitable capacity wires. Using 32mm dia G.I.Pipe ---- etc., complete with all leadEach1270.091270.0910.0FalseNoneNoneFalseNoneFalse12700.90
232522368668None15 Item No 4.21KSRB 4-2.12 : Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. Specification No . KBS ---- etc., complete with all leadRmtr40.1140.113.7FalseNoneNoneFalseNoneFalse148.4070
232492868668NoneApproved Rate Supplying, installing, testing and commissioning of approved make full way lever operated forged brass ball valve of brass body with forged brass hard chromeplated steel ball tested to a pressure not less than 20 Kg / sqcm with threaded joints complete.b) 25mm dia (Market Rate) ---- etc., complete with all leadNos944.0944.02.0FalseNoneNoneFalseNoneFalse1888.00
232477168668NoneV6 Item No 13.5Fixing halogen/metal halide/SVL/IL/LED flood light fitting over existing pole/wall ceiling including clamps,bolts,nuts and wiring using suitable capacity wires. ---- etc., complete with all leadEach196.89196.8910.0FalseNoneNoneFalseNoneFalse1968.90
232522468668NoneItem No 23Providing throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas & parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge. ---- etc., complete with all leadRmtr88.7288.7276.25FalseNoneNoneFalseNoneFalse6764.90
232492968668NoneV-2 Item No 14.55 aProviding and fixing Bib cock with wall flange made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class economy ---- etc., complete with all leadEach1318.061318.062.0FalseNoneNoneFalseNoneFalse2636.120
232477268668NoneV6 Item No 13.7.1Fixing all types and all capacities of fluorescent/false ceiling/spotlight/CFL/LED fittings indoor on the wall/ceiling/rafters/girdersusing23/0.0076 inch twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall/ ceiling / Rafter / Girders ---- etc., complete with all leadEach148.28148.28190.0FalseNoneNoneFalseNoneFalse28173.20
232493068668NoneV-2 Item No 13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank. ---- etc., complete with all leadLtr10.6210.625000.0FalseNoneNoneFalseNoneFalse53100.00
232522568668NoneV-2 Item No 6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete with all leadSqm1607.631607.6397.354FalseNoneNoneFalseNoneFalse156509.211020
232477368668NoneV6 Item No 13.1Fixing a ceiling/Wall mounting fan of all capacities and all types to the existing S hook with fan regulator to the existing board together with supplying and fixing 5A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. ---- etc., complete with all leadEach207.83207.8376.0FalseNoneNoneFalseNoneFalse15795.080
232522668668NoneV-2 Item No 12.9Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all leadSqm8263.968263.961.8FalseNoneNoneFalseNoneFalse14875.1280
232493168668NoneV-5 Item No 16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover ---- etc., complete with all leadLtr6435.726435.7220.0FalseNoneNoneFalseNoneFalse128714.40
232477468668NoneV6 Item No 13.14Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5A.ceiling rose withs ufficient lengthof23/0.0076 inch PVC insulated twin core wire. ---- etc., complete with all leadEach597.98597.9812.0FalseNoneNoneFalseNoneFalse7175.760
232493268668NoneApproved Rate O.T. S.S. Surgical Scrub Station - 2 Bay ; Floor mounted Size:- 2100 x 600 x 1000 + 300 mm LxWxH + Flashback Technical Specifications S.S. 304 Grade ; 16 SWG Floor mounted with slopy radius chamber 2 Electric ON- OFF Foot operated Switches for washing 1 manual Foot operated Valve connected to one Switch 2 manual wire rod Holders for liquid detergent container Flashback at 300 mm Height Nylon adjustable levelling bullets for legs Note: Plumbing and other accessories not in our scope ---- etc., complete with all leadLtr206500.0206500.01.0FalseNoneNoneFalseNoneFalse206500.00
232522768668NoneV-2 Item No 11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- etc., complete with all leadKg206.17206.1737.8FalseNoneNoneFalseNoneFalse7793.2260
232493368668None1.2.1Supplying heavy gauge PVC Conduit pipe…dia.. Mm thick confirming to IS 2509 with suitable size bends, metal/pvc junction boxes,adesive paste etc.., and running before concreting the slab .the conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using pvc end enclosures, run with 185WG GI fish wire wherever necessary. (P.No. 1/.I.No.1.2)PWD Electrical SR 22-23 19/20 mm dia 2mm thick ---- etc., complete with all leadm77.8877.8830.0FalseNoneNoneFalseNoneFalse2336.40
232522868668NoneV-2 Item No 11.5.1Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete with all leadSqm4491.554491.552.52FalseNoneNoneFalseNoneFalse11318.7060
232493468668None1.2.2Supplying heavy gauge PVC Conduit pipe…dia.. Mm thick confirming to IS 2509 with suitable size bends, metal/pvc junction boxes,adesive paste etc.., and running before concreting the slab .the conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using pvc end enclosures, run with 185WG GI fish wire wherever necessary. (P.No. 1/.I.No.1.2)PWD Electrical SR 22-23 25mm dia 2mm thick ---- etc., complete with all leadm92.0492.04450.0FalseNoneNoneFalseNoneFalse41418.00
232522968668NoneV-2 Item No 8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge... ( Inside) ---- etc., complete with all leadSqm382.89382.8924.804FalseNoneNoneFalseNoneFalse9497.203560
232493568668None1.3.1Supplying heavy gauge pvc conduit pipe…dia.. Mm thick confirming to IS 2509 with suitable size bends ,metal junction boxes, adhesive paste etc by groove cutting in the wall and fixing by bracing Uor Jhooks and cement plastering upto the wall surface and run with 18SWG GI fish wire run thoughout the conduit wherever neccessary (P.No. 1/.I.No.1.3)PWD Electrical SR 22-23 19/20 mm dia 2mm thick ---- etc., complete with all leadm82.6582.6520.0FalseNoneNoneFalseNoneFalse1653.00
232523068668NoneV-2 Item No 8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete with all leadSqm122.72122.7242.9661FalseNoneNoneFalseNoneFalse5272.7997920
232493668668None1.3.2Supplying heavy gauge pvc conduit pipe…dia.. Mm thick confirming to IS 2509 with suitable size bends ,metal junction boxes, adhesive paste etc by groove cutting in the wall and fixing by bracing Uor Jhooks and cement plastering upto the wall surface and run with 18SWG GI fish wire run thoughout the conduit wherever neccessary (P.No. 1/.I.No.1.3)PWD Electrical SR 22-23 25mm dia 2mm thick ---- etc., complete with all leadm96.0296.02300.0FalseNoneNoneFalseNoneFalse28806.00
232523168668NoneV-2 Item No 8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. ( Outside) ---- etc., complete with all leadSqm428.29428.29203.1865FalseNoneNoneFalseNoneFalse87022.7460850
232493768668None1.5.1Supplying and fixing PVC/metal conduit Deep junction box (P.No. 1/.I.No.1.5)PWD Electrical SR 22-23 19/20 mm deep junction box ---- etc., complete with all leadEach57.8257.828.0FalseNoneNoneFalseNoneFalse462.560
232523268668NoneV-2 Item No 15.1Providing and Applying PU based Elastomeric Liquid Applied PU Waterproofing Membrane single component, cold applied, water based acrylic PU dispersion with highly elastic and UV resistant water proofing treatment to the Existing Roof surface/Chajjas/Sunken portion of WC:Bathroom applied @ 1.2L/per m2,having tensile strength greater than 1.5N/mm2, elongation greater than 300% with solid content not less than 60% in 2 coats including surface preparation, priming the surface with water based acrylic primer @0.1 L/m2, and spreading 60 gsm geotextile between two top coats completely as per specification. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. Polyurethane based Single Component for New Surface ---- etc., complete with all leadSqm1002.621002.62165.0FalseNoneNoneFalseNoneFalse165432.30
232493868668None1.5.2Supplying and fixing PVC/metal conduit Deep junction box (P.No. 1/.I.No.1.5)PWD Electrical SR 22-23 25 mm deep junction box ---- etc., complete with all leadEach66.0866.0825.0FalseNoneNoneFalseNoneFalse1652.00
232523368668NoneV-2 Item No 8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm155.85155.8542.9661FalseNoneNoneFalseNoneFalse6696.2666850
232493968668None1.11Supplying And Fixing Metal Fan Box with Round Hook. (P.No.2/.I.No.1.11) PWD Electrical SR 22-23 ---- etc., complete with all leadNos142.2142.225.0FalseNoneNoneFalseNoneFalse3555.00
232523468668NoneV-2 Item No 8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm191.44191.44203.1865FalseNoneNoneFalseNoneFalse38898.023560
232494068668None2.2.1Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.(P.No.3/.I.No.2.2) PWD Electrical SR 22-23 short point upto 3mtr from tapping point to out let via switch box ---- etc., complete with all leadPoint317.42317.4230.0FalseNoneNoneFalseNoneFalse9522.60
232523568668NoneV-2 Item No 8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm61.3661.363.9FalseNoneNoneFalseNoneFalse239.3040
232494168668None2.2.2Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.(P.No.3/.I.No.2.2) PWD Electrical SR 22-23 Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch box ---- etc., complete with all leadPoint447.22447.2240.0FalseNoneNoneFalseNoneFalse17888.80
232523668668NoneV-2 Item No 8.4Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm141.13141.133.9FalseNoneNoneFalseNoneFalse550.4070
232494268668None2.2.3Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.(P.No.3/.I.No.2.2) PWD Electrical SR 22-23 Long point above 6Mtr upto 10Mtr from tapping point to out let via switch box ---- etc., complete with all leadPoint654.9654.975.0FalseNoneNoneFalseNoneFalse49117.50
232523768668NoneW.S & UGD SR Item No 647PVC pipe - OD 110mm and 6 Kg/sqcm (Sl No 647 Page No A-44) ---- etc., complete with all leadRmtr312.94312.94216.0FalseNoneNoneFalseNoneFalse67595.040
232494368668None2.2.4Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.(P.No.3/.I.No.2.2) PWD Electrical SR 22-23 Two outlet in a row, above 3Mtr upto 6Mtr from tapping point to out let via switches. ---- etc., complete with all leadPoint798.86798.865.0FalseNoneNoneFalseNoneFalse3994.30
232523868668NoneV-2 Item No 14.28.2.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40mm dia ---- etc., complete with all leadm111.82111.8210.0FalseNoneNoneFalseNoneFalse1118.20
232494468668None2.3.2Wiring for lighting / power circuit using one of FRLS PVC insulated1100V grade multi strand copper with low conductor resistance single core wire in open or consealed system of wiring.as per IS-694:1990 & confirming to latest amendments (P. No.3/ I.No.2.3) PWD Electrical SR 22-23 1.5 sqmrn ---- etc., complete with all leadMtr30.6830.68750.0FalseNoneNoneFalseNoneFalse23010.00
232523968668NoneV-5 Item No 16.7.4Providing and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make including trench excavation and refilling etc. for EXTERNAL WORKS with: 50mm nominal bore pipes ---- etc., complete with all leadm168.94168.948.0FalseNoneNoneFalseNoneFalse1351.520
232494568668None2.3.3Wiring for lighting / power circuit using one of FRLS PVC insulated1100V grade multi strand copper with low conductor resistance single core wire in open or consealed system of wiring.as per IS-694:1990 & confirming to latest amendments (P. No.3/ I.No.2.3) PWD Electrical SR 22-23 2.5 sqmrn ---- etc., complete with all leadMtr49.5649.561200.0FalseNoneNoneFalseNoneFalse59472.00
232524068668NoneV-5 Item No 657PVC pipe - OD 75mm and 6 Kg/sqcm (Sl.No 657 Page No A-44) ---- etc., complete with all leadm149.49149.49135.0FalseNoneNoneFalseNoneFalse20181.150
232494668668None2.3.4Wiring for lighting / power circuit using one of FRLS PVC insulated1100V grade multi strand copper with low conductor resistance single core wire in open or consealed system of wiring.as per IS-694:1990 & confirming to latest amendments (P. No.3/ I.No.2.3) PWD Electrical SR 22-23 4.0 sqmrn ---- etc., complete with all leadMtr74.3474.34400.0FalseNoneNoneFalseNoneFalse29736.00
232524168668NoneV-5 Item No 647PVC pipe - OD 110mm and 6 Kg/sqcm (Sl.No 647 Page No A-44) ---- etc., complete with all leadm309.93309.93100.0FalseNoneNoneFalseNoneFalse30993.00
232494768668None2.6.2Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirmining to table 3 class 5 of IS:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100Volts as per IS:694-1990 (P.No.4/.I.No.2.6) PWD Electrical SR 22-23 3C X 4.0Sq.mm ---- etc., complete with all leadMtr198.24198.24100.0FalseNoneNoneFalseNoneFalse19824.00
232524268668NoneV-2 Item No 13.47Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 75mm diameter ---- etc., complete with all leadm239.43239.4320.0FalseNoneNoneFalseNoneFalse4788.60
232524368668None2018-19 SR Item No 37.28.1Drilling holes of 2.50 cms dia (roof/chajja/stone). in slabs upto 7.50 cms thick. (CIVIL SR 2018-19) ---- etc., complete with all leadNos159.22159.2210.0FalseNoneNoneFalseNoneFalse1592.20
232494868668None3.4.1Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall (P. No.5/ I.No.3.4)PWD Electrical SR 22-23 1-2Way ---- etc., complete with all leadEach162.84162.8410.0FalseNoneNoneFalseNoneFalse1628.40
232524468668None2018-19 SR Item No 37.28.2Drilling holes of 2.50 cms dia (roof/chajja/stone). in slabs upto 10 cms thick. (CIVIL SR 2018-19) ---- etc., complete with all leadNos190.82190.825.0FalseNoneNoneFalseNoneFalse954.10
232494968668None3.4.2Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall (P. No.5/ I.No.3.4)PWD Electrical SR 22-23 3 Way ---- etc., complete with all leadEach187.62187.628.0FalseNoneNoneFalseNoneFalse1500.960
232495068668None3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall (P. No.5/ I.No.3.4)PWD Electrical SR 22-23 4-5Way ---- etc., complete with all leadEach208.86208.866.0FalseNoneNoneFalseNoneFalse1253.160
232524568668NoneV-2 Item No 14.31Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. ---- etc., complete with all leadNos1180.151180.154.0FalseNoneNoneFalseNoneFalse4720.60
232495168668None3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall (P. No.5/ I.No.3.4)PWD Electrical SR 22-23 6Way ---- etc., complete with all leadEach259.6259.610.0FalseNoneNoneFalseNoneFalse2596.00
232524668668NoneV-2 Item No 13.9.2Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter ---- etc., complete with all leadNos339.1339.14.0FalseNoneNoneFalseNoneFalse1356.40
232495268668None3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall (P. No.5/ I.No.3.4)PWD Electrical SR 22-23 8 Way ---- etc., complete with all leadEach307.98307.9818.0FalseNoneNoneFalseNoneFalse5543.640
232524768668NoneV-2 Item No 14.22BProviding and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. ---- etc., complete with all leadNos6760.056760.051.0FalseNoneNoneFalseNoneFalse6760.050
232495368668None3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall (P. No.5/ I.No.3.4)PWD Electrical SR 22-23 10-12Way ---- etc., complete with all leadEach376.42376.422.0FalseNoneNoneFalseNoneFalse752.840
232524868668NoneV-2 Item No 14.35Providing and fixing vitreous china dual purpose closet suitable for use as squatting pan or European type water closet (Anglo Indian W.C pan) with seat & lid fixed with C.P. brass hinges and rubber buffers, 10 litre low level flushing cistern with fitting and brackets, 40 mm flush bend, 20 mm over flow pipe, with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: ---- etc., complete with all leadNos10491.3310491.332.0FalseNoneNoneFalseNoneFalse20982.660
232495468668None3.5.1Supplying and fixing superior quality modular switch mounting polycorbonate plate with neceaary supporting back plate with rquired nos. of machine screwes, bolts nuts etc., complete on the existing metal/PVC box. (P. No.5/ I.No.3.5)PWD Electrical SR 22-23 1 to 2 Module ---- etc., complete with all leadEach161.66161.6610.0FalseNoneNoneFalseNoneFalse1616.60
232524968668NoneV-2 Item No 14.10.1.4Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board-510x1040 mm bowl depth 178 mm ---- etc., complete with all leadNos5872.815872.814.0FalseNoneNoneFalseNoneFalse23491.240
232495568668None3.5.2Supplying and fixing superior quality modular switch mounting polycorbonate plate with neceaary supporting back plate with rquired nos. of machine screwes, bolts nuts etc., complete on the existing metal/PVC box. (P. No.5/ I.No.3.5)PWD Electrical SR 22-23 3 Module ---- etc., complete with all leadEach189.98189.988.0FalseNoneNoneFalseNoneFalse1519.840
232525068668NoneV-2 Item No 166C.P. Brass stop cock (concealed) 15 mm Sl.no.- 166 Page No A-16 ---- etc., complete with all leadNos638.09638.0912.0FalseNoneNoneFalseNoneFalse7657.080
232495668668None3.5.3Supplying and fixing superior quality modular switch mounting polycorbonate plate with neceaary supporting back plate with rquired nos. of machine screwes, bolts nuts etc., complete on the existing metal/PVC box. (P. No.5/ I.No.3.5)PWD Electrical SR 22-23 4 Module ---- etc., complete with all leadEach206.5206.56.0FalseNoneNoneFalseNoneFalse1239.00
232525168668NoneV-2 Item No 14.7.10Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps ---- etc., complete with all leadNos3745.863745.867.0FalseNoneNoneFalseNoneFalse26221.020
232495768668None3.5.4Supplying and fixing superior quality modular switch mounting polycorbonate plate with neceaary supporting back plate with rquired nos. of machine screwes, bolts nuts etc., complete on the existing metal/PVC box. (P. No.5/ I.No.3.5)PWD Electrical SR 22-23 6 Module ---- etc., complete with all leadEach276.12276.1210.0FalseNoneNoneFalseNoneFalse2761.20
232525268668NoneV-2 Item No 13.32.1Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal dia Pipes ---- etc., complete with all leadm375.56375.56100.0FalseNoneNoneFalseNoneFalse37556.00
232495868668None3.5.4Supplying and fixing superior quality modular switch mounting polycorbonate plate with neceaary supporting back plate with rquired nos. of machine screwes, bolts nuts etc., complete on the existing metal/PVC box. (P. No.5/ I.No.3.5)PWD Electrical SR 22-23 8 Module ---- etc., complete with all leadEach335.12335.1218.0FalseNoneNoneFalseNoneFalse6032.160
232525368668NoneV-2 Item No 13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia Pipes ---- etc., complete with all leadm460.64460.6475.0FalseNoneNoneFalseNoneFalse34548.00
232495968668None3.5.5Supplying and fixing superior quality modular switch mounting polycorbonate plate with neceaary supporting back plate with rquired nos. of machine screwes, bolts nuts etc., complete on the existing metal/PVC box. (P. No.5/ I.No.3.5)PWD Electrical SR 22-23 10-12 Module ---- etc., complete with all leadEach405.92405.922.0FalseNoneNoneFalseNoneFalse811.840
232525468668NoneV-2 Item No 13.32.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal dia Pipes ---- etc., complete with all leadm579.75579.7525.0FalseNoneNoneFalseNoneFalse14493.750
232496068668None3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per 3854 and IS 1293. (P. No.5/ I.No.3.6)PWD Electrical SR 22-23 6Amps one way. ---- etc., complete with all leadEach120.36120.36275.0FalseNoneNoneFalseNoneFalse33099.00
232525568668NoneV-2 Item No 13.32.4Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32 mm nominal dia Pipes ---- etc., complete with all leadm676.98676.9825.0FalseNoneNoneFalseNoneFalse16924.50
232496168668None3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per 3854 and IS 1293. (P. No.5/ I.No.3.6)PWD Electrical SR 22-23 6Amps two way.switch ---- etc., complete with all leadEach195.88195.882.0FalseNoneNoneFalseNoneFalse391.760
232525668668NoneV-2 Item No 13.31.5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.internal work - exposed on wall 40 mm nominal dia Pipes ---- etc., complete with all leadm651.45651.4525.0FalseNoneNoneFalseNoneFalse16286.250
232496268668None3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per 3854 and IS 1293. (P. No.5/ I.No.3.6)PWD Electrical SR 22-23 6Amps 3way socket. ---- etc., complete with all leadEach201.78201.7875.0FalseNoneNoneFalseNoneFalse15133.50
232525768668NoneV-2 Item No 13.33.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 50 mm nominal dia Pipes ---- etc., complete with all leadm876.3876.375.0FalseNoneNoneFalseNoneFalse65722.50
232496368668None3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per 3854 and IS 1293. (P. No.5/ I.No.3.6)PWD Electrical SR 22-23 Stepped Fan Regulator. ---- etc., complete with all leadEach421.26421.2620.0FalseNoneNoneFalseNoneFalse8425.20
232525868668NoneV-2 Item No 109Brass full way valve with C.I. wheel (screwed end) 25 mm dia. (Sl No 109 Page No .A-15) ---- etc., complete with all leadNos455.78455.7820.0FalseNoneNoneFalseNoneFalse9115.60
232496468668None3.6.8Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per 3854 and IS 1293. (P. No.5/ I.No.3.6)PWD Electrical SR 22-23 16Amps one way switch ---- etc., complete with all leadEach212.4212.46.0FalseNoneNoneFalseNoneFalse1274.40
232525968668NoneV-2 Item No 110Brass full way valve with C.I. wheel (screwed end) 32 mm dia. (Sl No 109 Page No .A-15) ---- etc., complete with all leadNos504.39504.3920.0FalseNoneNoneFalseNoneFalse10087.80
232496568668None3.6.9Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per 3854 and IS 1293. (P. No.5/ I.No.3.6)PWD Electrical SR 22-23 6Amps Bell push ---- etc., complete with all leadEach208.86208.861.0FalseNoneNoneFalseNoneFalse208.860
232526068668NoneV-2 Item No 86Brass bib-cock 15 mm dia ---- etc., complete with all leadNos194.46194.466.0FalseNoneNoneFalseNoneFalse1166.760
232496668668None3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per 3854 and IS 1293. (P. No.5/ I.No.3.6)PWD Electrical SR 22-23 32Amps DP switch ---- etc., complete with all leadEach384.68384.6810.0FalseNoneNoneFalseNoneFalse3846.80
232526168668NoneV-2 Item No 8.5.1Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix 1:3 (1 cement: 3 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm444.84444.843.9FalseNoneNoneFalseNoneFalse1734.8760
232496768668None3.6.11Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per 3854 and IS 1293. (P. No.5/ I.No.3.6)PWD Electrical SR 22-23 6/16Amps universal socket ---- etc., complete with all leadEach278.48278.4810.0FalseNoneNoneFalseNoneFalse2784.80
232526268668NoneV-2 Item No 13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank. ---- etc., complete with all leadLtr10.9410.941000.0FalseNoneNoneFalseNoneFalse10940.00
232496868668None3.14.5Supplying and fixing/replacing of 6/16/32Amps electrical accessories on existing switch board. (P. No.6/ I.No.3.14) PWD Electrical SR 22-23 6Amps Bakelite ceiling rose ---- etc., complete with all leadNos92.0492.0410.0FalseNoneNoneFalseNoneFalse920.40
232526368668NoneV-1 Item No 1.5Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depth ---- etc., complete with all leadCum278.33278.3387.0FalseNoneNoneFalseNoneFalse24214.710
232496968668None3.14.6Supplying and fixing/replacing of 6/16/32Amps electrical accessories on existing switch board. (P. No.6/ I.No.3.14) PWD Electrical SR 22-23 6 Amps pendant holder ---- etc., complete with all leadNos83.7883.7840.0FalseNoneNoneFalseNoneFalse3351.20
232526468668NoneV-5 Item No 10.2.4Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:( For external Sanitary Work ). Pipes of SN4, 160mm dia. ---- etc., complete with all leadm700.07700.0760.0FalseNoneNoneFalseNoneFalse42004.20
232497068668None3.8Supplying 4mm thick plastic sheet with necessary nitches for fixing switches regulators etc., and fixing on existing wooden or metal box using N.F. screws.(P. No.6/ I.No.3.8) PWD Electrical SR 22-23 ---- etc., complete with all leadSq CM0.480.481000.0FalseNoneNoneFalseNoneFalse480.00
232526568668NoneV-5 Item No 10.2.5Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:( For external Sanitary Work ). Pipes of SN4, 200mm dia. ---- etc., complete with all leadm1010.01010.060.0FalseNoneNoneFalseNoneFalse60600.00
232497168668None3.10.1supplying 4mm thick white plastic plate and covering for junction boxes or size ... mm conduit using necessary machine screws. (P. No.6/ I.No.3.10) PWD Electrical SR 22-23 80/90mm ---- etc., complete with all leadEach17.717.710.0FalseNoneNoneFalseNoneFalse177.00
232526668668NoneV-5 Item No 16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.. ---- etc., complete with all leadNos6628.796628.7910.0FalseNoneNoneFalseNoneFalse66287.90
232526768668None2018-19 SR 12.112.2Providing stoneware gully trap of approved quality and make fixing in M-15 and plastering with CM 1:3 wherever necessary.( Rate includes cost of all materials, fixtures and lead).15cms x 10cms. (SR. 2018-19) ---- etc., complete with all leadNos340.31340.3110.0FalseNoneNoneFalseNoneFalse3403.10
232497268668None3.10.2supplying 4mm thick white plastic plate and covering for junction boxes or size ... mm conduit using necessary machine screws. (P. No.6/ I.No.3.10) PWD Electrical SR 22-23 110mm ---- etc., complete with all leadEach24.7824.7810.0FalseNoneNoneFalseNoneFalse247.80
232497368668None5.11.3Supplying of on load change over switches 4 poles,AC-23 Aduty 415V, 50Hz, AC Supply.open execution (P.No.11/.I.No.5.11) PWD Electrical SR 22-23 125 Amps ---- etc., complete with all leadEach12184.6812184.681.0FalseNoneNoneFalseNoneFalse12184.680
232526868668NoneV-5 Item No 16.37Providing and fixing 150mm dia. Cast Iron pipe for ventilatiing shaft 5 M high with specials and cowl and with suitable grips in CC 1:2:4 pillar using 10mm to 20mm graded hard granite, with 15 cms. thick cement concrete 1:2:4 around upto 1.22 M above the GLR and with a foundation base of 90 x 90 x 90 cms. plastered with 12mm thick CM 1:3 to all exposed faces and linking the shaft to the manholes by means of 150mm dia. GSW pipes and specials, jointing with tar dipped hemp 1:1.5 CM caulking, curing. The cost include all lead and lifts for all materials, earth work excavations and refilling in all strata, disposal of surplus earth etc. complete ---- etc., complete with all leadNos25629.1425629.141.0FalseNoneNoneFalseNoneFalse25629.140
232497468668None5.15.1Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. (P.No.12/.I.No.5.14)PWD Electrical SR 22-23 FOUR POLE 100Amps25kA. ---- etc., complete with all leadEach7181.487181.481.0FalseNoneNoneFalseNoneFalse7181.480
232526968668NoneV-2 Item No 13.23.5Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. 50 mm nominal bore, 242mm long, weighing not less than 1240 g ---- etc., complete with all leadNos1633.51633.52.0FalseNoneNoneFalseNoneFalse3267.00
232497568668None5.14Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. (P.No.12/.I.No.5.14)PWD Electrical SR 22-23 FOUR POLE 125Amps25kA. ---- etc., complete with all leadEach10145.6410145.643.0FalseNoneNoneFalseNoneFalse30436.920
232527068668NoneELECTRICAL SR CODE No 2.2.1Point wiring using Copper wire without switch Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point up to 3Mtr from tapping point to out let via switch box ---- etc., complete with all leadPoint326.94326.9422.0FalseNoneNoneFalseNoneFalse7192.680
232497668668None5.15Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. (P.No.12/.I.No.5.14)PWD Electrical SR 22-23 FOUR POLE Supplying and fixing of Shunt trip suitable for MCCB.CBCT. (P.No.12/.I.No.5.15)PWD Electrical SR 22-23 ---- etc., complete with all leadEach2009.542009.541.0FalseNoneNoneFalseNoneFalse2009.540
232527168668NoneELECTRICAL SR CODE No 2.2.2Point wiring using Copper wire without switch Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch box ---- etc., complete with all leadPoint460.64460.6418.0FalseNoneNoneFalseNoneFalse8291.520
232497768668None5.18.4Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C type curve indicator on/off energy cross 3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.(P.No.13/.I.No.5.17)PWD Electrical SR 22-23 6-32Amps DP ---- etc., complete with all leadEach872.02872.026.0FalseNoneNoneFalseNoneFalse5232.120
232527268668NoneELECTRICAL SR CODE No 2.2.3Point wiring using Copper wire without switch Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switch box ---- etc., complete with all leadPoint674.55674.5520.0FalseNoneNoneFalseNoneFalse13491.00
232497868668None5.18.6Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C type curve indicator on/off energy cross 3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.(P.No.13/.I.No.5.17)PWD Electrical SR 22-23 50-63Amps DP ---- etc., complete with all leadEach1300.361300.366.0FalseNoneNoneFalseNoneFalse7802.160
232527368668NoneELECTRICAL SR CODE No 3.4.1Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-2Way ---- etc., complete with all leadEach167.73167.7310.0FalseNoneNoneFalseNoneFalse1677.30
232497968668None5.18.7Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C type curve indicator on/off energy cross 3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.(P.No.13/.I.No.5.17)PWD Electrical SR 22-23 6-32Amps TPN ---- etc., complete with all leadEach2026.062026.068.0FalseNoneNoneFalseNoneFalse16208.480
232527468668NoneELECTRICAL SR CODE No 3.4.2Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3Way ---- etc., complete with all leadEach193.25193.255.0FalseNoneNoneFalseNoneFalse966.250
232498068668None5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C type curve indicator on/off energy cross 3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.(P.No.13/.I.No.5.17)PWD Electrical SR 22-23 50-63Amps TPN ---- etc., complete with all leadEach3643.843643.846.0FalseNoneNoneFalseNoneFalse21863.040
232527568668NoneELECTRICAL SR CODE No 3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5Way ---- etc., complete with all leadEach215.13215.135.0FalseNoneNoneFalseNoneFalse1075.650
232498168668None5.19.9Supplying and fixing regular MCB distribution boards on wall / woodboard/flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting etc., made out of 14 SWG MS enclosures. .(P.No.13/.I.No.5.18)PWD Electrical SR 22-23 II Double Door 12WaySP&N ---- etc., complete with all leadEach2748.222748.222.0FalseNoneNoneFalseNoneFalse5496.440
232527668668NoneELECTRICAL SR CODE No 3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6Way ---- etc., complete with all leadEach267.39267.396.0FalseNoneNoneFalseNoneFalse1604.340
232498268668None5.19.12Supplying and fixing regular MCB distribution boards on wall / woodboard/flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting etc., made out of 14 SWG MS enclosures. .(P.No.13/.I.No.5.18)PWD Electrical SR 22-23 III - Double Door 6WayTP &N ---- etc., complete with all leadEach5829.25829.22.0FalseNoneNoneFalseNoneFalse11658.40
232527768668NoneELECTRICAL SR CODE No 3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8Way ---- etc., complete with all leadEach317.22317.222.0FalseNoneNoneFalseNoneFalse634.440
232498368668None5.21Supplying,fixingandwiringearthleakagerelaywithcorebalancedcurrenttransformersuitableforsinglephase50HzACwithlatestmicrocontrollerbased,digitalreadoutofpercentageleakagecurrent,programmabledelay/auto/manualresetfacilitysuitabletomountonDIN rail/ flush mounting on panel board. ---- etc., complete with all leadEach10920.910920.91.0FalseNoneNoneFalseNoneFalse10920.90
232527868668NoneELECTRICAL SR CODE No 3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way ---- etc., complete with all leadEach387.71387.712.0FalseNoneNoneFalseNoneFalse775.420
232498468668None5.31Supplying and fixing Electronic Trivector Meter (ETV) suitable for operation LT operation and -CT operated meter in polycarbonate body in class 0.5 accuracy as per IS 14697 and completely wired..(P.No.14/.I.No.5.31) PWD Electrical SR 22-23 ---- etc., complete with all leadEach5180.25180.21.0FalseNoneNoneFalseNoneFalse5180.20
232527968668NoneELECTRICAL SR CODE No 3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 Module ---- etc., complete with all leadEach166.51166.5130.0FalseNoneNoneFalseNoneFalse4995.30
232498568668None5.33Supplying of multi function digital Meter three line back light LCD type display of voltage, Current, frequency.Power, power factor, KVA, KWH.KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required.with communication port and class 0.5s accuracy.(P.No.14/.I.No.5.33) PWD Electrical SR 22-23 ---- etc., complete with all leadEach10991.710991.71.0FalseNoneNoneFalseNoneFalse10991.70
232528068668NoneELECTRICAL SR CODE No 3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3 Module ---- etc., complete with all leadEach195.68195.6810.0FalseNoneNoneFalseNoneFalse1956.80
232498668668None5.34Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accurecy with tape wound . (P.No.14/.I.No.5.34) PWD Electrical SR 22-23 ---- etc., complete with all leadEach663.16663.163.0FalseNoneNoneFalseNoneFalse1989.480
232528168668NoneELECTRICAL SR CODE No 3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4Moudule ---- etc., complete with all leadEach212.7212.715.0FalseNoneNoneFalseNoneFalse3190.50
232498768668None5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C. (P.No.14/.I.No.5.38) PWD Electrical SR 22-23 ---- etc., complete with all leadEach607.7607.79.0FalseNoneNoneFalseNoneFalse5469.30
232528268668NoneELECTRICAL SR CODE No 3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6Moudule ---- etc., complete with all leadEach284.4284.46.0FalseNoneNoneFalseNoneFalse1706.40
232498868668None5.40.2Supplying.........amps rated 3phase with neutral bus bar using requiemed capacity electrolyticaluminium strips covered with heat shrinkable couloured PVC sleeve, mounted on phenolic/FRP/DMC insulator whcih are mounted on powder coated 40x6mm M.S.tlat frame work in existing panel board.The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary botls,nuts and washers etc., complete. (P.No.15/.I.No.5.40) PWD Electrical SR 22-23 250Arnps 4x30x10mm Alluminium Strips ---- etc., complete with all leadRmtr4053.34053.34.0FalseNoneNoneFalseNoneFalse16213.20
232528368668NoneELECTRICAL SR CODE No 3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8Moudule ---- etc., complete with all leadEach345.17345.1710.0FalseNoneNoneFalseNoneFalse3451.70
232498968668None5.41.2Supplying and fixing angle iron frame work fabricated out of M.S. angle iron., and M.S. flat... with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.(P.No.15/.I.No.5.41) PWD Electrical SR 22-23 50x50x6mm ---- etc., complete with all leadRmtr466.1466.115.0FalseNoneNoneFalseNoneFalse6991.50
232528468668NoneELECTRICAL SR CODE No 3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10Moudule ---- etc., complete with all leadEach418.1418.110.0FalseNoneNoneFalseNoneFalse4181.00
232499068668None5.42.1Fabricating supplying and mounting MS box made out ... SWG suitable for floor/wall mounting, fully weatherproof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete. ((P.No.15/.I.No.5.42) PWD Electrical SR 22-23 14SWG ---- etc., complete with all leadSq CM0.590.59135000.0FalseNoneNoneFalseNoneFalse79650.00
232528568668NoneELECTRICAL SR CODE No 3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way. ---- etc., complete with all leadEach123.97123.9710.0FalseNoneNoneFalseNoneFalse1239.70
232499168668None6.2.1Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete..(P.No.22/.I.No.6.2) PWD Electrical SR 22-23 12" Sweep (300mm) ---- etc., complete with all leadEach3503.423503.424.0FalseNoneNoneFalseNoneFalse14013.680
232528668668NoneELECTRICAL SR CODE No 3.6.2Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps Two way. ---- etc., complete with all leadEach201.76201.765.0FalseNoneNoneFalseNoneFalse1008.80
232499268668None6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system.(.(P.No.16/.I.No.5.47) PWD Electrical SR 22-23 48" Sweep (1200mm) Regular model ---- etc., complete with all leadEach3521.123521.1222.0FalseNoneNoneFalseNoneFalse77464.640
232528768668NoneELECTRICAL SR CODE No 3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A three way socket. ---- etc., complete with all leadEach207.83207.835.0FalseNoneNoneFalseNoneFalse1039.150
232499368668None6.5.1Supplying wall mounting fan suitable to operate at single- phase 230v AC. supply..(P.No.23/.I.No.6.5) PWD Electrical SR 22-23 300mm Sweep ---- etc., complete with all leadEach2940.562940.562.0FalseNoneNoneFalseNoneFalse5881.120
232528868668NoneELECTRICAL SR CODE No 3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator Two Module ---- etc., complete with all leadEach433.9433.96.0FalseNoneNoneFalseNoneFalse2603.40
232499468668None8.1Supplying and drawing UTP-CAT 6E LAN cable.(P.No.27/.I.No.8.1) PWD Electrical SR 22-23 ---- etc., complete with all leadTonne44.8444.84110.0FalseNoneNoneFalseNoneFalse4932.40
232528968668NoneELECTRICAL SR CODE No 3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32A DP switch ---- etc., complete with all leadEach396.22396.223.0FalseNoneNoneFalseNoneFalse1188.660
232499568668None8.4.1Supplying & Fixing of switch mounting rack with power manager & Cable manager..(P.No.28/.I.No.8.4) PWD Electrical SR 22-23 4U with 450mm depth ---- etc., complete with all leadEach5772.565772.561.0FalseNoneNoneFalseNoneFalse5772.560
232529068668NoneELECTRICAL SR CODE No 3.6.11Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16A universal socket ---- etc., complete with all leadEach286.83286.833.0FalseNoneNoneFalseNoneFalse860.490
232499668668None8.9.7Supplying fixing of Network Switches 8 port 10/100 Switch ---- etc., complete with all leadEach1239.01239.01.0FalseNoneNoneFalseNoneFalse1239.00
232529168668NoneELECTRICAL SR CODE No 3.6.12Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. TV/Telephone socket ---- etc., complete with all leadEach189.6189.61.0FalseNoneNoneFalseNoneFalse189.60
232499768668None8.10.1Supplying & fixing of I/O socket with back box.(P.No.28/.I.No.8.10) PWD Electrical SR 22-23 Single I/O ---- etc., complete with all leadEach578.2578.25.0FalseNoneNoneFalseNoneFalse2891.00
232529268668NoneELECTRICAL SR CODE No 12.2.1Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Dong Bell ---- etc., complete with all leadEach298.99298.991.0FalseNoneNoneFalseNoneFalse298.990
232499868668None11.3.2supplying of ...feet PVC batten integrated LED tube ... Wattts with high quality diffuser with life of 25000 burning hours & 70% lumen maintenance with CRI more than 80 power input 220v-240v @ 50HZ & power factor more than .9 along with CE apporved. 2 years warranty aganist any manufacturing defect working under electrical condition (P. No.34/ I.No.11.3) PWD Electrical SR 2022 -23 LED light fitting 1X4' 20/22 watts ---- etc., complete with all leadEach814.2814.230.0FalseNoneNoneFalseNoneFalse24426.00
232529368668NoneELECTRICAL SR CODE No 1.12Supplying and Fixing Metal Fan Box with Round Hook. ---- etc., complete with all leadNo142.2142.26.0FalseNoneNoneFalseNoneFalse853.20
232499968668None11.6.2Supplying of recess mounting non integral type ........ LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRI more than 70%. efficacy more than 100 lumen per watt, 120degree beam spread, life more than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF more than 0.95, power loss should less than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition..(P.No.34/.I.No.11.6) PWD Electrical SR 22-23 LED modular down light 1 'x1' 34 -22watts ---- etc., complete with all leadNos4356.564356.564.0FalseNoneNoneFalseNoneFalse17426.240
232529468668NoneELECTRICAL SR CODE No 1.2.1Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 19/20mm dia 2mm thick ---- etc., complete with all leadMtr80.2280.22200.0FalseNoneNoneFalseNoneFalse16044.00
232500068668None11.6.5Supplying of recess mounting non integral type ........ LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRI more than 70%. efficacy more than 100 lumen per watt, 120degree beam spread, life more than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF more than 0.95, power loss should less than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition..(P.No.34/.I.No.11.6) PWD Electrical SR 22-23 LED modular down light 2'x2' /1' X 4' 34 -36watt ---- etc., complete with all leadNos6959.646959.644.0FalseNoneNoneFalseNoneFalse27838.560
232529568668NoneELECTRICAL SR CODE No 1.2.2Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 25mm dia 2mm thick ---- etc., complete with all leadMtr94.894.8200.0FalseNoneNoneFalseNoneFalse18960.00
232500168668None11.8. 4Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT more than 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire more than IK08. Power Factor more than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency more than 1301m/w, nominal CRI more than 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source..(P.No.36/.I.No.11.8) PWD Electrical SR 22-23 LED Streetlight 90 Watts ---- etc., complete with all leadNos10454.810454.85.0FalseNoneNoneFalseNoneFalse52274.00
232529668668NoneELECTRICAL SR CODE No 1.2.3Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 32mm dia 2.5mm thick ---- etc., complete with all leadMtr125.19125.1950.0FalseNoneNoneFalseNoneFalse6259.50
232500268668None11.11.6Supplying & fixing of retrofit type - LED bulb ...... W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI more than 70%. efficacy more than 80 lumen per watt, life more than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF more than 0.95, power loss should less than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition..(P.No.38/.I.No.11.11) PWD Electrical SR 22-23 15W, 6500K ---- etc., complete with all leadEach384.68384.6810.0FalseNoneNoneFalseNoneFalse3846.80
232529768668NoneELECTRICAL SR CODE No 1.3.1Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19/20mm dia 2mm thick ---- etc., complete with all leadMtr82.6582.6550.0FalseNoneNoneFalseNoneFalse4132.50
232500368668None12.2.2Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote.(P.No.39/.I.No.12.2) PWD Electrical SR 22-23 Musical ---- etc., complete with all leadEach512.12512.121.0FalseNoneNoneFalseNoneFalse512.120
232529868668NoneELECTRICAL SR CODE No 1.3.2Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 25mm dia 2mm thick ---- etc., complete with all leadMtr96.0296.0240.0FalseNoneNoneFalseNoneFalse3840.80
232500468668None13.7Fixing all types and all capacities fluorescent/false ceiling/spot light/ CFL/LED fittings indoor on the wall /ceiling/rafters/girders using 23/ 0.0076" twin twisted PVC insulated wires, required nos of round blocks and clamps (P.No.45/.I.No.13.7)) On wall/ceiling/Rafter/Girders PWD Electrical SR 2022 ---- etc., complete with all leadEach143.96143.9638.0FalseNoneNoneFalseNoneFalse5470.480
232529968668NoneELECTRICAL SR CODE No 1.3.3Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 32mm dia 2.5mm thick ---- etc., complete with all leadMtr120.32120.3220.0FalseNoneNoneFalseNoneFalse2406.40
232500568668None13.11Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.(P.No.46/.I.No.13.10) PWD ellectrical SR 2022 - 23 ---- etc., complete with all leadEach371.7371.724.0FalseNoneNoneFalseNoneFalse8920.80
232530068668NoneELECTRICAL SR CODE No 2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper with low conductor resistance single core cable in open or concealed system of wiring with specified IS-694:1990 & comfirming to 1.5 sqmm ---- etc., complete with all leadMtr31.631.6250.0FalseNoneNoneFalseNoneFalse7900.00
232500668668None13.13Fixing one exhaust fan after making a suitable notch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 A, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.. (P.No.46/.I.No.13.13) PWD Electrical SR 2022 - 23 ---- etc., complete with all leadEach834.26834.264.0FalseNoneNoneFalseNoneFalse3337.040
232530168668NoneELECTRICAL SR CODE No 2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper with low conductor resistance single core cable in open or concealed system of wiring with specified IS-694:1990 & comfirming to 2.5 sqmm ---- etc., complete with all leadMtr51.0551.05250.0FalseNoneNoneFalseNoneFalse12762.50
232500768668None13.1.2Supplying and Fixing........mm dia class A GI pipe bracket upto 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/tubular pole, using suitable clA, bolts, nuts and wiring using suitable capacity wires.(P.No.45/.I.No.13.1) PWD Electrical SR 2022 - 23 Using 32mm dia G.I.Pipe ---- etc., complete with all leadEach1233.11233.15.0FalseNoneNoneFalseNoneFalse6165.50
232530268668NoneELECTRICAL SR CODE No 2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper with low conductor resistance single core cable in open or concealed system of wiring with specified IS-694:1990 & comfirming to 4 sqmm ---- etc., complete with all leadMtr76.5776.57100.0FalseNoneNoneFalseNoneFalse7657.00
232500868668None13.18Fixing of ..... A TPST / change over switch / Contactor along with neutral link with screws, bolts, nuts and wiring using required capacity wires and circuit labelling.(P.No.46/.I.No.13.18) PWD Electrical SR 2022 - 23 100A to 250A TPDT/COS ---- etc., complete with all leadEach527.46527.461.0FalseNoneNoneFalseNoneFalse527.460
232530368668NoneELECTRICAL SR CODE No 2.3.5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper with low conductor resistance single core cable in open or concealed system of wiring with specified IS-694:1990 & comfirming to 6 sqmm ---- etc., complete with all leadMtr111.82111.8250.0FalseNoneNoneFalseNoneFalse5591.00
232500968668None1.01RCC Pole - 9 Mtr Long, 145 Kg WL (Dwg No. BESCOM/GM/QS&S/02 Dtd 24.11.2018) as per IS-785 (P.No.01/.I.No.1) BESCOM SR 2021 - 22 PART III ---- etc., complete with all leadNos8349.688349.685.0FalseNoneNoneFalseNoneFalse41748.40
232530468668NoneELECTRICAL SR CODE No 5.19.8Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure Double Door 8 Way SP & N ---- etc., complete with all leadEach2253.352253.351.0FalseNoneNoneFalseNoneFalse2253.350
232501068668None2.0411 kV, Special 3 Pin Cross Arm - GI (P.No.01/.I.No.14) BESCOM SR 2021 - 22 PART III ---- etc., complete with all leadNos1358.181358.184.0FalseNoneNoneFalseNoneFalse5432.720
232530568668NoneELECTRICAL SR CODE No 5.19.9Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure Double Door 12 Way SP & N ---- etc., complete with all leadEach2830.672830.672.0FalseNoneNoneFalseNoneFalse5661.340
232501168668None2.06LT 4 Pin Cross Arm - GI (P.No.01/.I.No.16) BESCOM SR 2021 - 22 PART III ---- etc., complete with all leadNos447.22447.222.0FalseNoneNoneFalseNoneFalse894.440
232530668668NoneELECTRICAL SR CODE No 5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32A SP ---- etc., complete with all leadEach504.39504.395.0FalseNoneNoneFalseNoneFalse2521.950
232501268668None5.04RCC Pole Clamp - GI (P.No.02/.I.No.32) BESCOM SR 2021 - 22 PART III ---- etc., complete with all leadNos112.1112.15.0FalseNoneNoneFalseNoneFalse560.50
232530768668NoneELECTRICAL SR CODE No 5.20.1Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board 16-25 A 2 pole ---- etc., complete with all leadEach5198.275198.272.0FalseNoneNoneFalseNoneFalse10396.540
232501368668None5.1Guy Clamp - GI (P.No.01/.I.No.40) BESCOM SR 2021 - 22 PART III ---- etc., complete with all leadNos135.7135.72.0FalseNoneNoneFalseNoneFalse271.40
232530868668NoneELECTRICAL SR CODE No 51.04Rod type of earthing using 40 mm Dia, 3 Mtr long MS rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal & connected to equipment ground terminal using PVC Al wire as specified. ( Item No 51.04, SL No 392 ESCOMs SR 2023-24) ---- etc., complete with all leadNo2639.852639.852.0FalseNoneNoneFalseNoneFalse5279.70
232501468668None5.13Anchor Rod using 12 mm rounds/Guy Rod - GI (P.No.02/.I.No.43) BESCOM SR 2021 - 22 PART III ---- etc., complete with all leadNos388.22388.222.0FalseNoneNoneFalseNoneFalse776.440
232530968668NoneELECTRICAL SR CODE No 54.05Bentonite clay slurry for earthing in 50 Kg Bag ( Item No 54.05, SL No 393 ESCOMs SR 2023-24) ---- etc., complete with all leadBag447.27447.271.0FalseNoneNoneFalseNoneFalse447.270
232501568668None5.15GI Fish Plate (P.No.02/.I.No.45) BESCOM SR 2021 - 22 PART III ---- etc., complete with all leadNos105.02105.022.0FalseNoneNoneFalseNoneFalse210.040
232531068668NoneELECTRICAL SR CODE No 6.3.1Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required 25x3mm GI strip .(Item No 6.3.1 Electrical SR 2019-20) ---- etc., complete with all leadMtr91.1691.1612.0FalseNoneNoneFalseNoneFalse1093.920
232501668668None6.0611 kV, 5 kN Composite/Polymeric Pin Insulator (24 mm dia FRP Rod) (P.No.02/.I.No .51) BESCOM SR 2021 - 22 PART III ---- etc., complete with all leadNos241.9241.99.0FalseNoneNoneFalseNoneFalse2177.10
232531168668NoneELECTRICAL SR CODE No 32.051.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975. 16 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm) ( Item No 32.05, SL No 201 ESCOMs SR 2023-24) ---- etc., complete with all leadKm172394.77172394.770.2FalseNoneNoneFalseNoneFalse34478.9540
232501768668None6.078 Strain Insulator (P.No.02/.I.No .52) BESCOM SR 2021 - 22 PART III ---- etc., complete with all leadNos31.8631.868.0FalseNoneNoneFalseNoneFalse254.880
232531268668NoneELECTRICAL SR CODE No 21.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff. 2.5 to 25 Sqmm. ( Item No 21.05, SL No 174 ESCOMs SR 2023-24) ---- etc., complete with all leadKm25384.8425384.840.2FalseNoneNoneFalseNoneFalse5076.9680
232501868668None6.09DISC Insulator 45 kN Porcelain (P.No.02/.I.No .54) BESCOM SR 2021 - 22 PART III ---- etc., complete with all leadNos601.8601.86.0FalseNoneNoneFalseNoneFalse3610.80
232531368668NoneELECTRICAL SR CODE No 29.03Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr,Supplying and Displaying necessary Danger Boards and Lighting, Using sightRails and Sign Boards at every 100 Mtr wherever necessary as directed. In soil (hard) ( Item No 29.03 ESCOMs SR 2023-24) ---- etc., complete with all leadCum472.79472.7925.0FalseNoneNoneFalseNoneFalse11819.750
232501968668None7.02Rabbit ACSR (6/3.35 mm Al + 1/3.35 mm St), Std Wt: 214 Kg/KM (P.No.03/.I.No .61) BESCOM SR 2021 - 22 PART III ---- etc., complete with all leadKm54556.1254556.120.4FalseNoneNoneFalseNoneFalse21822.4480
232531468668NoneELECTRICAL SR CODE No 8.2.2Supplying and drawing PVC flexible one pair telepone unarmoured tinned copper cable. (91/11.2) 2 Pair ---- etc., complete with all leadMtr25.5225.521.0FalseNoneNoneFalseNoneFalse25.520
232502068668None8.017/10 SWG Guy Wire (7/3.251 mm Dia), Std Wt: 680 Kg/KM (P.No.03/.I.No .64) BESCOM SR 2021 - 22 PART III ---- etc., complete with all leadTonne91126.6891126.680.025FalseNoneNoneFalseNoneFalse2278.1670
232531568668NoneELECTRICAL SR CODE No 8.3Supplying and drawing PVC insulated gas injected physical foam jelly flooded co-axial TV cable.RG-6. ---- etc., complete with all leadRmtr53.4853.4815.0FalseNoneNoneFalseNoneFalse802.20
232502168668None8.028 SWG GI Wire (4.064 mm Dia), Std Wt: 125 Kg/KM ---- etc., complete with all leadTonne88547.288547.20.03FalseNoneNoneFalseNoneFalse2656.4160
232531668668NoneELECTRICAL SR CODE No 11.3.2Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI more than 80. Power Input: 220-240V @ 50/60Hz & Power factor more than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 w ---- etc., complete with all leadEach838.63838.6316.0FalseNoneNoneFalseNoneFalse13418.080
232502268668None12.04Distribution Transformer - 3 Phase, 11kV/433V - Stacked CRGO Core with Oil as per IS-1180 (Part-1): 2014 63 kVA, Aluminum Wdg, Star 2 (5 Star) (P.No.04/.I.No .105) BESCOM SR 2021 - 22 PART III ---- etc., complete with all leadNos215403.1215403.11.0FalseNoneNoneFalseNoneFalse215403.10
232531768668NoneELECTRICAL SR CODE No 11.5.2Supply of round/square recess/surface mounted rolling type LED Down light with .......W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI more than 80. Power Input: 220-240V @ 50/60Hz & Power factor more than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10-12W ---- etc., complete with all leadEach1075.631075.6316.0FalseNoneNoneFalseNoneFalse17210.080
232502368668None17.01LT Protection Kit (Dwg No. BESCOM/GM/QS&S/10 Dtd 24.11.2018) (P.No.05/.I.No .151) BESCOM SR 2021 - 22 PART III ---- etc., complete with all leadNos2387.142387.141.0FalseNoneNoneFalseNoneFalse2387.140
232531868668NoneELECTRICAL SR CODE No 11.11.3Supplying & fixing of retrofit type - LED bulb.......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI more than 70%. efficacy more than 80 lumen per watt, life more than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF more than 0.95, power loss should less than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7 W, 6500K ---- etc., complete with all leadEach181.09181.095.0FalseNoneNoneFalseNoneFalse905.450
232502468668None18.02LT Distribution Box for 100 kVA DTC with MCCB's (Sheet Metal) (Dwg No. BESCOM/GM/QS&S/58 Dtd 24.11.2018 (P.No.06/.I.No .152) BESCOM SR 2021 - 22 PART III ---- etc., complete with all leadNos26920.5226920.521.0FalseNoneNoneFalseNoneFalse26920.520
232531968668NoneELECTRICAL SR CODE No 11.11.5Supplying & fixing of retrofit type - LED bulb.......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI more than 70%. efficacy more than 80 lumen per watt, life more than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF more than 0.95, power loss should less than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 12 W, 6500K ---- etc., complete with all leadEach326.94326.942.0FalseNoneNoneFalseNoneFalse653.880
232502568668None19.019 kV, 5 kA Lightning Arrester Metal Oxide Ceramic type with GROUND DISCONNECTOR (Dwg No. BESCOM/GM/QS&S/26 Dtd 24.10.2007) (P.No.06/.I.No .152) BESCOM SR 2021 - 22 PART III ---- etc., complete with all leadSet1085.61085.61.0FalseNoneNoneFalseNoneFalse1085.60
232532068668NoneELECTRICAL SR CODE No 11.11.7Supplying & fixing of retrofit type - LED bulb.......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI more than 70%. efficacy more than 80 lumen per watt, life more than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF more than 0.95, power loss should less than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 18 W, 6500K ---- etc., complete with all leadEach517.76517.762.0FalseNoneNoneFalseNoneFalse1035.520
232502668668None20.0111 kV, HG Fuse Unit with Solid Core Insulator (Dwg No. BESCOM/GM/QS&S/21 Dtd 24.11.2018) (P.No.06/.I.No .157) BESCOM SR 2021 - 22 PART III ---- etc., complete with all leadSet1261.421261.421.0FalseNoneNoneFalseNoneFalse1261.420
232532168668NoneELECTRICAL SR CODE No 12.27Supplying & Fixing of Special Type pigmy and candle lamp. Operating voltage range from 180V to 265V, 50Hz AC power Supply ---- etc., complete with all leadNos63.263.22.0FalseNoneNoneFalseNoneFalse126.40
232502768668None21.01Double Pole TC Set for erection of Transformer on RCC/PSCC 9 Mtr Long Poles as per IS-1977 For 25/63/100 kVA 4/5 Star Rated Transformer on RCC Pole - 9 Mtr Long, 145 Kg WL - MS (P.No.06/.I.No .160) BESCOM SR 2021 - 22 PART III ---- etc., complete with all leadSet20725.5220725.521.0FalseNoneNoneFalseNoneFalse20725.520
232532268668NoneELECTRICAL SR CODE No 12.46Supplying & Fixing of 70-150 Watts lamp holder 2 Pin ---- etc., complete with all leadEach76.5776.579.0FalseNoneNoneFalseNoneFalse689.130
232502868668None24.0111 kV, 200 Amps Single Break GOS (Dwg No. BESCOM/GM/QS&S/23 Dtd 24.11.2018) (P.No.08/.I.No .184) BESCOM SR 2021 - 22 PART III ---- etc., complete with all leadSet11151.011151.01.0FalseNoneNoneFalseNoneFalse11151.00
232532368668NoneELECTRICAL SR CODE No 11.8.1Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT more than 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire more than IK08. Power Factor more than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency more than 130lm/w, nominal CRI more than 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 25watts ---- etc., complete with all leadNos2947.352947.352.0FalseNoneNoneFalseNoneFalse5894.70
232502968668None24.07H - Frame Set for fixing 11 kV, 200 Amps Single Break GOS - (For DP structure for providing New GOS for sectionalisation) - GI (P.No.08/.I.No .188) BESCOM SR 2021 - 22 PART III ---- etc., complete with all leadSet7163.787163.781.0FalseNoneNoneFalseNoneFalse7163.780
232532468668NoneELECTRICAL SR CODE No 6.1Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. ---- etc., complete with all leadEach1813.381813.383.0FalseNoneNoneFalseNoneFalse5440.140
232503068668None24.1Insulated GOS Operating Rods (P.No.08/.I.No .191) BESCOM SR 2021 - 22 PART III ---- etc., complete with all leadNos487.34487.341.0FalseNoneNoneFalseNoneFalse487.340
232532568668NoneELECTRICAL SR CODE No 6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm) Regular model ---- etc., complete with all leadEach3626.753626.756.0FalseNoneNoneFalseNoneFalse21760.50
232503168668None25.0211 kV, DOLO Cutout REC Specification (Dwg No. BESCOM/GM/QS&S/20 Dtd 24.11.2018) (P.No.08/.I.No .193) BESCOM SR 2021 - 22 PART III ---- etc., complete with all leadSet5004.385004.381.0FalseNoneNoneFalseNoneFalse5004.380
232532668668NoneELECTRICAL SR CODE No 13.7.1Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders ---- etc., complete with all leadEach148.28148.2820.0FalseNoneNoneFalseNoneFalse2965.60
232503268668None194DP Set (2 Pole Strucrure Kit) as per IS-1977 For RCC Pole - 9 Mtr Long, 145KG WL/PSCC Pole - 9 Mtr Long, 300Kg WL - MS (Dwg No. BESCOM/GM/QS&S/35 & 63 Dtd 24.11.2018) (P.No.08/.I.No .194) BESCOM SR 2021 - 22 PART III ---- etc., complete with all leadSet7553.187553.181.0FalseNoneNoneFalseNoneFalse7553.180
232532768668NoneELECTRICAL SR CODE No 13.10.Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. ---- etc., complete with all leadEach207.83207.836.0FalseNoneNoneFalseNoneFalse1246.980
232503368668None32.051.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 (P.No.09/.I.No .32) BESCOM SR 2021 - 22 PART III 16 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm) (P.No.09/.I.No .215) BESCOM SR 2021 - 22 PART III ---- etc., complete with all leadKm167373.56167373.560.12FalseNoneNoneFalseNoneFalse20084.82720
232532868668NoneELECTRICAL SR CODE No 13.13Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. ---- etc., complete with all leadEach859.29859.293.0FalseNoneNoneFalseNoneFalse2577.870
232503468668None32.071.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 (P.No.09/.I.No .32) BESCOM SR 2021 - 22 PART III 35 Sqmm, 3.5 Core, (14 GI Strips - 4 x 0.8 mm) (P.No.09/.I.No .219) BESCOM SR 2021 - 22 PART III ---- etc., complete with all leadKm212215.92212215.920.2FalseNoneNoneFalseNoneFalse42443.1840
232532968668NoneELECTRICAL SR CODE No 13.4.1Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. Length ---- etc., complete with all leadEach1775.71775.72.0FalseNoneNoneFalseNoneFalse3551.40
232503568668None52.01Transparent Alkathine tube 19 mm dia, 2 mm thick in coils of 30 Mtr (P.No.17/.I.No .444) BESCOM SR 2021 - 22 PART III ---- etc., complete with all leadCoil610.06610.061.0FalseNoneNoneFalseNoneFalse610.060
232533068668NoneELECTRICAL SR CODE No 13.5Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. ---- etc., complete with all leadEach196.89196.892.0FalseNoneNoneFalseNoneFalse393.780
232503668668None53.04LT 3 Phase, 4 Wire, CT Operated DLMS Complaint ETV Meter-5A, class 0.5s Accuracy (Used for 25 HP/18KW & Above Installations, DTC Metering (P.No.18/.I.No .451) BESCOM SR 2021 - 22 PART III ---- etc., complete with all leadNos2808.42808.41.0FalseNoneNoneFalseNoneFalse2808.40
232533168668NoneELECTRICAL SR CODE No 5.42.2Fabricating supplying and mounting MS box made out....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 16SWG ---- etc., complete with all leadSq CM0.520.5240000.0FalseNoneNoneFalseNoneFalse20800.00
232503768668None5.37Supplying .fixing and wiring heavy duty low voltage capacitors conforming to IS 2834, 3 phase, 400/440 volts grade, for power factor improvement of rotating machinerieslike induction motor.(P.No14/.I.No.5.37) ---- etc., complete with all leadKvar566.4566.45.0FalseNoneNoneFalseNoneFalse2832.00
232533268668NoneELECTRICAL SR CODE No 5.40.1Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 100Amps 4x30x6mm Aluminum Strips ---- etc., complete with all leadMtr2995.962995.963.0FalseNoneNoneFalseNoneFalse8987.880
232503868668None21.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff (P.No.09/ .I.No.31.06/) BESCOM SR 20211-22 PART IV 2.5 to 25 Sqmm ---- etc., complete with all leadKm24645.4824645.480.12FalseNoneNoneFalseNoneFalse2957.45760
232533368668NoneELECTRICAL SR CODE No 5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- etc., complete with all leadMtr370.7370.72.0FalseNoneNoneFalseNoneFalse741.40
232503968668None21.06Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff (P.No.09/ .I.No.31.06/) BESCOM SR 20211-22 PART IV 35 sqmm to 95 sqmm ---- etc., complete with all leadKm27903.4627903.460.2FalseNoneNoneFalseNoneFalse5580.6920
232533468668NoneELECTRICAL SR CODE No 5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., complete with all leadMtr918.84918.842.0FalseNoneNoneFalseNoneFalse1837.680
232504068668None74aSupplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes ( (P.No.43/ .I.No.6.17)PWD ELECTRICAL SR 2019-20 1.5 sqmm ---- etc., complete with all leadEach3.543.5432.0FalseNoneNoneFalseNoneFalse113.280
232533568668NoneELECTRICAL SR CODE No 5.15.9Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR POLE 100 A 25 kA ---- etc., complete with all leadEach10315.110315.11.0FalseNoneNoneFalseNoneFalse10315.10
232504168668None74bSupplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes ( (P.No.43/ .I.No.6.17)PWD ELECTRICAL SR 2019-20 6 sqmm ---- etc., complete with all leadEach8.268.2640.0FalseNoneNoneFalseNoneFalse330.40
232533668668NoneELECTRICAL SR CODE No 5.18.8Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 40 A TPN ---- etc., complete with all leadEach3699.683699.681.0FalseNoneNoneFalseNoneFalse3699.680
232504268668None74cSupplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes ( (P.No.43/ .I.No.6.17)PWD ELECTRICAL SR 2019-20 35 sqmm long barrel ---- etc., complete with all leadEach37.7637.7632.0FalseNoneNoneFalseNoneFalse1208.320
232533768668NoneELECTRICAL SR CODE No 5.18.4Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32A DP ---- etc., complete with all leadEach898.18898.184.0FalseNoneNoneFalseNoneFalse3592.720
232504368668None11.2.5 V-5Providing, Laying and Fixing GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing). (P.No.142/ .I.No.1/2.5) WS&UGD works SR 2022 For Medium Duty GI pipe: 40mm dia ---- etc., complete with all leadRmtr575.84575.8412.0FalseNoneNoneFalseNoneFalse6910.080
232533868668NoneELECTRICAL SR CODE No 5.7.2Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers 32 A ---- etc., complete with all leadEach292.91292.914.0FalseNoneNoneFalseNoneFalse1171.640
232504468668None13.39 V-5Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia. (P.No.164/.I.No. P430A) WS&UGD works SR 2022 ---- etc., complete with all leadJob4425.04425.012.0FalseNoneNoneFalseNoneFalse53100.00
232533968668NoneELECTRICAL SR CODE No 5.7.3Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers 63 A ---- etc., complete with all leadEach487.38487.381.0FalseNoneNoneFalseNoneFalse487.380
232504568668None12.58.1Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required.(P.No.40/.I.No.6.3) PWD Electrical SR 2019-20 25x3mm Gl strip ---- etc., complete with all leadMtr96.7696.7630.0FalseNoneNoneFalseNoneFalse2902.80
232534068668NoneELECTRICAL SR CODE No 5.3Supplying, fixing and wiring electronic 5 to 20Amps single phase Class-1 Accuracy with Temper Proof Energy Meter ---- etc., complete with all leadEach1677.251677.253.0FalseNoneNoneFalseNoneFalse5031.750
232504668668None12.58.11Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required.(P.No.40/.I.No.6.3) PWD Electrical SR 2019-20 600x600x3mm Copper plate ---- etc., complete with all leadEach8756.788756.781.0FalseNoneNoneFalseNoneFalse8756.780
232534168668NoneELECTRICAL SR CODE No 5.33Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy ---- etc., complete with all leadEach11321.4511321.451.0FalseNoneNoneFalseNoneFalse11321.450
232504768668None1.1.2Digging of Pit 1.8 Mtr depth for errection of 9 to 10 Mtr Long Steel/RCC/PSCC supports as per approved Drawing. (P.No.01/.I.No .1.1) BESCOM SR 2021 - 22 PART IV Hard Soil ---- etc., complete with all leadPer Pit1335.761335.765.0FalseNoneNoneFalseNoneFalse6678.80
232534268668NoneELECTRICAL SR CODE No 5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., complete with all leadEach625.93625.933.0FalseNoneNoneFalseNoneFalse1877.790
232504868668None1.7.2Digging of Pit for GUY SET. (P.No.01/.I.No .1.7) BESCOM SR 2021 - 22 PART IV Hard Soil ---- etc., complete with all leadPer Pit742.22742.222.0FalseNoneNoneFalseNoneFalse1484.440
232534368668NoneELECTRICAL SR CODE No 5.34Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound ---- etc., complete with all leadEach683.05683.053.0FalseNoneNoneFalseNoneFalse2049.150
232504968668None1.8aProviding cement concrete to Poles and Guy sets with material and labour including necessary curing etc., complete (cost doesnot include excavation) (P.No.01/.I.No .1.8) BESCOM SR 2021 - 22 PART IV Base Concreting with CC 1:4: 8 Pole base for 11/9.5/9/8 Mtr supports (500x650x150mm) ---- etc., complete with all leadEach322.14322.145.0FalseNoneNoneFalseNoneFalse1610.70
232534468668NoneELECTRICAL SR CODE No 7.1.3Supplying ...litres capacity vertical/horizontal type wall mounting Electrical water heater with 22 SWG copper/SS sheet metal inner Container tinned inside and anticorrosive paint outside and 20 SWG M.S. sheet metal outer cover filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate .2KW capacity element with a neon indicator fitted with 20A capacity 25 to 85 degree Centigrade range thermostat. The water heater shall completely be wired with 40/0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting. 25Litres ---- etc., complete with all leadEach12448.1312448.132.0FalseNoneNoneFalseNoneFalse24896.260
232505068668None1.8bPole Concreting with CC 1:2:4 (without coping) 9 Mtr support (650x500x1700mm) ---- etc., complete with all leadEach3726.443726.445.0FalseNoneNoneFalseNoneFalse18632.20
232534568668NoneELECTRICAL SR CODE No 7.3.2Supplying, installation, testing and commissioning of solar hot water heater comprising of solar Flat Plate Collector (FPC) of size 2120x1040x100mm and stainless steel hot water storage tank with stainless steel heat exchanger absorber made of copper sheet and copper tube of following capacity aluminium box collector with appropriate capacity electrical back up arrangement excluding inlet and out let pipes. SS Model with 100mm thick of 48Kg/M3density Rock wool insulation with 22SWG Aluminium cladding. 200 L Capacity ---- etc., complete with all leadEach57019.2857019.282.0FalseNoneNoneFalseNoneFalse114038.560
232505168668None2.02Erection of RCC/PSCC Pole of 9 to 10 Mtr long in a pit of 1.8 Mtr depth(P.No.02/.I.No .2.02) BESCOM SR 2021 - 22 PART IV ---- etc., complete with all leadEach1313.341313.345.0FalseNoneNoneFalseNoneFalse6566.70
232505268668None3.01Erection of Double Pole Transformer Structure using 9 Mtr Long RCC (145 Kg WL)/PSCC (300 Kg WL) Pole including fixing of Structure Materials, Erection of Poles etc., complete for mounting of Transformer as per approved drawing For 25/63/100 kVA (P.No.02/.I.No .3.01) BESCOM SR 2021 - 22 PART IV ---- etc., complete with all leadPer Structure6755.56755.51.0FalseNoneNoneFalseNoneFalse6755.50
232505368668None2.09Erection of H-Frame. (P.No.02/.I.No .2.09) BESCOM SR 2021 - 22 PART IV ---- etc., complete with all leadEach381.14381.141.0FalseNoneNoneFalseNoneFalse381.140
232505468668None5.02Fixing of 4 Pin cross arm with Insulator and Braces fixing(P.No.02/.I.No .5.02) BESCOM SR 2021 - 22 PART IV ---- etc., complete with all leadEach188.8188.82.0FalseNoneNoneFalseNoneFalse377.60
232505568668None5.03Fixing of V-Shape/Horizontal cross arm including Single Top Support Brace and Insulator fixing (P.No.02/.I.No .5.03) BESCOM SR 2021 - 22 PART IV ---- etc., complete with all leadEach188.8188.85.0FalseNoneNoneFalseNoneFalse944.00
232505668668None5.10Fixing of GUY Set with break insulator making use of 7/3.15 mm (7/10 SWG) galvanised steel wire with turn buckle and anchoring arrangement as per approved drawing. (Excluding excavation of PIT)(P.No.02/.I.No .5.10) BESCOM SR 2021 - 22 PART IV ---- etc., complete with all leadEach313.88313.882.0FalseNoneNoneFalseNoneFalse627.760
232505768668None6.02Stringing of conductor Rabbit ACSR, binding of conductor on each insulator and dead ending on strain or disc/strain insulator by means of clamps.(P.No.03/.I.No .5.70) BESCOM SR 2021 - 22 PART IV ---- etc., complete with all leadPer Km3752.43752.40.4FalseNoneNoneFalseNoneFalse1500.960
232505868668None8.01Erection of 25 to 63 kVA Transformer on Transformer Structure .(P.No.03/.I.No .7.01) BESCOM SR 2021 - 22 PART IV ---- etc., complete with all leadEach1407.741407.741.0FalseNoneNoneFalseNoneFalse1407.740
232505968668None11.01Fixing Metering Box for housing the ETV Meter 3 Phase 4 Wire along with CT's, Meter & wiring for DTC 25/63 kVA TC (P.No.04/.I.No .11.01) BESCOM SR 2021 - 22 PART IV ---- etc., complete with all leadSet2296.282296.281.0FalseNoneNoneFalseNoneFalse2296.280
232506068668None13.01Fixing DOLO Cutout/Horn Gap Fuse including fixing of cross arm and wiring(P.No.05/.I.No .13.01) BESCOM SR 2021 - 22 PART IV ---- etc., complete with all leadEach279.66279.663.0FalseNoneNoneFalseNoneFalse838.980
232506168668None13.02Fixing of GOS including wiring (11 kV Single Break 200 Amps) (P.No.05/.I.No .13.02) BESCOM SR 2021 - 22 PART IV ---- etc., complete with all leadEach1302.721302.721.0FalseNoneNoneFalseNoneFalse1302.720
232506268668None13.06Fixing of 3 Nos Lightning Arrestor including wiring (P.No.05/.I.No .13.07) BESCOM SR 2021 - 22 PART IV ---- etc., complete with all leadSet106.2106.21.0FalseNoneNoneFalseNoneFalse106.20
232506368668None15.04Wiring of 1 Circuit of LT Wiring for for 25/63/100 kVA DTC to the existing LT protection Kit/Distribution Box via metering box. (includes fixing of necessary supports like 2 Pin cross arm, Spacer etc) (P.No.06/.I.No .15.04) BESCOM SR 2021 - 22 PART IV ---- etc., complete with all leadSet848.42848.421.0FalseNoneNoneFalseNoneFalse848.420
232506468668None29.01Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr, Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed. (P.No.08/.I.No .29.03) BESCOM SR 2021 - 22 PART IV in Hard soil ---- etc., complete with all leadCum459.02459.0225.0FalseNoneNoneFalseNoneFalse11475.50
232506568668None29.07Refilling the cable trenches with selected available earth from trench excavation including watering, consolidation in layers of 15 cm. Thickness including depositing of the surplus earth with a lead of 200 Mtr (P.No.08/.I.No .29.07) BESCOM SR 2021 - 22 PART IV in Hard soil ---- etc., complete with all leadCum68.4468.4425.0FalseNoneNoneFalseNoneFalse1711.00
232506668668None10.1Supplying, installing, testing and commissioning of Diesel Generator set with following specifications. Power rating as per standard reference condition as per-BS 5514/ISO 3046/ ISO 8528 & IS 1002/ISO 3046 Generator set specifications. Engine: Diesel generating set are rated at 1500RPM and conform to ISO 8528 specifications. The engines are radiator cooled, four stroke and multi cylinder, conforming to ISO 3046. The scope of supply includes: Electrical starter motor12V DC Battery charging alternator, Bosch fuel system with mechanical governor, A1 Class. Spin-on lube oil filter, Spin-on dual fuel filter with water separator, Turbocharger, Charge air cooler, Silencer (Hospital grade), Dry type air cleaner, Shutoff coil, Flywheel and flywheel housing, First fill of lube oil and coolant, Safety for low lube oil pressure, Safety for high water temperature, Permissible overload of 10% for one hour in 12 hours of operation Capacity of Fuel Tank: Fuel tank suitable for 8 hours of operation Alternator: Alternator is suitable for operation at 1500 RPM, 415 Volts, 0.8 pf (lag) suitable for 50 Hz, 3 phase, 4 wire systems, conforming to IS/IEC 60034-1. The Alternator is brush less type, screen protected, revolving field, self excited, self regulated through an AVR. The alternator shall have plus or minus 1.0% Voltage regulation (max) in static conditions- IP: 23 protections with insulation class F&H. Mounting arrangement: Engine and alternator are mounted on a common MS fabricated base frame with AVM pads. Control Panel: The control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish. The control panel consists of the following parts:- PS0500 Controller, Aluminium bus bars with suitable capacity within/outgoing terminals, Indicating lamps for 'Load On' and 'Set Running', Instrument fuses duly wired and ferruled, MCCB of suitable rating with overload and short circuit protections. Genset Controller: microprocessor based generator set monitoring and control system. The control provides a simple operator interface to the generator set, manual and remote start/ stop control, shutdown fault indication, and an LCD hour counter. The integration of all functions into a single control system provides enhanced reliability and performance compared to conventional generator set control systems. This control has been designed and tested to meet harsh environment in which gensets are typically applied. Features, Functions, protections 16 character x 2 line alphanumeric LCD display with LED Backlight Operator interface, Provide a record of most recent fault conditions. Fault history stored in the control non volatile memory, Provide Alternator Data. Voltage (1 ph or 3 ph line to line and line to neutral voltage, Current (1 ph or 3 ph), kVA (3 ph and total), Frequency, Provide Engine Data, Starting battery voltage, Engine running hours, Engine Temp, Engine oil pressure, Control includes provision for Service adjustment and calibration of DG control functions, Voltage, frequency selection, Configurable input and output set up, Meter calibration, Engine controls, Power Start operates on 12 VDC batteries,-Auto start mode accepts a ground signal from remote devices to automatically start the DG set The remote start will also wake up the control system from sleep mode. Engine Starting -The control system supports automatic engine starting, Primary and back up start disconnects are achieved by battery charging alternator feedback or main alternator output frequency. Controller provide configurable time delay of 0-300 sees to start after remote start signal and time delay of 0-600secs prior to shut down after stop signal. Sleep mode increase battery life. : etc., : 25 KVA/20kw ---- etc., complete with all leadSet532299.18532299.181.0FalseNoneNoneFalseNoneFalse532299.180
232506768668None7.4.3Supplying, installation, testing and commissioning of solar hot water heater comprising of high quality Evacuated Glass Tube (EGT) with absorber coating collector of size 58 x 1800 mm. Inner tank Material-Stainless steel 304-L Grade with Aluminium Stucco cladding made of High quality PUF insulation to minimizes heat loss and hold water Temperature upto 72 Hrs...with appropriate capacity electrical back up arrangement excluding inlet and out let pipes. Fitted with Sacrificial Anode (P.No.27/.I.No.7.4) PWD Electrical SR 22-23 300 Liter capacity- 29 nos Tubes ---- etc., complete with all leadEach60803.0460803.041.0FalseNoneNoneFalseNoneFalse60803.040
232506868668None9.2.5Supplying,erecting,testing&commissioningofOFF-LINEUPSsystemsuitableforoperationon230V,50Hz,A/Csupply,withallaccessories complete and Excluding batteries and wiring complete. 5 kVA OFF LINE UPS ---- etc., complete with all leadEach47079.6447079.641.0FalseNoneNoneFalseNoneFalse47079.640
232506968668None6.7.2Supplying......TRsplitAirconditionerssuitableforoperationonA/Csupplysinglephase50Hz230Vwithhermeticallysealedcompressorwithaircooledcondenser,motorcapacitorandstartruncapacitors,relayandoverloadprotectorinternalunit,withoneindoorandoneoutdoorunitThecondenserunitwillbeplacedoutsidetheroomontheterracetoavoidnoiseincludingstandardlengthofsuitablesizecoppertubingcoveredwithinsulationtube.(Highwallchorded/cordless)suitablecapacity3coresheathed/PVCcoppercable and a battery operated wireless remote unit 1.5 Ton capacity ---- etc., complete with all leadEach56265.9456265.942.0FalseNoneNoneFalseNoneFalse112531.880
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17065135980000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17065135980001NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of KarnatakaNone
17065135980001NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of Karnataka public Procurement on or before the last date and time of bid submission.None
17065136500000NoneNoneELIGIBILITYThe bidder is required to ensure browser compatibility of the computer well in advance to the last date and time for receipt of tenders. The departments shall not be responsible for non-accessibility of Karnataka public Procurement portal due to internet connectivity issues and technical glitches at bidders end.None
17065136590000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejectionNone
17065136690000NoneNoneELIGIBILITYBidder shall pay Contract Management Module processing fees of 0.025% of the contact value (Min Rs.500/- & Max Rs.7500/-) soon after contract has been issued to bidder.None
17065136780000NoneNoneELIGIBILITYThe tenderer shall bear all costs associated with the preparation and submission of his tender, and the employer will in no case be responsible and liable for those costsNone
17065136870000NoneNoneELIGIBILITYConditional tenders will not be accepted.None
17065136980000NoneNoneELIGIBILITYAll the formats prescribed in the bid document shall be filled by the tenderer in complete manner.None
17065137060000NoneNoneELIGIBILITYRoyalty on construction materials and other taxes will be deducted as per prevailing Govt., orders as may be modified from time to time.None
17065137150000NoneNoneELIGIBILITYAny discrepancies observed in the documents uploaded by the tenderer the tender shall liable to rejected.None
17065137270000NoneNoneELIGIBILITYEarnest Money Deposit will have to be in any one of the forms as per the instructions in the financial bid document and shall have to be valid for 45 days beyond the validity of the tender.None
17065137410000NoneNoneELIGIBILITYAll formats prescribed in the bid documents shall be filled in complete manner (section 2 & of the bid document)and shall be uploaded properly, signed by tenderer. Necessary certificates shall be uploaded along with the formats wherever required. General documents section can be used for this purpose.None
17065137510000NoneNoneELIGIBILITYTenderers are required to read the Bid Documents carefully before submission of their bidNone
17065137620000NoneNoneELIGIBILITYIf the tenderer quotes bid price below the estimated contract value (Amount put to tender) then the tenderer has to submit the additional security deposit equal to the difference in cost and the additional security deposit should have a validity for the period of execution.None
17065137720000NoneNoneELIGIBILITYIf the numbers of page to be attached in one particular attachment is more, then all the pages can be put into one folder, zipped and then attached or else all the pages can be pasted in one word file and then this word file could be converted to PDF (portable documents format) format and then attached. (Please contract help desk from 9.00 AM to 9.00 PM ( Monday to Saturday) Ph No: 91-8046010000 and 91-8068948777 or send query through Karnataka public procurement portal through query option on or before specified time.None
17065137830000NoneNoneELIGIBILITYThe Contractor shall strictly take all reasonable steps to protect the environment on and off the site and to avoid damage or nuisance to persons or to property of the public or others resulting from pollution, noise or other causes arising as a consequence of his methods of operation.None
17065137920000NoneNoneELIGIBILITYMaterials like, steel (primary), cement, bitumen etc., required for the work shall be procured by the tenderer themselves and should be got tested positive by the quality control authority before use on the work.None
17065138020000NoneNoneELIGIBILITYTenderer should have latest GST Registration and latest clearance certificate in their nameNone
17065138120000NoneNoneELIGIBILITYThe Rates quoted by the tenderer shall be inclusive of GST.None
17065138220000NoneNoneELIGIBILITYSpecial Instructions to tenderers - as per bid document.None
17065138310000NoneNoneELIGIBILITYThe Defects Liability Period is 1 year from the date of completion of the work.None
17065138500000NoneNoneELIGIBILITYTotal value of Civil Engineering Construction works executed in the and payments received in the last five year i.e., 2018-19, 2019-20, 2020-21 2021-22 & 2023-24.None
17065138630000NoneNoneELIGIBILITYThe Tenderers are bound to furnish the original certified documents to the employer within 3 days from the day of opening of technical bid for verification, failing which the bid of tenderer will be considered as technically non responsive.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneClause ITT 3.2(b)To qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2018-19 to 2022-23) The tenderer should have been Satisfactorily completed at least one Satisfactorily completed at least one Similar work of value not less than Rs.296.00 Lakhs as prime contractor. Note : The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (b).Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause 3.2(c) To qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2018-19 to 2022-23). Executed in any one year, the following minimum quantities of work Sl. No Description of key items of works Quantity 1)Earthwork Excavation 3601.00 Cum,2)RCC and PCC 1013.00 Cum 3)Steel Reinforcement for RCC work 46.00 Tonnes 4)Cement concrete Block Masonry/Solid Block Masonry 2015.00 Sqm 5)Flooring / Dadooing (Vitrified/ Granite/ Ceramic/ Cement concrete/cladding/ dadooing)1782.00 Sqm,6)Plastering 7268.00 Sqm,7)Painting 6767.00 SqmPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause 3.2(d) The tenderer or his identified sub contractor should possess required valid electrical license for executing building electrification works issued by KPWD/ Government electrical Inspectorate and should have executed similar Building electrical works totaling Rs.23.00 Lakhs in any one yearPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause 3.2(e)The Tenderer or his identified sub-contractor should possess valid license for executing water supply/sanitary engineering works issued by BWSSB/ KUWS&DB and should have executed similar building water supply/sanitary engineering works totaling Rs.19.50 Lakhs in any one yearPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause ITT 3.3 (a)Equipment capacity Each tenderer should further demonstrate(a) available by owning at least 50% of the required/specified key and critical equipment for this work and (b) the remaining 50% can be deployed on ease/hire basis for all works provided, the relevant documents (commitment agreements etc.,) for availability for this work are furnished. Sl.No. Description of Equipment Quantity 1 Min 10 cft capacity Concrete Mixer-2 Nos.2.Steel Centering and shuttering sheets-1000 sqmtr 3.Tipper-2 Nos 4.Excavator-1 No.5.Water tanker-1 No 6.Bar, Bending and cutting machine 1 No.7.Generator 500 KVA 1 No.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Others -- Tax Invoice/ Agreements from the supplier
NoneNoneNoneNoneKPWD Class-I Registration CertificateCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneClause 3.6 Tenderers who meet the above specified minimum qualifying criteria, will only be qualified, if their available tender capacity is more than the total tender value. The available tender capacity will be calculated for prime contractor are as under Assessed available tender capacity AxNx1.5- B Where A maximum value of civil engineering works executed in any one year during the last five years 2018-19 to 2022-23 updated to 2023-24 price level taking into account the completed as well as works in progress. N Number of years prescribed for completion of the works for which tenders are invited. B Value, at 2023 24 price level of existing commitments and ongoing works to be completed during the next 09 months. Note The statements showing the value of existing commitments and on-going works as well as the stipulated period of completion remaining for each of the works listed should be countersigned by the Employer in charge, not below the rank of an Executive Engineer or equivalent.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Certificate issued by the officer not lessthan the rank of Executive Engineer Ongoing commitments and Bids submitted for the works
NoneNoneNoneNoneList of Minimum Key Personnel to be deployed by the contractor at site for Contract work Sl No Position Qualification and Requirement No Of Persons 1Project Manager BE Civil with minimum experience of 15 years in the Construction of buildings 1 One. 2)Site Engineer BE Civil with minimum experience of 7 years in the Construction of buildings Or Diploma in Civil Engineering with minimum experience of 10 years in the Construction of buildings and should have been working in permanent role of the organization for at least two years 2 Two 3)Electrical Engineer BE Electrical with minimum experience of 5 years in the Construction of buildings Or Diploma in Electrical Engineering with minimum experience of 10 years in the Construction of buildings and should have been working inpermanent role of the organization for at least two years 2 Two.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Personel Experience Certificate, Degree certificates with the CVs
NoneNoneNoneNoneClause ITT 3.2(a):The tenderer should have been achieved in at least two financial years a minimum annual financial turnover (in all classes of civil Engineering construction works only) of Rs.1576.00 Lakhs.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneClause 3.3(b)Liquid assets and /or availability of credit facilities of not less than Rs.178.00 Lakhs (Credit lines / letter of credit/ certificates from banks for meeting the fund requirement etc.(As per the prescribed format in clause 1.10 of SECTION 3, QUALIFICATION INFORMATION of this document.) as prime Contractor.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Others -- Certificate issued by a Scheduled/ Nationalised Bank
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
Company Registration CertificateTrueTechnical Bid
ESI and PF Certificates and paid challansTrueTechnical Bid
GST Registration and latest paid receipts.TrueTechnical Bid
Workdone CertificateTrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1706515530000
version0
createdDateNone
modifiedDateNone
blockNumberOffice of the Chief Engineer, Engineering Wing, HFWD, Arogya Soudha, 3rd Floor, 1st Cross Magadi Road
streetNone
cityBengaluru
stateKarnataka
pin560023
tenderRecallDTONone