| 2315825 | 68320 | None | 1.15.1 V-I | Earth work excavation for Foundation by mechanical means for allworks& depth upto 3 m, as per drawing and technicalspecifications,including setting out,shoring, strutting, barricading, caution lights,including dressing of excavated surfaces, disposing off or levelling theexcavated earth or sorting & stacking the selected earth for reuse in aradius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery &other appurtenaces required to complete the work In ordinary/softrock without blasting upto1.5m depth With all lead and lifts as per the direction of engineer incharge | Cum | 381.15 | 381.15 | 39.72 | False | None | None | False | None | False | 15139.278 | 0 |
| 2315826 | 68320 | None | 1.23 V-I | Providing Filling in foundation with granite/ trap broken metal 100mm and down size with approved sand including hand packing, ramming, watering including cost of all materials and labour with lead up to 50m and lift of 1.5m complete as per specifications.With all lead and lifts as per the direction of engineer incharge | Cum | 2816.1 | 2816.1 | 11.72 | False | None | None | False | None | False | 33004.692 | 0 |
| 2315827 | 68320 | None | 2.1.2 V-I | Providing and laying in position plain cement concrete for levellingcourse for all works in foundation. Thegranite/trap/basaltcrushedgraded coarse aggregatesand fine aggregatesas per relevant IS Codes machine mixed, laid in layers not exceeding150mm thickness, well compacted using plate vibrators, including all lead & lifts,cost of all materials of quality, labour, Usage charges of machineries, curing,and all the other appurtenances required to complete the work as pertechnical specifications. (The cost of steel reinforcement & formworkshallbepaidseparately) Mix1:4:8 (M5) Using 40mm nominal size graded crushed coarse aggregates With all lead and lifts as per the direction of engineer incharge | Cum | 5947.2 | 5947.2 | 9.51 | False | None | None | False | None | False | 56557.872 | 0 |
| 2315828 | 68320 | None | 2.2.1 V-I | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates With all lead and lifts as per the direction of engineer incharge | Cum | 7104.31 | 7104.31 | 4.54 | False | None | None | False | None | False | 32253.5674 | 0 |
| 2315829 | 68320 | None | 2.2.1 V-I | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates With all lead and lifts as per the direction of engineer incharge | Cum | 11002.25 | 11002.25 | 0.44 | False | None | None | False | None | False | 4840.99 | 0 |
| 2315830 | 68320 | None | 5.4 V-II | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) With all lead and lifts as per the direction of engineer incharge | Cum | 6708.45 | 6708.45 | 6.57 | False | None | None | False | None | False | 44074.5165 | 0 |
| 2315831 | 68320 | None | 2.3.1 V-I | Providing and laying in Reinforced cement concretefor all Basement & surface level works, return walls, retaining walls, sunken floors etc. Thegranite /trap/ basalt crushed graded coarse aggregates and fine aggregatesas per relevant IS Codes machine mixed with superplasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts,costof all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formworktobepaidseparately) M20 Design Mix Using 20mm nominal size graded crushed coarse aggregates.With all lead and lifts as per the direction of engineer incharge | Cum | 9800.65 | 9800.65 | 1.68 | False | None | None | False | None | False | 16465.092 | 0 |
| 2315832 | 68320 | None | 2.5.1 V-I | Providing and laying in position Reinforced cement concretefor all Super structures of building,Roadworks,Waterworks,Irrigationworks& super structure works of bridgesupto 3.50 m height. Thegranite/trap/basaltcrushed graded coarse aggregatesand fine aggregatesas per relevant IS Codes machine mixed with super plasticisers laid inlayers, well compacted using needlevibrators. The cost includes alllead & lifts, cost of all materials, quality confirming to the requirementsof relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement,dowel bars & formwork to be paid separately) M20 Design Mix Using 20mm nominal size graded crushed coarse aggregatesWith all lead and lifts as per the direction of engineer incharge | Cum | 11602.5 | 11602.5 | 2.11 | False | None | None | False | None | False | 24481.275 | 0 |
| 2315833 | 68320 | None | 2.5.1 V-I | Providing and laying in position Reinforced cement concretefor all Super structures of building,Roadworks,Waterworks,Irrigationworks& super structure works of bridgesupto 3.50 m height. Thegranite/trap/basaltcrushed graded coarse aggregatesand fine aggregatesas per relevant IS Codes machine mixed with super plasticisers laid inlayers, well compacted using needlevibrators. The cost includes alllead & lifts, cost of all materials, quality confirming to the requirementsof relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement,dowel bars & formwork to be paid separately) M20 Design Mix Using 20mm nominal size graded crushed coarse aggregatesWith all lead and lifts as per the direction of engineer incharge | Cum | 9945.0 | 9945.0 | 0.14 | False | None | None | False | None | False | 1392.3 | 0 |
| 2315834 | 68320 | None | 2.5.1 V-I | Providing and laying in position Reinforced cement concretefor all Super structures of building,Roadworks,Waterworks,Irrigationworks& super structure works of bridgesupto 3.50 m height. Thegranite/trap/basaltcrushed graded coarse aggregatesand fine aggregatesas per relevant IS Codes machine mixed with super plasticisers laid inlayers, well compacted using needlevibrators. The cost includes alllead & lifts, cost of all materials, quality confirming to the requirementsof relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement,dowel bars & formwork to be paid separately) M20 Design Mix Using 20mm nominal size graded crushed coarse aggregatesWith all lead and lifts as per the direction of engineer incharge | Cum | 10939.5 | 10939.5 | 4.16 | False | None | None | False | None | False | 45508.32 | 0 |
| 2315835 | 68320 | None | 2.5.1 V-I | Providing and laying in position Reinforced cement concretefor all Super structures of building,Roadworks,Waterworks,Irrigationworks& super structure works of bridgesupto 3.50 m height. Thegranite/trap/basaltcrushed graded coarse aggregatesand fine aggregatesas per relevant IS Codes machine mixed with super plasticisers laid inlayers, well compacted using needlevibrators. The cost includes alllead & lifts, cost of all materials, quality confirming to the requirementsof relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement,dowel bars & formwork to be paid separately) M20 Design Mix Using 20mm nominal size graded crushed coarse aggregates | Cum | 10276.5 | 10276.5 | 7.62 | False | None | None | False | None | False | 78306.93 | 0 |
| 2315836 | 68320 | None | 1.9 V-I | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming andwatering,leadupto 50m andliftupto1.5m. With all lead and lifts as per the direction of engineer incharge | Cum | 279.3 | 279.3 | 40.95 | False | None | None | False | None | False | 11437.335 | 0 |
| 2315837 | 68320 | None | 6.33 V-II | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specification | Sqm | 1292.55 | 1292.55 | 61.71 | False | None | None | False | None | False | 79763.2605 | 0 |
| 2315838 | 68320 | None | 2.11 V-I | Providing Thermo-Mechanically Treated bars of grade Fe-550 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) | Kg | 93929.9 | 93929.9 | 2.1545 | False | None | None | False | None | False | 202371.96955 | 0 |
| 2315839 | 68320 | None | 11.5.1 V-II | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.With all lead and lifts as per the direction of engineer incharge | Sqm | 4701.9 | 4701.9 | 2.52 | False | None | None | False | None | False | 11848.788 | 0 |
| 2315840 | 68320 | None | 11.11.1 V-II | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.With all lead and lifts as per the direction of engineer incharge | Kg | 155.4 | 155.4 | 151.2 | False | None | None | False | None | False | 23496.48 | 0 |
| 2315841 | 68320 | None | 8.2.1 V-II | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.With all lead and lifts as per the direction of engineer incharge | Sqm | 309.75 | 309.75 | 99.18 | False | None | None | False | None | False | 30721.005 | 0 |
| 2315842 | 68320 | None | 8.3.1 V-II | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. With all lead and lifts as per the direction of engineer incharge | Sqm | 371.7 | 371.7 | 99.37 | False | None | None | False | None | False | 36935.829 | 0 |
| 2315843 | 68320 | None | 9.37 V-II | Providing and laying red oxide flooring 40 mm thick, with an under layer of 30mm thick M-15 cement concrete and top layer of 10mm thick plaster with 1:3 cement mortar mixed with red oxide finished with floating coat of neat cement mixed with red oxide ( mix of same proportion ) , including cost of materials, labour, curing, complete as per specifications.With all lead and lifts as per the direction of engineer incharge | Sqm | 825.3 | 825.3 | 45.26 | False | None | None | False | None | False | 37353.078 | 0 |
| 2315844 | 68320 | None | 8.84 V-II | Providing wall black boards in 12mm thick with CM 1:3 and applied with primer & two coats of acrylic emulsion black paint including finishing etc.,complete. With all lead and lifts as per the direction of engineer incharge | Sqm | 498.75 | 498.75 | 2.88 | False | None | None | False | None | False | 1436.4 | 0 |
| 2315845 | 68320 | None | 8.25 V-II | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. With all lead and lifts as per the direction of engineer incharge | Sqm | 143.85 | 143.85 | 94.68 | False | None | None | False | None | False | 13619.718 | 0 |
| 2315846 | 68320 | None | 8.32 V-II | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-chargeWith all lead and lifts as per the direction of engineer incharge | Sqm | 163.8 | 163.8 | 123.42 | False | None | None | False | None | False | 20216.196 | 0 |
| 2315847 | 68320 | None | 8.40 V-II | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.With all lead and lifts as per the direction of engineer incharge | Sqm | 120.75 | 120.75 | 17.82 | False | None | None | False | None | False | 2151.765 | 0 |
| 2315848 | 68320 | None | 13.47 V-II | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 75 mm diameter With all lead and lifts as per the direction of engineer incharge | Mtr | 206.85 | 206.85 | 8.0 | False | None | None | False | None | False | 1654.8 | 0 |
| 2315849 | 68320 | None | 1.3.1 PWD ELE V-VI | Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 19mm dia 2mm thick | Rmtr | 68.0 | 68.0 | 19.0 | False | None | None | False | None | False | 1292.0 | 0 |
| 2315850 | 68320 | None | 1.3.1 PWD ELE V-VI | Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 25mm dia 2mm thick | Rmtr | 79.0 | 79.0 | 24.0 | False | None | None | False | None | False | 1896.0 | 0 |
| 2315851 | 68320 | None | 1.7.1 PWD ELE V-VI | Groove cutting Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of conduit/GI pipe and plastering, finishing upto wall surface complete. upto 50 mm conduit in brick wall | Rmtr | 29.0 | 29.0 | 50.0 | False | None | None | False | None | False | 1450.0 | 0 |
| 2315852 | 68320 | None | 1.4 PWD ELE V-VI | Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc.135 x 75 x 65 mm | Each | 139.0 | 139.0 | 2.0 | False | None | None | False | None | False | 278.0 | 0 |
| 2315853 | 68320 | None | 1.4 PWD ELE V-VI | Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc. 200 x 200 x 65 mm | Each | 348.0 | 348.0 | 1.0 | False | None | None | False | None | False | 348.0 | 0 |
| 2315854 | 68320 | None | 1.5 PWD ELE V-VI | Supplying and fixing PVC/metal conduit Deep junction box 19/20 mm deep Junction box | Each | 49.0 | 49.0 | 4.0 | False | None | None | False | None | False | 196.0 | 0 |
| 2315855 | 68320 | None | 1.5 PWD ELE V-VI | Supplying and fixing PVC/metal conduit Deep junction box 25 mm deep Junction box | Each | 56.0 | 56.0 | 4.0 | False | None | None | False | None | False | 224.0 | 0 |
| 2315856 | 68320 | None | 1.11 PWD ELE V-VI | Supplying and Fixing 'S' Hook made out of 14mm dia M.S.Rod | Rmtr | 52.0 | 52.0 | 8.0 | False | None | None | False | None | False | 416.0 | 0 |
| 2315857 | 68320 | None | 2.1.1 PWD ELE V-VI | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm 2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3m from tapping point to out let via switch | Point | 285.0 | 285.0 | 2.0 | False | None | None | False | None | False | 570.0 | 0 |
| 2315858 | 68320 | None | 3.5.1 PWD ELE V-VI | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 1 to 3 Module | Each | 137.0 | 137.0 | 4.0 | False | None | None | False | None | False | 548.0 | 0 |
| 2315859 | 68320 | None | 3.5.1 PWD ELE V-VI | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 6 Module | Each | 234.0 | 234.0 | 2.0 | False | None | None | False | None | False | 468.0 | 0 |
| 2315860 | 68320 | None | 3.4 PWD ELE V-VI | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-3 Way | Each | 138.0 | 138.0 | 2.0 | False | None | None | False | None | False | 276.0 | 0 |
| 2315861 | 68320 | None | 3.4 PWD ELE V-VI | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6 Way | Each | 220.0 | 220.0 | 3.0 | False | None | None | False | None | False | 660.0 | 0 |
| 2315862 | 68320 | None | 3.6.1 PWD ELE V-VI | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6A One Way Switch | Each | 102.0 | 102.0 | 2.0 | False | None | None | False | None | False | 204.0 | 0 |
| 2315863 | 68320 | None | 3.6.1 PWD ELE V-VI | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6A Two Way Switch | Each | 166.0 | 166.0 | 2.0 | False | None | None | False | None | False | 332.0 | 0 |
| 2315864 | 68320 | None | 3.6.1 PWD ELE V-VI | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6A Stepped Fan Regulator Two Module | Each | 357.0 | 357.0 | 2.0 | False | None | None | False | None | False | 714.0 | 0 |
| 2315865 | 68320 | None | 3.6.1 PWD ELE V-VI | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6A TV/Telephone Socket | Each | 156.0 | 156.0 | 1.0 | False | None | None | False | None | False | 156.0 | 0 |
| 2315866 | 68320 | None | 3.7 PWD ELE V-VI | Supplying and fixing 32A security and energy saving DP switch with key tag suitable to operate on 230 V, 50Hz AC supply & completely wired on existing box. | Each | 646.0 | 646.0 | 1.0 | False | None | None | False | None | False | 646.0 | 0 |
| 2315867 | 68320 | None | 3.8 PWD ELE V-VI | Supplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc, and fixing on existing wooden or metal box using N.F. screws. | Each | 0.41 | 0.41 | 10.0 | False | None | None | False | None | False | 4.1 | 0 |
| 2315868 | 68320 | None | 3.1.2 PWD ELE V-VI | Supplying ......way plastic gang box and fixing using necessary wooden/ rawl/phill plugs and screws. 1 Way Gang Box | Each | 23.0 | 23.0 | 2.0 | False | None | None | False | None | False | 46.0 | 0 |
| 2315869 | 68320 | None | 3.1.2 PWD ELE V-VI | Supplying ......way plastic gang box and fixing using necessary wooden/ rawl/phill plugs and screws. 2 to 4 Way Gang Box | Each | 32.0 | 32.0 | 2.0 | False | None | None | False | None | False | 64.0 | 0 |
| 2315870 | 68320 | None | 3.1.4 PWD ELE V-VI | Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. | Each | 70.0 | 70.0 | 1.0 | False | None | None | False | None | False | 70.0 | 0 |
| 2315871 | 68320 | None | 5.4.1 PWD ELE V-VI | Fixing a shunt capacitor of ... kVAR capacity with necessary clA, bolts, and nuts on existing wooden or metal board including banking of more than one capacitor. | Each | 154.0 | 154.0 | 1.0 | False | None | None | False | None | False | 154.0 | 0 |
| 2315872 | 68320 | None | 2.3.1 PWD ELE V-VI | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.1 mm2 | Each | 19.0 | 19.0 | 23.0 | False | None | None | False | None | False | 437.0 | 0 |
| 2315873 | 68320 | None | 2.3.1 PWD ELE V-VI | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 mm2 | Each | 42.0 | 42.0 | 18.0 | False | None | None | False | None | False | 756.0 | 0 |
| 2315874 | 68320 | None | 5.6.6 PWD ELE V-VI | Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws 20" x 20" x 2.5" | Each | 326.13 | 326.13 | 1.0 | False | None | None | False | None | False | 326.13 | 0 |
| 2315875 | 68320 | None | 5.7.1 PWD ELE V-VI | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. 16 Amps | Each | 157.0 | 157.0 | 1.0 | False | None | None | False | None | False | 157.0 | 0 |
| 2315876 | 68320 | None | 5.19.1 PWD ELE V-VI | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. 4 Way SP & N | Each | 1241.0 | 1241.0 | 1.0 | False | None | None | False | None | False | 1241.0 | 0 |
| 2315877 | 68320 | None | 6.3.1 PWD ELE V-VI | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. 48" Sweep (1200 mm) Regular model | Each | 2984.0 | 2984.0 | 2.0 | False | None | None | False | None | False | 5968.0 | 0 |
| 2315878 | 68320 | None | 11.3.1 PWD ELE V-VI | Supplying of .....feet -PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 2' - 9/10 W | Each | 551.0 | 551.0 | 3.0 | False | None | None | False | None | False | 1653.0 | 0 |