tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1706177975000 | 1 | None | None | Buildings | Reconstruction of Public service building for widening of Yeyyadi Gundalike road of 32 Kadri North wad in MCC limits | 1494174.19 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2299922 | 67780 | None | code01 | Dismantling tiled roofing with battens, boarding etc. complete including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge (Page No. 166 Item No.19.30 Buildings SR 2021-22 VOLUME-2 ). | Sqm | 122.08 | 122.08 | 56.7 | False | None | None | False | None | False | 6921.936 | 0 | 2299923 | 67780 | None | code02 | Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead Rubble stone masonry in cement mortar. (Page No.8 Item No2.10 (iv) B road and Bridge works SR 2021-22 VOLUME-3 ). | Cum | 538.72 | 538.72 | 22.57 | False | None | None | False | None | False | 12158.9104 | 0 | 2299924 | 67780 | None | code03 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth(Page No. 8 Item No.1.15.1 COMMON SR 2021-22 VOLUME-1 ). | Cum | 304.64 | 304.64 | 47.15 | False | None | None | False | None | False | 14363.776 | 0 | 2299925 | 67780 | None | code04 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates (Page No. 15 Item No.-2.1.2 common SR 2021-22 VOLUME-1 ). | Cum | 5736.64 | 5736.64 | 8.78 | False | None | None | False | None | False | 50367.6992 | 0 | 2299926 | 67780 | None | code05 | Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc I.S 3620/1979 having compressive Strength not less then 3.5 N/mm2 for Saturated Dry Samples FOR FOUNDATION in c.m 1:6 (1st addenda For vol 1,2,&3 Shedule of RAte W.E.F 21-04-2022 ITEM NO-6.35) | Cum | 6265.28 | 6265.28 | 15.93 | False | None | None | False | None | False | 99805.9104 | 0 | 2299927 | 67780 | None | code06 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Page No. 15 Item No.-2.2.1.1 common SR 2021-22 VOLUME-1 ). | Cum | 6678.19 | 6678.19 | 9.88 | False | None | None | False | None | False | 65980.5172 | 0 | 2299928 | 67780 | None | code07 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Page No. 15 Item No.-2.3.2 common SR 2021-22 VOLUME-1 ). | Cum | 10049.76 | 10049.76 | 3.71 | False | None | None | False | None | False | 37284.6096 | 0 | 2299929 | 67780 | None | code08 | Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc I.S 3620/1979 having compressive Strength not less then 3.5 N/mm2 for Saturated Dry Samples FOR Super Structure in c.m 1:6 (1st addenda For vol 1,2,&3 Shedule of RAte W.E.F 21-04-2022 ITEM NO-6.35) | Cum | 6611.36 | 6611.36 | 16.45 | False | None | None | False | None | False | 108756.872 | 0 | 2299930 | 67780 | None | code09 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ( Page no 17, item no 6.34 ,Buildings SR 2021-22 Volume-2 ). | Sqm | 1059.52 | 1059.52 | 45.76 | False | None | None | False | None | False | 48483.6352 | 0 | 2299931 | 67780 | None | code10 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M30Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Page No. 17 Item No.-2.5.3common SR 2021-22 VOLUME-1 ). | Cum | 11384.9 | 11384.9 | 1.37 | False | None | None | False | None | False | 15597.313 | 0 | 2299932 | 67780 | None | code11 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Page No. 17 Item No.-2.5.1common SR 2021-22 VOLUME-1 ). | Cum | 9548.8 | 9548.8 | 4.3 | False | None | None | False | None | False | 41059.84 | 0 | 2299933 | 67780 | None | code12 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Page No. 17 Item No.-2.5.1common SR 2021-22 VOLUME-1 ). | Cum | 8952.0 | 8952.0 | 13.73 | False | None | None | False | None | False | 122910.96 | 0 | 2299934 | 67780 | None | code13 | Providing Thermo-Mechanically Treated bars of grade Fe-550D Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) (Page No.84 Item No.-11.32 Building SR 2021-22 VOLUME-2 ). | Kg | 100.8 | 100.8 | 2955.21 | False | None | None | False | None | False | 297885.168 | 0 | 2299935 | 67780 | None | code14 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (Page No. 7 Item No.-1.9 common SR 2021-22 VOLUME-1 ). | Cum | 228.48 | 228.48 | 91.61 | False | None | None | False | None | False | 20931.0528 | 0 | 2299936 | 67780 | None | code15 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Page no 41, item no 8.3.1,Buildings SR 2021-22 Volume-2 ). | Sqm | 334.88 | 334.88 | 330.19 | False | None | None | False | None | False | 110574.0272 | 0 | 2299937 | 67780 | None | code16 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding( Page no 85, item no 11.34A ,Building SR 2021-22 Volume-2 ). | Kg | 164.64 | 164.64 | 238.14 | False | None | None | False | None | False | 39207.3696 | 0 | 2299938 | 67780 | None | code17 | Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications. ( Page no 99, item no 12.12 ,Building SR 2021-22 Volume-2 ). | Cum | 84385.28 | 84385.28 | 0.2 | False | None | None | False | None | False | 16877.056 | 0 | 2299939 | 67780 | None | code18 | Providing and fixing in position fully panelled Matti/Nandi wood shutters for doors with , stiles and rails of 30mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures). ( Page no 101, item no 12.21 ,Building SR 2021-22 Volume-2 ). | Sqm | 4323.2 | 4323.2 | 3.78 | False | None | None | False | None | False | 16341.696 | 0 | 2299940 | 67780 | None | code19 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. ( Page no 107 , item no 12.60 ,Building SR 2021-22 Volume-2 ). | No | 931.84 | 931.84 | 2.0 | False | None | None | False | None | False | 1863.68 | 0 | 2299941 | 67780 | None | code20 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete( Page no 107 , item no 12.62 ,Building SR 2021-22 Volume-2 ). | No | 192.64 | 192.64 | 4.0 | False | None | None | False | None | False | 770.56 | 0 | 2299942 | 67780 | None | code21 | Providing and fixing IS : 12817 marked stainless steel butt hinges withstainless steel screws etc. complete :100x58x1.90mm( Page no 108 , item no 12.74.2 ,Building SR 2021-22 Volume-2 ). | No | 81.76 | 81.76 | 12.0 | False | None | None | False | None | False | 981.12 | 0 | 2299943 | 67780 | None | code22 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete 200x10mm ( Page no 109 , item no 12.76.2 ,Building SR 2021-22 Volume-2 ). | No | 305.76 | 305.76 | 4.0 | False | None | None | False | None | False | 1223.04 | 0 | 2299944 | 67780 | None | code23 | Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6 PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets -grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 44mm width x 40mmheight with reinforcement of 1mm thickness and Sash with overall size of 27mm X 53mm with UPVC honeycomb structure inside in lieu of GI reinforcement. Coextruded Glazing bead for fixing of glass shall be of size 9.5mm x 21.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with Crescent Locks. Wall thickness of frame & sash shall be of 2 mm.Maximum possible size 1219mm x 1219mm. (The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made)Page no 112, item no 12.90,Building SR 2021-22 Volume-2 ). | Kg | 4607.68 | 4607.68 | 13.5 | False | None | None | False | None | False | 62203.68 | 0 | 2299945 | 67780 | None | code24 | Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per direction of Engineer incharge.( Page no 59, item no 8.3.1,Buildings SR 2021-22 Volume-2 ). | Sqm | 810.88 | 810.88 | 39.44 | False | None | None | False | None | False | 31981.1072 | 0 | 2299946 | 67780 | None | code25 | Providing and laying vitrified floor tiles in 600x600mm sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete..( Page no 60, item no 9.12.2,Buildings SR 2021-22 Volume-2 ). | Sqm | 1229.76 | 1229.76 | 39.01 | False | None | None | False | None | False | 47972.9376 | 0 | 2299947 | 67780 | None | code26 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete ( Page no 60, item no 9.11,Buildings SR 2021-22 Volume-2 ). | Sqm | 853.44 | 853.44 | 2.63 | False | None | None | False | None | False | 2244.5472 | 0 | 2299948 | 67780 | None | code27 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. ( Page no 71, item no 10.14 ,Buildings SR 2021-22 Volume-2 ). | Sqm | 1090.88 | 1090.88 | 11.28 | False | None | None | False | None | False | 12305.1264 | 0 | 2299949 | 67780 | None | code28 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 110mm dia., 6 kg/sqcm & class 3 (P No. 134 Sl No. 1.7W.S and UGD WORKS S.R 2021-22 VOLUME -V). | Rmtr | 410.29 | 410.29 | 6.0 | False | None | None | False | None | False | 2461.74 | 0 | 2299950 | 67780 | None | code29 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 50mm dia., 6 kg/sqcm & class 3 (P No. 134 Sl No.1.3 W.S and UGD WORKS S.R 2021-22 VOLUME -V). | Rmtr | 99.99 | 99.99 | 18.0 | False | None | None | False | None | False | 1799.82 | 0 | 2299951 | 67780 | None | code30 | Providing and fixing white vitreous china wash basin including making all connections but including the cost of fittings :Flat back wash basin of size 550x400 mm ( Page no 127, item no 14.25 ,Buildings SR 2021-22 Volume-2 ). | No | 955.36 | 955.36 | 1.0 | False | None | None | False | None | False | 955.36 | 0 | 2299952 | 67780 | None | code31 | Providing and fixing white vitreous china water closet squatting pan(Indian type) :Orissa pattern W.C. pan of size 580x440 mm ( Page no 126, item no 14.13.2,Buildings SR 2021-22 Volume-2 ). | Each | 2418.08 | 2418.08 | 1.0 | False | None | None | False | None | False | 2418.08 | 0 | 2299953 | 67780 | None | code32 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required ( Page no 123, item no 14.2,Buildings SR 2021-22 Volume-2 ). | Each | 4509.12 | 4509.12 | 1.0 | False | None | None | False | None | False | 4509.12 | 0 | 2299954 | 67780 | None | code33 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931( Page no 117, item no13.12 ,Buildings SR 2021-22 Volume-2 ). | No | 483.84 | 483.84 | 4.0 | False | None | None | False | None | False | 1935.36 | 0 | 2299955 | 67780 | None | code34 | Providing and fixing Chorinated Poly Vinyl Chloride (CPVC) pipes 20mm dia having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete. (external work) (1st Addenda RAte. item no-13.33.2 Building S.R 2021-22 VOLUME -2) | Rmtr | 240.8 | 240.8 | 30.0 | False | None | None | False | None | False | 7224.0 | 0 | 2299956 | 67780 | None | code35 | Providing and fixing Chorinated Poly Vinyl Chloride (CPVC) pipes 25mm dia having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete. (external work) (1st Addenda RAte. item no-13.33.3 Building S.R 2021-22 VOLUME -2) | Rmtr | 334.88 | 334.88 | 30.0 | False | None | None | False | None | False | 10046.4 | 0 | 2299957 | 67780 | None | code36 | Providing and fixing Chorinated Poly Vinyl Chloride (CPVC) pipes 40mm dia having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete. (external work) (1st Addenda RAte. item no-13.33.5 Building S.R 2021-22 VOLUME -2) | Rmtr | 525.28 | 525.28 | 12.0 | False | None | None | False | None | False | 6303.36 | 0 | 2299958 | 67780 | None | code37 | Supplying 15mm C.P Brass TAp (sl.no 694 page no-A-33 Building S.R 2021-22 VOLUME -2) | No | 302.4 | 302.4 | 4.0 | False | None | None | False | None | False | 1209.6 | 0 | 2299959 | 67780 | None | code38 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 25mmNominal Bore ( Page no 115, item no 13.4.1 ,Building SR 2021-22 Volume-2 ). | No | 591.36 | 591.36 | 2.0 | False | None | None | False | None | False | 1182.72 | 0 | 2299960 | 67780 | None | code39 | Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover..( Page no 187, item no 10 ,W.S and UGD WORKS S.R 2021-22 VOLUME -V). | No | 4327.68 | 4327.68 | 1.0 | False | None | None | False | None | False | 4327.68 | 0 | 2299961 | 67780 | None | code40 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. ( Page no 105 , item no 12.54 ,Building SR 2021-22 Volume-2 ). | Sqm | 532.0 | 532.0 | 3.0 | False | None | None | False | None | False | 1596.0 | 0 | 2299962 | 67780 | None | code41 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.. ( Page no 105 , item no 12.54 ,Building SR 2021-22 Volume-2 ). | Sqm | 4259.36 | 4259.36 | 2.93 | False | None | None | False | None | False | 12479.9248 | 0 | 2299963 | 67780 | None | code42 | Providing and placing on Terrace ( at allLevels) Polyethylene water Storage Tank IS 12701 marked , with cover and Suitable locking arrangement and making nessary holea for inlet , outlet and Overflow Pipes but without Fittings and the base Support for Tank (1st addenda For vol 1,2,&3 Shedule of RAte W.E.F 21-04-2022 ITEM NO-13.34 volume-2 sr 2021-22 | Ltr | 8.96 | 8.96 | 1000.0 | False | None | None | False | None | False | 8960.0 | 0 | 2299964 | 67780 | None | code43 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. G.I. pipes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer in-Charge.( Page no82, item no 11.26.3,Building SR 2021-22 Volume-2 ). | Kg | 164.64 | 164.64 | 302.4 | False | None | None | False | None | False | 49787.136 | 0 | 2299965 | 67780 | None | code44 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge (Page no 45, item no 8.25,Buildings SR 2021-22 Volume-2 ). | Sqm | 117.6 | 117.6 | 189.49 | False | None | None | False | None | False | 22284.024 | 0 | 2299966 | 67780 | None | code45 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.( Page no 46, item no 8.31,Buildings SR 2021-22 Volume-2 ). | Sqm | 147.84 | 147.84 | 129.84 | False | None | None | False | None | False | 19195.5456 | 0 | 2299967 | 67780 | None | code46 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.( Page no 48, item no 8.40,Buildings SR 2021-22 Volume-2 ). | Sqm | 100.8 | 100.8 | 27.68 | False | None | None | False | None | False | 2790.144 | 0 | 2299968 | 67780 | None | code47 | Providing and laying heavy duty cobble stones 60mm thick interlock pavers, using cement and course sand for manufacture of blocks of approved size, shape and colour with a minimum compressive strength of 281 kg per m2 over 50mm thick sand bed ( average thickness ) and compacting with plate vibrator having 3 tons compaction force thereby forcing part of sand underneath to come up in between joints, final compaction of paver surface joints into its final level , including cost of materials, labour and Usage charges of machinery complete as per specifications. ( Page no 64, item no 9.31 ,Buildings SR 2021-22 Volume-2 ). | Sqm | 1217.44 | 1217.44 | 37.5 | False | None | None | False | None | False | 45654.0 | 0 |
| 1706177975000 | 1 | None | None | Buildings | Reconstruction of Public service building for widening of Yeyyadi Gundalike road of 32 Kadri North wad in MCC limits | 572780.38 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2299969 | 67781 | None | code01 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ( Page no 17, item no 6.34 ,Buildings SR 2021-22 Volume-2 ). | Sqm | 1070.12 | 1070.12 | 40.2 | False | None | None | False | None | False | 43018.824 | 0 | 2299970 | 67781 | None | code02 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Page no 41, item no 8.3.1,Buildings SR 2021-22 Volume-2 ). | Cum | 338.23 | 338.23 | 60.53 | False | None | None | False | None | False | 20473.0619 | 0 | 2299971 | 67781 | None | code03 | Providing and laying vitrified floor tiles in 600x600mm sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete..( Page no 60, item no 9.12.2,Buildings SR 2021-22 Volume-2 ). | Sqm | 1242.06 | 1242.06 | 68.68 | False | None | None | False | None | False | 85304.6808 | 0 | 2299972 | 67781 | None | code04 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.( Page no 46, item no 8.31,Buildings SR 2021-22 Volume-2 ). | Sqm | 149.32 | 149.32 | 71.66 | False | None | None | False | None | False | 10700.2712 | 0 | 2299973 | 67781 | None | code05 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.( Page no 81, item no 11.16.1,Buildings SR 2021-22 Volume-2 ). | Kg | 123.3 | 123.3 | 2238.98 | False | None | None | False | None | False | 276066.234 | 0 | 2299974 | 67781 | None | code06 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. ( Page no 26, item no 7.38 ,Buildings SR 2021-22 Volume-2 ). | Sqm | 628.95 | 628.95 | 130.0 | False | None | None | False | None | False | 81763.5 | 0 | 2299975 | 67781 | None | code07 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :Ridges Plain(500-600) ( Page no 27, item no 7.39.6 ,Buildings SR 2021-22 Volume-2 ). | Rmtr | 408.36 | 408.36 | 7.8 | False | None | None | False | None | False | 3185.208 | 0 | 2299976 | 67781 | None | code08 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :Gutter (600 mm over all girth) ( Page no 27, item no 7.39.6 ,Buildings SR 2021-22 Volume-2 ). | Rmtr | 967.18 | 967.18 | 22.0 | False | None | None | False | None | False | 21277.96 | 0 | 2299977 | 67781 | None | code09 | Providing and fixing on wall face unplasticised Rigid PVC Rain water pipes Conforming of IS13592 Type A inculding Jointing with seal ring Conforming of IS 5382 leaving 10mm gap for thermal Expension (I) single socketed Pipe 75mm diameter1st addenda For vol 1,2,&3 Shedule of RAte W.E.F 21-04-2022 ITEM NO-13.47 volume-2 sr 2021-22 | Rmtr | 200.22 | 200.22 | 24.0 | False | None | None | False | None | False | 4805.28 | 0 | 2299978 | 67781 | None | code10 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.( Page no 48, item no 8.40,Buildings SR 2021-22 Volume-2 ). | Sqm | 101.81 | 101.81 | 59.1 | False | None | None | False | None | False | 6016.971 | 0 | 2299979 | 67781 | None | code11 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. G.I PIPE including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineerin-Charge( Page no 82, item no 11.26.1 ,Building SR 2021-22 Volume-2 ). | Kg | 164.64 | 164.64 | 122.5 | False | None | None | False | None | False | 20168.4 | 0 |
| 1706178245000 | 1 | None | None | Buildings | Reconstruction of Public service building for widening of Yeyyadi Gundalike road of 32 Kadri North wad in MCC limits | 2066954.55 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2300740 | 67799 | None | code01 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ( Page no 17, item no 6.34 ,Buildings SR 2021-22 Volume-2 ). | Sqm | 1070.12 | 1070.12 | 40.2 | False | None | None | False | None | False | 43018.824 | 0 | 2300693 | 67799 | None | code01 | Dismantling tiled roofing with battens, boarding etc. complete including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge (Page No. 166 Item No.19.30 Buildings SR 2021-22 VOLUME-2 ). | Sqm | 122.08 | 122.08 | 56.7 | False | None | None | False | None | False | 6921.936 | 0 | 2300741 | 67799 | None | code02 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Page no 41, item no 8.3.1,Buildings SR 2021-22 Volume-2 ). | Cum | 338.23 | 338.23 | 60.53 | False | None | None | False | None | False | 20473.0619 | 0 | 2300694 | 67799 | None | code02 | Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead Rubble stone masonry in cement mortar. (Page No.8 Item No2.10 (iv) B road and Bridge works SR 2021-22 VOLUME-3 ). | Cum | 538.72 | 538.72 | 22.57 | False | None | None | False | None | False | 12158.9104 | 0 | 2300695 | 67799 | None | code03 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth(Page No. 8 Item No.1.15.1 COMMON SR 2021-22 VOLUME-1 ). | Cum | 304.64 | 304.64 | 47.15 | False | None | None | False | None | False | 14363.776 | 0 | 2300742 | 67799 | None | code03 | Providing and laying vitrified floor tiles in 600x600mm sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete..( Page no 60, item no 9.12.2,Buildings SR 2021-22 Volume-2 ). | Sqm | 1242.06 | 1242.06 | 68.68 | False | None | None | False | None | False | 85304.6808 | 0 | 2300696 | 67799 | None | code04 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates (Page No. 15 Item No.-2.1.2 common SR 2021-22 VOLUME-1 ). | Cum | 5736.64 | 5736.64 | 8.78 | False | None | None | False | None | False | 50367.6992 | 0 | 2300743 | 67799 | None | code04 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.( Page no 46, item no 8.31,Buildings SR 2021-22 Volume-2 ). | Sqm | 149.32 | 149.32 | 71.66 | False | None | None | False | None | False | 10700.2712 | 0 | 2300697 | 67799 | None | code05 | Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc I.S 3620/1979 having compressive Strength not less then 3.5 N/mm2 for Saturated Dry Samples FOR FOUNDATION in c.m 1:6 (1st addenda For vol 1,2,&3 Shedule of RAte W.E.F 21-04-2022 ITEM NO-6.35) | Cum | 6265.28 | 6265.28 | 15.93 | False | None | None | False | None | False | 99805.9104 | 0 | 2300744 | 67799 | None | code05 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.( Page no 81, item no 11.16.1,Buildings SR 2021-22 Volume-2 ). | Kg | 123.3 | 123.3 | 2238.98 | False | None | None | False | None | False | 276066.234 | 0 | 2300698 | 67799 | None | code06 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Page No. 15 Item No.-2.2.1.1 common SR 2021-22 VOLUME-1 ). | Cum | 6678.19 | 6678.19 | 9.88 | False | None | None | False | None | False | 65980.5172 | 0 | 2300745 | 67799 | None | code06 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. ( Page no 26, item no 7.38 ,Buildings SR 2021-22 Volume-2 ). | Sqm | 628.95 | 628.95 | 130.0 | False | None | None | False | None | False | 81763.5 | 0 | 2300699 | 67799 | None | code07 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Page No. 15 Item No.-2.3.2 common SR 2021-22 VOLUME-1 ). | Cum | 10049.76 | 10049.76 | 3.71 | False | None | None | False | None | False | 37284.6096 | 0 | 2300746 | 67799 | None | code07 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :Ridges Plain(500-600) ( Page no 27, item no 7.39.6 ,Buildings SR 2021-22 Volume-2 ). | Rmtr | 408.36 | 408.36 | 7.8 | False | None | None | False | None | False | 3185.208 | 0 | 2300700 | 67799 | None | code08 | Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc I.S 3620/1979 having compressive Strength not less then 3.5 N/mm2 for Saturated Dry Samples FOR Super Structure in c.m 1:6 (1st addenda For vol 1,2,&3 Shedule of RAte W.E.F 21-04-2022 ITEM NO-6.35) | Cum | 6611.36 | 6611.36 | 16.45 | False | None | None | False | None | False | 108756.872 | 0 | 2300747 | 67799 | None | code08 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :Gutter (600 mm over all girth) ( Page no 27, item no 7.39.6 ,Buildings SR 2021-22 Volume-2 ). | Rmtr | 967.18 | 967.18 | 22.0 | False | None | None | False | None | False | 21277.96 | 0 | 2300701 | 67799 | None | code09 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ( Page no 17, item no 6.34 ,Buildings SR 2021-22 Volume-2 ). | Sqm | 1059.52 | 1059.52 | 45.76 | False | None | None | False | None | False | 48483.6352 | 0 | 2300748 | 67799 | None | code09 | Providing and fixing on wall face unplasticised Rigid PVC Rain water pipes Conforming of IS13592 Type A inculding Jointing with seal ring Conforming of IS 5382 leaving 10mm gap for thermal Expension (I) single socketed Pipe 75mm diameter1st addenda For vol 1,2,&3 Shedule of RAte W.E.F 21-04-2022 ITEM NO-13.47 volume-2 sr 2021-22 | Rmtr | 200.22 | 200.22 | 24.0 | False | None | None | False | None | False | 4805.28 | 0 | 2300702 | 67799 | None | code10 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M30Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Page No. 17 Item No.-2.5.3common SR 2021-22 VOLUME-1 ). | Cum | 11384.9 | 11384.9 | 1.37 | False | None | None | False | None | False | 15597.313 | 0 | 2300749 | 67799 | None | code10 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.( Page no 48, item no 8.40,Buildings SR 2021-22 Volume-2 ). | Sqm | 101.81 | 101.81 | 59.1 | False | None | None | False | None | False | 6016.971 | 0 | 2300703 | 67799 | None | code11 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Page No. 17 Item No.-2.5.1common SR 2021-22 VOLUME-1 ). | Cum | 9548.8 | 9548.8 | 4.3 | False | None | None | False | None | False | 41059.84 | 0 | 2300750 | 67799 | None | code11 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. G.I PIPE including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineerin-Charge( Page no 82, item no 11.26.1 ,Building SR 2021-22 Volume-2 ). | Kg | 164.64 | 164.64 | 122.5 | False | None | None | False | None | False | 20168.4 | 0 | 2300704 | 67799 | None | code12 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Page No. 17 Item No.-2.5.1common SR 2021-22 VOLUME-1 ). | Cum | 8952.0 | 8952.0 | 13.73 | False | None | None | False | None | False | 122910.96 | 0 | 2300705 | 67799 | None | code13 | Providing Thermo-Mechanically Treated bars of grade Fe-550D Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) (Page No.84 Item No.-11.32 Building SR 2021-22 VOLUME-2 ). | Kg | 100.8 | 100.8 | 2955.21 | False | None | None | False | None | False | 297885.168 | 0 | 2300706 | 67799 | None | code14 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (Page No. 7 Item No.-1.9 common SR 2021-22 VOLUME-1 ). | Cum | 228.48 | 228.48 | 91.61 | False | None | None | False | None | False | 20931.0528 | 0 | 2300707 | 67799 | None | code15 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Page no 41, item no 8.3.1,Buildings SR 2021-22 Volume-2 ). | Sqm | 334.88 | 334.88 | 330.19 | False | None | None | False | None | False | 110574.0272 | 0 | 2300708 | 67799 | None | code16 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding( Page no 85, item no 11.34A ,Building SR 2021-22 Volume-2 ). | Kg | 164.64 | 164.64 | 238.14 | False | None | None | False | None | False | 39207.3696 | 0 | 2300709 | 67799 | None | code17 | Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications. ( Page no 99, item no 12.12 ,Building SR 2021-22 Volume-2 ). | Cum | 84385.28 | 84385.28 | 0.2 | False | None | None | False | None | False | 16877.056 | 0 | 2300710 | 67799 | None | code18 | Providing and fixing in position fully panelled Matti/Nandi wood shutters for doors with , stiles and rails of 30mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures). ( Page no 101, item no 12.21 ,Building SR 2021-22 Volume-2 ). | Sqm | 4323.2 | 4323.2 | 3.78 | False | None | None | False | None | False | 16341.696 | 0 | 2300711 | 67799 | None | code19 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. ( Page no 107 , item no 12.60 ,Building SR 2021-22 Volume-2 ). | No | 931.84 | 931.84 | 2.0 | False | None | None | False | None | False | 1863.68 | 0 | 2300712 | 67799 | None | code20 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete( Page no 107 , item no 12.62 ,Building SR 2021-22 Volume-2 ). | No | 192.64 | 192.64 | 4.0 | False | None | None | False | None | False | 770.56 | 0 | 2300713 | 67799 | None | code21 | Providing and fixing IS : 12817 marked stainless steel butt hinges withstainless steel screws etc. complete :100x58x1.90mm( Page no 108 , item no 12.74.2 ,Building SR 2021-22 Volume-2 ). | No | 81.76 | 81.76 | 12.0 | False | None | None | False | None | False | 981.12 | 0 | 2300714 | 67799 | None | code22 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete 200x10mm ( Page no 109 , item no 12.76.2 ,Building SR 2021-22 Volume-2 ). | No | 305.76 | 305.76 | 4.0 | False | None | None | False | None | False | 1223.04 | 0 | 2300715 | 67799 | None | code23 | Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6 PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets -grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 44mm width x 40mmheight with reinforcement of 1mm thickness and Sash with overall size of 27mm X 53mm with UPVC honeycomb structure inside in lieu of GI reinforcement. Coextruded Glazing bead for fixing of glass shall be of size 9.5mm x 21.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with Crescent Locks. Wall thickness of frame & sash shall be of 2 mm.Maximum possible size 1219mm x 1219mm. (The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made)Page no 112, item no 12.90,Building SR 2021-22 Volume-2 ). | Kg | 4607.68 | 4607.68 | 13.5 | False | None | None | False | None | False | 62203.68 | 0 | 2300716 | 67799 | None | code24 | Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per direction of Engineer incharge.( Page no 59, item no 8.3.1,Buildings SR 2021-22 Volume-2 ). | Sqm | 810.88 | 810.88 | 39.44 | False | None | None | False | None | False | 31981.1072 | 0 | 2300717 | 67799 | None | code25 | Providing and laying vitrified floor tiles in 600x600mm sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete..( Page no 60, item no 9.12.2,Buildings SR 2021-22 Volume-2 ). | Sqm | 1229.76 | 1229.76 | 39.01 | False | None | None | False | None | False | 47972.9376 | 0 | 2300718 | 67799 | None | code26 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete ( Page no 60, item no 9.11,Buildings SR 2021-22 Volume-2 ). | Sqm | 853.44 | 853.44 | 2.63 | False | None | None | False | None | False | 2244.5472 | 0 | 2300719 | 67799 | None | code27 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. ( Page no 71, item no 10.14 ,Buildings SR 2021-22 Volume-2 ). | Sqm | 1090.88 | 1090.88 | 11.28 | False | None | None | False | None | False | 12305.1264 | 0 | 2300720 | 67799 | None | code28 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 110mm dia., 6 kg/sqcm & class 3 (P No. 134 Sl No. 1.7W.S and UGD WORKS S.R 2021-22 VOLUME -V). | Rmtr | 410.29 | 410.29 | 6.0 | False | None | None | False | None | False | 2461.74 | 0 | 2300721 | 67799 | None | code29 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 50mm dia., 6 kg/sqcm & class 3 (P No. 134 Sl No.1.3 W.S and UGD WORKS S.R 2021-22 VOLUME -V). | Rmtr | 99.99 | 99.99 | 18.0 | False | None | None | False | None | False | 1799.82 | 0 | 2300722 | 67799 | None | code30 | Providing and fixing white vitreous china wash basin including making all connections but including the cost of fittings :Flat back wash basin of size 550x400 mm ( Page no 127, item no 14.25 ,Buildings SR 2021-22 Volume-2 ). | No | 955.36 | 955.36 | 1.0 | False | None | None | False | None | False | 955.36 | 0 | 2300723 | 67799 | None | code31 | Providing and fixing white vitreous china water closet squatting pan(Indian type) :Orissa pattern W.C. pan of size 580x440 mm ( Page no 126, item no 14.13.2,Buildings SR 2021-22 Volume-2 ). | Each | 2418.08 | 2418.08 | 1.0 | False | None | None | False | None | False | 2418.08 | 0 | 2300724 | 67799 | None | code32 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required ( Page no 123, item no 14.2,Buildings SR 2021-22 Volume-2 ). | Each | 4509.12 | 4509.12 | 1.0 | False | None | None | False | None | False | 4509.12 | 0 | 2300725 | 67799 | None | code33 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931( Page no 117, item no13.12 ,Buildings SR 2021-22 Volume-2 ). | No | 483.84 | 483.84 | 4.0 | False | None | None | False | None | False | 1935.36 | 0 | 2300726 | 67799 | None | code34 | Providing and fixing Chorinated Poly Vinyl Chloride (CPVC) pipes 20mm dia having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete. (external work) (1st Addenda RAte. item no-13.33.2 Building S.R 2021-22 VOLUME -2) | Rmtr | 240.8 | 240.8 | 30.0 | False | None | None | False | None | False | 7224.0 | 0 | 2300727 | 67799 | None | code35 | Providing and fixing Chorinated Poly Vinyl Chloride (CPVC) pipes 25mm dia having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete. (external work) (1st Addenda RAte. item no-13.33.3 Building S.R 2021-22 VOLUME -2) | Rmtr | 334.88 | 334.88 | 30.0 | False | None | None | False | None | False | 10046.4 | 0 | 2300728 | 67799 | None | code36 | Providing and fixing Chorinated Poly Vinyl Chloride (CPVC) pipes 40mm dia having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete. (external work) (1st Addenda RAte. item no-13.33.5 Building S.R 2021-22 VOLUME -2) | Rmtr | 525.28 | 525.28 | 12.0 | False | None | None | False | None | False | 6303.36 | 0 | 2300729 | 67799 | None | code37 | Supplying 15mm C.P Brass TAp (sl.no 694 page no-A-33 Building S.R 2021-22 VOLUME -2) | No | 302.4 | 302.4 | 4.0 | False | None | None | False | None | False | 1209.6 | 0 | 2300730 | 67799 | None | code38 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 25mmNominal Bore ( Page no 115, item no 13.4.1 ,Building SR 2021-22 Volume-2 ). | No | 591.36 | 591.36 | 2.0 | False | None | None | False | None | False | 1182.72 | 0 | 2300731 | 67799 | None | code39 | Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover..( Page no 187, item no 10 ,W.S and UGD WORKS S.R 2021-22 VOLUME -V). | No | 4327.68 | 4327.68 | 1.0 | False | None | None | False | None | False | 4327.68 | 0 | 2300732 | 67799 | None | code40 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. ( Page no 105 , item no 12.54 ,Building SR 2021-22 Volume-2 ). | Sqm | 532.0 | 532.0 | 3.0 | False | None | None | False | None | False | 1596.0 | 0 | 2300733 | 67799 | None | code41 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.. ( Page no 105 , item no 12.54 ,Building SR 2021-22 Volume-2 ). | Sqm | 4259.36 | 4259.36 | 2.93 | False | None | None | False | None | False | 12479.9248 | 0 | 2300734 | 67799 | None | code42 | Providing and placing on Terrace ( at allLevels) Polyethylene water Storage Tank IS 12701 marked , with cover and Suitable locking arrangement and making nessary holea for inlet , outlet and Overflow Pipes but without Fittings and the base Support for Tank (1st addenda For vol 1,2,&3 Shedule of RAte W.E.F 21-04-2022 ITEM NO-13.34 volume-2 sr 2021-22 | Ltr | 8.96 | 8.96 | 1000.0 | False | None | None | False | None | False | 8960.0 | 0 | 2300735 | 67799 | None | code43 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. G.I. pipes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer in-Charge.( Page no82, item no 11.26.3,Building SR 2021-22 Volume-2 ). | Kg | 164.64 | 164.64 | 302.4 | False | None | None | False | None | False | 49787.136 | 0 | 2300736 | 67799 | None | code44 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge (Page no 45, item no 8.25,Buildings SR 2021-22 Volume-2 ). | Sqm | 117.6 | 117.6 | 189.49 | False | None | None | False | None | False | 22284.024 | 0 | 2300737 | 67799 | None | code45 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.( Page no 46, item no 8.31,Buildings SR 2021-22 Volume-2 ). | Sqm | 147.84 | 147.84 | 129.84 | False | None | None | False | None | False | 19195.5456 | 0 | 2300738 | 67799 | None | code46 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.( Page no 48, item no 8.40,Buildings SR 2021-22 Volume-2 ). | Sqm | 100.8 | 100.8 | 27.68 | False | None | None | False | None | False | 2790.144 | 0 | 2300739 | 67799 | None | code47 | Providing and laying heavy duty cobble stones 60mm thick interlock pavers, using cement and course sand for manufacture of blocks of approved size, shape and colour with a minimum compressive strength of 281 kg per m2 over 50mm thick sand bed ( average thickness ) and compacting with plate vibrator having 3 tons compaction force thereby forcing part of sand underneath to come up in between joints, final compaction of paver surface joints into its final level , including cost of materials, labour and Usage charges of machinery complete as per specifications. ( Page no 64, item no 9.31 ,Buildings SR 2021-22 Volume-2 ). | Sqm | 1217.44 | 1217.44 | 37.5 | False | None | None | False | None | False | 45654.0 | 0 |
|
|
---|