| 1706344043000 | 0 | None | None | Buildings | Construction of Classroom at GHPS Ramathirtha in Harihara taluk | 841067.72 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 2316150 | 68332 | None | 1.13 | Earth work in surface excavation by mechanical means for lowering & leveling
the ground without blasting for all works other than foundation in Ordinary/
Soft rock & depth not exceeding 300mm as per drawing and technical
specifications, including setting out, shoring, strutting, barricading, caution
lights, removal of stumps and other deleterious matter including dressing of
excavated surfaces, disposing off or levelling the excavated earth or sorting
& stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5
m including cost of labour, tools, usage of machinery & other appurtenances
required to complete the work In Ordinary/Soft rock upto 300 mm depth | Cum | 380.1 | 380.1 | 5.85 | False | None | None | False | None | False | 2223.585 | 0 | | 2316151 | 68332 | None | 1.14.1 | Earth work excavation for Foundation by mechanical means for all works &
depth upto 3 m, as per drawing and technical specifications, including setting
out, shoring, strutting, barricading, caution lights, including dressing of
excavated surfaces, disposing off or levelling the excavated earth or sorting
& stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5
m including cost of labour, tools, usage of machinery & other appurtenaces
required to complete the work | Cum | 107.1 | 107.1 | 40.05 | False | None | None | False | None | False | 4289.355 | 0 | | 2316152 | 68332 | None | 2.1.3 | Providing and laying in position Cement Concrete for levelling course for
all works in foundation. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in
layers not exceeding 150 mm thickness, well compacted using plate vibrators,
including all lead & lifts, cost of all materials of quality, labour, Usage charges of
machinery, curing, and all the other appurtenances required to complete the
work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6288.45 | 6288.45 | 7.17 | False | None | None | False | None | False | 45088.1865 | 0 | | 2316153 | 68332 | None | 5.2 | Providing Coursed rubble masonry (first sort) with hard stone in foundation
and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6948.9 | 6948.9 | 10.66 | False | None | None | False | None | False | 74075.274 | 0 | | 2316154 | 68332 | None | 5.4 | Providing Size Stone masonry with hard stone in foundation & plinth with
Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6708.45 | 6708.45 | 6.9 | False | None | None | False | None | False | 46288.305 | 0 | | 2316155 | 68332 | None | 1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of
foundations and other similar works etc. in layers not exceeding 20cm in depth,
consolidating each deposited layer by ramming and watering, lead up to 50 m
and lift upto 1.5 m. | Cum | 279.3 | 279.3 | 16.92 | False | None | None | False | None | False | 4725.756 | 0 | | 2316156 | 68332 | None | 1.8 | Construction of Embankment by excavating the
available approved Gravel/Murrum deposited at a
place or borrow pits during or prior excavation with
all lifts and lead, transportation to site, spreading,
grading to required slope and compacting to meet the
requirement complete as per specifications, including
cost of labour,rolling,water,all materials,usage & all
other appurtenaces required to complete the work. | Cum | 497.7 | 497.7 | 11.7 | False | None | None | False | None | False | 5823.09 | 0 | | 2316157 | 68332 | None | 2.1.4 | Providing and laying in position Cement Concrete for levelling course for
all works in foundation. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in
layers not exceeding 150 mm thickness, well compacted using plate vibrators,
including all lead & lifts, cost of all materials of quality, labour, Usage charges of
machinery, curing, and all the other appurtenances required to complete the
work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6527.85 | 6527.85 | 1.31 | False | None | None | False | None | False | 8551.4835 | 0 | | 2316158 | 68332 | None | 2.2.1 | Providing and laying in position Cement Concrete for all Foundation works.
The granite/trap/basalt crushed graded coarse aggregates and fine aggregates
as per relevant IS Codes machine mixed with super plasticizers laid in finished
layers, well compacted using needle vibrators, including all lead & lifts, cost
of all materials, quality confirming to the requirements of relevant IS codes,
labour, Usage charges of machinery, curing and all the other appurtenances
required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6799.39 | 6799.39 | 4.56 | False | None | None | False | None | False | 31005.2184 | 0 | | 2316159 | 68332 | None | 2.2.1 | Providing and laying in position Cement Concrete for all Foundation works.
The granite/trap/basalt crushed graded coarse aggregates and fine aggregates
as per relevant IS Codes machine mixed with super plasticizers laid in finished
layers, well compacted using needle vibrators, including all lead & lifts, cost
of all materials, quality confirming to the requirements of relevant IS codes,
labour, Usage charges of machinery, curing and all the other appurtenances
required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11222.3 | 11222.3 | 1.06 | False | None | None | False | None | False | 11895.638 | 0 | | 2316160 | 68332 | None | 2.3.1 | Providing and laying in Cement Concrete for all Basement & surface level
works, return walls, retaining walls, sunken floors etc. The granite/trap/
basalt crushed graded coarse aggregates and fine aggregates as per relevant
IS Codes machine mixed with super plasticisers, laid in layers, well compacted
using needle vibrators, providing weep holes wherever necessary, including all
lead & lifts, cost of all materials of quality, labour, Usage charges of machinery,
curing and all other appurtenances required to complete the work as per
technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 9958.73 | 9958.73 | 2.47 | False | None | None | False | None | False | 24598.0631 | 0 | | 2316161 | 68332 | None | 2.5.1 | Providing and laying in position Cement Concrete for all Super structures of
building , Road works, Water works, Irrigation works & super structure works
of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed with
super plasticisers laid in layers, well compacted using needle vibrators. The
cost includes all lead & lifts, cost of all materials, quality confirming to the
requirements of relevant IS codes , labour, Usage charges of machinery, curing
and all other appurtenances required to complete the work as per technical
specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11834.55 | 11834.55 | 2.05 | False | None | None | False | None | False | 24260.8275 | 0 | | 2316162 | 68332 | None | 2.5.1 | Providing and laying in position Cement Concrete for all Super structures of
building , Road works, Water works, Irrigation works & super structure works
of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed with
super plasticisers laid in layers, well compacted using needle vibrators. The
cost includes all lead & lifts, cost of all materials, quality confirming to the
requirements of relevant IS codes , labour, Usage charges of machinery, curing
and all other appurtenances required to complete the work as per technical
specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11138.4 | 11138.4 | 0.66 | False | None | None | False | None | False | 7351.344 | 0 | | 2316163 | 68332 | None | 2.5.1 | Providing and laying in position Cement Concrete for all Super structures of
building , Road works, Water works, Irrigation works & super structure works
of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed with
super plasticisers laid in layers, well compacted using needle vibrators. The
cost includes all lead & lifts, cost of all materials, quality confirming to the
requirements of relevant IS codes , labour, Usage charges of machinery, curing
and all other appurtenances required to complete the work as per technical
specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 10094.18 | 10094.18 | 0.14 | False | None | None | False | None | False | 1413.1852 | 0 | | 2316164 | 68332 | None | 2.5.1 | Providing and laying in position Cement Concrete for all Super structures of
building , Road works, Water works, Irrigation works & super structure works
of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed with
super plasticisers laid in layers, well compacted using needle vibrators. The
cost includes all lead & lifts, cost of all materials, quality confirming to the
requirements of relevant IS codes , labour, Usage charges of machinery, curing
and all other appurtenances required to complete the work as per technical
specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11138.4 | 11138.4 | 2.14 | False | None | None | False | None | False | 23836.176 | 0 | | 2316165 | 68332 | None | 2.5.1 | Providing and laying in position Cement Concrete for all Super structures of
building , Road works, Water works, Irrigation works & super structure works
of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed with
super plasticisers laid in layers, well compacted using needle vibrators. The
cost includes all lead & lifts, cost of all materials, quality confirming to the
requirements of relevant IS codes , labour, Usage charges of machinery, curing
and all other appurtenances required to complete the work as per technical
specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 10442.25 | 10442.25 | 4.82 | False | None | None | False | None | False | 50331.645 | 0 | | 2316166 | 68332 | None | 2.11A | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement
including cost of all materials, machinery, labour, cleaning, straightening,
cutting, bending, hooking, laping/welding joints, tying with binding wire / soft
annealed steel wire and other ancilary operations complete as per drawing and
technical specification | Tonne | 93929.85 | 93929.85 | 1.484 | False | None | None | False | None | False | 139391.8974 | 0 | | 2316167 | 68332 | None | 6.8 | Providing Brick work with common burnt clay Non Modular bricks of
class designation 3.5 in superstructure above plinth level in all shapes and
sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of
all materials, labour, scaffolding and usage charges of machinery & other
incidental charges complete as per the direction of engineer incharge of
work. | Cum | 8367.45 | 8367.45 | 13.77 | False | None | None | False | None | False | 115219.7865 | 0 | | 2316168 | 68332 | None | 8.8 | Providing 18 mm cement plaster in two coats under layer 12 mm thick
cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished
with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1
cement : 6 fine sand) to brick masonry including rounding off corners
wherever required smooth rendering, providing and removing scaffolding,
including cost of materials, labour, curing complete as per specifications
and as per directions of Engineer-in-charge. | Sqm | 389.55 | 389.55 | 80.64 | False | None | None | False | None | False | 31413.312 | 0 | | 2316169 | 68332 | None | 8.4.2 | Providing 12 mm cement plaster finished with a floating coat of neat
cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including
rounding off corners wherever required smooth rendering, providing and
removing scaffolding, including cost of materials, labour, curing complete
as per specifications and as per directions of Engineer-in-charge. | Sqm | 327.6 | 327.6 | 76.28 | False | None | None | False | None | False | 24989.328 | 0 | | 2316170 | 68332 | None | 8.19.1 | Providing Flush/ Ruled pointing: Pointing on stone work with cement
mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining,
including cost of materials, labour, curing as per specifications and as
per directions of Engineer-in-charge | Sqm | 267.75 | 267.75 | 12.09 | False | None | None | False | None | False | 3237.0975 | 0 | | 2316171 | 68332 | None | 11.5.1 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6
mm angle iron and 3 mm M.S. gusset plates at the junctions and
corners, all necessary fittings complete, including applying a priming
coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal
braces including cost of materials, labour, usage charges of machinery
complete as per specifications and as per directions of the Engineer-in-
Charge. | Sqm | 4701.9 | 4701.9 | 4.2 | False | None | None | False | None | False | 19747.98 | 0 | | 2316172 | 68332 | None | 11.11.1 | Providing and fixing factory made ISI marked steel glazed doors, windows
and ventilators, side /top /centre hung, with beading and all members
such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel
sections, joints mitred and flash butt welded and sash bars tenoned
and riveted, including providing and fixing of hinges, pivots, including
priming coat of approved steel primer, but excluding the cost of other
fittings, complete all as per approved design, (sectional weight of only
steel members shall be measured for payment).
Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete
block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone
aggregate 20 mm nominal size) including cost of materials, labour, usage
charges of machinery complete as per specifications and as per directions
of the Engineer-in-Charge. | Sqm | 155.4 | 155.4 | 97.2 | False | None | None | False | None | False | 15104.88 | 0 | | 2316173 | 68332 | None | 8.25 | Distempering with oil bound washable distemper of approved brand
and manufacture to give an even shade :New work (two coats) over and including
water thinnable priming coat with cement primer after thoroughly
brooming the surface to remove all dirt, dust, mortar drops and foreign
matter including preparing the surface even and sand paper smooth, cost
of materials, labour complete as per specifications and as per directions
of Engineer-in-charge. | Sqm | 143.85 | 143.85 | 99.42 | False | None | None | False | None | False | 14301.567 | 0 | | 2316174 | 68332 | None | 8.33.1 | Finishing with Deluxe Multi surface paint system for interiors and exteriors
using Primer as per manufacturers specifications: Two coats applied on
walls @ 1.25 L/10 m² over and including one coat of Special primer applied
@ 0.75 L/10 m² with paint of approved quality to give an even shade, after
thoroughly brooming the surface to remove all dirt, dust, mortar drops
and foreign matter including preparing the surface even and sand paper
smooth, cost of materials, labour complete as per specifications and as per
directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree
angle with 10 years life) | Sqm | 165.9 | 165.9 | 108.44 | False | None | None | False | None | False | 17990.196 | 0 | | 2316175 | 68332 | None | 8.33.3 | Painting Steel work with Deluxe Multi Surface Paint to give an even
shade. Two coat applied @ 0.90L/10 m² over an under coat of primer
applied @ 0.80 L/10 m² of approved brand and manufacture including
preparing the surface after thorougly cleaning oil, grease, dirt and foreign
matter, cost of materials, labour complete as per specifications and as per
directions of Engineer-in-charge. | Sqm | 145.95 | 145.95 | 16.74 | False | None | None | False | None | False | 2443.203 | 0 | | 2316176 | 68332 | None | 9.22.2 | Providing and laying Polished Glazed Vitrified tiles with thickness 10
mm in floor with different sizes with water absorption less than 0.08%
and conforming to IS:15622, of approved brand & manufacturer, in all
colours and shade, laid with cement based high polymer modified quick
set tile adhesive (water based) conforming to IS : 15477, in average 6 mm
thickness, including grouting of joints (Payment for grouting of joints to
be made separately). Size of Tile 600x600 mm | Mtr | 1392.3 | 1392.3 | 30.34 | False | None | None | False | None | False | 42242.382 | 0 | | 2316177 | 68332 | None | 003 | Supplying and fixing Raindown water PVC Pipe 110mm outer dia at 2kg per cm2. | Mtr | 152.0 | 152.0 | 6.0 | False | None | None | False | None | False | 912.0 | 0 | | 2316178 | 68332 | None | 11.28 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow
tubes, channels, plates etc., including welding, grinding, buffing, polishing
and making curvature (wherever required) and fitting the same with
necessary stainless steel nuts and bolts complete, i/c fixing the railing
with necessary accessories & stainless steel dash fasteners, stainless
steel bolts etc., of required size, on the top of the floor or the side of waist
slab with suitable arrangement as per approval of Engineer-in- charge,
(for payment purpose only weight of stainless steel members shall be
considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
including cost of materials, labour, usage charges of machinery complete
as per specifications and as per directions of the Engineer-in-Charge. | Kg | 593.25 | 593.25 | 21.0 | False | None | None | False | None | False | 12458.25 | 0 | | 2316179 | 68332 | None | 1.7.1 | Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete. upto 50 mm conduit in brick wall | Mtr | 29.0 | 29.0 | 42.0 | False | None | None | False | None | False | 1218.0 | 0 | | 2316180 | 68332 | None | 1.1.2 | Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 25 mm dia 2 mm thick | Mtr | 81.0 | 81.0 | 54.0 | False | None | None | False | None | False | 4374.0 | 0 | | 2316181 | 68332 | None | 2.1.1 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch | Point | 285.0 | 285.0 | 5.0 | False | None | None | False | None | False | 1425.0 | 0 | | 2316182 | 68332 | None | 2.1.2 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 6m upto 6m from tapping point to out let via switch | Point | 394.0 | 394.0 | 5.0 | False | None | None | False | None | False | 1970.0 | 0 | | 2316183 | 68332 | None | 3.1.1 | Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 6A 2 Way | Each | 128.0 | 128.0 | 8.0 | False | None | None | False | None | False | 1024.0 | 0 | | 2316184 | 68332 | None | 2.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 mm2 | Mtr | 63.0 | 63.0 | 165.0 | False | None | None | False | None | False | 10395.0 | 0 | | 2316185 | 68332 | None | 3.6.3 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A Three Way socket | Each | 171.0 | 171.0 | 6.0 | False | None | None | False | None | False | 1026.0 | 0 | | 2316186 | 68332 | None | 5.18.4 | Supplying&fixingminiaturecircuitbreakersonexistingMCBdistributionboardsusingnecessaryfixingmaterialsand'C'Typecurve,indicatorON/OFF,energycross-3withShortcircuitbreakingcapacityof10KandcompletewiringasrequiredconfirmingtoIEC60898. | Each | 739.0 | 739.0 | 1.0 | False | None | None | False | None | False | 739.0 | 0 | | 2316187 | 68332 | None | 6.3.1 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. 48" Sweep (1200 mm) Regular model | Each | 2984.0 | 2984.0 | 2.0 | False | None | None | False | None | False | 5968.0 | 0 | | 2316188 | 68332 | None | 11.11.5 | Supplying & fixing of retrofit type - LED bulb ...... W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per W, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 12W, 6500K | Each | 269.0 | 269.0 | 5.0 | False | None | None | False | None | False | 1345.0 | 0 | | 2316189 | 68332 | None | 6.4.6 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 | Mtr | 225.0 | 225.0 | 15.0 | False | None | None | False | None | False | 3375.0 | 0 | | 2316190 | 68332 | None | 6.1 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit … The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per ISI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia | No | 2999.7 | 2999.7 | 1.0 | False | None | None | False | None | False | 2999.7 | 0 |
|