2322315 | 68617 | None | Item 01 | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer.A In area of light jungle A.In area of light jungle ---- etc., complete with all lead | Sqm | 463.74 | 463.74 | 18.1078 | False | None | None | False | None | False | 8397.311172 | 0 |
2322316 | 68617 | None | Item 02 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.In all kinds of soil upto 300 mm depth ---- etc., complete with all lead | Cum | 112.1 | 112.1 | 635.7794 | False | None | None | False | None | False | 71270.87074 | 0 |
2322317 | 68617 | None | Item 03 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work, In all types of soil upto 3.00 m depth ---- etc., complete with all lead | Cum | 120.36 | 120.36 | 1383.1552 | False | None | None | False | None | False | 166476.559872 | 0 |
2322318 | 68617 | None | Item 04 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work, In ordinary/soft rock without blasting upto 1.5 m depth ---- etc., complete with all lead | Cum | 428.34 | 428.34 | 140.4657 | False | None | None | False | None | False | 60167.077938 | 0 |
2322319 | 68617 | None | Item 05 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates ---- etc., complete with all lead | Cum | 7067.02 | 7067.02 | 512.6354 | False | None | None | False | None | False | 3622804.624508 | 0 |
2322320 | 68617 | None | Item 06 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. ---- etc., complete with all lead | Sqm | 139.24 | 139.24 | 573.6467 | False | None | None | False | None | False | 79874.566508 | 0 |
2322321 | 68617 | None | Item 07 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Footing ---- etc., complete with all lead | Cum | 8074.6 | 8074.6 | 115.803 | False | None | None | False | None | False | 935062.9038 | 0 |
2322322 | 68617 | None | Item 08 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Column Pedestal and RCC Wall ---- etc., complete with all lead | Cum | 8224.13 | 8224.13 | 40.0095 | False | None | None | False | None | False | 329043.329235 | 0 |
2322323 | 68617 | None | Item 09 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Columns ---- etc., complete with all lead | Cum | 13727.06 | 13727.06 | 40.5979 | False | None | None | False | None | False | 557289.809174 | 0 |
2322324 | 68617 | None | Item 10 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Plinth Beam, Roof Slab and Stair case ---- etc., complete with all lead | Cum | 12112.11 | 12112.11 | 148.6694 | False | None | None | False | None | False | 1800700.126434 | 0 |
2322325 | 68617 | None | Item 11 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Lintel, Roof Beam ---- etc., complete with all lead | Cum | 12919.58 | 12919.58 | 47.7679 | False | None | None | False | None | False | 617141.205482 | 0 |
2322326 | 68617 | None | Item 12 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete with all lead | Cum | 313.88 | 313.88 | 785.922 | False | None | None | False | None | False | 246685.19736 | 0 |
2322327 | 68617 | None | Item 13 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. ---- etc., complete with all lead | Cum | 559.32 | 559.32 | 578.4 | False | None | None | False | None | False | 323510.688 | 0 |
2322328 | 68617 | None | Item 14 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification ---- etc., complete with all lead | Tonne | 105559.26 | 105559.26 | 56.6134 | False | None | None | False | None | False | 5976068.610084 | 0 |
2322329 | 68617 | None | Item 15 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all lead | Cum | 10637.29 | 10637.29 | 53.9802 | False | None | None | False | None | False | 574203.041658 | 0 |
2322330 | 68617 | None | Item 16 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete with all lead | Sqm | 1545.8 | 1545.8 | 1463.1498 | False | None | None | False | None | False | 2261736.96084 | 0 |
2322331 | 68617 | None | Item 17 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete with all lead | Sqm | 1302.72 | 1302.72 | 300.1425 | False | None | None | False | None | False | 391001.6376 | 0 |
2322332 | 68617 | None | Item 18 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- etc., complete with all lead | Sqm | 116601.7 | 116601.7 | 3.1444 | False | None | None | False | None | False | 366642.38548 | 0 |
2322333 | 68617 | None | Item 19 | Providing and fixing factory made single extruded WPC (Wood Polymer
Composite) solid door/window/Clerestory windows & other Frames/
Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension
Grade), calcium carbonate and natural fibres (wood powder/rice husk/
wheat husk) and non toxic additives (maximum toxicity index of 12 for
100 g) fabricated with miter joints after applying PVC solvent cement and
screwed with full body threaded star headed SS screws having minimum
frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) &
1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of
elasticity 900 N/mm2 and resistance to spread of flame of Class A category
with property of being termite/borer proof, water/moisture proof and fire
retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners
of required dia and length complete as per direction of Engineer-InCharge.
(Fixtures shall be paid for separately) Size 62 x 100mm ---- etc., complete with all lead | m | 828.36 | 828.36 | 69.55 | False | None | None | False | None | False | 57612.438 | 0 |
2322334 | 68617 | None | Item 20 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- etc., complete with all lead | Nos | 1198.88 | 1198.88 | 43.0 | False | None | None | False | None | False | 51551.84 | 0 |
2322335 | 68617 | None | Item 21 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- etc., complete with all lead | Kg | 198.24 | 198.24 | 2961.0 | False | None | None | False | None | False | 586988.64 | 0 |
2322336 | 68617 | None | Item 22 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete with all lead | Sqm | 5284.04 | 5284.04 | 17.7 | False | None | None | False | None | False | 93527.508 | 0 |
2322337 | 68617 | None | Item 23 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. ---- etc., complete with all lead | Nos | 4551.26 | 4551.26 | 86.13 | False | None | None | False | None | False | 392000.0238 | 0 |
2322338 | 68617 | None | Item 24 | Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer ofK value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) 30 mm thickness ---- etc., complete with all lead | Nos | 4112.3 | 4112.3 | 20.475 | False | None | None | False | None | False | 84199.3425 | 0 |
2322339 | 68617 | None | Item 25 | Providing and fixing IS : 12817 marked stainless steel butt hinges withstainless steel screws etc. complete :125x64x1.90mm ---- etc., complete with all lead | Nos | 120.36 | 120.36 | 164.0 | False | None | None | False | None | False | 19739.04 | 0 |
2322340 | 68617 | None | Item 26 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :200x10mm ---- etc., complete with all lead | Nos | 413.0 | 413.0 | 164.0 | False | None | None | False | None | False | 67732.0 | 0 |
2322341 | 68617 | None | Item 27 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete ---- etc., complete with all lead | Nos | 279.66 | 279.66 | 102.0 | False | None | None | False | None | False | 28525.32 | 0 |
2322342 | 68617 | None | Item 28 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. ---- etc., complete with all lead | Nos | 141.6 | 141.6 | 82.0 | False | None | None | False | None | False | 11611.2 | 0 |
2322343 | 68617 | None | Item 29 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all lead | Sqm | 7946.12 | 7946.12 | 123.72 | False | None | None | False | None | False | 983093.9664 | 0 |
2322344 | 68617 | None | Item 30 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size - 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all lead | Sqm | 6748.42 | 6748.42 | 11.88 | False | None | None | False | None | False | 80171.2296 | 0 |
2322345 | 68617 | None | Item 31 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding,
including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead | Sqm | 248.98 | 248.98 | 655.0116 | False | None | None | False | None | False | 163084.788168 | 0 |
2322346 | 68617 | None | Item 32 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge... ( Inside) ---- etc., complete with all lead | Sqm | 368.16 | 368.16 | 1589.1761 | False | None | None | False | None | False | 585071.072976 | 0 |
2322347 | 68617 | None | Item 33 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead | Sqm | 346.92 | 346.92 | 515.4096 | False | None | None | False | None | False | 178805.898432 | 0 |
2322348 | 68617 | None | Item 34 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete with all lead | Sqm | 118.0 | 118.0 | 2661.7336 | False | None | None | False | None | False | 314084.5648 | 0 |
2322349 | 68617 | None | Item 35 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Outside) ---- etc., complete with all lead | Sqm | 346.92 | 346.92 | 964.5631 | False | None | None | False | None | False | 334626.230652 | 0 |
2322350 | 68617 | None | Item 36 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. ---- etc., complete with all lead | m | 61.36 | 61.36 | 722.1 | False | None | None | False | None | False | 44308.056 | 0 |
2322351 | 68617 | None | Item 37 | Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm ---- etc., complete with all lead | Sqm | 1386.5 | 1386.5 | 575.5623 | False | None | None | False | None | False | 798017.12895 | 0 |
2322352 | 68617 | None | Item 38 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. ---- etc., complete with all lead | Sqm | 1049.02 | 1049.02 | 53.5316 | False | None | None | False | None | False | 56155.719032 | 0 |
2322353 | 68617 | None | Item 39 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 600x600 mm ---- etc., complete with all lead | Sqm | 246.62 | 246.62 | 388.8 | False | None | None | False | None | False | 95885.856 | 0 |
2322354 | 68617 | None | Item 40 | Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per direction of Engineer incharge. ---- etc., complete with all lead | Sqm | 944.0 | 944.0 | 108.0 | False | None | None | False | None | False | 101952.0 | 0 |
2322355 | 68617 | None | Item 41 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead | Sqm | 149.86 | 149.86 | 2226.1877 | False | None | None | False | None | False | 333616.488722 | 0 |
2322356 | 68617 | None | Item 42 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead | Sqm | 184.08 | 184.08 | 1724.2931 | False | None | None | False | None | False | 317407.873848 | 0 |
2322357 | 68617 | None | Item 43 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead | Sqm | 59.0 | 59.0 | 271.28 | False | None | None | False | None | False | 16005.52 | 0 |
2322358 | 68617 | None | Item 44 | Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade :Two coats on new work including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead | Sqm | 110.92 | 110.92 | 113.2 | False | None | None | False | None | False | 12556.144 | 0 |
2322359 | 68617 | None | Item 45 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead | Sqm | 62.54 | 62.54 | 67.446 | False | None | None | False | None | False | 4218.07284 | 0 |
2322360 | 68617 | None | Item 46 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead | Sqm | 135.7 | 135.7 | 199.21 | False | None | None | False | None | False | 27032.797 | 0 |
2322361 | 68617 | None | Item 47 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete with all lead | Kg | 666.7 | 666.7 | 220.943 | False | None | None | False | None | False | 147302.6981 | 0 |
2322362 | 68617 | None | Item 48 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : ** Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. ---- etc., complete with all lead | Sqm | 2909.88 | 2909.88 | 266.6047 | False | None | None | False | None | False | 775787.684436 | 0 |
2322363 | 68617 | None | Item 49 | Providing and Applying PU based Elastomeric Liquid Applied PU Waterproofing Membrane single component, cold applied, water based acrylic PU dispersion with highly elastic and UV resistant water proofing treatment to the Existing Roof surface/Chajjas/Sunken portion of WC:Bathroom applied @ 1.2L/per m2,having tensile strength greater than 1.5N/mm2, elongation greater than 300% with solid content not less than 60% in 2 coats including surface preparation, priming the surface with water based acrylic primer @0.1 L/m2, and spreading 60 gsm geotextile between two top coats completely as per specification. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. Polyurethane based Single Component for New Surface ---- etc., complete with all lead | Sqm | 964.06 | 964.06 | 621.126 | False | None | None | False | None | False | 598802.73156 | 0 |
2322364 | 68617 | None | Item 50 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete with all lead | Sqm | 1709.82 | 1709.82 | 562.3226 | False | None | None | False | None | False | 961470.427932 | 0 |
2322365 | 68617 | None | Item 51 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Columns ---- etc., complete with all lead | Cum | 13807.81 | 13807.81 | 1.64 | False | None | None | False | None | False | 22644.8084 | 0 |
2322366 | 68617 | None | Item 52 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Lintel Beam and Roof Beam ---- etc., complete with all lead | Cum | 11752.16 | 11752.16 | 3.95 | False | None | None | False | None | False | 46421.032 | 0 |
2322367 | 68617 | None | Item 53 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Chajja ---- etc., complete with all lead | Cum | 10657.24 | 10657.24 | 0.12 | False | None | None | False | None | False | 1278.8688 | 0 |
2322368 | 68617 | None | Item 54 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification ---- etc., complete with all lead | Tonne | 106614.85 | 106614.85 | 1.6252 | False | None | None | False | None | False | 173270.45422 | 0 |
2322369 | 68617 | None | Item 55 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete with all lead | Sqm | 1561.26 | 1561.26 | 123.968 | False | None | None | False | None | False | 193546.27968 | 0 |
2322370 | 68617 | None | Item 56 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3
fine sand) on concrete surface / ceilings including rounding off corners
wherever required smooth rendering, providing and removing scaffolding,
including cost of materials, labour, curing complete as per specifications
and as per directions of Engineer-in-charge. ---- etc., complete with all lead | Sqm | 251.47 | 251.47 | 17.29 | False | None | None | False | None | False | 4347.9163 | 0 |
2322371 | 68617 | None | Item 57 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge... ( Inside) ---- etc., complete with all lead | Sqm | 371.84 | 371.84 | 100.66 | False | None | None | False | None | False | 37429.4144 | 0 |
2322372 | 68617 | None | Item 58 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete with all lead | Sqm | 119.18 | 119.18 | 137.9686 | False | None | None | False | None | False | 16443.097748 | 0 |
2322373 | 68617 | None | Item 59 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. ( Outside) ---- etc., complete with all lead | Sqm | 350.39 | 350.39 | 80.2 | False | None | None | False | None | False | 28101.278 | 0 |
2322374 | 68617 | None | Item 60 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. ---- etc., complete with all lead | m | 61.97 | 61.97 | 30.45 | False | None | None | False | None | False | 1886.9865 | 0 |
2322375 | 68617 | None | Item 61 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead | Sqm | 151.36 | 151.36 | 137.9686 | False | None | None | False | None | False | 20882.927296 | 0 |
2322376 | 68617 | None | Item 62 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead | Sqm | 185.92 | 185.92 | 939.161 | False | None | None | False | None | False | 174608.81312 | 0 |
2322377 | 68617 | None | Item 63 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead | Sqm | 63.17 | 63.17 | 1.89 | False | None | None | False | None | False | 119.3913 | 0 |
2322378 | 68617 | None | Item 64 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead | Sqm | 137.06 | 137.06 | 5.79 | False | None | None | False | None | False | 793.5774 | 0 |
2322379 | 68617 | None | Item 65 | Providing and Applying PU based Elastomeric Liquid Applied PU Waterproofing Membrane single component, cold applied, water based acrylic PU dispersion with highly elastic and UV resistant water proofing treatment to the Existing Roof surface/Chajjas/Sunken portion of WC:Bathroom applied @ 1.2L/per m2,having tensile strength greater than 1.5N/mm2, elongation greater than 300% with solid content not less than 60% in 2 coats including surface preparation, priming the surface with water based acrylic primer @0.1 L/m2, and spreading 60 gsm geotextile between two top coats completely as per specification. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. ---- etc., complete with all lead | Sqm | 973.7 | 973.7 | 274.21 | False | None | None | False | None | False | 266998.277 | 0 |
2322380 | 68617 | None | Item 66 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40mm dia pipes, From wash basin waste lines 40mm dia pipes ---- etc., complete with all lead | m | 108.56 | 108.56 | 20.0 | False | None | None | False | None | False | 2171.2 | 0 |
2322381 | 68617 | None | Item 67 | Providing and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make including trench excavation and refilling etc. for EXTERNAL WORKS with: 50mm nominal bore pipes ---- etc., complete with all lead | m | 164.02 | 164.02 | 58.0 | False | None | None | False | None | False | 9513.16 | 0 |
2322382 | 68617 | None | Item 68 | PVC pipe - OD 75mm and 6 Kg/sqcm, waste lines and (Shaft Drainage) ---- etc., complete with all lead | m | 145.14 | 145.14 | 220.0 | False | None | None | False | None | False | 31930.8 | 0 |
2322383 | 68617 | None | Item 69 | PVC pipe - OD 110mm and 6 Kg/sqcm, sanitary lines and (Shaft Drainage) ---- etc., complete with all lead | m | 300.9 | 300.9 | 350.0 | False | None | None | False | None | False | 105315.0 | 0 |
2322384 | 68617 | None | Item 70 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 75mm diameter ---- etc., complete with all lead | m | 232.46 | 232.46 | 150.0 | False | None | None | False | None | False | 34869.0 | 0 |
2322385 | 68617 | None | Item 71 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter ---- etc., complete with all lead | m | 343.38 | 343.38 | 110.0 | False | None | None | False | None | False | 37771.8 | 0 |
2322386 | 68617 | None | Item 72 | Providing, fixing, testing and commissioning of deep seal PVC multi inlet floor trap of self cleansing design moulded or fabricated with CP grating, rubber ring / solvent cement followed by application of leak proof adhesive like FRP paste including making good the floors etc., complete as directed by the Engineer in charge & approved quality confirming to ISI or BIS Standards (Market Rate) ---- etc., complete with all lead | Nos | 371.7 | 371.7 | 20.0 | False | None | None | False | None | False | 7434.0 | 0 |
2322387 | 68617 | None | Item 73 | Drilling holes of 2.50 cms dia (roof/chajja/stone). in slabs upto 7.50 cms thick ---- etc., complete with all lead | Nos | 154.58 | 154.58 | 55.0 | False | None | None | False | None | False | 8501.9 | 0 |
2322388 | 68617 | None | Item 74 | Drilling holes of 2.50 cms dia (roof/chajja/stone). in slabs upto 10 cms thick ---- etc., complete with all lead | Nos | 185.26 | 185.26 | 55.0 | False | None | None | False | None | False | 10189.3 | 0 |
2322389 | 68617 | None | Item 75 | Supplying, fixing, testing and commissioning of Counter basin consisting of size: 420 x 590 x 195, Shape: oval of ISI or BIS Standards.complete as directed by the Engineer in charge. CNS-WHT-705, make Jaguar/hindware/Cera ---- etc., complete with all lead | Nos | 5664.0 | 5664.0 | 4.0 | False | None | None | False | None | False | 22656.0 | 0 |
2322390 | 68617 | None | Item 76 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. ---- etc., complete with all lead | Nos | 1145.78 | 1145.78 | 4.0 | False | None | None | False | None | False | 4583.12 | 0 |
2322391 | 68617 | None | Item 77 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm ---- etc., complete with all lead | Each | 1201.24 | 1201.24 | 5.0 | False | None | None | False | None | False | 6006.2 | 0 |
2322392 | 68617 | None | Item 78 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter ---- etc., complete with all lead | Nos | 329.22 | 329.22 | 9.0 | False | None | None | False | None | False | 2962.98 | 0 |
2322393 | 68617 | None | Item 79 | Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. ---- etc., complete with all lead | Nos | 6563.16 | 6563.16 | 8.0 | False | None | None | False | None | False | 52505.28 | 0 |
2322394 | 68617 | None | Item 80 | Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. ---- etc., complete with all lead | Nos | 13244.32 | 13244.32 | 6.0 | False | None | None | False | None | False | 79465.92 | 0 |
2322395 | 68617 | None | Item 81 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. ---- etc., complete with all lead | Nos | 585.28 | 585.28 | 10.0 | False | None | None | False | None | False | 5852.8 | 0 |
2322396 | 68617 | None | Item 82 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous chinaflushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mmflush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete,including painting of fittings and brackets, cutting and making goodthe walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid ---- etc., complete with all lead | Nos | 7052.86 | 7052.86 | 3.0 | False | None | None | False | None | False | 21158.58 | 0 |
2322397 | 68617 | None | Item 83 | Providing and fixing water closet squatting pan (Indian type W.C. pan )
with 100 mm sand cast Iron P or S trap, 10 litre low level white
P.V.C. flushing cistern, including flush pipe, with manually controlled
device (handle lever) conforming to IS : 7231, with all fittings and fixtures
complete, including cutting and making good the walls and floors wherever
required: ---- etc., complete with all lead | Nos | 5763.12 | 5763.12 | 3.0 | False | None | None | False | None | False | 17289.36 | 0 |
2322398 | 68617 | None | Item 84 | Supplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ). (Market Rate) ---- etc., complete with all lead | Nos | 2183.0 | 2183.0 | 3.0 | False | None | None | False | None | False | 6549.0 | 0 |
2322399 | 68617 | None | Item 85 | Providing & fixing White vitreous china water closet squatting pan (Indian type) along with "S" or "P" trap including dismantling of old WC seat and "S" or "P" trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge. Orissa pattern W.C Pan of size 580x440 mm ---- etc., complete with all lead | Each | 5763.12 | 5763.12 | 3.0 | False | None | None | False | None | False | 17289.36 | 0 |
2322400 | 68617 | None | Item 86 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : Range of three urinal basins with 10litre white P.V.C. automatic flushing
cistern ---- etc., complete with all lead | Nos | 11156.9 | 11156.9 | 4.0 | False | None | None | False | None | False | 44627.6 | 0 |
2322401 | 68617 | None | Item 87 | Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm ---- etc., complete with all lead | Nos | 5996.76 | 5996.76 | 4.0 | False | None | None | False | None | False | 23987.04 | 0 |
2322402 | 68617 | None | Item 88 | Supplying, fixing, testing and commissioning of Sink Cock with Swinging Casted Spout (Wall Mounted Model): CON-CHR-347KN for pantry sink with CP wall flange etc. Standard make confirming to ISI standards,Model as per attached photo catalogue and as per instruction of engineer incharge. ( Jaguar make or Equalent ) (Market Place) ---- etc., complete with all lead | Nos | 1146.96 | 1146.96 | 1.0 | False | None | None | False | None | False | 1146.96 | 0 |
2322403 | 68617 | None | Item 89 | Providing and fixing in position Exposed Part Kit of Concealed Stop Cock with Fitting Sleeve, Operating Lever & Adjustable Wall Flange (Compatible with ALD-087FT) ( Jaguar make or Equalent ) including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. (Market Place) ---- etc., complete with all lead | Nos | 1024.91 | 1024.91 | 2.0 | False | None | None | False | None | False | 2049.82 | 0 |
2322404 | 68617 | None | Item 90 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps ---- etc., complete with all lead | Nos | 3636.76 | 3636.76 | 8.0 | False | None | None | False | None | False | 29094.08 | 0 |
2322405 | 68617 | None | Item 91 | Supplying and fixing PCC Pedestal 450 x 250 x 200mm with MS sloted angle iron brackets, supports with necessary drilling holes to suit the insertion of pipe clamps deburning etc., as per detailed drawing for supporting water supply pipes with suitable MS clamps, bolts, anchor bolts, nuts and washers fixed on shaft walls / outer walls etc. The quoted rate shall include with the cost of brackets galvanizing with zinc alloy of 0.08mm thick conformed to IS 1239 etc., complete as directed by the employer. (Market Rate) ---- etc., complete with all lead | Nos | 767.0 | 767.0 | 30.0 | False | None | None | False | None | False | 23010.0 | 0 |
2322406 | 68617 | None | Item 92 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal dia Pipes ---- etc., complete with all lead | m | 195.88 | 195.88 | 200.0 | False | None | None | False | None | False | 39176.0 | 0 |
2322407 | 68617 | None | Item 93 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 20 mm nominal dia Pipes ---- etc., complete with all lead | m | 256.06 | 256.06 | 200.0 | False | None | None | False | None | False | 51212.0 | 0 |
2322408 | 68617 | None | Item 94 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 40 mm nominal dia Pipes ---- etc., complete with all lead | m | 562.86 | 562.86 | 200.0 | False | None | None | False | None | False | 112572.0 | 0 |
2322409 | 68617 | None | Item 95 | Supplying, installing, testing and commissioning of approved make full way lever operated forged brass ball valve of brass body with forged brass hard chromeplated steel ball tested to a pressure not less than 20 Kg / sqcm with threaded joints complete. a) 20mm dia (Market Rate) ---- etc., complete with all lead | Nos | 649.0 | 649.0 | 4.0 | False | None | None | False | None | False | 2596.0 | 0 |
2322410 | 68617 | None | Item 96 | Supplying, installing, testing and commissioning of approved make full way lever operated forged brass ball valve of brass body with forged brass hard chromeplated steel ball tested to a pressure not less than 20 Kg / sqcm with threaded joints complete.b) 25mm dia (Market Rate) ---- etc., complete with all lead | Nos | 944.0 | 944.0 | 2.0 | False | None | None | False | None | False | 1888.0 | 0 |
2322411 | 68617 | None | Item 97 | Providing and fixing Bib cock with wall flange made of Stainless steel with
all concealed fitting arrangements & all necessary accesories complete
- Class economy ---- etc., complete with all lead | Each | 1318.06 | 1318.06 | 2.0 | False | None | None | False | None | False | 2636.12 | 0 |
2322412 | 68617 | None | Item 98 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank. ---- etc., complete with all lead | Ltr | 10.62 | 10.62 | 7000.0 | False | None | None | False | None | False | 74340.0 | 0 |
2322413 | 68617 | None | Item 99 | O.T. S.S. Surgical Scrub Station - 2 Bay ; Floor mounted Size:- 2100 x 600 x 1000 + 300 mm LxWxH + Flashback Technical Specifications S.S. 304 Grade ; 16 SWG Floor mounted with slopy radius chamber 2 Electric ON- OFF Foot operated Switches for washing 1 manual Foot operated Valve connected to one Switch 2 manual wire rod Holders for liquid detergent container Flashback at 300 mm Height Nylon adjustable levelling bullets for legs Note: Plumbing and other accessories not in our scope ---- etc., complete with all lead | Ltr | 206500.0 | 206500.0 | 1.0 | False | None | None | False | None | False | 206500.0 | 0 |
2322414 | 68617 | None | Item 100 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board-510x1040 mm bowl depth 178 mm ---- etc., complete with all lead | Nos | 5701.76 | 5701.76 | 4.0 | False | None | None | False | None | False | 22807.04 | 0 |
2322415 | 68617 | None | Item 101 | C.P. Brass stop cock (concealed) 15 mm Sl.no.- 166 Page No A-16 ---- etc., complete with all lead | Nos | 619.5 | 619.5 | 12.0 | False | None | None | False | None | False | 7434.0 | 0 |
2322416 | 68617 | None | Item 102 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps ---- etc., complete with all lead | Nos | 4151.24 | 4151.24 | 6.0 | False | None | None | False | None | False | 24907.44 | 0 |
2322417 | 68617 | None | Item 103 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal dia Pipes ---- etc., complete with all lead | m | 364.62 | 364.62 | 150.0 | False | None | None | False | None | False | 54693.0 | 0 |
2322418 | 68617 | None | Item 104 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal dia Pipes ---- etc., complete with all lead | m | 562.86 | 562.86 | 60.0 | False | None | None | False | None | False | 33771.6 | 0 |
2322419 | 68617 | None | Item 105 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32 mm nominal dia Pipes ---- etc., complete with all lead | m | 657.26 | 657.26 | 60.0 | False | None | None | False | None | False | 39435.6 | 0 |
2322420 | 68617 | None | Item 106 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.internal work - exposed on wall 40 mm nominal dia Pipes ---- etc., complete with all lead | m | 632.48 | 632.48 | 25.0 | False | None | None | False | None | False | 15812.0 | 0 |
2322421 | 68617 | None | Item 107 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 25 mm nominal dia Pipes ---- etc., complete with all lead | m | 349.28 | 349.28 | 225.0 | False | None | None | False | None | False | 78588.0 | 0 |
2322422 | 68617 | None | Item 108 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 50 mm nominal dia Pipes ---- etc., complete with all lead | m | 850.78 | 850.78 | 350.0 | False | None | None | False | None | False | 297773.0 | 0 |
2322423 | 68617 | None | Item 109 | Brass full way valve with C.I. wheel (screwed end) 25 mm dia. (Sl No 109 Page No .A-15) ---- etc., complete with all lead | Nos | 442.5 | 442.5 | 20.0 | False | None | None | False | None | False | 8850.0 | 0 |
2322424 | 68617 | None | Item 110 | Brass full way valve with C.I. wheel (screwed end) 32 mm dia. (Sl No 109 Page No .A-15) ---- etc., complete with all lead | Nos | 489.7 | 489.7 | 20.0 | False | None | None | False | None | False | 9794.0 | 0 |
2322425 | 68617 | None | Item 111 | Brass bib-cock 15 mm dia ---- etc., complete with all lead | Nos | 188.8 | 188.8 | 6.0 | False | None | None | False | None | False | 1132.8 | 0 |
2322426 | 68617 | None | Item 112 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix 1:3 (1 cement: 3 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead | Sqm | 431.88 | 431.88 | 3.9 | False | None | None | False | None | False | 1684.332 | 0 |
2322427 | 68617 | None | Item 113 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m ---- etc., complete with all lead | Cum | 120.36 | 120.36 | 400.0 | False | None | None | False | None | False | 48144.0 | 0 |
2322428 | 68617 | None | Item 114 | Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:( For external Sanitary Work ). Pipes of SN4, 160mm dia. ---- etc., complete with all lead | m | 679.68 | 679.68 | 550.0 | False | None | None | False | None | False | 373824.0 | 0 |
2322429 | 68617 | None | Item 115 | Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:( For external Sanitary Work ). Pipes of SN4, 200mm dia. ---- etc., complete with all lead | m | 980.58 | 980.58 | 100.0 | False | None | None | False | None | False | 98058.0 | 0 |
2322430 | 68617 | None | Item 116 | Providing stoneware gully trap of approved quality and make fixing in M-15 and plastering with CM 1:3 wherever necessary.( Rate includes cost of all materials, fixtures and lead).15cms x 10cms. (SR. 2018-19) ---- etc., complete with all lead | Nos | 330.4 | 330.4 | 35.0 | False | None | None | False | None | False | 11564.0 | 0 |
2322431 | 68617 | None | Item 117 | Providing and fixing 150mm dia. Cast Iron pipe for ventilatiing shaft 5 M high with specials and cowl and with suitable grips in CC 1:2:4 pillar using 10mm to 20mm graded hard granite, with 15 cms. thick cement concrete 1:2:4 around upto 1.22 M above the GLR and with a foundation base of 90 x 90 x 90 cms. plastered with 12mm thick CM 1:3 to all exposed faces and linking the shaft to the manholes by means of 150mm dia. GSW pipes and specials, jointing with tar dipped hemp 1:1.5 CM caulking, curing. The cost include all lead and lifts for all materials, earth work excavations and refilling in all strata, disposal of surplus earth etc. complete ---- etc., complete with all lead | Nos | 24882.66 | 24882.66 | 5.0 | False | None | None | False | None | False | 124413.3 | 0 |
2322432 | 68617 | None | Item 118 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 65 mm nominal dia Pipes ---- etc., complete with all lead | m | 1652.0 | 1652.0 | 100.0 | False | None | None | False | None | False | 165200.0 | 0 |
2322433 | 68617 | None | Item 119 | Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. 50 mm nominal bore, 242mm long, weighing not less than 1240 g ---- etc., complete with all lead | Nos | 1585.92 | 1585.92 | 4.0 | False | None | None | False | None | False | 6343.68 | 0 |
2322434 | 68617 | None | Item 120 | Supplying heavy gauge PVC Conduit pipe…dia.. Mm thick confirming to IS 2509 with suitable size bends, metal/pvc junction boxes,adesive paste etc.., and running before concreting the slab .the conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using pvc end enclosures, run with 185WG GI fish wire wherever necessary. (P.No. 1/.I.No.1.2)PWD Electrical SR 22-23 19/20 mm dia 2mm thick ---- etc., complete with all lead | m | 77.88 | 77.88 | 630.0 | False | None | None | False | None | False | 49064.4 | 0 |
2322435 | 68617 | None | Item 121 | Supplying heavy gauge PVC Conduit pipe…dia.. Mm thick confirming to IS 2509 with suitable size bends, metal/pvc junction boxes,adesive paste etc.., and running before concreting the slab .the conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using pvc end enclosures, run with 185WG GI fish wire wherever necessary. (P.No. 1/.I.No.1.2)PWD Electrical SR 22-23 25mm dia 2mm thick ---- etc., complete with all lead | m | 92.04 | 92.04 | 1350.0 | False | None | None | False | None | False | 124254.0 | 0 |
2322436 | 68617 | None | Item 122 | Supplying heavy gauge pvc conduit pipe…dia.. Mm thick confirming to IS 2509 with suitable size bends ,metal junction boxes, adhesive paste etc by groove cutting in the wall and fixing by bracing Uor Jhooks and cement plastering upto the wall surface and run with 18SWG GI fish wire run thoughout the conduit wherever neccessary (P.No. 1/.I.No.1.3)PWD Electrical SR 22-23 19/20 mm dia 2mm thick ---- etc., complete with all lead | m | 80.24 | 80.24 | 200.0 | False | None | None | False | None | False | 16048.0 | 0 |
2322437 | 68617 | None | Item 123 | Supplying heavy gauge pvc conduit pipe…dia.. Mm thick confirming to IS 2509 with suitable size bends ,metal junction boxes, adhesive paste etc by groove cutting in the wall and fixing by bracing Uor Jhooks and cement plastering upto the wall surface and run with 18SWG GI fish wire run thoughout the conduit wherever neccessary (P.No. 1/.I.No.1.3)PWD Electrical SR 22-23 25mm dia 2mm thick ---- etc., complete with all lead | m | 93.22 | 93.22 | 575.0 | False | None | None | False | None | False | 53601.5 | 0 |
2322438 | 68617 | None | Item 124 | Supplying and fixing PVC/metal conduit Deep junction box (P.No. 1/.I.No.1.5)PWD Electrical SR 22-23 19/20 mm deep junction box ---- etc., complete with all lead | Each | 57.82 | 57.82 | 8.0 | False | None | None | False | None | False | 462.56 | 0 |
2322439 | 68617 | None | Item 125 | Supplying and fixing PVC/metal conduit Deep junction box (P.No. 1/.I.No.1.5)PWD Electrical SR 22-23 25 mm deep junction box ---- etc., complete with all lead | Each | 66.08 | 66.08 | 25.0 | False | None | None | False | None | False | 1652.0 | 0 |
2322440 | 68617 | None | Item 126 | Supplying And Fixing Metal Fan Box with Round Hook. (P.No.2/.I.No.1.11) PWD Electrical SR 22-23 ---- etc., complete with all lead | Nos | 142.2 | 142.2 | 25.0 | False | None | None | False | None | False | 3555.0 | 0 |
2322441 | 68617 | None | Item 127 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.(P.No.3/.I.No.2.2) PWD Electrical SR 22-23 short point upto 3mtr from tapping point to out let via switch box ---- etc., complete with all lead | Point | 317.42 | 317.42 | 52.0 | False | None | None | False | None | False | 16505.84 | 0 |
2322442 | 68617 | None | Item 128 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.(P.No.3/.I.No.2.2) PWD Electrical SR 22-23 Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch box ---- etc., complete with all lead | Point | 447.22 | 447.22 | 69.0 | False | None | None | False | None | False | 30858.18 | 0 |
2322443 | 68617 | None | Item 129 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.(P.No.3/.I.No.2.2) PWD Electrical SR 22-23 Long point above 6Mtr upto 10Mtr from tapping point to out let via switch box ---- etc., complete with all lead | Point | 654.9 | 654.9 | 108.0 | False | None | None | False | None | False | 70729.2 | 0 |
2322444 | 68617 | None | Item 130 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.(P.No.3/.I.No.2.2) PWD Electrical SR 22-23 Two outlet in a row, above 3Mtr upto 6Mtr from tapping point to out let via switches. ---- etc., complete with all lead | Point | 798.86 | 798.86 | 5.0 | False | None | None | False | None | False | 3994.3 | 0 |
2322445 | 68617 | None | Item 131 | Wiring for lighting / power circuit using one of FRLS PVC insulated1100V grade multi strand copper with low conductor resistance single core wire in open or consealed system of wiring.as per IS-694:1990 & confirming to latest amendments (P. No.3/ I.No.2.3) PWD Electrical SR 22-23 1.5 sqmrn ---- etc., complete with all lead | Mtr | 30.68 | 30.68 | 1000.0 | False | None | None | False | None | False | 30680.0 | 0 |
2322446 | 68617 | None | Item 132 | Wiring for lighting / power circuit using one of FRLS PVC insulated1100V grade multi strand copper with low conductor resistance single core wire in open or consealed system of wiring.as per IS-694:1990 & confirming to latest amendments (P. No.3/ I.No.2.3) PWD Electrical SR 22-23 2.5 sqmrn ---- etc., complete with all lead | Mtr | 49.56 | 49.56 | 2200.0 | False | None | None | False | None | False | 109032.0 | 0 |
2322447 | 68617 | None | Item 133 | Wiring for lighting / power circuit using one of FRLS PVC insulated1100V grade multi strand copper with low conductor resistance single core wire in open or consealed system of wiring.as per IS-694:1990 & confirming to latest amendments (P. No.3/ I.No.2.3) PWD Electrical SR 22-23 4.0 sqmrn ---- etc., complete with all lead | Mtr | 74.34 | 74.34 | 1150.0 | False | None | None | False | None | False | 85491.0 | 0 |
2322448 | 68617 | None | Item 134 | Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirmining to table 3 class 5 of IS:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100Volts as per IS:694-1990 (P.No.4/.I.No.2.6) PWD Electrical SR 22-23 3C X 4.0Sq.mm ---- etc., complete with all lead | Mtr | 198.24 | 198.24 | 100.0 | False | None | None | False | None | False | 19824.0 | 0 |
2322449 | 68617 | None | Item 135 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall (P. No.5/ I.No.3.4)PWD Electrical SR 22-23 1-2Way ---- etc., complete with all lead | Each | 162.84 | 162.84 | 40.0 | False | None | None | False | None | False | 6513.6 | 0 |
2322450 | 68617 | None | Item 136 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall (P. No.5/ I.No.3.4)PWD Electrical SR 22-23 3 Way ---- etc., complete with all lead | Each | 187.62 | 187.62 | 18.0 | False | None | None | False | None | False | 3377.16 | 0 |
2322451 | 68617 | None | Item 137 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall (P. No.5/ I.No.3.4)PWD Electrical SR 22-23 4-5Way ---- etc., complete with all lead | Each | 208.86 | 208.86 | 21.0 | False | None | None | False | None | False | 4386.06 | 0 |
2322452 | 68617 | None | Item 138 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall (P. No.5/ I.No.3.4)PWD Electrical SR 22-23 6Way ---- etc., complete with all lead | Each | 259.6 | 259.6 | 16.0 | False | None | None | False | None | False | 4153.6 | 0 |
2322453 | 68617 | None | Item 139 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall (P. No.5/ I.No.3.4)PWD Electrical SR 22-23 8 Way ---- etc., complete with all lead | Each | 307.98 | 307.98 | 28.0 | False | None | None | False | None | False | 8623.44 | 0 |
2322454 | 68617 | None | Item 140 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall (P. No.5/ I.No.3.4)PWD Electrical SR 22-23 10-12Way ---- etc., complete with all lead | Each | 376.42 | 376.42 | 12.0 | False | None | None | False | None | False | 4517.04 | 0 |
2322455 | 68617 | None | Item 141 | Supplying and fixing superior quality modular switch mounting polycorbonate plate with neceaary supporting back plate with rquired nos. of machine screwes, bolts nuts etc., complete on the existing metal/PVC box. (P. No.5/ I.No.3.5)PWD Electrical SR 22-23 1 to 2 Module ---- etc., complete with all lead | Each | 161.66 | 161.66 | 40.0 | False | None | None | False | None | False | 6466.4 | 0 |
2322456 | 68617 | None | Item 142 | Supplying and fixing superior quality modular switch mounting polycorbonate plate with neceaary supporting back plate with rquired nos. of machine screwes, bolts nuts etc., complete on the existing metal/PVC box. (P. No.5/ I.No.3.5)PWD Electrical SR 22-23 3 Module ---- etc., complete with all lead | Each | 189.98 | 189.98 | 8.0 | False | None | None | False | None | False | 1519.84 | 0 |
2322457 | 68617 | None | Item 143 | Supplying and fixing superior quality modular switch mounting polycorbonate plate with neceaary supporting back plate with rquired nos. of machine screwes, bolts nuts etc., complete on the existing metal/PVC box. (P. No.5/ I.No.3.5)PWD Electrical SR 22-23 4 Module ---- etc., complete with all lead | Each | 206.5 | 206.5 | 21.0 | False | None | None | False | None | False | 4336.5 | 0 |
2322458 | 68617 | None | Item 144 | Supplying and fixing superior quality modular switch mounting polycorbonate plate with neceaary supporting back plate with rquired nos. of machine screwes, bolts nuts etc., complete on the existing metal/PVC box. (P. No.5/ I.No.3.5)PWD Electrical SR 22-23 6 Module ---- etc., complete with all lead | Each | 276.12 | 276.12 | 16.0 | False | None | None | False | None | False | 4417.92 | 0 |
2322459 | 68617 | None | Item 145 | Supplying and fixing superior quality modular switch mounting polycorbonate plate with neceaary supporting back plate with rquired nos. of machine screwes, bolts nuts etc., complete on the existing metal/PVC box. (P. No.5/ I.No.3.5)PWD Electrical SR 22-23 8 Module ---- etc., complete with all lead | Each | 335.12 | 335.12 | 28.0 | False | None | None | False | None | False | 9383.36 | 0 |
2322460 | 68617 | None | Item 146 | Supplying and fixing superior quality modular switch mounting polycorbonate plate with neceaary supporting back plate with rquired nos. of machine screwes, bolts nuts etc., complete on the existing metal/PVC box. (P. No.5/ I.No.3.5)PWD Electrical SR 22-23 10-12 Module ---- etc., complete with all lead | Each | 405.92 | 405.92 | 12.0 | False | None | None | False | None | False | 4871.04 | 0 |
2322461 | 68617 | None | Item 147 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per 3854 and IS 1293. (P. No.5/ I.No.3.6)PWD Electrical SR 22-23 6A one way. ---- etc., complete with all lead | Each | 120.36 | 120.36 | 383.0 | False | None | None | False | None | False | 46097.88 | 0 |
2322462 | 68617 | None | Item 148 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per 3854 and IS 1293. (P. No.5/ I.No.3.6)PWD Electrical SR 22-23 6A two way.switch ---- etc., complete with all lead | Each | 195.88 | 195.88 | 14.0 | False | None | None | False | None | False | 2742.32 | 0 |
2322463 | 68617 | None | Item 149 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per 3854 and IS 1293. (P. No.5/ I.No.3.6)PWD Electrical SR 22-23 6A Three way socket. ---- etc., complete with all lead | Each | 201.78 | 201.78 | 105.0 | False | None | None | False | None | False | 21186.9 | 0 |
2322464 | 68617 | None | Item 150 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per 3854 and IS 1293. (P. No.5/ I.No.3.6)PWD Electrical SR 22-23 Stepped Fan Regulator. ---- etc., complete with all lead | Each | 421.26 | 421.26 | 30.0 | False | None | None | False | None | False | 12637.8 | 0 |
2322465 | 68617 | None | Item 151 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per 3854 and IS 1293. (P. No.5/ I.No.3.6)PWD Electrical SR 22-23 16Amps one way switch ---- etc., complete with all lead | Each | 212.4 | 212.4 | 6.0 | False | None | None | False | None | False | 1274.4 | 0 |
2322466 | 68617 | None | Item 152 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per 3854 and IS 1293. (P. No.5/ I.No.3.6)PWD Electrical SR 22-23 6Amps Bell push ---- etc., complete with all lead | Each | 208.86 | 208.86 | 1.0 | False | None | None | False | None | False | 208.86 | 0 |
2322467 | 68617 | None | Item 153 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per 3854 and IS 1293. (P. No.5/ I.No.3.6)PWD Electrical SR 22-23 32Amps DP switch ---- etc., complete with all lead | Each | 384.68 | 384.68 | 28.0 | False | None | None | False | None | False | 10771.04 | 0 |
2322468 | 68617 | None | Item 154 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per 3854 and IS 1293. (P. No.5/ I.No.3.6)PWD Electrical SR 22-23 6/16Amps universal socket ---- etc., complete with all lead | Each | 278.48 | 278.48 | 28.0 | False | None | None | False | None | False | 7797.44 | 0 |
2322469 | 68617 | None | Item 155 | Supplying and fixing/replacing of 6/16/32Amps electrical accessories on existing switch board. (P. No.6/ I.No.3.14) PWD Electrical SR 22-23 6Amps Bakelite ceiling rose ---- etc., complete with all lead | No | 92.04 | 92.04 | 10.0 | False | None | None | False | None | False | 920.4 | 0 |
2322470 | 68617 | None | Item 156 | Supplying and fixing/replacing of 6/16/32Amps electrical accessories on existing switch board. (P. No.6/ I.No.3.14) PWD Electrical SR 22-23 6 Amps pendant holder ---- etc., complete with all lead | No | 83.78 | 83.78 | 40.0 | False | None | None | False | None | False | 3351.2 | 0 |
2322471 | 68617 | None | Item 157 | Supplying 4mm thick plastic sheet with necessary nitches for fixing switches regulators etc., and fixing on existing wooden or metal box using N.F. screws.(P. No.6/ I.No.3.8) PWD Electrical SR 22-23 ---- etc., complete with all lead | Sq CM | 0.48 | 0.48 | 1000.0 | False | None | None | False | None | False | 480.0 | 0 |
2322472 | 68617 | None | Item 158 | supplying 4mm thick white plastic plate and covering for junction boxes or size ... mm conduit using necessary machine screws. (P. No.6/ I.No.3.10) PWD Electrical SR 22-23 80/90mm ---- etc., complete with all lead | Each | 17.7 | 17.7 | 10.0 | False | None | None | False | None | False | 177.0 | 0 |
2322473 | 68617 | None | Item 159 | supplying 4mm thick white plastic plate and covering for junction boxes or size ... mm conduit using necessary machine screws. (P. No.6/ I.No.3.10) PWD Electrical SR 22-23 110mm ---- etc., complete with all lead | Each | 24.78 | 24.78 | 10.0 | False | None | None | False | None | False | 247.8 | 0 |
2322474 | 68617 | None | Item 160 | Supplying of on load change over switches 4 poles,AC-23 Aduty 415V, 50Hz, AC Supply.open execution (P.No.11/.I.No.5.11) PWD Electrical SR 22-23 125 Amps ---- etc., complete with all lead | Each | 12184.68 | 12184.68 | 1.0 | False | None | None | False | None | False | 12184.68 | 0 |
2322475 | 68617 | None | Item 161 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. (P.No.12/.I.No.5.14) PWD Electrical SR 22-23 FOUR POLE 100Amps25kA. ---- etc., complete with all lead | Each | 7181.48 | 7181.48 | 1.0 | False | None | None | False | None | False | 7181.48 | 0 |
2322476 | 68617 | None | Item 162 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. (P.No.12/.I.No.5.14) PWD Electrical SR 22-23 FOUR POLE 125Amps25kA. ---- etc., complete with all lead | Each | 10145.64 | 10145.64 | 3.0 | False | None | None | False | None | False | 30436.92 | 0 |
2322477 | 68617 | None | Item 163 | Supplying and fixing of Shunt trip suitable for MCCB.CBCT. (P.No.12/.I.No.5.15)PWD Electrical SR 22-23 ---- etc., complete with all lead | Each | 2009.54 | 2009.54 | 1.0 | False | None | None | False | None | False | 2009.54 | 0 |
2322478 | 68617 | None | Item 164 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C type curve indicator on/off energy cross 3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.(P.No.13/.I.No.5.17)PWD Electrical SR 22-23
6-32Amps DP ---- etc., complete with all lead | Each | 872.02 | 872.02 | 10.0 | False | None | None | False | None | False | 8720.2 | 0 |
2322479 | 68617 | None | Item 165 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C type curve indicator on/off energy cross 3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.(P.No.13/.I.No.5.17)PWD Electrical SR 22-23
50-63Amps DP ---- etc., complete with all lead | Each | 1300.36 | 1300.36 | 6.0 | False | None | None | False | None | False | 7802.16 | 0 |
2322480 | 68617 | None | Item 166 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C type curve indicator on/off energy cross 3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.(P.No.13/.I.No.5.17)PWD Electrical SR 22-23
6-32Amps TPN ---- etc., complete with all lead | Each | 2026.06 | 2026.06 | 8.0 | False | None | None | False | None | False | 16208.48 | 0 |
2322481 | 68617 | None | Item 167 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C type curve indicator on/off energy cross 3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.(P.No.13/.I.No.5.17)PWD Electrical SR 22-23
50-63Amps TPN ---- etc., complete with all lead | Each | 3643.84 | 3643.84 | 6.0 | False | None | None | False | None | False | 21863.04 | 0 |
2322482 | 68617 | None | Item 168 | Supplying and fixing regular MCB distribution boards on wall / woodboard/flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting etc., made out of 14 SWG MS enclosures. .(P.No.13/.I.No.5.18)PWD Electrical SR 22-23 II Double Door 12WaySP&N ---- etc., complete with all lead | Each | 2748.22 | 2748.22 | 4.0 | False | None | None | False | None | False | 10992.88 | 0 |
2322483 | 68617 | None | Item 169 | Supplying and fixing regular MCB distribution boards on wall / woodboard/flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting etc., made out of 14 SWG MS enclosures. .(P.No.13/.I.No.5.18)PWD Electrical SR 22-23 III - Double Door 6WayTP &N ---- etc., complete with all lead | Each | 5829.2 | 5829.2 | 2.0 | False | None | None | False | None | False | 11658.4 | 0 |
2322484 | 68617 | None | Item 170 | Supplying,fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50Hz AC with latest micro controller based, digital read out of percentage leakage current, programmable delay/auto/manualre set facility suitable to mount on DIN rail/ flush mounting on panel board. ---- etc., complete with all lead | Each | 10920.9 | 10920.9 | 1.0 | False | None | None | False | None | False | 10920.9 | 0 |
2322485 | 68617 | None | Item 171 | Supplying and fixing Electronic Trivector Meter (ETV) suitable for operation LT operation and -CT operated meter in polycarbonate body in class 0.5 accuracy as per IS 14697 and completely wired..(P.No.14/.I.No.5.31) PWD Electrical SR 22-23 ---- etc., complete with all lead | Each | 5180.2 | 5180.2 | 1.0 | False | None | None | False | None | False | 5180.2 | 0 |
2322486 | 68617 | None | Item 172 | Supplying of multi function digital Meter three line back light LCD type display of voltage, Current, frequency.Power, power factor, KVA, KWH.KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required.with communication port and class 0.5s accuracy.(P.No.14/.I.No.5.33) PWD Electrical SR 22-23 ---- etc., complete with all lead | Each | 10991.7 | 10991.7 | 2.0 | False | None | None | False | None | False | 21983.4 | 0 |
2322487 | 68617 | None | Item 173 | Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accurecy with tape wound . (P.No.14/.I.No.5.34) PWD Electrical SR 22-23 ---- etc., complete with all lead | Each | 663.16 | 663.16 | 6.0 | False | None | None | False | None | False | 3978.96 | 0 |
2322488 | 68617 | None | Item 174 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C. (P.No.14/.I.No.5.38) PWD Electrical SR 22-23 ---- etc., complete with all lead | Each | 607.7 | 607.7 | 12.0 | False | None | None | False | None | False | 7292.4 | 0 |
2322489 | 68617 | None | Item 175 | Supplying.........amps rated 3phase with neutral bus bar using requiemed capacity electrolyticaluminium strips covered with heat shrinkable couloured PVC sleeve, mounted on phenolic/FRP/DMC insulator whcih are mounted on powder coated 40x6mm M.S.tlat frame work in existing panel board.The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary botls,nuts and washers etc., complete. (P.No.15/.I.No.5.40) PWD Electrical SR 22-23 250Arnps 4x30x10mm Alluminium Strips ---- etc., complete with all lead | Rmtr | 4053.3 | 4053.3 | 4.0 | False | None | None | False | None | False | 16213.2 | 0 |
2322490 | 68617 | None | Item 176 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron., and M.S. flat... with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.(P.No.15/.I.No.5.41) PWD Electrical SR 22-23 50x50x6mm ---- etc., complete with all lead | Rmtr | 466.1 | 466.1 | 15.0 | False | None | None | False | None | False | 6991.5 | 0 |
2322491 | 68617 | None | Item 177 | Fabricating supplying and mounting MS box made out ... SWG suitable for floor/wall mounting, fully weatherproof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete. ((P.No.15/.I.No.5.42) PWD Electrical SR 22-23 14SWG ---- etc., complete with all lead | Sq CM | 0.59 | 0.59 | 135000.0 | False | None | None | False | None | False | 79650.0 | 0 |
2322492 | 68617 | None | Item 178 | Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete..(P.No.22/.I.No.6.2) PWD Electrical SR 22-23 12" Sweep (300mm) ---- etc., complete with all lead | Each | 3503.42 | 3503.42 | 4.0 | False | None | None | False | None | False | 14013.68 | 0 |
2322493 | 68617 | None | Item 179 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system.(.(P.No.16/.I.No.5.47) PWD Electrical SR 22-23 48" Sweep (1200mm) Regular model ---- etc., complete with all lead | Each | 3521.12 | 3521.12 | 32.0 | False | None | None | False | None | False | 112675.84 | 0 |
2322494 | 68617 | None | Item 180 | Supplying wall mounting fan suitable to operate at single- phase 230v AC. supply..(P.No.23/.I.No.6.5) PWD Electrical SR 22-23 300mm Sweep ---- etc., complete with all lead | Each | 2940.56 | 2940.56 | 2.0 | False | None | None | False | None | False | 5881.12 | 0 |
2322495 | 68617 | None | Item 181 | Supplying and drawing UTP-CAT 6E LAN cable.(P.No.27/.I.No.8.1) PWD Electrical SR 22-23 ---- etc., complete with all lead | Tonne | 44.84 | 44.84 | 110.0 | False | None | None | False | None | False | 4932.4 | 0 |
2322496 | 68617 | None | Item 182 | Supplying & Fixing of switch mounting rack with power manager & Cable manager..(P.No.28/.I.No.8.4) PWD Electrical SR 22-23 4U with 450mm depth ---- etc., complete with all lead | Each | 5772.56 | 5772.56 | 1.0 | False | None | None | False | None | False | 5772.56 | 0 |
2322497 | 68617 | None | Item 183 | Supplying fixing of Network Switches 8 port 10/100 Switch ---- etc., complete with all lead | Each | 1239.0 | 1239.0 | 1.0 | False | None | None | False | None | False | 1239.0 | 0 |
2322498 | 68617 | None | Item 184 | Supplying & fixing of I/O socket with back box.(P.No.28/.I.No.8.10) PWD Electrical SR 22-23 Single I/O ---- etc., complete with all lead | Each | 578.2 | 578.2 | 5.0 | False | None | None | False | None | False | 2891.0 | 0 |
2322499 | 68617 | None | Item 185 | supplying of ...feet PVC batten integrated LED tube ... Wattts with high quality diffuser with life of 25000 burning hours & 70% lumen maintenance with CRI more than 80 power input 220v-240v @ 50HZ & power factor more than .9 along with CE apporved. 2 years warranty aganist any manufacturing defect working under electrical condition (P. No.34/ I.No.11.3) PWD Electrical SR 2022 -23 LED light fitting 1X4' 20/22 watts ---- etc., complete with all lead | Each | 814.2 | 814.2 | 46.0 | False | None | None | False | None | False | 37453.2 | 0 |
2322500 | 68617 | None | Item 186 | Supplying of recess mounting non integral type ........ LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRI more than 70%. efficacy more than 100 lumen per watt, 120degree beam spread, life more than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF more than 0.95, power loss should less than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition..(P.No.34/.I.No.11.6) PWD Electrical SR 22-23 LED modular down light 1 'x1' 34 -22watts ---- etc., complete with all lead | Nos | 4356.56 | 4356.56 | 4.0 | False | None | None | False | None | False | 17426.24 | 0 |
2322501 | 68617 | None | Item 187 | Supplying of recess mounting non integral type ........ LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRI more than 70%. efficacy more than 100 lumen per watt, 120degree beam spread, life more than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF more than 0.95, power loss should less than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition..(P.No.34/.I.No.11.6) PWD Electrical SR 22-23 LED modular down light 2'x2' /1' X 4' 34 -36watt ---- etc., complete with all lead | Nos | 6959.64 | 6959.64 | 4.0 | False | None | None | False | None | False | 27838.56 | 0 |
2322502 | 68617 | None | Item 188 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT more than 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire more than IK08. Power Factor more than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency more than 1301m/w, nominal CRI more than 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source..(P.No.36/.I.No.11.8) PWD Electrical SR 22-23 LED Streetlight 90 Watts ---- etc., complete with all lead | Nos | 10454.8 | 10454.8 | 5.0 | False | None | None | False | None | False | 52274.0 | 0 |
2322503 | 68617 | None | Item 189 | Supplying & fixing of retrofit type - LED bulb ...... W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI more than 70%. efficacy more than 80 lumen per watt, life more than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF more than 0.95, power loss should less than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition..(P.No.38/.I.No.11.11) PWD Electrical SR 22-23 15W, 6500K ---- etc., complete with all lead | Each | 384.68 | 384.68 | 10.0 | False | None | None | False | None | False | 3846.8 | 0 |
2322504 | 68617 | None | Item 190 | Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote.(P.No.39/.I.No.12.2) PWD Electrical SR 22-23 Musical ---- etc., complete with all lead | Each | 512.12 | 512.12 | 1.0 | False | None | None | False | None | False | 512.12 | 0 |
2322505 | 68617 | None | Item 191 | Fixing all types and all capacities fluorescent/false ceiling/spot light/ CFL/LED fittings indoor on the wall /ceiling/rafters/girders using 23/ 0.0076" twin twisted PVC insulated wires, required nos of round blocks and clamps (P.No.45/.I.No.13.7)) On wall/ceiling/Rafter/Girders PWD Electrical SR 2022 ---- etc., complete with all lead | Each | 143.96 | 143.96 | 70.0 | False | None | None | False | None | False | 10077.2 | 0 |
2322506 | 68617 | None | Item 192 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose,
necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.(P.No.46/.I.No.13.10) PWD ellectrical SR 2022 - 23 ---- etc., complete with all lead | Each | 371.7 | 371.7 | 24.0 | False | None | None | False | None | False | 8920.8 | 0 |
2322507 | 68617 | None | Item 193 | Fixing one exhaust fan after making a suitable notch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 A, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.. (P.No.46/.I.No.13.13) PWD Electrical SR 2022 - 23 ---- etc., complete with all lead | Each | 834.26 | 834.26 | 4.0 | False | None | None | False | None | False | 3337.04 | 0 |
2322508 | 68617 | None | Item 194 | Supplying and Fixing........mm dia class A GI pipe bracket upto 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/tubular pole, using suitable clA, bolts, nuts and wiring using suitable capacity wires.(P.No.45/.I.No.13.1) PWD Electrical SR 2022 - 23 Using 32mm dia G.I.Pipe ---- etc., complete with all lead | Each | 1233.1 | 1233.1 | 5.0 | False | None | None | False | None | False | 6165.5 | 0 |
2322509 | 68617 | None | Item 195 | Fixing of ..... A TPST / change over switch / Contactor along with neutral link with screws, bolts, nuts and wiring using required capacity wires and circuit labelling.(P.No.46/.I.No.13.18) PWD Electrical SR 2022 - 23 100A to 250A TPDT/COS ---- etc., complete with all lead | Each | 527.46 | 527.46 | 1.0 | False | None | None | False | None | False | 527.46 | 0 |
2322510 | 68617 | None | Item 196 | RCC Pole - 9 Mtr Long, 145 Kg WL (Dwg No. BESCOM/GM/QS&S/02 Dtd 24.11.2018) as per IS-785 (P.No.01/.I.No.1) BESCOM SR 2021 - 22 PART III ---- etc., complete with all lead | Nos | 8349.68 | 8349.68 | 5.0 | False | None | None | False | None | False | 41748.4 | 0 |
2322511 | 68617 | None | Item 197 | 11 kV, Special 3 Pin Cross Arm - GI (P.No.01/.I.No.14) BESCOM SR 2021 - 22 PART III ---- etc., complete with all lead | Nos | 1358.18 | 1358.18 | 4.0 | False | None | None | False | None | False | 5432.72 | 0 |
2322512 | 68617 | None | Item 198 | LT 4 Pin Cross Arm - GI (P.No.01/.I.No.16) BESCOM SR 2021 - 22 PART III ---- etc., complete with all lead | Nos | 447.22 | 447.22 | 2.0 | False | None | None | False | None | False | 894.44 | 0 |
2322513 | 68617 | None | Item 199 | RCC Pole Clamp - GI (P.No.02/.I.No.32) BESCOM SR 2021 - 22 PART III ---- etc., complete with all lead | Nos | 112.1 | 112.1 | 5.0 | False | None | None | False | None | False | 560.5 | 0 |
2322514 | 68617 | None | Item 200 | Guy Clamp - GI (P.No.01/.I.No.40) BESCOM SR 2021 - 22 PART III ---- etc., complete with all lead | Nos | 135.7 | 135.7 | 2.0 | False | None | None | False | None | False | 271.4 | 0 |
2322515 | 68617 | None | Item 201 | Anchor Rod using 12 mm rounds/Guy Rod - GI (P.No.02/.I.No.43) BESCOM SR 2021 - 22 PART III ---- etc., complete with all lead | Nos | 388.22 | 388.22 | 2.0 | False | None | None | False | None | False | 776.44 | 0 |
2322516 | 68617 | None | Item 202 | GI Fish Plate (P.No.02/.I.No.45) BESCOM SR 2021 - 22 PART III ---- etc., complete with all lead | Nos | 105.02 | 105.02 | 2.0 | False | None | None | False | None | False | 210.04 | 0 |
2322517 | 68617 | None | Item 203 | 11 kV, 5 kN Composite/Polymeric Pin Insulator (24 mm
dia FRP Rod) (P.No.02/.I.No .51) BESCOM SR 2021 - 22 PART III ---- etc., complete with all lead | Nos | 241.9 | 241.9 | 9.0 | False | None | None | False | None | False | 2177.1 | 0 |
2322518 | 68617 | None | Item 204 | 8 Strain Insulator (P.No.02/.I.No .52) BESCOM SR 2021 - 22 PART III ---- etc., complete with all lead | Nos | 31.86 | 31.86 | 8.0 | False | None | None | False | None | False | 254.88 | 0 |
2322519 | 68617 | None | Item 205 | DISC Insulator 45 kN Porcelain (P.No.02/.I.No .54) BESCOM SR 2021 - 22 PART III ---- etc., complete with all lead | Nos | 601.8 | 601.8 | 6.0 | False | None | None | False | None | False | 3610.8 | 0 |
2322520 | 68617 | None | Item 206 | Rabbit ACSR (6/3.35 mm Al + 1/3.35 mm St), Std Wt: 214 Kg/KM (P.No.03/.I.No .61) BESCOM SR 2021 - 22 PART III ---- etc., complete with all lead | Km | 54556.12 | 54556.12 | 0.4 | False | None | None | False | None | False | 21822.448 | 0 |
2322521 | 68617 | None | Item 207 | 7/10 SWG Guy Wire (7/3.251 mm Dia), Std Wt: 680 Kg/KM (P.No.03/.I.No .64) BESCOM SR 2021 - 22 PART III ---- etc., complete with all lead | Tonne | 91126.68 | 91126.68 | 0.025 | False | None | None | False | None | False | 2278.167 | 0 |
2322522 | 68617 | None | Item 208 | 8 SWG GI Wire (4.064 mm Dia), Std Wt: 125 Kg/KM ---- etc., complete with all lead | Tonne | 88547.2 | 88547.2 | 0.03 | False | None | None | False | None | False | 2656.416 | 0 |
2322523 | 68617 | None | Item 209 | Distribution Transformer - 3 Phase, 11kV/433V - Stacked CRGO Core with Oil as per IS-1180 (Part-1): 2014 63 kVA, Aluminum Wdg, Star 2 (5 Star) (P.No.04/.I.No .105) BESCOM SR 2021 - 22 PART III ---- etc., complete with all lead | Nos | 215403.1 | 215403.1 | 1.0 | False | None | None | False | None | False | 215403.1 | 0 |
2322524 | 68617 | None | Item 210 | LT Protection Kit (Dwg No. BESCOM/GM/QS&S/10 Dtd 24.11.2018) (P.No.05/.I.No .151) BESCOM SR 2021 - 22 PART III ---- etc., complete with all lead | Nos | 2387.14 | 2387.14 | 1.0 | False | None | None | False | None | False | 2387.14 | 0 |
2322525 | 68617 | None | Item 211 | LT Distribution Box for 100 kVA DTC with MCCB's (Sheet Metal)
(Dwg No. BESCOM/GM/QS&S/58 Dtd 24.11.2018 (P.No.06/.I.No .152) BESCOM SR 2021 - 22 PART III ---- etc., complete with all lead | Nos | 26920.52 | 26920.52 | 1.0 | False | None | None | False | None | False | 26920.52 | 0 |
2322526 | 68617 | None | Item 212 | 9 kV, 5 kA Lightning Arrester Metal Oxide Ceramic type with GROUND DISCONNECTOR (Dwg No. BESCOM/GM/QS&S/26 Dtd 24.10.2007) (P.No.06/.I.No .152) BESCOM SR 2021 - 22 PART III ---- etc., complete with all lead | Set | 1085.6 | 1085.6 | 1.0 | False | None | None | False | None | False | 1085.6 | 0 |
2322527 | 68617 | None | Item 213 | 11 kV, HG Fuse Unit with Solid Core Insulator (Dwg No. BESCOM/GM/QS&S/21 Dtd 24.11.2018) (P.No.06/.I.No .157) BESCOM SR 2021 - 22 PART III ---- etc., complete with all lead | Set | 1261.42 | 1261.42 | 1.0 | False | None | None | False | None | False | 1261.42 | 0 |
2322528 | 68617 | None | Item 214 | Double Pole TC Set for erection of Transformer on RCC/PSCC 9 Mtr Long
Poles as per IS-1977 For 25/63/100 kVA 4/5 Star Rated Transformer on RCC Pole - 9 Mtr Long, 145 Kg WL - MS (P.No.06/.I.No .160) BESCOM SR 2021 - 22 PART III ---- etc., complete with all lead | Set | 20725.52 | 20725.52 | 1.0 | False | None | None | False | None | False | 20725.52 | 0 |
2322529 | 68617 | None | Item 215 | 11 kV, 200 Amps Single Break GOS (Dwg No. BESCOM/GM/QS&S/23 Dtd 24.11.2018) (P.No.08/.I.No .184) BESCOM SR 2021 - 22 PART III ---- etc., complete with all lead | Set | 11151.0 | 11151.0 | 1.0 | False | None | None | False | None | False | 11151.0 | 0 |
2322530 | 68617 | None | Item 216 | H - Frame Set for fixing 11 kV, 200 Amps Single Break GOS - (For DP structure for providing New GOS for sectionalisation) - GI (P.No.08/.I.No .188) BESCOM SR 2021 - 22 PART III ---- etc., complete with all lead | Set | 7163.78 | 7163.78 | 1.0 | False | None | None | False | None | False | 7163.78 | 0 |
2322531 | 68617 | None | Item 217 | Insulated GOS Operating Rods (P.No.08/.I.No .191) BESCOM SR 2021 - 22 PART III ---- etc., complete with all lead | Nos | 487.34 | 487.34 | 1.0 | False | None | None | False | None | False | 487.34 | 0 |
2322532 | 68617 | None | Item 218 | 11 kV, DOLO Cutout REC Specification (Dwg No. BESCOM/GM/QS&S/20 Dtd 24.11.2018) (P.No.08/.I.No .193) BESCOM SR 2021 - 22 PART III ---- etc., complete with all lead | Set | 5004.38 | 5004.38 | 1.0 | False | None | None | False | None | False | 5004.38 | 0 |
2322533 | 68617 | None | Item 219 | DP Set (2 Pole Strucrure Kit) as per IS-1977 For RCC Pole - 9 Mtr Long, 145KG WL/PSCC Pole - 9 Mtr Long, 300Kg WL - MS (Dwg No. BESCOM/GM/QS&S/35 & 63 Dtd
24.11.2018) (P.No.08/.I.No .194) BESCOM SR 2021 - 22 PART III ---- etc., complete with all lead | Set | 7553.18 | 7553.18 | 1.0 | False | None | None | False | None | False | 7553.18 | 0 |
2322534 | 68617 | None | Item 220 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 (P.No.09/.I.No .32) BESCOM SR 2021 - 22 PART III
16 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm) (P.No.09/.I.No .215) BESCOM SR 2021 - 22 PART III ---- etc., complete with all lead | Km | 167373.56 | 167373.56 | 0.32 | False | None | None | False | None | False | 53559.5392 | 0 |
2322535 | 68617 | None | Item 221 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 (P.No.09/.I.No .32) BESCOM SR 2021 - 22 PART III
35 Sqmm, 3.5 Core, (14 GI Strips - 4 x 0.8 mm) (P.No.09/.I.No .219) BESCOM SR 2021 - 22 PART III ---- etc., complete with all lead | Km | 212215.92 | 212215.92 | 0.2 | False | None | None | False | None | False | 42443.184 | 0 |
2322536 | 68617 | None | Item 222 | Transparent Alkathine tube 19 mm dia, 2 mm thick in coils of 30 Mtr (P.No.17/.I.No .444) BESCOM SR 2021 - 22 PART III ---- etc., complete with all lead | Coil | 610.06 | 610.06 | 1.0 | False | None | None | False | None | False | 610.06 | 0 |
2322537 | 68617 | None | Item 223 | LT 3 Phase, 4 Wire, CT Operated DLMS Complaint ETV Meter-5A, class 0.5s Accuracy (Used for 25 HP/18KW & Above Installations, DTC Metering (P.No.18/.I.No .451) BESCOM SR 2021 - 22 PART III ---- etc., complete with all lead | Nos | 2808.4 | 2808.4 | 1.0 | False | None | None | False | None | False | 2808.4 | 0 |
2322538 | 68617 | None | Item 224 | Supplying .fixing and wiring heavy duty low voltage capacitors conforming to IS 2834, 3 phase, 400/440 volts grade, for power factor improvement of rotating machinerieslike induction motor.(P.No14/.I.No.5.37) ---- etc., complete with all lead | Kvar | 566.4 | 566.4 | 5.0 | False | None | None | False | None | False | 2832.0 | 0 |
2322539 | 68617 | None | Item 225 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff (P.No.09/ .I.No.31.06/) BESCOM SR 20211-22 PART IV 2.5 to 25 Sqmm ---- etc., complete with all lead | Km | 24645.48 | 24645.48 | 0.32 | False | None | None | False | None | False | 7886.5536 | 0 |
2322540 | 68617 | None | Item 226 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff (P.No.09/ .I.No.31.06/) BESCOM SR 20211-22 PART IV 35 sqmm to 95 sqmm ---- etc., complete with all lead | Km | 27903.46 | 27903.46 | 0.2 | False | None | None | False | None | False | 5580.692 | 0 |
2322541 | 68617 | None | Item 227 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes ( (P.No.43/ .I.No.6.17)PWD ELECTRICAL SR 2019-20 1.5 sqmm ---- etc., complete with all lead | Each | 3.54 | 3.54 | 32.0 | False | None | None | False | None | False | 113.28 | 0 |
2322542 | 68617 | None | Item 228 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes ( (P.No.43/ .I.No.6.17)PWD ELECTRICAL SR 2019-20 6 sqmm ---- etc., complete with all lead | Each | 8.26 | 8.26 | 40.0 | False | None | None | False | None | False | 330.4 | 0 |
2322543 | 68617 | None | Item 229 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes ( (P.No.43/ .I.No.6.17)PWD ELECTRICAL SR 2019-20 35 sqmm long barrel ---- etc., complete with all lead | Each | 37.76 | 37.76 | 32.0 | False | None | None | False | None | False | 1208.32 | 0 |
2322544 | 68617 | None | Item 230 | Providing, Laying and Fixing GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing). (P.No.142/ .I.No.1/2.5) WS&UGD works SR 2022 For Medium Duty GI pipe: 40mm dia ---- etc., complete with all lead | Rmtr | 575.84 | 575.84 | 12.0 | False | None | None | False | None | False | 6910.08 | 0 |
2322545 | 68617 | None | Item 231 | Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia. (P.No.164/.I.No. P430A) WS&UGD works SR 2022 ---- etc., complete with all lead | Job | 4425.0 | 4425.0 | 12.0 | False | None | None | False | None | False | 53100.0 | 0 |
2322546 | 68617 | None | Item 232 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required.(P.No.40/.I.No.6.3) PWD Electrical SR 2019-20 25x3mm Gl strip ---- etc., complete with all lead | Mtr | 96.76 | 96.76 | 30.0 | False | None | None | False | None | False | 2902.8 | 0 |
2322547 | 68617 | None | Item 233 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required.(P.No.40/.I.No.6.3) PWD Electrical SR 2019-20 600x600x3mm Copper plate ---- etc., complete with all lead | Each | 8756.78 | 8756.78 | 1.0 | False | None | None | False | None | False | 8756.78 | 0 |
2322548 | 68617 | None | Item 234 | Digging of Pit 1.8 Mtr depth for errection of 9 to 10 Mtr Long Steel/RCC/PSCC supports as per approved Drawing. (P.No.01/.I.No .1.1) BESCOM SR 2021 - 22 PART IV Hard Soil ---- etc., complete with all lead | Per Pit | 1335.76 | 1335.76 | 5.0 | False | None | None | False | None | False | 6678.8 | 0 |
2322549 | 68617 | None | Item 235 | Digging of Pit for GUY SET. (P.No.01/.I.No .1.7) BESCOM SR 2021 - 22 PART IV Hard Soil ---- etc., complete with all lead | Per Pit | 742.22 | 742.22 | 2.0 | False | None | None | False | None | False | 1484.44 | 0 |
2322550 | 68617 | None | Item 236 | Providing cement concrete to Poles and Guy sets with material and labour including necessary curing etc., complete (cost doesnot include excavation) (P.No.01/.I.No .1.8) BESCOM SR 2021 - 22 PART IV Base Concreting with CC 1:4: 8 Pole base for 11/9.5/9/8 Mtr supports (500x650x150mm) ---- etc., complete with all lead | Each | 322.14 | 322.14 | 5.0 | False | None | None | False | None | False | 1610.7 | 0 |
2322551 | 68617 | None | Item 237 | Pole Concreting with CC 1:2:4 (without coping) 9 Mtr support (650x500x1700mm) ---- etc., complete with all lead | Each | 3726.44 | 3726.44 | 5.0 | False | None | None | False | None | False | 18632.2 | 0 |
2322552 | 68617 | None | Item 238 | Erection of RCC/PSCC Pole of 9 to 10 Mtr long in a pit of 1.8 Mtr depth(P.No.02/.I.No .2.02) BESCOM SR 2021 - 22 PART IV ---- etc., complete with all lead | Each | 1313.34 | 1313.34 | 5.0 | False | None | None | False | None | False | 6566.7 | 0 |
2322553 | 68617 | None | Item 239 | Erection of Double Pole Transformer Structure using 9 Mtr Long RCC (145 Kg WL)/PSCC (300 Kg WL) Pole including fixing of Structure Materials, Erection of Poles etc., complete for mounting of Transformer as per approved drawing For 25/63/100 kVA (P.No.02/.I.No .3.01) BESCOM SR 2021 - 22 PART IV ---- etc., complete with all lead | Per Structure | 6755.5 | 6755.5 | 1.0 | False | None | None | False | None | False | 6755.5 | 0 |
2322554 | 68617 | None | Item 240 | Erection of H-Frame. (P.No.02/.I.No .2.09) BESCOM SR 2021 - 22 PART IV ---- etc., complete with all lead | Each | 381.14 | 381.14 | 1.0 | False | None | None | False | None | False | 381.14 | 0 |
2322555 | 68617 | None | Item 241 | Fixing of 4 Pin cross arm with Insulator and Braces fixing(P.No.02/.I.No .5.02) BESCOM SR 2021 - 22 PART IV ---- etc., complete with all lead | Each | 188.8 | 188.8 | 2.0 | False | None | None | False | None | False | 377.6 | 0 |
2322556 | 68617 | None | Item 242 | Fixing of V-Shape/Horizontal cross arm including Single Top Support Brace and Insulator fixing (P.No.02/.I.No .5.03) BESCOM SR 2021 - 22 PART IV ---- etc., complete with all lead | Each | 188.8 | 188.8 | 5.0 | False | None | None | False | None | False | 944.0 | 0 |
2322557 | 68617 | None | Item 243 | Fixing of GUY Set with break insulator making use of 7/3.15 mm (7/10 SWG) galvanised steel wire with turn buckle and anchoring arrangement as per approved drawing. (Excluding excavation of PIT)(P.No.02/.I.No .5.10) BESCOM SR 2021 - 22 PART IV ---- etc., complete with all lead | Each | 313.88 | 313.88 | 2.0 | False | None | None | False | None | False | 627.76 | 0 |
2322558 | 68617 | None | Item 244 | Stringing of conductor Rabbit ACSR, binding of conductor on each insulator and dead ending on strain or disc/strain insulator by means of clamps.(P.No.03/.I.No .5.70) BESCOM SR 2021 - 22 PART IV ---- etc., complete with all lead | Per Km | 3752.4 | 3752.4 | 0.4 | False | None | None | False | None | False | 1500.96 | 0 |
2322559 | 68617 | None | Item 245 | Erection of 25 to 63 kVA Transformer on Transformer Structure .(P.No.03/.I.No .7.01) BESCOM SR 2021 - 22 PART IV ---- etc., complete with all lead | Each | 1407.74 | 1407.74 | 1.0 | False | None | None | False | None | False | 1407.74 | 0 |
2322560 | 68617 | None | Item 246 | Fixing Metering Box for housing the ETV Meter 3 Phase 4 Wire along with CT's, Meter & wiring for DTC 25/63 kVA TC (P.No.04/.I.No .11.01) BESCOM SR 2021 - 22 PART IV ---- etc., complete with all lead | Set | 2296.28 | 2296.28 | 1.0 | False | None | None | False | None | False | 2296.28 | 0 |
2322561 | 68617 | None | Item 247 | Fixing DOLO Cutout/Horn Gap Fuse including fixing of cross arm and wiring(P.No.05/.I.No .13.01) BESCOM SR 2021 - 22 PART IV ---- etc., complete with all lead | Each | 279.66 | 279.66 | 3.0 | False | None | None | False | None | False | 838.98 | 0 |
2322562 | 68617 | None | Item 248 | Fixing of GOS including wiring (11 kV Single Break 200 Amps) (P.No.05/.I.No .13.02) BESCOM SR 2021 - 22 PART IV ---- etc., complete with all lead | Each | 1302.72 | 1302.72 | 1.0 | False | None | None | False | None | False | 1302.72 | 0 |
2322563 | 68617 | None | Item 249 | Fixing of 3 Nos Lightning Arrestor including wiring (P.No.05/.I.No .13.07) BESCOM SR 2021 - 22 PART IV ---- etc., complete with all lead | Set | 106.2 | 106.2 | 1.0 | False | None | None | False | None | False | 106.2 | 0 |
2322564 | 68617 | None | Item 250 | Wiring of 1 Circuit of LT Wiring for for 25/63/100 kVA DTC to the existing LT protection Kit/Distribution Box via metering box. (includes fixing of necessary supports like 2 Pin cross arm, Spacer etc) (P.No.06/.I.No .15.04) BESCOM SR 2021 - 22 PART IV ---- etc., complete with all lead | Set | 848.42 | 848.42 | 1.0 | False | None | None | False | None | False | 848.42 | 0 |
2322565 | 68617 | None | Item 251 | Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr, Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed. (P.No.08/.I.No .29.03) BESCOM SR 2021 - 22 PART IV in Hard soil ---- etc., complete with all lead | Cum | 459.02 | 459.02 | 125.0 | False | None | None | False | None | False | 57377.5 | 0 |
2322566 | 68617 | None | Item 252 | Refilling the cable trenches with selected available earth from trench excavation including watering, consolidation in layers of 15 cm. Thickness including depositing of the surplus earth with a lead of 200 Mtr (P.No.08/.I.No .29.07) BESCOM SR 2021 - 22 PART IV in Hard soil ---- etc., complete with all lead | Cum | 68.44 | 68.44 | 25.0 | False | None | None | False | None | False | 1711.0 | 0 |
2322567 | 68617 | None | Item 253 | Supplying, installing, testing and commissioning of Diesel Generator set with following specifications. Power rating as per standard reference condition as per-BS 5514/ISO 3046/ ISO 8528 & IS 1002/ISO 3046 Generator set specifications. Engine: Diesel generating set are rated at 1500RPM and conform to ISO 8528 specifications. The engines are radiator cooled, four stroke and multi cylinder, conforming to ISO 3046. The scope of supply includes: Electrical starter motor12V DC Battery charging alternator, Bosch fuel system with mechanical governor, A1 Class. Spin-on lube oil filter, Spin-on dual fuel filter with water separator, Turbocharger, Charge air cooler, Silencer (Hospital grade), Dry type air cleaner, Shutoff coil, Flywheel and flywheel housing, First fill of lube oil and coolant, Safety for low lube oil pressure, Safety for high water temperature, Permissible overload of 10% for one hour in 12 hours of operation Capacity of Fuel Tank: Fuel tank suitable for 8 hours of operation Alternator: Alternator is suitable for operation at 1500 RPM, 415 Volts, 0.8 pf (lag) suitable for 50 Hz, 3 phase, 4 wire systems, conforming to IS/IEC 60034-1. The Alternator is brush less type, screen protected, revolving field, self excited, self regulated through an AVR. The alternator shall have plus or minus 1.0% Voltage regulation (max) in static conditions- IP: 23 protections with insulation class F&H. Mounting arrangement: Engine and alternator are mounted on a common MS fabricated base frame with AVM pads. Control Panel: The control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish. The control panel consists of the following parts:- PS0500 Controller, Aluminium bus bars with suitable capacity within/outgoing terminals, Indicating lamps for 'Load On' and 'Set Running', Instrument fuses duly wired and ferruled, MCCB of suitable rating with overload and short circuit protections. Genset Controller: microprocessor based generator set monitoring and control system. The control provides a simple operator interface to the generator set, manual and remote start/ stop control, shutdown fault indication, and an LCD hour counter. The integration of all functions into a single control system provides enhanced reliability and performance compared to conventional generator set control systems. This control has been designed and tested to meet harsh environment in which gensets are typically applied. Features, Functions, protections 16 character x 2 line alphanumeric LCD display with LED Backlight Operator interface, Provide a record of most recent fault conditions. Fault history stored in the control non volatile memory, Provide Alternator Data. Voltage (1 ph or 3 ph line to line and line to neutral voltage, Current (1 ph or 3 ph), kVA (3 ph and total), Frequency, Provide Engine Data, Starting battery voltage, Engine running hours, Engine Temp, Engine oil pressure, Control includes provision for Service adjustment and calibration of DG control functions, Voltage, frequency selection, Configurable input and output set up, Meter calibration, Engine controls, Power Start operates on 12 VDC batteries,-Auto start mode accepts a ground signal from remote devices to automatically start the DG set The remote start will also wake up the control system from sleep mode. Engine Starting -The control system supports automatic engine starting, Primary and back up start disconnects are achieved by battery charging alternator feedback or main alternator output frequency. Controller provide configurable time delay of 0-300 sees to start after remote start signal and time delay of 0-600secs prior to shut down after stop signal. Sleep mode increase battery life. : etc., : 25 KVA/20kw ---- etc., complete with all lead | Set | 532299.18 | 532299.18 | 1.0 | False | None | None | False | None | False | 532299.18 | 0 |
2322568 | 68617 | None | Item 254 | Supplying, installation, testing and commissioning of solar hot water heater comprising of high quality Evacuated Glass Tube (EGT) with absorber coating collector of size 58 x 1800 mm. Inner tank Material-Stainless steel 304-L Grade with Aluminium Stucco cladding made of High quality PUF insulation to minimizes heat loss and hold water Temperature upto 72 Hrs...with appropriate capacity electrical back up arrangement excluding inlet and out let pipes. Fitted with Sacrificial Anode (P.No.27/.I.No.7.4) PWD Electrical SR 22-23 300 Liter capacity- 29 nos Tubes ---- etc., complete with all lead | Each | 60803.04 | 60803.04 | 1.0 | False | None | None | False | None | False | 60803.04 | 0 |
2322569 | 68617 | None | Item 255 | Supplying,erecting,testing&commissioningofOFF- LINEUPSsystemsuitableforoperationon230V,50Hz,A/Csupply,withallaccessories complete and Excluding batteries and wiring complete. 5 kVA OFF LINE UPS ---- etc., complete with all lead | Each | 47079.64 | 47079.64 | 1.0 | False | None | None | False | None | False | 47079.64 | 0 |
2322570 | 68617 | None | Item 256 | Supplying,erecting,testing&commissioningofOFF- LINEUPSsystemsuitableforoperationon230V,50Hz,A/Csupply,withallaccessories complete and Excluding batteries and wiring complete. 1.5 Ton capacity ---- etc., complete with all lead | Each | 56265.94 | 56265.94 | 2.0 | False | None | None | False | None | False | 112531.88 | 0 |
2322571 | 68617 | None | Item 257 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. TV/Telephone socket ---- etc., complete with all lead | Each | 184.08 | 184.08 | 4.0 | False | None | None | False | None | False | 736.32 | 0 |
2322572 | 68617 | None | Item 258 | Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Dong Bell ---- etc., complete with all lead | Each | 290.28 | 290.28 | 2.0 | False | None | None | False | None | False | 580.56 | 0 |
2322573 | 68617 | None | Item 259 | Supplying and Fixing Metal Fan Box with Round Hook. ---- etc., complete with all lead | Nos | 138.06 | 138.06 | 10.0 | False | None | None | False | None | False | 1380.6 | 0 |
2322574 | 68617 | None | Item 260 | Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 32mm dia 2.5mm thick ---- etc., complete with all lead | Mtr | 121.54 | 121.54 | 50.0 | False | None | None | False | None | False | 6077.0 | 0 |
2322575 | 68617 | None | Item 261 | Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 32mm dia 2.5mm thick ---- etc., complete with all lead | Mtr | 116.82 | 116.82 | 20.0 | False | None | None | False | None | False | 2336.4 | 0 |
2322576 | 68617 | None | Item 262 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper with low conductor resistance single core cable in open or concealed system of wiring with specified IS-694:1990 & comfirming to 6 sqmm ---- etc., complete with all lead | Mtr | 108.56 | 108.56 | 250.0 | False | None | None | False | None | False | 27140.0 | 0 |
2322577 | 68617 | None | Item 263 | Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure Double Door 8 Way SP & N ---- etc., complete with all lead | Each | 2187.72 | 2187.72 | 1.0 | False | None | None | False | None | False | 2187.72 | 0 |
2322578 | 68617 | None | Item 264 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32A SP ---- etc., complete with all lead | Each | 489.7 | 489.7 | 26.0 | False | None | None | False | None | False | 12732.2 | 0 |
2322579 | 68617 | None | Item 265 | Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board 16-25 A 2 pole ---- etc., complete with all lead | Each | 5046.86 | 5046.86 | 3.0 | False | None | None | False | None | False | 15140.58 | 0 |
2322580 | 68617 | None | Item 266 | Rod type of earthing using 40 mm Dia, 3 Mtr long MS rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal & connected to equipment ground terminal using PVC Al wire as specified. ( Item No 51.04, SL No 392 ESCOMs SR 2023-24) ---- etc., complete with all lead | Nos | 2562.96 | 2562.96 | 2.0 | False | None | None | False | None | False | 5125.92 | 0 |
2322581 | 68617 | None | Item 267 | Bentonite clay slurry for earthing in 50 Kg Bag ( Item No 54.05, SL No 393 ESCOMs SR 2023-24) ---- etc., complete with all lead | Bag | 434.24 | 434.24 | 1.0 | False | None | None | False | None | False | 434.24 | 0 |
2322582 | 68617 | None | Item 268 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required 25x3mm GI strip .(Item No 6.3.1 Electrical SR 2019-20) ---- etc., complete with all lead | Mtr | 88.5 | 88.5 | 30.0 | False | None | None | False | None | False | 2655.0 | 0 |
2322583 | 68617 | None | Item 269 | Supplying and drawing PVC flexible one pair telepone unarmoured tinned copper cable. (91/11.2) 2 Pair ---- etc., complete with all lead | Mtr | 24.78 | 24.78 | 50.0 | False | None | None | False | None | False | 1239.0 | 0 |
2322584 | 68617 | None | Item 270 | Supplying and drawing PVC insulated gas injected physical foam jelly flooded co-axial TV cable.RG-6. ---- etc., complete with all lead | Rmtr | 51.92 | 51.92 | 50.0 | False | None | None | False | None | False | 2596.0 | 0 |
2322585 | 68617 | None | Item 271 | Supply of round/square recess/surface mounted rolling type LED Down light with .......W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI more than 80. Power Input: 220-240V @ 50/60Hz & Power factor more than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10-12W ---- etc., complete with all lead | Each | 1044.3 | 1044.3 | 16.0 | False | None | None | False | None | False | 16708.8 | 0 |
2322586 | 68617 | None | Item 272 | Supplying & fixing of retrofit type - LED bulb.......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI more than 70%. efficacy more than 80 lumen per watt, life more than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF more than 0.95, power loss should less than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7 W, 6500K ---- etc., complete with all lead | Each | 175.82 | 175.82 | 14.0 | False | None | None | False | None | False | 2461.48 | 0 |
2322587 | 68617 | None | Item 273 | Supplying & fixing of retrofit type - LED bulb.......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI more than 70%. efficacy more than 80 lumen per watt, life more than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF more than 0.95, power loss should less than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 12 W, 6500K ---- etc., complete with all lead | Each | 317.42 | 317.42 | 8.0 | False | None | None | False | None | False | 2539.36 | 0 |
2322588 | 68617 | None | Item 274 | Supplying & fixing of retrofit type - LED bulb.......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI more than 70%. efficacy more than 80 lumen per watt, life more than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF more than 0.95, power loss should less than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 18 W, 6500K ---- etc., complete with all lead | Each | 502.68 | 502.68 | 6.0 | False | None | None | False | None | False | 3016.08 | 0 |
2322589 | 68617 | None | Item 275 | Supplying & Fixing of Special Type pigmy and candle lamp. Operating voltage range from 180V to 265V, 50Hz AC power Supply ---- etc., complete with all lead | Nos | 61.36 | 61.36 | 6.0 | False | None | None | False | None | False | 368.16 | 0 |
2322590 | 68617 | None | Item 276 | Supplying & Fixing of 70-150 Watts lamp holder 2 Pin ---- etc., complete with all lead | Each | 74.34 | 74.34 | 34.0 | False | None | None | False | None | False | 2527.56 | 0 |
2322591 | 68617 | None | Item 277 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT more than 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire more than IK08. Power Factor more than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency more than 130lm/w, nominal CRI more than 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 25watts ---- etc., complete with all lead | Nos | 2861.5 | 2861.5 | 2.0 | False | None | None | False | None | False | 5723.0 | 0 |
2322592 | 68617 | None | Item 278 | Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. ---- etc., complete with all lead | Each | 1760.56 | 1760.56 | 6.0 | False | None | None | False | None | False | 10563.36 | 0 |
2322593 | 68617 | None | Item 279 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. ---- etc., complete with all lead | Each | 201.78 | 201.78 | 10.0 | False | None | None | False | None | False | 2017.8 | 0 |
2322594 | 68617 | None | Item 280 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. ---- etc., complete with all lead | Each | 834.26 | 834.26 | 6.0 | False | None | None | False | None | False | 5005.56 | 0 |
2322595 | 68617 | None | Item 281 | Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. Length ---- etc., complete with all lead | Each | 1723.98 | 1723.98 | 2.0 | False | None | None | False | None | False | 3447.96 | 0 |
2322596 | 68617 | None | Item 282 | Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. ---- etc., complete with all lead | Each | 191.16 | 191.16 | 2.0 | False | None | None | False | None | False | 382.32 | 0 |
2322597 | 68617 | None | Item 283 | Fabricating supplying and mounting MS box made out....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 16SWG ---- etc., complete with all lead | Sq CM | 0.51 | 0.51 | 96000.0 | False | None | None | False | None | False | 48960.0 | 0 |
2322598 | 68617 | None | Item 284 | Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 100Amps 4x30x6mm Aluminum Strips ---- etc., complete with all lead | Mtr | 2908.7 | 2908.7 | 5.0 | False | None | None | False | None | False | 14543.5 | 0 |
2322599 | 68617 | None | Item 285 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- etc., complete with all lead | Mtr | 359.9 | 359.9 | 5.0 | False | None | None | False | None | False | 1799.5 | 0 |
2322600 | 68617 | None | Item 286 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., complete with all lead | Mtr | 892.08 | 892.08 | 5.0 | False | None | None | False | None | False | 4460.4 | 0 |
2322601 | 68617 | None | Item 287 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR POLE 100 A 25 kA ---- etc., complete with all lead | Each | 10014.66 | 10014.66 | 1.0 | False | None | None | False | None | False | 10014.66 | 0 |
2322602 | 68617 | None | Item 288 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 40 A TPN ---- etc., complete with all lead | Each | 3591.92 | 3591.92 | 1.0 | False | None | None | False | None | False | 3591.92 | 0 |
2322603 | 68617 | None | Item 289 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers 32 A ---- etc., complete with all lead | Each | 284.38 | 284.38 | 4.0 | False | None | None | False | None | False | 1137.52 | 0 |
2322604 | 68617 | None | Item 290 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers 63 A ---- etc., complete with all lead | Each | 473.18 | 473.18 | 1.0 | False | None | None | False | None | False | 473.18 | 0 |
2322605 | 68617 | None | Item 291 | Supplying, fixing and wiring electronic 5 to 20Amps single phase Class-1 Accuracy with Temper Proof Energy Meter ---- etc., complete with all lead | Each | 1628.4 | 1628.4 | 3.0 | False | None | None | False | None | False | 4885.2 | 0 |
2322606 | 68617 | None | Item 292 | Supplying ...litres capacity vertical/horizontal type wall mounting Electrical water heater with 22 SWG copper/SS sheet metal inner Container tinned inside and anticorrosive paint outside and 20 SWG M.S. sheet metal outer cover filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate .2KW capacity element with a neon indicator fitted with 20A capacity 25 to 85 degree Centigrade range thermostat. The water heater shall completely be wired with 40/0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting. 25Litres ---- etc., complete with all lead | Each | 12085.56 | 12085.56 | 2.0 | False | None | None | False | None | False | 24171.12 | 0 |
2322607 | 68617 | None | Item 293 | Supplying, installation, testing and commissioning of solar hot water heater comprising of solar Flat Plate Collector (FPC) of size 2120x1040x100mm and stainless steel hot water storage tank with stainless steel heat exchanger absorber made of copper sheet and copper tube of following capacity aluminium box collector with appropriate capacity electrical back up arrangement excluding inlet and out let pipes. SS Model with 100mm thick of 48Kg/M3density Rock wool insulation with 22SWG Aluminium cladding. 200 L Capacity ---- etc., complete with all lead | Each | 55358.52 | 55358.52 | 2.0 | False | None | None | False | None | False | 110717.04 | 0 |
2322608 | 68617 | None | Item 294 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (P.No.82, I.No. 11.16.1 of PWD SR 2023-24 Vol-2) ---- etc., complete with all lead | Kg | 160.48 | 160.48 | 1020.156 | False | None | None | False | None | False | 163714.63488 | 0 |
2322609 | 68617 | None | Item 295 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal,complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. :(P.No.26, I.No. 7.38 of PWD SR 2023-24 Vol-2) ---- etc., complete with all lead | Sqm | 670.24 | 670.24 | 18.816 | False | None | None | False | None | False | 12611.23584 | 0 |
2322610 | 68617 | None | Item 296 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Septic tank ---- etc., complete with all lead | Cum | 7700.77 | 7700.77 | 20.312 | False | None | None | False | None | False | 156418.04024 | 0 |
2322611 | 68617 | None | Item 297 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/ Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. ---- etc., complete with all lead | Sqm | 964.06 | 964.06 | 206.6 | False | None | None | False | None | False | 199174.796 | 0 |
2322612 | 68617 | None | Item 298 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead | Sqm | 417.72 | 417.72 | 253.984 | False | None | None | False | None | False | 106094.19648 | 0 |
2322613 | 68617 | None | Item 299 | C. I Manhole covers 24" x 24" (2018-19 SR) and 610 * 455mm size (38kgs) ---- etc., complete with all lead | Nos | 2500.0 | 2500.0 | 14.0 | False | None | None | False | None | False | 35000.0 | 0 |
2322614 | 68617 | None | Item 300 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work Depth exceeding 1.5 m, but not exceeding 3 m ---- etc., complete with all lead | Cum | 533.36 | 533.36 | 9.984 | False | None | None | False | None | False | 5325.06624 | 0 |
2322615 | 68617 | None | Item 301 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work Depth exceeding 1.5 m, but not exceeding 3 m ---- etc., complete with all lead | Cum | 546.34 | 546.34 | 1.9968 | False | None | None | False | None | False | 1090.931712 | 0 |
2322616 | 68617 | None | Item 302 | Earth work excavation for FOUNDATION by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work In Hard Rock ( requiring blasting) Depth upto 1.50m ---- etc., complete with all lead | Cum | 653.72 | 653.72 | 2.496 | False | None | None | False | None | False | 1631.68512 | 0 |
2322617 | 68617 | None | Item 303 | Earth work excavation for FOUNDATION by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work In Hard Rock ( requiring blasting) Depth exceeding 1.5 m, but not exceeding 3 m ---- etc., complete with all lead | Cum | 735.14 | 735.14 | 2.496 | False | None | None | False | None | False | 1834.90944 | 0 |
2322618 | 68617 | None | Item 304 | Earth work excavation for FOUNDATION by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work In Hard Rock ( requiring blasting) Depth exceeding 1.5 m, but not exceeding 3 m ---- etc., complete with all lead | Cum | 838.98 | 838.98 | 0.4992 | False | None | None | False | None | False | 418.818816 | 0 |
2322619 | 68617 | None | Item 305 | Loading and Unloading of Stone Boulder/Stone aggregates/Sand/Kankar/Moorum. (Tipper 10 m3) ---- etc., complete with all lead | Cum | 159.3 | 159.3 | 51.8798 | False | None | None | False | None | False | 8264.45214 | 0 |
2322620 | 68617 | None | Item 306 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Beams ---- etc., complete with all lead | Cum | 11214.72 | 11214.72 | 1.9872 | False | None | None | False | None | False | 22285.891584 | 0 |
2322621 | 68617 | None | Item 307 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Beams for Lintel Beam ---- etc., complete with all lead | Cum | 11962.37 | 11962.37 | 0.576 | False | None | None | False | None | False | 6890.32512 | 0 |
2322622 | 68617 | None | Item 308 | Steel Windows with grill for residential buildings
Providing and fixing of windows made of pre-painted steel (base steel as per IS 513 of0.58mm tick galvanized as per IS 277 with zinc of 120 GSM). Primer coated with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with 5-7microns thick alkyd backer. Section for outer frame should be of 48x50mm, centre mullion should be of 48x50mm, section for shutter should be of 48x25mm and fixed glass beading section should be of 12x12mm. Outer frame and mullions to have rebate for glazed shutter and a 20mm provision for guard bars/grills. The sections are to be cut to length mitre joined with corner bracket. Centre mullion is to be fixed with mullion cap. Handle stay 2Nos of stainless steel heavy duty pivot hinges shall be provided for shutter. The window should be panelled with 5mm thick plain fioat glass. Rubber gaskets are to be provided all around the glass. The above frames should be fixed to the concrete/ masonry wall by means of self expanding screws, including 10mm square guard bars with 6" (152.4mm) pitch etc., complete for finished item of work. ---- etc., complete with all lead | Sqm | 4434.44 | 4434.44 | 2.25 | False | None | None | False | None | False | 9977.49 | 0 |
2322623 | 68617 | None | Item 309 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. . (outside) ---- etc., complete with all lead | Sqm | 437.78 | 437.78 | 411.32 | False | None | None | False | None | False | 180067.6696 | 0 |
2322624 | 68617 | None | Item 310 | Geophysical investigation of site for sinking Borewell for supplying drinking water to Habitation either through the Handpump, MWS or PWSS by vertical sounding by adopting veener sounding by adopting veener or schlumbergers's including reconassiance of survey of Geological formation,geophysical investigation of existing ground water in the vicinity quality, quantity and acceptability of the user including the location of site,recommended department of casing pipe required to seal the top and consolidated formation including an extra depth of 1.00Mtr in consolidated formation including an extra depth of drilling required to cover full depth of occupier proposed to trap probable yield and other information required including transportation of instrument and accessories to work site engaging technical personnel labour required etc complete as directed by Engineer in charge ---- etc., complete with all lead | Each | 6239.84 | 6239.84 | 2.0 | False | None | None | False | None | False | 12479.68 | 0 |
2322625 | 68617 | None | Item 311 | Sinking of borewell of 165 mm dia clear using super fast hydraulic of capasity 300 PSIG & above 1100 CMF & above in all strata including over burden upto 20 M fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle crew charges and cost of consumables, etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes) for piped water supply schemes Upto 50 Mtrs ---- etc., complete with all lead | Rmtr | 436.6 | 436.6 | 50.0 | False | None | None | False | None | False | 21830.0 | 0 |
2322626 | 68617 | None | Item 312 | Sinking of borewell of 165 mm dia clear using super fast hydraulic of capasity 300 PSIG & above 1100 CMF & above in all strata including over burden upto 20 M fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle crew charges and cost of consumables, etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes) for piped water supply schemes Above 50 Mtrs and upto 100 Mtr. ---- etc., complete with all lead | Rmtr | 547.52 | 547.52 | 50.0 | False | None | None | False | None | False | 27376.0 | 0 |
2322627 | 68617 | None | Item 313 | Sinking of borewell of 165 mm dia clear using super fast hydraulic of capasity 300 PSIG & above 1100 CMF & above in all strata including over burden upto 20 M fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle crew charges and cost of consumables, etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes) for piped water supply schemes Above100 Mtrs. and upto 150 Mtr. ---- etc., complete with all lead | Rmtr | 581.74 | 581.74 | 50.0 | False | None | None | False | None | False | 29087.0 | 0 |
2322628 | 68617 | None | Item 314 | Sinking of borewell of 165 mm dia clear using super fast hydraulic of capasity 300 PSIG & above 1100 CMF & above in all strata including over burden upto 20 M fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle crew charges and cost of consumables, etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes) for piped water supply schemes Above150 Mtrs. and upto 200 Mtr. ---- etc., complete with all lead | Rmtr | 674.96 | 674.96 | 50.0 | False | None | None | False | None | False | 33748.0 | 0 |
2322629 | 68617 | None | Item 315 | Sinking of borewell of 165 mm dia clear using super fast hydraulic of capasity 300 PSIG & above 1100 CMF & above in all strata including over burden upto 20 M fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle crew charges and cost of consumables, etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes) for piped water supply schemes Above200 Mtrs. and upto 250 Mtr. ---- etc., complete with all lead | Rmtr | 791.78 | 791.78 | 50.0 | False | None | None | False | None | False | 39589.0 | 0 |
2322630 | 68617 | None | Item 316 | Sinking of borewell of 165 mm dia clear using super fast hydraulic of capasity 300 PSIG & above 1100 CMF & above in all strata including over burden upto 20 M fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle crew charges and cost of consumables, etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes) for piped water supply schemes Above250 Mtrs. and upto 300 Mtr. ---- etc., complete with all lead | Rmtr | 873.2 | 873.2 | 35.0 | False | None | None | False | None | False | 30562.0 | 0 |
2322631 | 68617 | None | Item 317 | Supply Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. ---- etc., complete with all lead | Rmtr | 2280.94 | 2280.94 | 25.0 | False | None | None | False | None | False | 57023.5 | 0 |
2322632 | 68617 | None | Item 318 | Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments ---- etc., complete with all lead | Rmtr | 649.0 | 649.0 | 200.0 | False | None | None | False | None | False | 129800.0 | 0 |
2322633 | 68617 | None | Item 319 | Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments ---- etc., complete with all lead | Nos | 177.0 | 177.0 | 1.0 | False | None | None | False | None | False | 177.0 | 0 |
2322634 | 68617 | None | Item 320 | Providing and laying at site of work MS casing caps as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge ---- etc., complete with all lead | Nos | 193.52 | 193.52 | 1.0 | False | None | None | False | None | False | 193.52 | 0 |
2322635 | 68617 | None | Item 321 | Providing NP/CP 50mm dia Waste Unions conforming to ISI specifications and fixing them in position as per directions (Rates includes cost of materials fixtures and conveyance to work spot etc complete) ---- etc., complete with all lead | Nos | 247.8 | 247.8 | 1.0 | False | None | None | False | None | False | 247.8 | 0 |
2322636 | 68617 | None | Item 322 | Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 5.00 HP - 90 LPM @ 110 m = 10 STG Outlet Dia - 2.00" ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete with all lead | Each | 37921.66 | 37921.66 | 1.0 | False | None | None | False | None | False | 37921.66 | 0 |
2322637 | 68617 | None | Item 323 | Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter Up to 3 to 6 HP ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete with all lead | Each | 11269.0 | 11269.0 | 1.0 | False | None | None | False | None | False | 11269.0 | 0 |
2322638 | 68617 | None | Item 324 | Supply and delivery at site 50mm(2”) dia heavy duty CI adopter set complete suitable for uPVC Column pipes for Submersible pumpsets. complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete with all lead | Set | 1829.0 | 1829.0 | 1.0 | False | None | None | False | None | False | 1829.0 | 0 |
2322639 | 68617 | None | Item 325 | Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets.
---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete with all lead | Job | 47.2 | 47.2 | 100.0 | False | None | None | False | None | False | 4720.0 | 0 |
2322640 | 68617 | None | Item 326 | Labour charges for Erection, Electrification and commissioning works of Pump sets including aligning and balancing with all necessary erection of materials and labour including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges, tools and equipments etc., involved in the job. as per specifications, with testing of as per instructions of engineer incharge of work ---- etc., complete with all lead & lift and work to be executed as per the specification and
Engineer-in-charge of the work. ---- etc., complete with all lead | Job | 7670.0 | 7670.0 | 1.0 | False | None | None | False | None | False | 7670.0 | 0 |
2322641 | 68617 | None | Item 327 | Labour charges for Erection of outdoor type panel board and meter board units with all necessary materials and labour tools and equipments including providing cement concrete foundation bed etc., complete. as per specifications, with testing of as per instructions of engineer incharge of work ---- etc., complete with all lead & lift and work to be executed as per the specification and
Engineer-in-charge of the work. ---- etc., complete with all lead | Job | 1593.0 | 1593.0 | 1.0 | False | None | None | False | None | False | 1593.0 | 0 |
2322642 | 68617 | None | Item 328 | Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirmining to table 3 class 5 of IS:8130-1984 and virgin grade PVC insulation and sheathed suitable for working voltage upto 1100Volts as per IS-694:1990 & confirming to GTP of GROUP-A(12/2.10) 3C x 6 mm ---- etc., complete with all lead | Rmtr | 198.24 | 198.24 | 259.0 | False | None | None | False | None | False | 51344.16 | 0 |
2322643 | 68617 | None | Item 329 | Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG ---- etc., complete with all lead | Sq CM | 0.51 | 0.51 | 30000.0 | False | None | None | False | None | False | 15300.0 | 0 |
2322644 | 68617 | None | Item 330 | Supply and Installation I Fixing I Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase I Three Phase Energy Meter in suitable base plate and having a provision for Fuse I MCB cutout with suitable transparent hinged flap opening for operating MCB along with 10 complete tamper proof SEALING facility. (50/6.42) 600mmx600mmx170mm. ---- etc., complete with all lead | Each | 17133.6 | 17133.6 | 1.0 | False | None | None | False | None | False | 17133.6 | 0 |
2322645 | 68617 | None | Item 331 | Supplying and fixing polished wood board made of not less than 15mm thick plank on both sides with planks made out of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws etc. - 500 x 500 x 65 mm (20" x 20" x 2.5") etc., complete as per directions of the Engineer-in-charge ---- etc., complete with all lead | Each | 384.83 | 384.83 | 1.0 | False | None | None | False | None | False | 384.83 | 0 |
2322646 | 68617 | None | Item 332 | Supplying and fixing miniature circuit breakers/Isolators on existing MCB distribution boards using necessary fixing materials and wiring complete as directed by the Engineer-in-charge - 5 to 30 Amps Triple and Neutral ---- etc., complete with all lead | Each | 2023.7 | 2023.7 | 1.0 | False | None | None | False | None | False | 2023.7 | 0 |
2322647 | 68617 | None | Item 333 | Supplying and fixing TPST with neutral link switches rewirable fuse type - Havels / Standard / Indo-Asian Crescent - 30 to 35 Amps, etc., complete as per directions of the Engineer-in-charge ---- etc., complete with all lead | Each | 2124.0 | 2124.0 | 1.0 | False | None | None | False | None | False | 2124.0 | 0 |
2322648 | 68617 | None | Item 334 | Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery (48/6.35) ---- etc., complete with all lead | Each | 472.0 | 472.0 | 1.0 | False | None | None | False | None | False | 472.0 | 0 |
2322649 | 68617 | None | Item 335 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all lead | Cum | 7336.06 | 7336.06 | 2.0 | False | None | None | False | None | False | 14672.12 | 0 |
2322650 | 68617 | None | Item 336 | Removal of Unserviceable Soil with Disposal upto a suitable distance as directed by the Engineer incharge of work ---- etc., complete with all lead | Cum | 100.3 | 100.3 | 12.0 | False | None | None | False | None | False | 1203.6 | 0 |
2322651 | 68617 | None | Item 337 | Loosening, leveling and Compacting original ground supporting
embankment to facilitate placement of first layer of embankment,
scarified to a depth of 150 mm, mixed with water at OMC and
then compacted by rolling so as to achieve minimum dry density
as given in Table 300-2 for embankment construction. ---- etc., complete with all lead | Cum | 123.9 | 123.9 | 36.0 | False | None | None | False | None | False | 4460.4 | 0 |
2322652 | 68617 | None | Item 338 | Construction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401 .For Grading -V Material ---- etc., complete with all lead | Cum | 2783.62 | 2783.62 | 18.0 | False | None | None | False | None | False | 50105.16 | 0 |
2322653 | 68617 | None | Item 339 | Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra) 600 x 300 x 150 mm Kerb Stone ---- etc., complete with all lead | m | 546.34 | 546.34 | 40.0 | False | None | None | False | None | False | 21853.6 | 0 |
2322654 | 68617 | None | Item 340 | Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces ---- etc., complete with all lead | Sqm | 128.62 | 128.62 | 28.0 | False | None | None | False | None | False | 3601.36 | 0 |
2322655 | 68617 | None | Item 341 | Providing and laying 60mm thick factory made precast M -30 grade Cement Concrete Paver Block as per IRC SP 63:2018 & IS 15658 for Cycle Tracks & Pedestrian Footpaths of approved shape and colour, laid in required pattern and including over 30mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-incharge. (WMM/WBM Base to be paid separately if necessary as per relevant technical specification) ---- etc., complete with all lead | Sqm | 1260.24 | 1260.24 | 80.0 | False | None | None | False | None | False | 100819.2 | 0 |
2322656 | 68617 | None | Item 342 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work Depth exceeding 1.5 m, but not exceeding 3 m ---- etc., complete with all lead | Cum | 501.5 | 501.5 | 16.575 | False | None | None | False | None | False | 8312.3625 | 0 |
2322657 | 68617 | None | Item 343 | Loading and Unloading of Stone Boulder/Stone aggregates/ Sand /Kankar/Moorum. (Disposal of 10Km) ---- etc., complete with all lead | Cum | 139.24 | 139.24 | 266.3 | False | None | None | False | None | False | 37079.612 | 0 |
2322658 | 68617 | None | Item 344 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. ---- etc., complete with all lead | Sqm | 112.1 | 112.1 | 262.53 | False | None | None | False | None | False | 29429.613 | 0 |
2322659 | 68617 | None | Item 345 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Foundation upto Plinth,b. All other types(3%) for Footing ---- etc., complete with all lead | Cum | 8012.15 | 8012.15 | 71.147 | False | None | None | False | None | False | 570040.43605 | 0 |
2322660 | 68617 | None | Item 346 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Foundation upto Plinth,b. All other types(3%) for Pedastal ---- etc., complete with all lead | Cum | 8160.53 | 8160.53 | 4.5225 | False | None | None | False | None | False | 36905.996925 | 0 |
2322661 | 68617 | None | Item 347 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Including Cost Of Centering & Shuttering) Page No 115 for Columns ---- etc., complete with all lead | Cum | 8882.21 | 8882.21 | 11.0628 | False | None | None | False | None | False | 98262.112788 | 0 |
2322662 | 68617 | None | Item 348 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Including Cost Of Centering & Shuttering) Page No 115 for Plint Beam, RCC BEAMS, RCC SLAB and LINTELS ---- etc., complete with all lead | Cum | 9689.69 | 9689.69 | 86.9548 | False | None | None | False | None | False | 842565.056012 | 0 |
2322663 | 68617 | None | Item 349 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Including Cost Of Centering & Shuttering) Page No 115 for RCC STAIRCASE ---- etc., complete with all lead | Cum | 11708.37 | 11708.37 | 3.3975 | False | None | None | False | None | False | 39779.187075 | 0 |
2322664 | 68617 | None | Item 350 | Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical Specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/Epoxy ---- etc., complete with all lead | Nos | 240.72 | 240.72 | 20.0 | False | None | None | False | None | False | 4814.4 | 0 |
2322665 | 68617 | None | Item 351 | KSRB 4-5 :Providing Lath plaster with cement mortar 1:3 5cm thick with 6mm dia mild steel bars at 20cms. C to c both horizontally and vertically fixing chicken mesh for drop chejjas, facia, backing to cup board including cost of all materials, labour, providing and removing form work HOM of machineries, curing, complete as per specification. ---- etc., complete with all lead | Sqm | 1460.84 | 1460.84 | 13.026 | False | None | None | False | None | False | 19028.90184 | 0 |
2322666 | 68617 | None | Item 352 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) ---- etc., complete with all lead | Cum | 7539.02 | 7539.02 | 1.539 | False | None | None | False | None | False | 11602.55178 | 0 |
2322667 | 68617 | None | Item 353 | KSRB 4-2.12 : Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. Specification No . KBS ---- etc., complete with all lead | Rmtr | 38.94 | 38.94 | 49.2 | False | None | None | False | None | False | 1915.848 | 0 |
2322668 | 68617 | None | Item 354 | Providing throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas & parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge. ---- etc., complete with all lead | Rmtr | 86.14 | 86.14 | 49.2 | False | None | None | False | None | False | 4238.088 | 0 |
2322669 | 68617 | None | Item 355 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- etc., complete with all lead | Nos | 7238.12 | 7238.12 | 10.0 | False | None | None | False | None | False | 72381.2 | 0 |
2322670 | 68617 | None | Item 356 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. ---- etc., complete with all lead | Nos | 1241.36 | 1241.36 | 10.0 | False | None | None | False | None | False | 12413.6 | 0 |
2322671 | 68617 | None | Item 357 | Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete. ---- etc., complete with all lead | Nos | 1168.2 | 1168.2 | 10.0 | False | None | None | False | None | False | 11682.0 | 0 |
2322672 | 68617 | None | Item 358 | Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete ---- etc., complete with all lead | Nos | 153.4 | 153.4 | 20.0 | False | None | None | False | None | False | 3068.0 | 0 |
2322673 | 68617 | None | Item 359 | Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms ---- etc., complete with all lead | Nos | 64.9 | 64.9 | 10.0 | False | None | None | False | None | False | 649.0 | 0 |
2322674 | 68617 | None | Item 360 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type) ---- etc., complete with all lead | Nos | 324.5 | 324.5 | 30.0 | False | None | None | False | None | False | 9735.0 | 0 |
2322675 | 68617 | None | Item 361 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm ---- etc., complete with all lead | Nos | 70.8 | 70.8 | 60.0 | False | None | None | False | None | False | 4248.0 | 0 |
2322676 | 68617 | None | Item 362 | Providing & Fixing of corner beads of wooden door frame to wall including cost of materials, labour charges, complete as per specifications. ---- etc., complete with all lead | Rmtr | 15.0 | 15.0 | 51.4 | False | None | None | False | None | False | 771.0 | 0 |
2322677 | 68617 | None | Item 363 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial ---- etc., complete with all lead | Sqm | 3919.96 | 3919.96 | 19.74 | False | None | None | False | None | False | 77380.0104 | 0 |
2322678 | 68617 | None | Item 364 | Providing & fixing fiber glass reinforced plastic (FRP) Door frame of cross section 90mm x 45mm having single rebate of 32mm x 15mm to recieve shutter of 30mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyster resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The fram,e shall be covered with fiber glass form all sides. MS stay shall be provided at the bottom to steady the frame. ---- etc., complete with all lead | m | 758.74 | 758.74 | 20.0 | False | None | None | False | None | False | 15174.8 | 0 |
2322679 | 68617 | None | Item 365 | Providing & fixing to existing door frames, 30mm thick Glass fibre reinforced plastic (FRP) panelled door shutter of required colour and approved brand and manufacture made with fire retardant grade unsaturated polyster resin, moulded to 3mm thick FRP Laminate for forming hollow railsand styles with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings cast monolithically with 5mm thick FRP Laminate for panels conforming to IS 14856 Including fixing to frames. 30 mm thickness ---- etc., complete with all lead | Sqm | 3780.72 | 3780.72 | 6.72 | False | None | None | False | None | False | 25406.4384 | 0 |
2322680 | 68617 | None | Item 366 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. ( Outside) ---- etc., complete with all lead | Sqm | 411.82 | 411.82 | 409.65 | False | None | None | False | None | False | 168702.063 | 0 |
2322681 | 68617 | None | Item 367 | Bore Packing : Filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulaion on the bore. Including all labour charges tools and equipments, all complete as per the manufacturer. ---- etc., complete with all lead | Sqm | 283.2 | 283.2 | 50.0 | False | None | None | False | None | False | 14160.0 | 0 |
2322682 | 68617 | None | Item 368 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead | Sqm | 348.1 | 348.1 | 67.473 | False | None | None | False | None | False | 23487.3513 | 0 |
2322683 | 68617 | None | Item 369 | Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis) ---- etc., complete with all lead | Sqm | 725.7 | 725.7 | 38.478 | False | None | None | False | None | False | 27923.4846 | 0 |
2322684 | 68617 | None | Item 370 | Fixing glazed/ Ceramic/ Vitrified floor tiles with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477, in average 3mm thickness. ---- etc., complete with all lead | Sqm | 416.54 | 416.54 | 91.17 | False | None | None | False | None | False | 37975.9518 | 0 |
2322685 | 68617 | None | Item 371 | Polishing on wood work with ready mixed wax polish of approved brand and manufacture : New work to give an even surface including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead | Sqm | 159.3 | 159.3 | 47.376 | False | None | None | False | None | False | 7546.9968 | 0 |
2322686 | 68617 | None | Item 372 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for COLUMNS ---- etc., complete with all lead | Cum | 8971.03 | 8971.03 | 1.323 | False | None | None | False | None | False | 11868.67269 | 0 |
2322687 | 68617 | None | Item 373 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for RCC BEAMS, RCC Slab and Lintels ---- etc., complete with all lead | Cum | 9786.59 | 9786.59 | 3.2293 | False | None | None | False | None | False | 31603.835087 | 0 |
2322688 | 68617 | None | Item 374 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all lead | Cum | 10743.66 | 10743.66 | 0.3579 | False | None | None | False | None | False | 3845.155914 | 0 |
2322689 | 68617 | None | Item 375 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all lead | Cum | 8150.37 | 8150.37 | 3.009 | False | None | None | False | None | False | 24524.46333 | 0 |
2322690 | 68617 | None | Item 376 | KSRB 4-2.12 : Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. Specification No . KBS ---- etc., complete with all lead | Rmtr | 39.33 | 39.33 | 5.5 | False | None | None | False | None | False | 216.315 | 0 |
2322691 | 68617 | None | Item 377 | Providing throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas & parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge. ---- etc., complete with all lead | Rmtr | 87.0 | 87.0 | 85.5 | False | None | None | False | None | False | 7438.5 | 0 |
2322692 | 68617 | None | Item 378 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all lead | Sqm | 8025.58 | 8025.58 | 1.8 | False | None | None | False | None | False | 14446.044 | 0 |
2322693 | 68617 | None | Item 379 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- etc., complete with all lead | Kg | 200.22 | 200.22 | 37.8 | False | None | None | False | None | False | 7568.316 | 0 |
2322694 | 68617 | None | Item 380 | KSRB-7.3: Providing and fixing 1mm thick M.S.steel garage door with frame and diagonal braces of size 40x40x6 mm angle Iron 3.15mm thick M.S.Gusset plates at the junctions and corners, with handles, stoppers and locking arrangements etc., including applying a priming coat of red lead paint cost of materials, labour, HOM of machinery complete as per specifications. ---- etc., complete with all lead | Sqm | 5336.88 | 5336.88 | 2.1 | False | None | None | False | None | False | 11207.448 | 0 |
2322695 | 68617 | None | Item 381 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. ( Outside) ---- etc., complete with all lead | Sqm | 415.94 | 415.94 | 858.961 | False | None | None | False | None | False | 357276.23834 | 0 |
2322696 | 68617 | None | Item 382 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead | Sqm | 59.59 | 59.59 | 3.9 | False | None | None | False | None | False | 232.401 | 0 |
2322697 | 68617 | None | Item 383 | PVC pipe - OD 110mm and 6 Kg/sqcm (Sl No 647 Page No A-44) ---- etc., complete with all lead | Rmtr | 303.91 | 303.91 | 90.0 | False | None | None | False | None | False | 27351.9 | 0 |
2322698 | 68617 | None | Item 384 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth 3 to 6m ---- etc., complete with all lead | Cum | 138.06 | 138.06 | 2.496 | False | None | None | False | None | False | 344.59776 | 0 |
2322699 | 68617 | None | Item 385 | Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in ---- etc., complete with all lead | Cum | 3019.62 | 3019.62 | 18.0 | False | None | None | False | None | False | 54353.16 | 0 |
2322700 | 68617 | None | Item 386 | Providing and fixing plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per Sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment ) Plaster mesh 100mm wide ---- etc., complete with all lead | Rmtr | 51.92 | 51.92 | 1084.5 | False | None | None | False | None | False | 56307.24 | 0 |