createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1706273399261
version4
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyRESERVED
invitingStrategyTextReserved
taxTypeINCLUSIVE_TAX
tenderFee1580.00
emd63000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose08-02-2024 16:01:57
tenderQueryClose07-02-2024 11:11:43
technicalBidOpen09-02-2024 16:08:08
publishedDate29-01-2024 11:37:39
publishedByPostPWD_EE_DIV_BID
publishedByUserKPE14569 - SHIVSHANKER V KAMSHETTY
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonShivshanker kamshetty
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08482226440
mobileNumberNone
tenderSupplierListNone
tenderSchedule
createdTs1706273399290
version4
createdDateNone
modifiedDateNone
tenderNumberPWD/2023-24/BD/WORK_INDENT7545
titleConstruction of community health center at Santhpur in Aurad (B) Taluka (Continued work)SC Reserved
descriptionConstruction of community health center at Santhpur in Aurad (B) Taluka (Continued work) SC Reserved
categoryWORKS
categoryTextWorks
ecv6291383.47
deptNamePublic Works Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location1692
locationNamePWD Division Office Bidar
provisionalAmount7500000.0
groupOverheadTotalNone
fileNumberpwd/sd/San/75/kkrdb/2022-23/n
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17062733990000NoneNoneBuildingsConstruction of community health center at Santhpur in Aurad (B) Taluka (Continued work)6291383.47
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
231443968195None2.1.6Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregates PWD SR-2023-24, Vol. 1Cum6555.156555.1521.05FalseNoneNoneFalseNoneFalse137985.90750
231444068195None11.3Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer including cost of materials ,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. PWD SR-2023-24,Vol. 2Sqm8689.88689.814.4FalseNoneNoneFalseNoneFalse125133.120
231444168195None11.3bProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. PWD SR-2023-24, Vol. 2Kg192.15192.15174.51FalseNoneNoneFalseNoneFalse33532.09650
231444268195None9.36Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab including cost of materials, labour, curing, polishing complete as per specifications PWD SR-2023-24, Vol. 2Sqm1732.51732.523.85FalseNoneNoneFalseNoneFalse41320.1250
231444368195None12.88Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. PWD SR-2023-24, Vol. 2Sqm5659.55659.518.57FalseNoneNoneFalseNoneFalse105096.9150
231444468195None12.92Providing& fixing of Openable door made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame PWD SR-2023-24, Vol. 2Sqm6557.256557.252.1FalseNoneNoneFalseNoneFalse13770.2250
231444568195None8.33.3Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. PWD SR-2023-24, Vol. 2Sqm145.95145.9523.67FalseNoneNoneFalseNoneFalse3454.63650
231444668195None1.4.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work In ordinary/soft rock without blasting up to 1.5 m depth PWD SR-2023-24, Vol. 1Cum254.1254.14.85FalseNoneNoneFalseNoneFalse1232.3850
231444768195None2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates PWD SR-2023-24, Vol. 1Cum6288.456288.450.81FalseNoneNoneFalseNoneFalse5093.64450
231444868195None5.1.1Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) PWD SR-2023-24, Vol. 2Cum5891.555891.552.73FalseNoneNoneFalseNoneFalse16083.93150
231444968195None5.4Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) PWD SR-2023-24, Vol. 2Cum6708.456708.452.31FalseNoneNoneFalseNoneFalse15496.51950
231445068195None1.11Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. PWD SR-2023-24, Vol. 1Cum454.65454.653.77FalseNoneNoneFalseNoneFalse1714.03050
231445168195None2.1.4Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates PWD SR-2023-24, Vol. 1Cum6527.856527.851.6FalseNoneNoneFalseNoneFalse10444.560
231445268195None6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. PWD SR-2023-24, Vol. 2Cum8367.458367.452.65FalseNoneNoneFalseNoneFalse22173.74250
231445368195None11.2Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications PWD SR-2023-24, Vol. 2Kg118.65118.65187.7FalseNoneNoneFalseNoneFalse22270.6050
231445468195None7.38Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches PWD SR-2023-24, Vol. 2Sqm596.4596.418.36FalseNoneNoneFalseNoneFalse10949.9040
231445568195None8.2.2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge PWD SR-2023-24, Vol. 2Sqm292.95292.9533.84FalseNoneNoneFalseNoneFalse9913.4280
231445668195None8.30Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. PWD SR-2023-24, Vol. 2Sqm182.7182.733.84FalseNoneNoneFalseNoneFalse6182.5680
231445768195None1.4.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth PWD SR-2023-24, Vol. 1Cum254.1254.128.01FalseNoneNoneFalseNoneFalse7117.3410
231445868195None2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates PWD SR-2023-24, Vol. 1Cum6288.456288.456.22FalseNoneNoneFalseNoneFalse39114.1590
231445968195None5.1.1Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) PWD SR-2023-24, Vol. 2Cum5891.555891.5518.95FalseNoneNoneFalseNoneFalse111644.87250
231446068195None5.4Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) PWD SR-2023-24, Vol. 2Cum6708.456708.4573.71FalseNoneNoneFalseNoneFalse494479.84950
231446168195None2.1.4Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates PWD SR-2023-24, Vol. 1Cum6527.856527.858.29FalseNoneNoneFalseNoneFalse54115.87650
231446268195None6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. PWD SR-2023-24, Vol. 2Cum8367.458367.4510.18FalseNoneNoneFalseNoneFalse85180.6410
231446368195None8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge PWD SR-2023-24, Vol. 2Sqm389.55389.55120.84FalseNoneNoneFalseNoneFalse47073.2220
231446468195None8.19.1Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge PWD SR-2023-24, Vol. 2Sqm267.75267.75243.0FalseNoneNoneFalseNoneFalse65063.250
231446568195None8.30Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. PWD SR-2023-24, Vol. 2Sqm182.7182.7425.4FalseNoneNoneFalseNoneFalse77720.580
231446668195None3.7Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction. PWD SR-2023-24, Vol. 3Cum110.25110.2523.16FalseNoneNoneFalseNoneFalse2553.390
231446768195None4.13, A (i) aProviding, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with 3 wheeled steel/ vibratory roller in stages to proper grade and camber, applying and brooming requisite type of screening/binding Materials to fill up the interstices of coarse aggregate, watering and compacting to the required density PWD SR-2023-24 Vol. 3Cum2649.152649.1511.58FalseNoneNoneFalseNoneFalse30677.1570
231446868195None16.27Providing and constructing un-reinforced plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M20 (Grade), coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 m3 capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), complete. as per the directions of the Engineer-in-charge of the work. PWD SR-2023-24, Vol. 3Cum6692.76692.750.0FalseNoneNoneFalseNoneFalse334635.00
231446968195None1.1.3Open couduit Supplying heavy gauge PVC conduit pipe ……mm dia .mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 32mm dia 25mm thick Electrical SR 2023-24Rmtr106.0106.0600.0FalseNoneNoneFalseNoneFalse63600.00
231447068195None1.2.3Concealed couduit Supplying heavy gauge PVC conduit pipe ……mm dia .mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 32mm dia 25mm thick Electrical SR 2023-24Rmtr103.0103.0550.0FalseNoneNoneFalseNoneFalse56650.00
231447168195None1.5.3Supplying and fixing PVC/metal conduit Deep junction box No61.061.0200.0FalseNoneNoneFalseNoneFalse12200.00
231447268195None2.1.4Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) Two outlet in a row Electrical SR 2023-24No708.0708.0590.0FalseNoneNoneFalseNoneFalse417720.00
231447368195None3.14.5Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board 6A Bakelite Ceiling Rose Electrical SR 2023-24No78.078.0321.0FalseNoneNoneFalseNoneFalse25038.00
231447468195None3.14.3Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board 6A Three Way 5 Pin Socket Electrical SR 2023-24No70.070.0310.0FalseNoneNoneFalseNoneFalse21700.00
231447568195None3.14.6Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board 6A Lamp holders PWD Electrical SR 2023-24No71.071.0160.0FalseNoneNoneFalseNoneFalse11360.00
231447668195None12.14.2Supplying and fixing of slim box fitting made out of CRCA Sheet metal body with locking type holder completely wired. Excluding Ballast & Fluorescent Tube. 1 x 4' Tube light fitting.No361.0361.0150.0FalseNoneNoneFalseNoneFalse54150.00
231447768195None5.17.3Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC61439-3 and IK09 tested as per IS/IEC62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, onwall/woodboard/flushmountingusingrequiredclA,bolts,nuts,etc.,withprovisionforfixingofsuitabletypecapacityMCCB'sasanincomerfor3phaseDoubledoorwithnecessarybusbarcompletelywired PWD Electrical SR 2023-24No15529.015529.011.0FalseNoneNoneFalseNoneFalse170819.00
231447868195None2.1.5Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) 3 outlet in a row PWD Electrical SR 2023-24No1035.01035.0350.0FalseNoneNoneFalseNoneFalse362250.00
231447968195None2.5.4Supplying and drawing Flexible Multi core Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 6C x 1.5 mm2No121.0121.0450.0FalseNoneNoneFalseNoneFalse54450.00
231448068195None2.5.5Supplying and drawing Flexible Multi core Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 8C x 1.5 mm2 PWD Electrical SR 2023-24No158.0158.0650.0FalseNoneNoneFalseNoneFalse102700.00
231448168195None3.1.1Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 6 Amps 2 wayNo128.0128.0750.0FalseNoneNoneFalseNoneFalse96000.00
231448268195None3.6.2Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A Two Way SwitchNo166.0166.01550.0FalseNoneNoneFalseNoneFalse257300.00
231448368195None3.3.2Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 4-5 wayNo137.0137.0850.0FalseNoneNoneFalseNoneFalse116450.00
231448468195None2.5.2Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS-694:2010 4C x 6 mm2No328.0328.0350.0FalseNoneNoneFalseNoneFalse114800.00
231448568195None3.3.4Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 6 wayNo173.0173.0120.0FalseNoneNoneFalseNoneFalse20760.00
231448668195None3.6.5Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 400W dimmerNo276.0276.070.0FalseNoneNoneFalseNoneFalse19320.00
231448768195None3.6.9Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32A DP SwitchNo326.0326.060.0FalseNoneNoneFalseNoneFalse19560.00
231448868195None5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32Amps SPNo415.0415.080.0FalseNoneNoneFalseNoneFalse33200.00
231448968195None5.20.1Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker (ELMCB) 240/450V upto 300mA sensitivity on existing wood/panel board. 16-25 A 2 poleNo4277.04277.04.0FalseNoneNoneFalseNoneFalse17108.00
231449068195None5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A DPNo739.0739.035.0FalseNoneNoneFalseNoneFalse25865.00
231449168195None5.42.1Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clampsSq CM0.50.565000.0FalseNoneNoneFalseNoneFalse32500.00
231449268195None6.1Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz AC Supply completeNo1492.01492.018.0FalseNoneNoneFalseNoneFalse26856.00
231449368195None6.3.1Supplying capacitor type ceiling fan complete with down rod blades, snackles, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply confirming to IS-374-1979 and with double ball bearing system. 48" sweep (1200mm) regular modelNo2984.02984.040.0FalseNoneNoneFalseNoneFalse119360.00
231449468195None6.7.2Supplying .TR split Air conditioners suitable for operation on A/C supply single phase 50 Hz 230 V with hermetically sealed compressor with air cooled condenser, motor capacitor and start run capacitors, relay and over load protector internal unit, with one indoor and one outdoor unit 1.5 Ton capacityNo56355.056355.010.0FalseNoneNoneFalseNoneFalse563550.00
231449568195None9.2.5Supplying, erecting, testing & commissioning of OFF- LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with all accessories complete and Excluding batteries and wiring complete. 5 KVA ON LINE UPSNo39898.039898.02.0FalseNoneNoneFalseNoneFalse79796.00
231449668195None9.5.9Supplying, installation, testing & commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries. 150Ah CapacityNo15895.015895.012.0FalseNoneNoneFalseNoneFalse190740.00
231449768195None11.3.2Supplying & fixing - flexible LED Strip Light . W Power consumption in 5 ms length 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic BIS Approved with 2 years Warranty against any manufacturing defect working under standard electrical conditionNo690.0690.060.0FalseNoneNoneFalseNoneFalse41400.00
231449868195None11.1Supplying & fixing - flexible LED Strip Light . W Power consumption in The LED are driven by HF electronic BIS Approved with 2 years Warranty against any manufacturing defect working under standard electricalcondition.No1291.01291.060.0FalseNoneNoneFalseNoneFalse77460.00
231449968195None10.1.7Supplying, installing, testing and commissioning of Diesel Generator set with following specifications. Power rating as per standard reference condition as per-BS 5514/ISO 3046/ ISO 8528 & IS 1002/ISO 3046 Generator set specifications. 62.5 kVA/50kWSet641071.0641071.01.0FalseNoneNoneFalseNoneFalse641071.00
231450068195None3.5.2Supply, Erection, testing and commissioning of AMF panel suitable for .kVA DG set. The panel is of cubical type base/floor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the accommodation for .A 4 pole contactor for alternator with thermal O/L relay,. A 4 pole contactor for mains, 62.5KVA to 125 KVANo77768.077768.01.0FalseNoneNoneFalseNoneFalse77768.00
231450168195None12.60.1Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut-outs& otherequipments backfill compound which is non- corrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, nontoxic, weather resistance & capable of achieving ohmic value less than one ohmNo4258.04258.010.0FalseNoneNoneFalseNoneFalse42580.00
231450268195None12.58.2GI/Copper strips for grounding connections, using necessary fixing materials as required 25 x 3 mm GI stripRmtr128.0128.0110.0FalseNoneNoneFalseNoneFalse14080.00
231450368195None12.58.7GI/Copper strips for grounding connections, using necessary fixing materials as required 25 x 3 mm Copper stripRmtr570.0570.0110.0FalseNoneNoneFalseNoneFalse62700.00
231450468195NoneMR1Providing and fixing of copper lengthening arrestor as per market rateNo4900.04900.04.0FalseNoneNoneFalseNoneFalse19600.00
231450568195None15.7.3Supply, erection, testing and commissioning of . KVA 4Star rated Aluminium/Copper wound Distribution Transformer 11KV/433V with Off Load Tap Switch, Buchholtz relay winding temperature indicator, oil temperature indicator, marshalling box with wiring, oil level indicator 100 KVA PWD Electrical SR 2019-20No205003.0205003.01.0FalseNoneNoneFalseNoneFalse205003.00
231450668195NoneMR2Transformer allied works as per Market ratesNo45000.045000.01.0FalseNoneNoneFalseNoneFalse45000.00
231450768195None33.10Supply, erection, testing and commissioning of . KVA 4Star rated Aluminium/Copper wound Distribution Transformer 11KV/433V with Off Load Tap Switch, Buchholtz relay winding temperature indicator, oil temperature indicator, marshalling box with wiring, oil level indicator with + 5% to -10% Steps of 2.5%, HT and LT Cable Entry Box Type, BESCOM Electrical SR 21-22, P. No. 9Km238479.0238479.00.2FalseNoneNoneFalseNoneFalse47695.80
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17062734000000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17062734000000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17062734000000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17062734250000NoneNoneELIGIBILITYG.S.T. at the prevailing rates will be given separately.None
17062734410000NoneNoneELIGIBILITYThe Tenderer shall furnish, as part of his tender, earnest money deposit in the amount as shown in column 4 of the Table of IFT for this particular work. Tenderer can pay the full EMD amount of Rs. 1,25,827/- through e-payment or the Earnest Money Deposit shall be in two parts. Part(1): Rs. 50,000/- by e-payment, Part-(2): Rs. 75,827/- EMD shall be in favour of Executive Engineer, PWD, Bidar Division, Bidar, and may be in the form of Bankers Cheque/Demand Draft/Pay order in favour of Executive Engineer, PWD, Bidar Division, Bidar, payable at Bidar or cash or specified Small Savings Instruments pledged to the Executive Engineer, PWD, Bidar DivisionNone
17062734510000NoneNoneELIGIBILITYPeriod for completion of this work is 06(Six) months including Monsoon.None
17062734620000NoneNoneELIGIBILITYThis work is reserved for Scheduled Caste (SC) Contractor only Registered Scheduled Cast Certificate can submit their tender and should upload the Caste Certificate issued by the Competent Authority.None
17062734940000NoneNoneELIGIBILITYTo qualify for award of this contract, each Tenderer in its name should have in the last five years i.e., 2018-19 ,2019-20 ,2020-21 2021-22 and 2022-23 (a) achieved in at least One financial years a minimum financial turn over (in all cases of civil engineering construction works only) Rs. 62.92 Lakhs/- Turnover certificate must have UDI number , otherwise it will not be considered for further bid evaluation.None
17062735580000NoneNoneELIGIBILITYLiquid Assets and/or availability of credit facilities of not less than Rs. 18.88 Lakhs Lakhs (Credit Lines/Letter of Credit/Certificates from the Banks for meeting the fund requirement etc.None
17062735870000NoneNoneELIGIBILITYTo qualify for award of this contract, each Tenderer in its name should have in the last five years i.e., 2018-19 ,2019-20 ,2020-21 2021-22 and 2022-23 (b) satisfactorily completed as prime contractor, at least one similar work such as Any Construction of Work such as of value not less than Rs 15.73 Lakhs/-None
17062736030000NoneNoneELIGIBILITYTo qualify for award of this contract, each Tenderer in its name should have in the last five years i.e., 2018-19 ,2019-20 ,2020-21 2021-22 and 2022-23 (c) executed in any one year, the following minimum quantities of work(1)Earth work excavation/embankment/shoulders: 48.00 cum (2)BBM/SSM: 86.2 Cum (3) Plastering: 123.75 Sqm (4) PCC/RCC : 70.00 Cum (6) Flooring:19.08 SqmNone
17062736130000NoneNoneELIGIBILITYThe tenderer or his identified sub-contractor should posses required valid electrical licence for executing Building Electrification woks, and should have executed similar works, totaling Rs. 43.60 LakhsNone
17063401150000NoneNoneELIGIBILITYThe Tenderer shall furnish, as part of his tender, earnest money deposit in the amount as shown in column 4 of the Table of IFT for this particular work. Tenderer can pay the full EMD amount of Rs. 63,000/- through e-paymentNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneTo qualify for award of this contract, each Tenderer in its name should have in the last five years i.e., 2018-19 ,2019-20 ,2020-21 2021-22 and 2022-23 (b) satisfactorily completed as prime contractor, at least one similar work such as Any Construction of Work such as of value not less than Rs 15.73 Lakhs/-Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneThe tenderer or his identified sub-contractor should posses required valid electrical licence for executing Building Electrification woks, and should have executed similar works, totaling Rs. 43.60 LakhsPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneList of Existing WorksPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- List of Existing Works
NoneNoneNoneNoneList of tenders already submittedPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- List of tenders already submitted
NoneNoneNoneNoneTo qualify for award of this contract, each Tenderer in its name should have in the last five years i.e., 2018-19 ,2019-20 ,2020-21 2021-22 and 2022-23 (a) achieved in at least One financial years a minimum financial turn over (in all cases of civil engineering construction works only) Rs. 62.92 Lakhs/- Turnover certificate must have UDI number , otherwise it will not be considered for further bid evaluation.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneLiquid Assets and/or availability of credit facilities of not less than Rs. 18.88 Lakhs Lakhs (Credit Lines/Letter of Credit/Certificates from the Banks for meeting the fund requirement etc.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneTo qualify for award of this contract, each Tenderer in its name should have in the last five years i.e., 2018-19 ,2019-20 ,2020-21 2021-22 and 2022-23 (a) achieved in at least One financial years a minimum financial turn over (in all cases of civil engineering construction works only) Rs. 62.92 Lakhs/- Turnover certificate must have UDI number , otherwise it will not be considered for further bid evaluation.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneReport on the financial standing of the Tenderer, such as profit and loss statements and auditors report for last five years.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Profit and loss statements
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
Company Registration CertificateTrueTechnical Bid
Reserved Category Certificate Scheduled CasteTrueTechnical Bid
Work done CertificateTrueTechnical Bid
Line of CreditTrueTechnical Bid
Other DocumentsFalseTechnical Bid
tenderWorkLocationList
tenderSubEstimateNamedistrictNametaluqNameloksabhaContNameassemblyContNamelocationDescriptionlatitudeDegreeslatitudeMinuteslatitudeSecondslongitudeDegreeslongitudeMinuteslongitudeSeconds
BuildingsBidarAuradBidarAURADHospital buildingNoneNoneNoneNoneNoneNone
tenderAddressNone
tenderRecallDTONone