| 1703141062000 | 0 | None | None | Water supply/sewage lines | Providing pipeline at ward no 6 and ward no 15 And Drilling of borewell cistern tank fixing of motor at ward no 04 and construction of cistern tank at ward no 12 | 328410.64 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 1889516 | 54283 | None | code01 | Cutting Cement Concrete Road surface by Machine cutting to demarcate the trench width of the surface. | Cum | 979.53 | 979.53 | 7.65 | False | None | None | False | None | False | 7493.4045 | 0 | | 1889517 | 54283 | None | code02 | Earth work excavation for pipeline trenches in all kinds of soils by mechanical means above 600 mm (Depth upto 1.50m not exceeding 1.5m in width ) trench width as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & boning rods at every 100 mm whevere necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata. | Cum | 199.82 | 199.82 | 17.21 | False | None | None | False | None | False | 3438.9022 | 0 | | 1889518 | 54283 | None | code03 | Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete. | Mtr | 157.59 | 157.59 | 85.0 | False | None | None | False | None | False | 13395.15 | 0 | | 1889519 | 54283 | None | code04 | Supplying and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of ductile iron (DI) conforming to IS-1865 and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100% leak proof with face to face dimensions as per IS 14846-2000 only. The stem sealing should be with toroidal sealing rings (minimum 2 “ O “ rings). Body and bonut should be coated with Electrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves, T.P set, galvanized bolts & nuts and rubber insertions etc. but excluding earth work. | Each | 8253.39 | 8253.39 | 2.0 | False | None | None | False | None | False | 16506.78 | 0 | | 1889520 | 54283 | None | code05 | Supply and delivery at site special moulded variety PVC bend as per IS7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments | Each | 95.79 | 95.79 | 3.0 | False | None | None | False | None | False | 287.37 | 0 | | 1889521 | 54283 | None | code06 | Supply and delivery at site special moulded variety PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments | Each | 269.86 | 269.86 | 1.0 | False | None | None | False | None | False | 269.86 | 0 | | 1889522 | 54283 | None | code07 | Supply and delivery at site special moulded variety PVC service saddles as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments | Each | 415.09 | 415.09 | 1.0 | False | None | None | False | None | False | 415.09 | 0 | | 1889523 | 54283 | None | code08 | Fixing sluice valves/ Butterfly Valves (labour charges only) conforming to relevant ISS with latest amendments as detailed below for the followingdiameter and types with two Nos of MJ collars, two flanged spigots, conveying to work site, loading, unloading, stacking with appurtenances. with all lead and lifts, aligning, fixing and testing with appurtenances. complete. | Each | 323.42 | 323.42 | 1.0 | False | None | None | False | None | False | 323.42 | 0 | | 1889524 | 54283 | None | code09 | Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications | Cum | 125.66 | 125.66 | 17.21 | False | None | None | False | None | False | 2162.6086 | 0 | | 1889525 | 54283 | None | code10 | PQC : Providing and constructing un-reinforced plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M20 (Grade), coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including construction joints, , primer, sealant , curing of concrete slabs for 14- days, and water finishing to lines and grade as per drawing and technical specification clause 1501 with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments etc., complete. as per the directions of the Engineer-in-charge of the work | Cum | 6177.94 | 6177.94 | 5.74 | False | None | None | False | None | False | 35461.3756 | 0 | | 1889526 | 54283 | None | code11 | Sinking of Borewell of 165mm dia clear using super fast hydraulic Rig of capacity 250 PSIG &above 900 CFM & above in all strata including over burden upto 20mtrs. Fixing of casing pipes, collars &cap with necessary cutting,threading & welding including transportation of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour(excluding cost of casing pipes collars and cap etc.) (BWSSB SR 2021-22 P No. 151 It No 1.1, 1.2, 1.3) | Mtr | 298.7 | 298.7 | 50.0 | False | None | None | False | None | False | 14935.0 | 0 | | 1889527 | 54283 | None | code12 | Sinking of Borewell of 165mm dia clear using super fast hydraulic Rig of capacity 250 PSIG &above 900 CFM & above in all strata including over burden upto 20mtrs. Fixing of casing pipes, collars &cap with necessary cutting,threading & welding including transportation of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour(excluding cost of casing pipes collars and cap etc.) (BWSSB SR 2021-22 P No. 151 It No 1.1, 1.2, 1.3) | Mtr | 374.92 | 374.92 | 50.0 | False | None | None | False | None | False | 18746.0 | 0 | | 1889528 | 54283 | None | code13 | Sinking of Borewell of 165mm dia clear using super fast hydraulic Rig of capacity 250 PSIG &above 900 CFM & above in all strata including over burden upto 20mtrs. Fixing of casing pipes, collars &cap with necessary cutting,threading & welding including transportation of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour(excluding cost of casing pipes collars and cap etc.) (BWSSB SR 2021-22 P No. 151 It No 1.1, 1.2, 1.3) | Mtr | 398.61 | 398.61 | 45.0 | False | None | None | False | None | False | 17937.45 | 0 | | 1889529 | 54283 | None | code14 | Providing 160 mm casing pipe with M.S. coller (BWSSB SR 2021-22 P No. 154 It No 32) | Nos | 1990.99 | 1990.99 | 1.0 | False | None | None | False | None | False | 1990.99 | 0 | | 1889530 | 54283 | None | code15 | Providing 200mm PVC casing cap including fixing charges (BWSSB SR 2021-22 P No. 155 It No 34) | Nos | 168.92 | 168.92 | 1.0 | False | None | None | False | None | False | 168.92 | 0 | | 1889531 | 54283 | None | code16 | Geophysical Investigation of site for sinking Borewell Geophysical Investigation of site for sinking Borewell for supplying drinking water to the habitation either through a hand pump, Mini Water Supply scheme, or Piped Water Supply Scheme by vertical electrical sounding by adopting venner or Schlumberger's method, including reconnaissance survey of geological formation, geophysical investigation of existing ground water in the vicinity, its quality, quantity & acceptability of the users indicating the location of site, recommended depth of casing pipe required to seal the top unconsolidated formation incluing an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instrument and accessories to work site, engaging technical personal and labour required etc., complete.(BWSSB SR 2021-22 P No. 151 It No 4) | Nos | 5295.23 | 5295.23 | 1.0 | False | None | None | False | None | False | 5295.23 | 0 | | 1889532 | 54283 | None | code17 | Providing, supplying to work site,Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications,with testing of as per instructions of engineer incharge of work and latest amendments.5.00 HP/1.5KW 12 STG .(BWSSB SR 2021-22 P No. 159 It No 10.1) (H.P - 5 / 3.7KW Stage 25 Head 100.00 Mtr) | Set | 27835.75 | 27835.75 | 1.0 | False | None | None | False | None | False | 27835.75 | 0 | | 1889533 | 54283 | None | code18 | Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter Upto 6 HP pumps (BWSSB SR 2021-22 P No. 162 It No 29.1) | Set | 9785.0 | 9785.0 | 1.0 | False | None | None | False | None | False | 9785.0 | 0 | | 1889534 | 54283 | None | code19 | Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. Note: Upto 110mm dia Coil shall be used. For Grade PE80 PN6.0 : HDPE Grade PE80-PN6.0, 63mm dia m 63 mm dia.(BWSSB SR 2021-22 P No. 121 It No 1.1) | Mtr | 147.29 | 147.29 | 130.0 | False | None | None | False | None | False | 19147.7 | 0 | | 1889535 | 54283 | None | code20 | SubmersibleCable: Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments. 1x3x4 Sqm.(BWSSB SR 2021-22 P No. 161 It No 22.3) | Mtr | 169.95 | 169.95 | 130.0 | False | None | None | False | None | False | 22093.5 | 0 | | 1889536 | 54283 | None | code21 | Pressure Guage: Supply and Delevery of brand new best make pressure guage (Bourdon Type size confirming to IS 3624/87 with latest amendments with ISI mark as provided in SPD rate contract. .(BWSSB SR 2021-22 P No. 162 It No 26.1) | Nos | 463.5 | 463.5 | 2.0 | False | None | None | False | None | False | 927.0 | 0 | | 1889537 | 54283 | None | code22 | Supply and delivery best indegeneous brand new power capacitor as per IS 283/86 with latest amendments with ISI mark of required capacity tested and approved by one KEB aouthorities and erection. Electrification and commissioning of the same at the location of the respective pumpsets as provided in SPD rate contract . (BWSSB SR 2021-22 P No. 162 It No 31) | Kvar | 566.5 | 566.5 | 1.0 | False | None | None | False | None | False | 566.5 | 0 | | 1889538 | 54283 | None | code23 | Supply and delivery at site delivery of best indigenous brand new MCB (Miniature Circuit Breakers) of required capacity as per IS 88228/1978 and its latest amendments and with ISI Mark of 6/10/16/20/25/40 Amps with scalable box.(BWSSB SR 2021-22 P No. 162 It No 32) Per 3 polse | Nos | 1287.5 | 1287.5 | 1.0 | False | None | None | False | None | False | 1287.5 | 0 | | 1889539 | 54283 | None | code24 | Labour charges for erection of indoor type panel board and meter board units with all necessary materials and labour tools and equipments including cement concrete for foundation/bed etc,complete as per specification, with testing of as per instructions of engineer incharge of work.(BWSSB SR 2021-22 P No. 163 It No 39) | Job | 1287.5 | 1287.5 | 1.0 | False | None | None | False | None | False | 1287.5 | 0 | | 1889540 | 54283 | None | code25 | Providing main connection from pole PVC insulated sheathed steel wire cable in new trench as per IS 1554/ 1988 with latest amendments with ISI mark from KPTCL pole to meter board unit..(BWSSB SR 2021-22 P No. 163 It No 42) | Mtr | 139.05 | 139.05 | 50.0 | False | None | None | False | None | False | 6952.5 | 0 | | 1889541 | 54283 | None | code26 | Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia. (BWSSB SR 2021-22 P No. 164 It No 45) | Job | 3862.5 | 3862.5 | 1.0 | False | None | None | False | None | False | 3862.5 | 0 | | 1889542 | 54283 | None | code27 | Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments 65 mm dia non return valve (BWSSB SR 2021-22 P No. 162 It No 28.2) | Each | 1534.7 | 1534.7 | 1.0 | False | None | None | False | None | False | 1534.7 | 0 | | 1889543 | 54283 | None | code28 | Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. (BWSSB SR 2021-22 P No. 162 It No 28.2) | Job | 6334.5 | 6334.5 | 2.0 | False | None | None | False | None | False | 12669.0 | 0 | | 1889544 | 54283 | None | code29 | Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work.In ordinary/soft rock without blasting upto 1.5 m depth (PWD SR 2021-22 Vol- 1 P no -6 Item No : 1.5.1) | Cum | 235.87 | 235.87 | 3.47 | False | None | None | False | None | False | 818.4689 | 0 | | 1889545 | 54283 | None | code30 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates (PWD SR 2021-22 Vol- 1 P no -15 Item No : 2.1.3) | Cum | 5720.62 | 5720.62 | 0.58 | False | None | None | False | None | False | 3317.9596 | 0 | | 1889546 | 54283 | None | code31 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement: 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1 cement : 6 coarse sand) PWD SR 2021-22 Vol- 2 P no -09 Item No : 5.1.1 | Cum | 4892.5 | 4892.5 | 6.75 | False | None | None | False | None | False | 33024.375 | 0 | | 1889547 | 54283 | None | code32 | RCC hume pipe Circular pump house: Supplying precast RCC Circular Hume pipe pump house with M.S door and RCC conical roof as per specification and drawings - Internal dia Mtr. 1200 mm & height of 2.5 Mtr. With Wall thickness 65mm PWD SR 2021-22 Vol- 5 P no -136 Item No : 5.2 M 070A | Each | 16893.03 | 16893.03 | 2.0 | False | None | None | False | None | False | 33786.06 | 0 | | 1889548 | 54283 | None | code33 | Erection and positioning of RCC Hume pipe pump house/Cistern on size stone masory platform including transportation charges and handling,finishing with all necessary tools ,plants and materials etc.,complete as directed by the Engineer in charge of the work. (PWD SR 2021-22 Vol- 5 P no -136 Item No : 5.3 M 080A) | Each | 1938.46 | 1938.46 | 2.0 | False | None | None | False | None | False | 3876.92 | 0 | | 1889549 | 54283 | None | code34 | Medium Duty GI pipe of 32mm dia (PWD SR 2021-22 Vol- 5 P no -142 Item No : 2.4 N 010D) | Rmtr | 322.39 | 322.39 | 12.0 | False | None | None | False | None | False | 3868.68 | 0 | | 1889550 | 54283 | None | code35 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (PWD SR 2021-22 Vol- 2 P no -41 Item No : 8.1.2) | Sqm | 203.94 | 203.94 | 9.8296 | False | None | None | False | None | False | 2004.648624 | 0 | | 1889551 | 54283 | None | code36 | Finishing walls with water proofing cement paint of required shade : Old work (one coats @ 2.20 kg/10 m²) complete. including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR 2021-22 Vol- 2 P no -53 Item No : 8.72.2) | Sqm | 43.26 | 43.26 | 21.6556 | False | None | None | False | None | False | 936.821256 | 0 |
|