| 2328913 | 68825 | None | code01 | Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m Vol- 1 (KPWD SR 2023-24/P.No.5/1.4.1) | Cum | 249.26 | 249.26 | 176.7735 | False | None | None | False | None | False | 44062.56261 | 0 |
| 2328914 | 68825 | None | code02 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. Vol- 2 (KPWD SR 2023-24/P.No.5/4.1) | Sqm | 121.54 | 121.54 | 103.04 | False | None | None | False | None | False | 12523.4816 | 0 |
| 2328915 | 68825 | None | code03 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates Vol- 1 (KPWD SR 2023-24/P.No.15/2.1.3) | Cum | 6168.67 | 6168.67 | 26.1171 | False | None | None | False | None | False | 161107.771257 | 0 |
| 2328916 | 68825 | None | code04 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) Vol- 2 (KPWD SR 2023-24/P.No.9/5.4) | Cum | 6580.67 | 6580.67 | 88.476 | False | None | None | False | None | False | 582231.35892 | 0 |
| 2328917 | 68825 | None | code05 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates Vol- 1 (KPWD SR 2023-24/P.No.15/2.1.3) | Cum | 9869.87 | 9869.87 | 7.1892 | False | None | None | False | None | False | 70956.469404 | 0 |
| 2328918 | 68825 | None | code06 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances
required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Vol- 1 (KPWD SR 2023-24/P.No.15/2.2.1) | Cum | 9713.41 | 9713.41 | 2.5395 | False | None | None | False | None | False | 24667.204695 | 0 |
| 2328919 | 68825 | None | code07 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances
required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Vol- 1 (KPWD SR 2023-24/P.No.15/2.2.1) | Cum | 10360.97 | 10360.97 | 4.8744 | False | None | None | False | None | False | 50503.512168 | 0 |
| 2328920 | 68825 | None | code08 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances
required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Vol- 1 (KPWD SR 2023-24/P.No.15/2.2.1) | Cum | 9713.41 | 9713.41 | 16.62 | False | None | None | False | None | False | 161436.8742 | 0 |
| 2328921 | 68825 | None | code09 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances
required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Vol- 1 (KPWD SR 2023-24/P.No.15/2.2.1) | Cum | 10360.97 | 10360.97 | 2.5875 | False | None | None | False | None | False | 26809.009875 | 0 |
| 2328922 | 68825 | None | code10 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates Vol- 1 (KPWD SR 2023-24/P.No.15/2.1.2) | Cum | 9334.27 | 9334.27 | 1.5525 | False | None | None | False | None | False | 14491.454175 | 0 |
| 2328923 | 68825 | None | code11 | Steel Fabrication - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a.Buildings Vol- 1 (KPWD SR 2023-24/P.No.18/2.11-a) | Tonne | 92140.71 | 92140.71 | 3.0006 | False | None | None | False | None | False | 276477.414426 | 0 |
| 2328924 | 68825 | None | code12 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m
and lift upto 1.5 m. Vol- 1 (KPWD SR 2023-24/P.No.7/1.9) | Cum | 273.98 | 273.98 | 62.1801 | False | None | None | False | None | False | 17036.103798 | 0 |
| 2328925 | 68825 | None | code13 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and
compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials, usage& all other appurtenaces required to complete the work.Vol- 1 (KPWD SR 2023-24/P.No.7/1.8) | Cum | 488.22 | 488.22 | 106.8466 | False | None | None | False | None | False | 52164.647052 | 0 |
| 2328926 | 68825 | None | code14 | Loading and Unloading of Stone Boulder/Stone aggregates/Sand/ Kankar/Moorum. (Tipper 18 m3) Vol- 3 (KPWD SR 2023-24/P.No.5/1.1-d) | Cum | 89.61 | 89.61 | 114.5934 | False | None | None | False | None | False | 10268.714574 | 0 |
| 2328927 | 68825 | None | code15 | Cost of Haulage Excluding Loading and Unloading Case-II : Unsurfaced Gravelled Road Taking output 10 t load and lead 10 km = 100 t.km Vol- 3 (KPWD SR 2023-24/P.No.5/1.4-(ii)) (Rs. 14 for 10km, for 30km considered Rs. 42) | T.Km | 43.26 | 43.26 | 183.3494 | False | None | None | False | None | False | 7931.695044 | 0 |
| 2328928 | 68825 | None | code16 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage
charges of machinery etc complete as per specifications. Vol- 2 (KPWD SR 2023-24/P.No.17/6.32) | Sqm | 1349.3 | 1349.3 | 159.84 | False | None | None | False | None | False | 215672.112 | 0 |
| 2328929 | 68825 | None | code17 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in foundations and plinth in Cement mortar 1:3 (1 cement : 3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. Vol- 2 (KPWD SR 2023-24/P.No.14/6.12) | Sqm | 1033.09 | 1033.09 | 111.2999 | False | None | None | False | None | False | 114982.813691 | 0 |
| 2328930 | 68825 | None | code18 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment - Plaster mesh 150mm wide Vol- 2 (KPWD SR 2023-24/P.No.43/8.16.2) | m | 39.14 | 39.14 | 136.0 | False | None | None | False | None | False | 5323.04 | 0 |
| 2328931 | 68825 | None | code19 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Vol- 2 (KPWD SR 2023-24/P.No.42/8.8) | Sqm | 382.13 | 382.13 | 267.4688 | False | None | None | False | None | False | 102207.852544 | 0 |
| 2328932 | 68825 | None | code20 | Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineerin- Charge. Vol- 2 (KPWD SR 2023-24/P.No.43/8.12) | Kg | 65.92 | 65.92 | 40.1203 | False | None | None | False | None | False | 2644.730176 | 0 |
| 2328933 | 68825 | None | code21 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Vol- 2 (KPWD SR 2023-24/P.No.43/8.10) | Sqm | 232.1 | 232.1 | 102.4407 | False | None | None | False | None | False | 23776.48647 | 0 |
| 2328934 | 68825 | None | code22 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Vol- 2 (KPWD SR 2023-24/P.No.41/8.1.2) | Sqm | 248.23 | 248.23 | 178.475 | False | None | None | False | None | False | 44302.84925 | 0 |
| 2328935 | 68825 | None | code23 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Vol- 2 (KPWD SR 2023-24/P.No.41/8.2.1) | Sqm | 303.85 | 303.85 | 159.575 | False | None | None | False | None | False | 48486.86375 | 0 |
| 2328936 | 68825 | None | code24 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Vol- 2 (KPWD SR 2023-24/P.No.50/8.51) | Sqm | 103.0 | 103.0 | 280.9157 | False | None | None | False | None | False | 28934.3171 | 0 |
| 2328937 | 68825 | None | code25 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 g/L as per specifications and as per directions of Engineer in charge. Vol- 2 (KPWD SR 2023-24/P.No.51/8.55.2) | Sqm | 54.59 | 54.59 | 280.9157 | False | None | None | False | None | False | 15335.188063 | 0 |
| 2328938 | 68825 | None | code26 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Vol- 2 (KPWD SR 2023-24/P.No.46/8.30) | Sqm | 179.22 | 179.22 | 267.4688 | False | None | None | False | None | False | 47935.758336 | 0 |
| 2328939 | 68825 | None | code27 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per
directions of Engineer-in-charge Vol- 2 (KPWD SR 2023-24/P.No.48/8.39) | Sqm | 130.81 | 130.81 | 280.9157 | False | None | None | False | None | False | 36746.582717 | 0 |
| 2328940 | 68825 | None | code28 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. Vol- 2 (KPWD SR 2023-24/P.No.64/9.30) | Sqm | 5487.84 | 5487.84 | 25.398 | False | None | None | False | None | False | 139380.16032 | 0 |
| 2328941 | 68825 | None | code29 | Providing half nosing for 20mm thick granite slab using required machinery including cost and conveyance of all materials, labour for all items of work, HOM etc., complete as per specification (PWD SR 2018-19/P.No.111/14.56) | m | 185.4 | 185.4 | 33.34 | False | None | None | False | None | False | 6181.236 | 0 |
| 2328942 | 68825 | None | code30 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. Vol- 2 (KPWD SR 2023-24/P.No.60/9.11) | Sqm | 915.67 | 915.67 | 102.4407 | False | None | None | False | None | False | 93801.875769 | 0 |
| 2328943 | 68825 | None | code31 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg/m2, including pointing in white cement mixed with pigment of matching shade complete. Vol- 2 (KPWD SR 2023-24/P.No.71/10.14) | Sqm | 1139.18 | 1139.18 | 159.575 | False | None | None | False | None | False | 181784.6485 | 0 |
| 2328944 | 68825 | None | code32 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Vol- 2 (KPWD SR 2023-24/P.No.100/12.13.1) | Cum | 101779.45 | 101779.45 | 0.54 | False | None | None | False | None | False | 54960.903 | 0 |
| 2328945 | 68825 | None | code33 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial Vol- 2 (KPWD SR 2023-24/P.No.105/12.57.6) | Sqm | 3421.66 | 3421.66 | 15.12 | False | None | None | False | None | False | 51735.4992 | 0 |
| 2328946 | 68825 | None | code34 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. Vol- 2 (KPWD SR 2023-24/P.No.104/12.51) | No | 1046.48 | 1046.48 | 8.0 | False | None | None | False | None | False | 8371.84 | 0 |
| 2328947 | 68825 | None | code35 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) &
1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Size 62 x 125mm Vol- 2 (KPWD SR 2023-24/P.No.111/12.93.2) | m | 786.92 | 786.92 | 136.8 | False | None | None | False | None | False | 107650.656 | 0 |
| 2328948 | 68825 | None | code36 | Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) - 30 mm thickness. Vol- 2 (KPWD SR 2023-24/P.No.112/12.94.1) | Sqm | 3589.55 | 3589.55 | 37.8 | False | None | None | False | None | False | 135684.99 | 0 |
| 2328949 | 68825 | None | code37 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete Vol- 2 (KPWD SR 2023-24/P.No.105/12.63) | No | 133.9 | 133.9 | 24.0 | False | None | None | False | None | False | 3213.6 | 0 |
| 2328950 | 68825 | None | code38 | Providing and fixing aluminium round shape handle of outer dia 100 mm with SS screws etc. complete as per direction of Engineer-in- charge: Anodized (AC 15 ) aluminium including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Vol- 2 (KPWD SR 2023-24/P.No.93/11.50.1) | No | 83.43 | 83.43 | 48.0 | False | None | None | False | None | False | 4004.64 | 0 |
| 2328951 | 68825 | None | code39 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge SS Aldrop 16mm dia, 200mm Vol- 2 (KPWD SR 2023-24/P.No.218/22.15.3) | No | 309.0 | 309.0 | 24.0 | False | None | None | False | None | False | 7416.0 | 0 |
| 2328952 | 68825 | None | code40 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. Vol- 2 (KPWD SR 2023-24/P.No.86/11.34B) | Kg | 188.49 | 188.49 | 181.44 | False | None | None | False | None | False | 34199.6256 | 0 |
| 2328953 | 68825 | None | code41 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Vol- 2 (KPWD SR 2023-24/P.No.48/8.40) | Sqm | 118.45 | 118.45 | 8.64 | False | None | None | False | None | False | 1023.408 | 0 |
| 2328954 | 68825 | None | code42 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded
Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made) Vol- 2 (KPWD SR 2023-24/P.No.110/12.90) | Sqm | 6936.02 | 6936.02 | 2.16 | False | None | None | False | None | False | 14981.8032 | 0 |
| 2328955 | 68825 | None | code43 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Vol- 2 (KPWD SR 2023-24/P.No.109/12.85) | Sqm | 5890.57 | 5890.57 | 6.48 | False | None | None | False | None | False | 38170.8936 | 0 |
| 2328956 | 68825 | None | code44 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 g/L as per specifications and as per directions of Engineer in charge. Vol- 2 (KPWD SR 2023-24/P.No.50/8.55.1) | Sqm | 57.68 | 57.68 | 36.288 | False | None | None | False | None | False | 2093.09184 | 0 |
| 2328957 | 68825 | None | code45 | Painting with oil type wood preservative of approved brand and manufacture :New work (two coats) to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge Vol- 2 (KPWD SR 2023-24/P.No.48/8.38) | Sqm | 41.2 | 41.2 | 36.288 | False | None | None | False | None | False | 1495.0656 | 0 |
| 2328958 | 68825 | None | code46 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Vol- 2 (KPWD SR 2023-24/P.No.85/11.28) | Kg | 581.95 | 581.95 | 152.32 | False | None | None | False | None | False | 88642.624 | 0 |
| 2328959 | 68825 | None | code47 | Honne wood beading 20x20 mm (KPWD SR 2023-24/P.No.A25/Sl No. 448) | m | 56.65 | 56.65 | 40.8 | False | None | None | False | None | False | 2311.32 | 0 |
| 2328960 | 68825 | None | code48 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 10 mm (KPWD SR 2023-24/P.No.69/10.6.2) | Each | 56.65 | 56.65 | 48.0 | False | None | None | False | None | False | 2719.2 | 0 |
| 2328961 | 68825 | None | code49 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type) Vol- 2 (KPWD SR 2023-24/P.No.107/12.75.1) | No | 283.25 | 283.25 | 24.0 | False | None | None | False | None | False | 6798.0 | 0 |
| 2328962 | 68825 | None | code50 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge SS Aldrop 16mm dia, 200mm Vol- 2 (KPWD SR 2023-24/P.No.218/22.15.3) | No | 309.0 | 309.0 | 8.0 | False | None | None | False | None | False | 2472.0 | 0 |
| 2328963 | 68825 | None | code51 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge SS Handles 200mm Vol- 2 (KPWD SR 2023-24/P.No.218/22.15.1) | No | 463.5 | 463.5 | 16.0 | False | None | None | False | None | False | 7416.0 | 0 |
| 2328964 | 68825 | None | code52 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge SS Tower Bolts 200x10mm Vol- 2 (KPWD SR 2023-24/P.No.219/22.15.6) | No | 154.5 | 154.5 | 16.0 | False | None | None | False | None | False | 2472.0 | 0 |
| 2328965 | 68825 | None | code53 | Providing and fixing magnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc. complete. Vol- 2 (KPWD SR 2023-24/P.No.105/12.65) | No | 60.77 | 60.77 | 8.0 | False | None | None | False | None | False | 486.16 | 0 |
| 2328966 | 68825 | None | code54 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. vol- 2 (KPWD SR 2023-24/P.No.105/12.58) | No | 123.6 | 123.6 | 8.0 | False | None | None | False | None | False | 988.8 | 0 |
| 2328967 | 68825 | None | code55 | Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete including cost of materials, labour, usage charges of machinery complete as per specifications. Vol- 2 (KPWD SR 2023-24/P.No.93/11.47) | No | 450.11 | 450.11 | 8.0 | False | None | None | False | None | False | 3600.88 | 0 |
| 2328968 | 68825 | None | code56 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. Vol- 2 (KPWD SR 2023-24/P.No.149/15.1) | Sqm | 841.51 | 841.51 | 132.96 | False | None | None | False | None | False | 111887.1696 | 0 |
| 2328969 | 68825 | None | code57 | Supplying and installation of Ready made precast concrete water tank of capacity 5000 Ltr, making good the same including testing of joints complete as per direction of Engineer in Charge. | Nos | 60000.0 | 60000.0 | 2.0 | False | None | None | False | None | False | 120000.0 | 0 |
| 2328970 | 68825 | None | code58 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. point wiring using class A Materials Short point upto 3 mts from tapping point to out let via switch box | Point | 269.0 | 269.0 | 12.0 | False | None | None | False | None | False | 3228.0 | 0 |
| 2328971 | 68825 | None | code59 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. point wiring using class A Materials Medium point above 3 mts upto 6mts from tapping point to outlet via switch box | Point | 379.0 | 379.0 | 4.0 | False | None | None | False | None | False | 1516.0 | 0 |
| 2328972 | 68825 | None | code60 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. point wiring using class A Materials Long point above 6 mts upto 10 mts from tapping point to outlet via switch box | Point | 555.0 | 555.0 | 4.0 | False | None | None | False | None | False | 2220.0 | 0 |
| 2328973 | 68825 | None | code61 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. point wiring using class A Materials Two outlet in a row above 3mts upto 6 mts from tapping point to outlet via switches | Point | 677.0 | 677.0 | 4.0 | False | None | None | False | None | False | 2708.0 | 0 |
| 2328974 | 68825 | None | code62 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. point wiring using class A Materials Three outlet in a row above 6 mts upto 10 mts from the tapping point to outlet via switches | Point | 989.0 | 989.0 | 4.0 | False | None | None | False | None | False | 3956.0 | 0 |
| 2328975 | 68825 | None | code63 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 1 - 3Way | Each | 103.0 | 103.0 | 8.0 | False | None | None | False | None | False | 824.0 | 0 |
| 2328976 | 68825 | None | code64 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 4 - 5Way | Each | 124.0 | 124.0 | 4.0 | False | None | None | False | None | False | 496.0 | 0 |
| 2328977 | 68825 | None | code65 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 6 Way | Each | 137.0 | 137.0 | 4.0 | False | None | None | False | None | False | 548.0 | 0 |
| 2328978 | 68825 | None | code66 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 8 Way | Each | 173.0 | 173.0 | 4.0 | False | None | None | False | None | False | 692.0 | 0 |
| 2328979 | 68825 | None | code67 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 10-12 Way | Each | 219.0 | 219.0 | 2.0 | False | None | None | False | None | False | 438.0 | 0 |
| 2328980 | 68825 | None | code68 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 16-18 Way | Each | 261.0 | 261.0 | 2.0 | False | None | None | False | None | False | 522.0 | 0 |
| 2328981 | 68825 | None | code69 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 1 - 3Way | Each | 138.0 | 138.0 | 2.0 | False | None | None | False | None | False | 276.0 | 0 |
| 2328982 | 68825 | None | code70 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 4 - 5Way | Each | 159.0 | 159.0 | 2.0 | False | None | None | False | None | False | 318.0 | 0 |
| 2328983 | 68825 | None | code71 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 6 Way | Each | 177.0 | 177.0 | 2.0 | False | None | None | False | None | False | 354.0 | 0 |
| 2328984 | 68825 | None | code72 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 8 Way | Each | 220.0 | 220.0 | 2.0 | False | None | None | False | None | False | 440.0 | 0 |
| 2328985 | 68825 | None | code73 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 10 / 12 Way | Each | 261.0 | 261.0 | 2.0 | False | None | None | False | None | False | 522.0 | 0 |
| 2328986 | 68825 | None | code74 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 16 / 18 Way | Each | 319.0 | 319.0 | 2.0 | False | None | None | False | None | False | 638.0 | 0 |
| 2328987 | 68825 | None | code75 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 1 to 3 Module | Each | 137.0 | 137.0 | 10.0 | False | None | None | False | None | False | 1370.0 | 0 |
| 2328988 | 68825 | None | code76 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 4 Module | Each | 161.0 | 161.0 | 6.0 | False | None | None | False | None | False | 966.0 | 0 |
| 2328989 | 68825 | None | code77 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 6 Module | Each | 175.0 | 175.0 | 6.0 | False | None | None | False | None | False | 1050.0 | 0 |
| 2328990 | 68825 | None | code78 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 8 Module | Each | 234.0 | 234.0 | 6.0 | False | None | None | False | None | False | 1404.0 | 0 |
| 2328991 | 68825 | None | code79 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 12/10Module | Each | 284.0 | 284.0 | 4.0 | False | None | None | False | None | False | 1136.0 | 0 |
| 2328992 | 68825 | None | code80 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 16 / 18 Way | Each | 344.0 | 344.0 | 4.0 | False | None | None | False | None | False | 1376.0 | 0 |
| 2328993 | 68825 | None | code81 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 amps one way switch | Each | 102.0 | 102.0 | 12.0 | False | None | None | False | None | False | 1224.0 | 0 |
| 2328994 | 68825 | None | code82 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 amps two way switch | Each | 166.0 | 166.0 | 8.0 | False | None | None | False | None | False | 1328.0 | 0 |
| 2328995 | 68825 | None | code83 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 Amps 3 way sockets | Each | 171.0 | 171.0 | 6.0 | False | None | None | False | None | False | 1026.0 | 0 |
| 2328996 | 68825 | None | code84 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 stepped fan Regulator's | Each | 357.0 | 357.0 | 4.0 | False | None | None | False | None | False | 1428.0 | 0 |
| 2328997 | 68825 | None | code85 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 16A One Way Switch | Each | 177.0 | 177.0 | 4.0 | False | None | None | False | None | False | 708.0 | 0 |
| 2328998 | 68825 | None | code86 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6/16 Amps universal sockets | Each | 156.0 | 156.0 | 10.0 | False | None | None | False | None | False | 1560.0 | 0 |
| 2328999 | 68825 | None | code87 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 32A DP switch | Each | 236.0 | 236.0 | 4.0 | False | None | None | False | None | False | 944.0 | 0 |
| 2329000 | 68825 | None | code88 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6A Bell push | Each | 326.0 | 326.0 | 2.0 | False | None | None | False | None | False | 652.0 | 0 |
| 2329001 | 68825 | None | code89 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 TV/Telephone Socket | Each | 337.0 | 337.0 | 2.0 | False | None | None | False | None | False | 674.0 | 0 |
| 2329002 | 68825 | None | code90 | Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 20 mm dia 2mm thick | Mtr | 66.0 | 66.0 | 100.0 | False | None | None | False | None | False | 6600.0 | 0 |
| 2329003 | 68825 | None | code91 | Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 25 mm dia 2mm thick | Mtr | 78.0 | 78.0 | 80.0 | False | None | None | False | None | False | 6240.0 | 0 |
| 2329004 | 68825 | None | code92 | Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 32 mm dia 2.5mm thick | Mtr | 103.0 | 103.0 | 70.0 | False | None | None | False | None | False | 7210.0 | 0 |
| 2329005 | 68825 | None | code93 | Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 20 mm dia 2mm thick | Mtr | 68.0 | 68.0 | 80.0 | False | None | None | False | None | False | 5440.0 | 0 |
| 2329006 | 68825 | None | code94 | Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 25 mm dia 2mm thick | Mtr | 79.0 | 79.0 | 70.0 | False | None | None | False | None | False | 5530.0 | 0 |
| 2329007 | 68825 | None | code95 | Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 32 mm dia 2.5mm thick | Mtr | 99.0 | 99.0 | 50.0 | False | None | None | False | None | False | 4950.0 | 0 |
| 2329008 | 68825 | None | code96 | Supplying and fixing PVC/metal conduit deep junction box . 19/20mm deep junction box | Each | 49.0 | 49.0 | 24.0 | False | None | None | False | None | False | 1176.0 | 0 |
| 2329009 | 68825 | None | code97 | Supplying and fixing PVC/metal conduit deep junction box . 25mm deep junction box | Each | 56.0 | 56.0 | 12.0 | False | None | None | False | None | False | 672.0 | 0 |
| 2329010 | 68825 | None | code98 | Supplying and fixing PVC/metal conduit deep junction box . 32mm deep junction box | Each | 61.0 | 61.0 | 16.0 | False | None | None | False | None | False | 976.0 | 0 |
| 2329011 | 68825 | None | code99 | FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 1.5 Sq.mm | Mtr | 26.0 | 26.0 | 100.0 | False | None | None | False | None | False | 2600.0 | 0 |
| 2329012 | 68825 | None | code100 | FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 2.5 sq.mm | Mtr | 42.0 | 42.0 | 80.0 | False | None | None | False | None | False | 3360.0 | 0 |
| 2329013 | 68825 | None | code101 | FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 4 sq.mm | Mtr | 63.0 | 63.0 | 70.0 | False | None | None | False | None | False | 4410.0 | 0 |
| 2329014 | 68825 | None | code102 | FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 6sq.mm | Mtr | 92.0 | 92.0 | 40.0 | False | None | None | False | None | False | 3680.0 | 0 |
| 2329015 | 68825 | None | code103 | FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 10sq.mm | Mtr | 167.0 | 167.0 | 32.0 | False | None | None | False | None | False | 5344.0 | 0 |
| 2329016 | 68825 | None | code104 | FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 16sq.mm | Mtr | 318.0 | 318.0 | 44.0 | False | None | None | False | None | False | 13992.0 | 0 |
| 2329017 | 68825 | None | code105 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure.6 Way TP & N | Each | 4940.0 | 4940.0 | 2.0 | False | None | None | False | None | False | 9880.0 | 0 |
| 2329018 | 68825 | None | code106 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure.4 Way SP & N | Each | 4038.0 | 4038.0 | 2.0 | False | None | None | False | None | False | 8076.0 | 0 |
| 2329019 | 68825 | None | code107 | Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2. 8 Way | Each | 12605.0 | 12605.0 | 2.0 | False | None | None | False | None | False | 25210.0 | 0 |
| 2329020 | 68825 | None | code108 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SP | Each | 415.0 | 415.0 | 2.0 | False | None | None | False | None | False | 830.0 | 0 |
| 2329021 | 68825 | None | code109 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DP | Each | 1060.0 | 1060.0 | 2.0 | False | None | None | False | None | False | 2120.0 | 0 |
| 2329022 | 68825 | None | code110 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A TPN | Each | 3088.0 | 3088.0 | 2.0 | False | None | None | False | None | False | 6176.0 | 0 |
| 2329023 | 68825 | None | code111 | Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V up to 300mA sensitivity on existing wood/ panel board. 32-40Amps 4 pole | Each | 5147.0 | 5147.0 | 2.0 | False | None | None | False | None | False | 10294.0 | 0 |
| 2329024 | 68825 | None | code112 | Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V up to 300mA sensitivity on existing wood/ panel board. 63Amps 4 pole | Each | 5545.0 | 5545.0 | 2.0 | False | None | None | False | None | False | 11090.0 | 0 |
| 2329025 | 68825 | None | code113 | Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 2' - 9/10 W | Each | 551.0 | 551.0 | 12.0 | False | None | None | False | None | False | 6612.0 | 0 |
| 2329026 | 68825 | None | code114 | Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 20/22 W | Each | 690.0 | 690.0 | 4.0 | False | None | None | False | None | False | 2760.0 | 0 |
| 2329027 | 68825 | None | code115 | Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 36/40 W | Each | 1269.0 | 1269.0 | 4.0 | False | None | None | False | None | False | 5076.0 | 0 |
| 2329028 | 68825 | None | code116 | Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. | Each | 1492.0 | 1492.0 | 8.0 | False | None | None | False | None | False | 11936.0 | 0 |
| 2329029 | 68825 | None | code117 | Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with 100W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source | Each | 9486.0 | 9486.0 | 2.0 | False | None | None | False | None | False | 18972.0 | 0 |
| 2329030 | 68825 | None | code118 | Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA. | Each | 119.0 | 119.0 | 16.0 | False | None | None | False | None | False | 1904.0 | 0 |
| 2329031 | 68825 | None | code119 | Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire. | Each | 432.0 | 432.0 | 8.0 | False | None | None | False | None | False | 3456.0 | 0 |
| 2329032 | 68825 | None | code120 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid Vol- 2 (PWD SR 2023-24/P.No.131/14.3.1) | Each | 6156.31 | 6156.31 | 2.0 | False | None | None | False | None | False | 12312.62 | 0 |
| 2329033 | 68825 | None | code121 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests Vol- 2 (PWD SR 2023-24/P.No.131/14.1.1) | Each | 5030.52 | 5030.52 | 24.0 | False | None | None | False | None | False | 120732.48 | 0 |
| 2329034 | 68825 | None | code122 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps Vol- 2 (PWD SR 2023-24/P.No.132/14.7.1) | Each | 3174.46 | 3174.46 | 8.0 | False | None | None | False | None | False | 25395.68 | 0 |
| 2329035 | 68825 | None | code123 | Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 g Vol- 2 (PWD SR 2023-24/P.No.137/14.37.1) | Each | 315.18 | 315.18 | 8.0 | False | None | None | False | None | False | 2521.44 | 0 |
| 2329036 | 68825 | None | code124 | Providing and fixing brass bib cock of approved quality : 15 mm nominal bore Vol- 2 (PWD SR 2023-24/P.No.117/13.2.1) | No | 294.58 | 294.58 | 8.0 | False | None | None | False | None | False | 2356.64 | 0 |
| 2329037 | 68825 | None | code125 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern Vol- 2 (PWD SR 2023-24/P.No.131/14.4.1) | Each | 4587.62 | 4587.62 | 8.0 | False | None | None | False | None | False | 36700.96 | 0 |
| 2329038 | 68825 | None | code126 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 Vol- 2 (PWD SR 2023-24/P.No.131/13.16) | No | 638.6 | 638.6 | 8.0 | False | None | None | False | None | False | 5108.8 | 0 |
| 2329039 | 68825 | None | code127 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. Vol- 2 (PWD SR 2023-24/P.No.136/14.31) | Each | 1256.6 | 1256.6 | 4.0 | False | None | None | False | None | False | 5026.4 | 0 |
| 2329040 | 68825 | None | code128 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15 mm nominal bore, 165 mm long, weighing not less than 110 g Vol- 2 (PWD SR 2023-24/P.No.120/13.17.3) | No | 229.69 | 229.69 | 8.0 | False | None | None | False | None | False | 1837.52 | 0 |
| 2329041 | 68825 | None | code129 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 20 mm nominal bore, 89 mm long, weighing not less than 88 g Vol- 2 (PWD SR 2023-24/P.No.120/13.18.2) | No | 148.32 | 148.32 | 8.0 | False | None | None | False | None | False | 1186.56 | 0 |
| 2329042 | 68825 | None | code130 | Concealed stop cock, 15 mm nominal bore, 108 mm long, weighing not less than 108 g 15 mm nominal bore, 107 mm long, weighing not less than 110 g Vol- 2 (PWD SR 2023-24/P.No.120/13.20.1) | No | 273.98 | 273.98 | 8.0 | False | None | None | False | None | False | 2191.84 | 0 |
| 2329043 | 68825 | None | code131 | Providing and fixing PTMT, push cock of approved quality and colour 15 mm nominal bore, 98 mm long, weighing not less than 75 g Vol- 2 (PWD SR 2023-24/P.No.120/13.21.1) | No | 131.84 | 131.84 | 8.0 | False | None | None | False | None | False | 1054.72 | 0 |
| 2329044 | 68825 | None | code132 | Providing and fixing PTMT grating of approved quality and colour. 125 mm nominal dia Vol- 2 (PWD SR 2023-24/P.No.120/13.22.1.2) | No | 45.32 | 45.32 | 16.0 | False | None | None | False | None | False | 725.12 | 0 |
| 2329045 | 68825 | None | code133 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia pipes Vol- 2 (PWD SR 2023-24/P.No.122/13.32.2) | m | 390.37 | 390.37 | 40.0 | False | None | None | False | None | False | 15614.8 | 0 |
| 2329046 | 68825 | None | code134 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal dia pipes Vol- 2 (PWD SR 2023-24/P.No.122/13.32.3) | m | 491.31 | 491.31 | 44.0 | False | None | None | False | None | False | 21617.64 | 0 |
| 2329047 | 68825 | None | code135 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32 mm nominal dia pipes Vol- 2 (PWD SR 2023-24/P.No.122/13.32.4) | m | 573.71 | 573.71 | 30.0 | False | None | None | False | None | False | 17211.3 | 0 |
| 2329048 | 68825 | None | code136 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 20 mm nominal dia Pipes Vol- 2 (PWD SR 2023-24/P.No.122/13.33.2) | m | 223.51 | 223.51 | 30.0 | False | None | None | False | None | False | 6705.3 | 0 |
| 2329049 | 68825 | None | code137 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 25 mm nominal dia Pipes Vol- 2 (PWD SR 2023-24/P.No.122/13.33.3) | m | 304.88 | 304.88 | 39.0 | False | None | None | False | None | False | 11890.32 | 0 |
| 2329050 | 68825 | None | code138 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 32 mm nominal dia Pipes Vol- 2 (PWD SR 2023-24/P.No.122/13.33.4) | m | 383.16 | 383.16 | 32.0 | False | None | None | False | None | False | 12261.12 | 0 |
| 2329051 | 68825 | None | code139 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 40 mm nominal dia Pipes Vol- 2 (PWD SR 2023-24/P.No.123/13.33.5) | m | 491.31 | 491.31 | 20.0 | False | None | None | False | None | False | 9826.2 | 0 |
| 2329052 | 68825 | None | code140 | Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark. For 32 mm dia GM (Copper alloy) Gate valves Vol- 5 (PWD SR 2023-24/P.No.133/11.15.4) | Each | 1378.14 | 1378.14 | 2.0 | False | None | None | False | None | False | 2756.28 | 0 |
| 2329053 | 68825 | None | code141 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40 mm dia Vol- 1 (PWD SR 2023-24/P.No.136/14.28.2.2) | Each | 94.76 | 94.76 | 16.0 | False | None | None | False | None | False | 1516.16 | 0 |
| 2329054 | 68825 | None | code142 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: PVC pipes 50mm dia., 6 kg/sqcm & class 5 Vol- 5 (PWD SR 2023-24/P.No.113/10.1.3) | m | 104.03 | 104.03 | 19.2 | False | None | None | False | None | False | 1997.376 | 0 |
| 2329055 | 68825 | None | code143 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: PVC pipes 75mm dia., 6 kg/sqcm & class 3 Vol- 5 (PWD SR 2023-24/P.No.113/10.1.5) | m | 226.6 | 226.6 | 80.0 | False | None | None | False | None | False | 18128.0 | 0 |
| 2329056 | 68825 | None | code144 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: PVC pipes 110mm dia., 6 kg/sqcm & class 3 Vol- 5 (PWD SR 2023-24/P.No.113/10.1.7) | m | 423.33 | 423.33 | 90.0 | False | None | None | False | None | False | 38099.7 | 0 |
| 2329057 | 68825 | None | code145 | Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.. Vol- 5 (PWD SR 2023-24/P.No.191/16.9) | Each | 5617.62 | 5617.62 | 4.0 | False | None | None | False | None | False | 22470.48 | 0 |
| 2329058 | 68825 | None | code146 | Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0 cm X 4.0 cm with all fitting arrangements & all necessary accessories complete Vol- 5 (PWD SR 2023-24/P.No.128/13.63) | Each | 251.32 | 251.32 | 44.0 | False | None | None | False | None | False | 11058.08 | 0 |
| 2329059 | 68825 | None | code147 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. Vol- 5 (PWD SR 2023-24/P.No.123/13.34) | Ltr | 9.27 | 9.27 | 2000.0 | False | None | None | False | None | False | 18540.0 | 0 |