| 2338375 | 69123 | None | Vol-1 Pg 5 It-1.4 | Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. | CUBIC METER | 254.1 | 254.1 | 67.73 | False | None | None | False | None | False | 17210.193 | 0 |
| 2338376 | 69123 | None | Vol-1 Pg-15 It-2.1.4 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. . Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates. | CUBIC METER | 6527.85 | 6527.85 | 21.5324 | False | None | None | False | None | False | 140560.27734 | 0 |
| 2338377 | 69123 | None | Vol-2 Pg-9 It-5.1.1 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with 5.1.1 Cement mortar 1:6 (1 cement : 6 coarse sand). | CUBIC METER | 5891.55 | 5891.55 | 36.0 | False | None | None | False | None | False | 212095.8 | 0 |
| 2338378 | 69123 | None | Vol-1 Pg-18 It-2.11 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. | Tonne | 82961.55 | 82961.55 | 0.76 | False | None | None | False | None | False | 63050.778 | 0 |
| 2338379 | 69123 | None | Vol-1 Pg-16 It-2.4.2 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | CUBIC METER | 6639.2 | 6639.2 | 4.32 | False | None | None | False | None | False | 28681.344 | 0 |
| 2338380 | 69123 | None | Vol-1 pg 111 Appendix I, No: 1 (a) | Form work as per recommendations of technical working group, rates for formwork shall be added on perentage basis to the finished concrete item rate. For Foundation Isolated type consider 8% etc complete as directed by Engineer incharge of the work. | CUBIC METER | 531.13 | 531.13 | 4.32 | False | None | None | False | None | False | 2294.4816 | 0 |
| 2338381 | 69123 | None | Vol-1 Pg-16 It-2.5.1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. | CUBIC METER | 6961.5 | 6961.5 | 16.04 | False | None | None | False | None | False | 111662.46 | 0 |
| 2338382 | 69123 | None | Vol-1 pg 111 Appendix I, No: 9 | Form work as per recommendations of technical working group, rates for formwork shall be added on perentage basis to the finished concrete item rate. For columns consider 70 % etc complete as directed by Engineer incharge of the work | CUBIC METER | 4873.05 | 4873.05 | 16.04 | False | None | None | False | None | False | 78163.722 | 0 |
| 2338383 | 69123 | None | Vol-1 Pg-7 It-1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | CUBIC METER | 279.3 | 279.3 | 24.0 | False | None | None | False | None | False | 6703.2 | 0 |
| 2338384 | 69123 | None | Vol-2 Pg-17 It-6.32 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications | Sqm | 1375.5 | 1375.5 | 133.2 | False | None | None | False | None | False | 183216.6 | 0 |
| 2338385 | 69123 | None | Vol-2 Pg-41 It-8.1.1 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per
directions of Engineer-in-charge. | Sqm | 267.75 | 267.75 | 288.0 | False | None | None | False | None | False | 77112.0 | 0 |
| 2338386 | 69123 | None | Vol-2 Pg-50 It-8.52.2 | Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two coats as per specifiations and as per directions of Engineer in charge | Sqm | 79.8 | 79.8 | 557.0 | False | None | None | False | None | False | 44448.6 | 0 |
| 2338387 | 69123 | None | Vol-2 Pg-188 It-19.10.1 | Dismantling dressed stone work ashlar face stone work, marble work or precast concrete work manually/ by mechanical means including stacking of serviceable and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge | CUBIC METER | 1051.05 | 1051.05 | 21.6 | False | None | None | False | None | False | 22702.68 | 0 |
| 2338388 | 69123 | None | Vol-2 Pg-193 It-19.55 | Dismantling old plaster or skirting raking out joints and cleaning thesurface for plaster including disposal of rubbish to the dumping ground to the appropriate disposal area as per direction of Engineer-in-charge. | Sqm | 38.85 | 38.85 | 64.0 | False | None | None | False | None | False | 2486.4 | 0 |
| 2338389 | 69123 | None | Vol-2 Pg-189 It-19.27 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material to the appropriate disposal area as per direction of Engineer-in-charge. | Sqm | 53.55 | 53.55 | 40.0 | False | None | None | False | None | False | 2142.0 | 0 |
| 2338390 | 69123 | None | Vol-2 Pg-14 It-6.14 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineerincharge of work. | Sqm | 1113.0 | 1113.0 | 39.825 | False | None | None | False | None | False | 44325.225 | 0 |
| 2338391 | 69123 | None | Vol-2 Pg-197 It-20.1 | Making the opening in brick masonry for door/window/clerestory window including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete, to match existing surface i/c disposal of mulba/ rubbish to the nearest municipal dumping ground, all complete as per direction of Engineer-in-Charge | Sqm | 1098.3 | 1098.3 | 3.78 | False | None | None | False | None | False | 4151.574 | 0 |
| 2338392 | 69123 | None | Vol-2 Pg-21 It-7.1 | Providing & fixing corrugated G.S. sheet roofing including vertical /curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete as per design drawings (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required as per the direction of Engineer in charge. | Sqm | 922.95 | 922.95 | 40.0 | False | None | None | False | None | False | 36918.0 | 0 |
| 2338393 | 69123 | None | Vol-2 Pg-78 It-11.6.1 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 2764.65 | 2764.65 | 27.0 | False | None | None | False | None | False | 74645.55 | 0 |
| 2338394 | 69123 | None | Vol-5 Pg-120 It-10.14.11 | Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete. | Mtr | 375.9 | 375.9 | 70.0 | False | None | None | False | None | False | 26313.0 | 0 |
| 2338395 | 69123 | None | Vol-5 Pg-117 It-10.9 | Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments | Each | 317.1 | 317.1 | 15.0 | False | None | None | False | None | False | 4756.5 | 0 |
| 2338396 | 69123 | None | Vol-2 Pg-125 It-13.51 | Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) with C.I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design :With common burnt clay (non modular) bricks of class designation 3. | Each | 1791.3 | 1791.3 | 10.0 | False | None | None | False | None | False | 17913.0 | 0 |
| 2338397 | 69123 | None | Vol-2 Pg-50 It-8.54.1 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. One coat as per specifications and as per directions of Engineer in charge | Sqm | 76.65 | 76.65 | 384.739 | False | None | None | False | None | False | 29490.24435 | 0 |
| 2338398 | 69123 | None | Vol-2 Pg-50 It-8.53.1 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 g/L, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. One coat as per specifications and as per directions of Engineer in charge | Sqm | 69.3 | 69.3 | 373.29 | False | None | None | False | None | False | 25868.997 | 0 |
| 2338399 | 69123 | None | Vol-3 Pg-9 It-2.4 | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal ofunserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness | Sqm | 15.75 | 15.75 | 375.0 | False | None | None | False | None | False | 5906.25 | 0 |
| 2338400 | 69123 | None | Vol-3 Pg-17 It-3.1 | Removal of Unserviceable Soil with Disposal upto a suitable distance as directed by the Engineer incharge of work | CUBIC METER | 89.25 | 89.25 | 195.75 | False | None | None | False | None | False | 17470.6875 | 0 |
| 2338401 | 69123 | None | Vol-1 Pg-7 It-1.8 | Construction of Embankment by excavating the available approved Gravel/ Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces requiredto complete the work. | CUBIC METER | 497.7 | 497.7 | 116.7 | False | None | None | False | None | False | 58081.59 | 0 |
| 2338402 | 69123 | None | Vol-3 Pg-52 It-6.8.5 | Providing and laying Permeable Cement Concrete Paver Block for Pedestrian Footpaths of approved shape and colour, laid in required pattern and including over 30mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge | Sqm | 1069.95 | 1069.95 | 82.62 | False | None | None | False | None | False | 88399.269 | 0 |
| 2338403 | 69123 | None | Vol-2 Pg-104 It-12.54 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge | Mtr | 333.9 | 333.9 | 6.8 | False | None | None | False | None | False | 2270.52 | 0 |
| 2338404 | 69123 | None | Vol-2 Pg-104 It-12.53 | Providing & fixing 30mm thick factory made rigid foam Panelled Door Shutters made from M.S.tube of 19 gauge thickness, size 19x19mm for stiles and 15x15mm for top & bottom rails, covered with heat moulded PVC C channel of 5mm thick sheet & 30 x 50mm wide to form stiles & 5mm thick & 75mm wide PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick 20mm wide PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet fitted in the M.S. Frame, Sealed to the stiles & rails with 5x30mm PVC sheet beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75 mm Aluminium hinges | Sqm | 1667.4 | 1667.4 | 1.725 | False | None | None | False | None | False | 2876.265 | 0 |
| 2338405 | 69123 | None | Vol-2 Pg-220 It-22.26 | Providing & supplying Water resistant No dust Plastic Dust pan of good quality as per direction of Engineer in charge. | Nos | 42.0 | 42.0 | 5.0 | False | None | None | False | None | False | 210.0 | 0 |
| 2338406 | 69123 | None | Vol-2 Pg-220 It-22.27 | Providing & supplying hands free squeeze Micro fibre Flat spin Mop with 360 degree flexible head and super absorbent fibre of good quality as per direction of Engineer in charge | Nos | 892.5 | 892.5 | 2.0 | False | None | None | False | None | False | 1785.0 | 0 |
| 2338407 | 69123 | None | Vol-2 Pg-220 It-22.28 | Providing & supplying Carpet/Mat of 800+ gsm with stain proof, flexible and super absorbent fibre of good quality as per direction of Engineer in charge | Sqm | 1470.0 | 1470.0 | 2.5 | False | None | None | False | None | False | 3675.0 | 0 |
| 2338408 | 69123 | None | Vol-2 Pg-221 It-22.50 | Providing & supplying Floor & Surface cleaners Non corrosive with chemicals Hydrochloric acid, Butyl oleytamine and others which are water soluble and capable of removing hard and soft stains and dirt as per direction of Engineer in charge of work | l | 114.45 | 114.45 | 5.0 | False | None | None | False | None | False | 572.25 | 0 |
| 2338409 | 69123 | None | Vol-2 Pg-221 It-22.51 | Providing & supplying Toilet cleaner of reputed make capable of killing bacteria, germs as per direction of Engineer in charge of work | l | 231.0 | 231.0 | 5.0 | False | None | None | False | None | False | 1155.0 | 0 |
| 2338410 | 69123 | None | Vol-2 Pg-206 It-20.88 | Repairs to plaster in patches of 2.5 m2 and less in walls, ceilings 10 to 20mm thick in cement mortar 1:3 including cutting the patches in proper shape and replastering the surface of the wall including disposal of rubbish with a lead of 50m including curing cost of materials, labour, complete as per specification. | Sqm | 418.95 | 418.95 | 76.5 | False | None | None | False | None | False | 32049.675 | 0 |
| 2338411 | 69123 | None | Vol-2 Pg-52 It-8.69 | Re-lettering with black Japan paint of approved brand and manufac ture. to give an even shade including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | cm | 2.63 | 2.63 | 998.0 | False | None | None | False | None | False | 2624.74 | 0 |
| 2338412 | 69123 | None | Vol-2 Pg-89 It-11.37.3 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasketetc. complete as per the architectural drawings and the directions ofengineer-in-charge . (Cost of aluminium snap beading shall be paid in basicitem):With float glass panes of 8 mm thickness (weight not less than 20kg/ m²) including cost of materials, labour, usage charges of machinerycomplete as per specifications | Sqm | 1370.25 | 1370.25 | 84.37 | False | None | None | False | None | False | 115607.9925 | 0 |
| 2338413 | 69123 | None | Vol-2 Pg-106 It-12.67 | Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated brackets (25mm dia heavy pipe) | Mtr | 463.05 | 463.05 | 22.4 | False | None | None | False | None | False | 10372.32 | 0 |
| 2338414 | 69123 | None | Vol-2 Pg-219 It-22.24 | Providing & fixing 100% Polyester Curtains with specification of regular wash as per direction of Engineer in charge | Sqm | 1260.0 | 1260.0 | 29.1 | False | None | None | False | None | False | 36666.0 | 0 |
| 2338415 | 69123 | None | Vol-6 Pg-2 It-1 .1 .1 | SupplyingheavygaugePVCconduitpipe.......dia.......mmthickconfirmingtoIS2509withsuitablesizebends,junctionboxes,adhesivepasteetc,andfixingusinginvertedwoodplugsincaseofRCCceilingandRCCwall/stonestructureorrawlplugsincaseofbrickwallsandcementplasteringthedamagedportionusingheavygauge saddles at an interval of 700mm using NF screws.(19/20 mm dia 2 mm thick) | Mtr | 72.45 | 72.45 | 30.0 | False | None | None | False | None | False | 2173.5 | 0 |
| 2338416 | 69123 | None | Vol-6 Pg-5 It-2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, 2.5SQMM multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP. | Mtr | 44.1 | 44.1 | 35.0 | False | None | None | False | None | False | 1543.5 | 0 |
| 2338417 | 69123 | None | Vol-6 Pg-5 It-2.3.4 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, 4 SQMM multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP. | Mtr | 66.15 | 66.15 | 20.0 | False | None | None | False | None | False | 1323.0 | 0 |
| 2338418 | 69123 | None | Vol-6 Pg-47 It-11.10.5 | Supplying & fixing of Surface mounting type retrofit type -LED tube W
comprising of LED linear source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per W, life 25000 burning hours and Compliance to IS
10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driverintegrated in the system, with PF 0.95, power loss should 5% of lamp Wage.,short circuit & open circuit protection to be integrated in the circuit, THD lessthan 20%, Life as per LM 79. The operating input voltage should be between 130to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratorywith 2 years Warranty against any manufacturing defect working under standardelectrical condition | Each | 717.15 | 717.15 | 5.0 | False | None | None | False | None | False | 3585.75 | 0 |
| 2338419 | 69123 | None | Vol-6 Pg-56 It-13.7.1 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps | Each | 128.1 | 128.1 | 5.0 | False | None | None | False | None | False | 640.5 | 0 |
| 2338420 | 69123 | None | Vol-6 Pg-30 It-6.3.1 | Supplying capacitor type ceiling fan complete with down rodblades, shackle, canopies etc, for operation on 230 V, 50 cycles.Single phase AC supply conforming to ISS-374- 1979 and withdouble ball bearing system | Each | 3133.2 | 3133.2 | 4.0 | False | None | None | False | None | False | 12532.8 | 0 |
| 2338421 | 69123 | None | Vol-6 Pg-57 It-13.12 | Extra length of GI pipe of class B 19mm dia for down rod. | Mtr | 206.85 | 206.85 | 1.5 | False | None | None | False | None | False | 310.275 | 0 |
| 2338422 | 69123 | None | Vol-6 Pg-57 It-13.10 | Fixing a ceiling / Wall mounting fan of all capacities and alltypes to the existing 'S'' hook with fan regulator to the existingboard together with supplying and fixing 5 A. ceiling rose,necessary length of 23 / 0.0076 inch PVC insulated twintwisted copper wire and wiring. | Each | 179.55 | 179.55 | 4.0 | False | None | None | False | None | False | 718.2 | 0 |
| 2338423 | 69123 | None | Vol-6 Pg-46 It-11.8.2 | SupplyofLEDStreetlightluminairewithpressurediecastaluminiumhousingbodyforoptimalthermaldissipation.LampcompartmentcomprisingofantiglarecleardiffuserwithInjectionmouldedpolycarbonatematerial,deliveringsuperiorlightoutputRatedlifeBurningHrs50000hrLumenMaintenanceof70 percent ,maximumlightintensityshouldbebetween60degreesto70degrees.CCT 5500K,IP66opticalandelectricalcompartment&impactresistanceofcompleteluminaire IK08.PowerFactor 0.9withmains,SurgeProtection-Min5KValongwithOvervoltage/Overload,shortcircuit/miss-wiringprotection.Compatibleforpolemountingwithouterdiaof40mmto50mm.UniversalVoltagedrivertooperatewidevoltagerangefrom100Vto270V50/60Hzapplication.CompliancetoIS10322/IEC60598,LM79&LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with singlescrewtoensureeaseofmaintenanceatthesightsitelocationwithminimizedminimaltools.LEDLightfixturewithWSystemPowerconsumption.LEDEfficiency1301m/w,nominalCRI75.Luminairemanufacturershouldhavein-housefacilityaccreditedbyNABL/CPRI&anyGovernmentcertifiedagency&Design&DevelopmentfacilitycertifiedbyISO9001:2008.Housingwithsupplierwordmark/nameshallbeEngraved/Embossingonthediecasthousing/Bodypart.Warrantyof2YearsagainstanymanufacturingdefectworkingunderstandardelectricalconditionsasmentionedaboveshouldbegivenbyLEDmanufacturer&Cree/Nichia/Lumileds/Osram make LED Source.
PWD | Each | 4225.2 | 4225.2 | 5.0 | False | None | None | False | None | False | 21126.0 | 0 |
| 2338424 | 69123 | None | Vol-6 Pg-43 It-11.1 | Supplying & fixing - flexible LED Strip Light ..... W Power consumption in 5 ms length CCT6500 degree K, CRI 70%. efficacy 80 lumen per W, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver non integrated, with PF 0.95, power loss should 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved with 2 years Warranty against any manufacturing defect working under standard electrical conditio | Mtr | 1355.55 | 1355.55 | 10.0 | False | None | None | False | None | False | 13555.5 | 0 |