| 2238440 | 65527 | None | code01 | Construction of Two Class Rooms in First Floor to Kabberpete Gps School at Town in Hosapete taluk.Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. | Cum | 8046.61 | 8046.61 | 9.52 | False | None | None | False | None | False | 76603.7272 | 0 |
| 2238441 | 65527 | None | code02 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. | Cum | 8786.03 | 8786.03 | 24.09 | False | None | None | False | None | False | 211655.4627 | 0 |
| 2238442 | 65527 | None | code03 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) | Cum | 10196.66 | 10196.66 | 0.45 | False | None | None | False | None | False | 4588.497 | 0 |
| 2238443 | 65527 | None | code04 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or
more Steel reinforcement for R.C.C. work including straightening,
cutting, bending, placing in position, binding and anchoring to adjacent
members whereever necessary complete as per Design cost
of material labour usage charges complete as per specifications. (The laps and wastages shall not be measured separately | Kgs | 95.45 | 95.45 | 2685.3 | False | None | None | False | None | False | 256311.885 | 0 |
| 2238444 | 65527 | None | code05 | Providing Brick work with common burnt clay modular bricks of class
designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 9184.99 | 9184.99 | 41.4 | False | None | None | False | None | False | 380258.586 | 0 |
| 2238445 | 65527 | None | code06 | Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 131716.22 | 131716.22 | 0.08 | False | None | None | False | None | False | 10537.2976 | 0 |
| 2238446 | 65527 | None | code07 | Providing and fixing in position fully panelled Mathi/Nandi wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures) | Sqm | 4287.6 | 4287.6 | 5.04 | False | None | None | False | None | False | 21609.504 | 0 |
| 2238447 | 65527 | None | code08 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding | Kgs | 178.16 | 178.16 | 181.44 | False | None | None | False | None | False | 32325.3504 | 0 |
| 2238448 | 65527 | None | code09 | Providing & fixing of 2.5 track x 2panel sliding windows made out of multi chambered UPVC Matching to RAL9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 81mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm x 57mm and mesh sash of size with GI reinforcement of 1.5mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 1.8-2.0mm. Maximum possible size 1519mm x 1519mm (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) | Sqm | 6947.34 | 6947.34 | 8.64 | False | None | None | False | None | False | 60025.0176 | 0 |
| 2238449 | 65527 | None | code10 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 338.04 | 338.04 | 115.92 | False | None | None | False | None | False | 39185.5968 | 0 |
| 2238450 | 65527 | None | code11 | Providing 20 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 469.28 | 469.28 | 296.06 | False | None | None | False | None | False | 138935.0368 | 0 |
| 2238451 | 65527 | None | code12 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. G.I. pipes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kgs | 178.16 | 178.16 | 240.0 | False | None | None | False | None | False | 42758.4 | 0 |
| 2238452 | 65527 | None | code13 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm | Sqm | 1214.27 | 1214.27 | 105.1 | False | None | None | False | None | False | 127619.777 | 0 |
| 2238453 | 65527 | None | code14 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. | Sqm | 1536.65 | 1536.65 | 44.18 | False | None | None | False | None | False | 67889.197 | 0 |
| 2238454 | 65527 | None | code15 | Lettering with black Japan paint of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | cm | 4.24 | 4.24 | 1200.0 | False | None | None | False | None | False | 5088.0 | 0 |
| 2238455 | 65527 | None | code16 | Providing lime wash on walls with one coat with lime of approved quality to give an even shade, including cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 10.61 | 10.61 | 379.12 | False | None | None | False | None | False | 4022.4632 | 0 |
| 2238456 | 65527 | None | code17 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 171.8 | 171.8 | 115.92 | False | None | None | False | None | False | 19915.056 | 0 |
| 2238457 | 65527 | None | code18 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drop and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 264.71 | 264.71 | 402.46 | False | None | None | False | None | False | 106535.1866 | 0 |
| 2238458 | 65527 | None | code19 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 177.1 | 177.1 | 10.08 | False | None | None | False | None | False | 1785.168 | 0 |
| 2238459 | 65527 | None | code20 | Concealed Conduit System : Supplying 19/20 mm dia 2 mm 2.5 mm thick heavy gauge PVC conduit pipe with suitable size bends metal / PC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18 SWG GI fish wire wherever necessary. | Mtr | 66.0 | 66.0 | 80.0 | False | None | None | False | None | False | 5280.0 | 0 |
| 2238460 | 65527 | None | code21 | Point wiring using copper wire with switch Supplying and wiring adopting loop system in existing PVC Conduit /casing caping using copper PVC insulated multi strand 2x1.5Sqmm copper wire with a 6Amps flush type SP control switch shall be fixed on the exisiting plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete for each outlet.Point wiring using class A Materials: for Short point upto 3Mtr from tapping point to out let via switch Item No. 2.1, Page No.5.and as per directed by Engineer Incharge of Work.a. Long point from 6mtr to 10 Mtr from tapping to via switch | Point | 394.0 | 394.0 | 6.0 | False | None | None | False | None | False | 2364.0 | 0 |
| 2238461 | 65527 | None | code22 | Wiring for lighting/power circuit using one of PVC insulated 1100v grade multis and Copper conductor single core cable in open or consealed system of wiring as per IS-694:1990 & confirming to GTP of Group-B . Group B Materials and as per directed by Engineer Incharge of Work.c.6 Sqmm | Mtr | 117.0 | 117.0 | 80.0 | False | None | None | False | None | False | 9360.0 | 0 |
| 2238462 | 65527 | None | code23 | Supplying Patti type Flourcent tube light fitting of 2' suitable for 14 watts flour cent tube fitting made out of M.S. Sheet and stove enameled with loss open construction copper wound ferromagnetic ballast starter locking type brass contract holders moulded on double fold type sheet base fully wired to use on 230 volts AC supply including T5 lamp. Item No.4.5, Page no.20.and as per directed by Engineer Incharge of Work | Each | 1269.0 | 1269.0 | 8.0 | False | None | None | False | None | False | 10152.0 | 0 |
| 2238463 | 65527 | None | code24 | Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating andI S: 374/79 and alsocomply with IS: 1709/1984 with latest amendment Rated voltage220V/50 Hz, Rated power input 48W+/-10%,Rated current As per IS:374/79, Rated power factor 0.9l agging (min), Rated speed 350+/-10%RPM, Rated airdelivery 210+/-10% Cubic Meter Minimum, Rated service value 4.2 CMM /W,Three Blade sofblade leaf 1.05mm thick Aluminium Alloy sheet, Class B motor insulation ,210Micro Amp, Power input,W¤t, Air Delivery & Fan Speed asperIS:374/1979 with latest amendment, 2year manufacturerWarranty. | Each | 2677.0 | 2677.0 | 4.0 | False | None | None | False | None | False | 10708.0 | 0 |
| 2238464 | 65527 | None | code25 | Supplying and fixing PVC / metal conduit accessories Deep type junction box a) 19/20 mm dia 2 mm thick | Each | 49.0 | 49.0 | 6.0 | False | None | None | False | None | False | 294.0 | 0 |
| 2238465 | 65527 | None | code26 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12 mm thick wood, after due groove cutting, necessary masonry patch work complete a)12"x12x3" (300x300x76 mm) | Each | 120.0 | 120.0 | 6.0 | False | None | None | False | None | False | 720.0 | 0 |
| 2238466 | 65527 | None | code27 | Point wiring using copper wire with switch Supplying and wiring adopting loop system in existing PVC conduit / casing caping using copper PVC insulated multi strand 2x1 5 sqmm copper wire with a 6 Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shaft be terminated with sufficient boose length in a wood / PVC round block complete for each outlet.a) Shoft point upto 3 Mtr from tapping point to outlet via switch | Each | 285.0 | 285.0 | 5.0 | False | None | None | False | None | False | 1425.0 | 0 |
| 2238467 | 65527 | None | code28 | Point wiring using copper wire with switch Supplying and wiring adopting loop system in existing PVC conduit / casing caping using copper PVC insulated multi strand 2x1 5 sqmm copper wire with a 6 Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shaft be terminated with sufficient boose length in a wood / PVC round block complete for each outlet.b) Medium point upto 3 Mtr from tapping point to outlet via switch | Each | 379.0 | 379.0 | 5.0 | False | None | None | False | None | False | 1895.0 | 0 |
| 2238468 | 65527 | None | code29 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator dimmer / telephone socket etc on existing modular switch plate. | Each | 102.0 | 102.0 | 10.0 | False | None | None | False | None | False | 1020.0 | 0 |
| 2238469 | 65527 | None | code30 | Supplying and fixing 3 mm thick hylum plastic sheet etc complete with necessary nitches and screws etc complete. | cm | 0.41 | 0.41 | 552.0 | False | None | None | False | None | False | 226.32 | 0 |