createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1705734588527
version4
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeONE_COVER
evaluationTypeTextOne Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee500.00
emd48750.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose17-02-2024 17:00:00
tenderQueryClose16-02-2024 17:00:00
technicalBidOpenNone
publishedDate30-01-2024 17:42:52
publishedByPostRDPR_EE_DIV_VJN
publishedByUserKPE12111 - J R PAMPAPATHI
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonEE OFFICE
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber9482100616
tenderSupplierListNone
tenderSchedule
createdTs1705734588570
version6
createdDateNone
modifiedDateNone
tenderNumberRDPR/2023-24/BD/WORK_INDENT3562
titleConstruction of Two Class Rooms in First Floor to Kabberpete Gps School at Town in Hosapete taluk
descriptionConstruction of Two Class Rooms in First Floor to Kabberpete Gps School at Town in Hosapete taluk
categoryWORKS
categoryTextWorks
ecv1948290.39
deptNameRural Development and Panchayat Raj Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location943
locationNameRDPR Division Office Vijayanagara
provisionalAmount1950000.0
groupOverheadTotal297196.84
fileNumberPRED/SUB/HPT/AE/KKRDBGRANT/2021-22
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17057345890000NoneNoneBuildingsConstruction of Two Class Rooms in First Floor to Kabberpete Gps School at Town in Hosapete taluk1651093.55
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
223844065527Nonecode01Construction of Two Class Rooms in First Floor to Kabberpete Gps School at Town in Hosapete taluk.Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.Cum8046.618046.619.52FalseNoneNoneFalseNoneFalse76603.72720
223844165527Nonecode02Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.Cum8786.038786.0324.09FalseNoneNoneFalseNoneFalse211655.46270
223844265527Nonecode03Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)Cum10196.6610196.660.45FalseNoneNoneFalseNoneFalse4588.4970
223844365527Nonecode04Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design cost of material labour usage charges complete as per specifications. (The laps and wastages shall not be measured separatelyKgs95.4595.452685.3FalseNoneNoneFalseNoneFalse256311.8850
223844465527Nonecode05Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum9184.999184.9941.4FalseNoneNoneFalseNoneFalse380258.5860
223844565527Nonecode06Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications.Cum131716.22131716.220.08FalseNoneNoneFalseNoneFalse10537.29760
223844665527Nonecode07Providing and fixing in position fully panelled Mathi/Nandi wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures)Sqm4287.64287.65.04FalseNoneNoneFalseNoneFalse21609.5040
223844765527Nonecode08Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingKgs178.16178.16181.44FalseNoneNoneFalseNoneFalse32325.35040
223844865527Nonecode09Providing & fixing of 2.5 track x 2panel sliding windows made out of multi chambered UPVC Matching to RAL9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 81mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm x 57mm and mesh sash of size with GI reinforcement of 1.5mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 1.8-2.0mm. Maximum possible size 1519mm x 1519mm (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm6947.346947.348.64FalseNoneNoneFalseNoneFalse60025.01760
223844965527Nonecode10Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm338.04338.04115.92FalseNoneNoneFalseNoneFalse39185.59680
223845065527Nonecode11Providing 20 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm469.28469.28296.06FalseNoneNoneFalseNoneFalse138935.03680
223845165527Nonecode12Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. G.I. pipes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kgs178.16178.16240.0FalseNoneNoneFalseNoneFalse42758.40
223845265527Nonecode13Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mmSqm1214.271214.27105.1FalseNoneNoneFalseNoneFalse127619.7770
223845365527Nonecode14Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.Sqm1536.651536.6544.18FalseNoneNoneFalseNoneFalse67889.1970
223845465527Nonecode15Lettering with black Japan paint of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.cm4.244.241200.0FalseNoneNoneFalseNoneFalse5088.00
223845565527Nonecode16Providing lime wash on walls with one coat with lime of approved quality to give an even shade, including cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm10.6110.61379.12FalseNoneNoneFalseNoneFalse4022.46320
223845665527Nonecode17Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm171.8171.8115.92FalseNoneNoneFalseNoneFalse19915.0560
223845765527Nonecode18Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drop and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm264.71264.71402.46FalseNoneNoneFalseNoneFalse106535.18660
223845865527Nonecode19Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm177.1177.110.08FalseNoneNoneFalseNoneFalse1785.1680
223845965527Nonecode20Concealed Conduit System : Supplying 19/20 mm dia 2 mm 2.5 mm thick heavy gauge PVC conduit pipe with suitable size bends metal / PC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18 SWG GI fish wire wherever necessary.Mtr66.066.080.0FalseNoneNoneFalseNoneFalse5280.00
223846065527Nonecode21Point wiring using copper wire with switch Supplying and wiring adopting loop system in existing PVC Conduit /casing caping using copper PVC insulated multi strand 2x1.5Sqmm copper wire with a 6Amps flush type SP control switch shall be fixed on the exisiting plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete for each outlet.Point wiring using class A Materials: for Short point upto 3Mtr from tapping point to out let via switch Item No. 2.1, Page No.5.and as per directed by Engineer Incharge of Work.a. Long point from 6mtr to 10 Mtr from tapping to via switchPoint394.0394.06.0FalseNoneNoneFalseNoneFalse2364.00
223846165527Nonecode22Wiring for lighting/power circuit using one of PVC insulated 1100v grade multis and Copper conductor single core cable in open or consealed system of wiring as per IS-694:1990 & confirming to GTP of Group-B . Group B Materials and as per directed by Engineer Incharge of Work.c.6 SqmmMtr117.0117.080.0FalseNoneNoneFalseNoneFalse9360.00
223846265527Nonecode23Supplying Patti type Flourcent tube light fitting of 2' suitable for 14 watts flour cent tube fitting made out of M.S. Sheet and stove enameled with loss open construction copper wound ferromagnetic ballast starter locking type brass contract holders moulded on double fold type sheet base fully wired to use on 230 volts AC supply including T5 lamp. Item No.4.5, Page no.20.and as per directed by Engineer Incharge of WorkEach1269.01269.08.0FalseNoneNoneFalseNoneFalse10152.00
223846365527Nonecode24Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating andI S: 374/79 and alsocomply with IS: 1709/1984 with latest amendment Rated voltage220V/50 Hz, Rated power input 48W+/-10%,Rated current As per IS:374/79, Rated power factor 0.9l agging (min), Rated speed 350+/-10%RPM, Rated airdelivery 210+/-10% Cubic Meter Minimum, Rated service value 4.2 CMM /W,Three Blade sofblade leaf 1.05mm thick Aluminium Alloy sheet, Class B motor insulation ,210Micro Amp, Power input,W&current, Air Delivery & Fan Speed asperIS:374/1979 with latest amendment, 2year manufacturerWarranty.Each2677.02677.04.0FalseNoneNoneFalseNoneFalse10708.00
223846465527Nonecode25Supplying and fixing PVC / metal conduit accessories Deep type junction box a) 19/20 mm dia 2 mm thickEach49.049.06.0FalseNoneNoneFalseNoneFalse294.00
223846565527Nonecode26Supplying and flush mounting teak wooden box without front plank, made of not less than 12 mm thick wood, after due groove cutting, necessary masonry patch work complete a)12"x12x3" (300x300x76 mm)Each120.0120.06.0FalseNoneNoneFalseNoneFalse720.00
223846665527Nonecode27Point wiring using copper wire with switch Supplying and wiring adopting loop system in existing PVC conduit / casing caping using copper PVC insulated multi strand 2x1 5 sqmm copper wire with a 6 Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shaft be terminated with sufficient boose length in a wood / PVC round block complete for each outlet.a) Shoft point upto 3 Mtr from tapping point to outlet via switchEach285.0285.05.0FalseNoneNoneFalseNoneFalse1425.00
223846765527Nonecode28Point wiring using copper wire with switch Supplying and wiring adopting loop system in existing PVC conduit / casing caping using copper PVC insulated multi strand 2x1 5 sqmm copper wire with a 6 Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shaft be terminated with sufficient boose length in a wood / PVC round block complete for each outlet.b) Medium point upto 3 Mtr from tapping point to outlet via switchEach379.0379.05.0FalseNoneNoneFalseNoneFalse1895.00
223846865527Nonecode29Supplying and fixing of modular switch / socket / stepped electronic fan regulator dimmer / telephone socket etc on existing modular switch plate.Each102.0102.010.0FalseNoneNoneFalseNoneFalse1020.00
223846965527Nonecode30Supplying and fixing 3 mm thick hylum plastic sheet etc complete with necessary nitches and screws etc complete.cm0.410.41552.0FalseNoneNoneFalseNoneFalse226.320
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17057345900000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17057345900000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17057345900000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17057345900000NoneNoneELIGIBILITYDepartment Registration DetailsNone
17057345900000NoneNoneELIGIBILITYTotal value of civl engineering works executed and payments received in the last five years (year-wise)None
17057345900000NoneNoneELIGIBILITYList of existing commitments and ongoing workNone
17057345900000NoneNoneELIGIBILITYList of works for which tenders already submittedNone
17057345900000NoneNoneELIGIBILITYBanker DetailsNone
17057346030000NoneNoneELIGIBILITYThe Employer reserves the right to reject any or all Tenders without assigning any reason.None
17057346160000NoneNoneELIGIBILITYCorrigendum modifications correction, if any, will be published in the website only,None
17057346230000NoneNoneELIGIBILITYDefect liability period will be one yearNone
17057346560000NoneNoneELIGIBILITYTo qualify for award of this contract, each Tenderer in his name should have in the last five years i.e 2018-19 to 2022-23 a. Achieved in at least two financial years a minimum financial turnover in all classes of civil engineering construction works only of Amount Put Tender (Turn over With compulsory UDIN Number)None
17057346640000NoneNoneELIGIBILITYTo qualify for award of this contract, each Tenderer in his name should have in the last five years i.e 2018-19 to 2022-23 b. Satisfactorily completed, as prime contractor, at least one similar work of value not less than 50% of the amount put tender (Workdone with indent No)None
17057346700000NoneNoneELIGIBILITYIf the tenderer has quoted below the schedule-B amount the difference amount should be paid in the form of F.D.R or D.D (As per G.O) in the name of Executive Engineer, PRE Division, Vijayanagara Hosapete from Nationalized Bank only and Upload the scanned copy of the same in e-portal at the time of applying the tender The Same Scanned copy for Different work will be liable for RejectionNone
17057346780000NoneNoneELIGIBILITYAll other conditions and requirements has to be fulfilled as per the standard bid document and attached General conditionsNone
17057346890000NoneNoneELIGIBILITYWork completion period will be 6 monthsNone
preQualCriterionListNone
technicalCriterionListNone
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Valid PWD Registration copyTrueTechnical Bid
Last 5 years Audit Report with UDIN NoTrueTechnical Bid
Similar Nature Work done certificate with eproc Indent NoTrueTechnical Bid
Difference Amount DD or FDR Scanned copyTrueTechnical Bid
Ongoing commitments and other KW DocumentsTrueTechnical Bid
tenderWorkLocationList
tenderSubEstimateNamedistrictNametaluqNameloksabhaContNameassemblyContNamelocationDescriptionlatitudeDegreeslatitudeMinuteslatitudeSecondslongitudeDegreeslongitudeMinuteslongitudeSeconds
BuildingsVijayanagaraHosapeteBellaryHOSPETHosapete TownNoneNoneNoneNoneNoneNone
tenderAddressNone
tenderRecallDTONone