| 2327438 | 68750 | None | 2.5.1 V-I | Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all lead and lifts as per direction Engineering in Charge of the work | Cum | 11099.78 | 11099.78 | 3.27 | False | None | None | False | None | False | 36296.2806 | 0 |
| 2327439 | 68750 | None | 2.5.1 V-I | Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all lead and lifts as per direction Engineering in Charge of the work | Cum | 10450.67 | 10450.67 | 8.0 | False | None | None | False | None | False | 83605.36 | 0 |
| 2327440 | 68750 | None | 2.5.1 V-I | Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all lead and lifts as per direction Engineering in Charge of the work | Cum | 9801.56 | 9801.56 | 15.71 | False | None | None | False | None | False | 153982.5076 | 0 |
| 2327441 | 68750 | None | 2.5.1 V-I | Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all lead and lifts as per direction Engineering in Charge of the work | Cum | 9477.01 | 9477.01 | 0.2 | False | None | None | False | None | False | 1895.402 | 0 |
| 2327442 | 68750 | None | 2.1.4 V-1 | Providing and laying in position plain cement concrete for levellingcourse for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant ISCodes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse
aggregates | Cum | 6074.54 | 6074.54 | 0.4 | False | None | None | False | None | False | 2429.816 | 0 |
| 2327443 | 68750 | None | 6.2 V-I | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. with all lead and lifts as per direction Engineering in Charge of the work with all lead and lifts as per direction Engineering in Charge of the work | Cum | 7097.56 | 7097.56 | 27.58 | False | None | None | False | None | False | 195750.7048 | 0 |
| 2327444 | 68750 | None | 11.32 V-II | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) with all lead and lifts as per direction Engineering in Charge of the work with all lead and lifts as per direction Engineering in Charge of the work | Kg | 97.52 | 97.52 | 2624.0 | False | None | None | False | None | False | 255892.48 | 0 |
| 2327445 | 68750 | None | 12.11 V-II | Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. with all lead and lifts as per direction Engineering in Charge of the work with all lead and lifts as per direction Engineering in Charge of the work | Cum | 95816.58 | 95816.58 | 0.06 | False | None | None | False | None | False | 5748.9948 | 0 |
| 2327446 | 68750 | None | 12.15 V-II | Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures ) | Sqm | 5378.44 | 5378.44 | 2.88 | False | None | None | False | None | False | 15489.9072 | 0 |
| 2327447 | 68750 | None | 11.11.1 V-II | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment) | Kg | 127.2 | 127.2 | 225.0 | False | None | None | False | None | False | 28620.0 | 0 |
| 2327448 | 68750 | None | 11.34B V-II | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. with all lead and lifts as per direction Engineering in Charge of the work | Kg | 166.42 | 166.42 | 1789.2 | False | None | None | False | None | False | 297758.664 | 0 |
| 2327449 | 68750 | None | 8.1.2 V-II | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 209.88 | 209.88 | 106.12 | False | None | None | False | None | False | 22272.4656 | 0 |
| 2327450 | 68750 | None | 8.5.2 V-ll | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 311.64 | 311.64 | 53.83 | False | None | None | False | None | False | 16775.5812 | 0 |
| 2327451 | 68750 | None | 8.3.1V-II | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost
of materials, labour, curing complete as per specifications and as per
directions of Engineer-in-charge. | Sqm | 316.94 | 316.94 | 232.58 | False | None | None | False | None | False | 73713.9052 | 0 |
| 2327452 | 68750 | None | 9.24 V-II | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. with all lead and lifts as per direction Engineering in Charge of the work | Sqm | 3042.2 | 3042.2 | 102.81 | False | None | None | False | None | False | 312768.582 | 0 |
| 2327453 | 68750 | None | 8.25 V-ll | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after
thoroughly brooming the surface to remove all dirt, dust, mortar dropsand foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as
per directions of Engineer-in-charge. | Sqm | 111.3 | 111.3 | 233.45 | False | None | None | False | None | False | 25982.985 | 0 |
| 2327454 | 68750 | None | 8.31 V-II | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. with all lead and lifts as per direction Engineering in Charge of the work | Sqm | 139.92 | 139.92 | 198.64 | False | None | None | False | None | False | 27793.7088 | 0 |
| 2327455 | 68750 | None | 8.51 V-II | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. with all lead and lifts as per direction Engineering in Charge of the work | Sqm | 95.45 | 95.45 | 233.45 | False | None | None | False | None | False | 22282.8025 | 0 |
| 2327456 | 68750 | None | 8.40 V-II | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. with all lead and lifts as per direction Engineering in Charge of the work | Sqm | 103.5 | 103.5 | 25.34 | False | None | None | False | None | False | 2622.69 | 0 |
| 2327457 | 68750 | None | 15.1 V-II | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge | Sqm | 789.7 | 789.7 | 304.7 | False | None | None | False | None | False | 240621.59 | 0 |
| 2327458 | 68750 | None | 1.1.1 PWD ELE V-VI | Supplying heavy gauge PVC conduit pipe 19/20 mm dia 2 mm thick confirming to IS 2509 with suitable size bends, junctionboxes, adhesive paste etc , and fixing using inverted woodplugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. | Rmtr | 68.0 | 68.0 | 100.0 | False | None | None | False | None | False | 6800.0 | 0 |
| 2327459 | 68750 | None | 1.9.1 PWD ELE V-VI | Supplying PVC/GI flexible conduit pipe .... mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely 20 mm with all lead and lifts as per direction Engineering in Charge of the work | Rmtr | 25.0 | 25.0 | 100.0 | False | None | None | False | None | False | 2500.0 | 0 |
| 2327460 | 68750 | None | 2.3.2 PWD ELE V-VI | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 mm2 with all lead and lifts as per direction Engineering in Charge of the work | Rmtr | 26.0 | 26.0 | 50.0 | False | None | None | False | None | False | 1300.0 | 0 |
| 2327461 | 68750 | None | 2.3.3 PWD ELE V-VI | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 mm2 with all lead and lifts as per direction Engineering in Charge of the work | Rmtr | 40.0 | 40.0 | 50.0 | False | None | None | False | None | False | 2000.0 | 0 |
| 2327462 | 68750 | None | 2.3.4 PWD ELE V-VI | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 mm2 with all lead and lifts as per direction Engineering in Charge of the work | Rmtr | 59.0 | 59.0 | 50.0 | False | None | None | False | None | False | 2950.0 | 0 |
| 2327463 | 68750 | None | 1.7.1 PWD ELE V-VI | Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete. upto 50 mm conduit in brick wall with all lead and lifts as per direction Engineering in Charge of the work | Rmtr | 26.0 | 26.0 | 100.0 | False | None | None | False | None | False | 2600.0 | 0 |
| 2327464 | 68750 | None | 13.7.1 PWD ELE V-VI | Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA. On wall/ ceiling / Rafter / Girders with all lead and lifts as per direction Engineering in Charge of the work | No | 119.0 | 119.0 | 5.0 | False | None | None | False | None | False | 595.0 | 0 |
| 2327465 | 68750 | None | 2.2.1PWD ELE V-VI | Supplying and wiring adopting loop system in existing PVCConduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Short point upto 3m from tapping point to out let via switch box | Point | 251.0 | 251.0 | 20.0 | False | None | None | False | None | False | 5020.0 | 0 |
| 2327466 | 68750 | None | 2.2.1PWD ELE V-VI | Supplying and wiring adopting loop system in existing PVCConduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Medium point above 3m upto 6m from tapping point to out let via switch box | Point | 361.0 | 361.0 | 20.0 | False | None | None | False | None | False | 7220.0 | 0 |
| 2327467 | 68750 | None | 2.2.1PWD ELE V-VI | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Long point above 6m upto 10m from tapping point to out let via switch box | Point | 542.0 | 542.0 | 15.0 | False | None | None | False | None | False | 8130.0 | 0 |
| 2327468 | 68750 | None | 3.8 PWD ELE V-VI | Supplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc, and fixing on existing wooden or metal box using N.F. screws. with all lead and lifts as per direction Engineering in Charge of the work | Sq CM | 0.29 | 0.29 | 13500.0 | False | None | None | False | None | False | 3915.0 | 0 |
| 2327469 | 68750 | None | 3.14.1 PWD ELE V-VI | Supplying and fixing/replacing of 6/16/32Amps electrical accessories on existing switch board. 6A SP Switch with all lead and lifts as per direction Engineering in Charge of the work.6A SP Switch | No | 43.0 | 43.0 | 40.0 | False | None | None | False | None | False | 1720.0 | 0 |
| 2327470 | 68750 | None | 3.14.3 PWD ELE V-VI | Supplying and fixing/replacing of 6/16/32Amps electrical accessories on existing switch board. 6A Three Way 5 Pin Socket with all lead and lifts as per direction Engineering in Charge of the work. 6A Three Way 5 Pin Socket | No | 65.0 | 65.0 | 18.0 | False | None | None | False | None | False | 1170.0 | 0 |
| 2327471 | 68750 | None | 6.3.2 PWD ELE V-VI | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. 56" Sweep (1400 mm) Regular model with all lead and lifts as per direction Engineering in Charge of the work | No | 2170.0 | 2170.0 | 3.0 | False | None | None | False | None | False | 6510.0 | 0 |
| 2327472 | 68750 | None | 5.18.1 PWD ELE V-VI | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. 4 Way SP & N with all lead and lifts as per direction Engineering in Charge of the work | No | 1104.0 | 1104.0 | 5.0 | False | None | None | False | None | False | 5520.0 | 0 |
| 2327473 | 68750 | None | 13.34A V-II | Providing and placing in Rectangular high density polyethylene water storage loft tank with cover conformin to IS:12701 colour of opaque white or as approved by engineer in charge the rate includings making necessary holes for inlet outlet & over flow pipes the base support i/c fittings & fixtures for tank shall be paid separately with all lead and lifts as per direction Engineering in Charge of the work | Ltr | 8.93 | 8.93 | 1000.0 | False | None | None | False | None | False | 8930.0 | 0 |
| 2327474 | 68750 | None | 13.32.3 V-II | Providing and fiing chlorinated polyvinyl chloride (CPVC) pipes having thrermal stability for hot and cold water supply including all CPVC plain & Brass threaded fitting, i/c fixing the pipe with clamps at 1.00 m spacing this inluded jointing of pipes & jittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing testing of joints complete a per derection of engineer in charge. concealed work including cutting chases and making good the walls etc. 25mm nominal dia pipes with all lead and lifts as per direction Engineering in Charge of the work | Rmtr | 499.8 | 499.8 | 40.0 | False | None | None | False | None | False | 19992.0 | 0 |
| 2327475 | 68750 | None | 14.3 V-V | Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete 110mm(weight of pipe -1.894 kg) with all lead and lifts as per direction Engineering in Charge of the work | Rmtr | 508.2 | 508.2 | 40.0 | False | None | None | False | None | False | 20328.0 | 0 |