| 2340798 | 69265 | None | 19.3 V-II | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material to the appropriate disposal area With all lead and lifts as per the direction of engineer incharge | Cum | 2572.77 | 2572.77 | 2.672 | False | None | None | False | None | False | 6874.44144 | 0 |
| 2340799 | 69265 | None | 19.7.3 V-II | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area With all lead and lifts as per the direction of engineer incharge | Cum | 1091.25 | 1091.25 | 6.91 | False | None | None | False | None | False | 7540.5375 | 0 |
| 2340800 | 69265 | None | 2.5.1 V-I | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates With all lead and lifts as per the direction of engineer incharge | Cum | 11904.17 | 11904.17 | 10.8 | False | None | None | False | None | False | 128565.036 | 0 |
| 2340801 | 69265 | None | 2.5.1 V-I | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates With all lead and lifts as per the direction of engineer incharge | Cum | 11208.02 | 11208.02 | 3.84 | False | None | None | False | None | False | 43038.7968 | 0 |
| 2340802 | 69265 | None | 2.5.1 V-I | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates With all lead and lifts as per the direction of engineer incharge | Cum | 10163.79 | 10163.79 | 0.81 | False | None | None | False | None | False | 8232.6699 | 0 |
| 2340803 | 69265 | None | 2.5.1 V-I | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates With all lead and lifts as per the direction of engineer incharge | Cum | 11208.02 | 11208.02 | 14.74 | False | None | None | False | None | False | 165206.2148 | 0 |
| 2340804 | 69265 | None | 2.5.1 V-I | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates With all lead and lifts as per the direction of engineer incharge | Cum | 10511.87 | 10511.87 | 57.76 | False | None | None | False | None | False | 607165.6112 | 0 |
| 2340805 | 69265 | None | 6.32 V-II | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.With all lead and lifts as per the direction of engineer incharge | Sqm | 1389.26 | 1389.26 | 417.18 | False | None | None | False | None | False | 579571.4868 | 0 |
| 2340806 | 69265 | None | 8.2.1 V-II | Providing 15 mm thick cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 312.85 | 312.85 | 543.82 | False | None | None | False | None | False | 170134.087 | 0 |
| 2340807 | 69265 | None | 8.3.1 V-II | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 375.42 | 375.42 | 389.52 | False | None | None | False | None | False | 146233.5984 | 0 |
| 2340808 | 69265 | None | 8.51 V-II | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 106.05 | 106.05 | 931.44 | False | None | None | False | None | False | 98779.212 | 0 |
| 2340809 | 69265 | None | 8.33.1 V-II | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 g/l, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. Two coats on new work to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 167.56 | 167.56 | 931.44 | False | None | None | False | None | False | 156072.0864 | 0 |
| 2340810 | 69265 | None | 8.30 V-II | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 184.53 | 184.53 | 389.52 | False | None | None | False | None | False | 71878.1256 | 0 |
| 2340811 | 69265 | None | 9.22.2 V-II | Providing and laying Vitrified tiles with thickness 9-10 mm in differentsizes with water absorption less than 0.08 % and conforming to I.S. 15622,of approved make, in all colours & shade, over 12 mm thick bed of cementmortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry@ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete complete Size of Tile 600x600 mm | Sqm | 1406.22 | 1406.22 | 370.36 | False | None | None | False | None | False | 520807.6392 | 0 |
| 2340812 | 69265 | None | 2.11a V-II | Steel Fabrication Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification) | Tonne | 94869.15 | 94869.15 | 7.99 | False | None | None | False | None | False | 758004.5085 | 0 |
| 2340813 | 69265 | None | 11.15.2 V-II | Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer: Fixing with carbon steel galvanised dash fastener of required dia and size including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 125.14 | 125.14 | 504.0 | False | None | None | False | None | False | 63070.56 | 0 |
| 2340814 | 69265 | None | 11.30.1 V-II | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-
Charge | Sqm | 967.18 | 967.18 | 25.2 | False | None | None | False | None | False | 24372.936 | 0 |
| 2340815 | 69265 | None | 11.34a V-II | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. | Kg | 178.16 | 178.16 | 1691.34 | False | None | None | False | None | False | 301329.1344 | 0 |
| 2340816 | 69265 | None | 2.1.4 V-I | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granit / trap / basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6593.13 | 6593.13 | 2.95 | False | None | None | False | None | False | 19449.7335 | 0 |
| 2340817 | 69265 | None | 11.5.1 V-II | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 4748.92 | 4748.92 | 17.64 | False | None | None | False | None | False | 83770.9488 | 0 |
| 2340818 | 69265 | None | 8.30.30 V-II | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 147.41 | 147.41 | 116.72 | False | None | None | False | None | False | 17205.6952 | 0 |
| 2340819 | 69265 | None | 8.70 V-II | Painting (one coats) with black Japan paint of approved brand and manufactureto give an even shade. including preparing the surface after thoroughlycleaning the surface to remove all dirt, dust and foreign matter , costof materials, labour complete as per specifications and as per directionsof Engineer-in-charge . | Sqm | 72.11 | 72.11 | 24.0 | False | None | None | False | None | False | 1730.64 | 0 |
| 2340820 | 69265 | None | 10.1.6 V-v | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into
trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 90mm dia., 6 kg/sqcm & class 3 | MT | 296.94 | 296.94 | 90.0 | False | None | None | False | None | False | 26724.6 | 0 |
| 2340821 | 69265 | None | 1.3.2 PWD ELE V-VI | Supplying heavy gauge PVC Conduit piipe.... dia....mm thick with suitable size bends, metal junction boxes adhesive paste etc. by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.19mm dia 2mm thick | Rmtr | 69.0 | 69.0 | 200.0 | False | None | None | False | None | False | 13800.0 | 0 |
| 2340822 | 69265 | None | 1.3.2 PWD ELE V-VI | Supplying heavy gauge PVC Conduit piipe.... dia....mm thick with suitable size bends, metal junction boxes adhesive paste etc. by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary 25mm dia 2mm thick | Rmtr | 81.0 | 81.0 | 120.0 | False | None | None | False | None | False | 9720.0 | 0 |
| 2340823 | 69265 | None | 1.7.1 PWD ELE V-VI | Groove cutting Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of conduit/GI pipe and plastering, finishing upto wall surface complete.Upto 50mm conduit | Rmtr | 29.0 | 29.0 | 120.0 | False | None | None | False | None | False | 3480.0 | 0 |
| 2340824 | 69265 | None | 1.4 PWD ELE V-VI | Supplying and fixing sheet metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc.135*75*65 | Each | 139.0 | 139.0 | 8.0 | False | None | None | False | None | False | 1112.0 | 0 |
| 2340825 | 69265 | None | 1.4 PWD ELE V-VI | Supplying and fixing sheet metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc.200*200*65 | Each | 348.0 | 348.0 | 8.0 | False | None | None | False | None | False | 2784.0 | 0 |
| 2340826 | 69265 | None | 1.5 PWD ELE V-VI | Supplying and fixing PVC/metal conduit Deep junction box 19/20mm deep junction box | Each | 49.0 | 49.0 | 8.0 | False | None | None | False | None | False | 392.0 | 0 |
| 2340827 | 69265 | None | 1.5 PWD ELE V-VI | Supplying and fixing PVC/metal conduit Deep junction box 25mm deep junction box | Each | 56.0 | 56.0 | 8.0 | False | None | None | False | None | False | 448.0 | 0 |
| 2340828 | 69265 | None | 1.10 PWD ELE V-VI | Supplying and fixing "S' Hook made out of 14mm dia MS Rod | Nos | 36.0 | 36.0 | 32.0 | False | None | None | False | None | False | 1152.0 | 0 |
| 2340829 | 69265 | None | 2.1.1 PWD ELE V-VI | Point wiring using Copper wire with switch : Supplying and wiring adopting loop system in existing PVC conduit /casing capping using 2x1.5sqmm (Phase and neutral) and 1x1.00sqmm (Earth wire0 FRLS multistrand PVC insulated copper wire (confirming to IS-694 : and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet (a) Short point upto 3mtr from tapping point to outlet via switch | Point | 285.0 | 285.0 | 80.0 | False | None | None | False | None | False | 22800.0 | 0 |
| 2340830 | 69265 | None | 3.5.1 PWD ELE V-VI | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 1-2 Module | Each | 137.0 | 137.0 | 4.0 | False | None | None | False | None | False | 548.0 | 0 |
| 2340831 | 69265 | None | 3.5.1 PWD ELE V-VI | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 6 Module | Each | 234.0 | 234.0 | 8.0 | False | None | None | False | None | False | 1872.0 | 0 |
| 2340832 | 69265 | None | 3.4 PWD ELE V-VI | Supplying and flush mounting powder coated/galvnized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/CC wall 1-2 Way | Each | 138.0 | 138.0 | 4.0 | False | None | None | False | None | False | 552.0 | 0 |
| 2340833 | 69265 | None | 3.4 PWD ELE V-VI | Supplying and flush mounting powder coated/galvnized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/CC wall 6 Way | Each | 220.0 | 220.0 | 8.0 | False | None | None | False | None | False | 1760.0 | 0 |
| 2340834 | 69265 | None | 3.6.1 PWD ELE V-VI | Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6Amps one way | Each | 102.0 | 102.0 | 8.0 | False | None | None | False | None | False | 816.0 | 0 |
| 2340835 | 69265 | None | 3.6.1 PWD ELE V-VI | Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6Amps Two way | Each | 166.0 | 166.0 | 8.0 | False | None | None | False | None | False | 1328.0 | 0 |
| 2340836 | 69265 | None | 3.6.1 PWD ELE V-VI | Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293 Stepped Fan | Each | 357.0 | 357.0 | 14.0 | False | None | None | False | None | False | 4998.0 | 0 |
| 2340837 | 69265 | None | 3.6.1 PWD ELE V-VI | Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293 TV/Telephone | Each | 156.0 | 156.0 | 3.0 | False | None | None | False | None | False | 468.0 | 0 |
| 2340838 | 69265 | None | 3.7 PWD ELE V-VI | Supplying and fixing 32Amps security and energy saving DP switch with key tag suitable to operate on 230 volts. 50Hz AC supply and completely wired on existing box | Each | 646.0 | 646.0 | 1.0 | False | None | None | False | None | False | 646.0 | 0 |
| 2340839 | 69265 | None | 3.8 PWD ELE V-VI | Supplying 4mm thick plastic sheet with necessary nitches for fixing switches. regulators etc., and fixing on existing wooden or metal box using NF screws. | Each | 0.41 | 0.41 | 10.0 | False | None | None | False | None | False | 4.1 | 0 |
| 2340840 | 69265 | None | 3.12 PWD ELE V-VI | Supplying way plastic gang box and fixing using necessary wooden/rawl/phill plugs and screws 1 way gang box | Each | 23.0 | 23.0 | 4.0 | False | None | None | False | None | False | 92.0 | 0 |
| 2340841 | 69265 | None | 3.12 PWD ELE V-VI | Supplying way plastic gang box and fixing using necessary wooden/rawl/phill plugs and screws 2 to 4 way gang box | Each | 32.0 | 32.0 | 8.0 | False | None | None | False | None | False | 256.0 | 0 |
| 2340842 | 69265 | None | 3.14 PWD ELE V-VI | Supplying and fixing /replacing of 6/16/32Amps electrical accessories on existing switch board. 6 Amps | Each | 70.0 | 70.0 | 12.0 | False | None | None | False | None | False | 840.0 | 0 |
| 2340843 | 69265 | None | 5.4.1 PWD ELE V-VI | Fixing a Shunt capacitor of ….KVAR capacity with necessary clamps, bolts and nuts on existing wooden or metal board including banking of more than one capacitor | Each | 154.0 | 154.0 | 4.0 | False | None | None | False | None | False | 616.0 | 0 |
| 2340844 | 69265 | None | 2.3.1 PWD ELE V-VI | Wiring for lighting /power circuit using one of PVC insulated 1100V Grade ,muftis and copper conductor single core cable in open or concealed system of wiring. Using class ‘A’ approved materialals. 1Sqmm 2.5Sqmm | Mtr | 42.0 | 42.0 | 300.0 | False | None | None | False | None | False | 12600.0 | 0 |
| 2340845 | 69265 | None | 5.6.6 PWD ELE V-VI | Supplying and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws. 20"x20"x2.5" | Each | 326.13 | 326.13 | 12.0 | False | None | None | False | None | False | 3913.56 | 0 |
| 2340846 | 69265 | None | 5.7.1 PWD ELE V-VI | Supplying and fixing of porcelain fuse channel with cut out on existing wooden/panel using necessary nuts.bolts and washers 16Amps | Each | 157.0 | 157.0 | 12.0 | False | None | None | False | None | False | 1884.0 | 0 |
| 2340847 | 69265 | None | 5.19.1 PWD ELE V-VI | Supplying and fixing regular MCB distribution boards on wall/wood board/flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCBs single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure 4 way SP and N | Each | 1241.0 | 1241.0 | 4.0 | False | None | None | False | None | False | 4964.0 | 0 |
| 2340848 | 69265 | None | 6.3.1 PWD ELE V-VI | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. single phase AC supply conforming to ISS-374-1979 and with double ball bearing system48" Sweep (1200 mm) Regular model (1200mm) Regular Model | Each | 2984.0 | 2984.0 | 12.0 | False | None | None | False | None | False | 35808.0 | 0 |
| 2340849 | 69265 | None | 11.3.1 PWD ELE V-VI | Supplying of LED light fighting 1x2'-9/10w.feet-PVC batten with integrated LED tube ..... W with high quality diffuser with life of 25000 burning hours and 70% lumen maintenance with CRI 80. Power input 220-240v @ 50/60Hz and power factor 0.9 along with CE approved 2 years warranty against any maufacturing defect working under standard electrical condition. | Each | 551.0 | 551.0 | 20.0 | False | None | None | False | None | False | 11020.0 | 0 |