2337643 | 69096 | None | VJP01 | Earth work in surface excavation for stripping, seating of bund, Road way, by manual means for lowering & leveling the ground for all works other than foundation & depth in all kinds of soil not exceeding 300mm as per drawing and technical specifications, including setting out, shor ing, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. In all kinds of soil upto 300 mm depth with all lead and lift as per the direction of engineer incharge of work | Sqm | 73.5 | 73.5 | 70.4 | False | None | None | False | None | False | 5174.4 | 0 |
2337644 | 69096 | None | VJP02 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m with all lead and lift as per the direction of engineer incharge of work | Cum | 76.65 | 76.65 | 53.15 | False | None | None | False | None | False | 4073.9475 | 0 |
2337645 | 69096 | None | VJP03 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates with all lead and lift as per the direction of engineer incharge of work | Cum | 5466.3 | 5466.3 | 12.41 | False | None | None | False | None | False | 67836.783 | 0 |
2337646 | 69096 | None | VJP04 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. For Footings, and Pedestal with all lead and lift as per the direction of engineer incharge of work | Cum | 6739.36 | 6739.36 | 10.79 | False | None | None | False | None | False | 72717.6944 | 0 |
2337647 | 69096 | None | VJP05 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. For Columns upto GL with all lead and lift as per the direction of engineer incharge of work | Cum | 10608.26 | 10608.26 | 0.39 | False | None | None | False | None | False | 4137.2214 | 0 |
2337648 | 69096 | None | VJP06 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. For Columns upto Plinth with all lead and lift as per the direction of engineer incharge of work | Cum | 10652.88 | 10652.88 | 0.52 | False | None | None | False | None | False | 5539.4976 | 0 |
2337649 | 69096 | None | VJP07 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. For Plinth Beam with all lead and lift as per the direction of engineer incharge of work | Cum | 9399.6 | 9399.6 | 3.75 | False | None | None | False | None | False | 35248.5 | 0 |
2337650 | 69096 | None | VJP08 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) with all lead and lift as per the direction of engineer incharge of work | Cum | 4987.5 | 4987.5 | 26.99 | False | None | None | False | None | False | 134612.625 | 0 |
2337651 | 69096 | None | VJP09 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m with all lead and lift as per the direction of engineer incharge of work | Cum | 214.2 | 214.2 | 30.92 | False | None | None | False | None | False | 6623.064 | 0 |
2337652 | 69096 | None | VJP10 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. with all lead and lift as per the direction of engineer incharge of work | Cum | 7024.5 | 7024.5 | 21.14 | False | None | None | False | None | False | 148497.93 | 0 |
2337653 | 69096 | None | VJP11 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technicalspecifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately). M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. For Columns Floor level to Roof level with all lead and lift as per the direction of engineer incharge of work | Cum | 11034.87 | 11034.87 | 2.89 | False | None | None | False | None | False | 31890.7743 | 0 |
2337654 | 69096 | None | VJP12 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technicalspecifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately). M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. For Lintel and Roof beam with all lead and lift as per the direction of engineer incharge of work | Cum | 10385.76 | 10385.76 | 4.81 | False | None | None | False | None | False | 49955.5056 | 0 |
2337655 | 69096 | None | VJP13 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technicalspecifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately). M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. For Roof slab with all lead and lift as per the direction of engineer incharge of work | Cum | 9736.65 | 9736.65 | 11.7 | False | None | None | False | None | False | 113918.805 | 0 |
2337656 | 69096 | None | VJP14 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technicalspecifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately). M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. For Chejja and Rack with all lead and lift as per the direction of engineer incharge of work | Cum | 9412.1 | 9412.1 | 0.83 | False | None | None | False | None | False | 7812.043 | 0 |
2337657 | 69096 | None | VJP15 | Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge with all lead and lift as per the direction of engineer incharge of work | Sqm | 289.8 | 289.8 | 326.95 | False | None | None | False | None | False | 94750.11 | 0 |
2337658 | 69096 | None | VJP16 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. with all lead and lift as per the direction of engineer incharge of work | Sqm | 207.9 | 207.9 | 44.58 | False | None | None | False | None | False | 9268.182 | 0 |
2337659 | 69096 | None | VJP17 | Providig lath plaster with cement mortor 1:3, 5cms thick with 6mm dia mild steel bars at 20 cms. C to c both horizonrtally and vertically fixed with chicken mesh for drop chajja, facia, backing to cup boards including cost of all materials, labour, providing and removing formwork usage charges, curing complete as per specifications. with all lead and lift as per the direction of engineer incharge of work | Sqm | 1233.75 | 1233.75 | 7.2 | False | None | None | False | None | False | 8883.0 | 0 |
2337660 | 69096 | None | VJP18 | Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications with all lead and lift as per the direction of engineer incharge of work | Sqm | 1251.6 | 1251.6 | 50.99 | False | None | None | False | None | False | 63819.084 | 0 |
2337661 | 69096 | None | VJP19 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and with all lead and lift as per the direction of engineer incharge of work | Sqm | 110.25 | 110.25 | 208.4 | False | None | None | False | None | False | 22976.1 | 0 |
2337662 | 69096 | None | VJP20 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and with all lead and lift as per the direction of engineer incharge of work | Sqm | 69.3 | 69.3 | 170.32 | False | None | None | False | None | False | 11803.176 | 0 |
2337663 | 69096 | None | VJP21 | Painting with synthetic enamel paint of approved brand and manu facture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and with all lead and lift as per the direction of engineer incharge of work | Sqm | 94.5 | 94.5 | 98.24 | False | None | None | False | None | False | 9283.68 | 0 |
2337664 | 69096 | None | VJP22 | Providing Thermo-Mechanically Treated bars of grade Fe-550 Steel reinforcement for R.C.C. work including straightening, cut ting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) with all lead and lift as per the direction of engineer incharge of work | Kg | 96.6 | 96.6 | 3210.45 | False | None | None | False | None | False | 310129.47 | 0 |
2337665 | 69096 | None | VJP23 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications andwith all lead and lift as per the direction of engineer incharge of work | Sqm | 2635.5 | 2635.5 | 43.04 | False | None | None | False | None | False | 113431.92 | 0 |
2337666 | 69096 | None | VJP24 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding with all lead and lift as per the direction of engineer incharge of work | Kg | 152.25 | 152.25 | 34.02 | False | None | None | False | None | False | 5179.545 | 0 |
2337667 | 69096 | None | VJP25 | Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete including cost of materials, labour, usage charges of machinery complete as per specifications and with all lead and lift as per the direction of engineer incharge of work | Sqm | 3655.05 | 3655.05 | 1.62 | False | None | None | False | None | False | 5921.181 | 0 |
2337668 | 69096 | None | VJP26 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.
Short point upto 3 mts from tapping point to out let via switch box as per the direction of engineer incharge of work | Point | 251.0 | 251.0 | 20.0 | False | None | None | False | None | False | 5020.0 | 0 |
2337669 | 69096 | None | VJP27 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.
Medium point above 3 mts upto 6mts from tapping point to outlet via switch box as per the direction of engineer incharge of work | Point | 361.0 | 361.0 | 8.0 | False | None | None | False | None | False | 2888.0 | 0 |
2337670 | 69096 | None | VJP28 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall (6 Way) as per the direction of engineer incharge of work | Each | 212.0 | 212.0 | 4.0 | False | None | None | False | None | False | 848.0 | 0 |
2337671 | 69096 | None | VJP29 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall (8 Way) as per the direction of engineer incharge of work | Each | 250.0 | 250.0 | 4.0 | False | None | None | False | None | False | 1000.0 | 0 |
2337672 | 69096 | None | VJP30 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 6 Module as per the direction of engineer incharge of work | Each | 244.0 | 244.0 | 4.0 | False | None | None | False | None | False | 976.0 | 0 |
2337673 | 69096 | None | VJP31 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 8 Module as per the direction of engineer incharge of work | Each | 302.0 | 302.0 | 4.0 | False | None | None | False | None | False | 1208.0 | 0 |
2337674 | 69096 | None | VJP32 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 amps one way switch as per the direction of engineer incharge of work | Each | 88.0 | 88.0 | 24.0 | False | None | None | False | None | False | 2112.0 | 0 |
2337675 | 69096 | None | VJP33 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 amps two way switch as per the direction of engineer incharge of work | Each | 152.0 | 152.0 | 4.0 | False | None | None | False | None | False | 608.0 | 0 |
2337676 | 69096 | None | VJP34 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 Amps 3 way sockets as per the direction of engineer incharge of work | Each | 162.0 | 162.0 | 4.0 | False | None | None | False | None | False | 648.0 | 0 |
2337677 | 69096 | None | VJP35 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 stepped fan Regulator's as per the direction of engineer incharge of work | Each | 313.0 | 313.0 | 4.0 | False | None | None | False | None | False | 1252.0 | 0 |
2337678 | 69096 | None | VJP36 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6/16 Amps universal sockets as per the direction of engineer incharge of work | Each | 249.0 | 249.0 | 4.0 | False | None | None | False | None | False | 996.0 | 0 |
2337679 | 69096 | None | VJP37 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 16A one way switch as per the direction of engineer incharge of work | Each | 249.0 | 249.0 | 4.0 | False | None | None | False | None | False | 996.0 | 0 |
2337680 | 69096 | None | VJP38 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 Extra length of GI pipe of class B 19mm dia for down rod as per the direction of engineer incharge of work | Each | 173.0 | 173.0 | 4.0 | False | None | None | False | None | False | 692.0 | 0 |
2337681 | 69096 | None | VJP39 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 Supply and fixing one metal Fan box with round hook as per the direction of engineer incharge of work | Each | 163.0 | 163.0 | 4.0 | False | None | None | False | None | False | 652.0 | 0 |
2337682 | 69096 | None | VJP40 | Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 20mm dia pipe as per the direction of engineer incharge of work | Mtr | 61.0 | 61.0 | 80.0 | False | None | None | False | None | False | 4880.0 | 0 |
2337683 | 69096 | None | VJP41 | Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 25mm dia pipe as per the direction of engineer incharge of work | Mtr | 70.0 | 70.0 | 40.0 | False | None | None | False | None | False | 2800.0 | 0 |
2337684 | 69096 | None | VJP42 | Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary Groove Cutting in Wall 20mm dia as per the direction of engineer incharge of work | Mtr | 75.0 | 75.0 | 80.0 | False | None | None | False | None | False | 6000.0 | 0 |
2337685 | 69096 | None | VJP43 | Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary Groove Cutting in Wall 25mm dia as per the direction of engineer incharge of work | Mtr | 80.0 | 80.0 | 40.0 | False | None | None | False | None | False | 3200.0 | 0 |
2337686 | 69096 | None | VJP44 | Supplying and fixing PVC/metal conduit deep junction box .
19/20mm deep junction box as per the direction of engineer incharge of work | Each | 49.0 | 49.0 | 20.0 | False | None | None | False | None | False | 980.0 | 0 |
2337687 | 69096 | None | VJP45 | Supplying and fixing PVC/metal conduit deep junction box .
25mm deep junction box as per the direction of engineer incharge of work | Each | 51.0 | 51.0 | 10.0 | False | None | None | False | None | False | 510.0 | 0 |
2337688 | 69096 | None | VJP46 | FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 1.5 Sq.mm as per the direction of engineer incharge of work | Mtr | 26.0 | 26.0 | 90.0 | False | None | None | False | None | False | 2340.0 | 0 |
2337689 | 69096 | None | VJP47 | FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 2.5 Sq.mm as per the direction of engineer incharge of work | Mtr | 40.0 | 40.0 | 60.0 | False | None | None | False | None | False | 2400.0 | 0 |
2337690 | 69096 | None | VJP48 | FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 4 Sq.mm as per the direction of engineer incharge of work | Mtr | 59.0 | 59.0 | 30.0 | False | None | None | False | None | False | 1770.0 | 0 |
2337691 | 69096 | None | VJP49 | Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 20A single phase Class-1 Accuracy with Temper Proof Energy Meter. as per the direction of engineer incharge of work | Each | 1242.0 | 1242.0 | 4.0 | False | None | None | False | None | False | 4968.0 | 0 |
2337692 | 69096 | None | VJP50 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden /panel using necessary nuts, bolts and washers. 32Amps as per the direction of engineer incharge of work | Each | 200.0 | 200.0 | 4.0 | False | None | None | False | None | False | 800.0 | 0 |
2337693 | 69096 | None | VJP51 | Supplying and fixing 6-32A DP MCB miniature circuit breaker 10 Ka,with C curve, on the existing MCB distribution board using necessary fixing materials and wiring complete as required as per the direction of engineer incharge of work | Each | 1103.0 | 1103.0 | 4.0 | False | None | None | False | None | False | 4412.0 | 0 |
2337694 | 69096 | None | VJP52 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 12 Way SP & N as per the direction of engineer incharge of work | Each | 1591.0 | 1591.0 | 4.0 | False | None | None | False | None | False | 6364.0 | 0 |
2337695 | 69096 | None | VJP53 | Supplying and fixing 6 to 32 Amps SP miniature circuit breaker 10 Ka,with C curve, on the existing MCB distribution board using necessary fixing materials and wiring complete as required as per the direction of engineer incharge of work | Each | 523.0 | 523.0 | 4.0 | False | None | None | False | None | False | 2092.0 | 0 |
2337696 | 69096 | None | VJP54 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 hms/Kms (Max) as per IS-3975 (3.5 core 35sqmm ) as per the direction of engineer incharge of work | Mtr | 225.0 | 225.0 | 15.0 | False | None | None | False | None | False | 3375.0 | 0 |
2337697 | 69096 | None | VJP55 | Labour charges for laying of 25Sqmm to 75 Sqmm 1.1 KV class UG cable when supplied agency in existing trench / on wall as required as per the direction of engineer incharge of work | Mtr | 15.5 | 15.5 | 15.0 | False | None | None | False | None | False | 232.5 | 0 |
2337698 | 69096 | None | VJP56 | Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only). 25mm as per the direction of engineer incharge of work | Each | 84.0 | 84.0 | 4.0 | False | None | None | False | None | False | 336.0 | 0 |
2337699 | 69096 | None | VJP57 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. (1.5 sq.mm) as per the direction of engineer incharge of work | Each | 3.0 | 3.0 | 20.0 | False | None | None | False | None | False | 60.0 | 0 |
2337700 | 69096 | None | VJP58 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. (2.5 sq.mm) as per the direction of engineer incharge of work | Each | 4.0 | 4.0 | 30.0 | False | None | None | False | None | False | 120.0 | 0 |
2337701 | 69096 | None | VJP59 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. (4 sq.mm) as per the direction of engineer incharge of work | Each | 7.0 | 7.0 | 10.0 | False | None | None | False | None | False | 70.0 | 0 |
2337702 | 69096 | None | VJP60 | Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm alround with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts. as per the direction of engineer incharge of work | Each | 4150.0 | 4150.0 | 1.0 | False | None | None | False | None | False | 4150.0 | 0 |
2337703 | 69096 | None | VJP61 | Supplying and running of GI Strip of size 25 x 6mm for grounding connections using necessary fixing materials as required as per the direction of engineer incharge of work | Rmtr | 115.0 | 115.0 | 1.0 | False | None | None | False | None | False | 115.0 | 0 |
2337704 | 69096 | None | VJP62 | Supplying of ......feet - PVC Batten with integrated LED tube.....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. (LED light fighting 4'-20/22watts) as per the direction of engineer incharge of work | Each | 740.0 | 740.0 | 10.0 | False | None | None | False | None | False | 7400.0 | 0 |
2337705 | 69096 | None | VJP63 | Supplying of ......feet - PVC Batten with integrated LED tube.....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. (LED light fighting1X 2'-10watts) as per the direction of engineer incharge of work | Each | 496.0 | 496.0 | 4.0 | False | None | None | False | None | False | 1984.0 | 0 |
2337706 | 69096 | None | VJP64 | Supplying capacitor type 48" sweep(1200mm) ceiling fan complete with down rod blades , shackle canopies etc suitable for operation on 230V 50 cycles single phase AC supply conforming to ISS - 374 - 1979 and with double ball bearing system [Khaitan, Crompton greaves, Usha] as per the direction of engineer incharge of work | Each | 2085.0 | 2085.0 | 4.0 | False | None | None | False | None | False | 8340.0 | 0 |
2337707 | 69096 | None | VJP65 | Fixing all types and all capacities fluorescent / false ceiling /spot light / CFL / LED fitting indoors on the wall / ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires . Required nos of round blocks and clamps as per the direction of engineer incharge of work | Each | 119.0 | 119.0 | 4.0 | False | None | None | False | None | False | 476.0 | 0 |
2337708 | 69096 | None | VJP66 | Fixing of Wall/ ceiling fan of all capacities and all types to the existing hook together with supplying and fixing a 5 A ceiling rose , necessary length of 23/0.0076 inch PVC insulated twin twisted copper wire and wiring complete as per the direction of engineer incharge of work | Each | 162.0 | 162.0 | 4.0 | False | None | None | False | None | False | 648.0 | 0 |
2337709 | 69096 | None | VJP67 | Supplying, and fixing of hot dip Galvanized M.S.Bracket suitable for out door liminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete. (Single Arm Bracket with 1000mm Standard 40/50MM dia) as per the direction of engineer incharge of work | Each | 1544.0 | 1544.0 | 4.0 | False | None | None | False | None | False | 6176.0 | 0 |