| 1706540039000 | 1 | None | None | Buildings | CONSTRUCTION OF URINALS A BESIDE APMC NEAR VALMIKI CIRCLE 01 BLOCK WITH 03 SEATS B NEAR PAMPA COMPLEX 02 BLOCKS WITH 03 SEATS GENTS AND 03 SEATS LADIES C NEAR IB INFRONT OF IRRIGATION DEPARTMENT 02 BLOCKS WITH 03 SEATS GENTS AND 03 SEATS LADIES | 403953.07 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 2331299 | 68928 | None | ITEM01 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils Depth upto 3m. PWD CSR Vol-1 2023-24 P.No.8, I.No.1.14.1 | Cum | 107.1 | 107.1 | 10.34 | False | None | None | False | None | False | 1107.414 | 0 | | 2331300 | 68928 | None | ITEM02 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates PWD CSR Vol-1 2023-24 P.No.15, I.No.2.1.4 | Cum | 6527.85 | 6527.85 | 2.507 | False | None | None | False | None | False | 16365.31995 | 0 | | 2331301 | 68928 | None | ITEM03 | Providing Random rubble masonry with hard stone in foundation and
plinth including levelling up with cement concrete 1:6:12 (1 cement : 6
coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1 cement : 6 coarse sand) PWD CSR Vol-1 2023-24 P.No.09, I.No.5.1.1 | Cum | 5891.55 | 5891.55 | 10.3355 | False | None | None | False | None | False | 60892.115025 | 0 | | 2331302 | 68928 | None | ITEM04 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. PWD CSR Vol-1 2023-24 P.No.17, I.No.6.33 | Sqm | 1292.55 | 1292.55 | 72.287 | False | None | None | False | None | False | 93434.56185 | 0 | | 2331303 | 68928 | None | ITEM05 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.. PWD CSR Vol-II 2023-24 P.No.14, I.No.6.15 | Sqm | 1084.65 | 1084.65 | 15.375 | False | None | None | False | None | False | 16676.49375 | 0 | | 2331304 | 68928 | None | ITEM06 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. PWD CSR Vol-1 2023-24 P.No.07, I.No.1.9 | Cum | 279.3 | 279.3 | 2.225 | False | None | None | False | None | False | 621.4425 | 0 | | 2331305 | 68928 | None | ITEM07 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates PWD CSR Vol-1 2023-24 P.No.16, I.No.2.3.1 | Cum | 6639.15 | 6639.15 | 1.6686 | False | None | None | False | None | False | 11078.08569 | 0 | | 2331306 | 68928 | None | ITEM08 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. PWD CSR Vol-II 2023-24 P.No.41, I.No.8.2.2 | Sqm | 292.95 | 292.95 | 160.104 | False | None | None | False | None | False | 46902.4668 | 0 | | 2331307 | 68928 | None | ITEM09 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. PWD CSR Vol-1 2023-24 P.No.45, I.No.8.28 | Sqm | 93.45 | 93.45 | 160.103 | False | None | None | False | None | False | 14961.62535 | 0 | | 2331308 | 68928 | None | ITEM10 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. PWD CSR Vol-II 2023-24 P.No.104, I.No.12.54 | m | 333.9 | 333.9 | 12.0 | False | None | None | False | None | False | 4006.8 | 0 | | 2331309 | 68928 | None | ITEM11 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters with one side prelam made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. PWD CSR Vol-II 2023-24 P.No.104, I.No.12.55.2 | Sqm | 2146.2 | 2146.2 | 3.6 | False | None | None | False | None | False | 7726.32 | 0 | | 2331310 | 68928 | None | ITEM12 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).
Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. PWD CSR Vol-II 2023-24 P.No.79, I.No.11.11.1 | Kg | 155.4 | 155.4 | 85.05 | False | None | None | False | None | False | 13216.77 | 0 | | 2331311 | 68928 | None | ITEM13 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @ 0.80 L/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. PWD CSR Vol-II 2023-24 P.No.47, I.No.8.33.3 | Sqm | 145.95 | 145.95 | 20.07 | False | None | None | False | None | False | 2929.2165 | 0 | | 2331312 | 68928 | None | ITEM14 | Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. PWD CSR Vol-II 2023-24 P.No.70, I.No.10.8 | Sqm | 2928.45 | 2928.45 | 3.75 | False | None | None | False | None | False | 10981.6875 | 0 | | 2331313 | 68928 | None | ITEM15 | Providing and laying to required line and slope roofing with corrugated asbestos cement sheet 6mm. thick fixed with galvanised iron J or L hooks, bolts and nuts 8mm. dia C.I plain and bitumen washers over the existing purlins, rafters and trusses including cost of materials, labour, complete as per specifications. PWD SR Vol-II I.No.7.17 Page No.23 | Sqm | 348.6 | 348.6 | 23.89 | False | None | None | False | None | False | 8328.054 | 0 | | 2331314 | 68928 | None | ITEM16 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern. PWD CSR Vol-II 2023-24 P.No.131, I.No.14.4.1 | Each | 4676.7 | 4676.7 | 9.0 | False | None | None | False | None | False | 42090.3 | 0 | | 2331315 | 68928 | None | ITEM17 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Angle back wash basin size 400 x 400 mm with single 15 mm C.P. brass pillar tap. PWD CSR Vol-II 2023-24 P.No.133, I.No.14.7.6 | Each | 2378.25 | 2378.25 | 5.0 | False | None | None | False | None | False | 11891.25 | 0 | | 2331316 | 68928 | None | ITEM18 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Flexible pipe.40 mm dia PWD CSR Vol-II 2023-24 P.No.136, I.No.14.28.2.2 | Each | 96.6 | 96.6 | 5.0 | False | None | None | False | None | False | 483.0 | 0 | | 2331317 | 68928 | None | ITEM19 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm PWD CSR Vol-II 2023-24 P.No.136, I.No.14.32.2 | Each | 1068.9 | 1068.9 | 5.0 | False | None | None | False | None | False | 5344.5 | 0 | | 2331318 | 68928 | None | ITEM20 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. PWD CSR Vol-II 2023-24 P.No.123, I.No.13.34 | Ltr | 9.45 | 9.45 | 800.0 | False | None | None | False | None | False | 7560.0 | 0 | | 2331319 | 68928 | None | ITEM21 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete for: PVC pipes 32mm dia., 10 kg/sqcm & class 5. PWD CSR Vol-V 2023-24 P.No.113, I.No.10.1.2 | Mtr | 70.35 | 70.35 | 26.0 | False | None | None | False | None | False | 1829.1 | 0 | | 2331320 | 68928 | None | ITEM22 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall. 25 mm nominal dia Pipes PWD CSR Vol-II 2023-24 P.No.122, I.No.13.31.3 | Mtr | 333.9 | 333.9 | 26.0 | False | None | None | False | None | False | 8681.4 | 0 | | 2331321 | 68928 | None | ITEM23 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 32 mm nominal bore. PWD CSR Vol-II 2023-24 P.No.117, I.No.13.4.2 | No | 627.9 | 627.9 | 6.0 | False | None | None | False | None | False | 3767.4 | 0 | | 2331322 | 68928 | None | ITEM24 | Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 19/20 mm dia 2 mm thick PWD CSR Vol-VI 2023-24 Chapter-1 P.No.2, I.No.1.1.1 | Mtr | 72.45 | 72.45 | 40.0 | False | None | None | False | None | False | 2898.0 | 0 | | 2331323 | 68928 | None | ITEM25 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990. 2C x 4 mm2 PWD CSR Vol-VI 2023-24 Chapter-2 P.No.6, I.No.2.5.14 | Mtr | 129.15 | 129.15 | 50.0 | False | None | None | False | None | False | 6457.5 | 0 | | 2331324 | 68928 | None | ITEM26 | Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3854. 6A 2 Way PWD CSR Vol-VI 2023-24 Chapter-3 P.No.8, I.No.3.1.1 | Each | 134.4 | 134.4 | 5.0 | False | None | None | False | None | False | 672.0 | 0 | | 2331325 | 68928 | None | ITEM27 | Supplying and mounting 2 Nos. of 2Way 6 A flush type switches either surface/flush mounted on existing gang box or in 4mm thick plastic sheet and mounted on a flush mounted wooden box and wiring as per IS 3854 PWD CSR Vol-VI 2023-24 Chapter-3 P.No.8, I.No.3.2 | Each | 178.5 | 178.5 | 5.0 | False | None | None | False | None | False | 892.5 | 0 | | 2331326 | 68928 | None | ITEM28 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 1-2 Way PWD CSR Vol-VI 2023-24 Chapter-3 P.No.8, I.No.3.3.1 | Each | 108.15 | 108.15 | 5.0 | False | None | None | False | None | False | 540.75 | 0 | | 2331327 | 68928 | None | ITEM29 | Supplying & fixing of retrofit type -LED bulb 9W, 6500Kwith OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per W, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.PWD CSR Vol-VI 2023-24 Chapter-11 P.No.47, I.No.11.11.4 | Each | 161.7 | 161.7 | 10.0 | False | None | None | False | None | False | 1617.0 | 0 |
|