| 1706596553000 | 0 | None | None | Water supply/sewage lines | Drilling of borewell fixing of motor and construction of Costern in Ward no 04 Near yallamma Temple In Ward no 21 Near Duragamma temple In ward no 22 at Mallikarjun layout gardnen site and in ward no 07 Jani Kattige Adda in maski TMC limits | 673262.1 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 2335745 | 69016 | None | code01 | Geophysical investigation at site for sinking borewells for supplying drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers’s method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test. | Each | 5552.4 | 5552.4 | 6.0 | False | None | None | False | None | False | 33314.4 | 0 | | 2335746 | 69016 | None | code02 | Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc.) for: Borewell depth of 0 to 50 m | Mtr | 324.45 | 324.45 | 300.0 | False | None | None | False | None | False | 97335.0 | 0 | | 2335747 | 69016 | None | code03 | Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc.) for: Borewell depth of 50 to 100 m | Mtr | 406.35 | 406.35 | 180.0 | False | None | None | False | None | False | 73143.0 | 0 | | 2335748 | 69016 | None | code04 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: PVC Casing pipes 140mm dia, 6 kg/sqcm & class 3 | Mtr | 613.2 | 613.2 | 180.0 | False | None | None | False | None | False | 110376.0 | 0 | | 2335749 | 69016 | None | code05 | Providing Submersible Pump Set of 150mm dia suitable for bore well and
confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt
Motor as per specifications, to work site as per necessary ammendments
and instructions of engineer incharge of work. For 5HP etc. complete | Each | 27625.5 | 27625.5 | 2.0 | False | None | None | False | None | False | 55251.0 | 0 | | 2335750 | 69016 | None | code06 | Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments. 1x3X6 | Mtr | 194.25 | 194.25 | 360.0 | False | None | None | False | None | False | 69930.0 | 0 | | 2335751 | 69016 | None | code07 | Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor typ e NOTE: 1) DOLDirect Online Starter 2) S-D- Star Delta Starter Upto 6 HP pumps | Each | 10027.5 | 10027.5 | 6.0 | False | None | None | False | None | False | 60165.0 | 0 | | 2335752 | 69016 | None | code08 | Supply and delivery at site delivery of best indigenous brand new MCB (Miniature Circuit Breakers) of required capacity as per IS 88228/1978 and its latest amendments and with ISI Mark of 6/10/16/20/25/40 Amps with scalable box | Each | 1207.5 | 1207.5 | 6.0 | False | None | None | False | None | False | 7245.0 | 0 | | 2335753 | 69016 | None | code09 | Providing main connection from pole PVC insulated sheathed steel wire cable in GI pipe as per IS 1554/ 1988 with latest amendments with ISI mark from KPTCL pole to meter board unit. | Mtr | 89.25 | 89.25 | 330.0 | False | None | None | False | None | False | 29452.5 | 0 | | 2335754 | 69016 | None | code10 | Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990
with latest amendments complete with GI fittings (excluding the cost
of fittings) with cuts and threads wherever necessary, including testing
for water tightness, with all lead and commissioning. (contractor will
make his own arrangements for procuring water for testing) For:Heavy DUTYGI PIPE ETC COMPLTE 65MM | Mtr | 701.4 | 701.4 | 80.0 | False | None | None | False | None | False | 56112.0 | 0 | | 2335755 | 69016 | None | code11 | Providing, supplying to work site,Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications,with testing of as per instructions of engineer incharge of work and latest amendments. 0.75 KW 12 STG | Each | 15241.8 | 15241.8 | 4.0 | False | None | None | False | None | False | 60967.2 | 0 | | 2335756 | 69016 | None | code12 | Supply and delivery at site Accessories for Single Phase pumpset like SS Groove Nipples,SS Studs & Nuts,Screw Clips &water proof Insulation Tape etc complete with ISI mark | Set | 4725.0 | 4725.0 | 2.0 | False | None | None | False | None | False | 9450.0 | 0 | | 2335757 | 69016 | None | code13 | Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990
with latest amendments complete with GI fittings (excluding the cost
of fittings) with cuts and threads wherever necessary, including testing
for water tightness, with all lead and commissioning. (contractor will
make his own arrangements for procuRING WATER FOR TESTING .32MM | Mtr | 350.7 | 350.7 | 30.0 | False | None | None | False | None | False | 10521.0 | 0 |
|