tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1705593277000 | 0 | None | None | Buildings | CONSTRUCTION OF FOUR CLASS ROOM TO GOVERNMENT HIGHER PRIMARY & HIGH SCHOOL AT BIRAL (B) VILLAGE IN JEWARGI TALUKA DIST KALABURAGI UNDER KKRDB MICRO FOR THE YEAR 2023-24 | 3883216.84 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2221924 | 65038 | None | Item No.1.5.1 Page No.6, Vol - I PWD CSR - 2023-24 | Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depth | Cum | 313.95 | 313.95 | 127.3 | False | None | None | False | None | False | 39965.835 | 0 | 2221925 | 65038 | None | Item No.1.9, Page No.7, Vol - I | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 279.3 | 279.3 | 101.83 | False | None | None | False | None | False | 28441.119 | 0 | 2221926 | 65038 | None | Item No. 1.8, Page No.7, Vol - I | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all
materials,usage& all other appurtenaces required to complete the work. | Cum | 497.7 | 497.7 | 119.97 | False | None | None | False | None | False | 59709.069 | 0 | 2221927 | 65038 | None | Item No.2.1.2, Page No.15, Vol - I | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5947.2 | 5947.2 | 26.47 | False | None | None | False | None | False | 157422.384 | 0 | 2221928 | 65038 | None | Item No.2.5.1, Page No.16, Vol - I | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6961.5 | 6961.5 | 10.57 | False | None | None | False | None | False | 73583.055 | 0 | 2221929 | 65038 | None | Vol-I S R Sl no. 1 (b) page no. 111 | Addendum I-Percentage Additionalities for Formwork,
Centering & Scaffolding for Foundation upto Plinth All other types add 8 Percent | Cum | 556.92 | 556.92 | 10.57 | False | None | None | False | None | False | 5886.6444 | 0 | 2221930 | 65038 | None | Item No.2.5.1, Page No.16, Vol - I | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6961.5 | 6961.5 | 9.56 | False | None | None | False | None | False | 66551.94 | 0 | 2221931 | 65038 | None | Vol-I S R Sl No. 9 page No. 111 | Addendum I-Percentage Additionalities for Formwork,
Centering & Scaffolding for RCC Columns / Shaft (Slip Centering) add 70 percent | Cum | 4873.05 | 4873.05 | 9.56 | False | None | None | False | None | False | 46586.358 | 0 | 2221932 | 65038 | None | Item No.2.5.1, Page No.16, Vol - I | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6961.5 | 6961.5 | 8.18 | False | None | None | False | None | False | 56945.07 | 0 | 2221933 | 65038 | None | Vol-I S R Sl no. 2 Page No. 111 | Addendum I-Percentage Additionalities for Formwork,
Centering & Scaffolding for Plinth Beams of Buildings add 50 Percent | Cum | 3480.75 | 3480.75 | 8.18 | False | None | None | False | None | False | 28472.535 | 0 | 2221934 | 65038 | None | Item No.2.5.1, Page No.16, Vol - I | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6961.5 | 6961.5 | 19.22 | False | None | None | False | None | False | 133800.03 | 0 | 2221935 | 65038 | None | Vol-I S R Sl no. 14 Page No. 112 | Addendum I-Percentage Additionalities for Formwork,
Centering & Scaffolding RCC Beams, Lintels & Troughs of Aqueducts add 60 Percent | Cum | 4176.9 | 4176.9 | 19.22 | False | None | None | False | None | False | 80280.018 | 0 | 2221936 | 65038 | None | Item No.2.5.1, Page No.16, Vol - I | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6961.5 | 6961.5 | 33.79 | False | None | None | False | None | False | 235229.085 | 0 | 2221937 | 65038 | None | Vol-I S R SL no. 15 Page No. 112 | Addendum I-Percentage Additionalities for Formwork,
Centering & Scaffolding for RCC Roof Slabs add 50 Percent | Cum / K | 3480.75 | 3480.75 | 33.79 | False | None | None | False | None | False | 117614.5425 | 0 | 2221938 | 65038 | None | Item No.2.5.1, Page No.16, Vol - I | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6961.5 | 6961.5 | 0.4 | False | None | None | False | None | False | 2784.6 | 0 | 2221939 | 65038 | None | Vol-I S R SL No. 19 Page No. 112 | Addendum I-Percentage Additionalities for Formwork,
Centering & Scaffolding Chejjas, Canopy & Other Architectural projections of
minor sections add 45 Perecnt | Cum | 3132.67 | 3132.67 | 0.4 | False | None | None | False | None | False | 1253.068 | 0 | 2221940 | 65038 | None | Item No.5.1.1, Page No.9, Vol - 2 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement: 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 5891.55 | 5891.55 | 55.13 | False | None | None | False | None | False | 324801.1515 | 0 | 2221941 | 65038 | None | Item No.5.4, Page No.9, Vol - 2 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6708.45 | 6708.45 | 33.94 | False | None | None | False | None | False | 227684.793 | 0 | 2221942 | 65038 | None | Item No.6.8, Page No.14, Vol - 2 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of
work. | Cum | 8367.45 | 8367.45 | 68.64 | False | None | None | False | None | False | 574341.768 | 0 | 2221943 | 65038 | None | Item No.8.2.2, Page No.41, Vol - 2 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-Charge | Sqm | 292.95 | 292.95 | 530.94 | False | None | None | False | None | False | 155538.873 | 0 | 2221944 | 65038 | None | Item No.8.1.2, Page No.41, Vol - 2 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 253.05 | 253.05 | 215.45 | False | None | None | False | None | False | 54519.6225 | 0 | 2221945 | 65038 | None | Item No.12.13.1 Page No.100, Vol - 2 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 103755.75 | 103755.75 | 0.33 | False | None | None | False | None | False | 34239.3975 | 0 | 2221946 | 65038 | None | Item No.12.21 Page No.100, Vol - 2 | Providing and fixing in position fully panelled Matti/Nandi wood shutters for doors with , stiles and rails of 30mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures) | Sqm | 6029.1 | 6029.1 | 7.56 | False | None | None | False | None | False | 45579.996 | 0 | 2221947 | 65038 | None | Item No.12.51 Page No.104, Vol - 2 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. | No | 1066.8 | 1066.8 | 4.0 | False | None | None | False | None | False | 4267.2 | 0 | 2221948 | 65038 | None | Item No. 9.35 Page No.64, Vol - 2 | Flooring with 25mm thick polished shahabad slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications. | Sqm | 1717.8 | 1717.8 | 228.22 | False | None | None | False | None | False | 392036.316 | 0 | 2221949 | 65038 | None | Item No.11.44 Page No.91, Vol - 2 | Providing and fixing double glazed hermetically sealed glazing in alu minium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of
Engineer-in-charge complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Sqm | 4562.25 | 4562.25 | 23.76 | False | None | None | False | None | False | 108399.06 | 0 | 2221950 | 65038 | None | Item No.11.34.B Page No.86, Vol - 2 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. | Kg | 192.15 | 192.15 | 498.96 | False | None | None | False | None | False | 95875.164 | 0 | 2221951 | 65038 | None | Item No.8.34.1 Page No.47, Vol - 2 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as perspecifications and as per directions of Engineer-in-charge. | Sqm | 55.65 | 55.65 | 19.66 | False | None | None | False | None | False | 1094.079 | 0 | 2221952 | 65038 | None | Item No.8.33.2 Page No.46, Vol - 2 | Painting wood work with Deluxe Multi Surface Paint of requiredshade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 144.9 | 144.9 | 19.66 | False | None | None | False | None | False | 2848.734 | 0 | 2221953 | 65038 | None | Item No.8.33.3 Page No.47, Vol - 2 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 145.95 | 145.95 | 23.76 | False | None | None | False | None | False | 3467.772 | 0 | 2221954 | 65038 | None | Item No.8.51, Page No.50, Vol - 2 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 105.0 | 105.0 | 609.32 | False | None | None | False | None | False | 63978.6 | 0 | 2221955 | 65038 | None | Item No.8.25, Page No.45, Vol - 2 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 143.85 | 143.85 | 609.32 | False | None | None | False | None | False | 87650.682 | 0 | 2221956 | 65038 | None | Item No.8.29, Page No.45, Vol - 2 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 297.15 | 297.15 | 149.47 | False | None | None | False | None | False | 44415.0105 | 0 | 2221957 | 65038 | None | Item No.2.11 (a) Vol-I 2023-24 S R Page No. 18 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification Buildings | t | 93929.85 | 93929.85 | 5.52 | False | None | None | False | None | False | 518492.772 | 0 | 2221958 | 65038 | None | I No. 8.7 Vol-III 2023-24 S R Page No. 65 | Providing and erecting direction and place identification retro reflectorised sign as per IRC:67:2022 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick or Aluminium composite material sheet with overall thickness of 4mm with area not exceeding 0.9 m2 fixed over back support frame of min 35 x 35 x 3mm angle mounted on a mild steel circular pipe 65 NB, firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 x 45 x 60 cm, 60 cm below ground level as per approved drawing | Sqm | 9460.5 | 9460.5 | 1.0 | False | None | None | False | None | False | 9460.5 | 0 |
| 1705593277000 | 0 | None | None | Buildings | FISRT FLOOR | 2821135.75 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2221959 | 65039 | None | Item No.2.5.1, Page No.16, Vol - I | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7031.11 | 7031.11 | 9.56 | False | None | None | False | None | False | 67217.4116 | 0 | 2221960 | 65039 | None | Vol-I S R Sl No. 9 page No. 111 | Addendum I-Percentage Additionalities for Formwork,
Centering & Scaffolding for RCC Columns / Shaft (Slip Centering) add 70 percent | Cum | 4921.78 | 4921.78 | 9.56 | False | None | None | False | None | False | 47052.2168 | 0 | 2221961 | 65039 | None | Item No.2.5.1, Page No.16, Vol - I | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7031.11 | 7031.11 | 19.47 | False | None | None | False | None | False | 136895.7117 | 0 | 2221962 | 65039 | None | Vol-I S R Sl no. 14 Page No. 112 | Addendum I-Percentage Additionalities for Formwork,
Centering & Scaffolding RCC Beams, Lintels & Troughs of Aqueducts add 60 Percent | Cum | 4218.67 | 4218.67 | 19.47 | False | None | None | False | None | False | 82137.5049 | 0 | 2221963 | 65039 | None | Item No.2.5.1, Page No.16, Vol - I | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7031.11 | 7031.11 | 33.79 | False | None | None | False | None | False | 237581.2069 | 0 | 2221964 | 65039 | None | Vol-I S R SL no. 15 Page No. 112 | Addendum I-Percentage Additionalities for Formwork,
Centering & Scaffolding for RCC Roof Slabs add 50 Percent | Cum / K | 3515.56 | 3515.56 | 33.79 | False | None | None | False | None | False | 118790.7724 | 0 | 2221965 | 65039 | None | Item No.2.5.1, Page No.16, Vol - I | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7031.11 | 7031.11 | 0.4 | False | None | None | False | None | False | 2812.444 | 0 | 2221966 | 65039 | None | Vol-I S R SL No. 19 Page No. 112 | Addendum I-Percentage Additionalities for Formwork,
Centering & Scaffolding Chejjas, Canopy & Other Architectural projections of
minor sections add 45 Perecnt | Cum | 3164.0 | 3164.0 | 0.4 | False | None | None | False | None | False | 1265.6 | 0 | 2221967 | 65039 | None | Item No.6.8, Page No.14, Vol - 2 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of
work. | Cum | 8451.12 | 8451.12 | 68.64 | False | None | None | False | None | False | 580084.8768 | 0 | 2221968 | 65039 | None | Item No.8.2.2, Page No.41, Vol - 2 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-Charge | Sqm | 295.88 | 295.88 | 530.94 | False | None | None | False | None | False | 157094.5272 | 0 | 2221969 | 65039 | None | Item No.8.1.2, Page No.41, Vol - 2 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 255.58 | 255.58 | 226.31 | False | None | None | False | None | False | 57840.3098 | 0 | 2221970 | 65039 | None | Item No.12.13.1 Page No.100, Vol - 2 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 104793.31 | 104793.31 | 0.33 | False | None | None | False | None | False | 34581.7923 | 0 | 2221971 | 65039 | None | Item No.12.21 Page No.100, Vol - 2 | Providing and fixing in position fully panelled Matti/Nandi wood shutters for doors with , stiles and rails of 30mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures) | Sqm | 6089.39 | 6089.39 | 7.56 | False | None | None | False | None | False | 46035.7884 | 0 | 2221972 | 65039 | None | Item No.12.51 Page No.104, Vol - 2 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. | No | 1077.47 | 1077.47 | 4.0 | False | None | None | False | None | False | 4309.88 | 0 | 2221973 | 65039 | None | Item No. 9.12.2 Page No.60, Vol - 2 | Providing and laying vitrified floor tiles with thickness 9-10 mm in
different sizes with water absorption less than 0.08% and conforming to
IS: 15622, of approved make, in all colours and shades, laid on 20mm thick
cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement
slurry @ 3.3 kg/ m2 including grouting the joints with white cement and
matching pigments etc., complete. Size of Tile 600x600 mm | Sqm | 1214.27 | 1214.27 | 239.08 | False | None | None | False | None | False | 290307.6716 | 0 | 2221974 | 65039 | None | Item No.11.44 Page No.91, Vol - 2 | Providing and fixing double glazed hermetically sealed glazing in alu minium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of
Engineer-in-charge complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Sqm | 4607.87 | 4607.87 | 23.76 | False | None | None | False | None | False | 109482.9912 | 0 | 2221975 | 65039 | None | Item No.11.34.B Page No.86, Vol - 2 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. | Kg | 194.07 | 194.07 | 498.96 | False | None | None | False | None | False | 96833.1672 | 0 | 2221976 | 65039 | None | Item No.8.34.1 Page No.47, Vol - 2 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as perspecifications and as per directions of Engineer-in-charge. | Sqm | 56.21 | 56.21 | 19.66 | False | None | None | False | None | False | 1105.0886 | 0 | 2221977 | 65039 | None | Item No.8.33.2 Page No.46, Vol - 2 | Painting wood work with Deluxe Multi Surface Paint of requiredshade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 146.35 | 146.35 | 19.66 | False | None | None | False | None | False | 2877.241 | 0 | 2221978 | 65039 | None | Item No.8.33.3 Page No.47, Vol - 2 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 147.41 | 147.41 | 23.76 | False | None | None | False | None | False | 3502.4616 | 0 | 2221979 | 65039 | None | Item No.8.51, Page No.50, Vol - 2 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 106.05 | 106.05 | 609.32 | False | None | None | False | None | False | 64618.386 | 0 | 2221980 | 65039 | None | Item No.8.25, Page No.45, Vol - 2 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 145.29 | 145.29 | 609.32 | False | None | None | False | None | False | 88528.1028 | 0 | 2221981 | 65039 | None | Item No.8.29, Page No.45, Vol - 2 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 300.12 | 300.12 | 149.47 | False | None | None | False | None | False | 44858.9364 | 0 | 2221982 | 65039 | None | Item No.2.11 (a) Vol-I 2023-24 S R Page No. 18 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification Buildings | t | 93859.15 | 93859.15 | 5.81 | False | None | None | False | None | False | 545321.6615 | 0 |
| 1705593277000 | 0 | None | None | Buildings | ELECTRICAL WORK | 273682.0 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2221983 | 65040 | None | 1.2.1 | Concealed Conduit System Supplying heavy gauge PVC conduit pipe mm dia .mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25mm dia 2mm thick | Mtr | 66.0 | 66.0 | 400.0 | False | None | None | False | None | False | 26400.0 | 0 | 2221984 | 65040 | None | 1.3.2 | Supplying heavy gauge PVC Conduit Pipe .dia .mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.25mm dia 2mm thick | Mtr | 79.0 | 79.0 | 400.0 | False | None | None | False | None | False | 31600.0 | 0 | 2221985 | 65040 | None | 1.5.2 | Supplying and fixing PVC/metal conduit Deep junction box 25mm deep junction box | Mtr | 56.0 | 56.0 | 20.0 | False | None | None | False | None | False | 1120.0 | 0 | 2221986 | 65040 | None | 1.6.3 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, Finishing with necessary cement plastering complete 10"x7"x3" (254x178x76mm) | Mtr | 112.0 | 112.0 | 16.0 | False | None | None | False | None | False | 1792.0 | 0 | 2221987 | 65040 | None | 1.12 | Supplying And Fixing Metal Fan Box with Round Hook. | No | 160.0 | 160.0 | 16.0 | False | None | None | False | None | False | 2560.0 | 0 | 2221988 | 65040 | None | 2.1.1 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Short point upto 3Mtr from tapping point to out let via switch | Point | 285.0 | 285.0 | 16.0 | False | None | None | False | None | False | 4560.0 | 0 | 2221989 | 65040 | None | 2.1.2 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch | Point | 394.0 | 394.0 | 16.0 | False | None | None | False | None | False | 6304.0 | 0 | 2221990 | 65040 | None | 2.1.3 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Long point above 6Mtr upto 10Mtr from tapping point to out let via switch | Point | 570.0 | 570.0 | 16.0 | False | None | None | False | None | False | 9120.0 | 0 | 2221991 | 65040 | None | 2.5.2 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS:8130-1984 and (Virgin) PVC insulation sheathed suitabl 3C X 1.5Sq.mm | Mtr | 72.0 | 72.0 | 400.0 | False | None | None | False | None | False | 28800.0 | 0 | 2221992 | 65040 | None | 2.5.3 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS:8130-1984 and (Virgin) PVC insulation sheathed suitabl 4C X 1.5Sq.mm | Mtr | 94.0 | 94.0 | 400.0 | False | None | None | False | None | False | 37600.0 | 0 | 2221993 | 65040 | None | Electrical DSR It.no 3.1.1 | Supplying 6A flush type socket and 6 amps flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 6Amps 2 Way | Each | 128.0 | 128.0 | 16.0 | False | None | None | False | None | False | 2048.0 | 0 | 2221994 | 65040 | None | 3.14.2 | Supplying and fixing/replacing of 6/16/32Amps electrical accessories on existing switch board.6Amps 2way Switch | No | 70.0 | 70.0 | 16.0 | False | None | None | False | None | False | 1120.0 | 0 | 2221995 | 65040 | None | 3.5.1 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.1 to 3 Module | Each | 137.0 | 137.0 | 76.0 | False | None | None | False | None | False | 10412.0 | 0 | 2221996 | 65040 | None | 3.5.4 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.6 Module | Each | 234.0 | 234.0 | 20.0 | False | None | None | False | None | False | 4680.0 | 0 | 2221997 | 65040 | None | 3.8 | Supplying and fixing hylum plastic sheet 3mm thick with necessary nitches for fixing switches, regulators etc., and fixing on existing wood or metal box using N.F. screws. | Sq CM | 0.41 | 0.41 | 80000.0 | False | None | None | False | None | False | 32800.0 | 0 | 2221998 | 65040 | None | 6.3.2 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. | Each | 3031.0 | 3031.0 | 16.0 | False | None | None | False | None | False | 48496.0 | 0 | 2221999 | 65040 | None | 13.7.1 | Fixing all types and all capacities of fluorescent / false ceiling/ spot light / CFL / LED fittings indoor on the wall / ceiling /rafters / girders using 23/0.0076 twin twisted PVC insulatedwires, required Nos of round blocks and clamps. | Each | 122.0 | 122.0 | 32.0 | False | None | None | False | None | False | 3904.0 | 0 | 2222000 | 65040 | None | 13.11 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. | Each | 315.0 | 315.0 | 16.0 | False | None | None | False | None | False | 5040.0 | 0 | 2222001 | 65040 | None | 5.19.12 | Supplying and fixing regular MCB distribution boards on wall/ wood board / flush mounting using required clamps, bolts,nuts etc., with provision for fixing suitable type capacityMCB's single phase / 3 phase / single door with powdercoated painting. Made out of 14 SWG MS enclosure. | Each | 4940.0 | 4940.0 | 2.0 | False | None | None | False | None | False | 9880.0 | 0 | 2222002 | 65040 | None | 5.18.1 | Supplying and fixing miniature circuit breakers on existingMCB distribution boards using necessary fixing materialsand 'C' Type curve, indicator ON/OFF, energy cross-3 withShort circuit breaking capacity of 10K and complete wiringas required confirming to IEC 60898 | Each | 415.0 | 415.0 | 6.0 | False | None | None | False | None | False | 2490.0 | 0 | 2222003 | 65040 | None | 5.18.4 | Supplying and fixing miniature circuit breakers on existingMCB distribution boards using necessary fixing materialsand 'C' Type curve, indicator ON/OFF, energy cross-3 withShort circuit breaking capacity of 10K and complete wiringas required confirming to IEC 60898. | Each | 739.0 | 739.0 | 4.0 | False | None | None | False | None | False | 2956.0 | 0 |
|
|
---|