tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1706095894000 | 0 | None | None | Buildings | Construction of Library Building in Alur Village, Jewargi Taluka in Kalaburagi Dist. Under KKRDB Micro for the year 2023-24.(KLB231023366) | 1208516.35 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2288108 | 67380 | None | 1.17.1 | Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depth | Cum | 226.8 | 226.8 | 39.01 | False | None | None | False | None | False | 8847.468 | 0 | 2288109 | 67380 | None | Item No.2.1.2, Page No.15, Vol - I | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5947.2 | 5947.2 | 5.44 | False | None | None | False | None | False | 32352.768 | 0 | 2288110 | 67380 | None | Item No.2.2.1.1, Page No.16, Vol - I | Providing and laying in position Reinforced cement concrete for all
Foundation works. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine
mixed with super plasticizers laid in finished layers, well compacted
using needle vibrators, including all lead & lifts, cost of all materials,
quality confirming to the requirements of relevant IS codes , labour,
Usage charges of machinery, curing and all the other appurtenances
required to complete the work as per technical specifications. (The cost
of steel reinforcement & formwork to be paid separately) | Cum | 6542.55 | 6542.55 | 8.1 | False | None | None | False | None | False | 52994.655 | 0 | 2288111 | 67380 | None | Vol-I S R Sl no. 1 (b) page no. 111 | Addendum I-Percentage Additionalities for Formwork,
Centering & Scaffolding for Foundation upto Plinth All other types add 8 Percent | Cum | 523.4 | 523.4 | 8.1 | False | None | None | False | None | False | 4239.54 | 0 | 2288112 | 67380 | None | Item No.2.2.1.1, Page No.15, Vol - I | Providing and laying in position Reinforced cement concrete for all
Foundation works. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine
mixed with super plasticizers laid in finished layers, well compacted
using needle vibrators, including all lead & lifts, cost of all materials,
quality confirming to the requirements of relevant IS codes , labour,
Usage charges of machinery, curing and all the other appurtenances
required to complete the work as per technical specifications. (The cost
of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse
aggregates | Cum | 6542.55 | 6542.55 | 4.02 | False | None | None | False | None | False | 26301.051 | 0 | 2288113 | 67380 | None | Vol-I S R Sl No. 9 page No. 111 | Addendum I-Percentage Additionalities for Formwork,
Centering & Scaffolding for RCC Columns / Shaft (Slip Centering) add 70 percent | Cum | 4579.78 | 4579.78 | 4.02 | False | None | None | False | None | False | 18410.7156 | 0 | 2288114 | 67380 | None | Item No.2.2.1.1 Page No.15, Vol - I | Providing and laying in position Reinforced cement concrete for all
Foundation works. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine
mixed with super plasticizers laid in finished layers, well compacted
using needle vibrators, including all lead & lifts, cost of all materials,
quality confirming to the requirements of relevant IS codes , labour,
Usage charges of machinery, curing and all the other appurtenances
required to complete the work as per technical specifications. (The cost
of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse
aggregates | Cum | 6542.55 | 6542.55 | 1.94 | False | None | None | False | None | False | 12692.547 | 0 | 2288115 | 67380 | None | Vol-I S R Sl no. 2 Page No. 111 | Addendum I-Percentage Additionalities for Formwork,
Centering & Scaffolding for Plinth Beams of Buildings add 50 Percent | Cum | 3271.27 | 3271.27 | 1.94 | False | None | None | False | None | False | 6346.2638 | 0 | 2288116 | 67380 | None | Item No.2.2.1.1, Page No.15, Vol - I | Providing and laying in position Reinforced cement concrete for all
Foundation works. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine
mixed with super plasticizers laid in finished layers, well compacted
using needle vibrators, including all lead & lifts, cost of all materials,
quality confirming to the requirements of relevant IS codes , labour,
Usage charges of machinery, curing and all the other appurtenances
required to complete the work as per technical specifications. (The cost
of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse
aggregates | Cum | 6542.55 | 6542.55 | 4.42 | False | None | None | False | None | False | 28918.071 | 0 | 2288117 | 67380 | None | Vol-I S R Sl no. 14 Page No. 112 | Addendum I-Percentage Additionalities for Formwork,
Centering & Scaffolding RCC Beams, Lintels & Troughs of Aqueducts add 60 Percent | Cum | 3925.53 | 3925.53 | 4.42 | False | None | None | False | None | False | 17350.8426 | 0 | 2288118 | 67380 | None | Item No.2.2.1.1, Page No.15, Vol - I | Providing and laying in position Reinforced cement concrete for all
Foundation works. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine
mixed with super plasticizers laid in finished layers, well compacted
using needle vibrators, including all lead & lifts, cost of all materials,
quality confirming to the requirements of relevant IS codes , labour,
Usage charges of machinery, curing and all the other appurtenances
required to complete the work as per technical specifications. (The cost
of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse
aggregates | Cum | 6542.55 | 6542.55 | 5.61 | False | None | None | False | None | False | 36703.7055 | 0 | 2288119 | 67380 | None | Vol-I S R SL no. 15 Page No. 112 | Addendum I-Percentage Additionalities for Formwork,
Centering & Scaffolding for RCC Roof Slabs add 50 Percent | Cum / K | 3271.27 | 3271.27 | 5.61 | False | None | None | False | None | False | 18351.8247 | 0 | 2288120 | 67380 | None | Item No.2.2.1.1 Page No.15, Vol - I | Providing and laying in position Reinforced cement concrete for all
Foundation works. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine
mixed with super plasticizers laid in finished layers, well compacted
using needle vibrators, including all lead & lifts, cost of all materials,
quality confirming to the requirements of relevant IS codes , labour,
Usage charges of machinery, curing and all the other appurtenances
required to complete the work as per technical specifications. (The cost
of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse
aggregates | Cum | 6542.55 | 6542.55 | 0.57 | False | None | None | False | None | False | 3729.2535 | 0 | 2288121 | 67380 | None | Vol-I S R SL No. 19 Page No. 112 | Addendum I-Percentage Additionalities for Formwork,
Centering & Scaffolding Chejjas, Canopy & Other Architectural projections of
minor sections add 45 Perecnt | Cum | 2944.15 | 2944.15 | 0.57 | False | None | None | False | None | False | 1678.1655 | 0 | 2288122 | 67380 | None | Item No.5.1.1, Page No.9, Vol - 2 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement: 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 5891.55 | 5891.55 | 10.94 | False | None | None | False | None | False | 64453.557 | 0 | 2288123 | 67380 | None | Item No.5.4, Page No.9, Vol - 2 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6708.45 | 6708.45 | 6.24 | False | None | None | False | None | False | 41860.728 | 0 | 2288124 | 67380 | None | Item No.6.7, Page No.13, Vol - 2 | Providing Brick work with common burnt clay Non Modular bricks of
class designation 3.5 in superstructure above plinth level in all shapes and
sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of
all materials, labour, scaffolding and usage charges of machinery & other
incidental charges complete as per the direction of engineer incharge of
work. | Cum | 8621.55 | 8621.55 | 20.84 | False | None | None | False | None | False | 179673.102 | 0 | 2288125 | 67380 | None | Vol-I S R 2023-24 Page No. 7 I No. 1.10 | Refilling available earth around trenches/pipelines, cables in layers not
exceeding 20 cms in depth, compacting each deposited layer by ramming after
watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour
complete as per specifications | Cum | 168.0 | 168.0 | 43.32 | False | None | None | False | None | False | 7277.76 | 0 | 2288126 | 67380 | None | Vol-II I No. 12.11 Page No. 99 | Providing Honne wood frames of doors, windows, clerestory windows,
ventilators and other frames, wrought, framed or assembled including
making plaster groves (excluding cost of cement concrete and side clamps),
but including cost of materials, labour, usage charges complete as per
specifications. | Cum | 144977.7 | 144977.7 | 0.73 | False | None | None | False | None | False | 105833.721 | 0 | 2288127 | 67380 | None | Vol-II I No. 12.51 Page No. 104 | Fixing of door frame in an existing opening including embedding frame in
floor and walls after cutting masonry for holdfasts for embedding holdfast
in cement concrete 1:3:6 of 20mm and down size granite metal painting
two coats of coal tar to sides of frame, making good the damages to walls
and floor as required and disposal of the debris with lead upto 50 m.
including cost of materials, labour charges, complete as per specifications. | No | 1066.8 | 1066.8 | 3.0 | False | None | None | False | None | False | 3200.4 | 0 | 2288128 | 67380 | None | Vol-II I No. 12.52 Page No. 104 | Fixing of window frame in an existing opening including embedding frame
in floor and walls after cutting masonry for holdfasts for embedding
holdfast in cement concrete 1:3:6 of 20mm and down size granite metal
painting two coats of coal tar to sides of frame, making good the damages
to walls and floor as required and disposal of the debries with lead
upto 50 m. including cost of materials, labour charges, complete as per
specifications. | No | 811.65 | 811.65 | 6.0 | False | None | None | False | None | False | 4869.9 | 0 | 2288129 | 67380 | None | Vol-II I No. 12.20 Page No. 100 | Providing and fixing in position fully panelled Honne wood shutters for
doors with , stiles and rails of 30mm. thick with bottom and lock rails
180mm wide top rail and stiles 100mm wide as per drawing and panels
of 25mm thick including cost of materials, labour, usage charges complete
as per specifications. (excluding cost of fixtures ) | Sqm | 6457.5 | 6457.5 | 6.93 | False | None | None | False | None | False | 44750.475 | 0 | 2288130 | 67380 | None | Vol-II I No. 12.34 Page No. 102 | Providing and fixing in position fully panelled shutters for windows with
Honne wood stiles and rails of 25mm. thick, 75mm wide in two halves
with panels provided with MDF of 12mm thick including cost of materials,
labour charges, usage charges complete as per specifications. (excluding
cost of fixtures) | Sqm | 4963.35 | 4963.35 | 10.44 | False | None | None | False | None | False | 51817.374 | 0 | 2288131 | 67380 | None | Vol-II I No. 11.34A Page No. 86 | Providing and fixing M.S. grills of required pattern in frames of windows
etc. with M.S. flats, square or round bars etc. including priming coat with
approved steel primer all complete. Fixed to steel windows by welding | Kg | 176.4 | 176.4 | 219.24 | False | None | None | False | None | False | 38673.936 | 0 | 2288132 | 67380 | None | Vol-II I No. 8.5.2 Page No. 42 | Providing 15 mm cement plaster on rough side of single or half brick
wall finished with a floating coat of neat cement of mix: 1:4 (1 cement:
4 fine sand) to brick masonry including rounding off corners wherever
required smooth rendering, providing and removing scaffolding, including
cost of materials, labour, curing complete as per specifications and as per
directions of Engineer-in-charge. | Sqm | 366.45 | 366.45 | 113.38 | False | None | None | False | None | False | 41548.101 | 0 | 2288133 | 67380 | None | Vol-II I No. 8.4.1 Page No. 41 | Providing 12 mm cement plaster finished with a floating coat of neat
cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including
rounding off corners wherever required smooth rendering, providing and
removing scaffolding, including cost of materials, labour, curing complete
as per specifications and as per directions of Engineer-in-charge. | Sqm | 339.15 | 339.15 | 37.52 | False | None | None | False | None | False | 12724.908 | 0 | 2288134 | 67380 | None | Vol-II I No. 8.8 Page No. 42 | Providing 18 mm cement plaster in two coats under layer 12 mm thick
cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished
with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1
cement : 6 fine sand) to brick masonry including rounding off corners
wherever required smooth rendering, providing and removing scaffolding,
including cost of materials, labour, curing complete as per specifications
and as per directions of Engineer-in-charge. | Sqm | 389.55 | 389.55 | 112.31 | False | None | None | False | None | False | 43750.3605 | 0 | 2288135 | 67380 | None | Vol-I I No. 2.1.4 Page No. 15 | Providing and laying in position Cement Concrete for levelling course for
all works in foundation. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in
layers not exceeding 150 mm thickness, well compacted using plate vibrators,
including all lead & lifts, cost of all materials of quality, labour, Usage charges of
machinery, curing, and all the other appurtenances required to complete the
work as per technical specifications.Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6527.85 | 6527.85 | 3.1 | False | None | None | False | None | False | 20236.335 | 0 | 2288136 | 67380 | None | Vol-II I No. 9.19 Page No. 61 | Providing and laying Vitrified tiles with thickness 9-10 mm in different
sizes with water absorption less than 0.08% and conforming to IS: 15622,
of approved brand & manufacturer, in all colours and shade, in skirting,
riser, treads of steps, laid with cement based high polymer modified
quick set tile adhesive (water based) conforming to IS: 15477, in average
6 mm thickness, including grouting of joints as per direction of Engineer
in charge. | Sqm | 1231.65 | 1231.65 | 48.36 | False | None | None | False | None | False | 59562.594 | 0 | 2288137 | 67380 | None | Vol-II I No. 8.52.2 Page No. 50 | Distempering with 1st quality acrylic distemper, having VOC (Volatile
Organic Compound) content less than 50 g/L, of approved brand
and manufacture, including applying additional coats wherever required,
to achieve even shade and colour. Two coats as per specifications and as
per directions of Engineer in charge. | Sqm | 79.8 | 79.8 | 150.9 | False | None | None | False | None | False | 12041.82 | 0 | 2288138 | 67380 | None | Vol-II I No. 8.28 Page No. 45 | Finishing walls with water proofing cement paint of required shade :New
work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after
thoroughly brooming the surface to remove all dirt, dust, mortar drops
and foreign matter including preparing the surface even and sand paper
smooth, cost of materials, labour complete as per specifications and as per
directions of Engineer-in-charge. | Sqm | 93.45 | 93.45 | 112.31 | False | None | None | False | None | False | 10495.3695 | 0 | 2288139 | 67380 | None | Vol-II I No. 8.19.1 Page No. 44 | Providing Flush/ Ruled pointing: Pointing on stone work with cement
mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as
per directions of Engineer-in-charge | Sqm | 267.75 | 267.75 | 17.44 | False | None | None | False | None | False | 4669.56 | 0 | 2288140 | 67380 | None | Vol-III I No. 8.7 Page No. 65 | Providing and erecting direction and place identification retroreflectorised sign as per IRC:67:2022 made of high intensity
grade sheeting vide clause 801.3, fixed over aluminium
sheeting, 2 mm thick or Aluminium composite material sheet
with overall thickness of 4mm with area not exceeding 0.9
m2
fixed over back support frame of min 35 x 35 x 3mm angle
mounted on a mild steel circular pipe 65 NB, firmly fixed to the
ground by means of properly designed foundation with M25
grade cement concrete 45 x 45 x 60 cm, 60 cm below ground
level as per approved drawing | Sqm | 9460.5 | 9460.5 | 1.08 | False | None | None | False | None | False | 10217.34 | 0 | 2288141 | 67380 | None | Vol-I S R I No. 2.11(a) Page No. 18 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement
including cost of all materials, machinery, labour, cleaning, straightening,
cutting, bending, hooking, laping/welding joints, tying with binding wire / soft
annealed steel wire and other ancilary operations complete as per drawing and
technical specification.Buildings | t | 93929.85 | 93929.85 | 1.937 | False | None | None | False | None | False | 181942.11945 | 0 |
| 1706095894000 | 0 | None | None | Buildings | ELECTRICAL WORK | 61826.0 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2288142 | 67381 | None | 1.2.2 | Supplying heavy gauge PVC conduit pipe . mm dia.mm thick
confirming to IS 2509 with suitable size bends, metal/PVC Junction
boxes, adhesive paste etc., and running before concreting the slab. The
conduit should be tied to the reinforcement rods by using binding
wires and unused ways of junction boxes and pipe ends should be
covered using PVC end enclosures, run with 18SWG GI fish wire
wherever necessary 25 mm dia 2 mm thick | m | 78.0 | 78.0 | 60.0 | False | None | None | False | None | False | 4680.0 | 0 | 2288143 | 67381 | None | 1.3.2 | Supplying heavy gauge PVC Conduit Pipe . dia . mm thick
with suitable size bends, metal junction boxes adhesive paste etc., by
groove cutting in the wall and fixing by bracing U or J hooks and
cement plastering upto the wall surface and run with 18 SWG GI fish
wire run throughout the conduit wherever necessary.25 mm dia 2 mm thick | m | 79.0 | 79.0 | 20.0 | False | None | None | False | None | False | 1580.0 | 0 | 2288144 | 67381 | None | 1.5.2 | Supplying and fixing PVC/metal conduit Deep junction box 25 mm deep Junction box | Each | 56.0 | 56.0 | 6.0 | False | None | None | False | None | False | 336.0 | 0 | 2288145 | 67381 | None | 1.6.3 | Supplying and flush mounting teak wooden box without front plank,
made of not less than 12 mm thick wood, after due groove cutting,
finishing with necessary cement plastering complete. 10" x 7" x 3" (254 x 178 x 76 mm) | Each | 112.0 | 112.0 | 4.0 | False | None | None | False | None | False | 448.0 | 0 | 2288146 | 67381 | None | 1.6.4 | Supplying and flush mounting teak wooden box without front plank,
made of not less than 12 mm thick wood, after due groove cutting,
finishing with necessary cement plastering complete.8" x 6" x 3" (203 x 152 x 76 mm) | Each | 86.0 | 86.0 | 2.0 | False | None | None | False | None | False | 172.0 | 0 | 2288147 | 67381 | None | 1.12 | Supplying And Fixing M.S. Rafter Clamp Set made out of M.S.
Flat & 14 mm M.S. rod. | No | 160.0 | 160.0 | 6.0 | False | None | None | False | None | False | 960.0 | 0 | 2288148 | 67381 | None | 2.1.1 | Supplying and wiring adopting loop system in existing PVC
Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) &
1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated
copper wire (confirming to IS-694: and latest amendments) with
a 6Amps flush type SP control switch shall be fixed on the existing
plastic sheet/ gang box, the other end of the wires shall be terminated
with sufficient loose length in a wood/PVC round block. complete for
each outlet. Short point upto 3Mtr from tapping point to out let via switch | Point | 285.0 | 285.0 | 12.0 | False | None | None | False | None | False | 3420.0 | 0 | 2288149 | 67381 | None | 2.1.2 | Supplying and wiring adopting loop system in existing PVC
Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) &
1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated
copper wire (confirming to IS-694: and latest amendments) with
a 6Amps flush type SP control switch shall be fixed on the existing
plastic sheet/ gang box, the other end of the wires shall be terminated
with sufficient loose length in a wood/PVC round block. complete for
each outlet. Medium point above 3Mtr upto 6Mtr from tapping point to out let via
switch | Point | 394.0 | 394.0 | 8.0 | False | None | None | False | None | False | 3152.0 | 0 | 2288150 | 67381 | None | 2.1.3 | Supplying and wiring adopting loop system in existing PVC
Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) &
1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated
copper wire (confirming to IS-694: and latest amendments) with
a 6Amps flush type SP control switch shall be fixed on the existing
plastic sheet/ gang box, the other end of the wires shall be terminated
with sufficient loose length in a wood/PVC round block. complete for
each outlet. Long point above 6Mtr upto 10Mtr from tapping point to out let via
switch | Point | 570.0 | 570.0 | 6.0 | False | None | None | False | None | False | 3420.0 | 0 | 2288151 | 67381 | None | 2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010 1.5 mm2 | m | 26.0 | 26.0 | 120.0 | False | None | None | False | None | False | 3120.0 | 0 | 2288152 | 67381 | None | 2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010 2.5 mm2 | m | 42.0 | 42.0 | 90.0 | False | None | None | False | None | False | 3780.0 | 0 | 2288153 | 67381 | None | 2.3.4 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010 4.0 mm2 | m | 63.0 | 63.0 | 60.0 | False | None | None | False | None | False | 3780.0 | 0 | 2288154 | 67381 | None | 3.6.1 | Supplying and fixing of modular switch & connected accessories on
existing modular switch plate as per IS 3854 and IS 1293. 6A One Way Switch | Each | 102.0 | 102.0 | 18.0 | False | None | None | False | None | False | 1836.0 | 0 | 2288155 | 67381 | None | 3.6.3 | Supplying and fixing of modular switch & connected accessories on
existing modular switch plate as per IS 3854 and IS 1293. 6A Three Way socket | Each | 171.0 | 171.0 | 6.0 | False | None | None | False | None | False | 1026.0 | 0 | 2288156 | 67381 | None | 3.3.3 | Supplying and fixing surface/flush mounting unbreakable PVC
modular box suitable for mounting modular switch plates with due
groove cutting in Brick/C.C wall, including necessary rawl plugs,
Machine/NF screws etc., complete.4-5 Way | Each | 137.0 | 137.0 | 2.0 | False | None | None | False | None | False | 274.0 | 0 | 2288157 | 67381 | None | 3.4.3 | Supplying and flush mounting powder coated / galvanized metal box
suitable for mounting modular switch plates. The box should be firmly
flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5 Way | Each | 177.0 | 177.0 | 2.0 | False | None | None | False | None | False | 354.0 | 0 | 2288158 | 67381 | None | 3.5.1 | Supplying and fixing superior quality modular switch mounting
polycarbonate plate with necessary supporting back plate with required
nos. of machine screws, bolts nuts etc., complete on the existing
metal/PVC box 1 to 2 Module | Each | 137.0 | 137.0 | 2.0 | False | None | None | False | None | False | 274.0 | 0 | 2288159 | 67381 | None | 3.9 | Supplying and fixing hylum plastic sheet 3mm thick with necessary
nitches for fixing switches, regulators etc., and fixing on existing
wood or metal box using N. F. screws. | Sq CM | 0.35 | 0.35 | 2500.0 | False | None | None | False | None | False | 875.0 | 0 | 2288160 | 67381 | None | 6.3.1 | Supplying capacitor type ceiling fan complete with down rod blades,
shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase
AC supply conforming to ISS-374- 1979 and with double ball bearing
system. 48" Sweep (1200 mm) Regular model | Each | 2984.0 | 2984.0 | 5.0 | False | None | None | False | None | False | 14920.0 | 0 | 2288161 | 67381 | None | 11.3.2 | Supplying of .feet -PVC Batten with integrated LED tube . W
with high quality diffuser with Life of 25000 burning hours & 70%
lumen maintenance with CRI greater than 80. Power Input: 220-240V@
50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years
Warranty against any manufacturing defect working under standard
electrical condition. LED light fitting 1 x 4' - 20/22 W | Each | 690.0 | 690.0 | 7.0 | False | None | None | False | None | False | 4830.0 | 0 | 2288162 | 67381 | None | 13.7.1 | Fixing all types and all capacities of fluorescent /false ceiling / spot
light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders
using 23/0.0076" twin twisted PVC insulated wires, required Nos of
round blocks and clamps. On wall/ ceiling / Rafter / Girders | Each | 122.0 | 122.0 | 7.0 | False | None | None | False | None | False | 854.0 | 0 | 2288163 | 67381 | None | 13.10 | Fixing a ceiling / Wall mounting fan of all capacities and all types to
the existing 'S'' hook with fan regulator to the existing board together
with supplying and fixing 5 A. ceiling rose, necessary length of
23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. | Each | 171.0 | 171.0 | 6.0 | False | None | None | False | None | False | 1026.0 | 0 | 2288164 | 67381 | None | 5.19.12 | Supplying and fixing regular MCB distribution boards on wall/ood
board / flush mounting using required clamps, bolts, nuts etc., with
provision for fixing suitable type capacity MCB's single phase/3
phase/single door with powder coated painting Made out of 14 SWG
MS enclosure. III - Double Door 6 Way TP & N | Each | 4940.0 | 4940.0 | 1.0 | False | None | None | False | None | False | 4940.0 | 0 | 2288165 | 67381 | None | 5.18.4 | Supplying & fixing miniature circuit breakers on existing MCB
distribution boards using necessary fixing materials and 'C' Type
curve, indicator ON/OFF, energy cross-3 with Short circuit breaking
capacity of 10K and complete wiring as required confirming to IEC
60898. 6-32 A DP | Each | 739.0 | 739.0 | 1.0 | False | None | None | False | None | False | 739.0 | 0 | 2288166 | 67381 | None | 5.38 | Supplying and fixing of LED type panel board indicating lamp
with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C | Each | 515.0 | 515.0 | 2.0 | False | None | None | False | None | False | 1030.0 | 0 |
|
|
---|