tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1706646918000 | 0 | None | None | Buildings | Construction of One Class Room to Govt Primary School at Maradagi (SA) Village in Jewargi Taluka Dist. Kalaburagi. Under KKRDB Micro for the year 2023-24. | 1295782.28 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2343571 | 69326 | None | PWD DSR 2023-24 IT.NO 1.5.1 | Earth work excavation by manual means for drains,canals, waste weir draft,
approach channels, key trench, foundation of Bridges and such similar works,
as per drawing and technical specifications, including setting out, shoring,
strutting, barricading, caution lights, excavated surface leveled and sides neatly
dressed disposing off or leveling the excavated stuff or sorting & stacking the
selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost
of labour, tools, usage & other appurtenances required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depth | Cum | 313.95 | 313.95 | 49.57 | False | None | None | False | None | False | 15562.5015 | 0 | 2343572 | 69326 | None | PWD DSR 2023-24 IT.NO 2.1.4 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6527.85 | 6527.85 | 11.9 | False | None | None | False | None | False | 77681.415 | 0 | 2343573 | 69326 | None | PWD DSR 2023-24 IT.NO 2.4.2 | Providing and laying in position Cement Concrete for all Sub structures of
building, Irrigation works, Sub structure works of bridges, Drain works &
other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt
crushed graded coarse aggregates and fine aggregates as per relevant IS
Codes machine mixed with super plasticisers, laid in layers, well compacted
using needle vibrators, providing weep holes wherever necessary, including
all lead & lifts, cost of all materials of quality, confirming to the requirements
of relevant IS codes, labour, Usage charges of machinery, curing and all other
appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6639.15 | 6639.15 | 26.02 | False | None | None | False | None | False | 172750.683 | 0 | 2343574 | 69326 | None | Vol-I S R Sl no. 1(b) Page No. 111 | Addendum I-Percentage Additionalities for Formwork,
Centering & Scaffolding for Foundation upto Plinth All other types add 3 Percent | Cum | 199.17 | 199.17 | 5.83 | False | None | None | False | None | False | 1161.1611 | 0 | 2343575 | 69326 | None | Vol-I S R Sl no. 9 Page No. 111 | Addendum I-Percentage Additionalities for Formwork,
Centering & Scaffolding for RCC Columns / Shaft (Slip Centering) add 70 Percent | Cum | 4647.4 | 4647.4 | 3.74 | False | None | None | False | None | False | 17381.276 | 0 | 2343576 | 69326 | None | Vol-I S R Sl no. 2 Page No. 111 | Addendum I-Percentage Additionalities for Formwork,
Centering & Scaffolding for Plinth Beams of Buildings add 50 Percent | Cum | 3319.57 | 3319.57 | 2.51 | False | None | None | False | None | False | 8332.1207 | 0 | 2343577 | 69326 | None | Vol-I S R No. 14 Page No. 112 | Addendum I-Percentage Additionalities for Formwork,
Centering & Scaffolding for RCC Beams, Lintels & Troughs of Aqueducts add 60 Percent | Cum | 3983.49 | 3983.49 | 5.44 | False | None | None | False | None | False | 21670.1856 | 0 | 2343578 | 69326 | None | Vol-I SR Sl no. 15 Page No. 112 | Addendum I-Percentage Additionalities for Formwork,
Centering & Scaffolding for RCC Roof Slabs add 50 Percent | Cum | 3319.57 | 3319.57 | 8.36 | False | None | None | False | None | False | 27751.6052 | 0 | 2343579 | 69326 | None | Vol-I S R Sl no. 19 Page No.112 | Addendum I-Percentage Additionalities for Formwork,
Centering & Scaffolding for Chejjas, Canopy & Other Architectural projections of
minor sections add 45 Percent | Cum | 2987.62 | 2987.62 | 0.14 | False | None | None | False | None | False | 418.2668 | 0 | 2343580 | 69326 | None | PWD DSR 2023-24 IT.NO 5.1.1 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement: 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 5891.55 | 5891.55 | 16.1 | False | None | None | False | None | False | 94853.955 | 0 | 2343581 | 69326 | None | PWD DSR 2023-24 IT.NO 5.4 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6708.5 | 6708.5 | 12.17 | False | None | None | False | None | False | 81642.445 | 0 | 2343582 | 69326 | None | PWD DSR 2023-24 IT.NO 2.11 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. | t | 93929.9 | 93929.9 | 2.65 | False | None | None | False | None | False | 248914.235 | 0 | 2343583 | 69326 | None | PWD DSR 2023-24 IT.NO 1.8 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. | Cum | 497.7 | 497.7 | 42.05 | False | None | None | False | None | False | 20928.285 | 0 | 2343584 | 69326 | None | PWD DSR 2023-24 IT.NO 6.7 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 8621.55 | 8621.55 | 17.19 | False | None | None | False | None | False | 148204.4445 | 0 | 2343585 | 69326 | None | PWD DSR 2023-24 IT.NO 12.13.1 | Providing Salwood frames of doors, windows, clerestory windows,
ventilators and other frames, wrought, framed or assembled including
making plaster groves (excluding cost of cement concrete and side clamps),
but including cost of materials, labour, usage charges complete as per
specifications. | Cum | 103755.75 | 103755.75 | 0.32 | False | None | None | False | None | False | 33201.84 | 0 | 2343586 | 69326 | None | PWD DSR 2021-22 IT.NO 11.34A | Providing and fixing M.S. grills of required pattern in frames of windows
etc. with M.S. flats, square or round bars etc. including priming coat with
approved steel primer all complete. Fixed to steel windows by welding | Kg | 176.4 | 176.4 | 95.04 | False | None | None | False | None | False | 16765.056 | 0 | 2343587 | 69326 | None | PWD DSR 2023-24 IT.NO 8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 52.5 | 52.5 | 9.72 | False | None | None | False | None | False | 510.3 | 0 | 2343588 | 69326 | None | PWD DSR 2023-24 IT.NO 8.40 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 120.75 | 120.75 | 9.72 | False | None | None | False | None | False | 1173.69 | 0 | 2343589 | 69326 | None | PWD DSR 2023-24 IT.NO 12.51 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. | No | 1066.8 | 1066.8 | 1.0 | False | None | None | False | None | False | 1066.8 | 0 | 2343590 | 69326 | None | PWD DSR 2023-24 IT.NO 12.52 | Fixing of window frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debries with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. | No | 811.65 | 811.65 | 3.0 | False | None | None | False | None | False | 2434.95 | 0 | 2343591 | 69326 | None | PWD DSR 2023-24 IT.NO 8.1.2 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement:
6 fine sand) including rounding off corners wherever required smooth
rendering, providing and removing scaffolding, including cost of materials,
labour, curing complete as per specifications and as per directions of
Engineer-in-charge. | Sqm | 253.05 | 253.05 | 51.66 | False | None | None | False | None | False | 13072.563 | 0 | 2343592 | 69326 | None | PWD DSR 2023-24 IT.NO 8.3.1 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to
brick/stone masonry including rounding off corners wherever required
smooth rendering, providing and removing scaffolding, including cost of
materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 371.7 | 371.7 | 27.4 | False | None | None | False | None | False | 10184.58 | 0 | 2343593 | 69326 | None | PWD DSR 2023-24 IT.NO 9.34 | Flooring with 25mm thick polished tandur blue stone slabs using cement
mortar 1:6, 25mm thick over existing cement concrete bed or top of roof
laid to line and level and jointed with cement slurry mixed with pigment
to match the shade of the slab, , including cost of materials, labour, curing,
polishing complete as per specifications. | Sqm | 1622.25 | 1622.25 | 60.37 | False | None | None | False | None | False | 97935.2325 | 0 | 2343594 | 69326 | None | PWD DSR 2023-24 IT.NO 12.21 | Providing and fixing in position fully panelled Matti/Nandi wood shutters for doors with , stiles and rails of 30mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures) | Sqm | 6029.1 | 6029.1 | 2.52 | False | None | None | False | None | False | 15193.332 | 0 | 2343595 | 69326 | None | PWD DSR 2023-24 IT.NO 12.32 | Providing and fixing in position Mathi / Nandi wood fully panelled shutters for windows with stiles and rails of 25mm. thick, 75mm wide in two halves with panels of 20mm thick including cost of materials, labour charges, usage charges complete as per specifications. (excluding cost of fixtures) | Sqm | 6134.1 | 6134.1 | 4.32 | False | None | None | False | None | False | 26499.312 | 0 | 2343596 | 69326 | None | PWD DSR 2023-24 IT.NO 8.25 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 143.85 | 143.85 | 154.12 | False | None | None | False | None | False | 22170.162 | 0 | 2343597 | 69326 | None | PWD DSR 2023-24 IT.NO 8.28 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 93.45 | 93.45 | 117.77 | False | None | None | False | None | False | 11005.6065 | 0 | 2343598 | 69326 | None | PWD DSR 2023-24 IT.NO 8.34.1 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 55.65 | 55.65 | 15.39 | False | None | None | False | None | False | 856.4535 | 0 | 2343599 | 69326 | None | PWD DSR 2023-24 IT.NO 8.33.2 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 144.9 | 144.9 | 17.82 | False | None | None | False | None | False | 2582.118 | 0 | 2343600 | 69326 | None | Vol-II I No. 8.9 Page No. 42 | Providing 18 mm cement plaster in two coats under layer 12 mm thick
cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a
top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement
: 3 coarse sand) finished rough with sponge to brick masonry including
rounding off corners wherever required smooth rendering, providing and
removing scaffolding, including cost of materials, labour, curing complete
as per specifications and as per directions of Engineer-in-charge. | Sqm | 404.25 | 404.25 | 183.13 | False | None | None | False | None | False | 74030.3025 | 0 | 2343601 | 69326 | None | Vol-II I No. 8.51 Page No. 50 | Providing and applying white cement based putty of average thickness
1 mm, of approved brand and manufacturer, over the plastered
wall surface to prepare the surface even and smooth complete as per
specifications and as per directions of Engineer in charge. | Sqm | 105.0 | 105.0 | 120.88 | False | None | None | False | None | False | 12692.4 | 0 | 2343602 | 69326 | None | Vol-II I No. 11.28 Page no. 85 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow
tubes, channels, plates etc., including welding, grinding, buffing, polishing
and making curvature (wherever required) and fitting the same with
necessary stainless steel nuts and bolts complete, i/c fixing the railing
with necessary accessories & stainless steel dash fasteners, stainless
steel bolts etc., of required size, on the top of the floor or the side of waist
slab with suitable arrangement as per approval of Engineer-in- charge,
(for payment purpose only weight of stainless steel members shall be
considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
including cost of materials, labour, usage charges of machinery complete
as per specifications and as per directions of the Engineer-in-Charge. | Kg | 593.25 | 593.25 | 16.0 | False | None | None | False | None | False | 9492.0 | 0 | 2343603 | 69326 | None | Vol-III I No. 8.7 Page no. 65 | Providing and erecting direction and place identification retroreflectorised sign as per IRC:67:2022 made of high intensity
grade sheeting vide clause 801.3, fixed over aluminium
sheeting, 2 mm thick or Aluminium composite material sheet
with overall thickness of 4mm with area not exceeding 0.9
m2
fixed over back support frame of min 35 x 35 x 3mm angle
mounted on a mild steel circular pipe 65 NB, firmly fixed to the
ground by means of properly designed foundation with M25
grade cement concrete 45 x 45 x 60 cm, 60 cm below ground
level as per approved drawing | Sqm | 9460.5 | 9460.5 | 0.81 | False | None | None | False | None | False | 7663.005 | 0 |
| 1706646918000 | 0 | None | None | Buildings | ELECTRICAL WORK | 91127.0 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2343604 | 69327 | None | 1.2.2 | Supplying heavy gauge PVC conduit pipe . mm dia.mm thick
confirming to IS 2509 with suitable size bends, metal/PVC Junction
boxes, adhesive paste etc., and running before concreting the slab. The
conduit should be tied to the reinforcement rods by using binding
wires and unused ways of junction boxes and pipe ends should be
covered using PVC end enclosures, run with 18SWG GI fish wire
wherever necessary 25 mm dia 2 mm thick | m | 78.0 | 78.0 | 140.0 | False | None | None | False | None | False | 10920.0 | 0 | 2343605 | 69327 | None | 1.3.2 | Supplying heavy gauge PVC Conduit Pipe . dia . mm thick
with suitable size bends, metal junction boxes adhesive paste etc., by
groove cutting in the wall and fixing by bracing U or J hooks and
cement plastering upto the wall surface and run with 18 SWG GI fish
wire run throughout the conduit wherever necessary. 25 mm dia 2 mm thick | m | 79.0 | 79.0 | 140.0 | False | None | None | False | None | False | 11060.0 | 0 | 2343606 | 69327 | None | 1.5.1 | Supplying and fixing PVC/metal conduit Deep junction box 19/20 mm deep Junction box | Each | 56.0 | 56.0 | 10.0 | False | None | None | False | None | False | 560.0 | 0 | 2343607 | 69327 | None | 1.6.3 | Supplying and flush mounting teak wooden box without front plank,
made of not less than 12 mm thick wood, after due groove cutting,
finishing with necessary cement plastering complete. 10" x 7" x 3" (254 x 178 x 76 mm) | Each | 112.0 | 112.0 | 3.0 | False | None | None | False | None | False | 336.0 | 0 | 2343608 | 69327 | None | 1.13 | Supplying And Fixing Metal Fan Box with Round Hook. | No | 117.0 | 117.0 | 3.0 | False | None | None | False | None | False | 351.0 | 0 | 2343609 | 69327 | None | 2.1.1 | Supplying and wiring adopting loop system in existing PVC
Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) &
1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated
copper wire (confirming to IS-694: and latest amendments) with
a 6Amps flush type SP control switch shall be fixed on the existing
plastic sheet/ gang box, the other end of the wires shall be terminated
with sufficient loose length in a wood/PVC round block. complete for
each outlet. Short point upto 3Mtr from tapping point to out let via switch | Point | 285.0 | 285.0 | 7.0 | False | None | None | False | None | False | 1995.0 | 0 | 2343610 | 69327 | None | 2.1.2 | Supplying and wiring adopting loop system in existing PVC
Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) &
1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated
copper wire (confirming to IS-694: and latest amendments) with
a 6Amps flush type SP control switch shall be fixed on the existing
plastic sheet/ gang box, the other end of the wires shall be terminated
with sufficient loose length in a wood/PVC round block. complete for
each outlet Medium point above 3Mtr upto 6Mtr from tapping point to out let via
switch | Point | 394.0 | 394.0 | 7.0 | False | None | None | False | None | False | 2758.0 | 0 | 2343611 | 69327 | None | 2.1.3 | Supplying and wiring adopting loop system in existing PVC
Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) &
1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated
copper wire (confirming to IS-694: and latest amendments) with
a 6Amps flush type SP control switch shall be fixed on the existing
plastic sheet/ gang box, the other end of the wires shall be terminated
with sufficient loose length in a wood/PVC round block. complete for
each outlet Long point above 6Mtr upto 10Mtr from tapping point to out let via
switch | Point | 570.0 | 570.0 | 7.0 | False | None | None | False | None | False | 3990.0 | 0 | 2343612 | 69327 | None | 2.5.2 | Supplying and drawing Flexible Multicore Cable manufactured with
electrolytic grade flexible copper with low conductor confirming to
IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for
working voltage upto 1100 Volts as per IS-694:1990 3C x 1.5 mm2 | m | 72.0 | 72.0 | 140.0 | False | None | None | False | None | False | 10080.0 | 0 | 2343613 | 69327 | None | 2.5.3 | Supplying and drawing Flexible Multicore Cable manufactured with
electrolytic grade flexible copper with low conductor confirming to
IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for
working voltage upto 1100 Volts as per IS-694:19904C x 1.5 mm2 | m | 94.0 | 94.0 | 140.0 | False | None | None | False | None | False | 13160.0 | 0 | 2343614 | 69327 | None | 3.1.1 | Supplying 6A flush type socket and 6 A flush type SP switch either
surface/flush mounting in existing gang box or in 4mm thick plastic
sheet and fixing over a flush mounted wooden box and wiring using
necessary capacity wires as required as per IS 1293 and IS 3854 6A 2 Way | Each | 128.0 | 128.0 | 5.0 | False | None | None | False | None | False | 640.0 | 0 | 2343615 | 69327 | None | 3.14.2 | Supplying And fixing/replacing of 6/16/32A electrical
accessories on existing switch board. 6A Two Way Switch | No | 70.0 | 70.0 | 5.0 | False | None | None | False | None | False | 350.0 | 0 | 2343616 | 69327 | None | 3.5.2 | Supplying and fixing superior quality modular switch mounting
polycarbonate plate with necessary supporting back plate with required
nos. of machine screws, bolts nuts etc., complete on the existing
metal/PVC box. 3 Module | Each | 161.0 | 161.0 | 15.0 | False | None | None | False | None | False | 2415.0 | 0 | 2343617 | 69327 | None | 3.5.4 | Supplying and fixing superior quality modular switch mounting
polycarbonate plate with necessary supporting back plate with required
nos. of machine screws, bolts nuts etc., complete on the existing
metal/PVC box. 6 Module | Each | 234.0 | 234.0 | 15.0 | False | None | None | False | None | False | 3510.0 | 0 | 2343618 | 69327 | None | 3.9 | Supplying and fixing hylum plastic sheet 3mm thick with necessary
nitches for fixing switches, regulators etc., and fixing on existing
wood or metal box using N. F. screws. | Sq CM | 0.35 | 0.35 | 20000.0 | False | None | None | False | None | False | 7000.0 | 0 | 2343619 | 69327 | None | 6.32 | Supplying capacitor type ceiling fan complete with down rod blades,
shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase
AC supply conforming to ISS-374- 1979 and with double ball bearing
system.56" Sweep (1400 mm) Regular model
| Each | 3031.0 | 3031.0 | 3.0 | False | None | None | False | None | False | 9093.0 | 0 | 2343620 | 69327 | None | 13.7.1 | Fixing all types and all capacities of fluorescent /false ceiling / spot
light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders
using 23/0.0076" twin twisted PVC insulated wires, required Nos of
round blocks and clamps. On wall/ ceiling / Rafter / Girders | Each | 122.0 | 122.0 | 10.0 | False | None | None | False | None | False | 1220.0 | 0 | 2343621 | 69327 | None | 13.11 | Fixing a ceiling /wall mounting fan of all capacities and all types,
with necessary clamps and 'S' hook made out of 15mm dia MS rod,
with 5 A. ceiling rose of approved quality with necessary length of
23/0.0076 inch PVC insulated twin twisted wire of approved quality,
mounted on a suitable size wooden board and wired. | Each | 315.0 | 315.0 | 3.0 | False | None | None | False | None | False | 945.0 | 0 | 2343622 | 69327 | None | 5.17.1 | Supplying and fixing regular MCCB distribution Panel confirming to
IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum
IP43 protection provided with Polyurethane (PUR) gasket, with
suitable earthing system, on wall/wood board/flush mounting using
required cl A , bolts, nuts, etc., with provision for fixing of suitable
type capacity MCCB's as an incomer for 3 phase Double door with
necessary bus bar completely wired to use on 440V 3phase 4 wire
powder coated painting etc., complete with a provision for fixing of
single/three phase suitable capacity MCB's as outgoings confirming to
IS/IEC 60898 - 2. 4 Way | Each | 10329.0 | 10329.0 | 1.0 | False | None | None | False | None | False | 10329.0 | 0 | 2343623 | 69327 | None | 5.18.1 | Supplying & fixing miniature circuit breakers on existing MCB
distribution boards using necessary fixing materials and 'C' Type
curve, indicator ON/OFF, energy cross-3 with Short circuit breaking
capacity of 10K and complete wiring as required confirming to IEC
60898.6-32 A SP | Each | 415.0 | 415.0 | 1.0 | False | None | None | False | None | False | 415.0 | 0 |
|
|
---|