tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1706682498000 | 1 | None | None | Buildings | UPGRADATION OF BASIC AMENITIES TO TLH & STAFF QTRS AT SINDHANUR IN RAICHUR DIST (HOSPITAL RENOVATION) | 18591189.14 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2349202 | 69465 | None | 001 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground to the appropriate disposal area as per direction of Engineer-in-charge. ---- etc., complete with all lead | Sqm | 45.84 | 45.84 | 800.0 | False | None | None | False | None | False | 36672.0 | 0 | 2349203 | 69465 | None | 002 | Providing and fixing plaster mesh 150mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per Sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment ) - -etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc., complete with all lead | Sqm | 47.08 | 47.08 | 1000.0 | False | None | None | False | None | False | 47080.0 | 0 | 2349204 | 69465 | None | 003 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement:6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per Specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead | Sqm | 298.6 | 298.6 | 1000.0 | False | None | None | False | None | False | 298600.0 | 0 | 2349205 | 69465 | None | 004 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. - -etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc., complete with all lead | Sqm | 123.9 | 123.9 | 1200.0 | False | None | None | False | None | False | 148680.0 | 0 | 2349206 | 69465 | None | 005 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead | Sqm | 157.35 | 157.35 | 1200.0 | False | None | None | False | None | False | 188820.0 | 0 | 2349207 | 69465 | None | 006 | Demolishing cement concrete manually/ by mechanical means including disposal of material to the appropriate disposal area as per direction of Engineer-in-charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) 19.2.2
FIRST FLOOR ---- etc., complete with all lead | Sqm | 1287.68 | 1287.68 | 58.0 | False | None | None | False | None | False | 74685.44 | 0 | 2349208 | 69465 | None | 007 | Demolishing cement concrete manually/ by mechanical means including disposal of material to the appropriate disposal area as per direction of Engineer-in-charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) 19.2.2 GROUND FLOOR ---- etc., complete with all lead | Sqm | 1274.93 | 1274.93 | 10.8 | False | None | None | False | None | False | 13769.244 | 0 | 2349209 | 69465 | None | 008 | Dismantling weather proof course and removing and conveying the debris to a distance to the appropriate disposal area as per direction of Engineer-in-charge. FIRST FLOOR ---- etc., complete with all lead | Sqm | 720.8 | 720.8 | 494.24 | False | None | None | False | None | False | 356248.192 | 0 | 2349210 | 69465 | None | 009 | Dismantling weather proof course and removing and conveying the debris to a distance to the appropriate disposal area as per direction of Engineer-in-charge.
GROUND FLOOR ---- etc., complete with all lead | Sqm | 713.66 | 713.66 | 16.2 | False | None | None | False | None | False | 11561.292 | 0 | 2349211 | 69465 | None | 010 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material to the appropriate disposal area as per direction of Engineer-in-charge. For thickness of tiles 10 mm to 25 mm
FIRST FLOOR ---- etc., complete with all lead | Sqm | 60.06 | 60.06 | 902.26 | False | None | None | False | None | False | 54189.7356 | 0 | 2349212 | 69465 | None | 011 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material to the appropriate disposal area as per direction of Engineer-in-charge. For thickness of tiles 10 mm to 25 mm
GROUND FLOOR ---- etc., complete with all lead | Sqm | 59.47 | 59.47 | 251.4 | False | None | None | False | None | False | 14950.758 | 0 | 2349213 | 69465 | None | 012 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking to the appropriate disposal area as per direction of Engineer- in-charge.
Of area 3 m² and below ---- etc., complete with all lead | Sqm | 297.36 | 297.36 | 84.3 | False | None | None | False | None | False | 25067.448 | 0 | 2349214 | 69465 | None | 013 | Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis) - -etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. FIRST FLOOR ---- etc., complete with all lead | Sqm | 769.61 | 769.61 | 874.96 | False | None | None | False | None | False | 673377.9656 | 0 | 2349215 | 69465 | None | 014 | Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis) - -etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. GROUND FLOOR ---- etc., complete with all lead | Sqm | 761.99 | 761.99 | 158.4 | False | None | None | False | None | False | 120699.216 | 0 | 2349216 | 69465 | None | 015 | Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. - -etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work.
FIRST FLOOR ---- etc., complete with all lead | Cum | 2524.06 | 2524.06 | 174.0 | False | None | None | False | None | False | 439186.44 | 0 | 2349217 | 69465 | None | 016 | Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. - -etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work.
GROUND FLOOR ---- etc., complete with all lead | Cum | 2499.06 | 2499.06 | 32.4 | False | None | None | False | None | False | 80969.544 | 0 | 2349218 | 69465 | None | 017 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The Granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. (Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates) GROUND FLOOR ---- etc., complete with all lead | Cum | 7735.08 | 7735.08 | 23.3 | False | None | None | False | None | False | 180227.364 | 0 | 2349219 | 69465 | None | 018 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The Granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. (Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates) FIRST FLOOR ---- etc., complete with all lead | Cum | 7812.43 | 7812.43 | 268.89 | False | None | None | False | None | False | 2100684.3027 | 0 | 2349220 | 69465 | None | 019 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. - -etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work.
GROUND FLOOR ---- etc., complete with all lead | Sqm | 1012.26 | 1012.26 | 432.59 | False | None | None | False | None | False | 437893.5534 | 0 | 2349221 | 69465 | None | 020 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. - -etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work.
FIRST FLOOR ---- etc., complete with all lead | Sqm | 1022.39 | 1022.39 | 2005.63 | False | None | None | False | None | False | 2050536.0557 | 0 | 2349222 | 69465 | None | 021 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. - -etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work.
FIRST FLOOR ---- etc., complete with all lead | Sqm | 1346.5 | 1346.5 | 580.0 | False | None | None | False | None | False | 780970.0 | 0 | 2349223 | 69465 | None | 022 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. - -etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work.
GROUND FLOOR ---- etc., complete with all lead | Sqm | 1333.16 | 1333.16 | 108.0 | False | None | None | False | None | False | 143981.28 | 0 | 2349224 | 69465 | None | 023 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. - -etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work.
FIRST FLOOR ---- etc., complete with all lead | Sqm | 1741.94 | 1741.94 | 342.26 | False | None | None | False | None | False | 596196.3844 | 0 | 2349225 | 69465 | None | 024 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. - -etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work.
GROUND FLOOR ---- etc., complete with all lead | Sqm | 1724.69 | 1724.69 | 97.8 | False | None | None | False | None | False | 168674.682 | 0 | 2349226 | 69465 | None | 025 | Fixing glazed/ Ceramic/ Vitrified floor tiles with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477, in average 3mm thickness. - -etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work.
GROUND FLOOR ---- etc., complete with all lead | Sqm | 437.37 | 437.37 | 205.8 | False | None | None | False | None | False | 90010.746 | 0 | 2349227 | 69465 | None | 026 | Fixing glazed/ Ceramic/ Vitrified floor tiles with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477, in average 3mm thickness. - -etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work.
FIRST FLOOR ---- etc., complete with all lead | Sqm | 441.74 | 441.74 | 922.26 | False | None | None | False | None | False | 407399.1324 | 0 | 2349228 | 69465 | None | 027 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. - -etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work.
FIRST FLOOR ---- etc., complete with all lead | Sqm | 369.15 | 369.15 | 342.26 | False | None | None | False | None | False | 126345.279 | 0 | 2349229 | 69465 | None | 028 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. - -etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work.
GROUND FLOOR ---- etc., complete with all lead | Sqm | 365.51 | 365.51 | 97.8 | False | None | None | False | None | False | 35746.878 | 0 | 2349230 | 69465 | None | 029 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding - -etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work.
---- etc., complete with all lead | Kgs | 208.15 | 208.15 | 345.6 | False | None | None | False | None | False | 71936.64 | 0 | 2349231 | 69465 | None | 030 | Providing & fixing fiber glass reinforced plastic (FRP) Door frame of cross section 90mm x 45mm having single rebate of 32mm x 15mm to recieve shutter of 30mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyster resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The fram,e shall be covered with fiber glass form all sides. MS stay shall be provided at the bottom to steady the frame. - -etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work.
---- etc., complete with all lead | Mtr | 804.64 | 804.64 | 148.5 | False | None | None | False | None | False | 119489.04 | 0 | 2349232 | 69465 | None | 031 | Providing & fixing to existing door frames, 30mm thick Glass fibre reinforced plastic (FRP) panelled door shutter of required colour and approved brand and manufacture made with fire retardant grade unsaturated polyster resin, moulded to 3mm thick FRP Laminate for forming hollow railsand styles with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings cast monolithically with 5mm thick FRP Laminate for panels conforming to IS 14856 Including fixing to frames - -etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work.
---- etc., complete with all lead | Sqm | 4009.45 | 4009.45 | 47.25 | False | None | None | False | None | False | 189446.5125 | 0 | 2349233 | 69465 | None | 032 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. - -etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work.
GROUND FLOOR ---- etc., complete with all lead | Sqm | 438.61 | 438.61 | 505.0 | False | None | None | False | None | False | 221498.05 | 0 | 2349234 | 69465 | None | 033 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
GROUND FLOOR ---- etc., complete with all lead | Sqm | 193.28 | 193.28 | 405.0 | False | None | None | False | None | False | 78278.4 | 0 | 2349235 | 69465 | None | 034 | Providing & fixing of PVC pipes of 6 Kg/cm2 for 110mm(1.894)
---- etc., complete with all lead | Rmtr | 624.46 | 624.46 | 283.75 | False | None | None | False | None | False | 177190.525 | 0 | 2349236 | 69465 | None | 035 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm 2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) - -etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. FIRST FLOOR ---- etc., complete with all lead | Sqm | 8426.86 | 8426.86 | 146.15 | False | None | None | False | None | False | 1231585.589 | 0 | 2349237 | 69465 | None | 036 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) - -etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work.
FIRST FLOOR ---- etc., complete with all lead | Sqm | 7156.7 | 7156.7 | 6.48 | False | None | None | False | None | False | 46375.416 | 0 | 2349238 | 69465 | None | 037 | Providing & Fixing Mosquito mesh shutters made out of Stainless Steel mosquito proof mesh with 95% & above visibility which is fixed to the powder coated aluminium frame 20mm thick of approved shade. The work including fixing the shutters with necessary accessories, to complete as per specification including the labour charges for fixing the shutter to the existing frames. FIRST FLOOR ---- etc., complete with all lead | Sqm | 3593.1 | 3593.1 | 286.29 | False | None | None | False | None | False | 1028668.599 | 0 | 2349239 | 69465 | None | 038 | Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. (In all kinds of soils Depth upto 1.5 m) ---- etc., complete with all lead | Cum | 299.84 | 299.84 | 198.6 | False | None | None | False | None | False | 59548.224 | 0 | 2349240 | 69465 | None | 039 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete with all lead | Cum | 536.49 | 536.49 | 198.6 | False | None | None | False | None | False | 106546.914 | 0 | 2349241 | 69465 | None | 040 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :One coats on old work as per specifications and as per directions of Engineer in charge.
GROUND FLOOR ---- etc., complete with all lead | Sqm | 94.16 | 94.16 | 371.59 | False | None | None | False | None | False | 34988.9144 | 0 | 2349242 | 69465 | None | 041 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :One coats on old work as per specifications and as per directions of Engineer in charge.
FIRST FLOOR ---- etc., complete with all lead | Sqm | 95.11 | 95.11 | 293.85 | False | None | None | False | None | False | 27948.0735 | 0 | 2349243 | 69465 | None | 042 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-inCharge. ---- etc., complete with all lead | Sqm | 1129.97 | 1129.97 | 15.0 | False | None | None | False | None | False | 16949.55 | 0 | 2349244 | 69465 | None | 043 | Providing and fixing sheet covering over expansion joints with iron screws as per design. Aluminium fluted strips 3.15 mm thick. 200 mm wide
FIRST FLOOR ---- etc., complete with all lead | Rmtr | 907.26 | 907.26 | 50.5 | False | None | None | False | None | False | 45816.63 | 0 | 2349245 | 69465 | None | 043 | Providing & fixing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete as per design drawings (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required as per the direction of Engineer in charge. 7.1.1 0.63 mm thick with zinc coating not less than 275 g/ m²
GROUND FLOOR ---- etc., complete with all lead | Sqm | 1099.97 | 1099.97 | 105.0 | False | None | None | False | None | False | 115496.85 | 0 | 2349246 | 69465 | None | 045 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. - - etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.
GROUND FLOOR ---- etc., complete with all lead | Kgs | 183.95 | 183.95 | 729.0 | False | None | None | False | None | False | 134099.55 | 0 | 2349247 | 69465 | None | 046 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap
beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-incharge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion : Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) including cost of materials, labour, usage charges of machinery
complete as per specifications. FIRST FLOOR ---- etc., complete with all lead | Kgs | 565.63 | 565.63 | 336.4 | False | None | None | False | None | False | 190277.932 | 0 | 2349248 | 69465 | None | 047 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates. Including FormWork
GROUND FLOOR ---- etc., complete with all lead | Cum | 7420.37 | 7420.37 | 156.42 | False | None | None | False | None | False | 1160694.2754 | 0 | 2349249 | 69465 | None | 048 | KSRB 14.6-1: Providing and laying heavy duty cobble stones 60mm thick interlock pavers, using cement and course sand for manufacture of blocks of approved size, shape and colour with a minimum compressive strength of 281 kg per sqm over 50mm thick sand bed (average thickness ) and compacting with plate vibrator having 3 tons compaction force thereby forcing part of sand underneath to come up in between joints, final compaction of paver surface joints into its final level, including cost of materials, labour and HOM of machineries complete as per specifications. Specification No. KBS
GROUND FLOOR ---- etc., complete with all lead | Sqm | 1286.08 | 1286.08 | 1061.24 | False | None | None | False | None | False | 1364839.5392 | 0 | 2349250 | 69465 | None | 049 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.
---- etc., complete with all lead | Cum | 9983.59 | 9983.59 | 20.0 | False | None | None | False | None | False | 199671.8 | 0 | 2349251 | 69465 | None | 050 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial - -etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work.
FIRST FLOOR ---- etc., complete with all lead | Sqm | 3760.42 | 3760.42 | 5.76 | False | None | None | False | None | False | 21660.0192 | 0 | 2349252 | 69465 | None | 051 | Repairing and fixing shutters (panelled or glazed) to doors, windows,ventilators and cupboards
---- etc., complete with all lead | Sqm | 1208.03 | 1208.03 | 52.5 | False | None | None | False | None | False | 63421.575 | 0 | 2349253 | 69465 | None | 052 | Removing white wash or colour wash by steel brushing and / or scraping, sand papering and preparing wall surface smooth including repairs to scraches including cost of labour, material complete as per specifications.GROUND FLOOR
---- etc., complete with all lead | Sqm | 16.11 | 16.11 | 5232.04 | False | None | None | False | None | False | 84288.1644 | 0 | 2349254 | 69465 | None | 053 | Removing white wash or colour wash by steel brushing and / or scraping, sand papering and preparing wall surface smooth including repairs to scraches including cost of labour, material complete as per specifications.
FIRST FLOOR ---- etc., complete with all lead | Sqm | 16.27 | 16.27 | 3988.53 | False | None | None | False | None | False | 64893.3831 | 0 | 2349255 | 69465 | None | 054 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. One coat as per specifications and as per directions of Engineer in charge.
GROUND FLOOR ---- etc., complete with all lead | Sqm | 90.45 | 90.45 | 5232.04 | False | None | None | False | None | False | 473238.018 | 0 | 2349256 | 69465 | None | 055 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. One coat as per specifications and as per directions of Engineer in charge.
FIRST FLOOR ---- etc., complete with all lead | Sqm | 91.35 | 91.35 | 3988.53 | False | None | None | False | None | False | 364352.2155 | 0 | 2349257 | 69465 | None | 056 | Finishing walls with water proofing cement paint of required shade :Old work (one coats applied @ 2.20 kg/10 m²) over priming coat of primer applied @ 0.80 litrs/10 m² complete including cost of Priming coat including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR ---- etc., complete with all lead | Sqm | 107.79 | 107.79 | 2745.18 | False | None | None | False | None | False | 295902.9522 | 0 | 2349258 | 69465 | None | 057 | Finishing walls with water proofing cement paint of required shade :Old work (one coats applied @ 2.20 kg/10 m²) over priming coat of primer applied @ 0.80 litrs/10 m² complete including cost of Priming coat including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions
of Engineer-in-charge. FIRST FLOOR
---- etc., complete with all lead | Sqm | 108.87 | 108.87 | 2305.76 | False | None | None | False | None | False | 251028.0912 | 0 | 2349259 | 69465 | None | 058 | Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm
GROUND FLOOR ---- etc., complete with all lead | Sqm | 1455.83 | 1455.83 | 68.0 | False | None | None | False | None | False | 98996.44 | 0 | 2349260 | 69465 | None | 059 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of the slab upto 0.50 m2
GROUND FLOOR ---- etc., complete with all lead | Sqm | 4963.43 | 4963.43 | 76.71 | False | None | None | False | None | False | 380744.7153 | 0 | 2349261 | 69465 | None | 060 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.
GROUND FLOOR ---- etc., complete with all lead | Kgs | 700.04 | 700.04 | 240.12 | False | None | None | False | None | False | 168093.6048 | 0 |
| 1706682498000 | 0 | None | None | Buildings | UPGRADATION OF BASIC AMENITIES TO TLH & STAFF QTRS AT SINDHANUR IN RAICHUR DIST (INTERNAL ELECTRICAL WORKS) | 1101975.05 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2349262 | 69466 | None | 2.2.1 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each
outlet. Short point up to 3Mtr from tapping point to out let via switch ---- etc., complete with all lead | Point | 333.29 | 333.29 | 25.0 | False | None | None | False | None | False | 8332.25 | 0 | 2349263 | 69466 | None | 2.2.2 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each
outlet. Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch ---- etc., complete with all lead | Point | 469.58 | 469.58 | 25.0 | False | None | None | False | None | False | 11739.5 | 0 | 2349264 | 69466 | None | 2.2.3 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switch
---- etc., complete with all lead | Point | 687.65 | 687.65 | 30.0 | False | None | None | False | None | False | 20629.5 | 0 | 2349265 | 69466 | None | 3.4.3 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5Way
---- etc., complete with all lead | Each | 219.3 | 219.3 | 5.0 | False | None | None | False | None | False | 1096.5 | 0 | 2349266 | 69466 | None | 3.4.4 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6Way
---- etc., complete with all lead | Each | 272.58 | 272.58 | 2.0 | False | None | None | False | None | False | 545.16 | 0 | 2349267 | 69466 | None | 3.4.5 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way
---- etc., complete with all lead | Each | 323.38 | 323.38 | 5.0 | False | None | None | False | None | False | 1616.9 | 0 | 2349268 | 69466 | None | 3.4.6 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way
---- etc., complete with all lead | Each | 395.24 | 395.24 | 5.0 | False | None | None | False | None | False | 1976.2 | 0 | 2349269 | 69466 | None | 3.5.2 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module
---- etc., complete with all lead | Each | 216.83 | 216.83 | 5.0 | False | None | None | False | None | False | 1084.15 | 0 | 2349270 | 69466 | None | 3.5.3 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module
---- etc., complete with all lead | Each | 289.93 | 289.93 | 2.0 | False | None | None | False | None | False | 579.86 | 0 | 2349271 | 69466 | None | 3.5.4 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module
---- etc., complete with all lead | Each | 351.88 | 351.88 | 5.0 | False | None | None | False | None | False | 1759.4 | 0 | 2349272 | 69466 | None | 3.5.5 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module
---- etc., complete with all lead | Each | 426.22 | 426.22 | 5.0 | False | None | None | False | None | False | 2131.1 | 0 | 2349273 | 69466 | None | 3.6.1 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch
---- etc., complete with all lead | Each | 126.38 | 126.38 | 200.0 | False | None | None | False | None | False | 25276.0 | 0 | 2349274 | 69466 | None | 3.6.3 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket
---- etc., complete with all lead | Each | 211.87 | 211.87 | 25.0 | False | None | None | False | None | False | 5296.75 | 0 | 2349275 | 69466 | None | 3.6.4 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator.
---- etc., complete with all lead | Each | 442.32 | 442.32 | 25.0 | False | None | None | False | None | False | 11058.0 | 0 | 2349276 | 69466 | None | 3.6.9 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switch
---- etc., complete with all lead | Each | 403.91 | 403.91 | 15.0 | False | None | None | False | None | False | 6058.65 | 0 | 2349277 | 69466 | None | 3.6.10 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socket
---- etc., complete with all lead | Each | 292.4 | 292.4 | 15.0 | False | None | None | False | None | False | 4386.0 | 0 | 2349278 | 69466 | None | 3.6.7 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16Amps one way switch
---- etc., complete with all lead | Each | 223.02 | 223.02 | 15.0 | False | None | None | False | None | False | 3345.3 | 0 | 2349279 | 69466 | None | 1.2.1 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 19/20mm dia 2mm thick
---- etc., complete with all lead | Mtr | 81.77 | 81.77 | 200.0 | False | None | None | False | None | False | 16354.0 | 0 | 2349280 | 69466 | None | 1.2.2 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 25mm dia 2mm thick
---- etc., complete with all lead | Mtr | 96.64 | 96.64 | 100.0 | False | None | None | False | None | False | 9664.0 | 0 | 2349281 | 69466 | None | 1.2.3 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 32mm dia 2.5mm thick
---- etc., complete with all lead | Mtr | 127.62 | 127.62 | 50.0 | False | None | None | False | None | False | 6381.0 | 0 | 2349282 | 69466 | None | 2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest
amendments. 1.5 sqmm
---- etc., complete with all lead | Mtr | 32.21 | 32.21 | 2000.0 | False | None | None | False | None | False | 64420.0 | 0 | 2349283 | 69466 | None | 2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest
amendments. 2.5 sqmm
---- etc., complete with all lead | Mtr | 52.04 | 52.04 | 1200.0 | False | None | None | False | None | False | 62448.0 | 0 | 2349284 | 69466 | None | 2.3.4 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest
amendments. 4 sqmm
---- etc., complete with all lead | Mtr | 78.06 | 78.06 | 800.0 | False | None | None | False | None | False | 62448.0 | 0 | 2349285 | 69466 | None | 2.3.5 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest
amendments. 6 sqmm
---- etc., complete with all lead | Mtr | 113.99 | 113.99 | 400.0 | False | None | None | False | None | False | 45596.0 | 0 | 2349286 | 69466 | None | 5.19.11 | Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 4 Way TP & N ---- etc., complete with all lead | Each | 5003.08 | 5003.08 | 1.0 | False | None | None | False | None | False | 5003.08 | 0 | 2349287 | 69466 | None | 5.19.12 | Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 6 Way TP & N
---- etc., complete with all lead | Each | 6120.66 | 6120.66 | 1.0 | False | None | None | False | None | False | 6120.66 | 0 | 2349288 | 69466 | None | 5.19.9 | Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 12 Way SP & N
---- etc., complete with all lead | Each | 2885.63 | 2885.63 | 1.0 | False | None | None | False | None | False | 2885.63 | 0 | 2349289 | 69466 | None | 5.18.1 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SP
---- etc., complete with all lead | Each | 514.19 | 514.19 | 40.0 | False | None | None | False | None | False | 20567.6 | 0 | 2349290 | 69466 | None | 5.18.8 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 40Amps TPN
---- etc., complete with all lead | Each | 3771.52 | 3771.52 | 8.0 | False | None | None | False | None | False | 30172.16 | 0 | 2349291 | 69466 | None | 32.09 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 35 sqmm
---- etc., complete with all lead | Km | 190882.82 | 190882.82 | 0.1 | False | None | None | False | None | False | 19088.282 | 0 | 2349292 | 69466 | None | 32.13 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 70 sqmm
---- etc., complete with all lead | Km | 393892.97 | 393892.97 | 0.1 | False | None | None | False | None | False | 39389.297 | 0 | 2349293 | 69466 | None | 21.06 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as
directed by the departmental staff 35 sqmm to 95 sqmm ---- etc., complete with all lead | Km | 38581.22 | 38581.22 | 0.2 | False | None | None | False | None | False | 7716.244 | 0 | 2349294 | 69466 | None | 6.11.3 | Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 32mm dia
---- etc., complete with all lead | Each | 144.96 | 144.96 | 2.0 | False | None | None | False | None | False | 289.92 | 0 | 2349295 | 69466 | None | 6.11.6 | Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 63mm dia
---- etc., complete with all lead | Each | 480.73 | 480.73 | 2.0 | False | None | None | False | None | False | 961.46 | 0 | 2349296 | 69466 | None | 6.17.8 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 35 sqmm Long Barrel
---- etc., complete with all lead | Each | 39.65 | 39.65 | 2.0 | False | None | None | False | None | False | 79.3 | 0 | 2349297 | 69466 | None | 12.56 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia
---- etc., complete with all lead | Each | 4348.89 | 4348.89 | 8.0 | False | None | None | False | None | False | 34791.12 | 0 | 2349298 | 69466 | None | 12.58.2 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip
---- etc., complete with all lead | Mtr | 101.6 | 101.6 | 50.0 | False | None | None | False | None | False | 5080.0 | 0 | 2349299 | 69466 | None | 11.5.2 | Supply of round/square recess/surface mounted rolling type LED Down light with W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10-12W ---- etc., complete with all lead | Each | 1096.52 | 1096.52 | 30.0 | False | None | None | False | None | False | 32895.6 | 0 | 2349300 | 69466 | None | 11.3.2 | Supplying of feet PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours 70 lumen maintenance with CRI 80. Power Input: 220 240V 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 w ---- etc., complete with all lead | Each | 854.91 | 854.91 | 60.0 | False | None | None | False | None | False | 51294.6 | 0 | 2349301 | 69466 | None | 11.8.2 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr Lumen Maintenance of 70 maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 40watts ---- etc., complete with all lead | No | 4985.74 | 4985.74 | 6.0 | False | None | None | False | None | False | 29914.44 | 0 | 2349302 | 69466 | None | 6.1 | Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.
---- etc., complete with all lead | Each | 1848.59 | 1848.59 | 15.0 | False | None | None | False | None | False | 27728.85 | 0 | 2349303 | 69466 | None | 6.4.1 | Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/19 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power upto 35 W +/- 10 %, Rated current As per IS:374/19, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 6.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/2019 with latest amendment, 2year manufacturer Warranty. (BLDC fans) 48" Sweep 5 Star (1200 mm)
---- etc., complete with all lead | Each | 3316.8 | 3316.8 | 25.0 | False | None | None | False | None | False | 82920.0 | 0 | 2349304 | 69466 | None | 13.7.1 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders
---- etc., complete with all lead | Each | 151.16 | 151.16 | 90.0 | False | None | None | False | None | False | 13604.4 | 0 | 2349305 | 69466 | None | 13.11 | Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size
wooden board and wired.
---- etc., complete with all lead | Each | 390.29 | 390.29 | 25.0 | False | None | None | False | None | False | 9757.25 | 0 | 2349306 | 69466 | None | 13.13 | Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.
---- etc., complete with all lead | Each | 875.97 | 875.97 | 15.0 | False | None | None | False | None | False | 13139.55 | 0 | 2349307 | 69466 | None | 5.42.2 | Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG ---- etc., complete with all lead | Sq CM | 0.53 | 0.53 | 300000.0 | False | None | None | False | None | False | 159000.0 | 0 | 2349308 | 69466 | None | 5.40.1 | Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminum Strips
---- etc., complete with all lead | Mtr | 3054.14 | 3054.14 | 10.0 | False | None | None | False | None | False | 30541.4 | 0 | 2349309 | 69466 | None | 5.41.1 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm
---- etc., complete with all lead | Mtr | 377.9 | 377.9 | 10.0 | False | None | None | False | None | False | 3779.0 | 0 | 2349310 | 69466 | None | 5.15.9 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.FOUR POLE 100Amps 25kA
---- etc., complete with all lead | Each | 10515.39 | 10515.39 | 2.0 | False | None | None | False | None | False | 21030.78 | 0 | 2349311 | 69466 | None | 5.18.9 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN
---- etc., complete with all lead | Each | 3826.03 | 3826.03 | 15.0 | False | None | None | False | None | False | 57390.45 | 0 | 2349312 | 69466 | None | 5.18.4 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps DP
---- etc., complete with all lead | Each | 915.62 | 915.62 | 10.0 | False | None | None | False | None | False | 9156.2 | 0 | 2349313 | 69466 | None | 5.33 | Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy
---- etc., complete with all lead | Each | 11541.29 | 11541.29 | 1.0 | False | None | None | False | None | False | 11541.29 | 0 | 2349314 | 69466 | None | 5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C
---- etc., complete with all lead | Each | 638.09 | 638.09 | 3.0 | False | None | None | False | None | False | 1914.27 | 0 |
| 1706682498000 | 1 | None | None | Buildings | SUMP TANK | 545034.7 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2349315 | 69467 | None | 001 | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer In area of light jungle
---- etc., complete with all lead | Sqm | 22.3 | 22.3 | 35.0 | False | None | None | False | None | False | 780.5 | 0 | 2349316 | 69467 | None | 002 | Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such
simillar works in all kinds of soils, as per drawing and technical specifications including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.(Depth exceeding 1.5m, but not Exceeding 3 m) ---- etc., complete with all lead | Cum | 320.9 | 320.9 | 66.13 | False | None | None | False | None | False | 21221.117 | 0 | 2349317 | 69467 | None | 003 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
---- etc., complete with all lead | Cum | 329.57 | 329.57 | 12.63 | False | None | None | False | None | False | 4162.4691 | 0 | 2349318 | 69467 | None | 004 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates. Including FormWork
---- etc., complete with all lead | Cum | 7420.37 | 7420.37 | 2.93 | False | None | None | False | None | False | 21741.6841 | 0 | 2349319 | 69467 | None | 005 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork
---- etc., complete with all lead | Cum | 8732.83 | 8732.83 | 4.22 | False | None | None | False | None | False | 36852.5426 | 0 | 2349320 | 69467 | None | 006 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork
---- etc., complete with all lead | Cum | 14413.42 | 14413.42 | 6.05 | False | None | None | False | None | False | 87201.191 | 0 | 2349321 | 69467 | None | 007 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork
---- etc., complete with all lead | Cum | 12717.72 | 12717.72 | 4.22 | False | None | None | False | None | False | 53668.7784 | 0 | 2349322 | 69467 | None | 008 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.
---- etc., complete with all lead | Tonne | 110837.22 | 110837.22 | 1.05 | False | None | None | False | None | False | 116379.081 | 0 | 2349323 | 69467 | None | 009 | Providing and Applying two component, water-based food grade epoxy resin coating on inside surface of Potable water tank having anti-algae, antifungal, Non-toxic, hygiene cum damp-proof coating Certified by CFTRI as per 21 CFR 175 300 of US FDA, having mixing Ratio (Base: Hardener: Water) 1:1:1 to be applied @ 0.35 Kg/m2 in 2 coats. Ensure that this coating is applied over the protective plaster, and that Item No. 4 is completed across the entire surface prior to applying the protective plaster. The Waterproofing material shall have Specific Gravity: 1.2, Water vapor permeance: 244.48 g/m2/24 hrs, as per IS 7809/Pt 2/1977, Adhesion strength: 2 N/mm2 as per ASTM D 4541: 02. The finished cost to include surface preparation completely as per specification
---- etc., complete with all lead | Sqm | 2072.85 | 2072.85 | 67.04 | False | None | None | False | None | False | 138963.864 | 0 | 2349324 | 69467 | None | 010 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
---- etc., complete with all lead | Sqm | 459.67 | 459.67 | 134.08 | False | None | None | False | None | False | 61632.5536 | 0 | 2349325 | 69467 | None | 011 | Providing & fixing 455x610 mm cast iron cover with frame weight to be not less 38kgs (weight of cover 23 kgs and weight of frame 15 kgs)and necessary locking arrangements with M.S flats 32x6 mm etc & painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge.
---- etc., complete with all lead | Each | 2430.92 | 2430.92 | 1.0 | False | None | None | False | None | False | 2430.92 | 0 |
| 1706682498000 | 1 | None | None | Buildings | SEPTIC TANK | 813088.61 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2349326 | 69468 | None | 001 | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer In area of light jungle ---- etc., complete with all lead | Sqm | 22.3 | 22.3 | 80.0 | False | None | None | False | None | False | 1784.0 | 0 | 2349327 | 69468 | None | 002 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m
---- etc., complete with all lead | Cum | 126.38 | 126.38 | 224.0 | False | None | None | False | None | False | 28309.12 | 0 | 2349328 | 69468 | None | 003 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
---- etc., complete with all lead | Cum | 329.57 | 329.57 | 131.6 | False | None | None | False | None | False | 43371.412 | 0 | 2349329 | 69468 | None | 004 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates ---- etc., complete with all lead | Cum | 7420.37 | 7420.37 | 3.96 | False | None | None | False | None | False | 29384.6652 | 0 | 2349330 | 69468 | None | 005 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
---- etc., complete with all lead | Cum | 8085.81 | 8085.81 | 7.39 | False | None | None | False | None | False | 59754.1359 | 0 | 2349331 | 69468 | None | 006 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
---- etc., complete with all lead | Cum | 8635.33 | 8635.33 | 17.94 | False | None | None | False | None | False | 154917.8202 | 0 | 2349332 | 69468 | None | 007 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.
---- etc., complete with all lead | Tonne | 110837.22 | 110837.22 | 2.69 | False | None | None | False | None | False | 298152.1218 | 0 | 2349333 | 69468 | None | 008 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.
---- etc., complete with all lead | Sqm | 1012.26 | 1012.26 | 92.0 | False | None | None | False | None | False | 93127.92 | 0 | 2349334 | 69468 | None | 009 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
---- etc., complete with all lead | Sqm | 438.61 | 438.61 | 192.96 | False | None | None | False | None | False | 84634.1856 | 0 | 2349335 | 69468 | None | 010 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
---- etc., complete with all lead | Sqm | 400.2 | 400.2 | 36.96 | False | None | None | False | None | False | 14791.392 | 0 | 2349336 | 69468 | None | 011 | Providing & fixing 455x610 mm cast iron cover with frame weight to be not less 38kgs (weight of cover 23 kgs and weight of frame 15 kgs)and necessary locking arrangements with M.S flats 32x6 mm etc & painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge.
---- etc., complete with all lead | Nos | 2430.92 | 2430.92 | 2.0 | False | None | None | False | None | False | 4861.84 | 0 |
| 1706682498000 | 0 | None | None | Buildings | WATER SUPPLY & SANITARY WORKS | 1476313.12 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2349337 | 69469 | None | 001 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.40mm dia pipes, From wash basin waste lines
---- etc., complete with all lead | m | 109.03 | 109.03 | 50.0 | False | None | None | False | None | False | 5451.5 | 0 | 2349338 | 69469 | None | 002 | Providing and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make including trench excavation and refilling etc.50mm nominal bore pipes, From Sink
---- etc., complete with all lead | m | 172.22 | 172.22 | 20.0 | False | None | None | False | None | False | 3444.4 | 0 | 2349339 | 69469 | None | 003 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 75mm dia., 6 kg/sqcm & class 3 - Internal piping
---- etc., complete with all lead | m | 272.58 | 272.58 | 100.0 | False | None | None | False | None | False | 27258.0 | 0 | 2349340 | 69469 | None | 004 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 110mm dia., 6 kg/sqcm & class 3 - Internal piping
---- etc., complete with all lead | m | 509.23 | 509.23 | 100.0 | False | None | None | False | None | False | 50923.0 | 0 | 2349341 | 69469 | None | 005 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid
---- etc., complete with all lead | Each | 7405.5 | 7405.5 | 30.0 | False | None | None | False | None | False | 222165.0 | 0 | 2349342 | 69469 | None | 006 | Providing and fixing P.V.C. waste pipe for sink or wash basin & closet including P.V.C. waste fittings complete - Flexible pipe - 32/40mm dia
---- etc., complete with all lead | Each | 113.99 | 113.99 | 10.0 | False | None | None | False | None | False | 1139.9 | 0 | 2349343 | 69469 | None | 007 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.
---- etc., complete with all lead | Each | 898.28 | 898.28 | 10.0 | False | None | None | False | None | False | 8982.8 | 0 | 2349344 | 69469 | None | 008 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps.
---- etc., complete with all lead | Each | 3818.6 | 3818.6 | 10.0 | False | None | None | False | None | False | 38186.0 | 0 | 2349345 | 69469 | None | 009 | Providing and fixing brass bib cock of approved quality : 15 mm nominal bore
---- etc., complete with all lead | Nos | 354.35 | 354.35 | 60.0 | False | None | None | False | None | False | 21261.0 | 0 | 2349346 | 69469 | None | 010 | Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0 cm X 4.0 cm with all fitting arrangements & all necessary accessories
complete
---- etc., complete with all lead | Each | 302.32 | 302.32 | 30.0 | False | None | None | False | None | False | 9069.6 | 0 | 2349347 | 69469 | None | 011 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
Internal work - 20 mm nominal dia Pipes ---- etc., complete with all lead | Mtr | 268.86 | 268.86 | 80.0 | False | None | None | False | None | False | 21508.8 | 0 | 2349348 | 69469 | None | 012 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
Internal work - 25 mm nominal dia Pipes ---- etc., complete with all lead | Mtr | 366.74 | 366.74 | 250.0 | False | None | None | False | None | False | 91685.0 | 0 | 2349349 | 69469 | None | 013 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
Internal work - 40 mm nominal dia Pipes ---- etc., complete with all lead | Mtr | 591.0 | 591.0 | 100.0 | False | None | None | False | None | False | 59100.0 | 0 | 2349350 | 69469 | None | 014 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
Internal work - 50 mm nominal dia Pipes
---- etc., complete with all lead | Mtr | 893.32 | 893.32 | 100.0 | False | None | None | False | None | False | 89332.0 | 0 | 2349351 | 69469 | None | 015 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) 25 mm dia
---- etc., complete with all lead | Nos | 680.21 | 680.21 | 12.0 | False | None | None | False | None | False | 8162.52 | 0 | 2349352 | 69469 | None | 016 | Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.
---- etc., complete with all lead | Each | 6757.51 | 6757.51 | 60.0 | False | None | None | False | None | False | 405450.6 | 0 | 2349353 | 69469 | None | 017 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
---- etc., complete with all lead | Ltr | 11.15 | 11.15 | 2000.0 | False | None | None | False | None | False | 22300.0 | 0 | 2349354 | 69469 | None | 018 | Providing UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning,including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete for: Pipes of SN4, 200mm dia
---- etc., complete with all lead | Mtr | 1029.61 | 1029.61 | 300.0 | False | None | None | False | None | False | 308883.0 | 0 | 2349355 | 69469 | None | 019 | roviding and fixing testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577
---- etc., complete with all lead | Each | 1947.0 | 1947.0 | 30.0 | False | None | None | False | None | False | 58410.0 | 0 | 2349356 | 69469 | None | 020 | Providing and fixing, testing and commissioning approved make submersible pump made of C.I Construction suitable for building application. Thequoted rate shall also include for auto lvl.controller. providing necessary safety devices viz. dry run protection, over load relays etc., complete working on 230V, 50Hz, 1Ph, with starter,Duty of Pump : 6.0cum/hr @ 35.0m Head (1 No. Working + 1 No. Stand By)
---- etc., complete with all lead | Each | 23600.0 | 23600.0 | 1.0 | False | None | None | False | None | False | 23600.0 | 0 |
| 1706682498000 | 1 | None | None | Buildings | CONSTRUCTION OF MEETING HALL AT FIRST FLOOR | 1971107.68 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2349357 | 69470 | None | 001 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork FIRST FLOOR COLUMNS
---- etc., complete with all lead | Cum | 14557.54 | 14557.54 | 6.48 | False | None | None | False | None | False | 94332.8592 | 0 | 2349358 | 69470 | None | 002 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork FIRST FLOOR LINTEL
---- etc., complete with all lead | Cum | 13701.22 | 13701.22 | 1.74 | False | None | None | False | None | False | 23840.1228 | 0 | 2349359 | 69470 | None | 003 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork FIRST FLOOR
---- etc., complete with all lead | Cum | 12030.24 | 12030.24 | 1.42 | False | None | None | False | None | False | 17082.9408 | 0 | 2349360 | 69470 | None | 004 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. FIRST FLOOR
---- etc., complete with all lead | Tonne | 111945.6 | 111945.6 | 1.2 | False | None | None | False | None | False | 134334.72 | 0 | 2349361 | 69470 | None | 005 | Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. FIRST FLOOR
---- etc., complete with all lead | Rmtr | 39.33 | 39.33 | 39.2 | False | None | None | False | None | False | 1541.736 | 0 | 2349362 | 69470 | None | 006 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. FIRST FLOOR
---- etc., complete with all lead | Sqm | 1639.33 | 1639.33 | 124.2 | False | None | None | False | None | False | 203604.786 | 0 | 2349363 | 69470 | None | 007 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. FIRST FLOOR
---- etc., complete with all lead | Cum | 123656.11 | 123656.11 | 0.11 | False | None | None | False | None | False | 13602.1721 | 0 | 2349364 | 69470 | None | 008 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. FIRST FLOOR
---- etc., complete with all lead | Nos | 1271.41 | 1271.41 | 1.0 | False | None | None | False | None | False | 1271.41 | 0 | 2349365 | 69470 | None | 009 | Providing and fixing Stainless Steel Fixtures conforming to 304
graded steel as per direction of engineer in charge.SS Handles 300mm FIRST FLOOR ---- etc., complete with all lead | Nos | 688.27 | 688.27 | 2.0 | False | None | None | False | None | False | 1376.54 | 0 | 2349366 | 69470 | None | 010 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Aldrop 16mm dia, 300mm FIRST FLOOR ---- etc., complete with all lead | Nos | 469.27 | 469.27 | 1.0 | False | None | None | False | None | False | 469.27 | 0 | 2349367 | 69470 | None | 011 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Tower Bolts 200x10mm FIRST FLOOR
---- etc., complete with all lead | Nos | 187.71 | 187.71 | 2.0 | False | None | None | False | None | False | 375.42 | 0 | 2349368 | 69470 | None | 012 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS hinges 100 mm FIRST FLOOR
---- etc., complete with all lead | Nos | 87.6 | 87.6 | 4.0 | False | None | None | False | None | False | 350.4 | 0 | 2349369 | 69470 | None | 013 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Door stopper 75mm FIRST FLOOR
---- etc., complete with all lead | Nos | 125.14 | 125.14 | 1.0 | False | None | None | False | None | False | 125.14 | 0 | 2349370 | 69470 | None | 014 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. FIRST FLOOR
---- etc., complete with all lead | Nos | 1316.47 | 1316.47 | 1.0 | False | None | None | False | None | False | 1316.47 | 0 | 2349371 | 69470 | None | 015 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm FIRST FLOOR
---- etc., complete with all lead | Nos | 75.08 | 75.08 | 6.0 | False | None | None | False | None | False | 450.48 | 0 | 2349372 | 69470 | None | 016 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-do- 35 mm thick both side Commercial FIRST FLOOR
---- etc., complete with all lead | Sqm | 4157.12 | 4157.12 | 3.6 | False | None | None | False | None | False | 14965.632 | 0 | 2349373 | 69470 | None | 017 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL 9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile through out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made) FIRST FLOOR ---- etc., complete with all lead | Sqm | 8426.86 | 8426.86 | 27.0 | False | None | None | False | None | False | 227525.22 | 0 | 2349374 | 69470 | None | 018 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding FIRST FLOOR
---- etc., complete with all lead | Kgs | 210.23 | 210.23 | 567.0 | False | None | None | False | None | False | 119200.41 | 0 | 2349375 | 69470 | None | 019 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. FIRST FLOOR
---- etc., complete with all lead | Nos | 1394.05 | 1394.05 | 1.0 | False | None | None | False | None | False | 1394.05 | 0 | 2349376 | 69470 | None | 020 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Inside) FIRST FLOOR
---- etc., complete with all lead | Sqm | 390.44 | 390.44 | 140.29 | False | None | None | False | None | False | 54774.8276 | 0 | 2349377 | 69470 | None | 021 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. FIRST FLOOR
---- etc., complete with all lead | Sqm | 125.14 | 125.14 | 140.29 | False | None | None | False | None | False | 17555.8906 | 0 | 2349378 | 69470 | None | 022 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Outside) FIRST FLOOR
---- etc., complete with all lead | Sqm | 436.73 | 436.73 | 139.5 | False | None | None | False | None | False | 60923.835 | 0 | 2349379 | 69470 | None | 023 | Providing and fixing suitable plaster mesh 150mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment.Plaster mesh 150mm wide FIRST FLOOR
---- etc., complete with all lead | Rmtr | 47.55 | 47.55 | 172.8 | False | None | None | False | None | False | 8216.64 | 0 | 2349380 | 69470 | None | 024 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. FIRST FLOOR
---- etc., complete with all lead | Rmtr | 65.08 | 65.08 | 86.4 | False | None | None | False | None | False | 5622.912 | 0 | 2349381 | 69470 | None | 025 | Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm FIRST FLOOR
---- etc., complete with all lead | Sqm | 1470.39 | 1470.39 | 101.65 | False | None | None | False | None | False | 149465.1435 | 0 | 2349382 | 69470 | None | 026 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FIRST FLOOR
---- etc., complete with all lead | Sqm | 158.92 | 158.92 | 140.29 | False | None | None | False | None | False | 22294.8868 | 0 | 2349383 | 69470 | None | 027 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FIRST FLOOR
---- etc., complete with all lead | Sqm | 195.22 | 195.22 | 139.5 | False | None | None | False | None | False | 27233.19 | 0 | 2349384 | 69470 | None | 028 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FIRST FLOOR
---- etc., complete with all lead | Sqm | 62.57 | 62.57 | 27.0 | False | None | None | False | None | False | 1689.39 | 0 | 2349385 | 69470 | None | 029 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FIRST FLOOR
---- etc., complete with all lead | Sqm | 143.91 | 143.91 | 30.6 | False | None | None | False | None | False | 4403.646 | 0 | 2349386 | 69470 | None | 030 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FIRST FLOOR
---- etc., complete with all lead | Sqm | 66.33 | 66.33 | 8.64 | False | None | None | False | None | False | 573.0912 | 0 | 2349387 | 69470 | None | 031 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 110mm dia., 6 kg/sqcm & class 3 FIRST FLOOR
---- etc., complete with all lead | Mtr | 514.33 | 514.33 | 21.9 | False | None | None | False | None | False | 11263.827 | 0 | 2349388 | 69470 | None | 032 | Providing & fixing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete as per design drawings (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required as per the direction of Engineer in charge. 7.1.1 0.63 mm thick with zinc coating not less than 275 g/ m² FIRST FLOOR
---- etc., complete with all lead | Sqm | 1099.97 | 1099.97 | 112.5 | False | None | None | False | None | False | 123746.625 | 0 | 2349389 | 69470 | None | 033 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. - - etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. FIRST FLOOR
---- etc., complete with all lead | Kgs | 183.95 | 183.95 | 2700.0 | False | None | None | False | None | False | 496665.0 | 0 | 2349390 | 69470 | None | 034 | Mineral fibre ceiling tiles 595 x 595 and 19 mm thick, Basic Cost of Material serial no 534, page no:-A-28, FIRST FLOOR
---- etc., complete with all lead | Sqm | 1439.1 | 1439.1 | 90.0 | False | None | None | False | None | False | 129519.0 | 0 |
|
|
---|