createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1706533506774
version3
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee500.00
emd16250.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose07-02-2024 16:45:00
tenderQueryClose06-02-2024 16:01:01
technicalBidOpen08-02-2024 17:01:02
publishedDate31-01-2024 16:41:37
publishedByPostTMC_CO_ANKL
publishedByUserKPE11361 - SWAMY M R
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonSwamy M R
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber9845134814
tenderSupplierListNone
tenderSchedule
createdTs1706533506806
version4
createdDateNone
modifiedDateNone
tenderNumberDMA/2023-24/WS/WORK_INDENT13297
titleConstruction of open well for Pallikeri School and Kantri School.
descriptionConstruction of open well for Pallikeri School and Kantri School.
categoryWORKS
categoryTextWorks
ecv547164.48
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2422
locationNameDMA Town Municipal Council ANKOLA
provisionalAmount650000.0
groupOverheadTotal0.0
fileNumberTMC/ANK/05/15NMPC/Tied/2021-22
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17065335070000NoneNoneWater supply/sewage linesConstruction of open well for Pallikeri School and Kantri School.547164.48
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
233071868903None0001Earth work excavation for pipeline trenches by mechanical means above 600 mm (Depth upto 1.50m not exceeding 1.5m in width) trench width as per drawing and technical specification, including setting out, construction of shoring, strutting, Cost of blasting materials, barricading, caution lights, bracing, using sight rails & bonding rods at every 100 mm wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required, utilising the available excavated earth locally for the work and all other appurtenances to complete in the following strata. Depth upto 1.50mCum1310.41310.48.51FalseNoneNoneFalseNoneFalse11151.5040
233071968903None0002Earth work excavation for pipeline trenches by mechanical means above 600 mm (Depth upto 1.50m not exceeding 1.5m in width) trench width as per drawing and technical specification, including setting out, construction of shoring, strutting, Cost of blasting materials, barricading, caution lights, bracing, using sight rails & bonding rods at every 100 mm wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work and all other appurtenances to complete in the following strata. Depth exceeding 1.50m, but not exceeding 3mCum1429.121429.128.51FalseNoneNoneFalseNoneFalse12161.81120
233072068903None0003Earth work excavation for pipeline trenches by mechanical means above 600 mm (Depth upto 1.50m not exceeding 1.5m in width) trench width as per drawing and technical specification, including setting out, construction of shoring, strutting, Cost of blasting materials, barricading, caution lights, bracing, using sight rails & bonding rods at every 100 mm wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work and all other appurtenances to complete in the following strata. Depth exceeding 3.0m, but not exceeding 4.50mCum1514.241514.248.51FalseNoneNoneFalseNoneFalse12886.18240
233072168903None0004Earth work excavation for pipeline trenches by mechanical means above 600 mm (Depth upto 1.50m not exceeding 1.5m in width) trench width as per drawing and technical specification, including setting out, construction of shoring, strutting, Cost of blasting materials, barricading, caution lights, bracing, using sight rails & bonding rods at every 100 mm wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work and all other appurtenances to complete in the following strata. Depth exceeding 4.5m, but not exceeding 6.0mCum1581.221581.228.51FalseNoneNoneFalseNoneFalse13456.18220
233072268903None0005Earth work excavation for pipeline trenches by mechanical means above 600 mm (Depth upto 1.50m not exceeding 1.5m in width) trench width as per drawing and technical specification, including setting out, construction of shoring, strutting, Cost of blasting materials, barricading, caution lights, bracing, using sight rails & bonding rods at every 100 mm wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work and all other appurtenances to complete in the following strata. Depth exceeding 6.0m, but not exceeding 7.50mCum1648.191648.198.51FalseNoneNoneFalseNoneFalse14026.09690
233072368903None0006Earth work excavation for pipeline trenches by mechanical means above 600 mm (Depth upto 1.50m not exceeding 1.5m in width) trench width as per drawing and technical specification, including setting out, construction of shoring, strutting, Cost of blasting materials, barricading, caution lights, bracing, using sight rails & bonding rods at every 100 mm wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work and all other appurtenances to complete in the following strata. Depth exceeding 7.50m, but not exceeding 9.0mCum1715.171715.178.51FalseNoneNoneFalseNoneFalse14596.09670
233072468903None0007Earth work excavation for pipeline trenches by mechanical means above 600 mm (Depth upto 1.50m not exceeding 1.5m in width) trench width as per drawing and technical specification, including setting out, construction of shoring, strutting, Cost of blasting materials, barricading, caution lights, bracing, using sight rails & bonding rods at every 100 mm wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work and all other appurtenances to complete in the following strata. Depth exceeding 9.0m, but not exceeding 10.50mCum1782.141782.148.51FalseNoneNoneFalseNoneFalse15166.01140
233072568903None0008Earth work excavation for pipeline trenches by mechanical means above 600 mm (Depth upto 1.50m not exceeding 1.5m in width) trench width as per drawing and technical specification, including setting out, construction of shoring, strutting, Cost of blasting materials, barricading, caution lights, bracing, using sight rails & bonding rods at every 100 mm wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work and all other appurtenances to complete in the following strata. Depth exceeding 10.50m, but not exceeding 12.0mCum1849.121849.128.51FalseNoneNoneFalseNoneFalse15736.01120
233072668903None0009Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical pecifications. M25 Design Mix Using 20 mm and down size graded crushed coarse aggregatesCum8515.588515.5815.91FalseNoneNoneFalseNoneFalse135482.87780
233072768903None00010Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specificationTonne88492.3288492.320.46FalseNoneNoneFalseNoneFalse40706.46720
233072868903None00011Providing and fixing Structural Steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all com- plete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer- in-ChargeKg118.72118.7243.56FalseNoneNoneFalseNoneFalse5171.44320
233072968903None00012Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum484.96484.9628.23FalseNoneNoneFalseNoneFalse13690.42080
233073068903None00013Providing, Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications, to work site with testing of as per instructions of engineer incharge of work and latest amendments etc complete. 1.00 HP/0.75KW 7STGEach14916.1614916.162.0FalseNoneNoneFalseNoneFalse29832.320
233073168903None00014Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter etc. complete. Upto 3HP pumpsEach7280.07280.02.0FalseNoneNoneFalseNoneFalse14560.00
233073268903None00015Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets.m44.844.824.0FalseNoneNoneFalseNoneFalse1075.20
233073368903None00016Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendmentsm616.0616.024.0FalseNoneNoneFalseNoneFalse14784.00
233073468903None00017Labour charges for erection of indoor type panel board and meter board units with all necessary materials and labour tools and equipments including cement concrete for foundation/bed etc,complete as per specification, with testing of as per instructions of engineer incharge of work.Job1512.01512.024.0FalseNoneNoneFalseNoneFalse36288.00
233073568903None00018Earthing: Providing and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm diaJob4200.04200.024.0FalseNoneNoneFalseNoneFalse100800.00
233073668903None00019Providing main connection from pole PVC insulated sheathed steel wire cable in new trench as per IS 1554/ 1988 with latest amendments with ISI mark from KPTCL pole to meter board unit.m151.2151.280.0FalseNoneNoneFalseNoneFalse12096.00
233073768903None00020Providing and fixing suitable for 1.1 KV class UG cable filled with necessary bitumen insulating compound complete with terminals, lamps, bolts, nuts and washers etc. with necessary materials and labour tools and equipments as per instructions of engineer incharge of work. 3.5x10 SqmEach504.0504.02.0FalseNoneNoneFalseNoneFalse1008.00
233073868903None00021Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tankLtr10.0810.081000.0FalseNoneNoneFalseNoneFalse10080.00
233073968903None00022Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingKg188.16188.16119.1FalseNoneNoneFalseNoneFalse22409.8560
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17065335080000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17065335080000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17065335080000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17065335190000NoneNoneELIGIBILITYConditions are apply as per bid documentNone
17065335290000NoneNoneELIGIBILITYAll scanned documents to be uploaded shall be in original and the Chief Officer reserves the right to verify the documents before approvalNone
17065335370000NoneNoneELIGIBILITYThe employer reserves the rights to Reject or accept any or all the tenders without assigning any reasonsNone
17065335450000NoneNoneELIGIBILITYThe tenderer should maintain the work during the defective liability period for 2 yearsNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneDepartment Registration DetailsCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneList of existing commitments and ongoing workCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Existing committed works
NoneNoneNoneNonePAN copyCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- PAN Copy
NoneNoneNoneNoneSimilar nature of work doneCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
PAN copyTrueTechnical Bid
PWD Contractor License certificateTrueTechnical Bid
GST registration certificateTrueTechnical Bid
Small Scale Industries CertificateFalseTechnical Bid
Annual Turnover CertificateTrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone