2353692 | 69612 | None | code01 | Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.In all kinds of soils Depth upto 1.5 m | Cum | 254.1 | 254.1 | 1.76 | False | None | None | False | None | False | 447.216 | 0 |
2353693 | 69612 | None | code02 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6288.45 | 6288.45 | 1.76 | False | None | None | False | None | False | 11067.672 | 0 |
2353694 | 69612 | None | code03 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances
required to complete the work as per technical specifications.Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6527.85 | 6527.85 | 1.3 | False | None | None | False | None | False | 8486.205 | 0 |
2353695 | 69612 | None | code04 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances
required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6601.35 | 6601.35 | 14.4 | False | None | None | False | None | False | 95059.44 | 0 |
2353696 | 69612 | None | code05 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m | Cum | 279.3 | 279.3 | 17.68 | False | None | None | False | None | False | 4938.024 | 0 |
2353697 | 69612 | None | code06 | Providing and TMT Steel reinforcement for R.C.C work including Straightening, cutting benmding, hooking, placing in position, lapping and or welding Wherever required, tying with binding wire and anchoring to the adjoining members wherever necessary complete as per design (laps, hooks and wastage shall not be measured and paid) cost of materials, labour, HOM of machinery complete as per specification. specifications. | Kgs | 93.93 | 93.93 | 493.8 | False | None | None | False | None | False | 46382.634 | 0 |
2353698 | 69612 | None | code07 | Providing and Removing centring shuttering, shuttering, propping etc, and removal of form work for surface such as suspended floors,roofs, landings, balconies and likes, thickness up to 200mm including cost of all materials, labour, complete as per specifications. 0.00 to 5.00 mts | Sqm | 426.3 | 426.3 | 54.36 | False | None | None | False | None | False | 23173.668 | 0 |
2353699 | 69612 | None | code08 | Providing and laying Vitrified tiles with thickness 9-10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 600x600 mm | Sqm | 1299.9 | 1299.9 | 53.34 | False | None | None | False | None | False | 69336.666 | 0 |
2353700 | 69612 | None | code09 | Open Conduit System Supplying heavy gauge PVC conduit pipe 25 mm dia confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 25mm dia 2mm thick | Mtr | 81.0 | 81.0 | 80.0 | False | None | None | False | None | False | 6480.0 | 0 |
2353701 | 69612 | None | code10 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, necessary masonry patch work complete. 8"x6"x3" (203x152x76mm) | Each | 86.0 | 86.0 | 12.0 | False | None | None | False | None | False | 1032.0 | 0 |
2353702 | 69612 | None | code11 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using copper PVC insulated multi strand 2x1.5Sqmm copper wire with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. I. Point wiring using class A Materialsa) Short point up to 3Mtr from tapping point to out let via switch | Each Point | 285.0 | 285.0 | 2.0 | False | None | None | False | None | False | 570.0 | 0 |
2353703 | 69612 | None | code12 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using copper PVC insulated multi strand 2x1.5Sqmm copper wire with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. I. Point wiring using class A Materials b) Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch | Each Point | 394.0 | 394.0 | 4.0 | False | None | None | False | None | False | 1576.0 | 0 |
2353704 | 69612 | None | code13 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using copper PVC insulated multi strand 2x1.5Sqmm copper wire with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet I. Point wiring using class A Materials c) Long point above 6Mtr up to 10Mtr from tapping point to out let via switch | Each Point | 1035.0 | 1035.0 | 8.0 | False | None | None | False | None | False | 8280.0 | 0 |
2353705 | 69612 | None | code14 | Supplying 6A flush/projected type socket and 6 amps flush/projected type SP switch either surface/flush mounting in a existing gang box or in a 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required. b) 6Amps 3/5 Way | Each | 147.0 | 147.0 | 4.0 | False | None | None | False | None | False | 588.0 | 0 |
2353706 | 69612 | None | code15 | Supplying and fixing of Bakelite D.P/Socket/Switch with/without neon indicator over existing wood board or flush mounting in plastic plates/nitches as per IS 16 Amps SP switch | Each | 68.0 | 68.0 | 4.0 | False | None | None | False | None | False | 272.0 | 0 |
2353707 | 69612 | None | code16 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper Wire with low conductor resistance core in open or concealed system of wiring with specified IS-694 :confirming to latest amendments.I. 1.5 sqmm (Copper wire) | Mtr | 26.0 | 26.0 | 140.0 | False | None | None | False | None | False | 3640.0 | 0 |
2353708 | 69612 | None | code17 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper Wire with low conductor resistance core in open or concealed system of wiring with specified IS-694 :confirming to latest amendments.I. 2.5 sqmm (Copper wire) | Mtr | 42.0 | 42.0 | 60.0 | False | None | None | False | None | False | 2520.0 | 0 |
2353709 | 69612 | None | code18 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper Wire with low conductor resistance core in open or concealed system of wiring with specified IS-694 :confirming to latest amendments.I. 6 sqmm (Copper wire) | Mtr | 92.0 | 92.0 | 120.0 | False | None | None | False | None | False | 11040.0 | 0 |
2353710 | 69612 | None | code19 | Supplying 4mm thick plastic sheet with necessary nitches for fixing switches regulators etc., and fixing on existing wooden or metal box using N.F. screws. | Sq CM | 0.41 | 0.41 | 3000.0 | False | None | None | False | None | False | 1230.0 | 0 |
2353711 | 69612 | None | code20 | Supplying and fixing retrofit type -PL- LED Lamp W LED linear source with CCT 6500 degree K, CRI 70 percentage . Efficiency 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322 IEC60598, LM and LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95 power loss should 5percentage of lamp wattage., short circuit, THD less than 20percentage, Life as per LM79. The operating input voltage should bebetween 130 to 275 volts. Tested by NABL CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.18-20 watts. | Each | 330.0 | 330.0 | 6.0 | False | None | None | False | None | False | 1980.0 | 0 |
2353712 | 69612 | None | code21 | Fixing all types and all capacities of fluorescent false ceiling spot light CFL fittings indoor on the wall ceiling rafters girders using 23 0.0076 twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall ceiling Rafter Girders | Each | 122.0 | 122.0 | 6.0 | False | None | None | False | None | False | 732.0 | 0 |
2353713 | 69612 | None | code22 | Supply & fixing using.mm dia class A GI pipe bracket up to 2.7mtrs long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/tubular pole using suitable clamps, bolts, nuts & wiring using suitable capacity wires. Using 25mm G.I. Pipe | Each | 978.0 | 978.0 | 4.0 | False | None | None | False | None | False | 3912.0 | 0 |
2353714 | 69612 | None | code23 | Supply and fixing polished wood board made of not less than 15mm thick plank on both sides with planks made out of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws etc. 20"x20"x2.5" | Each | 326.13 | 326.13 | 4.0 | False | None | None | False | None | False | 1304.52 | 0 |
2353715 | 69612 | None | code24 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. 32Amps | Each | 241.0 | 241.0 | 4.0 | False | None | None | False | None | False | 964.0 | 0 |
2353716 | 69612 | None | code25 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve , indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 40 Amps DP | Each | 1060.0 | 1060.0 | 2.0 | False | None | None | False | None | False | 2120.0 | 0 |
2353717 | 69612 | None | code26 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve , indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 Amps DP | Each | 415.0 | 415.0 | 8.0 | False | None | None | False | None | False | 3320.0 | 0 |
2353718 | 69612 | None | code27 | Supplying, fixing and wiring electronic 5 to 20Amps SIngle phase Class-1 Accuracy Energy Meter | Each | 1380.0 | 1380.0 | 2.0 | False | None | None | False | None | False | 2760.0 | 0 |
2353719 | 69612 | None | code28 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipments on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit … The pit should be filled with equal proprotion of salt and charcoal 150mm alround the pipe to complete depth. The connection from the pipe to the conduit etc, is to be established through GI wire of size as per ISI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and checknuts etc, the pipe shall have 16 through holes of 122 mm dia. | Rmtr | 3510.0 | 3510.0 | 4.0 | False | None | None | False | None | False | 14040.0 | 0 |
2353720 | 69612 | None | code29 | Supplying and running of GI strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip
| Mtr | 82.0 | 82.0 | 30.0 | False | None | None | False | None | False | 2460.0 | 0 |
2353721 | 69612 | None | code30 | Supplying of LT UG cable having aluminium conductor PVC insulated, sheathed, galvanised, steel wire/steel tap armoured cable with PVC outer sheathing 1.1 KV class. Class A PVC Cable 4 core 16 sqmm | Mtr | 577.0 | 577.0 | 50.0 | False | None | None | False | None | False | 28850.0 | 0 |
2353722 | 69612 | None | code31 | Labour charges for laying of 1.1 KV class UG cable when supplied agency in existing trench GI pipe / stoneware pipe / on wall / on pole as required. In exixting trench/duct. 6 sqmm to 16 sqmm | 50 Kg | 11.88 | 11.88 | 50.0 | False | None | None | False | None | False | 594.0 | 0 |
2353723 | 69612 | None | code32 | Digging of trench of 0.6m deep x 0.50 mtr wide refiling the trench to the required ground level and consolidating etc., complete.(As per Civil SR KSRB I-2, P-7) In soil (hard). | Mtr | 102.0 | 102.0 | 40.0 | False | None | None | False | None | False | 4080.0 | 0 |
2353724 | 69612 | None | code33 | Supplying and fixing of class A (medium duty) GI pipe of wall thick ness not less than 3.25mm on pole/wall/drain crossing with necessary clamping arrangements for UG cable of 1.1 KV class. 40mm | Mtr | 335.0 | 335.0 | 10.0 | False | None | None | False | None | False | 3350.0 | 0 |
2353725 | 69612 | None | code34 | Supplying and fixing L.T. cast Iron pot heads suitable for 1.1 KV class UG cable filled with necessary bituumen/insulating compound complete with terminals, clamps, bolts, nuts and washers etc. 16 Sqmm | Each | 270.0 | 270.0 | 2.0 | False | None | None | False | None | False | 540.0 | 0 |
2353726 | 69612 | None | code36 | Providing and errecting the name board of size 10ft X 2ft made up of aluminium composite panel with 3mm thick at site of work for water purification plant including printing on self adhesive vinyl sheet/ pasting it on the panel with suitable color etc., complete as per Specification and direction of Engineer in charge | Each | 6000.0 | 6000.0 | 2.0 | False | None | None | False | None | False | 12000.0 | 0 |
2353727 | 69612 | None | code37 | uPVC cabin for housing : Providing fabricating and construction of uPVC lift and shift porta cabins made out of MS 100mm C section for base with middle, vertical and for roof supports welded with 50X50 and 40mmx20mm M.S tubes and angles for structures, uPVC panels 20x155x1.2mm and 355x20x1.2mm extruded sections fixed on both side by hidden screwing system with uPVC false ceiling. Door frame made out of uPVC false extruded profiles with accessories etc., complete of size w 1.00x2.10 and 2.40x2.10 mtr, window 2 no of size 0.90x1.00 mtrs made out of uPVC extruded profiles with 5mm plain glass shutters as approved specification, the ceiling clear height of 2.85 and 2.75 mtrs, roofing of pre-coated G.I. sheet standard make of 0.45mm thick and suitable lifting arrangements will be provided to portal cabins with a patition for ATM chamber, overall size 6.06 x 3.06m including cost of material, labour, loading, unloading, erection at various sites as per enclosed drawing and the directions of the engineer in charge of the RWS. | Each | 268000.0 | 268000.0 | 2.0 | False | None | None | False | None | False | 536000.0 | 0 |
2353728 | 69612 | None | code38 | Water purification plants: Supplying, Installation and Commissioning of automatic Water purification plant (RO+UF) with all accessories piping, product water tank on single phase power supply on Turkey / EPC Basis as per the enclosed detailed Technical Specifications including cost of material, loading and unloading and as directed by the Engineer in charge. (Ref- detailed specification enclosed seperatly before Procurement ) (Common SR 2023-24 Vol-4 Page No.247,Item No.21.1.10) | Each | 416000.0 | 416000.0 | 2.0 | False | None | None | False | None | False | 832000.0 | 0 |
2353729 | 69612 | None | code39 | Raw water storage Tank 5000ltr Capacity | Ltr | 5.08 | 5.08 | 10000.0 | False | None | None | False | None | False | 50800.0 | 0 |
2353730 | 69612 | None | code40 | Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. | Cum | 508.2 | 508.2 | 244.8 | False | None | None | False | None | False | 124407.36 | 0 |
2353731 | 69612 | None | code41 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest
amendments and conveying to worksite, rolling and lowering into
trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depthof not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc | Rmtr | 231.0 | 231.0 | 680.0 | False | None | None | False | None | False | 157080.0 | 0 |