createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1706617574031
version2
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee980.00
emd92000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose07-02-2024 16:00:00
tenderQueryClose03-02-2024 16:00:00
technicalBidOpen08-02-2024 17:00:00
publishedDate31-01-2024 15:25:51
publishedByPostTMC_CO_PYP
publishedByUserKPE14293 - K U MUTHAPPA
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonVanitha M.S.
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedNone
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber9483826488
tenderSupplierListNone
tenderSchedule
createdTs1706617574064
version4
createdDateNone
modifiedDateNone
tenderNumberDMA/2023-24/OW/WORK_INDENT13792
titleConstruction of compound wall water supply and electrical work in Indira Canteen TMC Periyapatna
descriptionConstruction of compound wall water supply and electrical work in Indira Canteen TMC Periyapatna
categoryWORKS
categoryTextWorks
ecv3883631.72
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2448
locationNameDMA Town Municipal Council Piriyapattana
provisionalAmount4600000.0
groupOverheadTotalNone
fileNumberJE2/TENDER-26/01/2023-24
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17066175740000NoneNoneOther WorksConstruction of compound wall water supply and electrical work in Indira Canteen TMC Periyapatna3883631.72
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
234054969248NoneVol-3, 2023-24, Item no. 2.11.II A. bDismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead : By Mechanical means : Dismantling Brick / Tile work / rubble masonry / pitching / etc by mechanical meansCum185.4185.410.8FalseNoneNoneFalseNoneFalse2002.320
234055069248NoneVol-3, 2023-24, Item no. 2.24. b, Page No.12Dismantling of barbed wire fencing/ wire mesh fencing including posts, foundation concrete, back filling of pit by manual means including disposal of dismantled material with all lifts and lead, stacking serviceable material and unserviceable material separatelyMtr99.9199.9130.0FalseNoneNoneFalseNoneFalse2997.30
234055169248NoneVol-3, 2023-24, Item no.3.6 Page No.17Construction of sub-grade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slopeCum507.79507.7945.0FalseNoneNoneFalseNoneFalse22850.550
234055269248NoneVol-3, 2023-24, Item no.3.7 Page No.17Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment constructionCum108.15108.1545.0FalseNoneNoneFalseNoneFalse4866.750
234055369248NoneVol-1, 2023-24, Item no. 1.17.1, Page No.10Earth work excavation for pipeline trenches in all kinds of soils by mechanical means above 600 mm trench width as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & boning rods at every 100 mm whevere necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata.Cum269.86269.86176.0FalseNoneNoneFalseNoneFalse47495.360
234055469248NoneVol-01, 2023-24, Item no. 2.1.2, Page No.15Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregatesCum5833.925833.9251.83FalseNoneNoneFalseNoneFalse302372.07360
234055569248NoneVol-1 SR 2023-24, Item No. 2.11a, Page No. 18Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.Tonne81381.3381381.333.18FalseNoneNoneFalseNoneFalse258792.62940
234055669248NoneVol.1, 2023-24, Item no. 2.5.2, Page No.16Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7400.77400.796.3FalseNoneNoneFalseNoneFalse712687.410
234055769248NoneVol.1, 2023-24, Item no. 2.4.3, Page No.16Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6852.386852.388.56FalseNoneNoneFalseNoneFalse58656.37280
234055869248NoneVol 3, Item no. 3.1, Page No.17Removal of Unserviceable Soil with Disposal up to a suitable distance as directed by the Engineer in charge of workCum87.5587.55176.0FalseNoneNoneFalseNoneFalse15408.80
234055969248NoneVol-2, Item no. 11.25.2, Page No.84Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kgs140.08140.089760.5FalseNoneNoneFalseNoneFalse1367250.840
234056069248NoneVol-2, Item no. 11.16.1, Page No.82Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-ChargeKgs140.08140.081874.88FalseNoneNoneFalseNoneFalse262633.19040
234056169248NoneVol-2, Item no. 11.28, Page No.85Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-ChargeKgs581.95581.9510.26FalseNoneNoneFalseNoneFalse5970.8070
234056269248NoneVol-02, Item no. 8.33, Page No.47Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-chargeSqm143.17143.17312.9FalseNoneNoneFalseNoneFalse44797.8930
234056369248NoneVol-03, Item no. 6.8.3, Page No.52Providing and laying 100mm thick factory made precast M -40 grade Cement Concrete Paver Block as per IRC SP 63:2018 & IS 15658 for Commercial Traffic Axle load repetitions more than 10MSA upto 20MSA for Industrial Streets, Bus & Truck parking of approved shape and colour, laid in required pattern and including over 40mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.Sqm1339.01339.0270.0FalseNoneNoneFalseNoneFalse361530.00
234056469248NoneVol-03, Item no. 8.42.3 Page No.74Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge.Mtr476.89476.8950.0FalseNoneNoneFalseNoneFalse23844.50
234056569248NoneVol-02, Item no. 8.33.1, Page No.46Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-chargeSqm162.74162.74198.0FalseNoneNoneFalseNoneFalse32222.520
234056669248NoneVol-08, Item no. 1.2, Page No.1Procurement of Ingredients: Procurement of farm yard manure/compost, sand and red-earth (ingredients) required for raising seedlings inclusive of transportation, breaking of clods, sieving and heaping eaching redient separately at nursery site Fine coarse Red-earth/soilSqm555.36555.3690.0FalseNoneNoneFalseNoneFalse49982.40
234056769248NoneVol-08, Item no. 12.10 G(c), Page No.49Procurement of quality lawn grass, Mexican Grass TurfSqm206.0206.090.0FalseNoneNoneFalseNoneFalse18540.00
234056869248NoneVol-08, Item no. 12.10 H(c), Page No.50Labour Charges: mixing Input s as per prescribed proportion and quantity and spreading, applying fertilizers, digging, levelling, and dibbling with lawn grass at a spacing of 5cmx5cm & as per the direction of the Officer in charge of the work., Mexican Grass TurfSqm602.55602.5590.0FalseNoneNoneFalseNoneFalse54229.50
234056969248NoneVol-02, Item No.13.55 Page No.127Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 600X850 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc.Each7623.037623.032.0FalseNoneNoneFalseNoneFalse15246.060
234057069248NoneVol-05, l no. 10.1.2, Page No.113Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testingand commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:PVC pipes 32mm dia., 10 kg/sqcm & class 5.Mtr69.0169.01120.0FalseNoneNoneFalseNoneFalse8281.20
234057169248NoneVol-05, l no. 10.2.4, Page No.114Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISSMtr593.28593.2840.0FalseNoneNoneFalseNoneFalse23731.20
234057269248NoneVol-05, ltem no.10.8.2, Page No.116Supply and delivery at site special moulded variety PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments.32mm dia PVC couplersEach16.4816.4810.0FalseNoneNoneFalseNoneFalse164.80
234057369248NoneVol-05, ltem no. 10.9.2, Page No.117Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.32 mm dia PVC Elbows.Each21.6321.6315.0FalseNoneNoneFalseNoneFalse324.450
234057469248NoneVol-05, ltem no. 10.11.2, Page No.118Supply and delivery at site special moulded variety PVC bend as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.32 mm dia PVC BENDEach37.0837.086.0FalseNoneNoneFalseNoneFalse222.480
234057569248NoneVol-02, Sl no. 13.34A, Page No.123Providing and fixing rectangular high density polyethylene water storage loft tank with cover, conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includes making necessary holes for inlet, outlet & over flow pipes. The base support i/c fittings & fixtures for tank shall be paid separately.(For 1000 litre capacity)Ltr9.279.271000.0FalseNoneNoneFalseNoneFalse9270.00
234057669248NoneVol-02, ltem no.13.4.2, Page No.117Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :32 mm nominal bore.Nos615.94615.942.0FalseNoneNoneFalseNoneFalse1231.880
234057769248NoneVol-02, ltem no.13.3.2, Page No.117Providing and fixing brass stop cock of approved quality : 20 mm nominal bore.Nos314.15314.154.0FalseNoneNoneFalseNoneFalse1256.60
234057869248NoneVol-02, ltem no.13.2.2, Page No.117Providing and fixing brass bib cock of approved quality.20 mm nominal boreNos314.15314.154.0FalseNoneNoneFalseNoneFalse1256.60
234057969248NoneIN-1.2.1, PN-2Supplying heavy gauge PVC conduit pipe . mm dia.mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary, 19/20 mm dia 2 mm thickMtr67.9867.9820.0FalseNoneNoneFalseNoneFalse1359.60
234058069248NoneIN-1.2.2, PN-2Supplying heavy gauge PVC conduit pipe . mm dia.mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary, 25 mm dia 2 mm thickMtr80.3480.3455.0FalseNoneNoneFalseNoneFalse4418.70
234058169248NoneIN-1.3.1, PN-2Supplying heavy gauge PVC Conduit Pipe . dia . mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 19/20 mm dia 2 mm thickMtr70.0470.0410.0FalseNoneNoneFalseNoneFalse700.40
234058269248NoneIN-1.3.2, PN-2Supplying heavy gauge PVC Conduit Pipe . dia . mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 25 mm dia 2 mm thickMtr81.3781.3720.0FalseNoneNoneFalseNoneFalse1627.40
234058369248NoneIN-2.2.1, PN-5Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outletMtr277.07277.072.0FalseNoneNoneFalseNoneFalse554.140
234058469248NoneIN-2.2.2, PN-5Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Point390.37390.376.0FalseNoneNoneFalseNoneFalse2342.220
234058569248NoneIN-2.2.2, PN-5Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Point571.65571.6516.0FalseNoneNoneFalseNoneFalse9146.40
234058669248NoneIN-2.3.2, PN-5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694 confirming to latest amendments.Mtr26.7826.7820.0FalseNoneNoneFalseNoneFalse535.60
234058769248NoneIN-2.3.3, PN-5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694 confirming to latest amendments.Mtr43.2643.2620.0FalseNoneNoneFalseNoneFalse865.20
234058869248NoneIN-2.3.4, PN-5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694 confirming to latest amendments.Mtr64.8964.8945.0FalseNoneNoneFalseNoneFalse2920.050
234058969248NoneIN-3.1.2, PN-8Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654Each151.41151.414.0FalseNoneNoneFalseNoneFalse605.640
234059069248NoneIN-6.3.3, PN-9Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.Each176.13176.1314.0FalseNoneNoneFalseNoneFalse2465.820
234059169248NoneIN-3.4.3, PN-8Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wallEach182.31182.311.0FalseNoneNoneFalseNoneFalse182.310
234059269248NoneIN-3.4.6, PN-8Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wallEach328.57328.572.0FalseNoneNoneFalseNoneFalse657.140
234059369248NoneIN-3.5.3, PN-8Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC boxEach180.25180.251.0FalseNoneNoneFalseNoneFalse180.250
234059469248NoneIN-3.5.7, PN-8Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC boxEach408.91408.912.0FalseNoneNoneFalseNoneFalse817.820
234059569248NoneIN-11.8.1, PN-46Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection.Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 5060Hz application. Compliance to IS 10322IEC 60598, LM 79 LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .25W System Power consumption. LED fficiency1301m/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentionedEach2497.752497.754.0FalseNoneNoneFalseNoneFalse9991.00
234059669248NoneIN-13.2.1, PN-56Supplying and Fixing.mm dia class A GI pipe bracket upto 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/ tubular pole, using suitable clA, bolts, nuts and wiring using suitable capacity wiresEach1239.091239.094.0FalseNoneNoneFalseNoneFalse4956.360
234059769248NoneIN-13.5, PN-56Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clA, bolts, nuts and wiring using suitable capacity wires.Each166.86166.864.0FalseNoneNoneFalseNoneFalse667.440
234059869248NoneIN-11.3.2, PN-43Supplying of .feet -PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours 70 lumen maintenance with CRI 80. Power Input: 220-240V 50/60Hz Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 42022WEach710.7710.78.0FalseNoneNoneFalseNoneFalse5685.60
234059969248NoneIN-11.4.2, PN-44Supplying of recess mounting non integrated type LED down light. W luminaire comprising of pressure decast extruded aluminium housing, with spring loaded false ceiling clA, LED of Power COB with CCT 6500 degree K, CRI 70. efficacy 100 lumen per W 120degree beam spread, life 25000 burning hours and Compliance to IS10322 IEC 60598 LM 79 LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 095, power loss should 5% of lamp Wage, short circuit & open circuit protection to be integrated in the circuit, THD less than 20, Life as per LM 79. The operating input voltage should be between 130 to 275 V BIS Approved and Tested by NABL CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 10 12WEach1307.071307.074.0FalseNoneNoneFalseNoneFalse5228.280
234060069248NoneIN-13.7.1, PN-56Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling /rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA. On wall/ ceiling / Rafter / GirdersEach125.66125.6610.0FalseNoneNoneFalseNoneFalse1256.60
234060169248NoneIN-3.14.6, PN-10Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board.Nos73.1373.136.0FalseNoneNoneFalseNoneFalse438.780
234060269248NoneIN-6.1, PN-30Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.Each1536.761536.766.0FalseNoneNoneFalseNoneFalse9220.560
234060369248NoneIN-13.13, PN-57Fixing one exhaust fan after making a suitable notch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 A, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.Each728.21728.216.0FalseNoneNoneFalseNoneFalse4369.260
234060469248NoneIN-5.18.4, PN-17Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.Each761.17761.172.0FalseNoneNoneFalseNoneFalse1522.340
234060569248NoneIN-5.42.2, PN-20Fabricating supplying and mounting MS box made out .SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.Sq CM0.440.448000.0FalseNoneNoneFalseNoneFalse3520.00
234060669248NoneIN-5.40.1, PN-20Supplying . A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete.Each2538.952538.951.0FalseNoneNoneFalseNoneFalse2538.950
234060769248NoneIN-5.30, PN-19Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 20A single phase Class-1 Accuracy with Temper Proof Energy MeterEach1421.41421.41.0FalseNoneNoneFalseNoneFalse1421.40
234060869248NoneIN-1.6.2, PN-43Digging of Pit for providing GI Pipe type Earthing, Hard SoilPer Pit3079.73079.71.0FalseNoneNoneFalseNoneFalse3079.70
234060969248NoneIN-54.01, PN-17GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolt, nut, GI Strips and washer complete Minimum Weight of GI Pipe: 7.3 Kg,No765.29765.291.0FalseNoneNoneFalseNoneFalse765.290
234061069248NoneIN-51.02, PN-22Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg eachNo696.28696.281.0FalseNoneNoneFalseNoneFalse696.280
234061169248NoneIN-51.03, PN-22Good Quality Salt for grounding purposes packed in 50 Kg gunny bagNo319.3319.31.0FalseNoneNoneFalseNoneFalse319.30
234061269248NoneIN-32.03, PN-131.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975Km121244.12121244.120.06FalseNoneNoneFalseNoneFalse7274.64720
234061369248NoneIN-21.05, PN-52Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT CableKm21512.5821512.580.06FalseNoneNoneFalseNoneFalse1290.75480
234061469248NoneIN-60.03, PN-27Aluminium End Terminal (Lug), 25 SqmmEach3.093.098.0FalseNoneNoneFalseNoneFalse24.720
234061569248NoneIN-49.04, PN-16GI Pipe B - Class as per IS-1239Mtr303.85303.854.0FalseNoneNoneFalseNoneFalse1215.40
234061669248NoneIN-35.01, PN-15Epoxy Terminating Kit (Pothead) suitable for 1.1 kV, LTUG CableSet333.72333.721.0FalseNoneNoneFalseNoneFalse333.720
234061769248NoneItem No.13.45, Page No.158Supply, delivery, erection and commissioning at site ELCB suitable for monoblock centrifugal pump confirming with ISI mark and its latest amendments.Set4240.514240.511.0FalseNoneNoneFalseNoneFalse4240.510
234061869248NoneItem No.34.2, Page No.52Fixed Camera Specifications Lens type Bifocal auto iris with 10 digital zoom Mode Day Night Image size: 720 486 NTSC Streaming: High speed Weather Proof: IP 66 compliant Network Protocol: TCP IP should be compliant of any other protocol required. Connectivity : Cat 6 Optical fibre Ethernet:10Base t 100Base TX(RJ45) Power source : both self powered and externally poweredSet12346.6112346.616.0FalseNoneNoneFalseNoneFalse74079.660
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17066175750000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17066175750000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17066175750000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17066176360000NoneNoneELIGIBILITYAchieved in at least two financial years an average annual financial turnover of Rs. 46.00 LakhsNone
17066176860000NoneNoneELIGIBILITYSatisfactorily completed, at least one civil work of value not less than Rs.23.00 Lakhs. as prime contractor Execute similar work like Compound wall WorksNone
17066178320000NoneNoneELIGIBILITYExecuted in one year the following minimum quantities of work (usually 80% of the annual of requirement) (1)Earth Work:140.80 cum (2)PCC & RCC:125.35 cum (3) TMT Steel:2.544 tonnes(4)Cement concrete paver blocks / interlocks:216.00sqm (5)Frame / Grills / Tube / Trusses work:9308.30KgsNone
17066178700000NoneNoneELIGIBILITYLiquid assets and or availability of credit facilities of not less than Rs. 13,80,000/-None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)NoneNone
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)NoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneProposals for subcontracting components of works amounting to more than 20% of the contract price (for each, the qualifications and experience of the identified sub-contractor in the relevant fields should be attached)NoneNone
NoneNoneNoneNoneQuantities of itemsOthersQuantities of items
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneContractor LicenseOthersContractor License
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneLine of credit / Bankers certificateOthersLine of credit / Bankers certificate
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneSimilar workOthersSimilar work
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneTurn OverOthersTurn Over
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
Company Registration Certificate / Contractor LicenceTrueTechnical Bid
GST CopyTrueTechnical Bid
PAN NoTrueTechnical Bid
Work certificateTrueTechnical Bid
Bankers certificate / Line of creditTrueTechnical Bid
tenderWorkLocationList
tenderSubEstimateNamedistrictNametaluqNameloksabhaContNameassemblyContNamelocationDescriptionlatitudeDegreeslatitudeMinuteslatitudeSecondslongitudeDegreeslongitudeMinuteslongitudeSeconds
Other WorksMysuruPiriyapattanaMysorePERIYAPATNABM Road, TMC, PeriyapatnaNoneNoneNoneNoneNoneNone
tenderAddressNone
tenderRecallDTONone