tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1706788256000 | 0 | None | None | Buildings | 1 Construction of Two Class Rooms for Government Higher Primary School at Shagyoti Village Gadag Dist Tq (32.80 Lakhs) | 2727715.55 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2381403 | 70805 | None | Vol No-1 pg no-08 I No 1.12 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurten ances required to complete the work. ---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 95.0 | 95.0 | 60.0 | False | None | None | False | None | False | 5700.0 | 0 | 2381404 | 70805 | None | Vol No-1 pg no-08 I No 1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the In all kinds of soils Depth upto 3 m ---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 102.0 | 102.0 | 218.75 | False | None | None | False | None | False | 22312.5 | 0 | 2381405 | 70805 | None | Vol No-2 pg no-05 I No 4.1 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with
Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage
charges of machinery, complete as per specific ations. ---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 118.0 | 118.0 | 128.33 | False | None | None | False | None | False | 15142.94 | 0 | 2381406 | 70805 | None | Vol No-2 pg no 11 I No 1.23 | Providing and Filling in foundation with granite / trap broken metal 100mm. And down size & with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift complete as per specifications. ---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 2682.0 | 2682.0 | 19.13 | False | None | None | False | None | False | 51306.66 | 0 | 2381407 | 70805 | None | Vol No-1 pg no-15 No 2.1.3 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggre gates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of
machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates ---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 5989.0 | 5989.0 | 31.82 | False | None | None | False | None | False | 190569.98 | 0 | 2381408 | 70805 | None | Vol No-1 pg no-15I No 2.2.3 | Providing and laying in position Cement Concrete for all Foundation works.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished
layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specification s.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 6336.0 | 6336.0 | 31.88 | False | None | None | False | None | False | 201991.68 | 0 | 2381409 | 70805 | None | Vol-1 pg No.-111 (8 Percentage ) | Additional for formwork, Centering & Scaffolding for Sl No 1 a: Foundation upto plinth Isolated As per Appendix-I in Volume-1 of page No.-111 (@8% of Finished Rate) ---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 506.88 | 506.88 | 31.88 | False | None | None | False | None | False | 16159.3344 | 0 | 2381410 | 70805 | None | Vol No-1 pg no-16I No 2.3.2 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/
basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 6480.0 | 6480.0 | 12.65 | False | None | None | False | None | False | 81972.0 | 0 | 2381411 | 70805 | None | Vol-1 pg No.-111 | Additional for formwork, Centering & Scaffolding for Sl No 9 : RCC Columns / Shaft (Slip Centering) in Volume-1 of page No.-111 (@70% of Finished Rate) ---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 4536.0 | 4536.0 | 2.08 | False | None | None | False | None | False | 9434.88 | 0 | 2381412 | 70805 | None | Vol-1 pg No.-112 | Additional for formwork, Centering & Scaffolding for Sl No 11 : Earth retaining structures in Volume-1 of page No.-112(@10% of Finished Rate) ---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 648.0 | 648.0 | 10.57 | False | None | None | False | None | False | 6849.36 | 0 | 2381413 | 70805 | None | Vol No-1 pg no-7I No 1.8 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. If the height of embankment construction is more than 1.50 m add 5% per for every 1.50 m height or part there off ---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 474.0 | 474.0 | 308.3 | False | None | None | False | None | False | 146134.2 | 0 | 2381414 | 70805 | None | Vol No-1 pg no-16I No2.4.1 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works &
other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS
Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregates ---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 6404.0 | 6404.0 | 1.67 | False | None | None | False | None | False | 10694.68 | 0 | 2381415 | 70805 | None | Vol No-1 pg no-16 I No 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse
aggrgates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The
cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications .M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 6843.0 | 6843.0 | 45.19 | False | None | None | False | None | False | 309235.17 | 0 | 2381416 | 70805 | None | Vol-1 pg No.-111 | Additional for formwork, Centering & Scaffolding for Sl No 9 : RCC Columns / Shaft (Slip Centering) in Volume-1 of page No.-111 (@70% of Finished Rate) ---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 4790.1 | 4790.1 | 5.4 | False | None | None | False | None | False | 25866.54 | 0 | 2381417 | 70805 | None | Vol-1 pg No.-111 | Additional for formwork, Centering & Scaffolding for Sl No 02 : Plinth Beams of Buildings in Volume-1 of page No.-111 (@50% of Finished Rate) ---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 3421.5 | 3421.5 | 8.05 | False | None | None | False | None | False | 27543.075 | 0 | 2381418 | 70805 | None | Vol-1 pg No.-112 | Additional for formwork, Centering & Scaffolding for Sl No 14 : RCC Beams, Lintels & Troughs of Aqueducts in Volume-1 of page No.-112 (@60% of Finished Rate) ---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 4105.8 | 4105.8 | 9.87 | False | None | None | False | None | False | 40524.246 | 0 | 2381419 | 70805 | None | Vol-1 pg No.-112 | Additional for formwork, Centering & Scaffolding for Sl No 19 : Chejjas, Canopy & Other Architectural projections of minor sections in Volume-1 of page No.-112 (@45% of Finished Rate) ---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 3079.35 | 3079.35 | 1.08 | False | None | None | False | None | False | 3325.698 | 0 | 2381420 | 70805 | None | Vol-1 pg No.-112 | Additional for formwork, Centering & Scaffolding for Sl No 15 : RCC Roof Slabs in Volume-1 of page No.-112 (@ 50% of Finished Rate) ---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 3421.5 | 3421.5 | 18.14 | False | None | None | False | None | False | 62066.01 | 0 | 2381421 | 70805 | None | Vol-1 pg No.-112 50 | Additional for formwork, Centering & Scaffolding for Sl No 16 :Staircase and other similar structures in Volume-1 of page No.-112 (@ 50% of Finished Rate) ---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 3421.5 | 3421.5 | 2.65 | False | None | None | False | None | False | 9066.975 | 0 | 2381422 | 70805 | None | Vol No-1 pg no-18 I No 2.11a | Steel Fabrication Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement
including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft
annealed steel wire and other ancilary operations complete as per drawing and technical specific ation.a)Buildings ---- Work should be carried out as per the direction of engineer incharge of work. | MT | 89457.0 | 89457.0 | 5.63 | False | None | None | False | None | False | 503642.91 | 0 | 2381423 | 70805 | None | Vol No-2 pg no-14 I No 6.8 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and
sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. ---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 7969.0 | 7969.0 | 42.68 | False | None | None | False | None | False | 340116.92 | 0 | 2381424 | 70805 | None | Vol No-2 pg no-14 I No 6.15 | Providing Half brick masonry with common burnt clay Non Modularbricks of class designation 3.5 in superstructure above plinth level upto floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer
incharge of work. ---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 1033.0 | 1033.0 | 7.92 | False | None | None | False | None | False | 8181.36 | 0 | 2381425 | 70805 | None | Vol No-2 pg no-41 I No 8.2.1 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 295.0 | 295.0 | 168.2 | False | None | None | False | None | False | 49619.0 | 0 | 2381426 | 70805 | None | Vol No-2 pg no-42 I No 8.8 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished
with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 371.0 | 371.0 | 295.96 | False | None | None | False | None | False | 109801.16 | 0 | 2381427 | 70805 | None | Vol No-2 pg no-64 I No 9.34 | Flooring with 25mm thick polished tandur blue stone slabs using cementmortar 1:6, 25mm thick over existing cement concrete bed or top of roof
laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing,
polishing complete as per specifications. ---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 1545.0 | 1545.0 | 136.86 | False | None | None | False | None | False | 211448.7 | 0 | 2381428 | 70805 | None | Vol No-2 pg no-86I No 11.34B | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat withapproved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. ---- Work should be carried out as per the direction of engineer incharge of work. | Kg | 183.0 | 183.0 | 323.19 | False | None | None | False | None | False | 59143.77 | 0 | 2381429 | 70805 | None | Vol No-2 pg no-81 I No 11.14.3.1 | Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm
thickness, including hinges, jamb, lock jamb, bead and if required angle thre shold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm,
pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer- in-charge: Profile E Fixing with adjustable lugs with split end tail to each jamb including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of theEngineer-in-Charge. ---- Work should be carried out as per the direction of engineer incharge of work. | m | 531.0 | 531.0 | 13.2 | False | None | None | False | None | False | 7009.2 | 0 | 2381430 | 70805 | None | Vol No-2 pg no-77 I No 11.5.1 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-inCharge ---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 4478.0 | 4478.0 | 5.04 | False | None | None | False | None | False | 22569.12 | 0 | 2381431 | 70805 | None | Vol No-2 pg no-109 I No 12.84 | Providing & fixing of 2-track 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6 PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets -grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 44mm width x 40mmheight with reinforcement of 1mm thickness and Sash with overall size of 27mm X 53mm with UPVCirections of the Engineer-in-Charge.honeycomb structure inside in lieu of GI reinforcement. Coextruded Glazing bead for fixing of glass shall be of size 9.5mm 21.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with Crescent Locks. Wall thickness of frame & sash shall be of 2 mm .Maximum possible size 1219mm 1219mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 5023.0 | 5023.0 | 8.64 | False | None | None | False | None | False | 43398.72 | 0 | 2381432 | 70805 | None | Vol No-2 pg no-50 I No 8.51 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 100.0 | 100.0 | 297.36 | False | None | None | False | None | False | 29736.0 | 0 | 2381433 | 70805 | None | Vol No-2 pg no-45 I No8.25 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions
of Engineer-in-charge. ---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 137.0 | 137.0 | 297.36 | False | None | None | False | None | False | 40738.32 | 0 | 2381434 | 70805 | None | Vol No-2 pg no-45 I No8.27 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give
an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface
even and sand paper smooth, cost of materials, labour complete as perspecifications and as per directions of Engineer-in-charge. ---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 53.0 | 53.0 | 295.95 | False | None | None | False | None | False | 15685.35 | 0 | 2381435 | 70805 | None | Vol No-2 pg no-45 I No8.28 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoro ughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper
smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 89.0 | 89.0 | 295.95 | False | None | None | False | None | False | 26339.55 | 0 | 2381436 | 70805 | None | Vol No-2 pg no-48 No8.40 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops
and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per
directions of Engineer-in-charge. ---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 115.0 | 115.0 | 28.11 | False | None | None | False | None | False | 3232.65 | 0 | 2381437 | 70805 | None | Vol No-2 pg no-49 I No8.49 | Lettering with black Japan paint of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning the
surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge ---- Work should be carried out as per the direction of engineer incharge of work. | cm | 4.0 | 4.0 | 4000.0 | False | None | None | False | None | False | 16000.0 | 0 | 2381438 | 70805 | None | Vol No-2 pg no-49 I No8.43 | Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade :Two coats on new work including
preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per
directions of Engineer-in-charge ---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 94.0 | 94.0 | 11.52 | False | None | None | False | None | False | 1082.88 | 0 | 2381439 | 70805 | None | Vol No-2 pg no-125 I no -13.48 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring
conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter ---- Work should be carried out as per the direction of engineer incharge of work. | m | 291.0 | 291.0 | 14.0 | False | None | None | False | None | False | 4074.0 | 0 |
| 1706788256000 | 0 | None | None | Buildings | 1 Construction of Two Class Rooms for Government Higher Primary School at Shagyoti Village Gadag Dist Tq (32.80 Lakhs) (Electrificaiton) | 49858.0 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2381440 | 70806 | None | Volume-6 PWD Part-1 (Page No.2 Item No.1.1.1) | Open Conduit System Concealed Conduit System :Supplying heavy gauge PVC conduit pipe mm dia mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary19/20mm dia 2mm thick ---- Work should be carried out as per the direction of engineer incharge of work. | Mtr | 69.0 | 69.0 | 30.0 | False | None | None | False | None | False | 2070.0 | 0 | 2381441 | 70806 | None | Volume-6 PWD Part-1 (Page No.2 Item No.1.1.2) | Concealed Conduit System :Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary25mm dia 2mm thick ---- Work should be carried out as per the direction of engineer incharge of work. | Mtr | 81.0 | 81.0 | 16.0 | False | None | None | False | None | False | 1296.0 | 0 | 2381442 | 70806 | None | Volume-6 PWD Part-1 (Page No.2 Item No.1.3.1) | Supplying heavy gauge PVC Conduit Pipe 25dia 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.19/20mm dia 2mm thick ---- Work should be carried out as per the direction of engineer incharge of work. | Mtr | 68.0 | 68.0 | 12.0 | False | None | None | False | None | False | 816.0 | 0 | 2381443 | 70806 | None | Volume-6 PWD Part-1 (Page No.2 Item No.1.3.2) | Supplying heavy gauge PVC Conduit Pipe 25dia 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.25mm dia 2mm thick ---- Work should be carried out as per the direction of engineer incharge of work. | Mtr | 79.0 | 79.0 | 12.0 | False | None | None | False | None | False | 948.0 | 0 | 2381444 | 70806 | None | Volume-6 PWD Part-1 (Page No.3Item No.1.9.2) | Supplying PVC/GI flexible conduit pipe .... mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of the pipe terminated completely25mm ---- Work should be carried out as per the direction of engineer incharge of work. | Mtr | 22.0 | 22.0 | 4.0 | False | None | None | False | None | False | 88.0 | 0 | 2381445 | 70806 | None | Volume-6 PWD Part-1 (Page No.5 Item No.2.2.1) | PSupplying and wiring adopting loop system in existing PVC Conduit/casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulatedcopper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box,the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Short point upto 3Mtr from tapping point to out let via switch box ---- Work should be carried out as per the direction of engineer incharge of work. | Point | 269.0 | 269.0 | 12.0 | False | None | None | False | None | False | 3228.0 | 0 | 2381446 | 70806 | None | Volume-6 PWD Part-1 (Page No.5 Item No.2.2.2) | Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch ---- Work should be carried out as per the direction of engineer incharge of work. | Point | 379.0 | 379.0 | 2.0 | False | None | None | False | None | False | 758.0 | 0 | 2381447 | 70806 | None | Volume-6 PWD Part-1 (Page No.5 Item No.2.2.3) | Long point above 6Mtr upto 10Mtr from tapping point to out let via switch box ---- Work should be carried out as per the direction of engineer incharge of work. | Point | 555.0 | 555.0 | 2.0 | False | None | None | False | None | False | 1110.0 | 0 | 2381448 | 70806 | None | 2.3.2Volume6 PWD Part-1 (Page No.5 Item No.2.3.2) | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade,1.5 SQMM multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP. ---- Work should be carried out as per the direction of engineer incharge of work. | Mtr | 26.0 | 26.0 | 60.0 | False | None | None | False | None | False | 1560.0 | 0 | 2381449 | 70806 | None | Volume-6 PWD Part-1 (Page No.5 Item No.2.3.3) | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade,2.5 SQMM multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP. ---- Work should be carried out as per the direction of engineer incharge of work. | Mtr | 42.0 | 42.0 | 70.0 | False | None | None | False | None | False | 2940.0 | 0 | 2381450 | 70806 | None | Volume-6 PWD Part-1 (Page No.5 Item No.2.3.4) | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade,4 SQMM multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP. ---- Work should be carried out as per the direction of engineer incharge of work. | Mtr | 63.0 | 63.0 | 40.0 | False | None | None | False | None | False | 2520.0 | 0 | 2381451 | 70806 | None | Volume-6 PWD Part-1 (Page No.8 Item No.3.4.1) | Supplying and flush mounting powder coated / galvanized metal box size 1-2 way suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ---- Work should be carried out as per the direction of engineer incharge of work. | Each | 138.0 | 138.0 | 4.0 | False | None | None | False | None | False | 552.0 | 0 | 2381452 | 70806 | None | Volume-6 PWD Part-1 (Page No.8 Item No.3.4.3) | Supplying and flush mounting powder coated / galvanized metal box size 4-5way suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ---- Work should be carried out as per the direction of engineer incharge of work. | Each | 177.0 | 177.0 | 2.0 | False | None | None | False | None | False | 354.0 | 0 | 2381453 | 70806 | None | Volume-6 PWD Part-1 (Page No.8 Item No.3.4.5) | Supplying and flush mounting powder coated / galvanized metal box size 8way suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ---- Work should be carried out as per the direction of engineer incharge of work. | Each | 261.0 | 261.0 | 2.0 | False | None | None | False | None | False | 522.0 | 0 | 2381454 | 70806 | None | Volume-6 PWD Part-1 (Page No.8 Item No.3.4.6) | Supplying and flush mounting powder coated / galvanized metal box size10-12way suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ---- Work should be carried out as per the direction of engineer incharge of work. | Each | 319.0 | 319.0 | 2.0 | False | None | None | False | None | False | 638.0 | 0 | 2381455 | 70806 | None | Volume-6 PWD Part-1 (Page No.8 Item No.3.5.2) | Supplying and fixing superior quality 3Mudular modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal box. ---- Work should be carried out as per the direction of engineer incharge of work. | Each | 161.0 | 161.0 | 2.0 | False | None | None | False | None | False | 322.0 | 0 | 2381456 | 70806 | None | Volume-6 PWD Part-1 (Page No.8 Item No.3.5.3) | Supplying and fixing superior quality 4Mudular modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal box. ---- Work should be carried out as per the direction of engineer incharge of work. | Each | 175.0 | 175.0 | 2.0 | False | None | None | False | None | False | 350.0 | 0 | 2381457 | 70806 | None | Volume-6 PWD Part-1 (Page No.5 Item No.3.5.5) | Supplying and fixing superior quality 8 modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalbox. ---- Work should be carried out as per the direction of engineer incharge of work. | Each | 284.0 | 284.0 | 2.0 | False | None | None | False | None | False | 568.0 | 0 | 2381458 | 70806 | None | Volume-6 PWD Part-1 (Page No.8 Item No.3.5.6) | Supplying and fixing superior quality 10-12Mudular modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalbox. ---- Work should be carried out as per the direction of engineer incharge of work. | Each | 344.0 | 344.0 | 2.0 | False | None | None | False | None | False | 688.0 | 0 | 2381459 | 70806 | None | Volume-6 PWD Part-1 (Page No.9 Item No.3.6.1) | Supplying and fixing of 6Amps 0ne way modular switch on existing modular switch plate as per IS 3854 and IS 1293. ---- Work should be carried out as per the direction of engineer incharge of work. | Each | 102.0 | 102.0 | 18.0 | False | None | None | False | None | False | 1836.0 | 0 | 2381460 | 70806 | None | Volume-6 PWD Part-1 (Page No.9 Item No.3.6.3) | Supplying and fixing of 6Amps 3way modular Socketc on existing modular switch plate as per IS 3854 and IS 1293. ---- Work should be carried out as per the direction of engineer incharge of work. | Each | 171.0 | 171.0 | 8.0 | False | None | None | False | None | False | 1368.0 | 0 | 2381461 | 70806 | None | Volume-6 PWD Part-1 (Page No.9 Item No.3.6.4) | Supplying and fixing of modular stepped electronic fan regulator on existing modular switch plate as per and IS 1293. ---- Work should be carried out as per the direction of engineer incharge of work. | Each | 357.0 | 357.0 | 4.0 | False | None | None | False | None | False | 1428.0 | 0 | 2381462 | 70806 | None | Volume-6 PWD Part-1 (Page No.9 Item No.3.6.7) | Supplying and fixing of 16Amps 0ne way modular switch on existing modular switch plate as per IS 3854 and IS 1293. ---- Work should be carried out as per the direction of engineer incharge of work. | Each | 180.0 | 180.0 | 2.0 | False | None | None | False | None | False | 360.0 | 0 | 2381463 | 70806 | None | Volume-6 PWD Part-1 (Page No.9 Item No.3.6.9) | Supplying and fixing of32Amps modular DP Switch on existing modular switch plate as per IS 3854 and IS 1293. ---- Work should be carried out as per the direction of engineer incharge of work. | Each | 326.0 | 326.0 | 2.0 | False | None | None | False | None | False | 652.0 | 0 | 2381464 | 70806 | None | Volume-6 PWD Part-1 (Page No.9 Item No.3.6.10) | Supplying and fixing of6/16amps modular Universal Socket on existing modular switch plate as per IS 3854 and IS 1293. ---- Work should be carried out as per the direction of engineer incharge of work. | Each | 236.0 | 236.0 | 2.0 | False | None | None | False | None | False | 472.0 | 0 | 2381465 | 70806 | None | Volume-6 PWD Part-1 (Page No.10 Item No.3.14.6) | Supplying and fixing of 6Amps pendent holder on existing board. ---- Work should be carried out as per the direction of engineer incharge of work. | Each | 71.0 | 71.0 | 4.0 | False | None | None | False | None | False | 284.0 | 0 | 2381466 | 70806 | None | Volume-6 PWD Part-1 (Page No.14 Item No.5.7.3) | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers.63amps ---- Work should be carried out as per the direction of engineer incharge of work. | Each | 401.0 | 401.0 | 2.0 | False | None | None | False | None | False | 802.0 | 0 | 2381467 | 70806 | None | Volume-6 PWD Part-1 (Page No.30 Item No.6.3.1) | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm) Economy model ---- Work should be carried out as per the direction of engineer incharge of work. | Each | 2984.0 | 2984.0 | 4.0 | False | None | None | False | None | False | 11936.0 | 0 | 2381468 | 70806 | None | Volume-6 PWD Part-1 (Page No.43 Item No.11.3.2) | LED Indoor Supplying of 1x4' feet - LED PVC Square Batten 20/22W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50Hz & Power factor 0.9 along with CE approved drivers. 2 years Warranty against any manufacturing defect working under standard electrical condition ---- Work should be carried out as per the direction of engineer incharge of work. | Each | 690.0 | 690.0 | 4.0 | False | None | None | False | None | False | 2760.0 | 0 | 2381469 | 70806 | None | Volume-6 PWD Part-1 (Page No.47 Item No.11.11.4) | Supplying & fixing of retrofit type - LED bulb ...... W with OPAL acrylic
diffuser comprising of LED source with CCT 6500 degree K, CRI 70%.
efficacy 80 lumen per W, life 25000 burning hours and Compliance to IS
10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic
driver integrated in the system, with PF 0.95, power loss should 5% of
lamp Wage., short circuit & open circuit protection to be integrated in the
circuit, THD less than 20%, Life as per LM 79. The operating input voltage
should be between 130 to 275 V. BIS Approved and Tested by
NABL/CPRI accredited laboratory with 2 years Warranty against any
manufacturing defect working under standard electrical condition. ---- Work should be carried out as per the direction of engineer incharge of work. | Each | 154.0 | 154.0 | 4.0 | False | None | None | False | None | False | 616.0 | 0 | 2381470 | 70806 | None | Volume-6 PWD Part-1 (Page No.56 Item No.13.7.1) | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. ---- Work should be carried out as per the direction of engineer incharge of work. | Each | 122.0 | 122.0 | 8.0 | False | None | None | False | None | False | 976.0 | 0 | 2381471 | 70806 | None | Volume-6 PWD Part-1 (Page No.57 Item No.13.10) | Fixing a ceiling / Wall mounting fan of all capacities and all types to
the existing 'S'' hook with fan regulator to the existing board together
with supplying and fixing 5 A. ceiling rose, necessary length of
23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. ---- Work should be carried out as per the direction of engineer incharge of work. | Each | 171.0 | 171.0 | 4.0 | False | None | None | False | None | False | 684.0 | 0 | 2381472 | 70806 | None | ESCOM SR 2023-24 Item No.51.01 Page No.22) | Grounding Material
GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long,
3.2 mm thick with bolt, nut, GI Strips and washer
complete Minimum Weight of GI Pipe: 7.3 Kg (ESCOM SR 2023-24 Item No.51.01 Page No.22) ---- Work should be carried out as per the direction of engineer incharge of work. | Each | 743.0 | 743.0 | 2.0 | False | None | None | False | None | False | 1486.0 | 0 | 2381473 | 70806 | None | ESCOM SR 2023-24 Item No.51.02 Page No.22) | Grounding Material
Good Quality well burnt Charcoal for grounding
purposes packed in non returnable gunny bag of 30 Kg
each (BESCOM Part-III 11 KV Materials Item No.54.02 Page No.17) ---- Work should be carried out as per the direction of engineer incharge of work. | Each | 676.0 | 676.0 | 2.0 | False | None | None | False | None | False | 1352.0 | 0 | 2381474 | 70806 | None | 23-24 Item No.1.6.1 ordinary soil Page No.43) | Digging of Pit for providing GI Pipe type Earthing Ordinary Soil (ESCOM SR 2023-24 Item No.1.6.1 ordinary soil Page No.43) ---- Work should be carried out as per the direction of engineer incharge of work. | Per Pit | 759.0 | 759.0 | 2.0 | False | None | None | False | None | False | 1518.0 | 0 |
| 1706788256000 | 0 | None | None | Buildings | 2 Construction of Two Class Rooms for Government Higher Primary School at Chikkahandigol Village Gadag Dist/Tq (Rs.27.80) Lakhs | 2305535.75 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2381475 | 70807 | None | Vol No-1 pg no-08I No 1.12 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurten ances required to complete the work. ---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 95.0 | 95.0 | 48.6 | False | None | None | False | None | False | 4617.0 | 0 | 2381476 | 70807 | None | Vol No-1 pg no-08 I No 1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the In all kinds of soils Depth upto 3 m ---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 102.0 | 102.0 | 182.92 | False | None | None | False | None | False | 18657.84 | 0 | 2381477 | 70807 | None | Vol No-2 pg no-05I No 4.1 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with
Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage
charges of machinery, complete as per specific ations. ---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 118.0 | 118.0 | 112.78 | False | None | None | False | None | False | 13308.04 | 0 | 2381478 | 70807 | None | Vol No-2 pg no 11 I No 1.23 | Providing and Filling in foundation with granite / trap broken metal 100mm. And down size & with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift complete as per specifications. ---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 2682.0 | 2682.0 | 21.3 | False | None | None | False | None | False | 57126.6 | 0 | 2381479 | 70807 | None | Vol No-1 pg no-15 I No 2.1.3 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggre gates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of
machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates ---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 5989.0 | 5989.0 | 30.58 | False | None | None | False | None | False | 183143.62 | 0 | 2381480 | 70807 | None | Vol No-1 pg no-15I No 2.2.3 | Providing and laying in position Cement Concrete for all Foundation works.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished
layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specification s.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 6336.0 | 6336.0 | 26.9 | False | None | None | False | None | False | 170438.4 | 0 | 2381481 | 70807 | None | Vol-1 pg No.-111 (8 Percentage ) | Additional for formwork, Centering & Scaffolding for Sl No 1 a: Foundation upto plinth Isolated As per Appendix-I in Volume-1 of page No.-111 (@8% of Finished Rate) ---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 506.88 | 506.88 | 26.9 | False | None | None | False | None | False | 13635.072 | 0 | 2381482 | 70807 | None | Vol No-1 pg no-16I No 2.3.2 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/
basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 6480.0 | 6480.0 | 11.45 | False | None | None | False | None | False | 74196.0 | 0 | 2381483 | 70807 | None | Vol-1 pg No.-111 70 | Additional for formwork, Centering & Scaffolding for Sl No 8: Columns & Piers As per Appendix-I in Volume-1 of page No.-111 (@70% of Finished Rate) ---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 4536.0 | 4536.0 | 2.08 | False | None | None | False | None | False | 9434.88 | 0 | 2381484 | 70807 | None | Vol-1 pg No.-112 | Additional for formwork, Centering & Scaffolding for Sl No 2: Earth retaining structure drainages As per Appendix-I in Volume-1 of page No.-112(@10% of Finished Rate) ---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 648.0 | 648.0 | 9.37 | False | None | None | False | None | False | 6071.76 | 0 | 2381485 | 70807 | None | Vol No-1 pg no-7I No 1.8 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. If the height of embankment construction is more than 1.50 m add 5% per for every 1.50 m height or part there off ---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 474.0 | 474.0 | 247.65 | False | None | None | False | None | False | 117386.1 | 0 | 2381486 | 70807 | None | Vol No-1 pg no-16I No2.4.1 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works &
other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS
Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregates ---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 6404.0 | 6404.0 | 3.09 | False | None | None | False | None | False | 19788.36 | 0 | 2381487 | 70807 | None | Vol No-1 pg no-16 I No 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse
aggrgates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The
cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications .M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 6843.0 | 6843.0 | 35.76 | False | None | None | False | None | False | 244705.68 | 0 | 2381488 | 70807 | None | Vol-1 pg No.-111 | Additional for formwork, Centering & Scaffolding for Sl No 8: Columns & Piers As per Appendix-I in Volume-1 of page No.-111 (@70% of Finished Rate) ---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 4790.1 | 4790.1 | 5.0 | False | None | None | False | None | False | 23950.5 | 0 | 2381489 | 70807 | None | Vol-1 pg No.-111 | Additional for formwork, Centering & Scaffolding for Sl No 12 : plinth beam As per corrigendam 3 Appendix-I in Volume-1 of page No.-111 (@50% of Finished Rate) ---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 3421.5 | 3421.5 | 7.02 | False | None | None | False | None | False | 24018.93 | 0 | 2381490 | 70807 | None | Vol-1 pg No.-112 | Additional for formwork, Centering & Scaffolding for Sl No 12 : beam & lintels As per Appendix-I in Volume-1 of page No.-112 (@60% of Finished Rate) ---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 4105.8 | 4105.8 | 8.56 | False | None | None | False | None | False | 35145.648 | 0 | 2381491 | 70807 | None | Vol-1 pg No.-112 | Additional for formwork, Centering & Scaffolding for Sl No 20 : Chejjas, Canopy & Other Architectural projections of minor sections As per Appendix-I in Volume-1 of page No.-112 (@45% of Finished Rate) ---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 3079.35 | 3079.35 | 1.08 | False | None | None | False | None | False | 3325.698 | 0 | 2381492 | 70807 | None | Vol-1 pg No.-112 | Additional for formwork, Centering & Scaffolding for Sl No 13 : Roof straight As per corrigendum Appendix-I in Volume-1 of page No.-112 (@ 50% of Finished Rate) ---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 3421.5 | 3421.5 | 14.1 | False | None | None | False | None | False | 48243.15 | 0 | 2381493 | 70807 | None | Vol No-1 pg no-18 I No 2.11a | Steel Fabrication Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement
including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft
annealed steel wire and other ancilary operations complete as per drawing and technical specific ation.a)Buildings ---- Work should be carried out as per the direction of engineer incharge of work. | MT | 89457.0 | 89457.0 | 4.87 | False | None | None | False | None | False | 435655.59 | 0 | 2381494 | 70807 | None | Vol No-2 pg no-14 I No 6.8 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and
sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. ---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 7969.0 | 7969.0 | 31.04 | False | None | None | False | None | False | 247357.76 | 0 | 2381495 | 70807 | None | Vol No-2 pg no-14 I No 6.15 | Providing Half brick masonry with common burnt clay Non Modularbricks of class designation 3.5 in superstructure above plinth level upto floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer
incharge of work. ---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 1033.0 | 1033.0 | 9.36 | False | None | None | False | None | False | 9668.88 | 0 | 2381496 | 70807 | None | Vol No-2 pg no-41 I No 8.2.1 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 295.0 | 295.0 | 137.26 | False | None | None | False | None | False | 40491.7 | 0 | 2381497 | 70807 | None | Vol No-2 pg no-42 I No 8.8 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished
with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 371.0 | 371.0 | 229.06 | False | None | None | False | None | False | 84981.26 | 0 | 2381498 | 70807 | None | Vol No-2 pg no-64 No 9.34 | Flooring with 25mm thick polished tandur blue stone slabs using cementmortar 1:6, 25mm thick over existing cement concrete bed or top of roof
laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing,
polishing complete as per specifications. ---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 1545.0 | 1545.0 | 109.2 | False | None | None | False | None | False | 168714.0 | 0 | 2381499 | 70807 | None | Vol No-2 pg no-86I No 11.34B | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat withapproved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. ---- Work should be carried out as per the direction of engineer incharge of work. | Kg | 183.0 | 183.0 | 338.94 | False | None | None | False | None | False | 62026.02 | 0 | 2381500 | 70807 | None | Vol No-2 pg no-81 I No 11.14.3.1 | Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm
thickness, including hinges, jamb, lock jamb, bead and if required angle thre shold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm,
pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer- in-charge: Profile E Fixing with adjustable lugs with split end tail to each jamb including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of theEngineer-in-Charge. ---- Work should be carried out as per the direction of engineer incharge of work. | m | 531.0 | 531.0 | 13.2 | False | None | None | False | None | False | 7009.2 | 0 | 2381501 | 70807 | None | Vol No-2 pg no-77 I No 11.5.1 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-inCharge ---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 4478.0 | 4478.0 | 5.04 | False | None | None | False | None | False | 22569.12 | 0 | 2381502 | 70807 | None | Vol No-2 pg no-79 I No 11.11.1 | Providing & fixing of 2-track 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6 PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets -grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 44mm width x 40mmheight with reinforcement of 1mm thickness and Sash with overall size of 27mm X 53mm with UPVCirections of the Engineer-in-Charge.honeycomb structure inside in lieu of GI reinforcement. Coextruded Glazing bead for fixing of glass shall be of size 9.5mm x 21.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with Crescent Locks. Wall thickness of frame & sash shall be of 2 mm .Maximum possible size 1219mm x 1219mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 5023.0 | 5023.0 | 8.64 | False | None | None | False | None | False | 43398.72 | 0 | 2381503 | 70807 | None | Vol No-2 pg no-50 I No 8.51 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 100.0 | 100.0 | 240.04 | False | None | None | False | None | False | 24004.0 | 0 | 2381504 | 70807 | None | Vol No-2 pg no-45 I No8.25 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions
of Engineer-in-charge. ---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 137.0 | 137.0 | 240.04 | False | None | None | False | None | False | 32885.48 | 0 | 2381505 | 70807 | None | Vol No-2 pg no-45 I No8.27 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give
an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface
even and sand paper smooth, cost of materials, labour complete as perspecifications and as per directions of Engineer-in-charge. ---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 53.0 | 53.0 | 229.06 | False | None | None | False | None | False | 12140.18 | 0 | 2381506 | 70807 | None | Vol No-2 pg no-45 No8.28 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoro ughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper
smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 89.0 | 89.0 | 229.06 | False | None | None | False | None | False | 20386.34 | 0 | 2381507 | 70807 | None | Vol No-2 pg no-48 No8.40 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops
and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per
directions of Engineer-in-charge. ---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 115.0 | 115.0 | 28.86 | False | None | None | False | None | False | 3318.9 | 0 | 2381508 | 70807 | None | Vol No-2 pg no-49 No8.49 | Lettering with black Japan paint of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning the
surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge ---- Work should be carried out as per the direction of engineer incharge of work. | cm | 4.0 | 4.0 | 4000.0 | False | None | None | False | None | False | 16000.0 | 0 | 2381509 | 70807 | None | Vol No-2 pg no-49 I No8.43 | Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade :Two coats on new work including
preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per
directions of Engineer-in-charge ---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 94.0 | 94.0 | 17.28 | False | None | None | False | None | False | 1624.32 | 0 | 2381510 | 70807 | None | Vol No-2 pg no-125 I no -13.48 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring
conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter ---- Work should be carried out as per the direction of engineer incharge of work. | m | 291.0 | 291.0 | 21.0 | False | None | None | False | None | False | 6111.0 | 0 |
| 1706788256000 | 0 | None | None | Buildings | Construction of Two Class Rooms for Government Higher Primary School at Chikkahandigol Village Gadag DistTq (ELECTRIFICATION | 49858.0 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2381511 | 70808 | None | Volume-6 PWD Part-1 (Page No.2 Item No.1.1.1) | Open Conduit System Concealed Conduit System :Supplying heavy gauge PVC conduit pipe mm dia mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary19/20mm dia 2mm thick ---- Work should be carried out as per the direction of engineer incharge of work. | Mtr | 69.0 | 69.0 | 30.0 | False | None | None | False | None | False | 2070.0 | 0 | 2381512 | 70808 | None | Volume-6 PWD Part-1 (Page No.2 Item No.1.1.2) | Concealed Conduit System :Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary25mm dia 2mm thick ---- Work should be carried out as per the direction of engineer incharge of work. | Mtr | 81.0 | 81.0 | 16.0 | False | None | None | False | None | False | 1296.0 | 0 | 2381513 | 70808 | None | Volume-6 PWD Part-1 (Page No.2 Item No.1.3.1) | Supplying heavy gauge PVC Conduit Pipe 25dia 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.19/20mm dia 2mm thick ---- Work should be carried out as per the direction of engineer incharge of work. | Mtr | 68.0 | 68.0 | 12.0 | False | None | None | False | None | False | 816.0 | 0 | 2381514 | 70808 | None | Volume-6 PWD Part-1 (Page No.2 Item No.1.3.2) | Supplying heavy gauge PVC Conduit Pipe 25dia 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.25mm dia 2mm thick ---- Work should be carried out as per the direction of engineer incharge of work. | Mtr | 79.0 | 79.0 | 12.0 | False | None | None | False | None | False | 948.0 | 0 | 2381515 | 70808 | None | Volume-6 PWD Part-1 (Page No.3Item No.1.9.2) | Supplying PVC/GI flexible conduit pipe .... mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of the pipe terminated completely25mm ---- Work should be carried out as per the direction of engineer incharge of work. | Mtr | 22.0 | 22.0 | 4.0 | False | None | None | False | None | False | 88.0 | 0 | 2381516 | 70808 | None | Volume-6 PWD Part-1 (Page No.5 Item No.2.2.1) | Supplying and wiring adopting loop system in existing PVC Conduit/casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulatedcopper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box,the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Short point upto 3Mtr from tapping point to out let via switch box ---- Work should be carried out as per the direction of engineer incharge of work. | Point | 269.0 | 269.0 | 12.0 | False | None | None | False | None | False | 3228.0 | 0 | 2381517 | 70808 | None | Volume-6 PWD Part-1 (Page No.5 Item No.2.2.2) | Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch ---- Work should be carried out as per the direction of engineer incharge of work. | Point | 379.0 | 379.0 | 2.0 | False | None | None | False | None | False | 758.0 | 0 | 2381518 | 70808 | None | Volume-6 PWD Part-1 (Page No.5 Item No.2.2.3) | Long point above 6Mtr upto 10Mtr from tapping point to out let via switch box ---- Work should be carried out as per the direction of engineer incharge of work. | Point | 555.0 | 555.0 | 2.0 | False | None | None | False | None | False | 1110.0 | 0 | 2381519 | 70808 | None | 2.3.2Volume-6 PWD Part-1 (Page No.5 Item No.2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade,1.5 SQMM multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP. ---- Work should be carried out as per the direction of engineer incharge of work. | Mtr | 26.0 | 26.0 | 60.0 | False | None | None | False | None | False | 1560.0 | 0 | 2381520 | 70808 | None | Volume-6 PWD Part-1 (Page No.5 Item No.2.3.3) | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade,2.5 SQMM multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP. ---- Work should be carried out as per the direction of engineer incharge of work. | Mtr | 42.0 | 42.0 | 70.0 | False | None | None | False | None | False | 2940.0 | 0 | 2381521 | 70808 | None | Volume-6 PWD Part-1 (Page No.5 Item No.2.3.4) | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade,4 SQMM multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP. ---- Work should be carried out as per the direction of engineer incharge of work. | Mtr | 63.0 | 63.0 | 40.0 | False | None | None | False | None | False | 2520.0 | 0 | 2381522 | 70808 | None | Volume-6 PWD Part-1 (Page No.8 Item No.3.4.1) | Supplying and flush mounting powder coated / galvanized metal box size 1-2 way suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ---- Work should be carried out as per the direction of engineer incharge of work. | Each | 138.0 | 138.0 | 4.0 | False | None | None | False | None | False | 552.0 | 0 | 2381523 | 70808 | None | Volume-6 PWD Part-1 (Page No.8 Item No.3.4.3) | Supplying and flush mounting powder coated / galvanized metal box size 4-5way suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ---- Work should be carried out as per the direction of engineer incharge of work. | Each | 177.0 | 177.0 | 2.0 | False | None | None | False | None | False | 354.0 | 0 | 2381524 | 70808 | None | Volume-6 PWD Part-1 (Page No.8 Item No.3.4.5) | Supplying and flush mounting powder coated / galvanized metal box size 8way suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ---- Work should be carried out as per the direction of engineer incharge of work. | Each | 261.0 | 261.0 | 2.0 | False | None | None | False | None | False | 522.0 | 0 | 2381525 | 70808 | None | Volume-6 PWD Part-1 (Page No.8 Item No.3.4.6) | Supplying and flush mounting powder coated / galvanized metal box size10-12way suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ---- Work should be carried out as per the direction of engineer incharge of work. | Each | 319.0 | 319.0 | 2.0 | False | None | None | False | None | False | 638.0 | 0 | 2381526 | 70808 | None | Volume-6 PWD Part-1 (Page No.8 Item No.3.5.2) | Supplying and fixing superior quality 3Mudular modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal box. ---- Work should be carried out as per the direction of engineer incharge of work. | Each | 161.0 | 161.0 | 2.0 | False | None | None | False | None | False | 322.0 | 0 | 2381527 | 70808 | None | Volume-6 PWD Part-1 (Page No.8 Item No.3.5.3) | Supplying and fixing superior quality 4Mudular modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal box. ---- Work should be carried out as per the direction of engineer incharge of work. | Each | 175.0 | 175.0 | 2.0 | False | None | None | False | None | False | 350.0 | 0 | 2381528 | 70808 | None | Volume-6 PWD Part-1 (Page No.5 Item No.3.5.5) | Supplying and fixing superior quality 8 modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalbox. ---- Work should be carried out as per the direction of engineer incharge of work. | Each | 284.0 | 284.0 | 2.0 | False | None | None | False | None | False | 568.0 | 0 | 2381529 | 70808 | None | Volume-6 PWD Part-1 (Page No.8 Item No.3.5.6) | Supplying and fixing superior quality 10-12Mudular modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalbox. ---- Work should be carried out as per the direction of engineer incharge of work. | Each | 344.0 | 344.0 | 2.0 | False | None | None | False | None | False | 688.0 | 0 | 2381530 | 70808 | None | Volume-6 PWD Part-1 (Page No.9 Item No.3.6.1) | Supplying and fixing of 6Amps 0ne way modular switch on existing modular switch plate as per IS 3854 and IS 1293. ---- Work should be carried out as per the direction of engineer incharge of work. | Each | 102.0 | 102.0 | 18.0 | False | None | None | False | None | False | 1836.0 | 0 | 2381531 | 70808 | None | Volume-6 PWD Part-1 (Page No.9 Item No.3.6.3) | Supplying and fixing of 6Amps 3way modular Socketc on existing modular switch plate as per IS 3854 and IS 1293. ---- Work should be carried out as per the direction of engineer incharge of work. | Each | 171.0 | 171.0 | 8.0 | False | None | None | False | None | False | 1368.0 | 0 | 2381532 | 70808 | None | Volume-6 PWD Part-1 (Page No.9 Item No.3.6.4) | Supplying and fixing of modular stepped electronic fan regulator on existing modular switch plate as per and IS 1293. ---- Work should be carried out as per the direction of engineer incharge of work. | Each | 357.0 | 357.0 | 4.0 | False | None | None | False | None | False | 1428.0 | 0 | 2381533 | 70808 | None | Volume-6 PWD Part-1 (Page No.9 Item No.3.6.7) | Supplying and fixing of 16Amps 0ne way modular switch on existing modular switch plate as per IS 3854 and IS 1293. ---- Work should be carried out as per the direction of engineer incharge of work. | Each | 180.0 | 180.0 | 2.0 | False | None | None | False | None | False | 360.0 | 0 | 2381534 | 70808 | None | Volume-6 PWD Part-1 (Page No.9 Item No.3.6.9) | Supplying and fixing of32Amps modular DP Switch on existing modular switch plate as per IS 3854 and IS 1293. ---- Work should be carried out as per the direction of engineer incharge of work. | Each | 326.0 | 326.0 | 2.0 | False | None | None | False | None | False | 652.0 | 0 | 2381535 | 70808 | None | Volume-6 PWD Part-1 (Page No.9 Item No.3.6.10) | Supplying and fixing of6/16amps modular Universal Socket on existing modular switch plate as per IS 3854 and IS 1293. ---- Work should be carried out as per the direction of engineer incharge of work. | Each | 236.0 | 236.0 | 2.0 | False | None | None | False | None | False | 472.0 | 0 | 2381536 | 70808 | None | Volume-6 PWD Part-1 (Page No.10 Item No.3.14.6) | Supplying and fixing of 6Amps pendent holder on existing board. ---- Work should be carried out as per the direction of engineer incharge of work. | Each | 71.0 | 71.0 | 4.0 | False | None | None | False | None | False | 284.0 | 0 | 2381537 | 70808 | None | Volume-6 PWD Part-1 (Page No.14 Item No.5.7.3) | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers.63amps ---- Work should be carried out as per the direction of engineer incharge of work. | Each | 401.0 | 401.0 | 2.0 | False | None | None | False | None | False | 802.0 | 0 | 2381538 | 70808 | None | Volume-6 PWD Part-1 (Page No.30 Item No.6.3.1) | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm) Economy model ---- Work should be carried out as per the direction of engineer incharge of work. | Each | 2984.0 | 2984.0 | 4.0 | False | None | None | False | None | False | 11936.0 | 0 | 2381539 | 70808 | None | Volume-6 PWD Part-1 (Page No.43 Item No.11.3.2) | LED Indoor Supplying of 1x4' feet - LED PVC Square Batten 20/22W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50Hz & Power factor 0.9 along with CE approved drivers. 2 years Warranty against any manufacturing defect working under standard electrical condition ---- Work should be carried out as per the direction of engineer incharge of work. | Each | 690.0 | 690.0 | 4.0 | False | None | None | False | None | False | 2760.0 | 0 | 2381540 | 70808 | None | Volume6 PWD Part-1 (Page No.47 Item No.11.11.4) | Supplying & fixing of retrofit type LED bulb . W with OPAL acrylicdiffuser comprising of LED source with CCT 6500 degree K, CRI 7.
efficacy 80 lumen per W, life 25000 burning hours and Compliance to IS
10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic
driver integrated in the system, with PF 0.95, power loss should 5 of
lamp Wage., short circuit & open circuit protection to be integrated in the
circuit, THD less than 20%, Life as per LM 79. The operating input voltage
should be between 130 to 275 V. BIS Approved and Tested by
NABLCPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. ---- Work should be carried out as per the direction of engineer incharge of work. | Each | 154.0 | 154.0 | 4.0 | False | None | None | False | None | False | 616.0 | 0 | 2381541 | 70808 | None | Volume-6 PWD Part-1 (Page No.56 Item No.13.7.1) | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. ---- Work should be carried out as per the direction of engineer incharge of work. | Each | 122.0 | 122.0 | 8.0 | False | None | None | False | None | False | 976.0 | 0 | 2381542 | 70808 | None | Volume-6 PWD Part-1 (Page No.57 Item No.13.10) | Fixing a ceiling / Wall mounting fan of all capacities and all types to
the existing 'S'' hook with fan regulator to the existing board together
with supplying and fixing 5 A. ceiling rose, necessary length of
23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. ---- Work should be carried out as per the direction of engineer incharge of work. | Each | 171.0 | 171.0 | 4.0 | False | None | None | False | None | False | 684.0 | 0 | 2381543 | 70808 | None | ESCOM SR 2023-24 Item No.51.01 Page No.22) | Grounding Material
GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long,
3.2 mm thick with bolt, nut, GI Strips and washer
complete Minimum Weight of GI Pipe: 7.3 Kg (ESCOM SR 2023-24 Item No.51.01 Page No.22) ---- Work should be carried out as per the direction of engineer incharge of work. | Each | 743.0 | 743.0 | 2.0 | False | None | None | False | None | False | 1486.0 | 0 | 2381544 | 70808 | None | ESCOM SR 2023-24 Item No.51.02 Page No.22) | Grounding Material
Good Quality well burnt Charcoal for grounding
purposes packed in non returnable gunny bag of 30 Kg
each (BESCOM Part-III 11 KV Materials Item No.54.02 Page No.17) ---- Work should be carried out as per the direction of engineer incharge of work. | Each | 676.0 | 676.0 | 2.0 | False | None | None | False | None | False | 1352.0 | 0 | 2381545 | 70808 | None | ESCOM SR 202324 Item No.1.6.1 ordinary soil Pg.43 | Digging of Pit for providing GI Pipe type Earthing Ordinary Soil (ESCOM SR 2023-24 Item No.1.6.1 ordinary soil Page No.43) ---- Work should be carried out as per the direction of engineer incharge of work. | Per Pit | 759.0 | 759.0 | 2.0 | False | None | None | False | None | False | 1518.0 | 0 |
| 1706788256000 | 0 | None | None | Buildings | Construction of Two Class Rooms for Government Higher Primary School at Madaganur Village Gadag Dist/Tq (27.80 Lakhs | 2305535.75 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2381546 | 70809 | None | Vol No-1 pg no-08I No 1.12 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurten ances required to complete the work. ---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 95.0 | 95.0 | 48.6 | False | None | None | False | None | False | 4617.0 | 0 | 2381547 | 70809 | None | Vol No-1 pg no-08I No 1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the In all kinds of soils Depth upto 3 m ---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 102.0 | 102.0 | 182.92 | False | None | None | False | None | False | 18657.84 | 0 | 2381548 | 70809 | None | Vol No-2 pg no-05I No 4.1 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with
Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage
charges of machinery, complete as per specific ations. ---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 118.0 | 118.0 | 112.78 | False | None | None | False | None | False | 13308.04 | 0 | 2381549 | 70809 | None | Vol No-2 pg no 11I No 1.23 | Providing and Filling in foundation with granite / trap broken metal 100mm. And down size & with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift complete as per specifications. ---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 2682.0 | 2682.0 | 21.3 | False | None | None | False | None | False | 57126.6 | 0 | 2381550 | 70809 | None | Vol No-1 pg no-15I No 2.1.3 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggre gates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of
machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates ---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 5989.0 | 5989.0 | 30.58 | False | None | None | False | None | False | 183143.62 | 0 | 2381551 | 70809 | None | Vol No-1 pg no-15I No 2.2.3 | Providing and laying in position Cement Concrete for all Foundation works.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished
layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specification s.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 6336.0 | 6336.0 | 26.9 | False | None | None | False | None | False | 170438.4 | 0 | 2381552 | 70809 | None | Vol-1 pg No.-111 (8 Percentage ) | Additional for formwork, Centering & Scaffolding for Sl No 1 a: Foundation upto plinth Isolated As per Appendix-I in Volume-1 of page No.-111 (@8% of Finished Rate) ---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 506.88 | 506.88 | 26.9 | False | None | None | False | None | False | 13635.072 | 0 | 2381553 | 70809 | None | Vol No-1 pg no-16I No 2.3.2 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/
basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 6480.0 | 6480.0 | 11.45 | False | None | None | False | None | False | 74196.0 | 0 | 2381554 | 70809 | None | Vol-1 pg No.-111 70 percentage | Additional for formwork, Centering & Scaffolding for Sl No 8: Columns & Piers As per Appendix-I in Volume-1 of page No.-111 (@70% of Finished Rate) ---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 4536.0 | 4536.0 | 2.08 | False | None | None | False | None | False | 9434.88 | 0 | 2381555 | 70809 | None | Vol-1 pg No.-112 10percentage | Additional for formwork, Centering & Scaffolding for Sl No 2: Earth retaining structure drainages As per Appendix-I in Volume-1 of page No.-112(@10% of Finished Rate) ---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 648.0 | 648.0 | 9.37 | False | None | None | False | None | False | 6071.76 | 0 | 2381556 | 70809 | None | Vol No-1 pg no-7I No 1.8 | Construction of Embankment by excavating the available approved Gravel Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour, rolling ,water ,all materials ,usage& all other appurtenaces required to complete the work. If the height of embankment construction is more than 1.50 m add 5 per m for every 1.50 m height or part there of ---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 474.0 | 474.0 | 247.65 | False | None | None | False | None | False | 117386.1 | 0 | 2381557 | 70809 | None | Vol No-1 pg no-16I No2.4.1 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works &
other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS
Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregates ---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 6404.0 | 6404.0 | 3.09 | False | None | None | False | None | False | 19788.36 | 0 | 2381558 | 70809 | None | Vol No-1 pg no-16 I No 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse
aggrgates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The
cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications .M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 6843.0 | 6843.0 | 35.76 | False | None | None | False | None | False | 244705.68 | 0 | 2381559 | 70809 | None | Vol-1 pg No.-111 70percentage | Additional for formwork, Centering & Scaffolding for Sl No 8: Columns & Piers As per Appendix-I in Volume-1 of page No.-111 (@70% of Finished Rate) ---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 4790.1 | 4790.1 | 5.0 | False | None | None | False | None | False | 23950.5 | 0 | 2381560 | 70809 | None | Vol-1 pg No.-111 (50percentage) | Additional for formwork, Centering & Scaffolding for Sl No 12 : plinth beam As per corrigendam 3 Appendix-I in Volume-1 of page No.-111 (@50% of Finished Rate) ---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 3421.5 | 3421.5 | 7.02 | False | None | None | False | None | False | 24018.93 | 0 | 2381561 | 70809 | None | Vol-1 pg No.-112 (60percentage ) | Additional for formwork, Centering & Scaffolding for Sl No 12 : beam & lintels As per Appendix-I in Volume-1 of page No.-112 (@60% of Finished Rate) ---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 4105.8 | 4105.8 | 8.56 | False | None | None | False | None | False | 35145.648 | 0 | 2381562 | 70809 | None | Vol-1 pg No.-112 (45percentage ) | Additional for formwork, Centering & Scaffolding for Sl No 20 : Chejjas, Canopy & Other Architectural projections of minor sections As per Appendix-I in Volume-1 of page No.-112 (@45% of Finished Rate) ---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 3079.35 | 3079.35 | 1.08 | False | None | None | False | None | False | 3325.698 | 0 | 2381563 | 70809 | None | Vol-1 pg No.-112 (50percentage ) | Additional for formwork, Centering & Scaffolding for Sl No 13 : Roof straight As per corrigendum Appendix-I in Volume-1 of page No.-112 (@ 50% of Finished Rate) ---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 3421.5 | 3421.5 | 14.1 | False | None | None | False | None | False | 48243.15 | 0 | 2381564 | 70809 | None | Vol No-1 pg no-18 I No 2.11a | Steel Fabrication Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement
including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft
annealed steel wire and other ancilary operations complete as per drawing and technical specific ation.a)Buildings ---- Work should be carried out as per the direction of engineer incharge of work. | MT | 89457.0 | 89457.0 | 4.87 | False | None | None | False | None | False | 435655.59 | 0 | 2381565 | 70809 | None | Vol No-2 pg no-14 I No 6.8 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and
sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. ---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 7969.0 | 7969.0 | 31.04 | False | None | None | False | None | False | 247357.76 | 0 | 2381566 | 70809 | None | Vol No-2 pg no-14 I No 6.15 | Providing Half brick masonry with common burnt clay Non Modularbricks of class designation 3.5 in superstructure above plinth level upto floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer
incharge of work. ---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 1033.0 | 1033.0 | 9.36 | False | None | None | False | None | False | 9668.88 | 0 | 2381567 | 70809 | None | Vol No-2 pg no-41 I No 8.2.1 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 295.0 | 295.0 | 137.26 | False | None | None | False | None | False | 40491.7 | 0 | 2381568 | 70809 | None | Vol No-2 pg no-42 I No 8.8 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished
with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 371.0 | 371.0 | 229.06 | False | None | None | False | None | False | 84981.26 | 0 | 2381569 | 70809 | None | Vol No-2 pg no-64 I No 9.34 | Flooring with 25mm thick polished tandur blue stone slabs using cementmortar 1:6, 25mm thick over existing cement concrete bed or top of roof
laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing,
polishing complete as per specifications. ---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 1545.0 | 1545.0 | 109.2 | False | None | None | False | None | False | 168714.0 | 0 | 2381570 | 70809 | None | Vol No-2 pg no-86 I No 11.34B | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat withapproved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. ---- Work should be carried out as per the direction of engineer incharge of work. | Kg | 183.0 | 183.0 | 338.94 | False | None | None | False | None | False | 62026.02 | 0 | 2381571 | 70809 | None | Vol No-2 pg no-81 I No 11.14.3.1 | Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm
thickness, including hinges, jamb, lock jamb, bead and if required angle thre shold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm,
pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer- in-charge: Profile E Fixing with adjustable lugs with split end tail to each jamb including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of theEngineer-in-Charge. ---- Work should be carried out as per the direction of engineer incharge of work. | m | 531.0 | 531.0 | 13.2 | False | None | None | False | None | False | 7009.2 | 0 | 2381572 | 70809 | None | Vol No-2 pg no-77 I No 11.5.1 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-inCharge ---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 4478.0 | 4478.0 | 5.04 | False | None | None | False | None | False | 22569.12 | 0 | 2381573 | 70809 | None | Vol No-2 pg no-79 I No 11.11.1 | Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6 PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets -grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 44mm width x 40mmheight with reinforcement of 1mm thickness and Sash with overall size of 27mm X 53mm with UPVCirections of the Engineer-in-Charge.honeycomb structure inside in lieu of GI reinforcement. Coextruded Glazing bead for fixing of glass shall be of size 9.5mm x 21.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with Crescent Locks. Wall thickness of frame & sash shall be of 2 mm .Maximum possible size 1219mm x 1219mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 5023.0 | 5023.0 | 8.64 | False | None | None | False | None | False | 43398.72 | 0 | 2381574 | 70809 | None | Vol No-2 pg no-50 I No 8.51 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 100.0 | 100.0 | 240.04 | False | None | None | False | None | False | 24004.0 | 0 | 2381575 | 70809 | None | Vol No-2 pg no-45 I No8.25 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions
of Engineer-in-charge. ---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 137.0 | 137.0 | 240.04 | False | None | None | False | None | False | 32885.48 | 0 | 2381576 | 70809 | None | Vol No-2 pg no-45 I No8.27 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give
an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface
even and sand paper smooth, cost of materials, labour complete as perspecifications and as per directions of Engineer-in-charge. ---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 53.0 | 53.0 | 229.06 | False | None | None | False | None | False | 12140.18 | 0 | 2381577 | 70809 | None | Vol No-2 pg no-45 I No8.28 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoro ughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper
smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 89.0 | 89.0 | 229.06 | False | None | None | False | None | False | 20386.34 | 0 | 2381578 | 70809 | None | Vol No-2 pg no-48 I No8.40 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops
and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per
directions of Engineer-in-charge. ---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 115.0 | 115.0 | 28.86 | False | None | None | False | None | False | 3318.9 | 0 | 2381579 | 70809 | None | Vol No-2 pg no-49 I No8.49 | Lettering with black Japan paint of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning the
surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge ---- Work should be carried out as per the direction of engineer incharge of work. | cm | 4.0 | 4.0 | 4000.0 | False | None | None | False | None | False | 16000.0 | 0 | 2381580 | 70809 | None | Vol No-2 pg no-49 I No8.43 | Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade :Two coats on new work including
preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per
directions of Engineer-in-charge ---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 94.0 | 94.0 | 17.28 | False | None | None | False | None | False | 1624.32 | 0 | 2381581 | 70809 | None | Vol No-2 pg no-125 I no -13.48 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring
conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter ---- Work should be carried out as per the direction of engineer incharge of work. | m | 291.0 | 291.0 | 21.0 | False | None | None | False | None | False | 6111.0 | 0 |
| 1706788257000 | 0 | None | None | Buildings | Construction of Two Class Rooms for Government Higher Primary School at Madaganur Village Gadag Dist/Tq (27.80 Lakhs) (ELECRIFICATION) | 49858.0 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2381582 | 70810 | None | Volume-6 PWD Part-1 (Page No.2 Item No.1.1.1) | Open Conduit System Concealed Conduit System :Supplying heavy gauge PVC conduit pipe mm dia mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary19/20mm dia 2mm thick ---- Work should be carried out as per the direction of engineer incharge of work. | Mtr | 69.0 | 69.0 | 30.0 | False | None | None | False | None | False | 2070.0 | 0 | 2381583 | 70810 | None | Volume-6 PWD Part-1 (Page No.2 Item No.1.1.2) | Concealed Conduit System :Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary25mm dia 2mm thick ---- Work should be carried out as per the direction of engineer incharge of work. | Mtr | 81.0 | 81.0 | 16.0 | False | None | None | False | None | False | 1296.0 | 0 | 2381584 | 70810 | None | Volume-6 PWD Part-1 (Page No.2 Item No.1.3.1) | Supplying heavy gauge PVC Conduit Pipe 25dia 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.19/20mm dia 2mm thick ---- Work should be carried out as per the direction of engineer incharge of work. | Mtr | 68.0 | 68.0 | 12.0 | False | None | None | False | None | False | 816.0 | 0 | 2381585 | 70810 | None | Volume-6 PWD Part-1 (Page No.2 Item No.1.3.2) | Supplying heavy gauge PVC Conduit Pipe 25dia 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.25mm dia 2mm thick ---- Work should be carried out as per the direction of engineer incharge of work. | Mtr | 79.0 | 79.0 | 12.0 | False | None | None | False | None | False | 948.0 | 0 | 2381586 | 70810 | None | Volume-6 PWD Part-1 (Page No.3Item No.1.9.2) | Supplying PVC/GI flexible conduit pipe .... mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of the pipe terminated completely25mm ---- Work should be carried out as per the direction of engineer incharge of work. | Mtr | 22.0 | 22.0 | 4.0 | False | None | None | False | None | False | 88.0 | 0 | 2381587 | 70810 | None | Volume-6 PWD Part-1 (Page No.5 Item No.2.2.1) | Supplying and wiring adopting loop system in existing PVC Conduit/casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulatedcopper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box,the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Short point upto 3Mtr from tapping point to out let via switch box ---- Work should be carried out as per the direction of engineer incharge of work. | Point | 269.0 | 269.0 | 12.0 | False | None | None | False | None | False | 3228.0 | 0 | 2381588 | 70810 | None | Volume-6 PWD Part-1 (Page No.5 Item No.2.2.2) | Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch ---- Work should be carried out as per the direction of engineer incharge of work. | Point | 379.0 | 379.0 | 2.0 | False | None | None | False | None | False | 758.0 | 0 | 2381589 | 70810 | None | Volume-6 PWD Part-1 (Page No.5 Item No.2.2.3) | Long point above 6Mtr upto 10Mtr from tapping point to out let via switch box ---- Work should be carried out as per the direction of engineer incharge of work. | Point | 555.0 | 555.0 | 2.0 | False | None | None | False | None | False | 1110.0 | 0 | 2381590 | 70810 | None | 2.3.2Volume-6 PWD Part-1 (Page No.5 I No.2.3.2) | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade,1.5 SQMM multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP. ---- Work should be carried out as per the direction of engineer incharge of work. | Mtr | 26.0 | 26.0 | 60.0 | False | None | None | False | None | False | 1560.0 | 0 | 2381591 | 70810 | None | Volume-6 PWD Part-1 (Page No.5 Item No.2.3.3) | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade,2.5 SQMM multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP. ---- Work should be carried out as per the direction of engineer incharge of work. | Mtr | 42.0 | 42.0 | 70.0 | False | None | None | False | None | False | 2940.0 | 0 | 2381592 | 70810 | None | Volume-6 PWD Part-1 (Page No.5 Item No.2.3.4) | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade,4 SQMM multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP. ---- Work should be carried out as per the direction of engineer incharge of work. | Mtr | 63.0 | 63.0 | 40.0 | False | None | None | False | None | False | 2520.0 | 0 | 2381593 | 70810 | None | Volume-6 PWD Part-1 (Page No.8 Item No.3.4.1) | Supplying and flush mounting powder coated / galvanized metal box size 1-2 way suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ---- Work should be carried out as per the direction of engineer incharge of work. | Each | 138.0 | 138.0 | 4.0 | False | None | None | False | None | False | 552.0 | 0 | 2381594 | 70810 | None | Volume-6 PWD Part-1 (Page No.8 Item No.3.4.3) | Supplying and flush mounting powder coated / galvanized metal box size 4-5way suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ---- Work should be carried out as per the direction of engineer incharge of work. | Each | 177.0 | 177.0 | 2.0 | False | None | None | False | None | False | 354.0 | 0 | 2381595 | 70810 | None | Volume-6 PWD Part-1 (Page No.8 Item No.3.4.5) | Supplying and flush mounting powder coated / galvanized metal box size 8way suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ---- Work should be carried out as per the direction of engineer incharge of work. | Each | 261.0 | 261.0 | 2.0 | False | None | None | False | None | False | 522.0 | 0 | 2381596 | 70810 | None | Volume-6 PWD Part-1 (Page No.8 Item No.3.4.6) | Supplying and flush mounting powder coated / galvanized metal box size10-12way suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ---- Work should be carried out as per the direction of engineer incharge of work. | Each | 319.0 | 319.0 | 2.0 | False | None | None | False | None | False | 638.0 | 0 | 2381597 | 70810 | None | Volume-6 PWD Part-1 (Page No.8 Item No.3.5.2) | Supplying and fixing superior quality 3Mudular modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal box. ---- Work should be carried out as per the direction of engineer incharge of work. | Each | 161.0 | 161.0 | 2.0 | False | None | None | False | None | False | 322.0 | 0 | 2381598 | 70810 | None | Volume-6 PWD Part-1 (Page No.8 Item No.3.5.3) | Supplying and fixing superior quality 4Mudular modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal box. ---- Work should be carried out as per the direction of engineer incharge of work. | Each | 175.0 | 175.0 | 2.0 | False | None | None | False | None | False | 350.0 | 0 | 2381599 | 70810 | None | Volume-6 PWD Part-1 (Page No.5 Item No.3.5.5) | Supplying and fixing superior quality 8 modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalbox. ---- Work should be carried out as per the direction of engineer incharge of work. | Each | 284.0 | 284.0 | 2.0 | False | None | None | False | None | False | 568.0 | 0 | 2381600 | 70810 | None | Volume-6 PWD Part-1 (Page No.8 Item No.3.5.6) | Supplying and fixing superior quality 10-12Mudular modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalbox. ---- Work should be carried out as per the direction of engineer incharge of work. | Each | 344.0 | 344.0 | 2.0 | False | None | None | False | None | False | 688.0 | 0 | 2381601 | 70810 | None | Volume-6 PWD Part-1 (Page No.9 Item No.3.6.1) | Supplying and fixing of 6Amps 0ne way modular switch on existing modular switch plate as per IS 3854 and IS 1293. ---- Work should be carried out as per the direction of engineer incharge of work. | Each | 102.0 | 102.0 | 18.0 | False | None | None | False | None | False | 1836.0 | 0 | 2381602 | 70810 | None | Volume-6 PWD Part-1 (Page No.9 Item No.3.6.3) | Supplying and fixing of 6Amps 3way modular Socketc on existing modular switch plate as per IS 3854 and IS 1293. ---- Work should be carried out as per the direction of engineer incharge of work. | Each | 171.0 | 171.0 | 8.0 | False | None | None | False | None | False | 1368.0 | 0 | 2381603 | 70810 | None | Volume-6 PWD Part-1 (Page No.9 Item No.3.6.4) | Supplying and fixing of modular stepped electronic fan regulator on existing modular switch plate as per and IS 1293. ---- Work should be carried out as per the direction of engineer incharge of work. | Each | 357.0 | 357.0 | 4.0 | False | None | None | False | None | False | 1428.0 | 0 | 2381604 | 70810 | None | Volume-6 PWD Part-1 (Page No.9 Item No.3.6.7) | Supplying and fixing of 16Amps 0ne way modular switch on existing modular switch plate as per IS 3854 and IS 1293. ---- Work should be carried out as per the direction of engineer incharge of work. | Each | 180.0 | 180.0 | 2.0 | False | None | None | False | None | False | 360.0 | 0 | 2381605 | 70810 | None | Volume-6 PWD Part-1 (Page No.9 Item No.3.6.9) | Supplying and fixing of32Amps modular DP Switch on existing modular switch plate as per IS 3854 and IS 1293. ---- Work should be carried out as per the direction of engineer incharge of work. | Each | 326.0 | 326.0 | 2.0 | False | None | None | False | None | False | 652.0 | 0 | 2381606 | 70810 | None | Volume-6 PWD Part-1 (Page No.9 Item No.3.6.10) | Supplying and fixing of6/16amps modular Universal Socket on existing modular switch plate as per IS 3854 and IS 1293. ---- Work should be carried out as per the direction of engineer incharge of work. | Each | 236.0 | 236.0 | 2.0 | False | None | None | False | None | False | 472.0 | 0 | 2381607 | 70810 | None | Volume-6 PWD Part-1 (Page No.10 Item No.3.14.6) | Supplying and fixing of 6Amps pendent holder on existing board. ---- Work should be carried out as per the direction of engineer incharge of work. | Each | 71.0 | 71.0 | 4.0 | False | None | None | False | None | False | 284.0 | 0 | 2381608 | 70810 | None | Volume-6 PWD Part-1 (Page No.14 Item No.5.7.3) | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers.63amps ---- Work should be carried out as per the direction of engineer incharge of work. | Each | 401.0 | 401.0 | 2.0 | False | None | None | False | None | False | 802.0 | 0 | 2381609 | 70810 | None | Volume-6 PWD Part-1 (Page No.30 Item No.6.3.1) | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm) Economy model ---- Work should be carried out as per the direction of engineer incharge of work. | Each | 2984.0 | 2984.0 | 4.0 | False | None | None | False | None | False | 11936.0 | 0 | 2381610 | 70810 | None | Volume-6 PWD Part-1 (Page No.43 I No.11.3.2) | LED Indoor Supplying of 1x4' feet - LED PVC Square Batten 20/22W with high quality diffuser with Life of 25000 burning hours & 70 lumen maintenance with CRI 80. Power Input: 220-240V @ 50Hz & Power factor 0.9 along with CE approved drivers. 2 years Warranty against any manufacturing defect working under standard electrical condition ---- Work should be carried out as per the direction of engineer incharge of work. | Each | 690.0 | 690.0 | 4.0 | False | None | None | False | None | False | 2760.0 | 0 | 2381611 | 70810 | None | Volume-6 PWD Part-1 (Page No.47 Item No.11.11.4) | Supplying & fixing of retrofit type LED bulb .W with OPAL acrylicdiffuser comprising of LED source with CCT 6500 degree K, CRI 70
efficacy 80 lumen per W, life25000 burning hours and Compliance to IS 10322IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic
driver integrated in the system, with PF 0.95, power loss should 5% oflamp Wage., short circuit & open circuit protection to be integrated incircuit, THD less than 20, Life as per LM 79. The operating input voltage
should be between 130 to 275 V. BIS Approved and Tested byNABLCPRI accredited laboratory with 2 years Warranty against any
manufacturing defect working under standard electrical condition. ---- Work should be carried out as per the direction of engineer incharge of work. | Each | 154.0 | 154.0 | 4.0 | False | None | None | False | None | False | 616.0 | 0 | 2381612 | 70810 | None | Volume-6 PWD Part-1 (Page No.56 Item No.13.7.1) | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. ---- Work should be carried out as per the direction of engineer incharge of work. | Each | 122.0 | 122.0 | 8.0 | False | None | None | False | None | False | 976.0 | 0 | 2381613 | 70810 | None | Volume-6 PWD Part-1 (Page No.57 Item No.13.10) | Fixing a ceiling / Wall mounting fan of all capacities and all types to
the existing 'S'' hook with fan regulator to the existing board together
with supplying and fixing 5 A. ceiling rose, necessary length of
23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. ---- Work should be carried out as per the direction of engineer incharge of work. | Each | 171.0 | 171.0 | 4.0 | False | None | None | False | None | False | 684.0 | 0 | 2381614 | 70810 | None | ESCOM SR 2023-24 Item No.51.01 Page No.22) | Grounding Material
GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long,
3.2 mm thick with bolt, nut, GI Strips and washer
complete Minimum Weight of GI Pipe: 7.3 Kg (ESCOM SR 2023-24 Item No.51.01 Page No.22) ---- Work should be carried out as per the direction of engineer incharge of work. | Each | 743.0 | 743.0 | 2.0 | False | None | None | False | None | False | 1486.0 | 0 | 2381615 | 70810 | None | ESCOM SR 2023-24 Item No.51.02 Page No.22) | Grounding Material
Good Quality well burnt Charcoal for grounding
purposes packed in non returnable gunny bag of 30 Kg
each (BESCOM Part-III 11 KV Materials Item No.54.02 Page No.17) ---- Work should be carried out as per the direction of engineer incharge of work. | Each | 676.0 | 676.0 | 2.0 | False | None | None | False | None | False | 1352.0 | 0 | 2381616 | 70810 | None | ESCOM SR 2023-24 I No.1.6.1 ordinary soil P No.43 | Digging of Pit for providing GI Pipe type Earthing Ordinary Soil (ESCOM SR 2023-24 Item No.1.6.1 ordinary soil Page No.43) ---- Work should be carried out as per the direction of engineer incharge of work. | Per Pit | 759.0 | 759.0 | 2.0 | False | None | None | False | None | False | 1518.0 | 0 |
|
|
---|