createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1706852669219
version4
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee770.00
emd90000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose19-02-2024 17:30:00
tenderQueryClose17-02-2024 17:30:00
technicalBidOpen21-02-2024 11:00:00
publishedDate02-02-2024 17:54:39
publishedByPostDUDC_PD_KLB
publishedByUserKPE16973 - MUNAWAR DOWLA
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonRamchandra Katke
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber9740339572
tenderSupplierListNone
tenderSchedule
createdTs1706852669240
version6
createdDateNone
modifiedDateNone
tenderNumberDMA/2023-24/BD/WORK_INDENT12361
titlePACKAGE1 1) Construction of Aganwadi Building at Ward no 2 in KAMALAPUR TP 2)Construction of Aganwadi Building at Ward no 5 in KAMALAPUR TP
descriptionPACKAGE1 1) Construction of Aganwadi Building at Ward no 2 in KAMALAPUR TP 2)Construction of Aganwadi Building at Ward no 5 in KAMALAPUR TP
categoryWORKS
categoryTextWorks
ecv3050236.02
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2188
locationNameDMA District Urban Development Cell Kalaburagi
provisionalAmount3600000.0
groupOverheadTotalNone
fileNumberNo/DUDC/KKRDB/2022-23/TPK/1
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17068526690000NoneNoneBuildingsPACKAGE1 1) Construction of Aganwadi Building at ard no 2 in KAMALAPUR TP1525118.01
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
239584071334Nonecode01Earth work in surface excavation by mechanical means for lowering and leveling the ground for all works other than foundation in all kinds of soils and upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery and other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth (PWD CSR VOL I for the year 2021-22. I. No. 1.12 P.No. 08 )Cum68.2568.2515.0FalseNoneNoneFalseNoneFalse1023.750
239584171334Nonecode02Earth work excavation for Foundation by mechanical means for all works and depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery and other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m. (PWD CSR VOL I for the year 2021-22. I. No. 1.14.1 P.No. 08 )Cum76.6576.6543.08FalseNoneNoneFalseNoneFalse3302.0820
239584271334Nonecode03Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement and formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates (PWD CSR VOL I for the year 2021-22. I. No. 2.1.3 P.No. 15)Cum5831.75831.71.58FalseNoneNoneFalseNoneFalse9214.0860
239584371334Nonecode04Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works and other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead and lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement and formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(PWD CSR VOL I for the year 2021-22. I. No. 2.4.2 P.No. 17)Cum6454.396454.396.34FalseNoneNoneFalseNoneFalse40920.83260
239584471334Nonecode05Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works and other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead and lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement and formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(PWD CSR VOL I for the year 2021-22. I. No. 2.4.2 P.No. 17)Cum10652.8810652.880.91FalseNoneNoneFalseNoneFalse9694.12080
239584571334Nonecode06Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement and formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates (PWD CSR VOL I for the year 2021-22. I. No. 2.1.3 P.No. 15)Cum5831.745831.741.59FalseNoneNoneFalseNoneFalse9272.46660
239584671334Nonecode07Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) (PWD SR for Buildings VOL II for the year 2021-22. I. No. 5.1.1 P.No. 09)Cum4987.54987.57.15FalseNoneNoneFalseNoneFalse35660.6250
239584771334Nonecode08Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement and formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates (PWD CSR VOL I for the year 2021-22. I. No. 2.1.4 P.No. 15)Cum6014.46014.41.19FalseNoneNoneFalseNoneFalse7157.1360
239584871334Nonecode09Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement and formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates (PWD CSR VOL I for the year 2021-22. I. No. 2.1.3 P.No. 15)Cum5831.75831.70.33FalseNoneNoneFalseNoneFalse1924.4610
239584971334Nonecode10Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery and other incidental charges complete as per the direction of engineer incharge of work. (PWD SR for Buildings VOL II for the year 2021-22. I. No. 6.2 P.No. 13)Cum7030.87030.85.55FalseNoneNoneFalseNoneFalse39020.940
239585071334Nonecode11Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement and formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates (PWD CSR VOL I for the year 2021-22. I. No. 2.1.4 P.No. 15)Cum6014.46014.40.61FalseNoneNoneFalseNoneFalse3668.7840
239585171334Nonecode12Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usageand all other appurtenaces required to complete the work. (PWD SR for Buildings VOL I for the year 2021-22. I. No. 1.8 P.No. 7)Cum401.0401.076.34FalseNoneNoneFalseNoneFalse30612.340
239585271334Nonecode13Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement and formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates (PWD CSR VOL I for the year 2021-22. I. No. 2.1.3 P.No. 15)Cum5831.75831.76.53FalseNoneNoneFalseNoneFalse38081.0010
239585371334Nonecode14Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works and other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead and lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement and formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(PWD CSR VOL I for the year 2021-22. I. No. 2.4.2 P.No. 17)Cum9399.69399.64.59FalseNoneNoneFalseNoneFalse43144.1640
239585471334Nonecode15Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD CSR VOL I for the year 2021-22. I. No. 2.5.1 P.No. 17)Cum11034.8711034.871.6FalseNoneNoneFalseNoneFalse17655.7920
239585571334Nonecode16Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery and other incidental charges complete as per the direction of engineer incharge of work. (PWD SR for Buildings VOL II for the year 2021-22. I. No. 6.8 P.No. 14)Cum7024.57024.526.84FalseNoneNoneFalseNoneFalse188537.580
239585671334Nonecode17Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery and other incidental charges complete as per the direction of engineer incharge of work. (PWD SR for Buildings VOL II for the year 2021-22. I. No. 6.15 P.No. 14)Sqm909.3909.318.38FalseNoneNoneFalseNoneFalse16712.9340
239585771334Nonecode18Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD CSR VOL I for the year 2021-22. I. No. 2.5.1 P.No. 17)Cum10385.7610385.761.92FalseNoneNoneFalseNoneFalse19940.65920
239585871334Nonecode19Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD CSR VOL I for the year 2021-22. I. No. 2.5.1 P.No. 17)Cum9412.19412.10.46FalseNoneNoneFalseNoneFalse4329.5660
239585971334Nonecode20Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD CSR VOL I for the year 2021-22. I. No. 2.5.1 P.No. 17)Cum11034.8711034.870.42FalseNoneNoneFalseNoneFalse4634.64540
239586071334Nonecode21Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD CSR VOL I for the year 2021-22. I. No. 2.5.1 P.No. 17)Cum10385.7610385.764.25FalseNoneNoneFalseNoneFalse44139.480
239586171334Nonecode22Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD CSR VOL I for the year 2021-22. I. No. 2.5.1 P.No. 17)Cum9736.659736.6510.06FalseNoneNoneFalseNoneFalse97950.6990
239586271334Nonecode23Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery and other incidental charges complete as per the direction of engineer incharge of work. (PWD SR for Buildings VOL II for the year 2021-22. I. No. 6.15 P.No. 14)Sqm909.3909.322.99FalseNoneNoneFalseNoneFalse20904.8070
239586371334Nonecode24Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2021-22. I. No. 8.1.2 P.No. 41)Sqm207.9207.963.82FalseNoneNoneFalseNoneFalse13268.1780
239586471334Nonecode25Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(PWD SR for Buildings VOL II for the year 2021-22. I. No. 8.1.1 P.No. 41)Sqm223.65223.65194.91FalseNoneNoneFalseNoneFalse43591.62150
239586571334Nonecode26Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2021-22. I. No. 8.8 P.No. 42)Sqm322.35322.35203.94FalseNoneNoneFalseNoneFalse65740.0590
239586671334Nonecode27Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2021-22. I. No. 8.5.2 P.No. 42)Sqm308.7308.731.64FalseNoneNoneFalseNoneFalse9767.2680
239586771334Nonecode28Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (PWD SR for Buildings VOL II for the year 2021-22. I. No. 8.51 P.No. 50)Sqm87.1587.1572.84FalseNoneNoneFalseNoneFalse6348.0060
239586871334Nonecode29Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. (PWD SR for Buildings VOL II for the year 2021-22. I. No. 12.13.2 P.No. 100)Cum64683.1564683.150.39FalseNoneNoneFalseNoneFalse25226.42850
239586971334Nonecode30Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per specification. 35 mm thick both side commercial (PWD SR for Buildings VOL II for the year 2021-22. I. No. 12.57.6 P.No. 106)Sqm3091.23091.29.45FalseNoneNoneFalseNoneFalse29211.840
239587071334Nonecode31Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. (PWD SR for Buildings VOL II for the year 2021-22. I. No. 12.60 P.No. 107)Nos873.6873.65.0FalseNoneNoneFalseNoneFalse4368.00
239587171334Nonecode32Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. (PWD SR for Buildings VOL II for the year 2021-22. I. No. 12.58 P.No. 107)Nos114.45114.455.0FalseNoneNoneFalseNoneFalse572.250
239587271334Nonecode33Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete (PWD SR for Buildings VOL II for the year 2021-22. I. No. 12.62 P.No. 107)Nos183.75183.755.0FalseNoneNoneFalseNoneFalse918.750
239587371334Nonecode34Providing and fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top and bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet and 30x50mm wide to form stiles and 5mm thick and 75mm wide Prelaminated PVC Sheets for top rail, lock rail and bottom rail on either side and 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail and bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles and rails with PVC Designer beading on either side and joined together with solvent cement adhesive etc., Complete as per manufacturers specification and direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. with one side prelam (PWD SR for Buildings VOL II for the year 2021-22. I. No. 12.55.2 P.No. 106)Sqm2998.82998.83.0FalseNoneNoneFalseNoneFalse8996.40
239587471334Nonecode35Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. (PWD SR for Buildings VOL II for the year 2021-22. I. No. 11.34B P.No. 85)Kg164.85164.85111.51FalseNoneNoneFalseNoneFalse18382.42350
239587571334Nonecode36Providing and fixing of 2track x 2panel sliding windows made out of multi chambered UPVC(Matching to RAL9016) sections and with minimum TiO2(Titanium Dioxide) at 6 PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets grey color having isolated drainage and reinforced with Galvanized Iron profile throughout the window frame. The outer frame having an overall size of 44mm width x 40mmheight with reinforcement of 1mm thickness and Sash with overall size of 27mm X 53mm with UPVC honeycomb structure inside in lieu of GI reinforcement. Coextruded Glazing bead for fixing of glass shall be of size 9.5mm x 21.5mm. Windows shall be provided with 5mm plain float glass, standard hardware and single point locking system with Crescent Locks. Wall thickness of frame and sash shall be of 2 mm.Maximum possible size 1219mm x 1219mm. (The cost is inclusive of all fixtures and separate charges for minor TandP's shall not be made) (PWD SR for Buildings VOL II for the year 2021-22. I. No. 12.84 P.No. 110)Sqm4319.74319.73.96FalseNoneNoneFalseNoneFalse17106.0120
239587671334Nonecode37Providing and fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor TandPs shall not be made) (PWD SR for Buildings VOL II for the year 2021-22. I. No. 12.85 P.No. 110)Sqm5113.55113.51.35FalseNoneNoneFalseNoneFalse6903.2250
239587771334Nonecode38Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours and shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement and matching pigments etc. complete. Size of Tile 600x600 mm (PWD SR for Buildings VOL II for the year 2021-22. I. No. 9.17.2 P.No. 61)Sqm1157.11157.145.62FalseNoneNoneFalseNoneFalse52786.9020
239587871334Nonecode39Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. (CSR for Buildings VOL II for the year 2021-22. I. No. 9.9 P.No. 60)Sqm635.25635.2510.5FalseNoneNoneFalseNoneFalse6670.1250
239587971334Nonecode40Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. (PWD SR for Buildings VOL II for the year 2021-22. I. No. 9.11 P.No. 60)Sqm800.1800.120.16FalseNoneNoneFalseNoneFalse16130.0160
239588071334Nonecode41Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. (PWD SR for Buildings VOL II for the year 2021-22. I. No. 9.39 P.No. 65)Sqm1088.851088.8532.72FalseNoneNoneFalseNoneFalse35627.1720
239588171334Nonecode42Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m over an under coat of primer applied @ 0.80 ltr/10 m of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2021-22. I. No. 8.33.3 P.No. 47)Sqm111.3111.35.31FalseNoneNoneFalseNoneFalse591.0030
239588271334Nonecode43Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m over and including one coat of Special primer applied @ 0.75 ltr /10 m with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2021-22. I. No. 8.33.1 P.No. 46)Sqm123.9123.9194.91FalseNoneNoneFalseNoneFalse24149.3490
239588371334Nonecode44Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m over and including one coat of Special primer applied @ 0.75 ltr /10 m with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2021-22. I. No. 8.33.1 P.No. 46)Sqm123.9123.963.82FalseNoneNoneFalseNoneFalse7907.2980
239588471334Nonecode45Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m over and including riming coat of exterior primer applied @ 2.20 kg/10 m) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2021-22. I. No. 8.30 P.No. 46)Sqm142.8142.8203.94FalseNoneNoneFalseNoneFalse29122.6320
239588571334Nonecode46Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(CSR, 2021-22, VOL-II,Item No. 11.2, Pg. No. 75 As per 4th Quarter Issue Rate).Kg106.05106.05189.55FalseNoneNoneFalseNoneFalse20101.77750
239588671334Nonecode47Providing and fixing UV stabilised fiberglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated 'J' or 'L' hooks, bolts and nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. 2 mm thick Flat (PWD SR for Buildings VOL II for the year 2021-22. I. No. 7.33.2 P.No. 26)Sqm927.15927.1521.0FalseNoneNoneFalseNoneFalse19470.150
239588771334Nonecode48Providing Thermo-Mechanically Treated bars of grade Fe-550 or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) (CSR for Buildings VOL II for the year 2021-22. I. No. 11.32 P.No. 84)Kg96.696.63006.16FalseNoneNoneFalseNoneFalse290395.0560
239588871334Nonecode49Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of the slab = 0.50 m2 CSR for the year 2021-22. No.10.1.1 P.No.68Sqm3624.63624.61.2FalseNoneNoneFalseNoneFalse4349.520
239588971334Nonecode50Providing and fixing kitchen sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P. brass waste complete, including painting the fittings and brackets, cutting and making good the walls wherever required: White glazed fire clay kitchen sink of size 600x450x 250 mm CSR for the year 2021-22. No.14.9.1 P.No.125Each2640.752640.751.0FalseNoneNoneFalseNoneFalse2640.750
239589071334Nonecode51Providing and laying heavy duty cobble stones 60mm thick interlock pavers, using cement and course sand for manufacture of blocks of approved size, shape and colour with a minimum compressive strength of 281 kg per m2 over 50mm thick sand bed ( average thickness ) and compacting with plate vibrator having 3 tons compaction force thereby forcing part of sand underneath to come up in between joints, final compaction of paver surface joints into its final level , including cost of materials, labour and Usage charges of machinery complete as per specifications. (CSR for Buildings VOL II for the year 2021-22. I. No. 9.31 P.No.64)Kg1141.351141.3518.0FalseNoneNoneFalseNoneFalse20544.30
239589171334Nonecode52Supplying heavy gauge PVC conduit pipe 19/20 mm dia 2 mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. (PWD - Part I - Electrical Works SR for the year 2022-23. I. No. 1.1.1 P.No. 01 of 47 )m68.068.040.0FalseNoneNoneFalseNoneFalse2720.00
239589271334Nonecode53Providing and placing on terrace (on all floor levels), polyethylene water storage tanks IS: 12701 marked, with cover and suitable locking arrangements and making necessary holes for inlet, outlet and over flow pipes but without fittings and the base support for tank (PWD SR for Buildings VOL II for the year 2021-22. I. No. 13.34 1st Addenda w.e.f 21.04.2022)Ltr8.48.4500.0FalseNoneNoneFalseNoneFalse4200.00
239589371334Nonecode54Supplying PVC ring tight pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and (WS and UGD Works CSR for the year 2021-22. No. 1.7 SOR CODE : M010G P.No.134)m413.7413.75.0FalseNoneNoneFalseNoneFalse2068.50
239589471334Nonecode5540MM Dia Pipe over terrace distribution from Tankm492.45492.455.0FalseNoneNoneFalseNoneFalse2462.250
239589571334Nonecode5625mm dia Pipe in W/Cm499.8499.820.0FalseNoneNoneFalseNoneFalse9996.00
239589671334Nonecode5720mm dia Pipe in W/Cm391.65391.653.0FalseNoneNoneFalseNoneFalse1174.950
239589771334Nonecode58Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15mm C.P. brass pillar tap (PWD SR for Buildings VOL II for the year 2021-22. I. No. 14.7.2 Page No. 124)Each2263.82263.81.0FalseNoneNoneFalseNoneFalse2263.80
239589871334Nonecode59Providing and fixing brass bib cock of approved quality : 15 mm nominal bore (PWD SR for Buildings VOL II for the year 2021-22. I. No. 13.2.1 Page No. 115)Nos342.3342.33.0FalseNoneNoneFalseNoneFalse1026.90
239589971334Nonecode60Providing and fixing white vitreous china water closet squatting pan (Indian type) : 14.13.1 Long pattern W.C. pan of size 580 mm (PWD SR for Buildings VOL II for the year 2021-22. I. No. 14.13.1 P.No. 126)Each1210.651210.652.0FalseNoneNoneFalseNoneFalse2421.30
239590071334Nonecode61Constructing brick masonry chamber of internal dimension 600x600 mm and depth of 600 mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150 mm thick with 1:3:6, lastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75 mm thick for fixing CI cover and frame etc. excluding the cost of CI frame and cover. WS and UGD Works CSR for the year 2021-22. No. 9 SOR CODE: T130B P.No.187No5225.855225.851.0FalseNoneNoneFalseNoneFalse5225.850
239590171334Nonecode62Concealed Conduit System Supplying heavy gauge PVC conduit pipe ……mm dia .......mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary (Elec SR -2022-23) P.No.2, I.No.1.2 (1.2.2) (25mm dia 2mm thick)Mtr70.070.015.0FalseNoneNoneFalseNoneFalse1050.00
239590271334Nonecode63Supplying heavy gauge PVC Conduit Pipe ….dia .......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. (Elec SR -2022-23) P.No.2, I.No.1.3 (1.3.2) (25mm dia 2mm thick)(Groove)Mtr80.080.015.0FalseNoneNoneFalseNoneFalse1200.00
239590371334Nonecode64Supplying and fixing PVC/metal conduit Deep junction box (Elec SR -2022-23)P.No.2 and 3, I.No.1.5(1.5.2) (25mm dia 2mm thick)Mtr51.051.08.0FalseNoneNoneFalseNoneFalse408.00
239590471334Nonecode65Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, Finishing with necessary cement plastering complete. (Elec SR -2022-23)P.No.3, I.No.1.6 (1,6.3) (10"x7"x3")Each101.0101.02.0FalseNoneNoneFalseNoneFalse202.00
239590571334Nonecode66Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, Finishing with necessary cement plastering complete. (Elec SR -2022-23)P.No.3, I.No.1.6 (1,6.4) (8"x6"x3")Each75.075.02.0FalseNoneNoneFalseNoneFalse150.00
239590671334Nonecode67Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, Finishing with necessary cement plastering complete. (Elec SR -2022-23)P.No.3, I.No.1.6 (1,6.5) (4"x4"x3")Each69.069.02.0FalseNoneNoneFalseNoneFalse138.00
239590771334Nonecode68Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, Finishing with necessary cement plastering complete. (Elec SR -2022-23)P.No.3, I.No.1.6.2 (Fan Box)No105.0105.03.0FalseNoneNoneFalseNoneFalse315.00
239590871334Nonecode69Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP A (Elec SR -2022-23)P.No.5, I.No.2.1 (2.1.1) (Point Wiring)Point276.0276.03.0FalseNoneNoneFalseNoneFalse828.00
239590971334Nonecode70Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP A. Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch (Elec SR -2022-23)P.No.5, I.No.2.1 (2.1.2) (Point Wiring)Point386.0386.03.0FalseNoneNoneFalseNoneFalse1158.00
239591071334Nonecode71Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP A. Long point above 6Mtr upto 10Mtr from tapping point to out let via switch(Elec SR -2022-23)P.No.5, I.No.2.1 (2.1.3) (Point Wiring)Point567.0567.06.0FalseNoneNoneFalseNoneFalse3402.00
239591171334Nonecode72Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 and confirming to GTP of GROUP -A. (Elec SR -2022-23)P.No.6, I.No.2.5 (2.5.2) (1.5 Sq.mm)Mtr69.069.012.0FalseNoneNoneFalseNoneFalse828.00
239591271334Nonecode73Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 and confirming to GTP of GROUP -A.(Elec SR -2022-23)P.No.6, I.No.2.5 (2.5.3) (2.5 Sq.mm)Mtr88.088.012.0FalseNoneNoneFalseNoneFalse1056.00
239591371334Nonecode74Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 and confirming to GTP of GROUP -A. (Elec SR -2022-23)P.No.6, I.No.2.5 (2.5.4) (4 Sq.mm)Mtr112.0112.012.0FalseNoneNoneFalseNoneFalse1344.00
239591471334Nonecode75Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 and confirming to GTP of GROUP -A. (Elec SR -2022-23)P.No.6, I.No.2.5 (2.5.5) (6 Sq.mm)Mtr158.0158.012.0FalseNoneNoneFalseNoneFalse1896.00
239591571334Nonecode76Supplying 6A flush type socket and 6 amps flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 ((Elec SR -2022-23)P.No.15, I.No.3.1 (3.1.2) (6A 'U' Socket)Each143.0143.03.0FalseNoneNoneFalseNoneFalse429.00
239591671334Nonecode77Supplying and fixing/replacing of 6/16/32Amps electrical accessories on existing switch board. GROUP A (Elec SR -2022-23)P.No.18, I.No.3.15 (3.1.1) (6A Switches)Each121.0121.03.0FalseNoneNoneFalseNoneFalse363.00
239591771334Nonecode78Supplying and mounting 2 Nos. of 2 way 6 amps flush type switches either surface/flush mounted on existing gang box or in 4mm thick plastic sheet and mounted on a flush mounted wooden box and wiring as per IS 1293 (Elec SR -2022-23) P.No.15, I.No.3.2 (2Way Switches)Each162.0162.01.0FalseNoneNoneFalseNoneFalse162.00
239591871334Nonecode79Supply and fixing of Bakelite D.P/Socket/ switch with/without neon indicator over existing wood board or flush mounting in plastic plates/nitches as per IS 1293 and IS 3854 GROUP A(Elec SR -2022-23)P.No.15, I.No.3.3 (3.3..1) (32 A Flush type DP's)Each91.091.01.0FalseNoneNoneFalseNoneFalse91.00
239591971334Nonecode80Supply and fixing of Bakelite D.P/Socket/ switch with/without neon indicator over existing wood board or flush mounting in plastic plates/nitches as per IS 1293 and IS 3854 GROUP A (Elec SR -2022-23) P.No.15, I.No.3.3 (3.3.3) (16A 'U' Socket)Each149.0149.01.0FalseNoneNoneFalseNoneFalse149.00
239592071334Nonecode81Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm) (Elec SR -2022-23) P.No.78, I.No.6.3 (6.3.1) (Ceiling Fan)Each2085.02085.01.0FalseNoneNoneFalseNoneFalse2085.00
239592171334Nonecode82Supplying and fixing regular MCB distribution boards onwall/ood board / flush mounting using required clA, bolts,nuts etc., with provision for fixing suitable type capacityMCB's single phase/3 phase/single door with powder coatedpainting Made out of 14 SWG MS enclosure.(Elec SR -2022-23) P.No.47, I.No.5.18.12 6 Way TP and NEach3735.03735.01.0FalseNoneNoneFalseNoneFalse3735.00
239592271334Nonecode83Supplying and fixing of retrofit type - LED bulb ...... W withOPAL acrylic diffuser comprising of LED source with CCT 6500degree K, CRImore than 70%. efficacy more than80 lumen per W, lifemore than 25000burning hours and Compliance to IS 10322/IEC 60598, LM 79and LM 80. The LED are driven by HF electronic driver integratedin the system, with PF more than 0.95, power loss should less than 5% of lampWage., short circuit and open circuit protection to be integratedin the circuit, THD less than 20%, Life as per LM 79. Theoperating input voltage should be between 130 to 275 V. BISApproved and Tested by NABL/CPRI accredited laboratorywith 2 years Warranty against any manufacturing defect working under standard electrical condition.(Elec SR -2022-23) P.No.38 ITEM NO. 11.11.7( 18W Bulb)No.436.0436.05.0FalseNoneNoneFalseNoneFalse2180.00
17068526690000NoneNoneBuildingsPACKAGE 1 2)Construction of Aganwadi Building at Ward no 5 in KAMALAPUR TP1525118.01
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
239592371335Nonecode01Earth work in surface excavation by mechanical means for lowering and leveling the ground for all works other than foundation in all kinds of soils and upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery and other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth (PWD CSR VOL I for the year 202122. I. No 1.12 P.No 08 )Cum68.2568.2515.0FalseNoneNoneFalseNoneFalse1023.750
239592471335Nonecode02Earth work excavation for Foundation by mechanical means for all works and depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery and other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m. (PWD CSR VOL I for the year 202122. I. No 1.14.1 P.No 08 )Cum76.6576.6543.08FalseNoneNoneFalseNoneFalse3302.0820
239592571335Nonecode03Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement and formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates (PWD CSR VOL I for the year 202122. I. No 2.1.3 P.No 15)Cum5831.75831.71.58FalseNoneNoneFalseNoneFalse9214.0860
239592671335Nonecode04Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works and other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead and lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement and formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(PWD CSR VOL I for the year 202122. I. No 2.4.2 P.No 17)Cum6454.396454.396.34FalseNoneNoneFalseNoneFalse40920.83260
239592771335Nonecode05Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works and other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead and lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement and formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(PWD CSR VOL I for the year 202122. I. No 2.4.2 P.No 17)Cum10652.8810652.880.91FalseNoneNoneFalseNoneFalse9694.12080
239592871335Nonecode06Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement and formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates (PWD CSR VOL I for the year 202122. I. No 2.1.3 P.No 15)Cum5831.745831.741.59FalseNoneNoneFalseNoneFalse9272.46660
239592971335Nonecode07Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) (PWD SR for Buildings VOL II for the year 202122. I. No 5.1.1 P.No 09)Cum4987.54987.57.15FalseNoneNoneFalseNoneFalse35660.6250
239593071335Nonecode08Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement and formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates (PWD CSR VOL I for the year 202122. I. No 2.1.4 P.No 15)Cum6014.46014.41.19FalseNoneNoneFalseNoneFalse7157.1360
239593171335Nonecode09Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement and formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates (PWD CSR VOL I for the year 202122. I. No 2.1.3 P.No 15)Cum5831.75831.70.33FalseNoneNoneFalseNoneFalse1924.4610
239593271335Nonecode10Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery and other incidental charges complete as per the direction of engineer incharge of work. (PWD SR for Buildings VOL II for the year 202122. I. No 6.2 P.No 13)Cum7030.87030.85.55FalseNoneNoneFalseNoneFalse39020.940
239593371335Nonecode11Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement and formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates (PWD CSR VOL I for the year 202122. I. No 2.1.4 P.No 15)Cum6014.46014.40.61FalseNoneNoneFalseNoneFalse3668.7840
239593471335Nonecode12Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usageand all other appurtenaces required to complete the work. (PWD SR for Buildings VOL I for the year 202122. I. No 1.8 P.No 7)Cum401.0401.076.34FalseNoneNoneFalseNoneFalse30612.340
239593571335Nonecode13Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement and formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates (PWD CSR VOL I for the year 202122. I. No 2.1.3 P.No 15)Cum5831.75831.76.53FalseNoneNoneFalseNoneFalse38081.0010
239593671335Nonecode14Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works and other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead and lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement and formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(PWD CSR VOL I for the year 202122. I. No 2.4.2 P.No 17)Cum9399.69399.64.59FalseNoneNoneFalseNoneFalse43144.1640
239593771335Nonecode15Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD CSR VOL I for the year 202122. I. No 2.5.1 P.No 17)Cum11034.8711034.871.6FalseNoneNoneFalseNoneFalse17655.7920
239593871335Nonecode16Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery and other incidental charges complete as per the direction of engineer incharge of work. (PWD SR for Buildings VOL II for the year 202122. I. No 6.8 P.No 14)Cum7024.57024.526.84FalseNoneNoneFalseNoneFalse188537.580
239593971335Nonecode17Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery and other incidental charges complete as per the direction of engineer incharge of work. (PWD SR for Buildings VOL II for the year 202122. I. No 6.15 P.No 14)Sqm909.3909.318.38FalseNoneNoneFalseNoneFalse16712.9340
239594071335Nonecode18Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD CSR VOL I for the year 202122. I. No 2.5.1 P.No 17)Cum10385.7610385.761.92FalseNoneNoneFalseNoneFalse19940.65920
239594171335Nonecode19Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD CSR VOL I for the year 202122. I. No 2.5.1 P.No 17)Cum9412.19412.10.46FalseNoneNoneFalseNoneFalse4329.5660
239594271335Nonecode20Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD CSR VOL I for the year 202122. I. No 2.5.1 P.No 17)Cum11034.8711034.870.42FalseNoneNoneFalseNoneFalse4634.64540
239594371335Nonecode21Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD CSR VOL I for the year 202122. I. No 2.5.1 P.No 17)Cum10385.7610385.764.25FalseNoneNoneFalseNoneFalse44139.480
239594471335Nonecode22Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD CSR VOL I for the year 202122. I. No 2.5.1 P.No 17)Cum9736.659736.6510.06FalseNoneNoneFalseNoneFalse97950.6990
239594571335Nonecode23Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery and other incidental charges complete as per the direction of engineer incharge of work. (PWD SR for Buildings VOL II for the year 202122. I. No 6.15 P.No 14)Sqm909.3909.322.99FalseNoneNoneFalseNoneFalse20904.8070
239594671335Nonecode24Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. (PWD SR for Buildings VOL II for the year 202122. I. No 8.1.2 P.No 41)Sqm207.9207.963.82FalseNoneNoneFalseNoneFalse13268.1780
239594771335Nonecode25Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge.(PWD SR for Buildings VOL II for the year 202122. I. No 8.1.1 P.No 41)Sqm223.65223.65194.91FalseNoneNoneFalseNoneFalse43591.62150
239594871335Nonecode26Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. (PWD SR for Buildings VOL II for the year 202122. I. No 8.8 P.No 42)Sqm322.35322.35203.94FalseNoneNoneFalseNoneFalse65740.0590
239594971335Nonecode27Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. (PWD SR for Buildings VOL II for the year 202122. I. No 8.5.2 P.No 42)Sqm308.7308.731.64FalseNoneNoneFalseNoneFalse9767.2680
239595071335Nonecode28Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (PWD SR for Buildings VOL II for the year 202122. I. No 8.51 P.No 50)Sqm87.1587.1572.84FalseNoneNoneFalseNoneFalse6348.0060
239595171335Nonecode29Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. (PWD SR for Buildings VOL II for the year 202122. I. No 12.13.2 P.No 100)Cum64683.1564683.150.39FalseNoneNoneFalseNoneFalse25226.42850
239595271335Nonecode30Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (partI) 1991. from manufacturer complete as per specification. 35 mm thick both side commercial (PWD SR for Buildings VOL II for the year 202122. I. No 12.57.6 P.No 106)Sqm3091.23091.29.45FalseNoneNoneFalseNoneFalse29211.840
239595371335Nonecode31Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. (PWD SR for Buildings VOL II for the year 202122. I. No 12.60 P.No 107)No873.6873.65.0FalseNoneNoneFalseNoneFalse4368.00
239595471335Nonecode32Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. (PWD SR for Buildings VOL II for the year 202122. I. No 12.58 P.No 107)No114.45114.455.0FalseNoneNoneFalseNoneFalse572.250
239595571335Nonecode33Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete (PWD SR for Buildings VOL II for the year 202122. I. No 12.62 P.No 107)No183.75183.755.0FalseNoneNoneFalseNoneFalse918.750
239595671335Nonecode34Providing and fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top and bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet and 30x50mm wide to form stiles and 5mm thick and 75mm wide Prelaminated PVC Sheets for top rail, lock rail and bottom rail on either side and 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail and bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles and rails with PVC Designer beading on either side and joined together with solvent cement adhesive etc., Complete as per manufacturers specification and direction of Engineerincharge fixed to frames with 3 No of 75mm Aluminium hinges. with one side prelam (PWD SR for Buildings VOL II for the year 202122. I. No 12.55.2 P.No 106)Sqm2998.82998.83.0FalseNoneNoneFalseNoneFalse8996.40
239595771335Nonecode35Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. (PWD SR for Buildings VOL II for the year 202122. I. No 11.34B P.No 85)Kg164.85164.85111.51FalseNoneNoneFalseNoneFalse18382.42350
239595871335Nonecode36Providing and fixing of 2track x 2panel sliding windows made out of multi chambered UPVC(Matching to RAL9016) sections and with minimum TiO2(Titanium Dioxide) at 6 PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets grey color having isolated drainage and reinforced with Galvanized Iron profile throughout the window frame. The outer frame having an overall size of 44mm width x 40mmheight with reinforcement of 1mm thickness and Sash with overall size of 27mm X 53mm with UPVC honeycomb structure inside in lieu of GI reinforcement. Coextruded Glazing bead for fixing of glass shall be of size 9.5mm x 21.5mm. Windows shall be provided with 5mm plain float glass, standard hardware and single point locking system with Crescent Locks. Wall thickness of frame and sash shall be of 2 mm.Maximum possible size 1219mm x 1219mm. (The cost is inclusive of all fixtures and separate charges for minor TandP's shall not be made) (PWD SR for Buildings VOL II for the year 202122. I. No 12.84 P.No 110)Sqm4319.74319.73.96FalseNoneNoneFalseNoneFalse17106.0120
239595971335Nonecode37Providing and fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile throughout the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor TandP's shall not be made) (PWD SR for Buildings VOL II for the year 202122. I. No 12.85 P.No 110)Sqm5113.55113.51.35FalseNoneNoneFalseNoneFalse6903.2250
239596071335Nonecode38Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours and shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement and matching pigments etc. complete. Size of Tile 600x600 mm (PWD SR for Buildings VOL II for the year 202122. I. No 9.17.2 P.No 61)Sqm1157.11157.145.62FalseNoneNoneFalseNoneFalse52786.9020
239596171335Nonecode39Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. (CSR for Buildings VOL II for the year 202122. I. No 9.9 P.No 60)Sqm635.25635.2510.5FalseNoneNoneFalseNoneFalse6670.1250
239596271335Nonecode40Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. (PWD SR for Buildings VOL II for the year 202122. I. No 9.11 P.No 60)Sqm800.1800.120.16FalseNoneNoneFalseNoneFalse16130.0160
239596371335Nonecode41Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. (PWD SR for Buildings VOL II for the year 202122. I. No 9.39 P.No 65)Sqm1088.851088.8532.72FalseNoneNoneFalseNoneFalse35627.1720
239596471335Nonecode42Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m over an under coat of primer applied @ 0.80 ltr/10 m of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineerincharge. (PWD SR for Buildings VOL II for the year 202122. I. No 8.33.3 P.No 47)Sqm111.3111.35.31FalseNoneNoneFalseNoneFalse591.0030
239596571335Nonecode43Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m over and including one coat of Special primer applied @ 0.75 ltr /10 m with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineerincharge. (PWD SR for Buildings VOL II for the year 202122. I. No 8.33.1 P.No 46)Sqm123.9123.9194.91FalseNoneNoneFalseNoneFalse24149.3490
239596671335Nonecode44Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m over and including one coat of Special primer applied @ 0.75 ltr /10 m with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineerincharge. (PWD SR for Buildings VOL II for the year 202122. I. No 8.33.1 P.No 46)Sqm123.9123.963.82FalseNoneNoneFalseNoneFalse7907.2980
239596771335Nonecode45Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m over and including riming coat of exterior primer applied @ 2.20 kg/10 m) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineerincharge. (PWD SR for Buildings VOL II for the year 202122. I. No 8.30 P.No 46)Sqm142.8142.8203.94FalseNoneNoneFalseNoneFalse29122.6320
239596871335Nonecode46Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the EngineerinCharge.(CSR, 202122, VOLII,Item No 11.2, Pg. No 75 As per 4th Quarter Issue Rate).Kg106.05106.05189.55FalseNoneNoneFalseNoneFalse20101.77750
239596971335Nonecode47Providing and fixing UV stabilised fiberglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated 'J' or 'L' hooks, bolts and nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% ultraviolet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. 2 mm thick Flat (PWD SR for Buildings VOL II for the year 202122. I. No 7.33.2 P.No 26)Sqm927.15927.1521.0FalseNoneNoneFalseNoneFalse19470.150
239597071335Nonecode48Providing ThermoMechanically Treated bars of grade Fe550 or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) (CSR for Buildings VOL II for the year 202122. I. No 11.32 P.No 84)Kg96.696.63006.16FalseNoneNoneFalseNoneFalse290395.0560
239597171335Nonecode49Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of the slab = 0.50 m2 CSR for the year 202122. No10.1.1 P.No68Sqm3624.63624.61.2FalseNoneNoneFalseNoneFalse4349.520
239597271335Nonecode50Providing and fixing kitchen sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P. brass waste complete, including painting the fittings and brackets, cutting and making good the walls wherever required: White glazed fire clay kitchen sink of size 600x450x 250 mm CSR for the year 202122. No14.9.1 P.No125Each2640.752640.751.0FalseNoneNoneFalseNoneFalse2640.750
239597371335Nonecode51Providing and laying heavy duty cobble stones 60mm thick interlock pavers, using cement and course sand for manufacture of blocks of approved size, shape and colour with a minimum compressive strength of 281 kg per m2 over 50mm thick sand bed ( average thickness ) and compacting with plate vibrator having 3 tons compaction force thereby forcing part of sand underneath to come up in between joints, final compaction of paver surface joints into its final level , including cost of materials, labour and Usage charges of machinery complete as per specifications. (CSR for Buildings VOL II for the year 202122. I. No 9.31 P.No64)Kg1141.351141.3518.0FalseNoneNoneFalseNoneFalse20544.30
239597471335Nonecode52Supplying heavy gauge PVC conduit pipe 19/20 mm dia 2 mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. (PWD Part I Electrical Works SR for the year 202223. I. No 1.1.1 P.No 01 of 47 )m68.068.040.0FalseNoneNoneFalseNoneFalse2720.00
239597571335Nonecode53Providing and placing on terrace (on all floor levels), polyethylene water storage tanks IS: 12701 marked, with cover and suitable locking arrangements and making necessary holes for inlet, outlet and over flow pipes but without fittings and the base support for tank (PWD SR for Buildings VOL II for the year 202122. I. No 13.34 1st Addenda w.e.f 21.04.2022)Ltr8.48.4500.0FalseNoneNoneFalseNoneFalse4200.00
239597671335Nonecode54Supplying PVC ring tight pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and (WS and UGD Works CSR for the year 202122. No 1.7 SOR CODE : M010G P.No134)m413.7413.75.0FalseNoneNoneFalseNoneFalse2068.50
239597771335Nonecode5540MM Dia Pipe over terrace distribution from Tankm492.45492.455.0FalseNoneNoneFalseNoneFalse2462.250
239597871335Nonecode5625mm dia Pipe in W/Cm499.8499.820.0FalseNoneNoneFalseNoneFalse9996.00
239597971335Nonecode5720mm dia Pipe in W/Cm391.65391.653.0FalseNoneNoneFalseNoneFalse1174.950
239598071335Nonecode58Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15mm C.P. brass pillar tap (PWD SR for Buildings VOL II for the year 202122. I. No 14.7.2 Page No 124)Each2263.82263.81.0FalseNoneNoneFalseNoneFalse2263.80
239598171335Nonecode59Providing and fixing brass bib cock of approved quality : 15 mm nominal bore (PWD SR for Buildings VOL II for the year 202122. I. No 13.2.1 Page No 115)No342.3342.33.0FalseNoneNoneFalseNoneFalse1026.90
239598271335Nonecode60Providing and fixing white vitreous china water closet squatting pan (Indian type) : 14.13.1 Long pattern W.C. pan of size 580 mm (PWD SR for Buildings VOL II for the year 202122. I. No 14.13.1 P.No 126)Each1210.651210.652.0FalseNoneNoneFalseNoneFalse2421.30
239598371335Nonecode61Constructing brick masonry chamber of internal dimension 600x600 mm and depth of 600 mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150 mm thick with 1:3:6, lastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75 mm thick for fixing CI cover and frame etc. excluding the cost of CI frame and cover. WS and UGD Works CSR for the year 202122. No 9 SOR CODE: T130B P.No187No5225.855225.851.0FalseNoneNoneFalseNoneFalse5225.850
239598471335Nonecode62Concealed Conduit System Supplying heavy gauge PVC conduit pipe ……mm dia .......mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary (Elec SR 202223) P.No2, I.No1.2 (1.2.2) (25mm dia 2mm thick)Mtr70.070.015.0FalseNoneNoneFalseNoneFalse1050.00
239598571335Nonecode63Supplying heavy gauge PVC Conduit Pipe ….dia .......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. (Elec SR 202223) P.No2, I.No1.3 (1.3.2) (25mm dia 2mm thick)(Groove)Mtr80.080.015.0FalseNoneNoneFalseNoneFalse1200.00
239598671335Nonecode64Supplying and fixing PVC/metal conduit Deep junction box (Elec SR 202223)P.No2 and 3, I.No1.5(1.5.2) (25mm dia 2mm thick)Mtr51.051.08.0FalseNoneNoneFalseNoneFalse408.00
239598771335Nonecode65Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, Finishing with necessary cement plastering complete. (Elec SR 202223)P.No3, I.No1.6 (1,6.3) (10"x7"x3")Each101.0101.02.0FalseNoneNoneFalseNoneFalse202.00
239598871335Nonecode66Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, Finishing with necessary cement plastering complete. (Elec SR 202223)P.No3, I.No1.6 (1,6.4) (8"x6"x3")Each75.075.02.0FalseNoneNoneFalseNoneFalse150.00
239598971335Nonecode67Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, Finishing with necessary cement plastering complete. (Elec SR 202223)P.No3, I.No1.6 (1,6.5) (4"x4"x3")Each69.069.02.0FalseNoneNoneFalseNoneFalse138.00
239599071335Nonecode68Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, Finishing with necessary cement plastering complete. (Elec SR 202223)P.No3, I.No1.6.2 (Fan Box)No105.0105.03.0FalseNoneNoneFalseNoneFalse315.00
239599171335Nonecode69Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP A (Elec SR 202223)P.No5, I.No2.1 (2.1.1) (Point Wiring)Point276.0276.03.0FalseNoneNoneFalseNoneFalse828.00
239599271335Nonecode70Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP A. Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch (Elec SR 202223)P.No5, I.No2.1 (2.1.2) (Point Wiring)Point386.0386.03.0FalseNoneNoneFalseNoneFalse1158.00
239599371335Nonecode71Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP A. Long point above 6Mtr upto 10Mtr from tapping point to out let via switch(Elec SR 202223)P.No5, I.No2.1 (2.1.3) (Point Wiring)Point567.0567.06.0FalseNoneNoneFalseNoneFalse3402.00
239599471335Nonecode72Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS694:1990 and confirming to GTP of GROUP A. (Elec SR 202223)P.No6, I.No2.5 (2.5.2) (1.5 Sq.mm)Mtr69.069.012.0FalseNoneNoneFalseNoneFalse828.00
239599571335Nonecode73Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS694:1990 and confirming to GTP of GROUP A.(Elec SR 202223)P.No6, I.No2.5 (2.5.3) (2.5 Sq.mm)Mtr88.088.012.0FalseNoneNoneFalseNoneFalse1056.00
239599671335Nonecode74Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS694:1990 and confirming to GTP of GROUP A. (Elec SR 202223)P.No6, I.No2.5 (2.5.4) (4 Sq.mm)Mtr112.0112.012.0FalseNoneNoneFalseNoneFalse1344.00
239599771335Nonecode75Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS694:1990 and confirming to GTP of GROUP A. (Elec SR 202223)P.No6, I.No2.5 (2.5.5) (6 Sq.mm)Mtr158.0158.012.0FalseNoneNoneFalseNoneFalse1896.00
239599871335Nonecode76Supplying 6A flush type socket and 6 amps flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 ((Elec SR 202223)P.No15, I.No3.1 (3.1.2) (6A 'U' Socket)Each143.0143.03.0FalseNoneNoneFalseNoneFalse429.00
239599971335Nonecode77Supplying and fixing/replacing of 6/16/32Amps electrical accessories on existing switch board. GROUP A (Elec SR 202223)P.No18, I.No3.15 (3.1.1) (6A Switches)Each121.0121.03.0FalseNoneNoneFalseNoneFalse363.00
239600071335Nonecode78Supplying and mounting 2 No of 2 way 6 amps flush type switches either surface/flush mounted on existing gang box or in 4mm thick plastic sheet and mounted on a flush mounted wooden box and wiring as per IS 1293 (Elec SR 202223) P.No15, I.No3.2 (2Way Switches)Each162.0162.01.0FalseNoneNoneFalseNoneFalse162.00
239600171335Nonecode79Supply and fixing of Bakelite D.P/Socket/ switch with/without neon indicator over existing wood board or flush mounting in plastic plates/nitches as per IS 1293 and IS 3854 GROUP A(Elec SR 202223)P.No15, I.No3.3 (3.3..1) (32 A Flush type DP's)Each91.091.01.0FalseNoneNoneFalseNoneFalse91.00
239600271335Nonecode80Supply and fixing of Bakelite D.P/Socket/ switch with/without neon indicator over existing wood board or flush mounting in plastic plates/nitches as per IS 1293 and IS 3854 GROUP A (Elec SR 202223) P.No15, I.No3.3 (3.3.3) (16A 'U' Socket)Each149.0149.01.0FalseNoneNoneFalseNoneFalse149.00
239600371335Nonecode81Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS3741979 and with double ball bearing system. 48" Sweep (1200mm) (Elec SR 202223) P.No78, I.No6.3 (6.3.1) (Ceiling Fan)Each2085.02085.01.0FalseNoneNoneFalseNoneFalse2085.00
239600471335Nonecode82Supplying and fixing regular MCB distribution boards onwall/ood board / flush mounting using required clA, bolts,nuts etc., with provision for fixing suitable type capacityMCB's single phase/3 phase/single door with powder coatedpainting Made out of 14 SWG MS enclosure.(Elec SR 202223) P.No47, I.No5.18.12 6 Way TP and NEach3735.03735.01.0FalseNoneNoneFalseNoneFalse3735.00
239600571335Nonecode83Supplying and fixing of retrofit type LED bulb ...... W withOPAL acrylic diffuser comprising of LED source with CCT 6500degree K, CRImore than 70%. efficacy more than80 lumen per W, lifemore than 25000burning hours and Compliance to IS 10322/IEC 60598, LM 79and LM 80. The LED are driven by HF electronic driver integratedin the system, with PF more than 0.95, power loss should less than 5% of lampWage., short circuit and open circuit protection to be integratedin the circuit, THD less than 20%, Life as per LM 79. Theoperating input voltage should be between 130 to 275 V. BISApproved and Tested by NABL/CPRI accredited laboratorywith 2 years Warranty against any manufacturing defect working under standard electrical condition.(Elec SR 202223) P.No38 ITEM No 11.11.7( 18W Bulb)No436.0436.05.0FalseNoneNoneFalseNoneFalse2180.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17068526710000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17068526710000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17068526710000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)NoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneProposals for subcontracting components of works amounting to more than 20% of the contract price (for each, the qualifications and experience of the identified sub-contractor in the relevant fields should be attached)NoneNone
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs.36.00 Lakhs)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Annual Turnover
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Eligible PWD registered contractorTrueTechnical Bid
Last five year Annual Turnover Certificate Achieved in At least Two financial Years an average annual turnover for the amount estimate cost 36.00 LakhsTrueTechnical Bid
Similar Nature of Work Done Certificate achieved at least 50 Percent of Estimate Cost 18.00 LakhsTrueTechnical Bid
Last three Year Income Tax Return CertificateTrueTechnical Bid
GST Registration Certificate and PAN CardTrueTechnical Bid
Line of Credit 30 Percent of the estimate amount 10.80 LakhsTrueTechnical Bid
All Other Condition as per KW-1 Document EnclosedTrueTechnical Bid
tenderWorkLocationList
tenderSubEstimateNamedistrictNametaluqNameloksabhaContNameassemblyContNamelocationDescriptionlatitudeDegreeslatitudeMinuteslatitudeSecondslongitudeDegreeslongitudeMinuteslongitudeSeconds
BuildingsKalaburagiKamalapuraGulbargaKAMALAPUR (SC)In ward no 2 of Kamalapura townNoneNoneNoneNoneNoneNone
BuildingsKalaburagiKamalapuraGulbargaKAMALAPUR (SC)In Ward no 05NoneNoneNoneNoneNoneNone
tenderAddressNone
tenderRecallDTONone