createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1706854399338
version4
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee750.00
emd90000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose19-02-2024 17:30:00
tenderQueryClose17-02-2024 17:30:00
technicalBidOpen21-02-2024 11:00:00
publishedDate02-02-2024 17:53:32
publishedByPostDUDC_PD_KLB
publishedByUserKPE16973 - MUNAWAR DOWLA
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonRamchandra Katke
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber9740339572
tenderSupplierListNone
tenderSchedule
createdTs1706854399361
version6
createdDateNone
modifiedDateNone
tenderNumberDMA/2023-24/BD/WORK_INDENT12445
titlePackage-3 1) Construction of anganwadi building at Haji Server Tanda in sedam Town 2) Construction of Anganwadi building at Miskinpura in Sedam town
descriptionPackage-3 1) Construction of anganwadi building at Haji Server Tanda in sedam Town 2) Construction of Anganwadi building at Miskinpura in Sedam town
categoryWORKS
categoryTextWorks
ecv2974049.70
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2188
locationNameDMA District Urban Development Cell Kalaburagi
provisionalAmount3600000.0
groupOverheadTotalNone
fileNumberNO/KKRDB/2022-23/TMCSEDAM/3
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17068543990000NoneNoneBuildingsPackage-3 1) Construction of anganwadi building at Haji Server Tanda in sedam Town1487024.85
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
239723071377None001Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. In area of light jungleSqm165946.2165946.20.005FalseNoneNoneFalseNoneFalse829.7310
239723171377None002Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 mCum76.6576.6567.18FalseNoneNoneFalseNoneFalse5149.3470
239723271377None003Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregatesCum5466.35466.36.18FalseNoneNoneFalseNoneFalse33781.7340
239723371377None004Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum4987.54987.518.39FalseNoneNoneFalseNoneFalse91720.1250
239723471377None005Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum5619.65619.612.38FalseNoneNoneFalseNoneFalse69570.6480
239723571377None006Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 design mix Using 20mm nominal size graded crushed coarse aggregatesCum6240.156240.155.83FalseNoneNoneFalseNoneFalse36380.07450
239723671377None007Appendix I Additionalities for Formwork, Centering & Scaffolding Foundation upto Plinth b. All other typesCum187.2187.25.83FalseNoneNoneFalseNoneFalse1091.3760
239723771377None008Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 design mix Using 20mm nominal size graded crushed coarse aggregatesCum6491.16491.12.17FalseNoneNoneFalseNoneFalse14085.6870
239723871377None009Appendix I Additionalities for Formwork, Centering & Scaffolding Columns & PiersCum4543.774543.772.17FalseNoneNoneFalseNoneFalse9859.98090
239723971377None010Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 design mix Using 20mm nominal size graded crushed coarse aggregatesCum6491.16491.17.29FalseNoneNoneFalseNoneFalse47320.1190
239724071377None011Appendix I Additionalities for Formwork, Centering & Scaffolding Beams & Lintels of BuildingCum3894.663894.667.29FalseNoneNoneFalseNoneFalse28392.07140
239724171377None012Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 design mix Using 20mm nominal size graded crushed coarse aggregatesCum6491.16491.18.31FalseNoneNoneFalseNoneFalse53941.0410
239724271377None013Appendix I Additionalities for Formwork, Centering & ScaffoldingRoof (Straight & Arched)Cum3245.553245.558.31FalseNoneNoneFalseNoneFalse26970.52050
239724371377None014Supplying, Fitting and Placing TMT Fe 500 & above Reinforcement in Foundation / Substructure /Superstructure complete as per Drawing and Technical Specifications.Tonne84311.8584311.852.32FalseNoneNoneFalseNoneFalse195603.4920
239724471377None015Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum7295.47295.432.04FalseNoneNoneFalseNoneFalse233744.6160
239724571377None016Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications.Cum79111.279111.20.576FalseNoneNoneFalseNoneFalse45568.05120
239724671377None017Providing and fixing in position fully panelled Mathi/Nandi wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures)Sqm4783.84783.813.86FalseNoneNoneFalseNoneFalse66303.4680
239724771377None018Providing and fixing in position Mathi/Nandi wood fully panelled shutters for windows with stiles and rails of 35mm. thick, 75mm wide in two halves with panels of 25mm thick including cost of materials, labour charges, usage charges complete as per specifications. (excluding cost of fixtures)Sqm4856.254856.2510.8FalseNoneNoneFalseNoneFalse52447.50
239724871377None019Providing and fixing Structural Steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kg101.85101.85226.8FalseNoneNoneFalseNoneFalse23099.580
239724971377None020Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.Each1555.051555.056.0FalseNoneNoneFalseNoneFalse9330.30
239725071377None021Fixing of window frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debries with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.Each1057.351057.357.0FalseNoneNoneFalseNoneFalse7401.450
239725171377None022Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm207.9207.940.09FalseNoneNoneFalseNoneFalse8334.7110
239725271377None023Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm322.35322.35321.15FalseNoneNoneFalseNoneFalse103522.70250
239725371377None024Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent.Sqm3013.53013.537.69FalseNoneNoneFalseNoneFalse113578.8150
239725471377None025Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete.Sqm800.1800.12.2FalseNoneNoneFalseNoneFalse1760.220
239725571377None026Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.Sqm1088.851088.8513.09FalseNoneNoneFalseNoneFalse14253.04650
239725671377None027Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm110.25110.25148.38FalseNoneNoneFalseNoneFalse16358.8950
239725771377None028Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm69.369.3125.6FalseNoneNoneFalseNoneFalse8704.080
239725871377None029Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m over an under coat of primer applied @0.75 ltr/10 m of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm110.25110.2555.48FalseNoneNoneFalseNoneFalse6116.670
239725971377None030Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m over an under coat of primer applied @ 0.80 ltr/10 m of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm111.3111.310.8FalseNoneNoneFalseNoneFalse1202.040
239726071377None031Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lidEach5255.255255.251.0FalseNoneNoneFalseNoneFalse5255.250
239726171377None032Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: using White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixerEach3778.953778.952.0FalseNoneNoneFalseNoneFalse7557.90
239726271377None033Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040 mm bowl depth 250 mmEach5218.55218.51.0FalseNoneNoneFalseNoneFalse5218.50
239726371377None034Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 1500x450 mmEach1549.81549.82.0FalseNoneNoneFalseNoneFalse3099.60
239726471377None035Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.Each4057.24057.27.0FalseNoneNoneFalseNoneFalse28400.40
239726571377None036Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:PVC pipes 110mm dia., 6 kg/sqcm & class 3Mtr413.7413.750.0FalseNoneNoneFalseNoneFalse20685.00
239726671377None037Providing and fixing unplasticised PVC connection pipe with brass unions :20 mm nominal boreNos133.35133.3535.0FalseNoneNoneFalseNoneFalse4667.250
239726771377None038Providing and fixing brss bib cock of approved quality etc.,Nos362.25362.254.0FalseNoneNoneFalseNoneFalse1449.00
239726871377None039Supplying and fixing polyethylene water storage tanks etc. complete tedNos7875.07875.01.0FalseNoneNoneFalseNoneFalse7875.00
239726971377None040Concealed Conduit System Supplying heavy gauge PVC conduit pipe ……mm dia .......mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25mm dia 2mm thickMtr73.573.555.0FalseNoneNoneFalseNoneFalse4042.50
239727071377None041Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.25 mm dia 2 mm thickMtr84.084.055.0FalseNoneNoneFalseNoneFalse4620.00
239727171377None042Supplying and fixing PVC/metal conduit Deep junction box 25 mm deep Junction boxEach53.5553.5530.0FalseNoneNoneFalseNoneFalse1606.50
239727271377None043Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, Finishing with necessary cement plastering complete.10" x 7" x 3" (254 x 178 x 76 mm)Each106.05106.054.0FalseNoneNoneFalseNoneFalse424.20
239727371377None044Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, Finishing with necessary cement plastering complete.8" x 6" x 3" (203 x 152 x 76 mm)Each78.7578.754.0FalseNoneNoneFalseNoneFalse315.00
239727471377None045Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, Finishing with necessary cement plastering complete.4" x 4" x 3" ( 101 x 101 x 76 mmEach72.4572.454.0FalseNoneNoneFalseNoneFalse289.80
239727571377None046Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, Finishing with necessary cement plastering complete. 12" x 9" x 3" (300 x 228 x 76 mm)Each110.25110.253.0FalseNoneNoneFalseNoneFalse330.750
239727671377None047Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP A Short point upto 3m from tapping point to out let via switchPoint289.8289.86.0FalseNoneNoneFalseNoneFalse1738.80
239727771377None048Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP A Medium point above 3m upto 6m from tapping point to out let via switchPoint405.3405.36.0FalseNoneNoneFalseNoneFalse2431.80
239727871377None049Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP A Long point above 6m upto 10m from tapping point to out let via switchPoint595.35595.3512.0FalseNoneNoneFalseNoneFalse7144.20
239727971377None050Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of 3C X 1.5 mm2Mtr72.4572.4555.0FalseNoneNoneFalseNoneFalse3984.750
239728071377None051Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of 4C x 1.5 mm2Mtr92.492.455.0FalseNoneNoneFalseNoneFalse5082.00
239728171377None052Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of 6C x 1.5 mm2Mtr117.6117.655.0FalseNoneNoneFalseNoneFalse6468.00
239728271377None053Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of 8C x 1.5 mm2Mtr165.9165.955.0FalseNoneNoneFalseNoneFalse9124.50
239728371377None054Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 6A 3/5 WayEach150.15150.156.0FalseNoneNoneFalseNoneFalse900.90
239728471377None055Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 6A 2 WayEach127.05127.056.0FalseNoneNoneFalseNoneFalse762.30
239728571377None056Supplying and mounting 2 Nos. of 2Way 6 A flush type switches either surface/flush mounted on existing gang box or in 4mm thick plastic sheet and mounted on a flush mounted wooden box and wiring as per IS 1293Each170.1170.16.0FalseNoneNoneFalseNoneFalse1020.60
239728671377None057Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.1-3 WayEach95.5595.554.0FalseNoneNoneFalseNoneFalse382.20
239728771377None058Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 6 WayEach156.45156.454.0FalseNoneNoneFalseNoneFalse625.80
239728871377None059Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles.Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system.48" Sweep (1200 mm) Regular modelEach2189.252189.254.0FalseNoneNoneFalseNoneFalse8757.00
239728971377None060Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts,nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure III - Double Door 6 Way TP & NEach3921.753921.753.0FalseNoneNoneFalseNoneFalse11765.250
239729071377None061Supplying and fixing of retrofit type - LED bulb ...... W withOPAL acrylic diffuser comprising of LED source with CCT 6500degree K, CRImore than 70%. efficacy more than80 lumen per W, lifemore than 25000burning hours and Compliance to IS 10322/IEC 60598, LM 79and LM 80. The LED are driven by HF electronic driver integratedin the system, with PF more than 0.95, power loss should less than 5% of lampWage., short circuit and open circuit protection to be integratedin the circuit, THD less than 20%, Life as per LM 79. Theoperating input voltage should be between 130 to 275 V. BISApproved and Tested by NABL/CPRI accredited laboratorywith 2 years Warranty against any manufacturing defect working under standard electrical condition.(Elec SR -2022-23) P.No.38 ITEM NO. 11.11.7( 18W Bulb)Each457.8457.810.0FalseNoneNoneFalseNoneFalse4578.00
17068543990000NoneNoneBuildingsPackage-3 Construction of Aganwadi Building at Miskinpur in Sedam Town1487024.85
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
239729171378None001Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. In area of light jungleSqm165946.2165946.20.005FalseNoneNoneFalseNoneFalse829.7310
239729271378None002Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 mCum76.6576.6567.18FalseNoneNoneFalseNoneFalse5149.3470
239729371378None003Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregatesCum5466.35466.36.18FalseNoneNoneFalseNoneFalse33781.7340
239729471378None004Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum4987.54987.518.39FalseNoneNoneFalseNoneFalse91720.1250
239729571378None005Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum5619.65619.612.38FalseNoneNoneFalseNoneFalse69570.6480
239729671378None006Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 design mix Using 20mm nominal size graded crushed coarse aggregatesCum6240.156240.155.83FalseNoneNoneFalseNoneFalse36380.07450
239729771378None007Appendix I Additionalities for Formwork, Centering & Scaffolding Foundation upto Plinth b. All other typesCum187.2187.25.83FalseNoneNoneFalseNoneFalse1091.3760
239729871378None008Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 design mix Using 20mm nominal size graded crushed coarse aggregatesCum6491.16491.12.17FalseNoneNoneFalseNoneFalse14085.6870
239729971378None009Appendix I Additionalities for Formwork, Centering & Scaffolding Columns & PiersCum4543.774543.772.17FalseNoneNoneFalseNoneFalse9859.98090
239730071378None010Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 design mix Using 20mm nominal size graded crushed coarse aggregatesCum6491.16491.17.29FalseNoneNoneFalseNoneFalse47320.1190
239730171378None011Appendix I Additionalities for Formwork, Centering & Scaffolding Beams & Lintels of BuildingCum3894.663894.667.29FalseNoneNoneFalseNoneFalse28392.07140
239730271378None012Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 design mix Using 20mm nominal size graded crushed coarse aggregatesCum6491.16491.18.31FalseNoneNoneFalseNoneFalse53941.0410
239730371378None013Appendix I Additionalities for Formwork, Centering & ScaffoldingRoof (Straight & Arched)Cum3245.553245.558.31FalseNoneNoneFalseNoneFalse26970.52050
239730471378None014Supplying, Fitting and Placing TMT Fe 500 & above Reinforcement in Foundation / Substructure /Superstructure complete as per Drawing and Technical Specifications.Tonne84311.8584311.852.32FalseNoneNoneFalseNoneFalse195603.4920
239730571378None015Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum7295.47295.432.04FalseNoneNoneFalseNoneFalse233744.6160
239730671378None016Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications.Cum79111.279111.20.576FalseNoneNoneFalseNoneFalse45568.05120
239730771378None017Providing and fixing in position fully panelled Mathi/Nandi wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures)Sqm4783.84783.813.86FalseNoneNoneFalseNoneFalse66303.4680
239730871378None018Providing and fixing in position Mathi/Nandi wood fully panelled shutters for windows with stiles and rails of 35mm. thick, 75mm wide in two halves with panels of 25mm thick including cost of materials, labour charges, usage charges complete as per specifications. (excluding cost of fixtures)Sqm4856.254856.2510.8FalseNoneNoneFalseNoneFalse52447.50
239730971378None019Providing and fixing Structural Steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kg101.85101.85226.8FalseNoneNoneFalseNoneFalse23099.580
239731071378None020Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.Each1555.051555.056.0FalseNoneNoneFalseNoneFalse9330.30
239731171378None021Fixing of window frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debries with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.Each1057.351057.357.0FalseNoneNoneFalseNoneFalse7401.450
239731271378None022Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm207.9207.940.09FalseNoneNoneFalseNoneFalse8334.7110
239731371378None023Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm322.35322.35321.15FalseNoneNoneFalseNoneFalse103522.70250
239731471378None024Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent.Sqm3013.53013.537.69FalseNoneNoneFalseNoneFalse113578.8150
239731571378None025Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete.Sqm800.1800.12.2FalseNoneNoneFalseNoneFalse1760.220
239731671378None026Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.Sqm1088.851088.8513.09FalseNoneNoneFalseNoneFalse14253.04650
239731771378None027Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm110.25110.25148.38FalseNoneNoneFalseNoneFalse16358.8950
239731871378None028Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm69.369.3125.6FalseNoneNoneFalseNoneFalse8704.080
239731971378None029Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m over an under coat of primer applied @0.75 ltr/10 m of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm110.25110.2555.48FalseNoneNoneFalseNoneFalse6116.670
239732071378None030Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m over an under coat of primer applied @ 0.80 ltr/10 m of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm111.3111.310.8FalseNoneNoneFalseNoneFalse1202.040
239732171378None031Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lidEach5255.255255.251.0FalseNoneNoneFalseNoneFalse5255.250
239732271378None032Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: using White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixerEach3778.953778.952.0FalseNoneNoneFalseNoneFalse7557.90
239732371378None033Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040 mm bowl depth 250 mmEach5218.55218.51.0FalseNoneNoneFalseNoneFalse5218.50
239732471378None034Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 1500x450 mmEach1549.81549.82.0FalseNoneNoneFalseNoneFalse3099.60
239732571378None035Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.Each4057.24057.27.0FalseNoneNoneFalseNoneFalse28400.40
239732671378None036Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:PVC pipes 110mm dia., 6 kg/sqcm & class 3Mtr413.7413.750.0FalseNoneNoneFalseNoneFalse20685.00
239732771378None037Providing and fixing unplasticised PVC connection pipe with brass unions :20 mm nominal boreNos133.35133.3535.0FalseNoneNoneFalseNoneFalse4667.250
239732871378None038Providing and fixing brss bib cock of approved quality etc.,Nos362.25362.254.0FalseNoneNoneFalseNoneFalse1449.00
239732971378None039Supplying and fixing polyethylene water storage tanks etc. complete tedNos7875.07875.01.0FalseNoneNoneFalseNoneFalse7875.00
239733071378None040Concealed Conduit System Supplying heavy gauge PVC conduit pipe ……mm dia .......mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25mm dia 2mm thickMtr73.573.555.0FalseNoneNoneFalseNoneFalse4042.50
239733171378None041Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.25 mm dia 2 mm thickMtr84.084.055.0FalseNoneNoneFalseNoneFalse4620.00
239733271378None042Supplying and fixing PVC/metal conduit Deep junction box 25 mm deep Junction boxEach53.5553.5530.0FalseNoneNoneFalseNoneFalse1606.50
239733371378None043Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, Finishing with necessary cement plastering complete.10" x 7" x 3" (254 x 178 x 76 mm)Each106.05106.054.0FalseNoneNoneFalseNoneFalse424.20
239733471378None044Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, Finishing with necessary cement plastering complete.8" x 6" x 3" (203 x 152 x 76 mm)Each78.7578.754.0FalseNoneNoneFalseNoneFalse315.00
239733571378None045Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, Finishing with necessary cement plastering complete.4" x 4" x 3" ( 101 x 101 x 76 mmEach72.4572.454.0FalseNoneNoneFalseNoneFalse289.80
239733671378None046Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, Finishing with necessary cement plastering complete. 12" x 9" x 3" (300 x 228 x 76 mm)Each110.25110.253.0FalseNoneNoneFalseNoneFalse330.750
239733771378None047Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP A Short point upto 3m from tapping point to out let via switchPoint289.8289.86.0FalseNoneNoneFalseNoneFalse1738.80
239733871378None048Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP A Medium point above 3m upto 6m from tapping point to out let via switchPoint405.3405.36.0FalseNoneNoneFalseNoneFalse2431.80
239733971378None049Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP A Long point above 6m upto 10m from tapping point to out let via switchPoint595.35595.3512.0FalseNoneNoneFalseNoneFalse7144.20
239734071378None050Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of 3C X 1.5 mm2Mtr72.4572.4555.0FalseNoneNoneFalseNoneFalse3984.750
239734171378None051Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of 4C x 1.5 mm2Mtr92.492.455.0FalseNoneNoneFalseNoneFalse5082.00
239734271378None052Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of 6C x 1.5 mm2Mtr117.6117.655.0FalseNoneNoneFalseNoneFalse6468.00
239734371378None053Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of 8C x 1.5 mm2Mtr165.9165.955.0FalseNoneNoneFalseNoneFalse9124.50
239734471378None054Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 6A 3/5 WayEach150.15150.156.0FalseNoneNoneFalseNoneFalse900.90
239734571378None055Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 6A 2 WayEach127.05127.056.0FalseNoneNoneFalseNoneFalse762.30
239734671378None056Supplying and mounting 2 Nos. of 2Way 6 A flush type switches either surface/flush mounted on existing gang box or in 4mm thick plastic sheet and mounted on a flush mounted wooden box and wiring as per IS 1293Each170.1170.16.0FalseNoneNoneFalseNoneFalse1020.60
239734771378None057Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.1-3 WayEach95.5595.554.0FalseNoneNoneFalseNoneFalse382.20
239734871378None058Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 6 WayEach156.45156.454.0FalseNoneNoneFalseNoneFalse625.80
239734971378None059Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles.Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system.48" Sweep (1200 mm) Regular modelEach2189.252189.254.0FalseNoneNoneFalseNoneFalse8757.00
239735071378None060Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts,nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure III - Double Door 6 Way TP & NEach3921.753921.753.0FalseNoneNoneFalseNoneFalse11765.250
239735171378None061Supplying and fixing of retrofit type - LED bulb ...... W withOPAL acrylic diffuser comprising of LED source with CCT 6500degree K, CRImore than 70%. efficacy more than80 lumen per W, lifemore than 25000burning hours and Compliance to IS 10322/IEC 60598, LM 79and LM 80. The LED are driven by HF electronic driver integratedin the system, with PF more than 0.95, power loss should less than 5% of lampWage., short circuit and open circuit protection to be integratedin the circuit, THD less than 20%, Life as per LM 79. Theoperating input voltage should be between 130 to 275 V. BISApproved and Tested by NABL/CPRI accredited laboratorywith 2 years Warranty against any manufacturing defect working under standard electrical condition.(Elec SR -2022-23) P.No.38 ITEM NO. 11.11.7( 18W Bulb)Each457.8457.810.0FalseNoneNoneFalseNoneFalse4578.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17068544010000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17068544010000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17068544010000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)NoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneProposals for subcontracting components of works amounting to more than 20% of the contract price (for each, the qualifications and experience of the identified sub-contractor in the relevant fields should be attached)NoneNone
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. 36.00 Lakhs)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- financial turnover
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Eligible PWD registered contractorTrueTechnical Bid
Last five year Annual Turnover Certificate Achieved in At least Two financial Years an average annual turnover for the amount estimate cost 36.00 LakhsTrueTechnical Bid
Similar Nature of Work Done Certificate achieved at least 50 Percent of Estimate Cost 18.00 LakhsTrueTechnical Bid
Last three Year Income Tax Return CertificateTrueTechnical Bid
GST Registration Certificate and PAN CardTrueTechnical Bid
Line of Credit 30 Percent of the estimate amount 10.80 LakhsTrueTechnical Bid
All Other Condition as per KW-1 Document EnclosedTrueTechnical Bid
tenderWorkLocationList
tenderSubEstimateNamedistrictNametaluqNameloksabhaContNameassemblyContNamelocationDescriptionlatitudeDegreeslatitudeMinuteslatitudeSecondslongitudeDegreeslongitudeMinuteslongitudeSeconds
BuildingsKalaburagiSedamGulbargaSEDAMSEDAMNoneNoneNoneNoneNoneNone
BuildingsKalaburagiSedamGulbargaSEDAMSEDAMNoneNoneNoneNoneNoneNone
tenderAddressNone
tenderRecallDTONone