tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1706853412000 | 0 | None | None | Buildings | Package-2 1) Construction of anganwadi building at lohargalli in sedam Town | 1487024.85 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2396607 | 71354 | None | code01 | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. In area of light jungle | Sqm | 165946.2 | 165946.2 | 0.005 | False | None | None | False | None | False | 829.731 | 0 | 2396608 | 71354 | None | code02 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m | Cum | 76.65 | 76.65 | 67.18 | False | None | None | False | None | False | 5149.347 | 0 | 2396609 | 71354 | None | code03 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5466.3 | 5466.3 | 6.18 | False | None | None | False | None | False | 33781.734 | 0 | 2396610 | 71354 | None | code04 | Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 4987.5 | 4987.5 | 18.39 | False | None | None | False | None | False | 91720.125 | 0 | 2396611 | 71354 | None | code05 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 5619.6 | 5619.6 | 12.38 | False | None | None | False | None | False | 69570.648 | 0 | 2396612 | 71354 | None | code06 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 design mix Using 20mm nominal size graded crushed coarse aggregates | Cum | 6240.15 | 6240.15 | 5.83 | False | None | None | False | None | False | 36380.0745 | 0 | 2396613 | 71354 | None | code07 | Appendix I Additionalities for Formwork, Centering & Scaffolding Foundation upto Plinth b. All other types | Cum | 187.2 | 187.2 | 5.83 | False | None | None | False | None | False | 1091.376 | 0 | 2396614 | 71354 | None | code08 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 design mix Using 20mm nominal size graded crushed coarse aggregates | Cum | 6491.1 | 6491.1 | 2.17 | False | None | None | False | None | False | 14085.687 | 0 | 2396615 | 71354 | None | code09 | Appendix I Additionalities for Formwork, Centering & Scaffolding Columns & Piers | Cum | 4543.77 | 4543.77 | 2.17 | False | None | None | False | None | False | 9859.9809 | 0 | 2396616 | 71354 | None | code10 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 design mix Using 20mm nominal size graded crushed coarse aggregates | Cum | 6491.1 | 6491.1 | 7.29 | False | None | None | False | None | False | 47320.119 | 0 | 2396617 | 71354 | None | code11 | Appendix I Additionalities for Formwork, Centering & Scaffolding Beams & Lintels of Building | Cum | 3894.66 | 3894.66 | 7.29 | False | None | None | False | None | False | 28392.0714 | 0 | 2396618 | 71354 | None | code12 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 design mix Using 20mm nominal size graded crushed coarse aggregates | Cum | 6491.1 | 6491.1 | 8.31 | False | None | None | False | None | False | 53941.041 | 0 | 2396619 | 71354 | None | code13 | Appendix I Additionalities for Formwork, Centering & ScaffoldingRoof (Straight & Arched) | Cum | 3245.55 | 3245.55 | 8.31 | False | None | None | False | None | False | 26970.5205 | 0 | 2396620 | 71354 | None | code14 | Supplying, Fitting and Placing TMT Fe 500 & above Reinforcement in Foundation / Substructure /Superstructure complete as per Drawing and Technical Specifications. | Tonne | 84311.85 | 84311.85 | 2.32 | False | None | None | False | None | False | 195603.492 | 0 | 2396621 | 71354 | None | code15 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 7295.4 | 7295.4 | 32.04 | False | None | None | False | None | False | 233744.616 | 0 | 2396622 | 71354 | None | code16 | Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 79111.2 | 79111.2 | 0.576 | False | None | None | False | None | False | 45568.0512 | 0 | 2396623 | 71354 | None | code17 | Providing and fixing in position fully panelled Mathi/Nandi wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures) | Sqm | 4783.8 | 4783.8 | 13.86 | False | None | None | False | None | False | 66303.468 | 0 | 2396624 | 71354 | None | code18 | Providing and fixing in position Mathi/Nandi wood fully panelled shutters for windows with stiles and rails of 35mm. thick, 75mm wide in two halves with panels of 25mm thick including cost of materials, labour charges, usage charges complete as per specifications. (excluding cost of fixtures) | Sqm | 4856.25 | 4856.25 | 10.8 | False | None | None | False | None | False | 52447.5 | 0 | 2396625 | 71354 | None | code19 | Providing and fixing Structural Steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 101.85 | 101.85 | 226.8 | False | None | None | False | None | False | 23099.58 | 0 | 2396626 | 71354 | None | code20 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. | Each | 1555.05 | 1555.05 | 6.0 | False | None | None | False | None | False | 9330.3 | 0 | 2396627 | 71354 | None | code21 | Fixing of window frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debries with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. | Each | 1057.35 | 1057.35 | 7.0 | False | None | None | False | None | False | 7401.45 | 0 | 2396628 | 71354 | None | code22 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 207.9 | 207.9 | 40.09 | False | None | None | False | None | False | 8334.711 | 0 | 2396629 | 71354 | None | code23 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 322.35 | 322.35 | 321.15 | False | None | None | False | None | False | 103522.7025 | 0 | 2396630 | 71354 | None | code24 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. | Sqm | 3013.5 | 3013.5 | 37.69 | False | None | None | False | None | False | 113578.815 | 0 | 2396631 | 71354 | None | code25 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. | Sqm | 800.1 | 800.1 | 2.2 | False | None | None | False | None | False | 1760.22 | 0 | 2396632 | 71354 | None | code26 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. | Sqm | 1088.85 | 1088.85 | 13.09 | False | None | None | False | None | False | 14253.0465 | 0 | 2396633 | 71354 | None | code27 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 110.25 | 110.25 | 148.38 | False | None | None | False | None | False | 16358.895 | 0 | 2396634 | 71354 | None | code28 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 69.3 | 69.3 | 125.6 | False | None | None | False | None | False | 8704.08 | 0 | 2396635 | 71354 | None | code29 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m over an under coat of primer applied @0.75 ltr/10 m of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 110.25 | 110.25 | 55.48 | False | None | None | False | None | False | 6116.67 | 0 | 2396636 | 71354 | None | code30 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m over an under coat of primer applied @ 0.80 ltr/10 m of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 111.3 | 111.3 | 10.8 | False | None | None | False | None | False | 1202.04 | 0 | 2396637 | 71354 | None | code31 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid | Each | 5255.25 | 5255.25 | 1.0 | False | None | None | False | None | False | 5255.25 | 0 | 2396638 | 71354 | None | code32 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: using White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer | Each | 3778.95 | 3778.95 | 2.0 | False | None | None | False | None | False | 7557.9 | 0 | 2396639 | 71354 | None | code33 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040 mm bowl depth 250 mm | Each | 5218.5 | 5218.5 | 1.0 | False | None | None | False | None | False | 5218.5 | 0 | 2396640 | 71354 | None | code34 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 1500x450 mm | Each | 1549.8 | 1549.8 | 2.0 | False | None | None | False | None | False | 3099.6 | 0 | 2396641 | 71354 | None | code35 | Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover. | Each | 4057.2 | 4057.2 | 7.0 | False | None | None | False | None | False | 28400.4 | 0 | 2396642 | 71354 | None | code36 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:PVC pipes 110mm dia., 6 kg/sqcm & class 3 | Mtr | 413.7 | 413.7 | 50.0 | False | None | None | False | None | False | 20685.0 | 0 | 2396643 | 71354 | None | code37 | Providing and fixing unplasticised PVC connection pipe with brass unions :20 mm nominal bore | No | 133.35 | 133.35 | 35.0 | False | None | None | False | None | False | 4667.25 | 0 | 2396644 | 71354 | None | code38 | Providing and fixing brss bib cock of approved quality etc., | No | 362.25 | 362.25 | 4.0 | False | None | None | False | None | False | 1449.0 | 0 | 2396645 | 71354 | None | code39 | Supplying and fixing polyethylene water storage tanks etc. complete ted | No | 7875.0 | 7875.0 | 1.0 | False | None | None | False | None | False | 7875.0 | 0 | 2396646 | 71354 | None | code40 | Concealed Conduit System Supplying heavy gauge PVC conduit pipe ……mm dia .......mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25mm dia 2mm thick | Mtr | 73.5 | 73.5 | 55.0 | False | None | None | False | None | False | 4042.5 | 0 | 2396647 | 71354 | None | code41 | Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.25 mm dia 2 mm thick | Mtr | 84.0 | 84.0 | 55.0 | False | None | None | False | None | False | 4620.0 | 0 | 2396648 | 71354 | None | code42 | Supplying and fixing PVC/metal conduit Deep junction box 25 mm deep Junction box | Each | 53.55 | 53.55 | 30.0 | False | None | None | False | None | False | 1606.5 | 0 | 2396649 | 71354 | None | code43 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, Finishing with necessary cement plastering complete.10" x 7" x 3" (254 x 178 x 76 mm) | Each | 106.05 | 106.05 | 4.0 | False | None | None | False | None | False | 424.2 | 0 | 2396650 | 71354 | None | code44 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, Finishing with necessary cement plastering complete.8" x 6" x 3" (203 x 152 x 76 mm) | Each | 78.75 | 78.75 | 4.0 | False | None | None | False | None | False | 315.0 | 0 | 2396651 | 71354 | None | code45 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, Finishing with necessary cement plastering complete.4" x 4" x 3" ( 101 x 101 x 76 mm | Each | 72.45 | 72.45 | 4.0 | False | None | None | False | None | False | 289.8 | 0 | 2396652 | 71354 | None | code46 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, Finishing with necessary cement plastering complete. 12" x 9" x 3" (300 x 228 x 76 mm) | Each | 110.25 | 110.25 | 3.0 | False | None | None | False | None | False | 330.75 | 0 | 2396653 | 71354 | None | code47 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP A Short point upto 3m from tapping point to out let via switch | Point | 289.8 | 289.8 | 6.0 | False | None | None | False | None | False | 1738.8 | 0 | 2396654 | 71354 | None | code48 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP A Medium point above 3m upto 6m from tapping point to out let via switch | Point | 405.3 | 405.3 | 6.0 | False | None | None | False | None | False | 2431.8 | 0 | 2396655 | 71354 | None | code49 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP A Long point above 6m upto 10m from tapping point to out let via switch | Point | 595.35 | 595.35 | 12.0 | False | None | None | False | None | False | 7144.2 | 0 | 2396656 | 71354 | None | code50 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of 3C X 1.5 mm2 | Mtr | 72.45 | 72.45 | 55.0 | False | None | None | False | None | False | 3984.75 | 0 | 2396657 | 71354 | None | code51 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of 4C x 1.5 mm2 | Mtr | 92.4 | 92.4 | 55.0 | False | None | None | False | None | False | 5082.0 | 0 | 2396658 | 71354 | None | code52 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of 6C x 1.5 mm2 | Mtr | 117.6 | 117.6 | 55.0 | False | None | None | False | None | False | 6468.0 | 0 | 2396659 | 71354 | None | code53 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of 8C x 1.5 mm2 | Mtr | 165.9 | 165.9 | 55.0 | False | None | None | False | None | False | 9124.5 | 0 | 2396660 | 71354 | None | code54 | Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 6A 3/5 Way | Each | 150.15 | 150.15 | 6.0 | False | None | None | False | None | False | 900.9 | 0 | 2396661 | 71354 | None | code55 | Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 6A 2 Way | Each | 127.05 | 127.05 | 6.0 | False | None | None | False | None | False | 762.3 | 0 | 2396662 | 71354 | None | code56 | Supplying and mounting 2 No. of 2Way 6 A flush type switches either surface/flush mounted on existing gang box or in 4mm thick plastic sheet and mounted on a flush mounted wooden box and wiring as per IS 1293 | Each | 170.1 | 170.1 | 6.0 | False | None | None | False | None | False | 1020.6 | 0 | 2396663 | 71354 | None | code57 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.1-3 Way | Each | 95.55 | 95.55 | 4.0 | False | None | None | False | None | False | 382.2 | 0 | 2396664 | 71354 | None | code58 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 6 Way | Each | 156.45 | 156.45 | 4.0 | False | None | None | False | None | False | 625.8 | 0 | 2396665 | 71354 | None | code59 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles.Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system.48" Sweep (1200 mm) Regular model | Each | 2189.25 | 2189.25 | 4.0 | False | None | None | False | None | False | 8757.0 | 0 | 2396666 | 71354 | None | code60 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts,nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure III - Double Door 6 Way TP & N | Each | 3921.75 | 3921.75 | 3.0 | False | None | None | False | None | False | 11765.25 | 0 | 2396667 | 71354 | None | code61 | Supplying and fixing of retrofit type - LED bulb ...... W withOPAL acrylic diffuser comprising of LED source with CCT 6500degree K, CRImore than 70%. efficacy more than80 lumen per W, lifemore than 25000burning hours and Compliance to IS 10322/IEC 60598, LM 79and LM 80. The LED are driven by HF electronic driver integratedin the system, with PF more than 0.95, power loss should less than 5% of lampWage., short circuit and open circuit protection to be integratedin the circuit, THD less than 20%, Life as per LM 79. Theoperating input voltage should be between 130 to 275 V. BISApproved and Tested by NABL/CPRI accredited laboratorywith 2 years Warranty against any manufacturing defect working under standard electrical condition.(Elec SR -2022-23) P.No.38 ITEM NO. 11.11.7( 18W Bulb) | Each | 457.8 | 457.8 | 10.0 | False | None | None | False | None | False | 4578.0 | 0 |
| 1706853412000 | 0 | None | None | Buildings | Package-2 2) Construction of Anganwadi building at kodla cross in Sedam town | 1487024.85 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2396668 | 71355 | None | code01 | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. In area of light jungle | Sqm | 165946.2 | 165946.2 | 0.005 | False | None | None | False | None | False | 829.731 | 0 | 2396669 | 71355 | None | code02 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m | Cum | 76.65 | 76.65 | 67.18 | False | None | None | False | None | False | 5149.347 | 0 | 2396670 | 71355 | None | code03 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5466.3 | 5466.3 | 6.18 | False | None | None | False | None | False | 33781.734 | 0 | 2396671 | 71355 | None | code04 | Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 4987.5 | 4987.5 | 18.39 | False | None | None | False | None | False | 91720.125 | 0 | 2396672 | 71355 | None | code05 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 5619.6 | 5619.6 | 12.38 | False | None | None | False | None | False | 69570.648 | 0 | 2396673 | 71355 | None | code06 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 design mix Using 20mm nominal size graded crushed coarse aggregates | Cum | 6240.15 | 6240.15 | 5.83 | False | None | None | False | None | False | 36380.0745 | 0 | 2396674 | 71355 | None | code07 | Appendix I Additionalities for Formwork, Centering & Scaffolding Foundation upto Plinth b. All other types | Cum | 187.2 | 187.2 | 5.83 | False | None | None | False | None | False | 1091.376 | 0 | 2396675 | 71355 | None | code08 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 design mix Using 20mm nominal size graded crushed coarse aggregates | Cum | 6491.1 | 6491.1 | 2.17 | False | None | None | False | None | False | 14085.687 | 0 | 2396676 | 71355 | None | code09 | Appendix I Additionalities for Formwork, Centering & Scaffolding Columns & Piers | Cum | 4543.77 | 4543.77 | 2.17 | False | None | None | False | None | False | 9859.9809 | 0 | 2396677 | 71355 | None | code10 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 design mix Using 20mm nominal size graded crushed coarse aggregates | Cum | 6491.1 | 6491.1 | 7.29 | False | None | None | False | None | False | 47320.119 | 0 | 2396678 | 71355 | None | code11 | Appendix I Additionalities for Formwork, Centering & Scaffolding Beams & Lintels of Building | Cum | 3894.66 | 3894.66 | 7.29 | False | None | None | False | None | False | 28392.0714 | 0 | 2396679 | 71355 | None | code12 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 design mix Using 20mm nominal size graded crushed coarse aggregates | Cum | 6491.1 | 6491.1 | 8.31 | False | None | None | False | None | False | 53941.041 | 0 | 2396680 | 71355 | None | code13 | Appendix I Additionalities for Formwork, Centering & ScaffoldingRoof (Straight & Arched) | Cum | 3245.55 | 3245.55 | 8.31 | False | None | None | False | None | False | 26970.5205 | 0 | 2396681 | 71355 | None | code14 | Supplying, Fitting and Placing TMT Fe 500 & above Reinforcement in Foundation / Substructure /Superstructure complete as per Drawing and Technical Specifications. | Tonne | 84311.85 | 84311.85 | 2.32 | False | None | None | False | None | False | 195603.492 | 0 | 2396682 | 71355 | None | code15 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 7295.4 | 7295.4 | 32.04 | False | None | None | False | None | False | 233744.616 | 0 | 2396683 | 71355 | None | code16 | Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 79111.2 | 79111.2 | 0.576 | False | None | None | False | None | False | 45568.0512 | 0 | 2396684 | 71355 | None | code17 | Providing and fixing in position fully panelled Mathi/Nandi wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures) | Sqm | 4783.8 | 4783.8 | 13.86 | False | None | None | False | None | False | 66303.468 | 0 | 2396685 | 71355 | None | code18 | Providing and fixing in position Mathi/Nandi wood fully panelled shutters for windows with stiles and rails of 35mm. thick, 75mm wide in two halves with panels of 25mm thick including cost of materials, labour charges, usage charges complete as per specifications. (excluding cost of fixtures) | Sqm | 4856.25 | 4856.25 | 10.8 | False | None | None | False | None | False | 52447.5 | 0 | 2396686 | 71355 | None | code19 | Providing and fixing Structural Steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 101.85 | 101.85 | 226.8 | False | None | None | False | None | False | 23099.58 | 0 | 2396687 | 71355 | None | code20 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. | Each | 1555.05 | 1555.05 | 6.0 | False | None | None | False | None | False | 9330.3 | 0 | 2396688 | 71355 | None | code21 | Fixing of window frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debries with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. | Each | 1057.35 | 1057.35 | 7.0 | False | None | None | False | None | False | 7401.45 | 0 | 2396689 | 71355 | None | code22 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 207.9 | 207.9 | 40.09 | False | None | None | False | None | False | 8334.711 | 0 | 2396690 | 71355 | None | code23 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 322.35 | 322.35 | 321.15 | False | None | None | False | None | False | 103522.7025 | 0 | 2396691 | 71355 | None | code24 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. | Sqm | 3013.5 | 3013.5 | 37.69 | False | None | None | False | None | False | 113578.815 | 0 | 2396692 | 71355 | None | code25 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. | Sqm | 800.1 | 800.1 | 2.2 | False | None | None | False | None | False | 1760.22 | 0 | 2396693 | 71355 | None | code26 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. | Sqm | 1088.85 | 1088.85 | 13.09 | False | None | None | False | None | False | 14253.0465 | 0 | 2396694 | 71355 | None | code27 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 110.25 | 110.25 | 148.38 | False | None | None | False | None | False | 16358.895 | 0 | 2396695 | 71355 | None | code28 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 69.3 | 69.3 | 125.6 | False | None | None | False | None | False | 8704.08 | 0 | 2396696 | 71355 | None | code29 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m over an under coat of primer applied @0.75 ltr/10 m of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 110.25 | 110.25 | 55.48 | False | None | None | False | None | False | 6116.67 | 0 | 2396697 | 71355 | None | code30 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m over an under coat of primer applied @ 0.80 ltr/10 m of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 111.3 | 111.3 | 10.8 | False | None | None | False | None | False | 1202.04 | 0 | 2396698 | 71355 | None | code31 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid | Each | 5255.25 | 5255.25 | 1.0 | False | None | None | False | None | False | 5255.25 | 0 | 2396699 | 71355 | None | code32 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: using White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer | Each | 3778.95 | 3778.95 | 2.0 | False | None | None | False | None | False | 7557.9 | 0 | 2396700 | 71355 | None | code33 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040 mm bowl depth 250 mm | Each | 5218.5 | 5218.5 | 1.0 | False | None | None | False | None | False | 5218.5 | 0 | 2396701 | 71355 | None | code34 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 1500x450 mm | Each | 1549.8 | 1549.8 | 2.0 | False | None | None | False | None | False | 3099.6 | 0 | 2396702 | 71355 | None | code35 | Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover. | Each | 4057.2 | 4057.2 | 7.0 | False | None | None | False | None | False | 28400.4 | 0 | 2396703 | 71355 | None | code36 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:PVC pipes 110mm dia., 6 kg/sqcm & class 3 | Mtr | 413.7 | 413.7 | 50.0 | False | None | None | False | None | False | 20685.0 | 0 | 2396704 | 71355 | None | code37 | Providing and fixing unplasticised PVC connection pipe with brass unions :20 mm nominal bore | Nos | 133.35 | 133.35 | 35.0 | False | None | None | False | None | False | 4667.25 | 0 | 2396705 | 71355 | None | code38 | Providing and fixing brss bib cock of approved quality etc., | Nos | 362.25 | 362.25 | 4.0 | False | None | None | False | None | False | 1449.0 | 0 | 2396706 | 71355 | None | code39 | Supplying and fixing polyethylene water storage tanks etc. complete ted | Nos | 7875.0 | 7875.0 | 1.0 | False | None | None | False | None | False | 7875.0 | 0 | 2396707 | 71355 | None | code40 | Concealed Conduit System Supplying heavy gauge PVC conduit pipe ……mm dia .......mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25mm dia 2mm thick | Mtr | 73.5 | 73.5 | 55.0 | False | None | None | False | None | False | 4042.5 | 0 | 2396708 | 71355 | None | code41 | Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.25 mm dia 2 mm thick | Mtr | 84.0 | 84.0 | 55.0 | False | None | None | False | None | False | 4620.0 | 0 | 2396709 | 71355 | None | code42 | Supplying and fixing PVC/metal conduit Deep junction box 25 mm deep Junction box | Each | 53.55 | 53.55 | 30.0 | False | None | None | False | None | False | 1606.5 | 0 | 2396710 | 71355 | None | code43 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, Finishing with necessary cement plastering complete.10" x 7" x 3" (254 x 178 x 76 mm) | Each | 106.05 | 106.05 | 4.0 | False | None | None | False | None | False | 424.2 | 0 | 2396711 | 71355 | None | code44 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, Finishing with necessary cement plastering complete.8" x 6" x 3" (203 x 152 x 76 mm) | Each | 78.75 | 78.75 | 4.0 | False | None | None | False | None | False | 315.0 | 0 | 2396712 | 71355 | None | code45 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, Finishing with necessary cement plastering complete.4" x 4" x 3" ( 101 x 101 x 76 mm | Each | 72.45 | 72.45 | 4.0 | False | None | None | False | None | False | 289.8 | 0 | 2396713 | 71355 | None | code46 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, Finishing with necessary cement plastering complete. 12" x 9" x 3" (300 x 228 x 76 mm) | Each | 110.25 | 110.25 | 3.0 | False | None | None | False | None | False | 330.75 | 0 | 2396714 | 71355 | None | code47 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP A Short point upto 3m from tapping point to out let via switch | Point | 289.8 | 289.8 | 6.0 | False | None | None | False | None | False | 1738.8 | 0 | 2396715 | 71355 | None | code48 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP A Medium point above 3m upto 6m from tapping point to out let via switch | Point | 405.3 | 405.3 | 6.0 | False | None | None | False | None | False | 2431.8 | 0 | 2396716 | 71355 | None | code49 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP A Long point above 6m upto 10m from tapping point to out let via switch | Point | 595.35 | 595.35 | 12.0 | False | None | None | False | None | False | 7144.2 | 0 | 2396717 | 71355 | None | code50 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of 3C X 1.5 mm2 | Mtr | 72.45 | 72.45 | 55.0 | False | None | None | False | None | False | 3984.75 | 0 | 2396718 | 71355 | None | code51 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of 4C x 1.5 mm2 | Mtr | 92.4 | 92.4 | 55.0 | False | None | None | False | None | False | 5082.0 | 0 | 2396719 | 71355 | None | code52 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of 6C x 1.5 mm2 | Mtr | 117.6 | 117.6 | 55.0 | False | None | None | False | None | False | 6468.0 | 0 | 2396720 | 71355 | None | code53 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of 8C x 1.5 mm2 | Mtr | 165.9 | 165.9 | 55.0 | False | None | None | False | None | False | 9124.5 | 0 | 2396721 | 71355 | None | code54 | Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 6A 3/5 Way | Each | 150.15 | 150.15 | 6.0 | False | None | None | False | None | False | 900.9 | 0 | 2396722 | 71355 | None | code55 | Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 6A 2 Way | Each | 127.05 | 127.05 | 6.0 | False | None | None | False | None | False | 762.3 | 0 | 2396723 | 71355 | None | code56 | Supplying and mounting 2 Nos. of 2Way 6 A flush type switches either surface/flush mounted on existing gang box or in 4mm thick plastic sheet and mounted on a flush mounted wooden box and wiring as per IS 1293 | Each | 170.1 | 170.1 | 6.0 | False | None | None | False | None | False | 1020.6 | 0 | 2396724 | 71355 | None | code57 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.1-3 Way | Each | 95.55 | 95.55 | 4.0 | False | None | None | False | None | False | 382.2 | 0 | 2396725 | 71355 | None | code58 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 6 Way | Each | 156.45 | 156.45 | 4.0 | False | None | None | False | None | False | 625.8 | 0 | 2396726 | 71355 | None | code59 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles.Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system.48" Sweep (1200 mm) Regular model | Each | 2189.25 | 2189.25 | 4.0 | False | None | None | False | None | False | 8757.0 | 0 | 2396727 | 71355 | None | code60 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts,nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure III - Double Door 6 Way TP & N | Each | 3921.75 | 3921.75 | 3.0 | False | None | None | False | None | False | 11765.25 | 0 | 2396728 | 71355 | None | code61 | Supplying and fixing of retrofit type - LED bulb ...... W withOPAL acrylic diffuser comprising of LED source with CCT 6500degree K, CRImore than 70%. efficacy more than80 lumen per W, lifemore than 25000burning hours and Compliance to IS 10322/IEC 60598, LM 79and LM 80. The LED are driven by HF electronic driver integratedin the system, with PF more than 0.95, power loss should less than 5% of lampWage., short circuit and open circuit protection to be integratedin the circuit, THD less than 20%, Life as per LM 79. Theoperating input voltage should be between 130 to 275 V. BISApproved and Tested by NABL/CPRI accredited laboratorywith 2 years Warranty against any manufacturing defect working under standard electrical condition.(Elec SR -2022-23) P.No.38 ITEM NO. 11.11.7( 18W Bulb) | Each | 457.8 | 457.8 | 10.0 | False | None | None | False | None | False | 4578.0 | 0 |
|
|
---|