createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1706873365502
version3
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeONE_COVER
evaluationTypeTextOne Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee700.00
emd55640.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose17-02-2024 17:00:00
tenderQueryClose16-02-2024 17:00:00
technicalBidOpenNone
publishedDate02-02-2024 17:16:03
publishedByPostRDPR_EE_DIV_VJN
publishedByUserKPE12111 - J R PAMPAPATHI
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonEE OFFICE
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber9482100616
tenderSupplierListNone
tenderSchedule
createdTs1706873365542
version8
createdDateNone
modifiedDateNone
tenderNumberRDPR/2023-24/BD/WORK_INDENT4095
titleConstruction Of Two Class room At GHPS School MP Prakash Nagara In Town Hosapete taluk.
descriptionConstruction Of Two Class room At GHPS School MP Prakash Nagara In Town Hosapete taluk.
categoryWORKS
categoryTextWorks
ecv2776349.37
deptNameRural Development and Panchayat Raj Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location943
locationNameRDPR Division Office Vijayanagara
provisionalAmount2782000.0
groupOverheadTotal423510.92
fileNumberPRED/SUB/AE/KKRDBMICROGRANTS/2023-24
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17068733660000NoneNoneBuildingsConstruction Of Two Class room At GHPS School MP Prakash Nagara In Town Hosapete taluk.2352838.45
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
240771371895Nonecode01Construction Of Two Class room At GHPS Shool MP Prakash Nagara In Town Hosapete taluk.Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead. By Mechanical Means Prestressed / Reinforced cement concrete grade M-20 & aboveCum1163.41163.421.57FalseNoneNoneFalseNoneFalse25094.5380
240771471895Nonecode02Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead. By Manual Means Dismantling Brick / Tile workCum640.5640.540.54FalseNoneNoneFalseNoneFalse25965.870
240771571895Nonecode03Earth work excavation for FOUNDATION by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work Depth exceeding 1.5 m, but not exceeding 3 mCum654.15654.1566.26FalseNoneNoneFalseNoneFalse43343.9790
240771671895Nonecode04Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/ trap / basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregatesCum6123.66123.620.92FalseNoneNoneFalseNoneFalse128105.7120
240771771895Nonecode05Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6941.246941.2411.82FalseNoneNoneFalseNoneFalse82045.45680
240771871895Nonecode06Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand)Cum5891.555891.5528.12FalseNoneNoneFalseNoneFalse165670.3860
240771971895Nonecode07Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6708.456708.4521.44FalseNoneNoneFalseNoneFalse143829.1680
240772071895Nonecode08Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum214.2214.2121.87FalseNoneNoneFalseNoneFalse26104.5540
240772171895Nonecode09Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Cum12323.6412323.6410.99FalseNoneNoneFalseNoneFalse135436.80360
240772271895Nonecode10Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum11598.7211598.7225.81FalseNoneNoneFalseNoneFalse299362.96320
240772371895Nonecode11Providing Brick work with common burnt clay machine moulded perforated bricks of class designation 5.0 conforming to IS: 2222 in superstructure above plinth level in cement mortar 1:6 (1 cement : 6 coarse sand) With Non modular bricks including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum8621.558621.5523.98FalseNoneNoneFalseNoneFalse206744.7690
240772471895Nonecode12Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum10095.710095.70.47FalseNoneNoneFalseNoneFalse4744.9790
240772571895Nonecode13Supplying, Fitting and Placing TMT Fe 500 & above Reinforcement in Foundation/Substructure/Superstructure complete as per Drawing and Technical Specifications.Tonne93929.8593929.854.79FalseNoneNoneFalseNoneFalse449923.98150
240772671895Nonecode14Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specificationsSqm144977.7144977.70.14FalseNoneNoneFalseNoneFalse20296.8780
240772771895Nonecode15Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures )Sqm7816.27816.25.04FalseNoneNoneFalseNoneFalse39393.6480
240772871895Nonecode16Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC Matching to RAL9016 sections and with minimum TiO2Titanium Dioxide) at 6PHR with TPEThermo Plastic Elastomer) and lead free, gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile through out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wallthickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made).EtcSqm7070.77070.78.64FalseNoneNoneFalseNoneFalse61090.8480
240772971895Nonecode17Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kgs136.5136.5178.5FalseNoneNoneFalseNoneFalse24365.250
240773071895Nonecode18Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm334.69334.69151.32FalseNoneNoneFalseNoneFalse50645.29080
240773171895Nonecode19Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm423.94423.94159.78FalseNoneNoneFalseNoneFalse67737.13320
240773271895Nonecode20Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mmSqm1202.251202.25135.36FalseNoneNoneFalseNoneFalse162736.560
240773371895Nonecode21Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm172.62172.62314.16FalseNoneNoneFalseNoneFalse54230.29920
240773471895Nonecode22Finishing walls with textured exterior paint of required shade : New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm356.58356.58259.28FalseNoneNoneFalseNoneFalse92454.06240
240773571895Nonecode23Lettering with black Japan paint of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.cm4.24.21200.0FalseNoneNoneFalseNoneFalse5040.00
240773671895Nonecode24Concealed Conduit System : Supplying 19/20 mm dia 2 mm 2.5 mm thick heavy gauge PVC conduit pipe with suitable size bends metal / PC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18 SWG GI fish wire wherever necessary.Mtr66.066.055.0FalseNoneNoneFalseNoneFalse3630.00
240773771895Nonecode25Point wiring using copper wire with switch Supplying and wiring adopting loop system in existing PVC Conduit /casing caping using copper PVC insulated multi strand 2x1.5Sqmm copper wire with a 6Amps flush type SP control switch shall be fixed on the exisiting plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete for each outlet.Point wiring using class A Materials: for Short point upto 3Mtr from tapping point to out let via switch Item No. 2.1, Page No.5.and as per directed by Engineer Incharge of Work.a. Long point from 6mtr to 10 Mtr from tapping to via switchPoint394.0394.05.0FalseNoneNoneFalseNoneFalse1970.00
240773871895Nonecode26Wiring for lighting/power circuit using one of PVC insulated 1100v grade multis and Copper conductor single core cable in open or consealed system of wiring as per IS-694:1990 & confirming to GTP of Group-B . Group B Materials and as per directed by Engineer Incharge of Work.c.6 SqmmMtr117.0117.055.0FalseNoneNoneFalseNoneFalse6435.00
240773971895Nonecode27Supplying Patti type Flourcent tube light fitting of 2' suitable for 14 watts flour cent tube fitting made out of M.S. Sheet and stove enameled with loss open construction copper wound ferromagnetic ballast starter locking type brass contract holders moulded on double fold type sheet base fully wired to use on 230 volts AC supply including T5 lamp. Item No.4.5, Page no.20.and as per directed by Engineer Incharge of Work.Each1269.01269.08.0FalseNoneNoneFalseNoneFalse10152.00
240774071895Nonecode28Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating andI S: 374/79 and alsocomply with IS: 1709/1984 with latest amendment Rated voltage220V/50 Hz, Rated power input 48W+/-10%,Rated current As per IS:374/79, Rated power factor 0.9l agging (min), Rated speed 350+/-10%RPM, Rated airdelivery 210+/-10% Cubic Meter Minimum, Rated service value 4.2 CMM /W,Three Blade sofblade leaf 1.05mm thick Aluminium Alloy sheet, Class B motor insulation ,210Micro Amp, Power input,W&current, Air Delivery & Fan Speed asperIS:374/1979 with latest amendment, 2year manufacturerWarranty.Each2677.02677.04.0FalseNoneNoneFalseNoneFalse10708.00
240774171895Nonecode29Supplying and fixing PVC / metal conduit accessories Deep type junction box a) 19/20 mm dia 2 mm thickEach49.049.06.0FalseNoneNoneFalseNoneFalse294.00
240774271895Nonecode30Supplying and flush mounting teak wooden box without front plank, made of not less than 12 mm thick wood, after due groove cutting, necessary masonry patch work complete a) 12"x12x3" (300x300x76 mm)Each120.0120.06.0FalseNoneNoneFalseNoneFalse720.00
240774371895Nonecode31Point wiring using copper wire with switch Supplying and wiring adopting loop system in existing PVC conduit / casing caping using copper PVC insulated multi strand 2x1 5 sqmm copper wire with a 6 Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shaft be terminated with sufficient boose length in a wood / PVC round block complete for each outlet. a) Shoft point upto 3 Mtr from tapping point to outlet via switchEach285.0285.05.0FalseNoneNoneFalseNoneFalse1425.00
240774471895Nonecode32Point wiring using copper wire with switch Supplying and wiring adopting loop system in existing PVC conduit / casing caping using copper PVC insulated multi strand 2x1 5 sqmm copper wire with a 6 Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shaft be terminated with sufficient boose length in a wood / PVC round block complete for each outlet. b) Medium point upto 3 Mtr from tapping point to outlet via switchEach379.0379.05.0FalseNoneNoneFalseNoneFalse1895.00
240774571895Nonecode33Supplying and fixing of modular switch / socket / stepped electronic fan regulator dimmer / telephone socket etc on existing modular switch plate.a) 6 Amps one wayEach102.0102.010.0FalseNoneNoneFalseNoneFalse1020.00
240774671895Nonecode34Supplying and fixing 3 mm thick hylum plastic sheet etc complete with necessary nitches and screws etc complete.cm0.410.41552.0FalseNoneNoneFalseNoneFalse226.320
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17068733670000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17068733670000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17068733670000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17068733670000NoneNoneELIGIBILITYMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)None
17068733670000NoneNoneELIGIBILITYSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)None
17068733670000NoneNoneELIGIBILITYTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNone
17068733670000NoneNoneELIGIBILITYTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNone
17068733670000NoneNoneELIGIBILITYTotal value of civl engineering works executed and payments received in the last five years (year-wise)None
17068733670000NoneNoneELIGIBILITYList of existing commitments and ongoing worksNone
17068733670000NoneNoneELIGIBILITYList of works for which tenders already submittedNone
17068733670000NoneNoneELIGIBILITYBanker Details for referenceNone
17068733670000NoneNoneELIGIBILITYConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNone
17068733670000NoneNoneELIGIBILITYReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNone
17068733670000NoneNoneELIGIBILITYQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNone
17068733670000NoneNoneELIGIBILITYProposals for subcontracting components of works amounting to more than 20% of the contract price (for each, the qualifications and experience of the identified sub-contractor in the relevant fields should be attached)None
17068733830000NoneNoneELIGIBILITYThe Employer reserves the right to reject any or all Tenders without assigning any reasonNone
17068733910000NoneNoneELIGIBILITYCorrigendum modifications correction, if any, will be published in the website onlyNone
17068733970000NoneNoneELIGIBILITYDefect liability period will be one yearNone
17068734040000NoneNoneELIGIBILITYTo qualify for award of this contract, each Tenderer in his name should have in the last five years i.e 2018-19 to 2022-23 a. Achieved in at least two financial years a minimum financial turnover in all classes of civil engineering construction works only of Amount Put Tender (Turn over With compulsory UDIN Number)None
17068734130000NoneNoneELIGIBILITYTo qualify for award of this contract, each Tenderer in his name should have in the last five years i.e 2018-19 to 2022-23 b. Satisfactorily completed, as prime contractor, at least one similar work of value not less than 50% of the amount put tender (Workdone with indent No)None
17068734210000NoneNoneELIGIBILITYIf the tenderer has quoted below the schedule-B amount the difference amount should be paid in the form of F.D.R or D.D (As per G.O) in the name of Executive Engineer, PRE Division, Vijayanagara Hosapete from Nationalized Bank only and Upload the scanned copy of the same in e-portal at the time of applying the tender The Same Scanned copy for Different work will be liable for RejectionNone
17068734280000NoneNoneELIGIBILITYAll other conditions and requirements has to be fulfilled as per the standard bid document and attached General conditionsNone
preQualCriterionListNone
technicalCriterionListNone
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Valid PWD Registration copyTrueTechnical Bid
Last 5 years Audit Report with UDIN NoTrueTechnical Bid
Similar Nature Work done certificate with eproc Indent NoTrueTechnical Bid
Ongoing commitments and other KW DocumentsTrueTechnical Bid
Difference Amount DD or FDR Scanned copyTrueTechnical Bid
tenderWorkLocationList
tenderSubEstimateNamedistrictNametaluqNameloksabhaContNameassemblyContNamelocationDescriptionlatitudeDegreeslatitudeMinuteslatitudeSecondslongitudeDegreeslongitudeMinuteslongitudeSeconds
BuildingsVijayanagaraHosapeteBellaryHOSPETHOSAPETE TOWNNoneNoneNoneNoneNoneNone
tenderAddressNone
tenderRecallDTONone