1706602901000 | 0 | None | None | Water supply/sewage lines | Providing 400 mm dia Di raising main from kesare STP to devanoor lake and construction of storage tank and commissioning of pumpsets at Kesare STP, Mysore | 38126508.97 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2337904 | 69107 | None | code01 | Cutting Asphalt /Concrete road surface using machine cutter for leakage pit with earth work excavation in all classifications of soil including all lead and lifts bailing out water with pumps including barricading, danger lighting etc., as per requirement and disposing of the excavated stuff as directed. After attending the leak, refilling the trench for 30 cm depth quarry dust above and around pipelines and balance with available earth in layers not exceeding 20 cms in depth, compacting Each deposited layer by ramming including watering and consolidation by mechanical means approved by Engineer Incharge. (Work to be carried out as per leak repair manual and the rate includes hire charges of dewatering Pump, tractor,Jeep with all kinds of Labour in a Complete manner). | Cum | 1214.85 | 1214.85 | 75.0 | False | None | None | False | None | False | 91113.75 | 0 | 2337905 | 69107 | None | code02 | Clearing and grubbing land including uprooting rank vegetable grass, bushes, shrubs, saplings and trees upto 300mm girth by manual means, in areas of light jungle, removal of stumps, disposal of unserviceable materials, stacking of serviceable materials from road boundary etc. including cost of labour charges, all lead and lifts, etc. complete as directed by the Engineer in charge. | Sqm | 8.4 | 8.4 | 750.0 | False | None | None | False | None | False | 6300.0 | 0 | 2337906 | 69107 | None | code03 | Earth work excavation for pipeline trenches in all kinds of soils by mechanical means above 600 mm trench width as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & boning rods at every 100 mm whevere necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata. 'All kinds of soils. Depth upto 1.50 m | Cum | 275.1 | 275.1 | 3834.56 | False | None | None | False | None | False | 1054887.456 | 0 | 2337907 | 69107 | None | code04 | Earth work excavation for pipeline trenches in all kinds of soils by mechanical means above 600 mm trench width as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & boning rods at every 100 mm whevere necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata.Ordinary/soft rock (without requiring blasting) Depth upto 1.50 m | Cum | 476.7 | 476.7 | 676.69 | False | None | None | False | None | False | 322578.123 | 0 | 2337908 | 69107 | None | code05 | Earth work excavation for pipeline trenches in all kinds of soils by mechanical means above 600 mm trench width as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & boning rods at every 100 mm whevere necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata.Hard rock (blasting prohibited) Depth upto 1.50 m | Cum | 1064.7 | 1064.7 | 225.56 | False | None | None | False | None | False | 240153.732 | 0 | 2337909 | 69107 | None | code06 | Providing bedding for the pipeline trenches in black cotton and rock reaches including watering and consolidation by punners etc. complete with all lead and lift with: Murrum/Gravel | Cum | 375.95 | 375.95 | 105.0 | False | None | None | False | None | False | 39474.75 | 0 | 2337910 | 69107 | None | code07 | Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications | Cum | 168.0 | 168.0 | 4511.25 | False | None | None | False | None | False | 757890.0 | 0 | 2337911 | 69107 | None | code08 | Construction of Granular Sub-Base of required grading as per design mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 For Grading -V Material | Cum | 2611.35 | 2611.35 | 111.0 | False | None | None | False | None | False | 289859.85 | 0 | 2337912 | 69107 | None | code09 | Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. | Cum | 2686.95 | 2686.95 | 111.0 | False | None | None | False | None | False | 298251.45 | 0 | 2337913 | 69107 | None | code10 | Prime Coat over WMM/WBM Providing and applying primer coat with SS1 grade Bitumen Emulsion on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.90 kg per m2 using mechanical means. | Sqm | 43.05 | 43.05 | 740.03 | False | None | None | False | None | False | 31858.2915 | 0 | 2337914 | 69107 | None | code11 | Bituminous Macadam Grading - II for traffic greaterthan20 MSA Providing and laying Bituminous Macadam with 40/60 TPH capacity hot mix plant using crushed aggregates of specified grading premixed with bituminous binder VG-40 @ 3.4% by weight of mix, transported to site, laid over a previously prepared surface with mechanical paver finisher to the required grade, level and alignment and rolled as per clauses 501.6 and 501.7 to achieve the desired compaction | Cum | 8284.5 | 8284.5 | 37.0 | False | None | None | False | None | False | 306526.5 | 0 | 2337915 | 69107 | None | code12 | Tack coat on Bituminous surface Providing and applying tack coat with RS1 Bituminous Emulsion using emulsion pressure distributor at the rate of 0.20 kg/m2 on the prepared bituminous surface cleaned with mechanical broom | Sqm | 12.6 | 12.6 | 740.03 | False | None | None | False | None | False | 9324.378 | 0 | 2337916 | 69107 | None | code13 | Providing and laying Semi Dense Bituminous Concrete with 40/60 TPH capacity hot mix plant batch type using crushed aggregates of specified grading premixed with bituminous binder VG-30 @ 5% by weight of mix and filler, transported to site, laid over a previously prepared surface with mechanical paver finisher to the required grade, level and alignment and rolled as per MoRTH V revision. | Cum | 10659.6 | 10659.6 | 18.5 | False | None | None | False | None | False | 197202.6 | 0 | 2337917 | 69107 | None | code14 | Bituminous Concrete Grading I for traffic greaterthan20 MSA Providing and laying Bituminous Concrete with 40/60 TPH capacity hot mix plant using crushed aggregates of specified grading, premixed with bituminous binder VG-40 @ 5.2 per cent of mix and filler, transporting the hot mix to work site, laying with mechanical paver finisher to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORTH specification clause No. 507 complete in all respects | Cum | 11552.1 | 11552.1 | 55.5 | False | None | None | False | None | False | 641141.55 | 0 | 2337918 | 69107 | None | code15 | Providing and laying Ductile Iron pipes of class K7 conforming to IS 8329:2000 with latest amendments, conveyiing to work site, rolling and lowering into trenches, laying true to line, level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations, cutting of pipes wherever necessary, jointing with DI specials (excluding cost of specials) and rubber gaskets, cleaning the socket and spigot end with soap solution, applying soft soap to the socket and spigot ends before insertion of rubber gaskets, jacking and fixing in perfect conditions etc. The cost to include soap solution, soft soap, waste etc. and giving necessary hydraulic test to the required pressure as per ISS with all lead and lifts and cost of all jointing materials. (The contractor will make his own arrangements for water for testing. Earth work excavation in trenches to be measured and paid for seperately) Note: In sewerage projects for internal cement mortal lining ( CML ) of DI pipes, if High Alumina Cement ( HAC ) as recommended in Annexure B clause 16.3 of IS8329:2000 is considered in place of Slag or Sulphate Resistance Cement ( SRC ), the cost of pipes may be increased by 5-6% from the prices listed. 400 mm dia DI PIPE | Mtr | 6274.8 | 6274.8 | 3000.0 | False | None | None | False | None | False | 18824400.0 | 0 | 2337919 | 69107 | None | code16 | Supplying and fixing DI Resilient seated soft sealing SLUICE VALVE of various dia.with body, bonnet of ductile iron (DI) conforming to IS-1865 and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100% leak proof with face dimensions as per BS 5163-89 / IS 14846-2000 / DN 3202 F4/F5. The stem sealing should be with toroidal sealing rings (minimum 2 "O" rings). Body and bonut should be coated with Electrostatically applied Epoxy Powder Coating with minium coating thickness of 250 micron both inside and out side. The rate is inclusive of cost of valve, T.P set, galvanized bolts & nuts and rubber insertions etc. but excluding earth work. PN 16. 80 mm | Each | 10912.7 | 10912.7 | 7.0 | False | None | None | False | None | False | 76388.9 | 0 | 2337920 | 69107 | None | code17 | Supplying and fixing DI Resilient seated soft sealing SLUICE VALVE of various dia.with body, bonnet of ductile iron (DI) conforming to IS-1865 and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100% leak proof with face dimensions as per BS 5163-89 / IS 14846-2000 / DN 3202 F4/F5. The stem sealing should be with toroidal sealing rings (minimum 2 "O" rings). Body and bonut should be coated with Electrostatically applied Epoxy Powder Coating with minium coating thickness of 250 micron both inside and out side. The rate is inclusive of cost of valve, T.P set, galvanized bolts & nuts and rubber insertions etc. but excluding earth work. PN 16. 200 mm (Sluice for Scour) | Each | 34687.8 | 34687.8 | 3.0 | False | None | None | False | None | False | 104063.4 | 0 | 2337921 | 69107 | None | code18 | Supplying and fixing DI Resilient seated soft sealing SLUICE VALVE of various dia.with body, bonnet of ductile iron (DI) conforming to IS-1865 and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100% leak proof with face dimensions as per BS 5163-89 / IS 14846-2000 / DN 3202 F4/F5. The stem sealing should be with toroidal sealing rings (minimum 2 "O" rings). Body and bonut should be coated with Electrostatically applied Epoxy Powder Coating with minium coating thickness of 250 micron both inside and out side. The rate is inclusive of cost of valve, T.P set, galvanized bolts & nuts and rubber insertions etc. but excluding earth work. PN 16. 400 mm (Sluice for Scour | Each | 175321.6 | 175321.6 | 2.0 | False | None | None | False | None | False | 350643.2 | 0 | 2337922 | 69107 | None | code19 | Providing and fixing of Single/ Double chamber triple function tamper proof (Both the orifces to be housed in the single chamber) Air valves with Body and cover in Ductile cast iron of grade GGG 40/ 50. All internal parts such as float, shell with appurtenances., all cover bolts of austenitic alloy / SS 304 steel, DN 50 float of HOSTAFLON / SS 304 and gaskers and seals of EPDM. Epoxy powder coating (EP-P) inside and outside colour blue RAL5005. The valves should be designed for all the three functions i.e., 1. Large orifice for venting of large air volumes on start up. 2. Large orifice for intake of large air volumes. 3. Small orifice for discharge of pressurized air during operation. PN 16. 80 mm dia | Each | 30455.25 | 30455.25 | 7.0 | False | None | None | False | None | False | 213186.75 | 0 | 2337923 | 69107 | None | code20 | Supplying and fixing of DI specials with ISI mark confoming to IS 9523 / 2000 suitable for jointing 100 mm to 600 mm dia DI pipes coated with rust prevention coatings. A) External coating: a) Metalic zinc with finishing layer of bituminous as per Annexure “A”
of IS:9523/2000
b) Zinc rich paint with finishing layer of bituminous as per Annexure “A”of IS:9523 / 2000
c) Bituminous paint as per Annexure “C” of IS:9523 / 2000
B) Internal Lining:a) Portaland Cement (with or without additives) mortar as per Annexure - “B” of IS:9523/2000
b) Cement Mortar with coat coat as per Annexure “B” of IS:9523 / 2000
c) Bituminous paint as per Annexure “C” of IS:9523 / 2000 For bends, test gaps, Tees. Reducers for 400mm dia pipe for linking the inlet and out let | Kgs | 197.4 | 197.4 | 5000.0 | False | None | None | False | None | False | 987000.0 | 0 | 2337924 | 69107 | None | code21 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Valve chambers In all kinds of soils Depth upto 1.5 m (1.20 x 1.20 x 1.50)M | Cum | 254.1 | 254.1 | 27.88 | False | None | None | False | None | False | 7084.308 | 0 | 2337925 | 69107 | None | code22 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Valve chambers Depth exceeding 1.5m, but not exceeding 3 m (1.20 x 1.20 x 1.50)M | Cum | 271.95 | 271.95 | 7.11 | False | None | None | False | None | False | 1933.5645 | 0 | 2337926 | 69107 | None | code23 | Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical pecifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools,usage & other appurtenances required to complete the work.In ordinary/soft rock without blasting upto 1.5 m depth (1.20 x 1.20 x 1.50)M | Cum | 313.95 | 313.95 | 4.92 | False | None | None | False | None | False | 1544.634 | 0 | 2337927 | 69107 | None | code24 | Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical pecifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools,usage & other appurtenances required to complete the work.In ordinary/soft rock without blasting for Depth exceeding 1.5m, but not exceeding 3 m (1.20 x 1.20 x 1.50)M | Cum | 467.25 | 467.25 | 4.743 | False | None | None | False | None | False | 2216.16675 | 0 | 2337928 | 69107 | None | code25 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, form work, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates for PCC | Cum | 6288.45 | 6288.45 | 3.791 | False | None | None | False | None | False | 23839.51395 | 0 | 2337929 | 69107 | None | code26 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing, form work, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - for footing (Consider 3% as form work charges for other type of foundation) Raft | Cum | 6652.8 | 6652.8 | 2.688 | False | None | None | False | None | False | 17882.7264 | 0 | 2337930 | 69107 | None | code27 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, form work, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Consider 35% as form work charges for Concrete walls) Side wall | Cum | 9185.4 | 9185.4 | 14.448 | False | None | None | False | None | False | 132710.6592 | 0 | 2337931 | 69107 | None | code28 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) | MT | 82961.55 | 82961.55 | 1.371 | False | None | None | False | None | False | 113740.28505 | 0 | 2337932 | 69107 | None | code29 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Side wall | Sqm | 253.05 | 253.05 | 86.24 | False | None | None | False | None | False | 21823.032 | 0 | 2337933 | 69107 | None | code30 | Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications For Valve chamber size (1.20X1.20X1.50)m | Cum | 168.0 | 168.0 | 44.26 | False | None | None | False | None | False | 7435.68 | 0 | 2337934 | 69107 | None | code31 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work In all kinds of soils Depth upto 1.5 m (1.50X1.50X1.50)m | Cum | 254.1 | 254.1 | 15.938 | False | None | None | False | None | False | 4049.8458 | 0 | 2337935 | 69107 | None | code32 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work Depth exceeding 1.5m, but not exceeding 3 m(1.50X1.50X1.50)m | Cum | 271.95 | 271.95 | 2.625 | False | None | None | False | None | False | 713.86875 | 0 | 2337936 | 69107 | None | code33 | Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical pecifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools,usage & other appurtenances required to complete the work.In ordinary/soft rock without blasting upto 1.5 m depth | Cum | 313.95 | 313.95 | 1.935 | False | None | None | False | None | False | 607.49325 | 0 | 2337937 | 69107 | None | code34 | Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical pecifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools,usage & other appurtenances required to complete the work. In ordinary/soft rock without blasting for Depth exceeding 1.5m, but not exceeding 3 m | Cum | 467.25 | 467.25 | 1.75 | False | None | None | False | None | False | 817.6875 | 0 | 2337938 | 69107 | None | code35 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, form work, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates for PCC | Cum | 6288.45 | 6288.45 | 1.452 | False | None | None | False | None | False | 9130.8294 | 0 | 2337939 | 69107 | None | code36 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing, form work, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - for footing (Consider 3% as form work charges for other type of foundation) Raft | Cum | 6652.8 | 6652.8 | 1.083 | False | None | None | False | None | False | 7204.9824 | 0 | 2337940 | 69107 | None | code37 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, form work, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Consider 35% as form work charges for Concrete walls) Side wall & Covering slab | Cum | 9185.4 | 9185.4 | 5.163 | False | None | None | False | None | False | 47424.2202 | 0 | 2337941 | 69107 | None | code38 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) | MT | 82961.55 | 82961.55 | 0.5 | False | None | None | False | None | False | 41480.775 | 0 | 2337942 | 69107 | None | code39 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Side wall & cover slab | Sqm | 253.05 | 253.05 | 32.44 | False | None | None | False | None | False | 8208.942 | 0 | 2337943 | 69107 | None | code40 | Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications | Cum | 168.0 | 168.0 | 17.28 | False | None | None | False | None | False | 2903.04 | 0 | 2337944 | 69107 | None | code41 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technicalspecifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in aradius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m | Cum | 254.1 | 254.1 | 9.72 | False | None | None | False | None | False | 2469.852 | 0 | 2337945 | 69107 | None | code42 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technicalspecifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in aradius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depth | Cum | 271.95 | 271.95 | 6.48 | False | None | None | False | None | False | 1762.236 | 0 | 2337946 | 69107 | None | code43 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The ranite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)complete for Anchor Blocks/Thrust Blocks. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Consider 3% as form work charges for other type of foundation) | Cum | 6639.15 | 6639.15 | 17.28 | False | None | None | False | None | False | 114724.512 | 0 | 2337947 | 69107 | None | code44 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) | MT | 82961.55 | 82961.55 | 1.38 | False | None | None | False | None | False | 114486.939 | 0 | 2337948 | 69107 | None | code45 | Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications | Cum | 168.0 | 168.0 | 9.72 | False | None | None | False | None | False | 1632.96 | 0 | 2337949 | 69107 | None | code46 | Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead By Mechanical Means Cement Concrete Grade M-15 & M-20 | Cum | 754.95 | 754.95 | 2.25 | False | None | None | False | None | False | 1698.6375 | 0 | 2337950 | 69107 | None | code47 | Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead By Mechanical Means Dismantling Brick / Tile work / rubble masonry / pitching / etc by mechanical means | Cum | 189.0 | 189.0 | 7.2 | False | None | None | False | None | False | 1360.8 | 0 | 2337951 | 69107 | None | code48 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates PCC | Cum | 6288.45 | 6288.45 | 2.25 | False | None | None | False | None | False | 14149.0125 | 0 | 2337952 | 69107 | None | code49 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6708.45 | 6708.45 | 7.2 | False | None | None | False | None | False | 48300.84 | 0 | 2337953 | 69107 | None | code50 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Foundation, (Consider 5% as form work charges for Sub structure of Cross drainages) Deck Slab | Cum | 6601.35 | 6601.35 | 2.25 | False | None | None | False | None | False | 14853.0375 | 0 | 2337954 | 69107 | None | code51 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) | MT | 82961.55 | 82961.55 | 0.18 | False | None | None | False | None | False | 14933.079 | 0 | 2337955 | 69107 | None | code52 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.In all kinds of soils Depth upto 1.5 m | Cum | 254.1 | 254.1 | 12.68 | False | None | None | False | None | False | 3221.988 | 0 | 2337956 | 69107 | None | code53 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.In ordinary/soft rock without blasting upto 1.5 m depth | Cum | 313.95 | 313.95 | 12.68 | False | None | None | False | None | False | 3980.886 | 0 | 2337957 | 69107 | None | code54 | Providing and Filling in foundation with granite / trap broken metal 100mm and down size with approved M-Sand including hand packing, ramming, watering including cost of all materials and labour with all lead and lift complete as per specifications | Cum | 2816.1 | 2816.1 | 5.0 | False | None | None | False | None | False | 14080.5 | 0 | 2337958 | 69107 | None | code55 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse
aggregates 1 x 1.0 x 1.0 x0.15 | Cum | 6602.87 | 6602.87 | 1.5 | False | None | None | False | None | False | 9904.305 | 0 | 2337959 | 69107 | None | code56 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing, form work, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - for footing (Consider 3% as form work charges for other type of foundation | Cum | 6652.8 | 6652.8 | 7.0 | False | None | None | False | None | False | 46569.6 | 0 | 2337960 | 69107 | None | code57 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately | MT | 82961.55 | 82961.55 | 0.7 | False | None | None | False | None | False | 58073.085 | 0 | 2337961 | 69107 | None | code58 | Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications | Cum | 168.0 | 168.0 | 25.35 | False | None | None | False | None | False | 4258.8 | 0 | 2337962 | 69107 | None | code59 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m | Cum | 107.1 | 107.1 | 64.54 | False | None | None | False | None | False | 6912.234 | 0 | 2337963 | 69107 | None | code60 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth | Cum | 381.15 | 381.15 | 38.52 | False | None | None | False | None | False | 14681.898 | 0 | 2337964 | 69107 | None | code61 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work Depth exceeding 1.5 m, but not exceeding 3 m | Cum | 446.25 | 446.25 | 26.37 | False | None | None | False | None | False | 11767.6125 | 0 | 2337965 | 69107 | None | code62 | Earth work excavation for FOUNDATION by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work In Hard Rock ( requiring blasting) Depth upto 1.50m | Cum | 581.7 | 581.7 | 38.52 | False | None | None | False | None | False | 22407.084 | 0 | 2337966 | 69107 | None | code63 | Earth work excavation for FOUNDATION by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work Depth exceeding 1.5 m, but not exceeding 3 m | Cum | 654.15 | 654.15 | 26.37 | False | None | None | False | None | False | 17249.9355 | 0 | 2337967 | 69107 | None | code64 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6527.85 | 6527.85 | 41.54 | False | None | None | False | None | False | 271166.889 | 0 | 2337968 | 69107 | None | code65 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6708.45 | 6708.45 | 18.58 | False | None | None | False | None | False | 124643.001 | 0 | 2337969 | 69107 | None | code66 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Add 70% for columns and 50% rate for Form works) Column footing , Column upto GL pedestal, Above GL, Pump pit raft , Pump pit sides | Cum | 11310.76 | 11310.76 | 55.56 | False | None | None | False | None | False | 628425.8256 | 0 | 2337970 | 69107 | None | code67 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Add 70% for columns and 50% rate for Form works)plinth Beams above G.L, Lintel, roof beam, Corbel beam ,Corbel , roof slab,Chejja main dooor , Windows Chejja | Cum | 9979.2 | 9979.2 | 32.55 | False | None | None | False | None | False | 324822.96 | 0 | 2337971 | 69107 | None | code68 | Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 9317.7 | 9317.7 | 25.19 | False | None | None | False | None | False | 234712.863 | 0 | 2337972 | 69107 | None | code69 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 2764.65 | 2764.65 | 9.0 | False | None | None | False | None | False | 24881.85 | 0 | 2337973 | 69107 | None | code70 | Providing and fixing ball bearing for rolling shutters including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Nos | 423.15 | 423.15 | 1.0 | False | None | None | False | None | False | 423.15 | 0 | 2337974 | 69107 | None | code71 | Extra for providing Manually operated Bevel Gear Box for operating rolling shutters including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Nos | 3240.3 | 3240.3 | 1.0 | False | None | None | False | None | False | 3240.3 | 0 | 2337975 | 69107 | None | code72 | Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6 PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets -grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame.The outer frame having an overall size of 44mm width x 40mmheight with reinforcement of 1mm thickness and Sash with overall size of 27mm X 53mm with UPVC honeycomb structure inside in lieu of GI reinforcement. Coextruded Glazing bead for fixing of glass shall be of size 9.5mm x 21.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with Crescent Locks. Wall thickness of frame & sash shall be of 2 mm.Maximum possible size 1219mm x 1219mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) | Sqm | 5274.15 | 5274.15 | 29.25 | False | None | None | False | None | False | 154268.8875 | 0 | 2337976 | 69107 | None | code73 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. | Sqm | 192.15 | 192.15 | 490.0 | False | None | None | False | None | False | 94153.5 | 0 | 2337977 | 69107 | None | code74 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 267.75 | 267.75 | 273.75 | False | None | None | False | None | False | 73296.5625 | 0 | 2337978 | 69107 | None | code75 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 309.75 | 309.75 | 315.35 | False | None | None | False | None | False | 97679.6625 | 0 | 2337979 | 69107 | None | code76 | Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge. basement | Sqm | 267.75 | 267.75 | 17.91 | False | None | None | False | None | False | 4795.4025 | 0 | 2337980 | 69107 | None | code77 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 55.65 | 55.65 | 315.35 | False | None | None | False | None | False | 17549.2275 | 0 | 2337981 | 69107 | None | code78 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 93.45 | 93.45 | 425.75 | False | None | None | False | None | False | 39786.3375 | 0 | 2337982 | 69107 | None | code79 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 133.35 | 133.35 | 273.75 | False | None | None | False | None | False | 36504.5625 | 0 | 2337983 | 69107 | None | code80 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 175.35 | 175.35 | 18.0 | False | None | None | False | None | False | 3156.3 | 0 | 2337984 | 69107 | None | code81 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latestamendments and conveying to worksite, rolling and lowering intotrenches, laying true to line and level and perfect linking at joints, testingand commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make
his own arrangements for procuring water for testing) etc. for: | Mtr | 308.7 | 308.7 | 16.0 | False | None | None | False | None | False | 4939.2 | 0 | 2337985 | 69107 | None | code82 | Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per direction of Engineer incharge. | Sqm | 840.0 | 840.0 | 84.0 | False | None | None | False | None | False | 70560.0 | 0 | 2337986 | 69107 | None | code83 | Providing Thermo-Mechanically Treated bars of grade Fe-550D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) | Kg | 93929.85 | 93929.85 | 9.2524 | False | None | None | False | None | False | 869076.54414 | 0 | 2337987 | 69107 | None | code84 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. | Sqm | 857.85 | 857.85 | 108.24 | False | None | None | False | None | False | 92853.684 | 0 | 2337988 | 69107 | None | code85 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 279.3 | 279.3 | 218.61 | False | None | None | False | None | False | 61057.773 | 0 | 2337989 | 69107 | None | code86 | SupplyingheavygaugePVCconduitpipe......mmdia..........mmthickconfirmingtoIS2509withsuitablesizebends,metal/PVCJunctionboxes,adhesivepasteetc.,andrunningbeforeconcretingtheslab.TheconduitshouldbetiedtothereinforcementrodsbyusingbindingwiresandunusedwaysofjunctionboxesandpipeendsshouldbecoveredusingPVCendenclosures,runwith18SWGGIfishwire wherever necessary | Mtr | 78.0 | 78.0 | 150.0 | False | None | None | False | None | False | 11700.0 | 0 | 2337990 | 69107 | None | code87 | SupplyingheavygaugePVCConduitPipe....dia.......mmthickwithsuitablesizebends,metaljunctionboxesadhesivepasteetc.,bygroovecuttinginthewallandfixingbybracingUorJhooksandcementplasteringuptothewallsurfaceandrunwith18SWGGIfish wire run throughout the conduit wherever necessary. | Mtr | 79.0 | 79.0 | 150.0 | False | None | None | False | None | False | 11850.0 | 0 | 2337991 | 69107 | None | code88 | Supplying and fixing PVC/metal conduit Deep junction box 19/20 mm deep Junction box | Each | 61.0 | 61.0 | 40.0 | False | None | None | False | None | False | 2440.0 | 0 | 2337992 | 69107 | None | code89 | Supplyingandflushmountingpowdercoated/galvanizedmetalboxsuitableformountingmodularswitchplates.Theboxshouldbefirmly Flush mounted after due groove cutting in Brick/Stone/C.C wall 1- 3 Way | Each | 159.0 | 159.0 | 10.0 | False | None | None | False | None | False | 1590.0 | 0 | 2337993 | 69107 | None | code90 | Supplyingandfixingsuperiorqualitymodularswitchmountingpolycarbonateplatewithnecessarysupportingbackplatewithrequirednos.ofmachinescrews,boltsnutsetc.,completeontheexisting metal/PVC box. 6 Module | Each | 234.0 | 234.0 | 10.0 | False | None | None | False | None | False | 2340.0 | 0 | 2337994 | 69107 | None | code91 | Supplyingandfixingsuperiorqualitymodularswitchmountingpolycarbonateplatewithnecessarysupportingbackplatewithrequirednos.ofmachinescrews,boltsnutsetc.,completeonthe existing metal/PVC box. | Each | 161.0 | 161.0 | 10.0 | False | None | None | False | None | False | 1610.0 | 0 | 2337995 | 69107 | None | code92 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8Moudule | Each | 284.0 | 284.0 | 20.0 | False | None | None | False | None | False | 5680.0 | 0 | 2337996 | 69107 | None | code93 | Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate.. Is 3854 and IS 1293. Using Group "A" materials 6Amps one way. | Each | 88.0 | 88.0 | 20.0 | False | None | None | False | None | False | 1760.0 | 0 | 2337997 | 69107 | None | code94 | Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate.. Is 3854 and IS 1293. Using Group "A" materials 6Amps Two way. | Each | 152.0 | 152.0 | 20.0 | False | None | None | False | None | False | 3040.0 | 0 | 2337998 | 69107 | None | code95 | Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate.. Is 3854 and IS 1293. Using Group "A" materials 6Amps 3way socket. | Each | 147.0 | 147.0 | 5.0 | False | None | None | False | None | False | 735.0 | 0 | 2337999 | 69107 | None | code96 | Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate.. Is 3854 and IS 1293. Using Group "A" materials Stepped Fan Regulator. | Each | 357.0 | 357.0 | 4.0 | False | None | None | False | None | False | 1428.0 | 0 | 2338000 | 69107 | None | code97 | Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate.. Is 3854 and IS 1293. Using Group "A" materials 32Amps DP switch | Each | 326.0 | 326.0 | 10.0 | False | None | None | False | None | False | 3260.0 | 0 | 2338001 | 69107 | None | code98 | Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate.. Is 3854 and IS 1293. 6/16Amps universal socket | Each | 236.0 | 236.0 | 10.0 | False | None | None | False | None | False | 2360.0 | 0 | 2338002 | 69107 | None | code99 | Supplying PVC/Gi Flexible conduit pipe.. Mm dia fxing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddies at an interval of 300mm using NF screws on the either end of the pipe terminated completely. 25mm | Mtr | 81.0 | 81.0 | 50.0 | False | None | None | False | None | False | 4050.0 | 0 | 2338003 | 69107 | None | code100 | Supplyin and Fixing Metal Fan Box with Round Hook. | Nos | 117.0 | 117.0 | 4.0 | False | None | None | False | None | False | 468.0 | 0 | 2338004 | 69107 | None | code101 | Point wiring using Copper wire without switch.Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 1100V Grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2x1.5 Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose lenght in a wood/PVC round block. complete for each outlet. Short point up to 3Mtr from tapping point to out let via switch | Point | 285.0 | 285.0 | 20.0 | False | None | None | False | None | False | 5700.0 | 0 | 2338005 | 69107 | None | code102 | Point wiring using Copper wire without switch.Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 1100V Grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2x1.5 Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose lenght in a wood/PVC round block. complete for each outlet. Medium point above 3mtr up to 6Mtr from tapping point to out let via switch | Point | 394.0 | 394.0 | 24.0 | False | None | None | False | None | False | 9456.0 | 0 | 2338006 | 69107 | None | code103 | Point wiring using Copper wire without switch.Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 1100V Grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2x1.5 Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose lenght in a wood/PVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switch box | Point | 570.0 | 570.0 | 24.0 | False | None | None | False | None | False | 13680.0 | 0 | 2338007 | 69107 | None | code104 | Wiring for lighting/Power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper With Low conductor resistance single core wire in open or conceanled system of wiring with specified IS-694:1990 & confirming to the attached. (P-5/I-2.3.3) GTP of GROUP-a 2.5 sqmm | Mtr | 35.0 | 35.0 | 240.0 | False | None | None | False | None | False | 8400.0 | 0 | 2338008 | 69107 | None | code105 | Wiring for lighting/Power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper With Low conductor resistance single core wire in open or conceanled system of wiring with specified IS-694:1990 & confirming to the attached.4 sqmm | Mtr | 49.0 | 49.0 | 240.0 | False | None | None | False | None | False | 11760.0 | 0 | 2338009 | 69107 | None | code106 | Extra for supplying 4mm thick white plastic plate and covering for junction boxes of size ……mm conduit using necessary machine screws. 80mm | Mtr | 12.0 | 12.0 | 30.0 | False | None | None | False | None | False | 360.0 | 0 | 2338010 | 69107 | None | code107 | Supplying of ....... feet - LED PVC Square Batten ..W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greaterthan 80. Power Input: 220-240V @ 50Hz & Power factor greaterthan0.9 along with CE approved. 5 years Warranty against any manufacturing defect working under standard electrical condition LED light fighting 2'- 9/10 w | Each | 551.0 | 551.0 | 20.0 | False | None | None | False | None | False | 11020.0 | 0 | 2338011 | 69107 | None | code108 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies for operation on 230 Volts, 50 Cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm)Regular model | Each | 2984.0 | 2984.0 | 4.0 | False | None | None | False | None | False | 11936.0 | 0 | 2338012 | 69107 | None | code109 | Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete.12" Sweep (300mm) | Each | 2969.0 | 2969.0 | 4.0 | False | None | None | False | None | False | 11876.0 | 0 | 2338013 | 69107 | None | code110 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' cure, indicator ON/OFF, energy cross-3 with Short circuit breaking cappacity of 10K and complete wiring as required. Confirming to IEC 60898. 6-32 Amps DP | Each | 739.0 | 739.0 | 2.0 | False | None | None | False | None | False | 1478.0 | 0 | 2338014 | 69107 | None | code111 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' cure, indicator ON/OFF, energy cross-3 with Short circuit breaking cappacity of 10K and complete wiring as required. Confirming to IEC 60898. 50-63Amps TNP | Each | 1102.0 | 1102.0 | 2.0 | False | None | None | False | None | False | 2204.0 | 0 | 2338015 | 69107 | None | code112 | Supplying fxing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V upto 300mA sensitvity on existing wood/panel 32-40 Amps 4 pole | Each | 5147.0 | 5147.0 | 2.0 | False | None | None | False | None | False | 10294.0 | 0 | 2338016 | 69107 | None | code113 | Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm alround with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts. | Each | 4256.0 | 4256.0 | 2.0 | False | None | None | False | None | False | 8512.0 | 0 | 2338017 | 69107 | None | code114 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required.GI strip 25x3mm | Mtr | 82.0 | 82.0 | 8.0 | False | None | None | False | None | False | 656.0 | 0 | 2338018 | 69107 | None | code115 | Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with suitable approved colour powder coated paint.18SWG | Sq CM | 0.38 | 0.38 | 40000.0 | False | None | None | False | None | False | 15200.0 | 0 | 2338019 | 69107 | None | code116 | Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic alluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary botls,nuts and washers etc., complete.100Amps 4x30x6mm Alluminium Strips | Mtr | 2465.0 | 2465.0 | 1.0 | False | None | None | False | None | False | 2465.0 | 0 | 2338020 | 69107 | None | code117 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers.. 63Amps | Each | 372.0 | 372.0 | 4.0 | False | None | None | False | None | False | 1488.0 | 0 | 2338021 | 69107 | None | code118 | Supplying of 1.1 KV LT UG cable having aluminium conductor PVC insulated, extruded inner sheathed,galvanised,steel strip (except 2CX10Sq.mm wire armoured) confirming to IS-3975:1990 (No. of Strip indicated in GTP) & extruded PVC outer sheathed armoured cable with specified IS-1554 Part-1:1988 & confirming to the attached GTP of GROUP-A. 4 core 16 sqmm | Mtr | 371.0 | 371.0 | 25.0 | False | None | None | False | None | False | 9275.0 | 0 | 2338022 | 69107 | None | code119 | Providing and fixing Structural Steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing inposition and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kgs | 106.0 | 106.0 | 455.0 | False | None | None | False | None | False | 48230.0 | 0 | 2338023 | 69107 | None | code120 | Design, fabrication, supply, erection and commissioning of rail track using 45 kg / m standard rails for movement of gantry crane for handling tonners including cost of all materials, machinery, labour, aligning, anchoring, welding, cleaning, applying one coat of zinc rich epoxy primer and two coats of cold applied coal tar epoxy paint for buffers and rail supporting plates etc., complete as per specifications and approved drawings with all lead and all lifts including packing / forwarding charges for other materials. | Mtr | 8700.0 | 8700.0 | 17.0 | False | None | None | False | None | False | 147900.0 | 0 | 2338024 | 69107 | None | code121 | Providing, erecting triple spur gear type Chain Pulley Block suitable for capacity as below with 6 m lift complete with load chain and hand chain suitable for above lift, tested to 50% over load as per IS 3832 carrying ISI mark. -do- 3 Tonne Capacity. | Each | 23326.0 | 23326.0 | 1.0 | False | None | None | False | None | False | 23326.0 | 0 | 2338025 | 69107 | None | code122 | Providing, erecting Traveling Trolley of capacity as below with 6 m lift, tested to 50% over load. -do- 3 Tonne Capacity. | Each | 15652.0 | 15652.0 | 1.0 | False | None | None | False | None | False | 15652.0 | 0 | 2338026 | 69107 | None | code123 | Providing and constructing size stone pitching using 200 to 250 mm size stones with pin headers at 2 per m2 set in CM 1 : 5 proportion by volume with pointing joints in CM 1 : 3 proportion by volume including cost of all materials from approved source, labour, packing stone chips and mortar into joints,finishing,curing and all other ancillary operations complete. Note: If 150 mm thick murum bed is to be provided below pitching, add 93/ m2 | Sqm | 1157.1 | 1157.1 | 1125.0 | False | None | None | False | None | False | 1301737.5 | 0 | 2338027 | 69107 | None | code124 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. Depth upto 1.5m All kinds of soils. | Cum | 107.1 | 107.1 | 92.28 | False | None | None | False | None | False | 9883.188 | 0 | 2338028 | 69107 | None | code125 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In Ordinary rock witout blasting depth exceeding 1.5m but not exceeding 3m | Cum | 381.15 | 381.15 | 16.29 | False | None | None | False | None | False | 6208.9335 | 0 | 2338029 | 69107 | None | code126 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. Depth 1.5 m to 3m All kinds of soils | Cum | 107.1 | 107.1 | 95.98 | False | None | None | False | None | False | 10279.458 | 0 | 2338030 | 69107 | None | code127 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. Depth 1.5 m to 3m In Ordinary rock witout blasting depth exceeding 1.5m but not exceeding 3m | Cum | 446.25 | 446.25 | 51.68 | False | None | None | False | None | False | 23062.2 | 0 | 2338031 | 69107 | None | code128 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work.Depth 3 m to 4.5m All kinds of soils. | Mtr | 122.85 | 122.85 | 48.86 | False | None | None | False | None | False | 6002.451 | 0 | 2338032 | 69107 | None | code129 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work.In Ordinary rock witout blasting depth exceeding 3 m but not 4.5m | Mtr | 486.15 | 486.15 | 48.86 | False | None | None | False | None | False | 23753.289 | 0 | 2338033 | 69107 | None | code130 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6555.15 | 6555.15 | 8.92 | False | None | None | False | None | False | 58471.938 | 0 | 2338034 | 69107 | None | code131 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6808.04 | 6808.04 | 5.67 | False | None | None | False | None | False | 38601.5868 | 0 | 2338035 | 69107 | None | code132 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Mtr | 9362.59 | 9362.59 | 30.91 | False | None | None | False | None | False | 289397.6569 | 0 | 2338036 | 69107 | None | code133 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregate For roof slab | Cum | 10402.88 | 10402.88 | 5.67 | False | None | None | False | None | False | 58984.3296 | 0 | 2338037 | 69107 | None | code134 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregate For beam | Cum | 10402.88 | 10402.88 | 1.07 | False | None | None | False | None | False | 11131.0816 | 0 | 2338038 | 69107 | None | code135 | Providing and fixing MS inspection door of size 60 cms x 60 cms, including MS frame made of 50x50x6mm angle, shutters made of 3mm thick MS sheets, with hinges, locking arrangements at top etc. including painting with anticorrosive approved paint etc. complete including all lead and lifts etc | Each | 2247.0 | 2247.0 | 1.0 | False | None | None | False | None | False | 2247.0 | 0 | 2338039 | 69107 | None | code136 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.: Staging upto 6 m height | MT | 82961.55 | 82961.55 | 4.33 | False | None | None | False | None | False | 359223.5115 | 0 | 2338040 | 69107 | None | code137 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m | Cum | 279.3 | 279.3 | 353.95 | False | None | None | False | None | False | 98858.235 | 0 | 2338041 | 69107 | None | code138 | Supply, errection, electrification and commissioning of 2 Nos. of 150 HP Non clog submersible sewage pumpsetsfor pumping sewage SUITABLE HP NON-CLOG SEWAGE PUMPSETS, PUMPSETS: Supply and delivery at site brand new approved makes sludge submersible pump coupled to approved make squirrel cage induction motor of suitable HP 'F' class insulation for the specified discharge and head mentioned below. The pumpset should operate in full range of discharge and should have the following accessories specified in the following detailed specification. the submersible sewage pump shall be monoblock type with non-clong design.DISCHAGE Q = 750CUM/HR (208.33LPS) HEAD = 46M , PUMP CASING, IMPELLER,PUMP SHAFT, PUMP BEARING, GUIDE RAIL SYSTEM,Moistor sensor(seal moistor), MECHANICAL SEAL,LIFTING CHAIN, DUCK FOOT BEND, PROFILE GASKET (Dismantling joint), SUBMERSIBLE MOTOR CABLE, FASTENERS, 01 Nos of 150 HP OR Suitable HP 69.44 LPS against 46 Mtr. Head MOTOR: The submersible motor shall be dry, squirrel cage type suitable for 3 phase, 50 cycles, 415 volts AC supply,3000 Rpm complete confirming to ISS:325/1976 shall be of such capacity to provide under working site condition at power which is 10% more than the maximum power required by the pump. Continuous duty with class 'F' insulation. Winding of the motor shall be impregnated by resin. Motor shall have integral cable entry port better starting torque characteristics. The enclosure for motor shall be IP-68. Each phase of the motor provided with thermic switches of Bi-metalic electro-mechanical temperature detectors. The motor shall operate satisfactorily at all operating levels in wetwell. The motor shall be sealed against entry of liquid being pumped by using two mechanical seals. Motor pump should have the following in built protection connections. (Please refer the attachment for detailed Specifications) | Nos | 3015000.0 | 3015000.0 | 1.0 | False | None | None | False | None | False | 3015000.0 | 0 | 2338042 | 69107 | None | code139 | CONTROL SWITCH GEAR PANELS -CONTROL SWITCH GEAR PANELS (Total Run 2 nos 150 HP Has to Run) Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. ( Icu = Ics), 700-800 A 50 kA | Nos | 52395.0 | 52395.0 | 1.0 | False | None | None | False | None | False | 52395.0 | 0 | 2338043 | 69107 | None | code140 | Supplying and fixing of Shunt trip suitable for MCCB.CBCT | Nos | 1788.15 | 1788.15 | 1.0 | False | None | None | False | None | False | 1788.15 | 0 | 2338044 | 69107 | None | code141 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 Amps SP | Nos | 435.75 | 435.75 | 32.0 | False | None | None | False | None | False | 13944.0 | 0 | 2338045 | 69107 | None | code142 | Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board | Nos | 9717.75 | 9717.75 | 1.0 | False | None | None | False | None | False | 9717.75 | 0 | 2338046 | 69107 | None | code143 | Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy | Nos | 9780.75 | 9780.75 | 1.0 | False | None | None | False | None | False | 9780.75 | 0 | 2338047 | 69107 | None | code144 | Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound | Nos | 590.1 | 590.1 | 1.0 | False | None | None | False | None | False | 590.1 | 0 | 2338048 | 69107 | None | code145 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C | Nos | 540.75 | 540.75 | 27.0 | False | None | None | False | None | False | 14600.25 | 0 | 2338049 | 69107 | None | code146 | Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 600 A 4 x 75 x 10 mm Aluminium Strips | Mtr | 5906.25 | 5906.25 | 12.0 | False | None | None | False | None | False | 70875.0 | 0 | 2338050 | 69107 | None | code147 | Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 1000 A double run of 4 x 60 x 10 mm Aluminium Strips | Mtr | 11109.0 | 11109.0 | 18.0 | False | None | None | False | None | False | 199962.0 | 0 | 2338051 | 69107 | None | code148 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint 40*40*6mm | Mtr | 320.25 | 320.25 | 24.0 | False | None | None | False | None | False | 7686.0 | 0 | 2338052 | 69107 | None | code149 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint 50x50x6mm | Mtr | 414.75 | 414.75 | 24.0 | False | None | None | False | None | False | 9954.0 | 0 | 2338053 | 69107 | None | code150 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint 75 x 75 x 6 mm | Mtr | 582.75 | 582.75 | 32.0 | False | None | None | False | None | False | 18648.0 | 0 | 2338054 | 69107 | None | code151 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint 50X100X50X6mm C channel | Mtr | 793.8 | 793.8 | 24.0 | False | None | None | False | None | False | 19051.2 | 0 | 2338055 | 69107 | None | code152 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint 75 x 150 x 75 x 6 mm C channel | Mtr | 972.3 | 972.3 | 18.0 | False | None | None | False | None | False | 17501.4 | 0 | 2338056 | 69107 | None | code153 | Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete14SWG | Sq CM | 0.53 | 0.53 | 425000.0 | False | None | None | False | None | False | 225250.0 | 0 | 2338057 | 69107 | None | code154 | Auxiliary relay/contactor for control circuit | Nos | 2334.15 | 2334.15 | 1.0 | False | None | None | False | None | False | 2334.15 | 0 | 2338058 | 69107 | None | code155 | Supplying of on load change over switches 4/3 poles, AC- 23A Duty, 415V, 50Hz, AC Supply. (Open Execution)125 A | Nos | 10842.3 | 10842.3 | 5.0 | False | None | None | False | None | False | 54211.5 | 0 | 2338059 | 69107 | None | code156 | Supplying of on load change over switches 4/3 poles, AC- 23A Duty, 415V, 50Hz, AC Supply. (Open Execution)630 A | Nos | 37580.55 | 37580.55 | 2.0 | False | None | None | False | None | False | 75161.1 | 0 | 2338060 | 69107 | None | code157 | Supplying of on load change over switches 4/3 poles, AC- 23A Duty, 415V, 50Hz, AC Supply. (Open Execution)800 A | Nos | 51114.0 | 51114.0 | 1.0 | False | None | None | False | None | False | 51114.0 | 0 | 2338061 | 69107 | None | code158 | Supplying and fixing HRC fuse link on existing switch fuse base with W loss as per IS-13703.Above 63 A to 200 A | Nos | 400.05 | 400.05 | 15.0 | False | None | None | False | None | False | 6000.75 | 0 | 2338062 | 69107 | None | code159 | Supplying and fixing HRC fuse link on existing switch fuse base with W loss as per IS-13703.Above 425 A to 630 A | Nos | 1205.4 | 1205.4 | 9.0 | False | None | None | False | None | False | 10848.6 | 0 | 2338063 | 69107 | None | code160 | Supplying of TPST with rewirable porcelain channels in SM enclosure. Made out of 14 SWG powder coated paint of approved
colour.32A | Nos | 1786.05 | 1786.05 | 2.0 | False | None | None | False | None | False | 3572.1 | 0 | 2338064 | 69107 | None | code161 | Supply and fixing of Multifunctional three phase monitoring relays suitable to monitor three phase mains. It monitors all phase parameters such as over/undervoltage, phase unbalance, phase failure as well as an interrupted neutral. The corresponding threshold values are adjustable. Phase sequence monitoring as well as an ON or OFF tripping delay are selectable. The tripping delay is adjustable over a range of instantaneous to 30 s (0, 0.1-30 s). voltage rating 180V - 280V AC | Nos | 18128.25 | 18128.25 | 1.0 | False | None | None | False | None | False | 18128.25 | 0 | 2338065 | 69107 | None | code162 | Automatic Power factor control panel Supplying and fixing Moulded Case Circuit Breaker(MCCB) over the existing wood/panel board using necessary screws,bolts,nuts,necessary phase separators,handle and wiring complete.Protection of Over load and Short circuit with adjustable thermal magnetic release,Microprocessor release shall have Earth Fault as per IS/IEC60947 2.(Icu=100%lcs).In 4P MCCB,all Poles should have protection for Short Cicrcuit / Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non Priority loads must be available in the MCCB.MCCB shall be provided with double insulation(insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open)Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.160 A 25 kA | Nos | 14119.35 | 14119.35 | 1.0 | False | None | None | False | None | False | 14119.35 | 0 | 2338066 | 69107 | None | code163 | Supplying and fixing of Shunt trip suitable for MCCB.CBCT | Nos | 1788.15 | 1788.15 | 1.0 | False | None | None | False | None | False | 1788.15 | 0 | 2338067 | 69107 | None | code164 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 Amps SP | Nos | 435.75 | 435.75 | 16.0 | False | None | None | False | None | False | 6972.0 | 0 | 2338068 | 69107 | None | code165 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.50-63 Amps TPN | Nos | 3242.4 | 3242.4 | 5.0 | False | None | None | False | None | False | 16212.0 | 0 | 2338069 | 69107 | None | code166 | Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board | Nos | 9717.75 | 9717.75 | 1.0 | False | None | None | False | None | False | 9717.75 | 0 | 2338070 | 69107 | None | code167 | Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy | Nos | 9780.75 | 9780.75 | 1.0 | False | None | None | False | None | False | 9780.75 | 0 | 2338071 | 69107 | None | code168 | Supplying, fixing and wiring 50/5 to 400/5A 5VA burden Current Transformer Class 0.5 accuracy with Tape Wound | Nos | 590.1 | 590.1 | 3.0 | False | None | None | False | None | False | 1770.3 | 0 | 2338072 | 69107 | None | code169 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C | Nos | 540.75 | 540.75 | 16.0 | False | None | None | False | None | False | 8652.0 | 0 | 2338073 | 69107 | None | code170 | Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete.250Amps 4x30x10mm Aluminium Strips | Mtr | 3606.75 | 3606.75 | 8.0 | False | None | None | False | None | False | 28854.0 | 0 | 2338074 | 69107 | None | code171 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.40*40*6mm | Mtr | 320.25 | 320.25 | 12.0 | False | None | None | False | None | False | 3843.0 | 0 | 2338075 | 69107 | None | code172 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.50x50x6mm | Mtr | 414.75 | 414.75 | 12.0 | False | None | None | False | None | False | 4977.0 | 0 | 2338076 | 69107 | None | code173 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.50X100X50X6mm C channe | Mtr | 793.8 | 793.8 | 24.0 | False | None | None | False | None | False | 19051.2 | 0 | 2338077 | 69107 | None | code174 | Supplying and fixing of 3 pole power contactor with NO/NC contacts on existing wood/panel boaard using necessary bolts,nuts, washers and wiring etc., completee with ac-3 rating and as per IS-13947 60Amps | Nos | 6247.5 | 6247.5 | 5.0 | False | None | None | False | None | False | 31237.5 | 0 | 2338078 | 69107 | None | code175 | Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 V grade, for power factor improvement of rotating machineries likeinduction motor | Kvar | 504.0 | 504.0 | 50.0 | False | None | None | False | None | False | 25200.0 | 0 | 2338079 | 69107 | None | code176 | Supplying, fixing and wiring Automatic Power Factor controller circuit unit fully, static units controlled by 14 stage microprocessor operation, relays LED display, self programming function for power stages and operating logic checking facility for healthy and efficient of each individual capacitor bank, measurement of network harmonics with indication when limit values are exceeded, Comprehensive displays with large, three phase LED display, Long term memory for settings, protection for over voltage, power factor correction fault and no voltage, to connect/ disconnect banks, with automatic recognition or with standard programs | Nos | 22722.0 | 22722.0 | 1.0 | False | None | None | False | None | False | 22722.0 | 0 | 2338080 | 69107 | None | code177 | Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete.14SWG | Sq CM | 0.53 | 0.53 | 95000.0 | False | None | None | False | None | False | 50350.0 | 0 | 2338081 | 69107 | None | code178 | Supply and fixing of Auxiliary contactor relay with 2 NO and 2 NC contact and operating coil voltage of 220V to 260V. fixed on existing wood/panel board using necessary bolts, nuts, washers and wiring etc | Each | 1396.5 | 1396.5 | 1.0 | False | None | None | False | None | False | 1396.5 | 0 | 2338082 | 69107 | None | code179 | Power Capacitors: Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 V grade, for power factor improvement of rotating machineries likeinduction motor UG CABLES | Kvar | 504.0 | 504.0 | 354.0 | False | None | None | False | None | False | 178416.0 | 0 | 2338083 | 69107 | None | code180 | Main side cable:- Supply of 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975. 240 Sqmm, 3.5 Core, (30 GI Strips - 4 x 0.8 mm) | Km | 905799.3 | 905799.3 | 0.05 | False | None | None | False | None | False | 45289.965 | 0 | 2338084 | 69107 | None | code181 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff.120 to 240 Sqmm | Km | 33891.9 | 33891.9 | 0.05 | False | None | None | False | None | False | 1694.595 | 0 | 2338085 | 69107 | None | code182 | Load side cable:- (load side) Supply of 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975. 240 Sqmm, 3.5 Core, (30 GI Strips - 4 x 0.8 mm) | Km | 905799.3 | 905799.3 | 0.04 | False | None | None | False | None | False | 36231.972 | 0 | 2338086 | 69107 | None | code183 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff.120 to 240 Sqmm | Km | 33891.9 | 33891.9 | 0.04 | False | None | None | False | None | False | 1355.676 | 0 | 2338087 | 69107 | None | code184 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975.50 Sqmm, 3.5 Core, (16 GI Strips - 4 x 0.8 mm) | Km | 187921.65 | 187921.65 | 0.02 | False | None | None | False | None | False | 3758.433 | 0 | 2338088 | 69107 | None | code185 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975.95 Sqmm, 3.5 Core, (21 GI Strips - 4 x 0.8 mm) | Km | 391875.75 | 391875.75 | 0.02 | False | None | None | False | None | False | 7837.515 | 0 | 2338089 | 69107 | None | code186 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff.35 to 95 Sqmm | Km | 32695.95 | 32695.95 | 0.04 | False | None | None | False | None | False | 1307.838 | 0 | 2338090 | 69107 | None | code187 | 16 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm) | Km | 148934.1 | 148934.1 | 0.03 | False | None | None | False | None | False | 4468.023 | 0 | 2338091 | 69107 | None | code188 | 25 Sqmm, 4 Core, (13 GI Strips - 4 x 0.8 mm) | Km | 188836.2 | 188836.2 | 0.02 | False | None | None | False | None | False | 3776.724 | 0 | 2338092 | 69107 | None | code189 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff.2.5 to 25 Sqmm | Km | 21930.3 | 21930.3 | 0.05 | False | None | None | False | None | False | 1096.515 | 0 | 2338093 | 69107 | None | code190 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990.4C x 1.5 mm2 | m | 98.7 | 98.7 | 10.0 | False | None | None | False | None | False | 987.0 | 0 | 2338094 | 69107 | None | code191 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990.8C x 1.5 mm2 | m | 165.9 | 165.9 | 15.0 | False | None | None | False | None | False | 2488.5 | 0 | 2338095 | 69107 | None | code192 | 11 KV HT XLPE CABLE:supply of 11 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975.120 Sqmm, (57 GI Wires - 2.5 mm Dia) | Km | 1180204.2 | 1180204.2 | 0.05 | False | None | None | False | None | False | 59010.21 | 0 | 2338096 | 69107 | None | code193 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff3x95 to 150 Sqmm | Km | 64388.1 | 64388.1 | 0.05 | False | None | None | False | None | False | 3219.405 | 0 | 2338097 | 69107 | None | code194 | ERECTION OF CAPACITORS: Foundation works | Nos | 7875.0 | 7875.0 | 2.0 | False | None | None | False | None | False | 15750.0 | 0 | 2338098 | 69107 | None | code195 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. 1 to 1.5 mtr | Cum | 254.1 | 254.1 | 15.75 | False | None | None | False | None | False | 4002.075 | 0 | 2338099 | 69107 | None | code196 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The ranite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, form work, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates for PCC | Cum | 6288.45 | 6288.45 | 2.37 | False | None | None | False | None | False | 14903.6265 | 0 | 2338100 | 69107 | None | code197 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing, form work, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - for footing (Consider 3% as form work charges for other type of foundation) | Cum | 6652.8 | 6652.8 | 1.51 | False | None | None | False | None | False | 10045.728 | 0 | 2338101 | 69107 | None | code198 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, form work, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Consider 35% as form work charges for Concrete walls) | Cum | 6804.0 | 6804.0 | 12.1 | False | None | None | False | None | False | 82328.4 | 0 | 2338102 | 69107 | None | code199 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) | MT | 93929.85 | 93929.85 | 1.09 | False | None | None | False | None | False | 102383.5365 | 0 | 2338103 | 69107 | None | code200 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge | Sqm | 253.05 | 253.05 | 60.48 | False | None | None | False | None | False | 15304.464 | 0 | 2338104 | 69107 | None | code201 | LAYING IN G.I. PIPE: supply and laying of MS Pipe 200 mm Dia with collar | Mtr | 1009.05 | 1009.05 | 30.0 | False | None | None | False | None | False | 30271.5 | 0 | 2338105 | 69107 | None | code202 | Cable Terminations: supply and fixing of Compression type Aluminium Tubular in Line Connector for Aluminum Conductor16 Sqmm | Nos | 3.15 | 3.15 | 48.0 | False | None | None | False | None | False | 151.2 | 0 | 2338106 | 69107 | None | code203 | supply and fixing of Compression type Aluminium Tubular in Line Connector for Aluminum Conductor25 Sqmm | Nos | 3.15 | 3.15 | 48.0 | False | None | None | False | None | False | 151.2 | 0 | 2338107 | 69107 | None | code204 | supply and fixing of Compression type Aluminium Tubular in Line Connector for Aluminum Conductor50 Sqmm | Nos | 7.35 | 7.35 | 48.0 | False | None | None | False | None | False | 352.8 | 0 | 2338108 | 69107 | None | code205 | supply and fixing of Compression type Aluminium Tubular in Line Connector for Aluminum Conductor 95 Sqmm | Nos | 12.6 | 12.6 | 48.0 | False | None | None | False | None | False | 604.8 | 0 | 2338109 | 69107 | None | code206 | supply and fixing of Compression type Aluminium Tubular in Line Connector for Aluminum Conductor 240 Sqmm | Nos | 55.65 | 55.65 | 80.0 | False | None | None | False | None | False | 4452.0 | 0 | 2338110 | 69107 | None | code207 | EARTHING: Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40 mm dia 2.9 mm thick 2.5m long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400 mm with a cast iron cover. The earth electrode shall have staggered holes of 12 mm dia and the electrode should be covered 150 mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts | Nos | 4468.8 | 4468.8 | 20.0 | False | None | None | False | None | False | 89376.0 | 0 | 2338111 | 69107 | None | code208 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. GI strip GI Strip. 50 x 6 mm GI strip | Mtr | 228.9 | 228.9 | 100.0 | False | None | None | False | None | False | 22890.0 | 0 | 2338112 | 69107 | None | code209 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. GI strip Copper strip. 25x3mm | Mtr | 598.5 | 598.5 | 30.0 | False | None | None | False | None | False | 17955.0 | 0 | 2338113 | 69107 | None | code210 | Manufacturing, providing, trasporting, rolling, lowering, laying, jointing and commissioning of ERW (Electric Resistance Welded)/ SAW (Submerged Arc Welded) MS pipes of Outer dia (Fe-410 grade) conforming to IS 3589-2001 with latest amendments, including perfect linking and welding of joints to correct position, cost of the pipes, conveyance, lead, lift charges, cost of all labour and giving satisfactory hydraulic test as per IS 3589-2001 with latest amendments for test pressure and working pressure both at factory and site etc. complete as per detailed specifications inside with CM 1:1.5 lining of minimum 10mm thick for pipes upto 610mm OD and with minimum 12mm thick beyond 610mm OD and out side with minimum 25mm thick coating in CM 1:3 over 50 x 50mm weld mesh of 13 gauge, including loading and unloading of pipes for the following diameters and specified thickness of plate as noted below, including bailing out of water wherever necessary. (Contractor will make his own arrangements for procuring water for testing). For MS Pipes of 406mm dia Note: a) No Negative tolerance in respect of thickness is pemissible. b) Basic Cost of MS Plate is considered as Rs.71,700/- per MT c) The pipe costs are FOR destination anywhere in Karnataka Pipe of 406mm dia-6.4mm thick | Rmtr | 8657.25 | 8657.25 | 13.0 | False | None | None | False | None | False | 112544.25 | 0 | 2338114 | 69107 | None | code211 | Manufacturing, providing, transporting, rolling, lowering, laying, jointing & testing and commissioning of MS specials of minimum 8mm thick such as bends, tail pieces, reduces etc. conforming to IS-7322:1985 with latest amendments and including perfect linking and welding of joints to correct position includng cost and conveyance of materials with all lead and lifts, cost all labour and giving satisfactory hydraulic test as per IS:3589:2001 with latest amendments for test pressure and working pressure both at factory and site etc. complete as per detailed specifications with inside lining two coat of food grade epoxy painting of approved make with each coat of 250 micron thick (after dry) over one coat of food grade epoxy primer of approved make with minium of 50 micron thick (after dry) and outside 25mm thick coating in CM 1:3 by providing 50x50mm weld mesh including loading and unloading of the pipes for the following category to suit PSC / MS / CI / AC / DI / PVC pipes. The weight of MS shell only by considered before lining and coating for arriving at the rate. The thickness of plate will be specified by the engineer. (Contractor will make his own arrangements for procuring water for testing) DO-for Bends, Tail Pieces, reducers, Test gaps, TEES- Upto & Inclusive of 500mm dia pipe.Fire Fighting Equipment and safty equipment | Kgs | 178.5 | 178.5 | 100.0 | False | None | None | False | None | False | 17850.0 | 0 | 2338115 | 69107 | None | code212 | C02 Gas aluminium body Squeeze grip Fire Extinugisher, Used Unused Mechanism, Squeeze Grip, Gross Weight 5.16 Kg. empty Weight 3.16Kg. Can Height 615M M Diameter 111MM, Discharge Time less than 8 Sees, Controllable discharge mechanism, Applicable on Class 8&C Fire, 8 Rating 138, Can Constuction: Cold Impact Extrusion, Valve Construction : Forging & Machining, Internal Coating of Can : Not Applicable, External coating of Can : Spray Painting, Aluminium metal ISO & PESO Approved, 3 Year Warranty. including cost cost of supporting materials like MS stand & accessaries if it is fixing n floor / MS brackets & accessories if it is fixing on wall,, labour, usage charges of machinery complete as per specifications. complete | Nos | 4305.0 | 4305.0 | 2.0 | False | None | None | False | None | False | 8610.0 | 0 | 2338116 | 69107 | None | code213 | Supplying of first aid box. Completee | Nos | 630.0 | 630.0 | 1.0 | False | None | None | False | None | False | 630.0 | 0 | 2338117 | 69107 | None | code214 | Supplying of FIRST AID CHART with lamination. Complete | Nos | 420.0 | 420.0 | 1.0 | False | None | None | False | None | False | 420.0 | 0 | 2338118 | 69107 | None | code215 | Supplying and installation of RUBBER MAT 1mtr x 1mtr -1Omm thick. complete including cost of materials, labour, usage charges of machinery complete as per specifications | Nos | 1995.0 | 1995.0 | 1.0 | False | None | None | False | None | False | 1995.0 | 0 | 2338119 | 69107 | None | code216 | Supplying of Hand gloves. Complete | Nos | 1023.75 | 1023.75 | 1.0 | False | None | None | False | None | False | 1023.75 | 0 | 2338120 | 69107 | None | code217 | Supplying of four bucket stand alongwith buckets. Complete | No | 1942.5 | 1942.5 | 1.0 | False | None | None | False | None | False | 1942.5 | 0 | 2338121 | 69107 | None | code218 | Providing and Fixing Fire force board size of 3'x2' made out to Acrylic sheet of 3mm thick and fixing with Stainless Steel finished studs etc. complete including cost of materials, labour, usage charges of machinery complete as per specifications | Nos | 2625.0 | 2625.0 | 1.0 | False | None | None | False | None | False | 2625.0 | 0 | 2338122 | 69107 | None | code219 | Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in Charge | Kgs | 118.65 | 118.65 | 1100.0 | False | None | None | False | None | False | 130515.0 | 0 | 2338123 | 69107 | None | code220 | Providing and fixing G.I. chain link fabric fencing of required width in
mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts,
bolts and washers as required complete as per the direction of Engineer in-charge. (Made of G.I. wire of dia 4 mm | Sqm | 843.15 | 843.15 | 150.0 | False | None | None | False | None | False | 126472.5 | 0 | 2338124 | 69107 | None | code221 | 11kV HT Metering cubical of different CT Ratio Both side entry type with 3CT & 3PTs with transparent cover TTB,with 30x8mm Copper Bus bars,modem and 2nos of Meters for 3 Phase 4 Wire Metering WITHOUT Load break Switch (HT Metering Box Fabricated out of 3mm MS Sheet duly epoxy powder coated)as per revised specification.Dwg No. BESCOM/GM/QS&S/--Dtd 2411.2018 | No | 255645.6 | 255645.6 | 1.0 | False | None | None | False | None | False | 255645.6 | 0 | 2338125 | 69107 | None | code222 | Load Break switches with Pane | No | 76900.95 | 76900.95 | 1.0 | False | None | None | False | None | False | 76900.95 | 0 | 2338126 | 69107 | None | code223 | Erection of HT metering Cubicle on Platform | No | 1936.2 | 1936.2 | 1.0 | False | None | None | False | None | False | 1936.2 | 0 | 2338127 | 69107 | None | code224 | Erection Alignment and fixing of Load break switch on the platform | No | 2181.9 | 2181.9 | 1.0 | False | None | None | False | None | False | 2181.9 | 0 | 2338128 | 69107 | None | code225 | Cable End Seals:- Supply and fixing of Heat Shrinkable Indoor Type Cable Termination Kit for XLPE Cable.3x240 Sqmm. | Set | 4925.55 | 4925.55 | 6.0 | False | None | None | False | None | False | 29553.3 | 0 | 2338129 | 69107 | None | code226 | Cable End Seals:- Supply and fixing of Heat Shrinkable Outdoor Type Cable Termination Kit for XLPE Cable.3x240 Sqmm | Set | 5583.9 | 5583.9 | 2.0 | False | None | None | False | None | False | 11167.8 | 0 | 2338130 | 69107 | None | code227 | CONTROL CABLE:Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990.4C x 2.5 mm2 | Per Mtr | 155.4 | 155.4 | 100.0 | False | None | None | False | None | False | 15540.0 | 0 | 2338131 | 69107 | None | code228 | CONTROL CABLE:Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990.6C x 2.5 mm2 | Per Mtr | 285.6 | 285.6 | 50.0 | False | None | None | False | None | False | 14280.0 | 0 | 2338132 | 69107 | None | code229 | 2 mm thick perforated cable GI tray with on existing MS angle support using necessary GI bolts/nuts and washer or welding as required 300 x 50 mm | Mtr | 616.35 | 616.35 | 50.0 | False | None | None | False | None | False | 30817.5 | 0 | 2338133 | 69107 | None | code230 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. ( Icu = Ics)700-800 A 50 kA | No | 52395.0 | 52395.0 | 5.0 | False | None | None | False | None | False | 261975.0 | 0 | 2338134 | 69107 | None | code231 | Supplying and fixing of Shunt trip suitable for MCCB.CBCT | No | 1788.15 | 1788.15 | 1.0 | False | None | None | False | None | False | 1788.15 | 0 | 2338135 | 69107 | None | code232 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 Amps SP | No | 435.75 | 435.75 | 24.0 | False | None | None | False | None | False | 10458.0 | 0 | 2338136 | 69107 | None | code233 | Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board | No | 9717.75 | 9717.75 | 1.0 | False | None | None | False | None | False | 9717.75 | 0 | 2338137 | 69107 | None | code234 | Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy | No | 9780.75 | 9780.75 | 1.0 | False | None | None | False | None | False | 9780.75 | 0 | 2338138 | 69107 | None | code235 | Supplying, fixing and wiring 1000/5A to 1600/5A 15VA Burden class 1 Current Transformer | No | 882.0 | 882.0 | 1.0 | False | None | None | False | None | False | 882.0 | 0 | 2338139 | 69107 | None | code236 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C | No | 540.75 | 540.75 | 24.0 | False | None | None | False | None | False | 12978.0 | 0 | 2338140 | 69107 | None | code237 | Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 1000 A double run of 4 x 60 x 10 mm Aluminium Strips | Mtr | 11109.0 | 11109.0 | 6.0 | False | None | None | False | None | False | 66654.0 | 0 | 2338141 | 69107 | None | code238 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint50x50x6mm | Mtr | 414.75 | 414.75 | 12.0 | False | None | None | False | None | False | 4977.0 | 0 | 2338142 | 69107 | None | code239 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint 75 x 75 x 6 mm | Mtr | 582.75 | 582.75 | 12.0 | False | None | None | False | None | False | 6993.0 | 0 | 2338143 | 69107 | None | code240 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint 50X100X50X6mm C channel | Mtr | 793.8 | 793.8 | 12.0 | False | None | None | False | None | False | 9525.6 | 0 | 2338144 | 69107 | None | code241 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint 75 x 150 x 75 x 6 mm C channel | Mtr | 972.3 | 972.3 | 12.0 | False | None | None | False | None | False | 11667.6 | 0 | 2338145 | 69107 | None | code242 | Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete | Sq CM | 0.53 | 0.53 | 295000.0 | False | None | None | False | None | False | 156350.0 | 0 |
|