createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1706602901311
version5
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee5000.00
emd675000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose12-02-2024 11:25:00
tenderQueryClose12-02-2024 11:20:00
technicalBidOpen13-02-2024 11:30:00
publishedDate02-02-2024 17:14:37
publishedByPostDMA_EE6_CC_MYS
publishedByUserKPE13419 - B NAGARAJ
bidValidityPeriod180
noOfCalls1
preBidMeetingDate05-02-2024 11:30:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonAkshatha M
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber8197967371
tenderSupplierListNone
tenderSchedule
createdTs1706602901378
version6
createdDateNone
modifiedDateNone
tenderNumberDMA/2023-24/WS/WORK_INDENT13619
titleProviding 400 mm dia DI rising main from Kesare STP to Devanoor lake and construction of storage tank and commissioning of pumpsets at Kesare STP, Mysore
descriptionProviding 400 mm dia DI rising main from Kesare STP to Devanoor lake and construction of storage tank and commissioning of pumpsets at Kesare STP, Mysore
categoryWORKS
categoryTextWorks
ecv38126508.97
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2163
locationNameDMA City Corporation Mysuru
provisionalAmount45000000.0
groupOverheadTotalNone
fileNumberMCCEEWSUGDE20125012024
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17066029010000NoneNoneWater supply/sewage linesProviding 400 mm dia Di raising main from kesare STP to devanoor lake and construction of storage tank and commissioning of pumpsets at Kesare STP, Mysore38126508.97
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
233790469107Nonecode01Cutting Asphalt /Concrete road surface using machine cutter for leakage pit with earth work excavation in all classifications of soil including all lead and lifts bailing out water with pumps including barricading, danger lighting etc., as per requirement and disposing of the excavated stuff as directed. After attending the leak, refilling the trench for 30 cm depth quarry dust above and around pipelines and balance with available earth in layers not exceeding 20 cms in depth, compacting Each deposited layer by ramming including watering and consolidation by mechanical means approved by Engineer Incharge. (Work to be carried out as per leak repair manual and the rate includes hire charges of dewatering Pump, tractor,Jeep with all kinds of Labour in a Complete manner).Cum1214.851214.8575.0FalseNoneNoneFalseNoneFalse91113.750
233790569107Nonecode02Clearing and grubbing land including uprooting rank vegetable grass, bushes, shrubs, saplings and trees upto 300mm girth by manual means, in areas of light jungle, removal of stumps, disposal of unserviceable materials, stacking of serviceable materials from road boundary etc. including cost of labour charges, all lead and lifts, etc. complete as directed by the Engineer in charge.Sqm8.48.4750.0FalseNoneNoneFalseNoneFalse6300.00
233790669107Nonecode03Earth work excavation for pipeline trenches in all kinds of soils by mechanical means above 600 mm trench width as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & boning rods at every 100 mm whevere necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata. 'All kinds of soils. Depth upto 1.50 mCum275.1275.13834.56FalseNoneNoneFalseNoneFalse1054887.4560
233790769107Nonecode04Earth work excavation for pipeline trenches in all kinds of soils by mechanical means above 600 mm trench width as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & boning rods at every 100 mm whevere necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata.Ordinary/soft rock (without requiring blasting) Depth upto 1.50 mCum476.7476.7676.69FalseNoneNoneFalseNoneFalse322578.1230
233790869107Nonecode05Earth work excavation for pipeline trenches in all kinds of soils by mechanical means above 600 mm trench width as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & boning rods at every 100 mm whevere necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata.Hard rock (blasting prohibited) Depth upto 1.50 mCum1064.71064.7225.56FalseNoneNoneFalseNoneFalse240153.7320
233790969107Nonecode06Providing bedding for the pipeline trenches in black cotton and rock reaches including watering and consolidation by punners etc. complete with all lead and lift with: Murrum/GravelCum375.95375.95105.0FalseNoneNoneFalseNoneFalse39474.750
233791069107Nonecode07Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specificationsCum168.0168.04511.25FalseNoneNoneFalseNoneFalse757890.00
233791169107Nonecode08Construction of Granular Sub-Base of required grading as per design mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 For Grading -V MaterialCum2611.352611.35111.0FalseNoneNoneFalseNoneFalse289859.850
233791269107Nonecode09Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density.Cum2686.952686.95111.0FalseNoneNoneFalseNoneFalse298251.450
233791369107Nonecode10Prime Coat over WMM/WBM Providing and applying primer coat with SS1 grade Bitumen Emulsion on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.90 kg per m2 using mechanical means.Sqm43.0543.05740.03FalseNoneNoneFalseNoneFalse31858.29150
233791469107Nonecode11Bituminous Macadam Grading - II for traffic greaterthan20 MSA Providing and laying Bituminous Macadam with 40/60 TPH capacity hot mix plant using crushed aggregates of specified grading premixed with bituminous binder VG-40 @ 3.4% by weight of mix, transported to site, laid over a previously prepared surface with mechanical paver finisher to the required grade, level and alignment and rolled as per clauses 501.6 and 501.7 to achieve the desired compactionCum8284.58284.537.0FalseNoneNoneFalseNoneFalse306526.50
233791569107Nonecode12Tack coat on Bituminous surface Providing and applying tack coat with RS1 Bituminous Emulsion using emulsion pressure distributor at the rate of 0.20 kg/m2 on the prepared bituminous surface cleaned with mechanical broomSqm12.612.6740.03FalseNoneNoneFalseNoneFalse9324.3780
233791669107Nonecode13Providing and laying Semi Dense Bituminous Concrete with 40/60 TPH capacity hot mix plant batch type using crushed aggregates of specified grading premixed with bituminous binder VG-30 @ 5% by weight of mix and filler, transported to site, laid over a previously prepared surface with mechanical paver finisher to the required grade, level and alignment and rolled as per MoRTH V revision.Cum10659.610659.618.5FalseNoneNoneFalseNoneFalse197202.60
233791769107Nonecode14Bituminous Concrete Grading I for traffic greaterthan20 MSA Providing and laying Bituminous Concrete with 40/60 TPH capacity hot mix plant using crushed aggregates of specified grading, premixed with bituminous binder VG-40 @ 5.2 per cent of mix and filler, transporting the hot mix to work site, laying with mechanical paver finisher to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORTH specification clause No. 507 complete in all respectsCum11552.111552.155.5FalseNoneNoneFalseNoneFalse641141.550
233791869107Nonecode15Providing and laying Ductile Iron pipes of class K7 conforming to IS 8329:2000 with latest amendments, conveyiing to work site, rolling and lowering into trenches, laying true to line, level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations, cutting of pipes wherever necessary, jointing with DI specials (excluding cost of specials) and rubber gaskets, cleaning the socket and spigot end with soap solution, applying soft soap to the socket and spigot ends before insertion of rubber gaskets, jacking and fixing in perfect conditions etc. The cost to include soap solution, soft soap, waste etc. and giving necessary hydraulic test to the required pressure as per ISS with all lead and lifts and cost of all jointing materials. (The contractor will make his own arrangements for water for testing. Earth work excavation in trenches to be measured and paid for seperately) Note: In sewerage projects for internal cement mortal lining ( CML ) of DI pipes, if High Alumina Cement ( HAC ) as recommended in Annexure B clause 16.3 of IS8329:2000 is considered in place of Slag or Sulphate Resistance Cement ( SRC ), the cost of pipes may be increased by 5-6% from the prices listed. 400 mm dia DI PIPEMtr6274.86274.83000.0FalseNoneNoneFalseNoneFalse18824400.00
233791969107Nonecode16Supplying and fixing DI Resilient seated soft sealing SLUICE VALVE of various dia.with body, bonnet of ductile iron (DI) conforming to IS-1865 and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100% leak proof with face dimensions as per BS 5163-89 / IS 14846-2000 / DN 3202 F4/F5. The stem sealing should be with toroidal sealing rings (minimum 2 "O" rings). Body and bonut should be coated with Electrostatically applied Epoxy Powder Coating with minium coating thickness of 250 micron both inside and out side. The rate is inclusive of cost of valve, T.P set, galvanized bolts & nuts and rubber insertions etc. but excluding earth work. PN 16. 80 mmEach10912.710912.77.0FalseNoneNoneFalseNoneFalse76388.90
233792069107Nonecode17Supplying and fixing DI Resilient seated soft sealing SLUICE VALVE of various dia.with body, bonnet of ductile iron (DI) conforming to IS-1865 and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100% leak proof with face dimensions as per BS 5163-89 / IS 14846-2000 / DN 3202 F4/F5. The stem sealing should be with toroidal sealing rings (minimum 2 "O" rings). Body and bonut should be coated with Electrostatically applied Epoxy Powder Coating with minium coating thickness of 250 micron both inside and out side. The rate is inclusive of cost of valve, T.P set, galvanized bolts & nuts and rubber insertions etc. but excluding earth work. PN 16. 200 mm (Sluice for Scour)Each34687.834687.83.0FalseNoneNoneFalseNoneFalse104063.40
233792169107Nonecode18Supplying and fixing DI Resilient seated soft sealing SLUICE VALVE of various dia.with body, bonnet of ductile iron (DI) conforming to IS-1865 and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100% leak proof with face dimensions as per BS 5163-89 / IS 14846-2000 / DN 3202 F4/F5. The stem sealing should be with toroidal sealing rings (minimum 2 "O" rings). Body and bonut should be coated with Electrostatically applied Epoxy Powder Coating with minium coating thickness of 250 micron both inside and out side. The rate is inclusive of cost of valve, T.P set, galvanized bolts & nuts and rubber insertions etc. but excluding earth work. PN 16. 400 mm (Sluice for ScourEach175321.6175321.62.0FalseNoneNoneFalseNoneFalse350643.20
233792269107Nonecode19Providing and fixing of Single/ Double chamber triple function tamper proof (Both the orifces to be housed in the single chamber) Air valves with Body and cover in Ductile cast iron of grade GGG 40/ 50. All internal parts such as float, shell with appurtenances., all cover bolts of austenitic alloy / SS 304 steel, DN 50 float of HOSTAFLON / SS 304 and gaskers and seals of EPDM. Epoxy powder coating (EP-P) inside and outside colour blue RAL5005. The valves should be designed for all the three functions i.e., 1. Large orifice for venting of large air volumes on start up. 2. Large orifice for intake of large air volumes. 3. Small orifice for discharge of pressurized air during operation. PN 16. 80 mm diaEach30455.2530455.257.0FalseNoneNoneFalseNoneFalse213186.750
233792369107Nonecode20Supplying and fixing of DI specials with ISI mark confoming to IS 9523 / 2000 suitable for jointing 100 mm to 600 mm dia DI pipes coated with rust prevention coatings. A) External coating: a) Metalic zinc with finishing layer of bituminous as per Annexure “A” of IS:9523/2000 b) Zinc rich paint with finishing layer of bituminous as per Annexure “A”of IS:9523 / 2000 c) Bituminous paint as per Annexure “C” of IS:9523 / 2000 B) Internal Lining:a) Portaland Cement (with or without additives) mortar as per Annexure - “B” of IS:9523/2000 b) Cement Mortar with coat coat as per Annexure “B” of IS:9523 / 2000 c) Bituminous paint as per Annexure “C” of IS:9523 / 2000 For bends, test gaps, Tees. Reducers for 400mm dia pipe for linking the inlet and out letKgs197.4197.45000.0FalseNoneNoneFalseNoneFalse987000.00
233792469107Nonecode21Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Valve chambers In all kinds of soils Depth upto 1.5 m (1.20 x 1.20 x 1.50)MCum254.1254.127.88FalseNoneNoneFalseNoneFalse7084.3080
233792569107Nonecode22Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Valve chambers Depth exceeding 1.5m, but not exceeding 3 m (1.20 x 1.20 x 1.50)MCum271.95271.957.11FalseNoneNoneFalseNoneFalse1933.56450
233792669107Nonecode23Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical pecifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools,usage & other appurtenances required to complete the work.In ordinary/soft rock without blasting upto 1.5 m depth (1.20 x 1.20 x 1.50)MCum313.95313.954.92FalseNoneNoneFalseNoneFalse1544.6340
233792769107Nonecode24Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical pecifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools,usage & other appurtenances required to complete the work.In ordinary/soft rock without blasting for Depth exceeding 1.5m, but not exceeding 3 m (1.20 x 1.20 x 1.50)MCum467.25467.254.743FalseNoneNoneFalseNoneFalse2216.166750
233792869107Nonecode25Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, form work, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates for PCCCum6288.456288.453.791FalseNoneNoneFalseNoneFalse23839.513950
233792969107Nonecode26Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing, form work, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - for footing (Consider 3% as form work charges for other type of foundation) RaftCum6652.86652.82.688FalseNoneNoneFalseNoneFalse17882.72640
233793069107Nonecode27Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, form work, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Consider 35% as form work charges for Concrete walls) Side wallCum9185.49185.414.448FalseNoneNoneFalseNoneFalse132710.65920
233793169107Nonecode28Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)MT82961.5582961.551.371FalseNoneNoneFalseNoneFalse113740.285050
233793269107Nonecode29Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Side wallSqm253.05253.0586.24FalseNoneNoneFalseNoneFalse21823.0320
233793369107Nonecode30Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications For Valve chamber size (1.20X1.20X1.50)mCum168.0168.044.26FalseNoneNoneFalseNoneFalse7435.680
233793469107Nonecode31Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work In all kinds of soils Depth upto 1.5 m (1.50X1.50X1.50)mCum254.1254.115.938FalseNoneNoneFalseNoneFalse4049.84580
233793569107Nonecode32Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work Depth exceeding 1.5m, but not exceeding 3 m(1.50X1.50X1.50)mCum271.95271.952.625FalseNoneNoneFalseNoneFalse713.868750
233793669107Nonecode33Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical pecifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools,usage & other appurtenances required to complete the work.In ordinary/soft rock without blasting upto 1.5 m depthCum313.95313.951.935FalseNoneNoneFalseNoneFalse607.493250
233793769107Nonecode34Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical pecifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools,usage & other appurtenances required to complete the work. In ordinary/soft rock without blasting for Depth exceeding 1.5m, but not exceeding 3 mCum467.25467.251.75FalseNoneNoneFalseNoneFalse817.68750
233793869107Nonecode35Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, form work, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates for PCCCum6288.456288.451.452FalseNoneNoneFalseNoneFalse9130.82940
233793969107Nonecode36Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing, form work, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - for footing (Consider 3% as form work charges for other type of foundation) RaftCum6652.86652.81.083FalseNoneNoneFalseNoneFalse7204.98240
233794069107Nonecode37Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, form work, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Consider 35% as form work charges for Concrete walls) Side wall & Covering slabCum9185.49185.45.163FalseNoneNoneFalseNoneFalse47424.22020
233794169107Nonecode38Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)MT82961.5582961.550.5FalseNoneNoneFalseNoneFalse41480.7750
233794269107Nonecode39Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Side wall & cover slabSqm253.05253.0532.44FalseNoneNoneFalseNoneFalse8208.9420
233794369107Nonecode40Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specificationsCum168.0168.017.28FalseNoneNoneFalseNoneFalse2903.040
233794469107Nonecode41Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technicalspecifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in aradius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 mCum254.1254.19.72FalseNoneNoneFalseNoneFalse2469.8520
233794569107Nonecode42Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technicalspecifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in aradius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depthCum271.95271.956.48FalseNoneNoneFalseNoneFalse1762.2360
233794669107Nonecode43Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The ranite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)complete for Anchor Blocks/Thrust Blocks. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Consider 3% as form work charges for other type of foundation)Cum6639.156639.1517.28FalseNoneNoneFalseNoneFalse114724.5120
233794769107Nonecode44Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)MT82961.5582961.551.38FalseNoneNoneFalseNoneFalse114486.9390
233794869107Nonecode45Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specificationsCum168.0168.09.72FalseNoneNoneFalseNoneFalse1632.960
233794969107Nonecode46Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead By Mechanical Means Cement Concrete Grade M-15 & M-20Cum754.95754.952.25FalseNoneNoneFalseNoneFalse1698.63750
233795069107Nonecode47Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead By Mechanical Means Dismantling Brick / Tile work / rubble masonry / pitching / etc by mechanical meansCum189.0189.07.2FalseNoneNoneFalseNoneFalse1360.80
233795169107Nonecode48Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates PCCCum6288.456288.452.25FalseNoneNoneFalseNoneFalse14149.01250
233795269107Nonecode49Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6708.456708.457.2FalseNoneNoneFalseNoneFalse48300.840
233795369107Nonecode50Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Foundation, (Consider 5% as form work charges for Sub structure of Cross drainages) Deck SlabCum6601.356601.352.25FalseNoneNoneFalseNoneFalse14853.03750
233795469107Nonecode51Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)MT82961.5582961.550.18FalseNoneNoneFalseNoneFalse14933.0790
233795569107Nonecode52Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.In all kinds of soils Depth upto 1.5 mCum254.1254.112.68FalseNoneNoneFalseNoneFalse3221.9880
233795669107Nonecode53Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.In ordinary/soft rock without blasting upto 1.5 m depthCum313.95313.9512.68FalseNoneNoneFalseNoneFalse3980.8860
233795769107Nonecode54Providing and Filling in foundation with granite / trap broken metal 100mm and down size with approved M-Sand including hand packing, ramming, watering including cost of all materials and labour with all lead and lift complete as per specificationsCum2816.12816.15.0FalseNoneNoneFalseNoneFalse14080.50
233795869107Nonecode55Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates 1 x 1.0 x 1.0 x0.15Cum6602.876602.871.5FalseNoneNoneFalseNoneFalse9904.3050
233795969107Nonecode56Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing, form work, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - for footing (Consider 3% as form work charges for other type of foundationCum6652.86652.87.0FalseNoneNoneFalseNoneFalse46569.60
233796069107Nonecode57Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separatelyMT82961.5582961.550.7FalseNoneNoneFalseNoneFalse58073.0850
233796169107Nonecode58Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specificationsCum168.0168.025.35FalseNoneNoneFalseNoneFalse4258.80
233796269107Nonecode59Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 mCum107.1107.164.54FalseNoneNoneFalseNoneFalse6912.2340
233796369107Nonecode60Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depthCum381.15381.1538.52FalseNoneNoneFalseNoneFalse14681.8980
233796469107Nonecode61Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work Depth exceeding 1.5 m, but not exceeding 3 mCum446.25446.2526.37FalseNoneNoneFalseNoneFalse11767.61250
233796569107Nonecode62Earth work excavation for FOUNDATION by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work In Hard Rock ( requiring blasting) Depth upto 1.50mCum581.7581.738.52FalseNoneNoneFalseNoneFalse22407.0840
233796669107Nonecode63Earth work excavation for FOUNDATION by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work Depth exceeding 1.5 m, but not exceeding 3 mCum654.15654.1526.37FalseNoneNoneFalseNoneFalse17249.93550
233796769107Nonecode64Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregatesCum6527.856527.8541.54FalseNoneNoneFalseNoneFalse271166.8890
233796869107Nonecode65Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6708.456708.4518.58FalseNoneNoneFalseNoneFalse124643.0010
233796969107Nonecode66Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Add 70% for columns and 50% rate for Form works) Column footing , Column upto GL pedestal, Above GL, Pump pit raft , Pump pit sidesCum11310.7611310.7655.56FalseNoneNoneFalseNoneFalse628425.82560
233797069107Nonecode67Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Add 70% for columns and 50% rate for Form works)plinth Beams above G.L, Lintel, roof beam, Corbel beam ,Corbel , roof slab,Chejja main dooor , Windows ChejjaCum9979.29979.232.55FalseNoneNoneFalseNoneFalse324822.960
233797169107Nonecode68Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum9317.79317.725.19FalseNoneNoneFalseNoneFalse234712.8630
233797269107Nonecode69Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Sqm2764.652764.659.0FalseNoneNoneFalseNoneFalse24881.850
233797369107Nonecode70Providing and fixing ball bearing for rolling shutters including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Nos423.15423.151.0FalseNoneNoneFalseNoneFalse423.150
233797469107Nonecode71Extra for providing Manually operated Bevel Gear Box for operating rolling shutters including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Nos3240.33240.31.0FalseNoneNoneFalseNoneFalse3240.30
233797569107Nonecode72Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6 PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets -grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame.The outer frame having an overall size of 44mm width x 40mmheight with reinforcement of 1mm thickness and Sash with overall size of 27mm X 53mm with UPVC honeycomb structure inside in lieu of GI reinforcement. Coextruded Glazing bead for fixing of glass shall be of size 9.5mm x 21.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with Crescent Locks. Wall thickness of frame & sash shall be of 2 mm.Maximum possible size 1219mm x 1219mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm5274.155274.1529.25FalseNoneNoneFalseNoneFalse154268.88750
233797669107Nonecode73Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc.Sqm192.15192.15490.0FalseNoneNoneFalseNoneFalse94153.50
233797769107Nonecode74Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm267.75267.75273.75FalseNoneNoneFalseNoneFalse73296.56250
233797869107Nonecode75Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm309.75309.75315.35FalseNoneNoneFalseNoneFalse97679.66250
233797969107Nonecode76Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge. basementSqm267.75267.7517.91FalseNoneNoneFalseNoneFalse4795.40250
233798069107Nonecode77Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm55.6555.65315.35FalseNoneNoneFalseNoneFalse17549.22750
233798169107Nonecode78Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm93.4593.45425.75FalseNoneNoneFalseNoneFalse39786.33750
233798269107Nonecode79Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm133.35133.35273.75FalseNoneNoneFalseNoneFalse36504.56250
233798369107Nonecode80Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm175.35175.3518.0FalseNoneNoneFalseNoneFalse3156.30
233798469107Nonecode81Providing PVC ringtite pipes conforming to IS 4985:2000 with latestamendments and conveying to worksite, rolling and lowering intotrenches, laying true to line and level and perfect linking at joints, testingand commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:Mtr308.7308.716.0FalseNoneNoneFalseNoneFalse4939.20
233798569107Nonecode82Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per direction of Engineer incharge.Sqm840.0840.084.0FalseNoneNoneFalseNoneFalse70560.00
233798669107Nonecode83Providing Thermo-Mechanically Treated bars of grade Fe-550D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)Kg93929.8593929.859.2524FalseNoneNoneFalseNoneFalse869076.544140
233798769107Nonecode84Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.Sqm857.85857.85108.24FalseNoneNoneFalseNoneFalse92853.6840
233798869107Nonecode85Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum279.3279.3218.61FalseNoneNoneFalseNoneFalse61057.7730
233798969107Nonecode86SupplyingheavygaugePVCconduitpipe......mmdia..........mmthickconfirmingtoIS2509withsuitablesizebends,metal/PVCJunctionboxes,adhesivepasteetc.,andrunningbeforeconcretingtheslab.TheconduitshouldbetiedtothereinforcementrodsbyusingbindingwiresandunusedwaysofjunctionboxesandpipeendsshouldbecoveredusingPVCendenclosures,runwith18SWGGIfishwire wherever necessaryMtr78.078.0150.0FalseNoneNoneFalseNoneFalse11700.00
233799069107Nonecode87SupplyingheavygaugePVCConduitPipe....dia.......mmthickwithsuitablesizebends,metaljunctionboxesadhesivepasteetc.,bygroovecuttinginthewallandfixingbybracingUorJhooksandcementplasteringuptothewallsurfaceandrunwith18SWGGIfish wire run throughout the conduit wherever necessary.Mtr79.079.0150.0FalseNoneNoneFalseNoneFalse11850.00
233799169107Nonecode88Supplying and fixing PVC/metal conduit Deep junction box 19/20 mm deep Junction boxEach61.061.040.0FalseNoneNoneFalseNoneFalse2440.00
233799269107Nonecode89Supplyingandflushmountingpowdercoated/galvanizedmetalboxsuitableformountingmodularswitchplates.Theboxshouldbefirmly Flush mounted after due groove cutting in Brick/Stone/C.C wall 1- 3 WayEach159.0159.010.0FalseNoneNoneFalseNoneFalse1590.00
233799369107Nonecode90Supplyingandfixingsuperiorqualitymodularswitchmountingpolycarbonateplatewithnecessarysupportingbackplatewithrequirednos.ofmachinescrews,boltsnutsetc.,completeontheexisting metal/PVC box. 6 ModuleEach234.0234.010.0FalseNoneNoneFalseNoneFalse2340.00
233799469107Nonecode91Supplyingandfixingsuperiorqualitymodularswitchmountingpolycarbonateplatewithnecessarysupportingbackplatewithrequirednos.ofmachinescrews,boltsnutsetc.,completeonthe existing metal/PVC box.Each161.0161.010.0FalseNoneNoneFalseNoneFalse1610.00
233799569107Nonecode92Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8MouduleEach284.0284.020.0FalseNoneNoneFalseNoneFalse5680.00
233799669107Nonecode93Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate.. Is 3854 and IS 1293. Using Group "A" materials 6Amps one way.Each88.088.020.0FalseNoneNoneFalseNoneFalse1760.00
233799769107Nonecode94Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate.. Is 3854 and IS 1293. Using Group "A" materials 6Amps Two way.Each152.0152.020.0FalseNoneNoneFalseNoneFalse3040.00
233799869107Nonecode95Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate.. Is 3854 and IS 1293. Using Group "A" materials 6Amps 3way socket.Each147.0147.05.0FalseNoneNoneFalseNoneFalse735.00
233799969107Nonecode96Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate.. Is 3854 and IS 1293. Using Group "A" materials Stepped Fan Regulator.Each357.0357.04.0FalseNoneNoneFalseNoneFalse1428.00
233800069107Nonecode97Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate.. Is 3854 and IS 1293. Using Group "A" materials 32Amps DP switchEach326.0326.010.0FalseNoneNoneFalseNoneFalse3260.00
233800169107Nonecode98Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate.. Is 3854 and IS 1293. 6/16Amps universal socketEach236.0236.010.0FalseNoneNoneFalseNoneFalse2360.00
233800269107Nonecode99Supplying PVC/Gi Flexible conduit pipe.. Mm dia fxing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddies at an interval of 300mm using NF screws on the either end of the pipe terminated completely. 25mmMtr81.081.050.0FalseNoneNoneFalseNoneFalse4050.00
233800369107Nonecode100Supplyin and Fixing Metal Fan Box with Round Hook.Nos117.0117.04.0FalseNoneNoneFalseNoneFalse468.00
233800469107Nonecode101Point wiring using Copper wire without switch.Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 1100V Grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2x1.5 Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose lenght in a wood/PVC round block. complete for each outlet. Short point up to 3Mtr from tapping point to out let via switchPoint285.0285.020.0FalseNoneNoneFalseNoneFalse5700.00
233800569107Nonecode102Point wiring using Copper wire without switch.Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 1100V Grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2x1.5 Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose lenght in a wood/PVC round block. complete for each outlet. Medium point above 3mtr up to 6Mtr from tapping point to out let via switchPoint394.0394.024.0FalseNoneNoneFalseNoneFalse9456.00
233800669107Nonecode103Point wiring using Copper wire without switch.Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 1100V Grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2x1.5 Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose lenght in a wood/PVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switch boxPoint570.0570.024.0FalseNoneNoneFalseNoneFalse13680.00
233800769107Nonecode104Wiring for lighting/Power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper With Low conductor resistance single core wire in open or conceanled system of wiring with specified IS-694:1990 & confirming to the attached. (P-5/I-2.3.3) GTP of GROUP-a 2.5 sqmmMtr35.035.0240.0FalseNoneNoneFalseNoneFalse8400.00
233800869107Nonecode105Wiring for lighting/Power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper With Low conductor resistance single core wire in open or conceanled system of wiring with specified IS-694:1990 & confirming to the attached.4 sqmmMtr49.049.0240.0FalseNoneNoneFalseNoneFalse11760.00
233800969107Nonecode106Extra for supplying 4mm thick white plastic plate and covering for junction boxes of size ……mm conduit using necessary machine screws. 80mmMtr12.012.030.0FalseNoneNoneFalseNoneFalse360.00
233801069107Nonecode107Supplying of ....... feet - LED PVC Square Batten ..W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greaterthan 80. Power Input: 220-240V @ 50Hz & Power factor greaterthan0.9 along with CE approved. 5 years Warranty against any manufacturing defect working under standard electrical condition LED light fighting 2'- 9/10 wEach551.0551.020.0FalseNoneNoneFalseNoneFalse11020.00
233801169107Nonecode108Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies for operation on 230 Volts, 50 Cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm)Regular modelEach2984.02984.04.0FalseNoneNoneFalseNoneFalse11936.00
233801269107Nonecode109Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete.12" Sweep (300mm)Each2969.02969.04.0FalseNoneNoneFalseNoneFalse11876.00
233801369107Nonecode110Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' cure, indicator ON/OFF, energy cross-3 with Short circuit breaking cappacity of 10K and complete wiring as required. Confirming to IEC 60898. 6-32 Amps DPEach739.0739.02.0FalseNoneNoneFalseNoneFalse1478.00
233801469107Nonecode111Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' cure, indicator ON/OFF, energy cross-3 with Short circuit breaking cappacity of 10K and complete wiring as required. Confirming to IEC 60898. 50-63Amps TNPEach1102.01102.02.0FalseNoneNoneFalseNoneFalse2204.00
233801569107Nonecode112Supplying fxing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V upto 300mA sensitvity on existing wood/panel 32-40 Amps 4 poleEach5147.05147.02.0FalseNoneNoneFalseNoneFalse10294.00
233801669107Nonecode113Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm alround with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.Each4256.04256.02.0FalseNoneNoneFalseNoneFalse8512.00
233801769107Nonecode114Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required.GI strip 25x3mmMtr82.082.08.0FalseNoneNoneFalseNoneFalse656.00
233801869107Nonecode115Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with suitable approved colour powder coated paint.18SWGSq CM0.380.3840000.0FalseNoneNoneFalseNoneFalse15200.00
233801969107Nonecode116Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic alluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary botls,nuts and washers etc., complete.100Amps 4x30x6mm Alluminium StripsMtr2465.02465.01.0FalseNoneNoneFalseNoneFalse2465.00
233802069107Nonecode117Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers.. 63AmpsEach372.0372.04.0FalseNoneNoneFalseNoneFalse1488.00
233802169107Nonecode118Supplying of 1.1 KV LT UG cable having aluminium conductor PVC insulated, extruded inner sheathed,galvanised,steel strip (except 2CX10Sq.mm wire armoured) confirming to IS-3975:1990 (No. of Strip indicated in GTP) & extruded PVC outer sheathed armoured cable with specified IS-1554 Part-1:1988 & confirming to the attached GTP of GROUP-A. 4 core 16 sqmmMtr371.0371.025.0FalseNoneNoneFalseNoneFalse9275.00
233802269107Nonecode119Providing and fixing Structural Steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing inposition and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kgs106.0106.0455.0FalseNoneNoneFalseNoneFalse48230.00
233802369107Nonecode120Design, fabrication, supply, erection and commissioning of rail track using 45 kg / m standard rails for movement of gantry crane for handling tonners including cost of all materials, machinery, labour, aligning, anchoring, welding, cleaning, applying one coat of zinc rich epoxy primer and two coats of cold applied coal tar epoxy paint for buffers and rail supporting plates etc., complete as per specifications and approved drawings with all lead and all lifts including packing / forwarding charges for other materials.Mtr8700.08700.017.0FalseNoneNoneFalseNoneFalse147900.00
233802469107Nonecode121Providing, erecting triple spur gear type Chain Pulley Block suitable for capacity as below with 6 m lift complete with load chain and hand chain suitable for above lift, tested to 50% over load as per IS 3832 carrying ISI mark. -do- 3 Tonne Capacity.Each23326.023326.01.0FalseNoneNoneFalseNoneFalse23326.00
233802569107Nonecode122Providing, erecting Traveling Trolley of capacity as below with 6 m lift, tested to 50% over load. -do- 3 Tonne Capacity.Each15652.015652.01.0FalseNoneNoneFalseNoneFalse15652.00
233802669107Nonecode123Providing and constructing size stone pitching using 200 to 250 mm size stones with pin headers at 2 per m2 set in CM 1 : 5 proportion by volume with pointing joints in CM 1 : 3 proportion by volume including cost of all materials from approved source, labour, packing stone chips and mortar into joints,finishing,curing and all other ancillary operations complete. Note: If 150 mm thick murum bed is to be provided below pitching, add 93/ m2Sqm1157.11157.11125.0FalseNoneNoneFalseNoneFalse1301737.50
233802769107Nonecode124Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. Depth upto 1.5m All kinds of soils.Cum107.1107.192.28FalseNoneNoneFalseNoneFalse9883.1880
233802869107Nonecode125Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In Ordinary rock witout blasting depth exceeding 1.5m but not exceeding 3mCum381.15381.1516.29FalseNoneNoneFalseNoneFalse6208.93350
233802969107Nonecode126Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. Depth 1.5 m to 3m All kinds of soilsCum107.1107.195.98FalseNoneNoneFalseNoneFalse10279.4580
233803069107Nonecode127Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. Depth 1.5 m to 3m In Ordinary rock witout blasting depth exceeding 1.5m but not exceeding 3mCum446.25446.2551.68FalseNoneNoneFalseNoneFalse23062.20
233803169107Nonecode128Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work.Depth 3 m to 4.5m All kinds of soils.Mtr122.85122.8548.86FalseNoneNoneFalseNoneFalse6002.4510
233803269107Nonecode129Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work.In Ordinary rock witout blasting depth exceeding 3 m but not 4.5mMtr486.15486.1548.86FalseNoneNoneFalseNoneFalse23753.2890
233803369107Nonecode130Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregatesCum6555.156555.158.92FalseNoneNoneFalseNoneFalse58471.9380
233803469107Nonecode131Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6808.046808.045.67FalseNoneNoneFalseNoneFalse38601.58680
233803569107Nonecode132Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesMtr9362.599362.5930.91FalseNoneNoneFalseNoneFalse289397.65690
233803669107Nonecode133Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregate For roof slabCum10402.8810402.885.67FalseNoneNoneFalseNoneFalse58984.32960
233803769107Nonecode134Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregate For beamCum10402.8810402.881.07FalseNoneNoneFalseNoneFalse11131.08160
233803869107Nonecode135Providing and fixing MS inspection door of size 60 cms x 60 cms, including MS frame made of 50x50x6mm angle, shutters made of 3mm thick MS sheets, with hinges, locking arrangements at top etc. including painting with anticorrosive approved paint etc. complete including all lead and lifts etcEach2247.02247.01.0FalseNoneNoneFalseNoneFalse2247.00
233803969107Nonecode136Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.: Staging upto 6 m heightMT82961.5582961.554.33FalseNoneNoneFalseNoneFalse359223.51150
233804069107Nonecode137Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 mCum279.3279.3353.95FalseNoneNoneFalseNoneFalse98858.2350
233804169107Nonecode138Supply, errection, electrification and commissioning of 2 Nos. of 150 HP Non clog submersible sewage pumpsetsfor pumping sewage SUITABLE HP NON-CLOG SEWAGE PUMPSETS, PUMPSETS: Supply and delivery at site brand new approved makes sludge submersible pump coupled to approved make squirrel cage induction motor of suitable HP 'F' class insulation for the specified discharge and head mentioned below. The pumpset should operate in full range of discharge and should have the following accessories specified in the following detailed specification. the submersible sewage pump shall be monoblock type with non-clong design.DISCHAGE Q = 750CUM/HR (208.33LPS) HEAD = 46M , PUMP CASING, IMPELLER,PUMP SHAFT, PUMP BEARING, GUIDE RAIL SYSTEM,Moistor sensor(seal moistor), MECHANICAL SEAL,LIFTING CHAIN, DUCK FOOT BEND, PROFILE GASKET (Dismantling joint), SUBMERSIBLE MOTOR CABLE, FASTENERS, 01 Nos of 150 HP OR Suitable HP 69.44 LPS against 46 Mtr. Head MOTOR: The submersible motor shall be dry, squirrel cage type suitable for 3 phase, 50 cycles, 415 volts AC supply,3000 Rpm complete confirming to ISS:325/1976 shall be of such capacity to provide under working site condition at power which is 10% more than the maximum power required by the pump. Continuous duty with class 'F' insulation. Winding of the motor shall be impregnated by resin. Motor shall have integral cable entry port better starting torque characteristics. The enclosure for motor shall be IP-68. Each phase of the motor provided with thermic switches of Bi-metalic electro-mechanical temperature detectors. The motor shall operate satisfactorily at all operating levels in wetwell. The motor shall be sealed against entry of liquid being pumped by using two mechanical seals. Motor pump should have the following in built protection connections. (Please refer the attachment for detailed Specifications)Nos3015000.03015000.01.0FalseNoneNoneFalseNoneFalse3015000.00
233804269107Nonecode139CONTROL SWITCH GEAR PANELS -CONTROL SWITCH GEAR PANELS (Total Run 2 nos 150 HP Has to Run) Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. ( Icu = Ics), 700-800 A 50 kANos52395.052395.01.0FalseNoneNoneFalseNoneFalse52395.00
233804369107Nonecode140Supplying and fixing of Shunt trip suitable for MCCB.CBCTNos1788.151788.151.0FalseNoneNoneFalseNoneFalse1788.150
233804469107Nonecode141Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 Amps SPNos435.75435.7532.0FalseNoneNoneFalseNoneFalse13944.00
233804569107Nonecode142Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel boardNos9717.759717.751.0FalseNoneNoneFalseNoneFalse9717.750
233804669107Nonecode143Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracyNos9780.759780.751.0FalseNoneNoneFalseNoneFalse9780.750
233804769107Nonecode144Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape WoundNos590.1590.11.0FalseNoneNoneFalseNoneFalse590.10
233804869107Nonecode145Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.CNos540.75540.7527.0FalseNoneNoneFalseNoneFalse14600.250
233804969107Nonecode146Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 600 A 4 x 75 x 10 mm Aluminium StripsMtr5906.255906.2512.0FalseNoneNoneFalseNoneFalse70875.00
233805069107Nonecode147Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 1000 A double run of 4 x 60 x 10 mm Aluminium StripsMtr11109.011109.018.0FalseNoneNoneFalseNoneFalse199962.00
233805169107Nonecode148Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint 40*40*6mmMtr320.25320.2524.0FalseNoneNoneFalseNoneFalse7686.00
233805269107Nonecode149Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint 50x50x6mmMtr414.75414.7524.0FalseNoneNoneFalseNoneFalse9954.00
233805369107Nonecode150Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint 75 x 75 x 6 mmMtr582.75582.7532.0FalseNoneNoneFalseNoneFalse18648.00
233805469107Nonecode151Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint 50X100X50X6mm C channelMtr793.8793.824.0FalseNoneNoneFalseNoneFalse19051.20
233805569107Nonecode152Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint 75 x 150 x 75 x 6 mm C channelMtr972.3972.318.0FalseNoneNoneFalseNoneFalse17501.40
233805669107Nonecode153Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete14SWGSq CM0.530.53425000.0FalseNoneNoneFalseNoneFalse225250.00
233805769107Nonecode154Auxiliary relay/contactor for control circuitNos2334.152334.151.0FalseNoneNoneFalseNoneFalse2334.150
233805869107Nonecode155Supplying of on load change over switches 4/3 poles, AC- 23A Duty, 415V, 50Hz, AC Supply. (Open Execution)125 ANos10842.310842.35.0FalseNoneNoneFalseNoneFalse54211.50
233805969107Nonecode156Supplying of on load change over switches 4/3 poles, AC- 23A Duty, 415V, 50Hz, AC Supply. (Open Execution)630 ANos37580.5537580.552.0FalseNoneNoneFalseNoneFalse75161.10
233806069107Nonecode157Supplying of on load change over switches 4/3 poles, AC- 23A Duty, 415V, 50Hz, AC Supply. (Open Execution)800 ANos51114.051114.01.0FalseNoneNoneFalseNoneFalse51114.00
233806169107Nonecode158Supplying and fixing HRC fuse link on existing switch fuse base with W loss as per IS-13703.Above 63 A to 200 ANos400.05400.0515.0FalseNoneNoneFalseNoneFalse6000.750
233806269107Nonecode159Supplying and fixing HRC fuse link on existing switch fuse base with W loss as per IS-13703.Above 425 A to 630 ANos1205.41205.49.0FalseNoneNoneFalseNoneFalse10848.60
233806369107Nonecode160Supplying of TPST with rewirable porcelain channels in SM enclosure. Made out of 14 SWG powder coated paint of approved colour.32ANos1786.051786.052.0FalseNoneNoneFalseNoneFalse3572.10
233806469107Nonecode161Supply and fixing of Multifunctional three phase monitoring relays suitable to monitor three phase mains. It monitors all phase parameters such as over/undervoltage, phase unbalance, phase failure as well as an interrupted neutral. The corresponding threshold values are adjustable. Phase sequence monitoring as well as an ON or OFF tripping delay are selectable. The tripping delay is adjustable over a range of instantaneous to 30 s (0, 0.1-30 s). voltage rating 180V - 280V ACNos18128.2518128.251.0FalseNoneNoneFalseNoneFalse18128.250
233806569107Nonecode162Automatic Power factor control panel Supplying and fixing Moulded Case Circuit Breaker(MCCB) over the existing wood/panel board using necessary screws,bolts,nuts,necessary phase separators,handle and wiring complete.Protection of Over load and Short circuit with adjustable thermal magnetic release,Microprocessor release shall have Earth Fault as per IS/IEC60947 2.(Icu=100%lcs).In 4P MCCB,all Poles should have protection for Short Cicrcuit / Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non Priority loads must be available in the MCCB.MCCB shall be provided with double insulation(insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open)Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.160 A 25 kANos14119.3514119.351.0FalseNoneNoneFalseNoneFalse14119.350
233806669107Nonecode163Supplying and fixing of Shunt trip suitable for MCCB.CBCTNos1788.151788.151.0FalseNoneNoneFalseNoneFalse1788.150
233806769107Nonecode164Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 Amps SPNos435.75435.7516.0FalseNoneNoneFalseNoneFalse6972.00
233806869107Nonecode165Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.50-63 Amps TPNNos3242.43242.45.0FalseNoneNoneFalseNoneFalse16212.00
233806969107Nonecode166Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel boardNos9717.759717.751.0FalseNoneNoneFalseNoneFalse9717.750
233807069107Nonecode167Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracyNos9780.759780.751.0FalseNoneNoneFalseNoneFalse9780.750
233807169107Nonecode168Supplying, fixing and wiring 50/5 to 400/5A 5VA burden Current Transformer Class 0.5 accuracy with Tape WoundNos590.1590.13.0FalseNoneNoneFalseNoneFalse1770.30
233807269107Nonecode169Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.CNos540.75540.7516.0FalseNoneNoneFalseNoneFalse8652.00
233807369107Nonecode170Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete.250Amps 4x30x10mm Aluminium StripsMtr3606.753606.758.0FalseNoneNoneFalseNoneFalse28854.00
233807469107Nonecode171Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.40*40*6mmMtr320.25320.2512.0FalseNoneNoneFalseNoneFalse3843.00
233807569107Nonecode172Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.50x50x6mmMtr414.75414.7512.0FalseNoneNoneFalseNoneFalse4977.00
233807669107Nonecode173Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.50X100X50X6mm C channeMtr793.8793.824.0FalseNoneNoneFalseNoneFalse19051.20
233807769107Nonecode174Supplying and fixing of 3 pole power contactor with NO/NC contacts on existing wood/panel boaard using necessary bolts,nuts, washers and wiring etc., completee with ac-3 rating and as per IS-13947 60AmpsNos6247.56247.55.0FalseNoneNoneFalseNoneFalse31237.50
233807869107Nonecode175Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 V grade, for power factor improvement of rotating machineries likeinduction motorKvar504.0504.050.0FalseNoneNoneFalseNoneFalse25200.00
233807969107Nonecode176Supplying, fixing and wiring Automatic Power Factor controller circuit unit fully, static units controlled by 14 stage microprocessor operation, relays LED display, self programming function for power stages and operating logic checking facility for healthy and efficient of each individual capacitor bank, measurement of network harmonics with indication when limit values are exceeded, Comprehensive displays with large, three phase LED display, Long term memory for settings, protection for over voltage, power factor correction fault and no voltage, to connect/ disconnect banks, with automatic recognition or with standard programsNos22722.022722.01.0FalseNoneNoneFalseNoneFalse22722.00
233808069107Nonecode177Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete.14SWGSq CM0.530.5395000.0FalseNoneNoneFalseNoneFalse50350.00
233808169107Nonecode178Supply and fixing of Auxiliary contactor relay with 2 NO and 2 NC contact and operating coil voltage of 220V to 260V. fixed on existing wood/panel board using necessary bolts, nuts, washers and wiring etcEach1396.51396.51.0FalseNoneNoneFalseNoneFalse1396.50
233808269107Nonecode179Power Capacitors: Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 V grade, for power factor improvement of rotating machineries likeinduction motor UG CABLESKvar504.0504.0354.0FalseNoneNoneFalseNoneFalse178416.00
233808369107Nonecode180Main side cable:- Supply of 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975. 240 Sqmm, 3.5 Core, (30 GI Strips - 4 x 0.8 mm)Km905799.3905799.30.05FalseNoneNoneFalseNoneFalse45289.9650
233808469107Nonecode181Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff.120 to 240 SqmmKm33891.933891.90.05FalseNoneNoneFalseNoneFalse1694.5950
233808569107Nonecode182Load side cable:- (load side) Supply of 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975. 240 Sqmm, 3.5 Core, (30 GI Strips - 4 x 0.8 mm)Km905799.3905799.30.04FalseNoneNoneFalseNoneFalse36231.9720
233808669107Nonecode183Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff.120 to 240 SqmmKm33891.933891.90.04FalseNoneNoneFalseNoneFalse1355.6760
233808769107Nonecode1841.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975.50 Sqmm, 3.5 Core, (16 GI Strips - 4 x 0.8 mm)Km187921.65187921.650.02FalseNoneNoneFalseNoneFalse3758.4330
233808869107Nonecode1851.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975.95 Sqmm, 3.5 Core, (21 GI Strips - 4 x 0.8 mm)Km391875.75391875.750.02FalseNoneNoneFalseNoneFalse7837.5150
233808969107Nonecode186Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff.35 to 95 SqmmKm32695.9532695.950.04FalseNoneNoneFalseNoneFalse1307.8380
233809069107Nonecode18716 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm)Km148934.1148934.10.03FalseNoneNoneFalseNoneFalse4468.0230
233809169107Nonecode18825 Sqmm, 4 Core, (13 GI Strips - 4 x 0.8 mm)Km188836.2188836.20.02FalseNoneNoneFalseNoneFalse3776.7240
233809269107Nonecode189Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff.2.5 to 25 SqmmKm21930.321930.30.05FalseNoneNoneFalseNoneFalse1096.5150
233809369107Nonecode190Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990.4C x 1.5 mm2m98.798.710.0FalseNoneNoneFalseNoneFalse987.00
233809469107Nonecode191Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990.8C x 1.5 mm2m165.9165.915.0FalseNoneNoneFalseNoneFalse2488.50
233809569107Nonecode19211 KV HT XLPE CABLE:supply of 11 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975.120 Sqmm, (57 GI Wires - 2.5 mm Dia)Km1180204.21180204.20.05FalseNoneNoneFalseNoneFalse59010.210
233809669107Nonecode193Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff3x95 to 150 SqmmKm64388.164388.10.05FalseNoneNoneFalseNoneFalse3219.4050
233809769107Nonecode194ERECTION OF CAPACITORS: Foundation worksNos7875.07875.02.0FalseNoneNoneFalseNoneFalse15750.00
233809869107Nonecode195Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. 1 to 1.5 mtrCum254.1254.115.75FalseNoneNoneFalseNoneFalse4002.0750
233809969107Nonecode196Providing and laying in position plain cement concrete for levelling course for all works in foundation. The ranite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, form work, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates for PCCCum6288.456288.452.37FalseNoneNoneFalseNoneFalse14903.62650
233810069107Nonecode197Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing, form work, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - for footing (Consider 3% as form work charges for other type of foundation)Cum6652.86652.81.51FalseNoneNoneFalseNoneFalse10045.7280
233810169107Nonecode198Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, form work, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Consider 35% as form work charges for Concrete walls)Cum6804.06804.012.1FalseNoneNoneFalseNoneFalse82328.40
233810269107Nonecode199Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)MT93929.8593929.851.09FalseNoneNoneFalseNoneFalse102383.53650
233810369107Nonecode200Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-chargeSqm253.05253.0560.48FalseNoneNoneFalseNoneFalse15304.4640
233810469107Nonecode201LAYING IN G.I. PIPE: supply and laying of MS Pipe 200 mm Dia with collarMtr1009.051009.0530.0FalseNoneNoneFalseNoneFalse30271.50
233810569107Nonecode202Cable Terminations: supply and fixing of Compression type Aluminium Tubular in Line Connector for Aluminum Conductor16 SqmmNos3.153.1548.0FalseNoneNoneFalseNoneFalse151.20
233810669107Nonecode203supply and fixing of Compression type Aluminium Tubular in Line Connector for Aluminum Conductor25 SqmmNos3.153.1548.0FalseNoneNoneFalseNoneFalse151.20
233810769107Nonecode204supply and fixing of Compression type Aluminium Tubular in Line Connector for Aluminum Conductor50 SqmmNos7.357.3548.0FalseNoneNoneFalseNoneFalse352.80
233810869107Nonecode205supply and fixing of Compression type Aluminium Tubular in Line Connector for Aluminum Conductor 95 SqmmNos12.612.648.0FalseNoneNoneFalseNoneFalse604.80
233810969107Nonecode206supply and fixing of Compression type Aluminium Tubular in Line Connector for Aluminum Conductor 240 SqmmNos55.6555.6580.0FalseNoneNoneFalseNoneFalse4452.00
233811069107Nonecode207EARTHING: Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40 mm dia 2.9 mm thick 2.5m long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400 mm with a cast iron cover. The earth electrode shall have staggered holes of 12 mm dia and the electrode should be covered 150 mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nutsNos4468.84468.820.0FalseNoneNoneFalseNoneFalse89376.00
233811169107Nonecode208Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. GI strip GI Strip. 50 x 6 mm GI stripMtr228.9228.9100.0FalseNoneNoneFalseNoneFalse22890.00
233811269107Nonecode209Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. GI strip Copper strip. 25x3mmMtr598.5598.530.0FalseNoneNoneFalseNoneFalse17955.00
233811369107Nonecode210Manufacturing, providing, trasporting, rolling, lowering, laying, jointing and commissioning of ERW (Electric Resistance Welded)/ SAW (Submerged Arc Welded) MS pipes of Outer dia (Fe-410 grade) conforming to IS 3589-2001 with latest amendments, including perfect linking and welding of joints to correct position, cost of the pipes, conveyance, lead, lift charges, cost of all labour and giving satisfactory hydraulic test as per IS 3589-2001 with latest amendments for test pressure and working pressure both at factory and site etc. complete as per detailed specifications inside with CM 1:1.5 lining of minimum 10mm thick for pipes upto 610mm OD and with minimum 12mm thick beyond 610mm OD and out side with minimum 25mm thick coating in CM 1:3 over 50 x 50mm weld mesh of 13 gauge, including loading and unloading of pipes for the following diameters and specified thickness of plate as noted below, including bailing out of water wherever necessary. (Contractor will make his own arrangements for procuring water for testing). For MS Pipes of 406mm dia Note: a) No Negative tolerance in respect of thickness is pemissible. b) Basic Cost of MS Plate is considered as Rs.71,700/- per MT c) The pipe costs are FOR destination anywhere in Karnataka Pipe of 406mm dia-6.4mm thickRmtr8657.258657.2513.0FalseNoneNoneFalseNoneFalse112544.250
233811469107Nonecode211Manufacturing, providing, transporting, rolling, lowering, laying, jointing & testing and commissioning of MS specials of minimum 8mm thick such as bends, tail pieces, reduces etc. conforming to IS-7322:1985 with latest amendments and including perfect linking and welding of joints to correct position includng cost and conveyance of materials with all lead and lifts, cost all labour and giving satisfactory hydraulic test as per IS:3589:2001 with latest amendments for test pressure and working pressure both at factory and site etc. complete as per detailed specifications with inside lining two coat of food grade epoxy painting of approved make with each coat of 250 micron thick (after dry) over one coat of food grade epoxy primer of approved make with minium of 50 micron thick (after dry) and outside 25mm thick coating in CM 1:3 by providing 50x50mm weld mesh including loading and unloading of the pipes for the following category to suit PSC / MS / CI / AC / DI / PVC pipes. The weight of MS shell only by considered before lining and coating for arriving at the rate. The thickness of plate will be specified by the engineer. (Contractor will make his own arrangements for procuring water for testing) DO-for Bends, Tail Pieces, reducers, Test gaps, TEES- Upto & Inclusive of 500mm dia pipe.Fire Fighting Equipment and safty equipmentKgs178.5178.5100.0FalseNoneNoneFalseNoneFalse17850.00
233811569107Nonecode212C02 Gas aluminium body Squeeze grip Fire Extinugisher, Used Unused Mechanism, Squeeze Grip, Gross Weight 5.16 Kg. empty Weight 3.16Kg. Can Height 615M M Diameter 111MM, Discharge Time less than 8 Sees, Controllable discharge mechanism, Applicable on Class 8&C Fire, 8 Rating 138, Can Constuction: Cold Impact Extrusion, Valve Construction : Forging & Machining, Internal Coating of Can : Not Applicable, External coating of Can : Spray Painting, Aluminium metal ISO & PESO Approved, 3 Year Warranty. including cost cost of supporting materials like MS stand & accessaries if it is fixing n floor / MS brackets & accessories if it is fixing on wall,, labour, usage charges of machinery complete as per specifications. completeNos4305.04305.02.0FalseNoneNoneFalseNoneFalse8610.00
233811669107Nonecode213Supplying of first aid box. CompleteeNos630.0630.01.0FalseNoneNoneFalseNoneFalse630.00
233811769107Nonecode214Supplying of FIRST AID CHART with lamination. CompleteNos420.0420.01.0FalseNoneNoneFalseNoneFalse420.00
233811869107Nonecode215Supplying and installation of RUBBER MAT 1mtr x 1mtr -1Omm thick. complete including cost of materials, labour, usage charges of machinery complete as per specificationsNos1995.01995.01.0FalseNoneNoneFalseNoneFalse1995.00
233811969107Nonecode216Supplying of Hand gloves. CompleteNos1023.751023.751.0FalseNoneNoneFalseNoneFalse1023.750
233812069107Nonecode217Supplying of four bucket stand alongwith buckets. CompleteNo1942.51942.51.0FalseNoneNoneFalseNoneFalse1942.50
233812169107Nonecode218Providing and Fixing Fire force board size of 3'x2' made out to Acrylic sheet of 3mm thick and fixing with Stainless Steel finished studs etc. complete including cost of materials, labour, usage charges of machinery complete as per specificationsNos2625.02625.01.0FalseNoneNoneFalseNoneFalse2625.00
233812269107Nonecode219Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in ChargeKgs118.65118.651100.0FalseNoneNoneFalseNoneFalse130515.00
233812369107Nonecode220Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer in-charge. (Made of G.I. wire of dia 4 mmSqm843.15843.15150.0FalseNoneNoneFalseNoneFalse126472.50
233812469107Nonecode22111kV HT Metering cubical of different CT Ratio Both side entry type with 3CT & 3PTs with transparent cover TTB,with 30x8mm Copper Bus bars,modem and 2nos of Meters for 3 Phase 4 Wire Metering WITHOUT Load break Switch (HT Metering Box Fabricated out of 3mm MS Sheet duly epoxy powder coated)as per revised specification.Dwg No. BESCOM/GM/QS&S/--Dtd 2411.2018No255645.6255645.61.0FalseNoneNoneFalseNoneFalse255645.60
233812569107Nonecode222Load Break switches with PaneNo76900.9576900.951.0FalseNoneNoneFalseNoneFalse76900.950
233812669107Nonecode223Erection of HT metering Cubicle on PlatformNo1936.21936.21.0FalseNoneNoneFalseNoneFalse1936.20
233812769107Nonecode224Erection Alignment and fixing of Load break switch on the platformNo2181.92181.91.0FalseNoneNoneFalseNoneFalse2181.90
233812869107Nonecode225Cable End Seals:- Supply and fixing of Heat Shrinkable Indoor Type Cable Termination Kit for XLPE Cable.3x240 Sqmm.Set4925.554925.556.0FalseNoneNoneFalseNoneFalse29553.30
233812969107Nonecode226Cable End Seals:- Supply and fixing of Heat Shrinkable Outdoor Type Cable Termination Kit for XLPE Cable.3x240 SqmmSet5583.95583.92.0FalseNoneNoneFalseNoneFalse11167.80
233813069107Nonecode227CONTROL CABLE:Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990.4C x 2.5 mm2Per Mtr155.4155.4100.0FalseNoneNoneFalseNoneFalse15540.00
233813169107Nonecode228CONTROL CABLE:Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990.6C x 2.5 mm2Per Mtr285.6285.650.0FalseNoneNoneFalseNoneFalse14280.00
233813269107Nonecode2292 mm thick perforated cable GI tray with on existing MS angle support using necessary GI bolts/nuts and washer or welding as required 300 x 50 mmMtr616.35616.3550.0FalseNoneNoneFalseNoneFalse30817.50
233813369107Nonecode230Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. ( Icu = Ics)700-800 A 50 kANo52395.052395.05.0FalseNoneNoneFalseNoneFalse261975.00
233813469107Nonecode231Supplying and fixing of Shunt trip suitable for MCCB.CBCTNo1788.151788.151.0FalseNoneNoneFalseNoneFalse1788.150
233813569107Nonecode232Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 Amps SPNo435.75435.7524.0FalseNoneNoneFalseNoneFalse10458.00
233813669107Nonecode233Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel boardNo9717.759717.751.0FalseNoneNoneFalseNoneFalse9717.750
233813769107Nonecode234Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracyNo9780.759780.751.0FalseNoneNoneFalseNoneFalse9780.750
233813869107Nonecode235Supplying, fixing and wiring 1000/5A to 1600/5A 15VA Burden class 1 Current TransformerNo882.0882.01.0FalseNoneNoneFalseNoneFalse882.00
233813969107Nonecode236Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.CNo540.75540.7524.0FalseNoneNoneFalseNoneFalse12978.00
233814069107Nonecode237Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 1000 A double run of 4 x 60 x 10 mm Aluminium StripsMtr11109.011109.06.0FalseNoneNoneFalseNoneFalse66654.00
233814169107Nonecode238Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint50x50x6mmMtr414.75414.7512.0FalseNoneNoneFalseNoneFalse4977.00
233814269107Nonecode239Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint 75 x 75 x 6 mmMtr582.75582.7512.0FalseNoneNoneFalseNoneFalse6993.00
233814369107Nonecode240Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint 50X100X50X6mm C channelMtr793.8793.812.0FalseNoneNoneFalseNoneFalse9525.60
233814469107Nonecode241Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint 75 x 150 x 75 x 6 mm C channelMtr972.3972.312.0FalseNoneNoneFalseNoneFalse11667.60
233814569107Nonecode242Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., completeSq CM0.530.53295000.0FalseNoneNoneFalseNoneFalse156350.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17066029030000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17066029030000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17066029030001NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of KPP Portal on or before the last date and time of bid submission.None
17066029290000NoneNoneELIGIBILITYThe bidder is required to ensure browser compatibility of the computer well in advance to the last date and time for receipt of tenders. The departments shall not be responsible for non-accessibility of KPP portal due to internet connectivity issues and technical glitches at bidders end.None
17066029340000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17066029370000NoneNoneELIGIBILITYConditional tenders will not be accepted.None
17066029410000NoneNoneELIGIBILITYThe tenderer shall bear all costs associated with the preparation and submission of the tender and the employer will in no case be responsible and liable for those costs.None
17066029440000NoneNoneELIGIBILITYThe cost of the Tender Processing fee shall not be refundableNone
17066029480000NoneNoneELIGIBILITYThe authority reserves the rights to Reject or accept any or all the tenders without assigning any reasonsNone
17066029520000NoneNoneELIGIBILITYThe intending contractors are requested to note that they should abide by the detailed instructions and conditions contained in the respective Standard Tender documents (uploaded)None
17066029560000NoneNoneELIGIBILITYThe EMD will be released only after the Work OrderNone
17066029600000NoneNoneELIGIBILITYTenderer in his name should have in the last five years i.e. (2018-19 to 2022-23), Achieved in at least two financial years an annual financial turnover (in all classes of civil engineering construction works only) 100% of Estimate cost.None
17066029630000NoneNoneELIGIBILITYThe successful Tenderer shall deliver to the Employer a Security deposit at the time of Agreement, in the name of the Executive Engineer, Ws & UGD East Division, MCC, Mysore for an amount equivalent to 5% of the Contract price plus additional security for the difference cost (below Estimate Cost) in accordance with the Conditions of Contract.None
17066029680000NoneNoneELIGIBILITYAny dispute regarding this tender appeal should be submitted through KPP PortalNone
17066029720000NoneNoneELIGIBILITYAny changes/modifications if any will be notified/ updated through KPP Portal only.None
17066029800000NoneNoneELIGIBILITYAs per PWD Code 251. Jurisdiction: Contractors registered under Class I and II may tender for works anywhere in the state. Contractors registered under Class III may tender for works within the districts of the Public Works Department circles where in they are registered. Contractors registered under Class IV may tender for works within the district or within the division whichever is applicable, where they are registered. These registrations are valid for all works undertaken by all the Government departments, Government undertakings in the respective jurisdictions. No separate registration is required in other Government departments and Government undertakings. This registration procedure is based on the single window concept.None
17066029850000NoneNoneELIGIBILITYPayment for the work is done under 15th finance commission grant. Bidder should accept the payment procedures as prescribed time to time by the Government.None
17066029900001NoneNoneELIGIBILITYGST will be paid separately only for applicable itemsNone
17066030000000NoneNoneELIGIBILITYTenderer in his name should have in the last five years i.e. (2018-19 to 2022-23), satisfactorily completed as prime contractor, at least one similar nature of work of value not less than 50% of Estimate cost.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)NoneNone
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)NoneNone
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)NoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNone3.2 To qualify for award of this contract, each tenderer in its name should have in the last five years i.e., 2018-19 to 2022-23 (b) Satisfactory completed, at least one similar work of laying of DI/MS pipeline of value not less than Rs. 225 Lakhs as a prime contractor.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNone3.2 To qualify for award of this contract, each tenderer in its name should have in the last five years i.e., 2018-19 to 2022-23 c) Executed at least min quantities of work as specified below for continuous period of 12 months during last 5 financial years 1. DI/MS pipeline - 2400 Mtr 2. Valves 15 NosPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNone3.3 Each tenderer should further demonstrate: a) availability by owning at least 50% of the required key and critical equipment for this work and the remaining 50% can be deployed on lease /hire basis for all works provided, the relevant documents (Applicants shall produce any of these documents of the equipments-RC issued by R.T.O. /Sale deed/ purchase invoice, hire/lease agreements) shall be furnished. 1. Excavator - 2 No (Minimum 1 Own) 2. Tipper 1 No (Own/Hire) 3. Crane 1 No (Own/Hire) 4. Water tanker 2 No (Minimum 1 Own) 5. Pin vibrator 2 No (Minimum 1 Own) 6. Welding machine 1 No (Own/Hire) 7. Concrete Mixer 1 No (Own/Hire)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Vehicle and Machinery documents
NoneNoneNoneNone3.2 To qualify for award of this contract, each tenderer in its name should have in the last five years i.e., 2018-19 to 2022-23 (a) Achieved in at least two financial years a minimum annual financial turnover of Rs. 900 LakhsFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNone3.3 Each tenderer should further demonstrate: b) liquid assets and or availability of credit facilities of not less than Rs.135.00 Lakhs (Credit lines/ letters of credit/ certificates from banks for meeting the fund requirement etc. (Unconditional Line of Credit)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover Certificate with UDINTrueTechnical Bid
PWD Registration CertificateTrueTechnical Bid
Similar Nature Work Done CertificateTrueTechnical Bid
Line of CreditTrueTechnical Bid
Machinery and Vehicles documentsTrueTechnical Bid
Works in handTrueTechnical Bid
All other documents specified in bid documentTrueTechnical Bid
Quantities workdone certificate as specified in bid documentTrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1706612867000
version0
createdDateNone
modifiedDateNone
blockNumberOffice of the executive engineer Water Supply and UGD (EAST) Division, VVWW Premises, Yadavagiri, Mysore
streetNone
cityMysore
stateKarnataka
pin570020
tenderRecallDTONone