tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1706507526000 | 1 | None | None | Buildings | PRIMARY SCHOOL GROUND FLOOR | 4553966.42 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2321206 | 68585 | None | Vol 1 P-8 1.12 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth ---- Work Should be carried out in site as per Engineer incharge | Cum | 95.0 | 95.0 | 81.92 | False | None | None | False | None | False | 7782.4 | 0 | 2321207 | 68585 | None | Vol 1 P-8 1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m ---- Work Should be carried out in site as per Engineer incharge | Cum | 102.0 | 102.0 | 249.32 | False | None | None | False | None | False | 25430.64 | 0 | 2321208 | 68585 | None | Vol 1 P-8 1.15.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In ordinary/soft rock without blasting Depth upto 1.5 m depth ---- Work Should be carried out in site as per Engineer incharge | Cum | 363.0 | 363.0 | 62.33 | False | None | None | False | None | False | 22625.79 | 0 | 2321209 | 68585 | None | Vol 1 P-7 1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m ---- Work Should be carried out in site as per Engineer incharge | Cum | 266.0 | 266.0 | 249.32 | False | None | None | False | None | False | 66319.12 | 0 | 2321210 | 68585 | None | Vol 1 P-7 1.8 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. ---- Work Should be carried out in site as per Engineer incharge | Cum | 474.0 | 474.0 | 160.37 | False | None | None | False | None | False | 76015.38 | 0 | 2321211 | 68585 | None | Vol 1 P-18 2.10.a | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction ofthe Engineer-in-charge. RMC M10 Grade ---- Work Should be carried out in site as per Engineer incharge | Cum | 5866.0 | 5866.0 | 36.59 | False | None | None | False | None | False | 214636.94 | 0 | 2321212 | 68585 | None | Vol 1 P-18 2.10.c | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade. Isolated Footing ---- Work Should be carried out in site as per Engineer incharge | Cum | 6219.0 | 6219.0 | 35.53 | False | None | None | False | None | False | 220961.07 | 0 | 2321213 | 68585 | None | Vol 1 P-111 1.a | Formwork, Centering & Scaffloding 8% For Isolated Footing ---- Work Should be carried out in site as per Engineer incharge | Cum | 497.52 | 497.52 | 35.53 | False | None | None | False | None | False | 17676.8856 | 0 | 2321214 | 68585 | None | Vol 1 P-18 2.10.c | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade. Columns up to plinth ---- Work Should be carried out in site as per Engineer incharge | Cum | 6219.0 | 6219.0 | 4.2 | False | None | None | False | None | False | 26119.8 | 0 | 2321215 | 68585 | None | Vol 1 P-111 9 | Formwork, Centering & Scaffloding 70% For Columns up to plinth ---- Work Should be carried out in site as per Engineer incharge | Cum | 4353.3 | 4353.3 | 4.2 | False | None | None | False | None | False | 18283.86 | 0 | 2321216 | 68585 | None | Vol 1 P-18 2.10.c | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade. Columns ---- Work Should be carried out in site as per Engineer incharge | Cum | 6219.0 | 6219.0 | 9.08 | False | None | None | False | None | False | 56468.52 | 0 | 2321217 | 68585 | None | Vol 1 P-111 9 | Formwork, Centering & Scaffloding 70% For Columns ---- Work Should be carried out in site as per Engineer incharge | Cum | 4353.3 | 4353.3 | 9.08 | False | None | None | False | None | False | 39527.964 | 0 | 2321218 | 68585 | None | Vol 1 P-18 2.10.c | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade. Plinth Beams ---- Work Should be carried out in site as per Engineer incharge | Cum | 6219.0 | 6219.0 | 14.17 | False | None | None | False | None | False | 88123.23 | 0 | 2321219 | 68585 | None | Vol 1 P-111 2 | Formwork, Centering & Scaffloding 50% For Plinth Beams ---- Work Should be carried out in site as per Engineer incharge | Cum | 3109.5 | 3109.5 | 14.17 | False | None | None | False | None | False | 44061.615 | 0 | 2321220 | 68585 | None | Vol 1 P-18 2.10.c | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade. Beams and Lintel ---- Work Should be carried out in site as per Engineer incharge | Cum | 6219.0 | 6219.0 | 17.5 | False | None | None | False | None | False | 108832.5 | 0 | 2321221 | 68585 | None | Vol 1 P-112 14 | Formwork, Centering & Scaffloding 60% For Beams & Lintels ---- Work Should be carried out in site as per Engineer incharge | Cum | 3731.4 | 3731.4 | 17.5 | False | None | None | False | None | False | 65299.5 | 0 | 2321222 | 68585 | None | Vol 1 P-18 2.10.c | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade. Roof Slab & Staircase ---- Work Should be carried out in site as per Engineer incharge | Cum | 6219.0 | 6219.0 | 36.81 | False | None | None | False | None | False | 228921.39 | 0 | 2321223 | 68585 | None | Vol 1 P-112 15 | Formwork, Centering & Scaffloding 50% For Roof Slab & Staircase ---- Work Should be carried out in site as per Engineer incharge | Cum | 3109.5 | 3109.5 | 36.81 | False | None | None | False | None | False | 114460.695 | 0 | 2321224 | 68585 | None | Vol 1 P-18 2.10.c | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade. Sill ---- Work Should be carried out in site as per Engineer incharge | Cum | 6219.0 | 6219.0 | 1.51 | False | None | None | False | None | False | 9390.69 | 0 | 2321225 | 68585 | None | Vol 1 P-111 1b. | Formwork, Centering & Scaffloding 3% For Sill ---- Work Should be carried out in site as per Engineer incharge | Cum | 186.57 | 186.57 | 1.51 | False | None | None | False | None | False | 281.7207 | 0 | 2321226 | 68585 | None | Vol 2 P-18 2.10.c | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade. Chejja ---- Work Should be carried out in site as per Engineer incharge | Cum | 6219.0 | 6219.0 | 0.81 | False | None | None | False | None | False | 5037.39 | 0 | 2321227 | 68585 | None | Vol 2 P-112 19 | Formwork, Centering & Scaffloding 45% For Chejja ---- Work Should be carried out in site as per Engineer incharge | Cum | 2798.55 | 2798.55 | 0.81 | False | None | None | False | None | False | 2266.8255 | 0 | 2321228 | 68585 | None | Vol 2 P-18 2.11.a | Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings ---- Work Should be carried out in site as per Engineer incharge | Tonne | 89457.0 | 89457.0 | 10.73 | False | None | None | False | None | False | 959873.61 | 0 | 2321229 | 68585 | None | Vol 2 P-9 5.4 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) ---- Work Should be carried out in site as per Engineer incharge | Cum | 6389.0 | 6389.0 | 5.63 | False | None | None | False | None | False | 35970.07 | 0 | 2321230 | 68585 | None | Vol 2 P-9 5.1.1 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) ---- Work Should be carried out in site as per Engineer incharge | Cum | 5611.0 | 5611.0 | 38.58 | False | None | None | False | None | False | 216472.38 | 0 | 2321231 | 68585 | None | Vol 2 P-17 6.32 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- Work Should be carried out in site as per Engineer incharge | Sqm | 1310.0 | 1310.0 | 237.67 | False | None | None | False | None | False | 311347.7 | 0 | 2321232 | 68585 | None | Vol 2 P-17 6.34 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- Work Should be carried out in site as per Engineer incharge | Sqm | 1104.0 | 1104.0 | 15.16 | False | None | None | False | None | False | 16736.64 | 0 | 2321233 | 68585 | None | Vol 2 P-77 11.5.2 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- Work Should be carried out in site as per Engineer incharge | Sqm | 4242.0 | 4242.0 | 20.16 | False | None | None | False | None | False | 85518.72 | 0 | 2321234 | 68585 | None | Vol 2 P-86 11.34B | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. ---- Work Should be carried out in site as per Engineer incharge | Kg | 183.0 | 183.0 | 839.16 | False | None | None | False | None | False | 153566.28 | 0 | 2321235 | 68585 | None | Vol 2 P-104 12.54 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. ---- Work Should be carried out in site as per Engineer incharge | Mtr | 318.0 | 318.0 | 29.7 | False | None | None | False | None | False | 9444.6 | 0 | 2321236 | 68585 | None | Vol 2 P-104 12.55.1 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges with both side prelam ---- Work Should be carried out in site as per Engineer incharge | Sqm | 2366.0 | 2366.0 | 9.45 | False | None | None | False | None | False | 22358.7 | 0 | 2321237 | 68585 | None | Vol 2 P-41 8.1.2 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- Work Should be carried out in site as per Engineer incharge | Sqm | 241.0 | 241.0 | 419.83 | False | None | None | False | None | False | 101179.03 | 0 | 2321238 | 68585 | None | Vol 2 P-50 8.51 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- Work Should be carried out in site as per Engineer incharge | Sqm | 100.0 | 100.0 | 767.02 | False | None | None | False | None | False | 76702.0 | 0 | 2321239 | 68585 | None | Vol 2 P-41 8.2.2 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- Work Should be carried out in site as per Engineer incharge | Sqm | 279.0 | 279.0 | 322.08 | False | None | None | False | None | False | 89860.32 | 0 | 2321240 | 68585 | None | Vol 2 P-61 9.17.2 | Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm ---- Work Should be carried out in site as per Engineer incharge | Sqm | 1175.0 | 1175.0 | 156.56 | False | None | None | False | None | False | 183958.0 | 0 | 2321241 | 68585 | None | Vol 2 P-59 9.2 | Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per direction of Engineer incharge. ---- Work Should be carried out in site as per Engineer incharge | Sqm | 800.0 | 800.0 | 24.42 | False | None | None | False | None | False | 19536.0 | 0 | 2321242 | 68585 | None | Vol 2 P-64 9.31 | Providing and laying Polished Sadarahalli Grey Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 20 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ---- Work Should be carried out in site as per Engineer incharge | Sqm | 2085.0 | 2085.0 | 140.61 | False | None | None | False | None | False | 293171.85 | 0 | 2321243 | 68585 | None | Vol 2 P-60 9.11 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. ---- Work Should be carried out in site as per Engineer incharge | Sqm | 889.0 | 889.0 | 12.47 | False | None | None | False | None | False | 11085.83 | 0 | 2321244 | 68585 | None | Vol 2 P-71 10.14 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. ---- Work Should be carried out in site as per Engineer incharge | Sqm | 1106.0 | 1106.0 | 25.46 | False | None | None | False | None | False | 28158.76 | 0 | 2321245 | 68585 | None | Vol 2 P-69 10.1.1 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. ---- Work Should be carried out in site as per Engineer incharge | Sqm | 4006.0 | 4006.0 | 0.72 | False | None | None | False | None | False | 2884.32 | 0 | 2321246 | 68585 | None | Vol 2 P-84 11.25.2 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- Work Should be carried out in site as per Engineer incharge | Kg | 136.0 | 136.0 | 183.87 | False | None | None | False | None | False | 25006.32 | 0 | 2321247 | 68585 | None | Vol 2 P-46 8.33.1 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- Work Should be carried out in site as per Engineer incharge | Sqm | 158.0 | 158.0 | 767.02 | False | None | None | False | None | False | 121189.16 | 0 | 2321248 | 68585 | None | Vol 2 P-46 8.30 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- Work Should be carried out in site as per Engineer incharge | Sqm | 174.0 | 174.0 | 341.79 | False | None | None | False | None | False | 59471.46 | 0 | 2321249 | 68585 | None | Vol 2 P-47 8.36.1 | Finishing with Epoxy paint (two coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Enginer-in-charge. ---- Work Should be carried out in site as per Engineer incharge | Sqm | 176.0 | 176.0 | 47.52 | False | None | None | False | None | False | 8363.52 | 0 | 2321250 | 68585 | None | Vol 2 P-110 12.90 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC (Matching to RAL-9016) sections and with minimum TiO2 (Titanium Dioxide) at 6PHR with TPE ( Thermo Plastic Elastomer) and lead free, gaskets grey color having isolated drainage and reinforced with Galvanized Iron profile through out the window frame. The outer frame having an overall size of 108mm width x 45 mm height with reinforcement of 1mm thickness and Sash with overall size of 39 mm x 75 mm with GI reinforcement of 2mm and mesh sash of size 37 mm x 58 mm. Coextruded Glazing bead for fixing of glass shall be of size 20 mm x 24 mm. Windows shall be provided with 6 mm plain float glass, standard hardware & Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2 mm-2.5 mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T & P s shall not be made) ---- Work Should be carried out in site as per Engineer incharge | Sqm | 6734.0 | 6734.0 | 27.36 | False | None | None | False | None | False | 184242.24 | 0 | 2321251 | 68585 | None | Vol 2 P-55 8.84 | Providing wall black boards in 12mm thick with CM 1:3 and applied with primer & two coats of acrylic emulsion black paint including finishing etc.,complete. ---- Work Should be carried out in site as per Engineer incharge | Sqm | 475.0 | 475.0 | 23.04 | False | None | None | False | None | False | 10944.0 | 0 | 2321252 | 68585 | None | Vol 2 P-44 8.16a | Providing lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20 cms. c to c both horizontally and vertically fixed with chicken mesh for drop chajja,facia, backing to cup boards including cost of all materials, labour, providing and removing form work usage charges, curing, complete as per specifications. ---- Work Should be carried out in site as per Engineer incharge | Sqm | 1238.0 | 1238.0 | 19.71 | False | None | None | False | None | False | 24400.98 | 0 | 2321253 | 68585 | None | Vol 5 P-247 21.1.2 | Water purification plants: Supplying, Installation and Commissioning of automatic Water purification plant (RO+UF) with all accessories piping, product water tank on single phase power supply as per the enclosed detailed Technical Specifications including cost of material, loading and unloading and as directed by the Engineer in charge. (Ref- detailedspecification enclosed seperatly). Note:- 1. The above rates mentioned are only for the preparation of estimate purpose. 2. All items are to be of BSI/NFS standards, with BSI / NFS mark. 3. Tenders to be invited for procurement. 4. No direct payment Page should be made under any situation or condition or on any account. 5. After commissioning of plant necessary testing to be done for the satisfactory of Engineer Incharge. Note: Refer the ANNEXURE: F for Detailed Specification of Each components For 50 LPH: Cabin Type ---- Work Should be carried out in site as per Engineer incharge | Each | 44000.0 | 44000.0 | 1.0 | False | None | None | False | None | False | 44000.0 | 0 |
| 1706507527000 | 0 | None | None | Buildings | PRIMARY SCHOOL TERRACE FLOOR | 450065.22 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2321254 | 68586 | None | Vol 1 P-18 2.10.c | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade. Columns ---- Work Should be carried out in site as per Engineer incharge | Cum | 6281.19 | 6281.19 | 2.91 | False | None | None | False | None | False | 18278.2629 | 0 | 2321255 | 68586 | None | Vol 1 P-111 9 | Formwork, Centering & Scaffloding 70% For Columns ---- Work Should be carried out in site as per Engineer incharge | Cum | 4396.83 | 4396.83 | 2.91 | False | None | None | False | None | False | 12794.7753 | 0 | 2321256 | 68586 | None | Vol 1 P-18 2.10.c | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade. Beams ---- Work Should be carried out in site as per Engineer incharge | Cum | 6281.19 | 6281.19 | 1.28 | False | None | None | False | None | False | 8039.9232 | 0 | 2321257 | 68586 | None | Vol 1 P-112 14 | Formwork, Centering & Scaffloding 60% For Beams ---- Work Should be carried out in site as per Engineer incharge | Cum | 3768.71 | 3768.71 | 1.28 | False | None | None | False | None | False | 4823.9488 | 0 | 2321258 | 68586 | None | Vol 1 P-18 2.10.c | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade. Roof Slab ---- Work Should be carried out in site as per Engineer incharge | Cum | 6281.19 | 6281.19 | 2.06 | False | None | None | False | None | False | 12939.2514 | 0 | 2321259 | 68586 | None | Vol 1 P-112 15 | Formwork, Centering & Scaffloding 50% For Roof Slab ---- Work Should be carried out in site as per Engineer incharge | Cum | 3140.6 | 3140.6 | 2.06 | False | None | None | False | None | False | 6469.636 | 0 | 2321260 | 68586 | None | Vol 1 P-18 2.10.c | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade. Lintel ---- Work Should be carried out in site as per Engineer incharge | Cum | 6281.19 | 6281.19 | 0.5 | False | None | None | False | None | False | 3140.595 | 0 | 2321261 | 68586 | None | Vol 1 P-112 14 | Formwork, Centering & Scaffloding 60% For Lintel ---- Work Should be carried out in site as per Engineer incharge | Cum | 3768.71 | 3768.71 | 0.5 | False | None | None | False | None | False | 1884.355 | 0 | 2321262 | 68586 | None | Vol 1 P-18 2.10.c | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade. Sill ---- Work Should be carried out in site as per Engineer incharge | Cum | 6281.19 | 6281.19 | 0.3 | False | None | None | False | None | False | 1884.357 | 0 | 2321263 | 68586 | None | Vol 1 P-111 1b. | Formwork, Centering & Scaffloding 3% For Sill ---- Work Should be carried out in site as per Engineer incharge | Cum | 188.44 | 188.44 | 0.3 | False | None | None | False | None | False | 56.532 | 0 | 2321264 | 68586 | None | Vol 1 P-18 2.10.c | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade. Chejja ---- Work Should be carried out in site as per Engineer incharge | Cum | 6281.19 | 6281.19 | 0.12 | False | None | None | False | None | False | 753.7428 | 0 | 2321265 | 68586 | None | Vol 1 P-112 19 | Formwork, Centering & Scaffloding 45% For Chejja ---- Work Should be carried out in site as per Engineer incharge | Cum | 2826.54 | 2826.54 | 0.12 | False | None | None | False | None | False | 339.1848 | 0 | 2321266 | 68586 | None | Vol 1 P-18 2.11.a | Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings ---- Work Should be carried out in site as per Engineer incharge | Tonne | 90351.57 | 90351.57 | 1.0 | False | None | None | False | None | False | 90351.57 | 0 | 2321267 | 68586 | None | Vol 2 P-17 6.32 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- Work Should be carried out in site as per Engineer incharge | Sqm | 1323.1 | 1323.1 | 32.12 | False | None | None | False | None | False | 42497.972 | 0 | 2321268 | 68586 | None | Vol 2 P-17 6.34 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- Work Should be carried out in site as per Engineer incharge | Sqm | 1115.04 | 1115.04 | 49.44 | False | None | None | False | None | False | 55127.5776 | 0 | 2321269 | 68586 | None | Vol 2 P-86 11.34B | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. ---- Work Should be carried out in site as per Engineer incharge | Kg | 184.83 | 184.83 | 45.36 | False | None | None | False | None | False | 8383.8888 | 0 | 2321270 | 68586 | None | Vol 2 P-77 11.5.2 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge ---- Work Should be carried out in site as per Engineer incharge | Sqm | 4284.42 | 4284.42 | 2.52 | False | None | None | False | None | False | 10796.7384 | 0 | 2321271 | 68586 | None | Vol 2 P-41 8.1.2 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- Work Should be carried out in site as per Engineer incharge | Sqm | 243.41 | 243.41 | 43.26 | False | None | None | False | None | False | 10529.9166 | 0 | 2321272 | 68586 | None | Vol 2 50 8.51 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- Work Should be carried out in site as per Engineer incharge | Sqm | 101.0 | 101.0 | 68.31 | False | None | None | False | None | False | 6899.31 | 0 | 2321273 | 68586 | None | Vol 2 P-41 8.2.1 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- Work Should be carried out in site as per Engineer incharge | Sqm | 297.95 | 297.95 | 210.02 | False | None | None | False | None | False | 62575.459 | 0 | 2321274 | 68586 | None | Vol 2 P-46 8.33.1 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- Work Should be carried out in site as per Engineer incharge | Sqm | 159.58 | 159.58 | 68.31 | False | None | None | False | None | False | 10900.9098 | 0 | 2321275 | 68586 | None | Vol 2 P-46 8.30 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- Work Should be carried out in site as per Engineer incharge | Sqm | 175.74 | 175.74 | 210.02 | False | None | None | False | None | False | 36908.9148 | 0 | 2321276 | 68586 | None | Vol 2 P-47 8.36.1 | Finishing with Epoxy paint (two coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Enginer-in-charge. ---- Work Should be carried out in site as per Engineer incharge | Sqm | 177.76 | 177.76 | 4.68 | False | None | None | False | None | False | 831.9168 | 0 | 2321277 | 68586 | None | Vol 2 P-21 7.1.1 | Providing & fixing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete as per design drawings (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required as per the direction of Engineer in charge. ---- Work Should be carried out in site as per Engineer incharge | Sqm | 887.79 | 887.79 | 19.84 | False | None | None | False | None | False | 17613.7536 | 0 | 2321278 | 68586 | None | Vol 2 P-77 11.1 | Providing and fixing Structural Steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- Work Should be carried out in site as per Engineer incharge | Kg | 107.06 | 107.06 | 98.56 | False | None | None | False | None | False | 10551.8336 | 0 | 2321279 | 68586 | None | Vol-2 P-110 12.90 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile through out the window frame. The outer frame
having an overall size of 108mm width x 45 mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded
Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- Work Should be carried out in site as per Engineer incharge | Sqm | 6801.34 | 6801.34 | 2.16 | False | None | None | False | None | False | 14690.8944 | 0 |
| 1706507527000 | 0 | None | None | Buildings | PRIMARY SCHOOL SANITARY AND WATER SUPPLY | 363098.0 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2321280 | 68587 | None | Vol 2 P-117 13.3.1 | Providing and fixing brass stop cock of approved quality :15 mm nominal bore ---- Work Should be carried out in site as per Engineer incharge | Nos | 299.0 | 299.0 | 8.0 | False | None | None | False | None | False | 2392.0 | 0 | 2321281 | 68587 | None | Vol 2 P-120 13.20.2 | Providing and fixing PTMT pillar cock of approved quality and colour. 15 mm nominal bore, 125 mm long foam flow, weighing not less than 120 gms ---- Work Should be carried out in site as per Engineer incharge | Nos | 314.0 | 314.0 | 4.0 | False | None | None | False | None | False | 1256.0 | 0 | 2321282 | 68587 | None | Vol 2 P-131 14.1.1 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests ---- Work Should be carried out in site as per Engineer incharge | Nos | 4884.0 | 4884.0 | 3.0 | False | None | None | False | None | False | 14652.0 | 0 | 2321283 | 68587 | None | Vol 2 P-131 14.2.1 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlleddevice (handle lever), conforming to IS : 7231, with all fittings andfixtures complete, including cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid ---- Work Should be carried out in site as per Engineer incharge | Nos | 4838.0 | 4838.0 | 1.0 | False | None | None | False | None | False | 4838.0 | 0 | 2321284 | 68587 | None | Vol 2 P-135 14.23 | Providing and fixing white vitreous china flat back or wall corner type
lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes
respectively. ---- Work Should be carried out in site as per Engineer incharge | Nos | 1154.0 | 1154.0 | 1.0 | False | None | None | False | None | False | 1154.0 | 0 | 2321285 | 68587 | None | Vol 2 P-133 14.7.8 | White Vitreous China Surgeon type wash basin of size 660x460 mm with a pair of 15 mm C.P. brass pillar taps with elbow including operated levers ---- Work Should be carried out in site as per Engineer incharge | Nos | 4113.0 | 4113.0 | 4.0 | False | None | None | False | None | False | 16452.0 | 0 | 2321286 | 68587 | None | Vol 2 P-133 14.8 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. ---- Work Should be carried out in site as per Engineer incharge | Nos | 1423.0 | 1423.0 | 4.0 | False | None | None | False | None | False | 5692.0 | 0 | 2321287 | 68587 | None | Vol 2 P-137 14.40.2 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g ---- Work Should be carried out in site as per Engineer incharge | Nos | 496.0 | 496.0 | 2.0 | False | None | None | False | None | False | 992.0 | 0 | 2321288 | 68587 | None | Vol 2 P-136 14.32.2 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 453x357 mm ---- Work Should be carried out in site as per Engineer incharge | Nos | 1018.0 | 1018.0 | 4.0 | False | None | None | False | None | False | 4072.0 | 0 | 2321289 | 68587 | None | Vol 2 P-122 13.31.2 | Providing & fixing Chorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction Engineer in Charge.Exposed on wall - 20mm nominal dia pipes ---- Work Should be carried out in site as per Engineer incharge | Mtr | 242.0 | 242.0 | 20.0 | False | None | None | False | None | False | 4840.0 | 0 | 2321290 | 68587 | None | Vol 2 P-122 13.31.3 | Providing & fixing Chorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction Engineer in Charge.Exposed on wall - 25mm nominal dia pipes ---- Work Should be carried out in site as per Engineer incharge | Mtr | 318.0 | 318.0 | 20.0 | False | None | None | False | None | False | 6360.0 | 0 | 2321291 | 68587 | None | Vol 2 P-122 13.31.4 | Providing & fixing Chorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction Engineer in Charge.Exposed on wall - 32mm nominal dia pipes ---- Work Should be carried out in site as per Engineer incharge | Mtr | 400.0 | 400.0 | 75.0 | False | None | None | False | None | False | 30000.0 | 0 | 2321292 | 68587 | None | Vol 2 P-122 13.31.6 | Providing & fixing Chorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction Engineer in Charge.Exposed on wall - 50mm nominal dia pipes ---- Work Should be carried out in site as per Engineer incharge | Mtr | 781.0 | 781.0 | 60.0 | False | None | None | False | None | False | 46860.0 | 0 | 2321293 | 68587 | None | Vol 2 P-117 13.4.4 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :50 mm nominal bore ---- Work Should be carried out in site as per Engineer incharge | Nos | 855.0 | 855.0 | 15.0 | False | None | None | False | None | False | 12825.0 | 0 | 2321294 | 68587 | None | Vol 2 P-118 13.8.2.2 | Providing and fixing unplasticised PVC connection pipe with brass unions :45 cm length 20 mm nominal bore ---- Work Should be carried out in site as per Engineer incharge | Nos | 110.0 | 110.0 | 15.0 | False | None | None | False | None | False | 1650.0 | 0 | 2321295 | 68587 | None | Vol 2 P-123 13.34 | Providing and placing on terrace, polyethylene water storage tanks as per IS 12701 : 1996 with manhole lid and suitable locking arrangements, making holes of suitable diameter for inlet, outlet and over flow pipes but without fittings and the base support for tank ---- Work Should be carried out in site as per Engineer incharge | Ltr | 9.0 | 9.0 | 4000.0 | False | None | None | False | None | False | 36000.0 | 0 | 2321296 | 68587 | None | Vol 5 P-A-44 660 | PVC pipes of 8 Kg/cm2 for 140mm(3.097) ---- Work Should be carried out in site as per Engineer incharge | Mtr | 456.0 | 456.0 | 111.5 | False | None | None | False | None | False | 50844.0 | 0 | 2321297 | 68587 | None | Vol 5 P-A-44 664 | PVC pipes of 10 Kg/cm2 for 200mm ---- Work Should be carried out in site as per Engineer incharge | Mtr | 1155.0 | 1155.0 | 30.0 | False | None | None | False | None | False | 34650.0 | 0 | 2321298 | 68587 | None | Vol 2 P-125 13.49 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes of 150mm dia conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes ---- Work Should be carried out in site as per Engineer incharge | Mtr | 568.0 | 568.0 | 21.5 | False | None | None | False | None | False | 12212.0 | 0 | 2321299 | 68587 | None | Vol 5 P-208 16.60.1 | Providing PVC-U INDIVIDUAL U.G.D House service connection (which shall be laid from inside the customer property ) which includes: a) Supply of PVC-U pipe (b) providing and fixing of 315 mm dia the PE Inspection chambres with lid consisting of inlet & outlet arrangements with base, riser of min. 0.42 m depth which includes earth work, fixing in CC-1:2:4 with appurtenances., complete. (c) civil works like Earthwork excavation for the pipeline trenches for laying of PVC-U pipes for the house connections in all types of soils , disintegrated rock,soft rock, hard rock, including cutting of any road using , crossing drains, compound, Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, c.c. wood work, steel work, including T & P and scaffolding wherever necessary sorting the dismantled material, disposal of unserviceable and stacking the serviceable material with all lifts and lead , restoring the damaged portions inside or outside the property premises, refilling the portions of trenches that are dug open including linking to existing sewer network with appurtenances. complete. 110 mm dia ---- Work Should be carried out in site as per Engineer incharge | Each | 8134.0 | 8134.0 | 2.0 | False | None | None | False | None | False | 16268.0 | 0 | 2321300 | 68587 | None | Vol 1 5 1.4.1 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m ---- Work Should be carried out in site as per Engineer incharge | Cum | 242.0 | 242.0 | 9.0 | False | None | None | False | None | False | 2178.0 | 0 | 2321301 | 68587 | None | Vol 1 7 1.90 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m ---- Work Should be carried out in site as per Engineer incharge | Cum | 266.0 | 266.0 | 20.0 | False | None | None | False | None | False | 5320.0 | 0 | 2321302 | 68587 | None | Vol 5 191 16.90 | Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover ---- Work Should be carried out in site as per Engineer incharge | Each | 5454.0 | 5454.0 | 4.0 | False | None | None | False | None | False | 21816.0 | 0 | 2321303 | 68587 | None | Vol 5 192 16.15.1 | Providing and constructing “WIRE CUT BRICK MACHINEHOLE CHAMBERS” using Portland/Pozzolana cement, conical in shape at top, with CC 1:3:6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15M alround the chamber. Construct Brick masonry in CM 1:4, 340 mm thick, with wirecut bricks of approved quality, plaster inside and out side with CM 1:3, 12mm thick, except for the conical surface outside where the plaster thickness shall be 20mm. Slope inside to be 1:6 in the concrete towards central drain and finished smooth. Fixing of pipes in CC 1:2:4 with graded metal of 20mm and down size. Supplying and fixing SFRC Machinehole frame and cover (Heavy Duty) conforming to IS:12592 with latest amendment, in CC 1:2:4. Supplying and fixing footsteps made of 12mm dia. steel bars (Fe-500) with 3mm thick plastic encapsulation (IS-10910). The footsteps shall be fixed 30cms apart and on CC block embeded to masonry wall. The whole works include watering, curing, barricading, danger lighting, pouring tar over MH frame and cover, cost of tar, shoring, strutting, dewatering, engraving Machinehole number with flow direction on the inner conical surface etc. as per the drawing etc. as per technical specifications and for the following diameters and depth etc. for 1.2mm diaCirc. B M.HConstructing Brick Masonry Circular Machinehole 1.2 m internal dia. , 1.0 M depth & SFRC cover & frame ---- Work Should be carried out in site as per Engineer incharge | Each | 29047.0 | 29047.0 | 1.0 | False | None | None | False | None | False | 29047.0 | 0 | 2321304 | 68587 | None | Vol 2 135 14.29 | Providing and fixing 100 mm sand cast Iron grating for gully trap. ---- Work Should be carried out in site as per Engineer incharge | Each | 47.0 | 47.0 | 8.0 | False | None | None | False | None | False | 376.0 | 0 | 2321305 | 68587 | None | Vol 2 120 13.22.1.2 | Providing and fixing PTMT grating of approved quality and colour 125 mm nominal dia ---- Work Should be carried out in site as per Engineer incharge | No | 44.0 | 44.0 | 8.0 | False | None | None | False | None | False | 352.0 | 0 |
| 1706507527000 | 0 | None | None | Buildings | PRIMARY SCHOOL Electrification | 223242.6 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2321306 | 68588 | None | 1.2.1 (2 of 105) | Concealed Conduit System :Supplying heavy gauge PVC conduit pipe mm dia mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary19/20mm dia 2mm thick (PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Mtr | 66.0 | 66.0 | 150.0 | False | None | None | False | None | False | 9900.0 | 0 | 2321307 | 68588 | None | 1.2.2 (2 of 105) | Concealed Conduit System :Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary25mm dia 2mm thick.(PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Mtr | 78.0 | 78.0 | 150.0 | False | None | None | False | None | False | 11700.0 | 0 | 2321308 | 68588 | None | 1.3.1 (2 of 105) | Supplying heavy gauge PVC Conduit Pipe 25dia 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.19/20mm dia 2mm thick.(PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Mtr | 68.0 | 68.0 | 25.0 | False | None | None | False | None | False | 1700.0 | 0 | 2321309 | 68588 | None | 1.3.2 (2 of 105) | Supplying heavy gauge PVC Conduit Pipe 25dia 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.25mm dia 2mm thick.(PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Mtr | 79.0 | 79.0 | 25.0 | False | None | None | False | None | False | 1975.0 | 0 | 2321310 | 68588 | None | 1.9.2 (3 of 105) | Supplying PVC/GI flexible conduit pipe .... mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of the pipe terminated completely25mm.(PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Mtr | 22.0 | 22.0 | 10.0 | False | None | None | False | None | False | 220.0 | 0 | 2321311 | 68588 | None | 2.1.1 (5 of 105) | Point wiring using Copper wire with out switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm (Phase&Neutral) &1x1.0 Sqmm(earth Wire)Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto3mtr from tapping point to out let via Switch.(PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Point | 285.0 | 285.0 | 8.0 | False | None | None | False | None | False | 2280.0 | 0 | 2321312 | 68588 | None | 2.1.2 (5 of 105) | Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch.(PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Point | 394.0 | 394.0 | 23.0 | False | None | None | False | None | False | 9062.0 | 0 | 2321313 | 68588 | None | 2.1.3 (5 of 105) | Long point above 6Mtr upto 10Mtr from tapping point to out let via switch box.(PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Point | 570.0 | 570.0 | 4.0 | False | None | None | False | None | False | 2280.0 | 0 | 2321314 | 68588 | None | 2.3.2 (5 of 105) | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade,1.5 SQMM multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP.(PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Mtr | 26.0 | 26.0 | 150.0 | False | None | None | False | None | False | 3900.0 | 0 | 2321315 | 68588 | None | 2.3.3 (5 of 105) | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade,2.5 SQMM multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP.(PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Mtr | 42.0 | 42.0 | 300.0 | False | None | None | False | None | False | 12600.0 | 0 | 2321316 | 68588 | None | 3.4.2 (8 of 105) | Supplying and flush mounting powder coated / galvanized metal box size 1-3way suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall.(PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Each | 159.0 | 159.0 | 3.0 | False | None | None | False | None | False | 477.0 | 0 | 2321317 | 68588 | None | 3.4.3 (8 of 105) | Supplying and flush mounting powder coated / galvanized metal box size 4-5way suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall.(PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Each | 177.0 | 177.0 | 4.0 | False | None | None | False | None | False | 708.0 | 0 | 2321318 | 68588 | None | 3.4.5 (8 of 105) | Supplying and flush mounting powder coated / galvanized metal box size 8way suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall.(PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Each | 261.0 | 261.0 | 4.0 | False | None | None | False | None | False | 1044.0 | 0 | 2321319 | 68588 | None | 3.4.6 (8 of 105) | Supplying and flush mounting powder coated / galvanized metal box size 10-12way suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall.(PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Each | 319.0 | 319.0 | 8.0 | False | None | None | False | None | False | 2552.0 | 0 | 2321320 | 68588 | None | 3.5.2 (8 of 105) | Supplying and fixing superior quality 3Mudular modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal box.(PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Each | 161.0 | 161.0 | 3.0 | False | None | None | False | None | False | 483.0 | 0 | 2321321 | 68588 | None | 3.5.3 (8 of 105) | Supplying and fixing superior quality 4Mudular modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal box.(PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Each | 175.0 | 175.0 | 4.0 | False | None | None | False | None | False | 700.0 | 0 | 2321322 | 68588 | None | 3.5.5 (8 of 105) | Supplying and fixing superior quality 8 modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalbox.(PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Each | 284.0 | 284.0 | 4.0 | False | None | None | False | None | False | 1136.0 | 0 | 2321323 | 68588 | None | 3.5.6 (8 of 105) | Supplying and fixing superior quality 10-12Mudular modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalbox.(PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Each | 344.0 | 344.0 | 8.0 | False | None | None | False | None | False | 2752.0 | 0 | 2321324 | 68588 | None | 3.6.1 (9 of 105) | Supplying and fixing of 6Amps 0ne way modular switch on existing modular switch plate as per IS 3854 and IS 1293.(PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Each | 102.0 | 102.0 | 50.0 | False | None | None | False | None | False | 5100.0 | 0 | 2321325 | 68588 | None | 3.6.3 (9 of 105) | Supplying and fixing of 6Amps 3way modular Socketc on existing modular switch plate as per IS 3854 and IS 1293.(PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Each | 171.0 | 171.0 | 15.0 | False | None | None | False | None | False | 2565.0 | 0 | 2321326 | 68588 | None | 3.6.4 (9 of 105) | Supplying and fixing of modular stepped fan regulator Two Module on existing modular switch plate as per and IS 1293.(PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Each | 357.0 | 357.0 | 8.0 | False | None | None | False | None | False | 2856.0 | 0 | 2321327 | 68588 | None | 3.14.6 (10 of 105) | Supplying and fixing of 6AmpsLamp holder on existing board.(PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | No | 71.0 | 71.0 | 35.0 | False | None | None | False | None | False | 2485.0 | 0 | 2321328 | 68588 | None | 5.7.3 (14 of 105) | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers.63amps.(PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Each | 401.0 | 401.0 | 3.0 | False | None | None | False | None | False | 1203.0 | 0 | 2321329 | 68588 | None | 5.18.1 (17 of 105) | Supplying and fixingof 6to32 Amps Single pole miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.(PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Each | 415.0 | 415.0 | 5.0 | False | None | None | False | None | False | 2075.0 | 0 | 2321330 | 68588 | None | 5.18.4 (17 of 105) | Supplying and fixingof 6to32 Amps Double pole miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.(PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Each | 739.0 | 739.0 | 1.0 | False | None | None | False | None | False | 739.0 | 0 | 2321331 | 68588 | None | 5.19.9 (18 of 105) | Supplying and fixing 12way regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure.I - doble Door12way sp&n.(PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Each | 2329.0 | 2329.0 | 1.0 | False | None | None | False | None | False | 2329.0 | 0 | 2321332 | 68588 | None | 6.3.1 (30 of 105) | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm) Economy model.(PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Each | 2984.0 | 2984.0 | 8.0 | False | None | None | False | None | False | 23872.0 | 0 | 2321333 | 68588 | None | 11.3.2 (43 of 105) | LED Indood supplying of 1x4 feet LED PVC square batten 20/22 W with high quality diffuser with life of 25000 burning hours at 70% lumen maintenance with CRI 80 power input 220-240V@ 50Hz & Power Factor 0.9 along with CE approved drivers. 2 years Warrenty againest any manufacturing defect working under standard electrical condition(PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Each | 690.0 | 690.0 | 23.0 | False | None | None | False | None | False | 15870.0 | 0 | 2321334 | 68588 | None | 11..11.4 (47 of 105) | Supplying & fixing of retrofi ttype LED bulb...... Wwith OPALacry licdiffuser comprising of LED source with CCT 6500 degreeK, CRI70%. efficacy 80lumenper W, life25000 burning hoursand Compliance to IS10322/IEC60598, LM79&LM80. The LED are driven byHFelectronicdriverintegratedinthesystem,withPF 0.95,powerlossshould 5oflampWage.,shortcircuit&opencircuitprotectiontobeintegratedinthecircuit,THDlessthan20%,LifeasperLM79.Theoperatinginputvoltageshouldbebetween130to275V.BISApprovedandTestedbyNABL/CPRIaccreditedlaboratorywith2yearsWarrantyagains tany manufacturing defect working under standard electrical condition. (PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Each | 154.0 | 154.0 | 5.0 | False | None | None | False | None | False | 770.0 | 0 | 2321335 | 68588 | None | 13.7.1 (56 of 105) | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps.(PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Each | 122.0 | 122.0 | 23.0 | False | None | None | False | None | False | 2806.0 | 0 | 2321336 | 68588 | None | 13.10 (57 of 105) | Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired.(PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Each | 171.0 | 171.0 | 8.0 | False | None | None | False | None | False | 1368.0 | 0 | 2321337 | 68588 | None | 12.56 (54 of 105) | Supplying,fixing,wiring,earthelectrodeforgroundingconduits,I.C.cutoutsandotherequipment'sonthemeterboardusing40mmdia2.90mmthickGIpipe2.5mlongburiedinapit.Thepitshouldbefilledwithequalproportionofsaltandcharcoal150mmall-roundthepipetocompletedepth.Theconnectionfromthepipetotheconduitetc.,istobeestablishedthroughGIwireofsizeasperlSIspecification7.3.3.ofIS732using12mmdiabolts,nuts,washersandchecknutsetc., the pipe shall have 16 through holes of 12 mm dia (PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | No | 3510.0 | 3510.0 | 1.0 | False | None | None | False | None | False | 3510.0 | 0 | 2321338 | 68588 | None | 32.07 (13 of 81) | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip25Sqmm, 3.5 Core, (12 GI Strips - 4 x 0.8 mm) (PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Km | 139549.0 | 139549.0 | 0.06 | False | None | None | False | None | False | 8372.94 | 0 | 2321339 | 68588 | None | 11.1.5 127 | Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990
with latest amendments complete with GI fittings (excluding the cost
of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For:Heavy Duty GI Pipe etc. complete Light Duty GI pipe of 40mm dia (Volume - 5 SR Water Supply and Sewerage Works) ---- Work Should be carried out in site as per Engineer incharge | Mtr | 412.0 | 412.0 | 10.0 | False | None | None | False | None | False | 4120.0 | 0 | 2321340 | 68588 | None | 1.4.1 5 | Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of
labour, tools & other appurtenaces required to complete the work.( PWD common SR Vol-I 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Cum | 242.0 | 242.0 | 22.0 | False | None | None | False | None | False | 5324.0 | 0 | 2321341 | 68588 | None | 1.10 7 | Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour complete as per specifications ( PWD common SR Vol-I 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Cum | 160.0 | 160.0 | 22.0 | False | None | None | False | None | False | 3520.0 | 0 | 2321342 | 68588 | None | 21.05 (52 of 81) | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 to 25 Sqmm (PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Km | 20886.0 | 20886.0 | 0.06 | False | None | None | False | None | False | 1253.16 | 0 | 2321343 | 68588 | None | 5.37 (19 of 105) | Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 V grade, for power factor improvement of rotating machineries like induction motor.(PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Kvar | 480.0 | 480.0 | 50.0 | False | None | None | False | None | False | 24000.0 | 0 | 2321344 | 68588 | None | 5.38 (19 of 105) | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz12/24V D.C (PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Each | 515.0 | 515.0 | 3.0 | False | None | None | False | None | False | 1545.0 | 0 | 2321345 | 68588 | None | 5.40.1 (20 of 105) | Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete.100 A 4 x 30 x 10 mm Aluminium Strips (PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Mtr | 2465.0 | 2465.0 | 0.5 | False | None | None | False | None | False | 1232.5 | 0 | 2321346 | 68588 | None | 5.41.2 (20 of 105) | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.50 x 50 x 6 mm (PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Mtr | 395.0 | 395.0 | 6.0 | False | None | None | False | None | False | 2370.0 | 0 | 2321347 | 68588 | None | 5.42.2 (21 of 105) | Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.16 SWG ((PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Sq CM | 0.43 | 0.43 | 50000.0 | False | None | None | False | None | False | 21500.0 | 0 | 2321348 | 68588 | None | 6.1 (30 of 105) | Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.(PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Each | 1492.0 | 1492.0 | 1.0 | False | None | None | False | None | False | 1492.0 | 0 | 2321349 | 68588 | None | 11.8.2 (46 of 105) | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 &LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LEDEfficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part.Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source..LED Streetlight 40 W (PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Each | 4024.0 | 4024.0 | 2.0 | False | None | None | False | None | False | 8048.0 | 0 | 2321350 | 68588 | None | 13.1.1 (56 of 105) | Supplying and Fixing of........mm dia class A GI pipe bracket upto 2 ms long bent at suitable angle and fixing to this bracket 1x40/2x40 W fluorescent tube street light fitting of all capacities to GI or GI or rail or RCC pole / wall using suitable clA, bolts, and nuts and wiring using suitable capacity wires.Using 25mm dia G.I.Pipe(PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Each | 978.0 | 978.0 | 2.0 | False | None | None | False | None | False | 1956.0 | 0 | 2321351 | 68588 | None | 13.14 (57 of 105) | Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire..(PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Each | 492.0 | 492.0 | 1.0 | False | None | None | False | None | False | 492.0 | 0 | 2321352 | 68588 | None | HESCOM approval | Providing TC for power supply arrangement as per HESCOM approval ---- Work Should be carried out in site as per Engineer incharge | Each | 5000.0 | 5000.0 | 1.0 | False | None | None | False | None | False | 5000.0 | 0 |
| 1706507527000 | 0 | None | None | Buildings | PRIMARY SCHOOL SEPTIC TANK | 186307.86 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2321353 | 68589 | None | Vol 1 P-8 1.12 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth ---- Work Should be carried out in site as per Engineer incharge | Cum | 95.0 | 95.0 | 3.29 | False | None | None | False | None | False | 312.55 | 0 | 2321354 | 68589 | None | Vol 1 P-8 1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m ---- Work Should be carried out in site as per Engineer incharge | Cum | 102.0 | 102.0 | 32.92 | False | None | None | False | None | False | 3357.84 | 0 | 2321355 | 68589 | None | Vol 2 P-13 6.1 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding
and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. ---- Work Should be carried out in site as per Engineer incharge | Cum | 8220.0 | 8220.0 | 9.09 | False | None | None | False | None | False | 74719.8 | 0 | 2321356 | 68589 | None | Vol 1 P-18 2.10.c | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade. Plinth Beam ---- Work Should be carried out in site as per Engineer incharge | Cum | 6219.0 | 6219.0 | 1.92 | False | None | None | False | None | False | 11940.48 | 0 | 2321357 | 68589 | None | Vol 1 P-111 1.a | Formwork, Centering & Scaffloding 50% For Plinth Beams ---- Work Should be carried out in site as per Engineer incharge | Cum | 3109.5 | 3109.5 | 1.92 | False | None | None | False | None | False | 5970.24 | 0 | 2321358 | 68589 | None | Vol 1 P-18 2.10.c | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade. for Slab ---- Work Should be carried out in site as per Engineer incharge | Cum | 6219.0 | 6219.0 | 3.01 | False | None | None | False | None | False | 18719.19 | 0 | 2321359 | 68589 | None | Vol 1 P-111 9 | Formwork, Centering & Scaffloding 50% For Slab ---- Work Should be carried out in site as per Engineer incharge | Cum | 3109.5 | 3109.5 | 3.01 | False | None | None | False | None | False | 9359.595 | 0 | 2321360 | 68589 | None | Vol 2 P-18 2.11.a | Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings ---- Work Should be carried out in site as per Engineer incharge | Tonne | 89457.0 | 89457.0 | 0.53 | False | None | None | False | None | False | 47412.21 | 0 | 2321361 | 68589 | None | Vol 2 P-41 8.1.2 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- Work Should be carried out in site as per Engineer incharge | Sqm | 241.0 | 241.0 | 43.95 | False | None | None | False | None | False | 10591.95 | 0 | 2321362 | 68589 | None | Vol 5 P-221 18.3 | Providing & fixing 455x610 mm cast iron cover with frame weight to be not less 38kgs (weight of cover 23 kgs and weight of frame 15 kgs)and necessary locking arrangements with M.S flats 32x6 mm etc & painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge. ---- Work Should be carried out in site as per Engineer incharge | Sqm | 1962.0 | 1962.0 | 2.0 | False | None | None | False | None | False | 3924.0 | 0 |
| 1706507527000 | 1 | None | None | Buildings | High School Ground Floor | 4676766.99 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2321363 | 68590 | None | Vol 1 P-8 1.12 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth ---- Work Should be carried out in site as per Engineer incharge | Cum | 95.0 | 95.0 | 97.81 | False | None | None | False | None | False | 9291.95 | 0 | 2321364 | 68590 | None | Vol 1 P-8 1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m ---- Work Should be carried out in site as per Engineer incharge | Cum | 102.0 | 102.0 | 103.01 | False | None | None | False | None | False | 10507.02 | 0 | 2321365 | 68590 | None | Vol 1 P-8 1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m ---- Work Should be carried out in site as per Engineer incharge | Cum | 102.0 | 102.0 | 189.5 | False | None | None | False | None | False | 19329.0 | 0 | 2321366 | 68590 | None | Vol 1 P-8 1.15.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In ordinary/soft rock without blasting Depth upto 1.5 m depth ---- Work Should be carried out in site as per Engineer incharge | Cum | 363.0 | 363.0 | 81.21 | False | None | None | False | None | False | 29479.23 | 0 | 2321367 | 68590 | None | Vol 1 P-7 1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m ---- Work Should be carried out in site as per Engineer incharge | Cum | 266.0 | 266.0 | 189.5 | False | None | None | False | None | False | 50407.0 | 0 | 2321368 | 68590 | None | Vol 1 P-7 1.8 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. ---- Work Should be carried out in site as per Engineer incharge | Cum | 474.0 | 474.0 | 163.65 | False | None | None | False | None | False | 77570.1 | 0 | 2321369 | 68590 | None | Vol 1 P-18 2.10.a | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M10 Grade ---- Work Should be carried out in site as per Engineer incharge | Cum | 5866.0 | 5866.0 | 38.39 | False | None | None | False | None | False | 225195.74 | 0 | 2321370 | 68590 | None | Vol 1 P-18 2.10.c | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade. Isolated Footing ---- Work Should be carried out in site as per Engineer incharge | Cum | 6219.0 | 6219.0 | 53.54 | False | None | None | False | None | False | 332965.26 | 0 | 2321371 | 68590 | None | Vol 1 P-111 1.a | Formwork, Centering & Scaffloding 8% For Isolated Footing ---- Work Should be carried out in site as per Engineer incharge | Cum | 497.52 | 497.52 | 53.54 | False | None | None | False | None | False | 26637.2208 | 0 | 2321372 | 68590 | None | Vol 1 P-18 2.10.c | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade. Columns up to plinth ---- Work Should be carried out in site as per Engineer incharge | Cum | 6219.0 | 6219.0 | 5.72 | False | None | None | False | None | False | 35572.68 | 0 | 2321373 | 68590 | None | Vol 1 P-111 9 | Formwork, Centering & Scaffloding 70% For Columns up to plinth ---- Work Should be carried out in site as per Engineer incharge | Cum | 4353.3 | 4353.3 | 5.72 | False | None | None | False | None | False | 24900.876 | 0 | 2321374 | 68590 | None | Vol 1 P-18 2.10.c | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade. Columns ---- Work Should be carried out in site as per Engineer incharge | Cum | 6219.0 | 6219.0 | 10.2 | False | None | None | False | None | False | 63433.8 | 0 | 2321375 | 68590 | None | Vol 1 P-111 9 | Formwork, Centering & Scaffloding 70% For Columns ---- Work Should be carried out in site as per Engineer incharge | Cum | 4353.3 | 4353.3 | 10.2 | False | None | None | False | None | False | 44403.66 | 0 | 2321376 | 68590 | None | Vol 1 P-18 2.10.c | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade. Plinth beams ---- Work Should be carried out in site as per Engineer incharge | Cum | 6219.0 | 6219.0 | 13.03 | False | None | None | False | None | False | 81033.57 | 0 | 2321377 | 68590 | None | Vol 1 P-111 2 | Formwork, Centering & Scaffloding 50% For Plinth Beams ---- Work Should be carried out in site as per Engineer incharge | Cum | 3109.5 | 3109.5 | 13.03 | False | None | None | False | None | False | 40516.785 | 0 | 2321378 | 68590 | None | Vol 1 P-18 2.10.c | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade. Beams ---- Work Should be carried out in site as per Engineer incharge | Cum | 6219.0 | 6219.0 | 14.16 | False | None | None | False | None | False | 88061.04 | 0 | 2321379 | 68590 | None | Vol 1 P-112 14 | Formwork, Centering & Scaffloding 60% For Beams ---- Work Should be carried out in site as per Engineer incharge | Cum | 3731.4 | 3731.4 | 14.16 | False | None | None | False | None | False | 52836.624 | 0 | 2321380 | 68590 | None | Vol 1 P-18 2.10.c | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade. Slab ---- Work Should be carried out in site as per Engineer incharge | Cum | 6219.0 | 6219.0 | 38.01 | False | None | None | False | None | False | 236384.19 | 0 | 2321381 | 68590 | None | Vol 1 P-112 15 | Formwork, Centering & Scaffloding 50% For Roof Slab & Staircase ---- Work Should be carried out in site as per Engineer incharge | Cum | 3109.5 | 3109.5 | 38.01 | False | None | None | False | None | False | 118192.095 | 0 | 2321382 | 68590 | None | Vol 1 P-18 2.10.c | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade. Lintel ---- Work Should be carried out in site as per Engineer incharge | Cum | 6219.0 | 6219.0 | 3.49 | False | None | None | False | None | False | 21704.31 | 0 | 2321383 | 68590 | None | Vol 1 P-112 14 | Formwork, Centering & Scaffloding 60% FOR Lintel ---- Work Should be carried out in site as per Engineer incharge | Cum | 3731.4 | 3731.4 | 3.49 | False | None | None | False | None | False | 13022.586 | 0 | 2321384 | 68590 | None | Vol 1 P-18 2.10.c | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade. Sill ---- Work Should be carried out in site as per Engineer incharge | Cum | 6219.0 | 6219.0 | 1.47 | False | None | None | False | None | False | 9141.93 | 0 | 2321385 | 68590 | None | Vol 1 P-111 1b. | Formwork, Centering & Scaffloding 3% For Sill ---- Work Should be carried out in site as per Engineer incharge | Cum | 186.57 | 186.57 | 1.47 | False | None | None | False | None | False | 274.2579 | 0 | 2321386 | 68590 | None | Vol 1 P-18 2.10.c | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade. Chejja ---- Work Should be carried out in site as per Engineer incharge | Cum | 6219.0 | 6219.0 | 1.242 | False | None | None | False | None | False | 7723.998 | 0 | 2321387 | 68590 | None | Vol 1 P-112 19 | Formwork, Centering & Scaffloding 45% For Chejja ---- Work Should be carried out in site as per Engineer incharge | Cum | 2798.55 | 2798.55 | 1.242 | False | None | None | False | None | False | 3475.7991 | 0 | 2321388 | 68590 | None | Vol 1 P-18 2.11.a | Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings ---- Work Should be carried out in site as per Engineer incharge | Tonne | 89457.0 | 89457.0 | 12.07 | False | None | None | False | None | False | 1079745.99 | 0 | 2321389 | 68590 | None | Vol 2 P-9 5.4 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) ---- Work Should be carried out in site as per Engineer incharge | Cum | 6389.0 | 6389.0 | 6.83 | False | None | None | False | None | False | 43636.87 | 0 | 2321390 | 68590 | None | Vol 2 P-9 5.1.1 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) ---- Work Should be carried out in site as per Engineer incharge | Cum | 5611.0 | 5611.0 | 38.75 | False | None | None | False | None | False | 217426.25 | 0 | 2321391 | 68590 | None | Vol 2 P-17 6.32 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- Work Should be carried out in site as per Engineer incharge | Sqm | 1310.0 | 1310.0 | 226.68 | False | None | None | False | None | False | 296950.8 | 0 | 2321392 | 68590 | None | Vol 2 P-17 6.34 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- Work Should be carried out in site as per Engineer incharge | Sqm | 1104.0 | 1104.0 | 22.66 | False | None | None | False | None | False | 25016.64 | 0 | 2321393 | 68590 | None | Vol 2 P-77 11.5.2 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- Work Should be carried out in site as per Engineer incharge | Sqm | 4242.0 | 4242.0 | 10.08 | False | None | None | False | None | False | 42759.36 | 0 | 2321394 | 68590 | None | Vol 2 P-86 11.34B | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. ---- Work Should be carried out in site as per Engineer incharge | Kg | 183.0 | 183.0 | 559.44 | False | None | None | False | None | False | 102377.52 | 0 | 2321395 | 68590 | None | Vol 2 P-104 12.54 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. ---- Work Should be carried out in site as per Engineer incharge | Mtr | 318.0 | 318.0 | 19.8 | False | None | None | False | None | False | 6296.4 | 0 | 2321396 | 68590 | None | Vol 2 P-104 12.55.1 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges with both side prelam ---- Work Should be carried out in site as per Engineer incharge | Sqm | 2366.0 | 2366.0 | 6.3 | False | None | None | False | None | False | 14905.8 | 0 | 2321397 | 68590 | None | Vol 2 P-110 12.88 | Providing & fixing of 2 track x 2panel sliding door made out of multi chambered UPVC (Matching to RAL 9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile through out the window frame. The outer frame having a overall size of 60 mm width x 45 mm height with reinforcement of 1 mm thickness and Sash with overall size of 39 mm X 58 mm with GI reinforcement of 1 mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 20 mm x 24 mm. Windows shall be provided with 5 mm plain float glass, standard hardware & single point locking system with touch lock. Wall thickness of frame & sash shall be of 2 2.5 mm. Maximum possible size 1819 mm x 1819mm (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- Work Should be carried out in site as per Engineer incharge | Sqm | 5390.0 | 5390.0 | 1.89 | False | None | None | False | None | False | 10187.1 | 0 | 2321398 | 68590 | None | Vol 2 P-41 8.1.2 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- Work Should be carried out in site as per Engineer incharge | Sqm | 241.0 | 241.0 | 438.95 | False | None | None | False | None | False | 105786.95 | 0 | 2321399 | 68590 | None | Vol 2 P-50 8.51 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- Work Should be carried out in site as per Engineer incharge | Sqm | 100.0 | 100.0 | 801.55 | False | None | None | False | None | False | 80155.0 | 0 | 2321400 | 68590 | None | Vol 2 P-41 8.2.2 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- Work Should be carried out in site as per Engineer incharge | Sqm | 279.0 | 279.0 | 264.83 | False | None | None | False | None | False | 73887.57 | 0 | 2321401 | 68590 | None | Vol 2 P-61 9.17.2 | Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm ---- Work Should be carried out in site as per Engineer incharge | Sqm | 1175.0 | 1175.0 | 161.34 | False | None | None | False | None | False | 189574.5 | 0 | 2321402 | 68590 | None | Vol 2 P-59 9.2 | Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per direction of Engineer incharge. ---- Work Should be carried out in site as per Engineer incharge | Sqm | 800.0 | 800.0 | 24.59 | False | None | None | False | None | False | 19672.0 | 0 | 2321403 | 68590 | None | Vol 2 P-64 9.31 | Providing and laying Polished Sadarahalli Grey Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 20 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ---- Work Should be carried out in site as per Engineer incharge | Sqm | 2085.0 | 2085.0 | 132.52 | False | None | None | False | None | False | 276304.2 | 0 | 2321404 | 68590 | None | Vol 2 P-60 9.11 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. ---- Work Should be carried out in site as per Engineer incharge | Sqm | 889.0 | 889.0 | 22.16 | False | None | None | False | None | False | 19700.24 | 0 | 2321405 | 68590 | None | Vol 2 P-71 10.14 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. ---- Work Should be carried out in site as per Engineer incharge | Sqm | 1106.0 | 1106.0 | 14.8 | False | None | None | False | None | False | 16368.8 | 0 | 2321406 | 68590 | None | Vol 2 P-69 10.1.1 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. ---- Work Should be carried out in site as per Engineer incharge | Sqm | 4006.0 | 4006.0 | 3.6 | False | None | None | False | None | False | 14421.6 | 0 | 2321407 | 68590 | None | Vol 2 P-84 11.25.2 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- Work Should be carried out in site as per Engineer incharge | Kg | 136.0 | 136.0 | 183.87 | False | None | None | False | None | False | 25006.32 | 0 | 2321408 | 68590 | None | Vol 2 P-46 8.33.1 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- Work Should be carried out in site as per Engineer incharge | Sqm | 158.0 | 158.0 | 801.55 | False | None | None | False | None | False | 126644.9 | 0 | 2321409 | 68590 | None | Vol 2 P-46 8.30 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- Work Should be carried out in site as per Engineer incharge | Sqm | 174.0 | 174.0 | 284.0 | False | None | None | False | None | False | 49416.0 | 0 | 2321410 | 68590 | None | Vol 2 P-47 8.36.1 | Finishing with Epoxy paint (two coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Enginer-in-charge. ---- Work Should be carried out in site as per Engineer incharge | Sqm | 176.0 | 176.0 | 36.72 | False | None | None | False | None | False | 6462.72 | 0 | 2321411 | 68590 | None | Vol 2 P-110 12.90 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile through out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm 2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- Work Should be carried out in site as per Engineer incharge | Sqm | 6734.0 | 6734.0 | 26.64 | False | None | None | False | None | False | 179393.76 | 0 | 2321412 | 68590 | None | Vol 2 P-55 8.84 | Providing wall black boards in 12mm thick with CM 1:3 and applied with primer & two coats of acrylic emulsion black paint including finishing etc.,complete. ---- Work Should be carried out in site as per Engineer incharge | Sqm | 475.0 | 475.0 | 17.28 | False | None | None | False | None | False | 8208.0 | 0 | 2321413 | 68590 | None | Vol 2 P-44 8.16a | Providing lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20 cms. c to c both horizontally and vertically fixed with chicken mesh for drop chajja,facia, backing to cup boards including cost of all materials, labour, providing and removing form work usage charges, curing, complete as per specifications. ---- Work Should be carried out in site as per Engineer incharge | Sqm | 1238.0 | 1238.0 | 19.71 | False | None | None | False | None | False | 24400.98 | 0 |
| 1706507527000 | 0 | None | None | Buildings | High School FIRST FLOOR | 2926008.62 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2321414 | 68591 | None | Vol 1 P-18 2.10.c | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade. Columns ---- Work Should be carried out in site as per Engineer incharge | Cum | 6281.19 | 6281.19 | 10.2 | False | None | None | False | None | False | 64068.138 | 0 | 2321415 | 68591 | None | Vol 1 P-111 9 | Formwork, Centering & Scaffloding 70% For Columns ---- Work Should be carried out in site as per Engineer incharge | Cum | 4396.84 | 4396.84 | 10.2 | False | None | None | False | None | False | 44847.768 | 0 | 2321416 | 68591 | None | Vol 1 P-18 2.10.c | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade. Beams ---- Work Should be carried out in site as per Engineer incharge | Cum | 6281.19 | 6281.19 | 14.16 | False | None | None | False | None | False | 88941.6504 | 0 | 2321417 | 68591 | None | Vol 1 P-112 14 | Formwork, Centering & Scaffloding 60% For Beams ---- Work Should be carried out in site as per Engineer incharge | Cum | 3768.72 | 3768.72 | 14.16 | False | None | None | False | None | False | 53365.0752 | 0 | 2321418 | 68591 | None | Vol 1 P-18 2.10.c | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade. Roof Slab ---- Work Should be carried out in site as per Engineer incharge | Cum | 6281.19 | 6281.19 | 35.35 | False | None | None | False | None | False | 222040.0665 | 0 | 2321419 | 68591 | None | Vol 1 P-112 15 | Formwork, Centering & Scaffloding 50% For Roof Slab ---- Work Should be carried out in site as per Engineer incharge | Cum | 3140.6 | 3140.6 | 35.35 | False | None | None | False | None | False | 111020.21 | 0 | 2321420 | 68591 | None | Vol 1 P-18 2.10.c | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade. Staircase ---- Work Should be carried out in site as per Engineer incharge | Cum | 6281.19 | 6281.19 | 2.67 | False | None | None | False | None | False | 16770.7773 | 0 | 2321421 | 68591 | None | Vol 1 P-112 15 | Formwork, Centering & Scaffloding 50% For Staircase ---- Work Should be carried out in site as per Engineer incharge | Cum | 3140.6 | 3140.6 | 2.67 | False | None | None | False | None | False | 8385.402 | 0 | 2321422 | 68591 | None | Vol 1 P-18 2.10.c | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade. Lintel ---- Work Should be carried out in site as per Engineer incharge | Cum | 6281.19 | 6281.19 | 2.99 | False | None | None | False | None | False | 18780.7581 | 0 | 2321423 | 68591 | None | Vol 1 P-112 14 | Formwork, Centering & Scaffloding 60% For Lintel ---- Work Should be carried out in site as per Engineer incharge | Cum | 3768.72 | 3768.72 | 2.99 | False | None | None | False | None | False | 11268.4728 | 0 | 2321424 | 68591 | None | Vol 1 18 2.10.c | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade. Sill ---- Work Should be carried out in site as per Engineer incharge | Cum | 6281.19 | 6281.19 | 1.33 | False | None | None | False | None | False | 8353.9827 | 0 | 2321425 | 68591 | None | Vol 1 P-111 1b. | Formwork, Centering & Scaffloding 3% For Sill ---- Work Should be carried out in site as per Engineer incharge | Cum | 188.44 | 188.44 | 1.33 | False | None | None | False | None | False | 250.6252 | 0 | 2321426 | 68591 | None | Vol 1 P-18 2.10.c | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade. Chejja ---- Work Should be carried out in site as per Engineer incharge | Cum | 6281.19 | 6281.19 | 1.01 | False | None | None | False | None | False | 6344.0019 | 0 | 2321427 | 68591 | None | Vol 1 P-112 19 | Formwork, Centering & Scaffloding 45% For Chejja ---- Work Should be carried out in site as per Engineer incharge | Cum | 2826.54 | 2826.54 | 1.01 | False | None | None | False | None | False | 2854.8054 | 0 | 2321428 | 68591 | None | Vol 1 P-18 2.11.a | Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings ---- Work Should be carried out in site as per Engineer incharge | Tonne | 90351.57 | 90351.57 | 7.42 | False | None | None | False | None | False | 670408.6494 | 0 | 2321429 | 68591 | None | Vol 2 P-17 6.32 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- Work Should be carried out in site as per Engineer incharge | Sqm | 1323.1 | 1323.1 | 261.21 | False | None | None | False | None | False | 345606.951 | 0 | 2321430 | 68591 | None | Vol 2 P-77 11.5.2 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- Work Should be carried out in site as per Engineer incharge | Sqm | 4284.42 | 4284.42 | 10.08 | False | None | None | False | None | False | 43186.9536 | 0 | 2321431 | 68591 | None | Vol 2 P-86 11.34B | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. ---- Work Should be carried out in site as per Engineer incharge | Kg | 184.83 | 184.83 | 574.56 | False | None | None | False | None | False | 106195.9248 | 0 | 2321432 | 68591 | None | Vol 2 P-41 8.1.2 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- Work Should be carried out in site as per Engineer incharge | Sqm | 243.41 | 243.41 | 361.81 | False | None | None | False | None | False | 88068.1721 | 0 | 2321433 | 68591 | None | Vol 2 P-50 8.51 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- Work Should be carried out in site as per Engineer incharge | Sqm | 101.0 | 101.0 | 724.41 | False | None | None | False | None | False | 73165.41 | 0 | 2321434 | 68591 | None | Vol 2 P-41 8.2.1 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- Work Should be carried out in site as per Engineer incharge | Sqm | 297.95 | 297.95 | 310.22 | False | None | None | False | None | False | 92430.049 | 0 | 2321435 | 68591 | None | Vol 2 P-61 9.17.2 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm ---- Work Should be carried out in site as per Engineer incharge | Sqm | 1186.75 | 1186.75 | 187.44 | False | None | None | False | None | False | 222444.42 | 0 | 2321436 | 68591 | None | Vol 2 P-64 9.31 | Providing and laying Polished Sadarahalli Grey Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 20 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ---- Work Should be carried out in site as per Engineer incharge | Sqm | 2105.85 | 2105.85 | 103.33 | False | None | None | False | None | False | 217597.4805 | 0 | 2321437 | 68591 | None | Vol 2 P-84 11.25.2 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- Work Should be carried out in site as per Engineer incharge | Kg | 137.36 | 137.36 | 106.25 | False | None | None | False | None | False | 14594.5 | 0 | 2321438 | 68591 | None | Vol 2 P-46 8.33.1 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- Work Should be carried out in site as per Engineer incharge | Sqm | 159.58 | 159.58 | 724.41 | False | None | None | False | None | False | 115601.3478 | 0 | 2321439 | 68591 | None | Vol 2 P-46 8.30 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- Work Should be carried out in site as per Engineer incharge | Sqm | 175.74 | 175.74 | 329.39 | False | None | None | False | None | False | 57886.9986 | 0 | 2321440 | 68591 | None | Vol 2 P-47 8.36.1 | Finishing with Epoxy paint (two coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Enginer-in-charge. ---- Work Should be carried out in site as per Engineer incharge | Sqm | 177.76 | 177.76 | 37.44 | False | None | None | False | None | False | 6655.3344 | 0 | 2321441 | 68591 | None | Vol 2 P-110 12.90 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile through out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm 2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- Work Should be carried out in site as per Engineer incharge | Sqm | 6801.34 | 6801.34 | 27.36 | False | None | None | False | None | False | 186084.6624 | 0 | 2321442 | 68591 | None | Vol 2 P-55 8.84 | Providing wall black boards in 12mm thick with CM 1:3 and applied with primer & two coats of acrylic emulsion black paint including finishing etc.,complete. ---- Work Should be carried out in site as per Engineer incharge | Sqm | 479.75 | 479.75 | 8.64 | False | None | None | False | None | False | 4145.04 | 0 | 2321443 | 68591 | None | Vol 2 P-44 8.16a | Providing lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20 cms. c to c both horizontally and vertically fixed with chicken mesh for drop chajja,facia, backing to cup boards including cost of all materials, labour, providing and removing form work usage charges, curing, complete as per specifications. ---- Work Should be carried out in site as per Engineer incharge | Sqm | 1250.38 | 1250.38 | 19.71 | False | None | None | False | None | False | 24644.9898 | 0 |
| 1706507527000 | 0 | None | None | Buildings | High School TERRACE FLOOR | 503333.52 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2321444 | 68592 | None | Vol 1 P-18 2.10.c | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade. Columns ---- Work Should be carried out in site as per Engineer incharge | Cum | 6343.38 | 6343.38 | 3.79 | False | None | None | False | None | False | 24041.4102 | 0 | 2321445 | 68592 | None | Vol 1 P-111 9 | Formwork, Centering & Scaffloding 70% For Columns ---- Work Should be carried out in site as per Engineer incharge | Cum | 4440.37 | 4440.37 | 3.79 | False | None | None | False | None | False | 16829.0023 | 0 | 2321446 | 68592 | None | Vol 1 P-18 2.10.c | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade. Beams ---- Work Should be carried out in site as per Engineer incharge | Cum | 6343.38 | 6343.38 | 1.51 | False | None | None | False | None | False | 9578.5038 | 0 | 2321447 | 68592 | None | Vol 1 P-112 14 | Formwork, Centering & Scaffloding 60% For Beams ---- Work Should be carried out in site as per Engineer incharge | Cum | 3806.03 | 3806.03 | 1.51 | False | None | None | False | None | False | 5747.1053 | 0 | 2321448 | 68592 | None | Vol 1 P-18 2.10.c | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade. Roof Slab ---- Work Should be carried out in site as per Engineer incharge | Cum | 6343.38 | 6343.38 | 2.25 | False | None | None | False | None | False | 14272.605 | 0 | 2321449 | 68592 | None | Vol 1 P-112 15 | Formwork, Centering & Scaffloding 50% For Roof Slab ---- Work Should be carried out in site as per Engineer incharge | Cum | 3171.69 | 3171.69 | 2.25 | False | None | None | False | None | False | 7136.3025 | 0 | 2321450 | 68592 | None | Vol 1 P-18 2.10.c | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade. Lintel ---- Work Should be carried out in site as per Engineer incharge | Cum | 6343.38 | 6343.38 | 0.53 | False | None | None | False | None | False | 3361.9914 | 0 | 2321451 | 68592 | None | Vol 1 P-112 14 | Formwork, Centering & Scaffloding 60% For Lintel ---- Work Should be carried out in site as per Engineer incharge | Cum | 3806.03 | 3806.03 | 0.53 | False | None | None | False | None | False | 2017.1959 | 0 | 2321452 | 68592 | None | Vol 1 P-18 2.10.c | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade. Sill ---- Work Should be carried out in site as per Engineer incharge | Cum | 6343.38 | 6343.38 | 0.28 | False | None | None | False | None | False | 1776.1464 | 0 | 2321453 | 68592 | None | Vol 1 P-111 1b. | Formwork, Centering & Scaffloding 3% For Sill ---- Work Should be carried out in site as per Engineer incharge | Cum | 190.3 | 190.3 | 0.28 | False | None | None | False | None | False | 53.284 | 0 | 2321454 | 68592 | None | Vol 1 P-18 2.10.c | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade. Chejja ---- Work Should be carried out in site as per Engineer incharge | Cum | 6343.38 | 6343.38 | 0.13 | False | None | None | False | None | False | 824.6394 | 0 | 2321455 | 68592 | None | Vol 1 P-112 19 | Formwork, Centering & Scaffloding 45% For Chejja ---- Work Should be carried out in site as per Engineer incharge | Cum | 2854.52 | 2854.52 | 0.13 | False | None | None | False | None | False | 371.0876 | 0 | 2321456 | 68592 | None | Vol 1 P-18 2.11.a | Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings ---- Work Should be carried out in site as per Engineer incharge | Tonne | 91246.14 | 91246.14 | 1.27 | False | None | None | False | None | False | 115882.5978 | 0 | 2321457 | 68592 | None | Vol 2 P-17 6.32 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- Work Should be carried out in site as per Engineer incharge | Sqm | 1336.2 | 1336.2 | 38.01 | False | None | None | False | None | False | 50788.962 | 0 | 2321458 | 68592 | None | Vol 2 P-17 6.34 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- Work Should be carried out in site as per Engineer incharge | Sqm | 1126.08 | 1126.08 | 49.06 | False | None | None | False | None | False | 55245.4848 | 0 | 2321459 | 68592 | None | Vol 2 P-86 11.34B | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. ---- Work Should be carried out in site as per Engineer incharge | Kg | 186.66 | 186.66 | 45.36 | False | None | None | False | None | False | 8466.8976 | 0 | 2321460 | 68592 | None | Vol 2 P-77 11.5.2 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge ---- Work Should be carried out in site as per Engineer incharge | Sqm | 4326.84 | 4326.84 | 2.52 | False | None | None | False | None | False | 10903.6368 | 0 | 2321461 | 68592 | None | Vol 2 P-41 8.1.2 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- Work Should be carried out in site as per Engineer incharge | Sqm | 245.82 | 245.82 | 46.11 | False | None | None | False | None | False | 11334.7602 | 0 | 2321462 | 68592 | None | Vol 2 P-50 8.51 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- Work Should be carried out in site as per Engineer incharge | Sqm | 102.0 | 102.0 | 73.19 | False | None | None | False | None | False | 7465.38 | 0 | 2321463 | 68592 | None | Vol 2 P-41 8.2.1 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- Work Should be carried out in site as per Engineer incharge | Sqm | 300.9 | 300.9 | 208.8 | False | None | None | False | None | False | 62827.92 | 0 | 2321464 | 68592 | None | Vol 2 P-46 8.33.1 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- Work Should be carried out in site as per Engineer incharge | Sqm | 161.16 | 161.16 | 73.19 | False | None | None | False | None | False | 11795.3004 | 0 | 2321465 | 68592 | None | Vol 2 P-46 8.30 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- Work Should be carried out in site as per Engineer incharge | Sqm | 177.48 | 177.48 | 208.8 | False | None | None | False | None | False | 37057.824 | 0 | 2321466 | 68592 | None | Vol 2 P-47 8.36.1 | Finishing with Epoxy paint (two coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Enginer-in-charge. ---- Work Should be carried out in site as per Engineer incharge | Sqm | 179.52 | 179.52 | 4.68 | False | None | None | False | None | False | 840.1536 | 0 | 2321467 | 68592 | None | Vol 2 P-21 7.1.1 | Providing & fixing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete as per design drawings (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required as per the direction of Engineer in charge. ---- Work Should be carried out in site as per Engineer incharge | Sqm | 896.58 | 896.58 | 21.44 | False | None | None | False | None | False | 19222.6752 | 0 | 2321468 | 68592 | None | Vol 2 P-77 11.1 | Providing and fixing Structural Steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- Work Should be carried out in site as per Engineer incharge | Kg | 108.12 | 108.12 | 98.56 | False | None | None | False | None | False | 10656.3072 | 0 | 2321469 | 68592 | None | Vol 2 P-110 12.90 | Providing & fixing of 3 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL 9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile through out the window frame. The outer frame having an overall size of 108mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded
Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm 2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- Work Should be carried out in site as per Engineer incharge | Sqm | 6868.68 | 6868.68 | 2.16 | False | None | None | False | None | False | 14836.3488 | 0 |
| 1706507527000 | 0 | None | None | Buildings | High School Sanitary & water supply | 471249.0 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2321470 | 68593 | None | Vol 2 P-117 13.3.1 | Providing and fixing brass stop cock of approved quality :15 mm nominal bore ---- Work Should be carried out in site as per Engineer incharge | Nos | 299.0 | 299.0 | 10.0 | False | None | None | False | None | False | 2990.0 | 0 | 2321471 | 68593 | None | Vol 2 P-120 13.20.2 | Providing and fixing PTMT pillar cock of approved quality and colour. 15 mm nominal bore, 125 mm long foam flow, weighing not less than 120 gms ---- Work Should be carried out in site as per Engineer incharge | Nos | 314.0 | 314.0 | 8.0 | False | None | None | False | None | False | 2512.0 | 0 | 2321472 | 68593 | None | Vol 2 P-131 14.1.1 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests ---- Work Should be carried out in site as per Engineer incharge | Nos | 4884.0 | 4884.0 | 2.0 | False | None | None | False | None | False | 9768.0 | 0 | 2321473 | 68593 | None | Vol 2 P-131 14.2.1 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid ---- Work Should be carried out in site as per Engineer incharge | Nos | 4838.0 | 4838.0 | 1.0 | False | None | None | False | None | False | 4838.0 | 0 | 2321474 | 68593 | None | Vol 2 P-135 14.23 | Providing and fixing white vitreous china flat back or wall corner type
lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes
respectively. ---- Work Should be carried out in site as per Engineer incharge | Nos | 1154.0 | 1154.0 | 1.0 | False | None | None | False | None | False | 1154.0 | 0 | 2321475 | 68593 | None | Vol 2 P-133 14.7.8 | White Vitreous China Surgeon type wash basin of size 660x460 mm with a pair of 15 mm C.P. brass pillar taps with elbow including operated levers ---- Work Should be carried out in site as per Engineer incharge | Nos | 4113.0 | 4113.0 | 8.0 | False | None | None | False | None | False | 32904.0 | 0 | 2321476 | 68593 | None | Vol 2 P-133 14.8 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. ---- Work Should be carried out in site as per Engineer incharge | Nos | 1423.0 | 1423.0 | 8.0 | False | None | None | False | None | False | 11384.0 | 0 | 2321477 | 68593 | None | Vol 2 P-137 14.40.2 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g ---- Work Should be carried out in site as per Engineer incharge | Each | 496.0 | 496.0 | 4.0 | False | None | None | False | None | False | 1984.0 | 0 | 2321478 | 68593 | None | Vol 2 P-136 14.32.2 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 453x357 mm ---- Work Should be carried out in site as per Engineer incharge | Nos | 1018.0 | 1018.0 | 8.0 | False | None | None | False | None | False | 8144.0 | 0 | 2321479 | 68593 | None | Vol 2 P-122 13.31.2 | Providing & fixing Chorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction Engineer in Charge.Exposed on wall - 20mm nominal dia pipes ---- Work Should be carried out in site as per Engineer incharge | Mtr | 242.0 | 242.0 | 30.0 | False | None | None | False | None | False | 7260.0 | 0 | 2321480 | 68593 | None | Vol 2 P-122 13.31.3 | Providing & fixing Chorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction Engineer in Charge.Exposed on wall - 25mm nominal dia pipes ---- Work Should be carried out in site as per Engineer incharge | Mtr | 318.0 | 318.0 | 30.0 | False | None | None | False | None | False | 9540.0 | 0 | 2321481 | 68593 | None | Vol 2 P-122 13.31.4 | Providing & fixing Chorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction Engineer in Charge.Exposed on wall - 32mm nominal dia pipes ---- Work Should be carried out in site as per Engineer incharge | Mtr | 400.0 | 400.0 | 75.0 | False | None | None | False | None | False | 30000.0 | 0 | 2321482 | 68593 | None | Vol 2 P-122 13.31.6 | Providing & fixing Chorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction Engineer in Charge.Exposed on wall - 50mm nominal dia pipes ---- Work Should be carried out in site as per Engineer incharge | Mtr | 781.0 | 781.0 | 90.0 | False | None | None | False | None | False | 70290.0 | 0 | 2321483 | 68593 | None | Vol 2 P-117 13.4.4 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :50 mm nominal bore ---- Work Should be carried out in site as per Engineer incharge | Nos | 855.0 | 855.0 | 15.0 | False | None | None | False | None | False | 12825.0 | 0 | 2321484 | 68593 | None | Vol 2 P-118 13.8.2.2 | Providing and fixing unplasticised PVC connection pipe with brass unions :45 cm length 20 mm nominal bore ---- Work Should be carried out in site as per Engineer incharge | Nos | 110.0 | 110.0 | 15.0 | False | None | None | False | None | False | 1650.0 | 0 | 2321485 | 68593 | None | Vol 2 P-123 13.34 | Providing and placing on terrace, polyethylene water storage tanks as per IS 12701 : 1996 with manhole lid and suitable locking arrangements, making holes of suitable diameter for inlet, outlet and over flow pipes but without fittings and the base support for tank ---- Work Should be carried out in site as per Engineer incharge | Ltr | 9.0 | 9.0 | 5000.0 | False | None | None | False | None | False | 45000.0 | 0 | 2321486 | 68593 | None | Vol 5 P-A-44 660 | PVC pipes of 8 Kg/cm2 for 140mm(3.097) ---- Work Should be carried out in site as per Engineer incharge | Mtr | 456.0 | 456.0 | 128.0 | False | None | None | False | None | False | 58368.0 | 0 | 2321487 | 68593 | None | Vol 5 A-44 664 | PVC pipes of 10 Kg/cm2 for 200mm ---- Work Should be carried out in site as per Engineer incharge | Mtr | 1155.0 | 1155.0 | 30.0 | False | None | None | False | None | False | 34650.0 | 0 | 2321488 | 68593 | None | Vol 2 P-125 13 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes of 150mm dia conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes ---- Work Should be carried out in site as per Engineer incharge | Mtr | 568.0 | 568.0 | 38.0 | False | None | None | False | None | False | 21584.0 | 0 | 2321489 | 68593 | None | Vol 5 P-208 16.60.1 | Providing PVC-U INDIVIDUAL U.G.D House service connection (which shall be laid from inside the customer property ) which includes: a) Supply of PVC-U pipe (b) providing and fixing of 315 mm dia the PE Inspection chambres with lid consisting of inlet & outlet arrangements with base, riser of min. 0.42 m depth which includes earth work, fixing in CC-1:2:4 with appurtenances., complete. (c) civil works like Earthwork excavation for the pipeline trenches for laying of PVC-U pipes for the house connections in all types of soils , disintegrated rock,soft rock, hard rock, including cutting of any road using , crossing drains, compound, Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, c.c. wood work, steel work, including T & P and scaffolding wherever necessary sorting the dismantled material, disposal of unserviceable and stacking the serviceable material with all lifts and lead , restoring the damaged portions inside or outside the property premises, refilling the portions of trenches that are dug open including linking to existing sewer network with appurtenances. complete. 110 mm dia ---- Work Should be carried out in site as per Engineer incharge | Nos | 8134.0 | 8134.0 | 2.0 | False | None | None | False | None | False | 16268.0 | 0 | 2321490 | 68593 | None | Vol 1 P-5 1.4.1 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m ---- Work Should be carried out in site as per Engineer incharge | Cum | 242.0 | 242.0 | 9.0 | False | None | None | False | None | False | 2178.0 | 0 | 2321491 | 68593 | None | Vol 1 P-7 1.90 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m ---- Work Should be carried out in site as per Engineer incharge | Cum | 266.0 | 266.0 | 20.0 | False | None | None | False | None | False | 5320.0 | 0 | 2321492 | 68593 | None | Vol 5 P-191 16.9 | Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover ---- Work Should be carried out in site as per Engineer incharge | Nos | 5454.0 | 5454.0 | 4.0 | False | None | None | False | None | False | 21816.0 | 0 | 2321493 | 68593 | None | Vol 5 P-192 16.15.1 | Providing and constructing “WIRE CUT BRICK MACHINEHOLE CHAMBERS” using Portland / Pozzolana cement, conical in shape at top, with CC 1:3:6 foundation using 40 mm and down size graded metal of approved quality and with an offset of 0.15 M alround the chamber. Construct Brick masonry in CM 1:4, 340 mm thick, with wirecut bricks of approved quality, plaster inside and out side with CM 1:3, 12 mm thick, except for the conical surface outside where the plaster thickness shall be 20 mm. Slope inside to be 1:6 in the concrete towards central drain and finished smooth. Fixing of pipes in CC 1:2:4 with graded metal of 20 mm and down size. Supplying and fixing SFRC Machinehole frame and cover (Heavy Duty) conforming to IS:12592 with latest amendment, in CC 1:2:4. Supplying and fixing footsteps made of 12mm dia. steel bars (Fe-500) with 3 mm thick plastic encapsulation (IS-10910). The footsteps shall be fixed 30cms apart and on CC block embeded to masonry wall. The whole works include watering, curing, barricading, danger lighting, pouring tar over MH frame and cover, cost of tar, shoring, strutting, dewatering, engraving Machinehole number with flow direction on the inner conical surface etc. as per the drawing etc. as per technical specifications and for the following diameters and depth etc. for 1.2mm diaCirc. B M.HConstructing Brick Masonry Circular Machinehole 1.2 m internal dia. , 1.0 M depth & SFRC cover & frame ---- Work Should be carried out in site as per Engineer incharge | Nos | 29047.0 | 29047.0 | 2.0 | False | None | None | False | None | False | 58094.0 | 0 | 2321494 | 68593 | None | Vol 2 P-135 14.29 | Providing and fixing 100 mm sand cast Iron grating for gully trap. ---- Work Should be carried out in site as per Engineer incharge | Nos | 47.0 | 47.0 | 8.0 | False | None | None | False | None | False | 376.0 | 0 | 2321495 | 68593 | None | Vol 2 P-120 13.22.1.2 | Providing and fixing PTMT grating of approved quality and colour 125 mm nominal dia ---- Work Should be carried out in site as per Engineer incharge | Nos | 44.0 | 44.0 | 8.0 | False | None | None | False | None | False | 352.0 | 0 |
| 1706507527000 | 0 | None | None | Buildings | High School Electrical Work | 563904.6 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2321496 | 68594 | None | 1.2.1 (2 of 105) | Concealed Conduit System :Supplying heavy gauge PVC conduit pipe mm dia mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary19/20mm dia 2mm thick (PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Mtr | 66.0 | 66.0 | 525.0 | False | None | None | False | None | False | 34650.0 | 0 | 2321497 | 68594 | None | 1.2.2 (2 of 105) | Concealed Conduit System :Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary25mm dia 2mm thick.(PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Mtr | 78.0 | 78.0 | 175.0 | False | None | None | False | None | False | 13650.0 | 0 | 2321498 | 68594 | None | 1.3.1 (2 of 105) | Supplying heavy gauge PVC Conduit Pipe 25dia 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.19/20mm dia 2mm thick.(PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Mtr | 68.0 | 68.0 | 130.0 | False | None | None | False | None | False | 8840.0 | 0 | 2321499 | 68594 | None | 1.3.2 (2 of 105) | Supplying heavy gauge PVC Conduit Pipe 25dia 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.25mm dia 2mm thick.(PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Mtr | 79.0 | 79.0 | 100.0 | False | None | None | False | None | False | 7900.0 | 0 | 2321500 | 68594 | None | 1.9.2 (3 of 105) | Supplying PVC/GI flexible conduit pipe .... mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of the pipe terminated completely25mm.(PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Mtr | 22.0 | 22.0 | 30.0 | False | None | None | False | None | False | 660.0 | 0 | 2321501 | 68594 | None | 2.1.1 (5 of 105) | Point wiring using Copper wire with out switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm (Phase&Neutral) &1x1.0 Sqmm(earth Wire)Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto3mtr from tapping point to out let via Switch.(PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Point | 285.0 | 285.0 | 30.0 | False | None | None | False | None | False | 8550.0 | 0 | 2321502 | 68594 | None | 2.1.2 (5 of 105) | Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch.(PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Point | 394.0 | 394.0 | 62.0 | False | None | None | False | None | False | 24428.0 | 0 | 2321503 | 68594 | None | 2.1.3 (5 of 105) | Long point above 6Mtr upto 10Mtr from tapping point to out let via switch box.(PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Point | 570.0 | 570.0 | 8.0 | False | None | None | False | None | False | 4560.0 | 0 | 2321504 | 68594 | None | 2.3.2 (5 of 105) | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade,1.5 SQMM multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP.(PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Mtr | 26.0 | 26.0 | 300.0 | False | None | None | False | None | False | 7800.0 | 0 | 2321505 | 68594 | None | 2.3.3 (5 of 105) | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade,2.5 SQMM multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP.(PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Mtr | 42.0 | 42.0 | 600.0 | False | None | None | False | None | False | 25200.0 | 0 | 2321506 | 68594 | None | 2.3.4 (5 of 105) | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade,4 SQMM multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP.(PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Mtr | 63.0 | 63.0 | 200.0 | False | None | None | False | None | False | 12600.0 | 0 | 2321507 | 68594 | None | 2.3.5 (5 of 105) | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade,6 SQMM multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP.(PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Mtr | 92.0 | 92.0 | 100.0 | False | None | None | False | None | False | 9200.0 | 0 | 2321508 | 68594 | None | 3.4.2 (8 of 105) | Supplying and flush mounting powder coated / galvanized metal box size 1-3way suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall.(PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Each | 159.0 | 159.0 | 4.0 | False | None | None | False | None | False | 636.0 | 0 | 2321509 | 68594 | None | 3.4.3 (8 of 105) | Supplying and flush mounting powder coated / galvanized metal box size 4-5way suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall.(PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Each | 177.0 | 177.0 | 3.0 | False | None | None | False | None | False | 531.0 | 0 | 2321510 | 68594 | None | 3.4.5 (8 of 105) | Supplying and flush mounting powder coated / galvanized metal box size 8way suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall.(PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Each | 261.0 | 261.0 | 25.0 | False | None | None | False | None | False | 6525.0 | 0 | 2321511 | 68594 | None | 3.4.6 (8 of 105) | Supplying and flush mounting powder coated / galvanized metal box size 10-12way suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall.(PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Each | 319.0 | 319.0 | 30.0 | False | None | None | False | None | False | 9570.0 | 0 | 2321512 | 68594 | None | 3.5.2 (8 of 105) | Supplying and fixing superior quality 3Mudular modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal box.(PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Each | 161.0 | 161.0 | 4.0 | False | None | None | False | None | False | 644.0 | 0 | 2321513 | 68594 | None | 3.5.3 (8 of 105) | Supplying and fixing superior quality 4Mudular modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal box.(PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Each | 175.0 | 175.0 | 3.0 | False | None | None | False | None | False | 525.0 | 0 | 2321514 | 68594 | None | 3.5.5 (8 of 105) | Supplying and fixing superior quality 8 modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalbox.(PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Each | 284.0 | 284.0 | 25.0 | False | None | None | False | None | False | 7100.0 | 0 | 2321515 | 68594 | None | 3.5.6 (8 of 105) | Supplying and fixing superior quality 10-12Mudular modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalbox.(PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Each | 344.0 | 344.0 | 30.0 | False | None | None | False | None | False | 10320.0 | 0 | 2321516 | 68594 | None | 3.6.1 (9 of 105) | Supplying and fixing of 6Amps 0ne way modular switch on existing modular switch plate as per IS 3854 and IS 1293.(PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Each | 102.0 | 102.0 | 130.0 | False | None | None | False | None | False | 13260.0 | 0 | 2321517 | 68594 | None | 3.6.3 (9 of 105) | Supplying and fixing of 6Amps 3way modular Socketc on existing modular switch plate as per IS 3854 and IS 1293.(PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Each | 171.0 | 171.0 | 55.0 | False | None | None | False | None | False | 9405.0 | 0 | 2321518 | 68594 | None | 3.6.4 (9 of 105) | Supplying and fixing of modular stepped fan regulator Two Module on existing modular switch plate as per and IS 1293.(PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Each | 357.0 | 357.0 | 40.0 | False | None | None | False | None | False | 14280.0 | 0 | 2321519 | 68594 | None | 3.6.7 (9 of 105) | Supplying and fixing of 16Amps 0ne way modular switch on existing modular switch plate as per IS 3854 and IS 1293.(PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Each | 180.0 | 180.0 | 4.0 | False | None | None | False | None | False | 720.0 | 0 | 2321520 | 68594 | None | 3.6.9 (9 of 105) | Supplying and fixing of32Amps modular DP Switch on existing modular switch plate as per IS 3854 and IS 1293.(PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Each | 326.0 | 326.0 | 4.0 | False | None | None | False | None | False | 1304.0 | 0 | 2321521 | 68594 | None | 3.6.10 (9 of 105) | Supplying and fixing of 6/16amps modular Universal Socket on existing modular switch plate as per IS 3854 and IS 1293.(PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Each | 236.0 | 236.0 | 4.0 | False | None | None | False | None | False | 944.0 | 0 | 2321522 | 68594 | None | 3.14.6 (10 of 105) | Supplying and fixing of 6AmpsLamp holder on existing board.(PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Each | 71.0 | 71.0 | 100.0 | False | None | None | False | None | False | 7100.0 | 0 | 2321523 | 68594 | None | 5.7.3 (14 of 105) | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers.63amps.(PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Each | 401.0 | 401.0 | 3.0 | False | None | None | False | None | False | 1203.0 | 0 | 2321524 | 68594 | None | 5.18.1 (17 of 105) | Supplying and fixingof 6to32 Amps Single pole miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.(PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Each | 415.0 | 415.0 | 20.0 | False | None | None | False | None | False | 8300.0 | 0 | 2321525 | 68594 | None | 5.18.4 (17 of 105) | Supplying and fixingof 6to32 Amps Double pole miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.(PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Each | 739.0 | 739.0 | 6.0 | False | None | None | False | None | False | 4434.0 | 0 | 2321526 | 68594 | None | 5.19.9 (18 of 105) | Supplying and fixing 12way regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure.I - doble Door12way sp&n.(PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Each | 2329.0 | 2329.0 | 4.0 | False | None | None | False | None | False | 9316.0 | 0 | 2321527 | 68594 | None | 6.3.1 (30 of 105) | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm) Economy model.(PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Each | 2984.0 | 2984.0 | 30.0 | False | None | None | False | None | False | 89520.0 | 0 | 2321528 | 68594 | None | 11.3.2 (43 of 105) | LED Indood supplying of 1x4 feet LED PVC square batten 20/22 W with high quality diffuser with life of 25000 burning hours at 70% lumen maintenance with CRI 80 power input 220-240V@ 50Hz & Power Factor 0.9 along with CE approved drivers. 2 years Warrenty againest any manufacturing defect working under standard electrical condition (PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Each | 690.0 | 690.0 | 53.0 | False | None | None | False | None | False | 36570.0 | 0 | 2321529 | 68594 | None | 11..11.4 (47 of 105) | Supplying & fixing of retrofi ttype LED bulb...... Wwith OPALacry licdiffuser comprising of LED source with CCT 6500 degreeK, CRI70%. efficacy 80lumenper W, life25000 burning hoursand Compliance to IS10322/IEC60598, LM79&LM80. The LED are driven byHFelectronicdriverintegratedinthesystem,withPF0.95,powerlossshould 5 oflampWage.,shortcircuit&opencircuitprotectiontobeintegratedinthecircuit,THDlessthan20%,LifeasperLM79.Theoperatinginputvoltageshouldbebetween130to275V.BISApprovedandTestedbyNABL/CPRIaccreditedlaboratorywith2yearsWarrantyagains tany manufacturing defect working under standard electrical condition. (PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Each | 154.0 | 154.0 | 10.0 | False | None | None | False | None | False | 1540.0 | 0 | 2321530 | 68594 | None | 13.7.1 (56 of 105) | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps.(PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Each | 122.0 | 122.0 | 53.0 | False | None | None | False | None | False | 6466.0 | 0 | 2321531 | 68594 | None | 13.10 (57 of 105) | Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired.(PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Each | 171.0 | 171.0 | 30.0 | False | None | None | False | None | False | 5130.0 | 0 | 2321532 | 68594 | None | 12.56 (54 of 105) | Supplying,fixing,wiring,earthelectrodeforgroundingconduits,I.C.cutoutsandotherequipment'sonthemeterboardusing40mmdia2.90mmthickGIpipe2.5mlongburiedinapit.Thepitshouldbefilledwithequalproportionofsaltandcharcoal150mmall-roundthepipetocompletedepth.Theconnectionfromthepipetotheconduitetc.,istobeestablishedthroughGIwireofsizeasperlSIspecification7.3.3.ofIS732using12mmdiabolts,nuts,washersandchecknutsetc., the pipe shall have 16 through holes of 12 mm dia (PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | No | 3510.0 | 3510.0 | 3.0 | False | None | None | False | None | False | 10530.0 | 0 | 2321533 | 68594 | None | 32.07 (13 of 81) | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip25Sqmm, 3.5 Core, (12 GI Strips - 4 x 0.8 mm) (PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Km | 139549.0 | 139549.0 | 0.06 | False | None | None | False | None | False | 8372.94 | 0 | 2321534 | 68594 | None | 11.1.5 127 | Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990
with latest amendments complete with GI fittings (excluding the cost
of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For:Heavy Duty GI Pipe etc. complete Light Duty GI pipe of 40mm dia (Volume - 5 SR Water Supply and Sewerage Works) ---- Work Should be carried out in site as per Engineer incharge | Rmtr | 412.0 | 412.0 | 10.0 | False | None | None | False | None | False | 4120.0 | 0 | 2321535 | 68594 | None | 1.4.1 5 | Earth work excavation by manual means for drains, canals, waste weir, draft,approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the
selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.( PWD common SR Vol-I 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Cum | 242.0 | 242.0 | 22.0 | False | None | None | False | None | False | 5324.0 | 0 | 2321536 | 68594 | None | 1.10 7 | Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour complete as per specifications ( PWD common SR Vol-I 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Cum | 160.0 | 160.0 | 22.0 | False | None | None | False | None | False | 3520.0 | 0 | 2321537 | 68594 | None | 21.05 (52 of 81) | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 to 25 Sqmm (PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Km | 20886.0 | 20886.0 | 0.06 | False | None | None | False | None | False | 1253.16 | 0 | 2321538 | 68594 | None | 5.37 (19 of 105) | Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 V grade, for power factor improvement of rotating machineries like induction motor.(PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Kvar | 480.0 | 480.0 | 50.0 | False | None | None | False | None | False | 24000.0 | 0 | 2321539 | 68594 | None | 5.38 (19 of 105) | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz12/24V D.C (PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Each | 515.0 | 515.0 | 3.0 | False | None | None | False | None | False | 1545.0 | 0 | 2321540 | 68594 | None | 5.40.1 (20 of 105) | Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete.100 A 4 x 30 x 10 mm Aluminium Strips (PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Mtr | 2465.0 | 2465.0 | 1.5 | False | None | None | False | None | False | 3697.5 | 0 | 2321541 | 68594 | None | 5.41.2 (20 of 105) | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.50 x 50 x 6 mm (PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Mtr | 395.0 | 395.0 | 10.0 | False | None | None | False | None | False | 3950.0 | 0 | 2321542 | 68594 | None | 5.42.2 (21 of 105) | Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.16 SWG ((PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Sq CM | 0.43 | 0.43 | 75000.0 | False | None | None | False | None | False | 32250.0 | 0 | 2321543 | 68594 | None | 6.1 (30 of 105) | Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.(PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Nos | 1492.0 | 1492.0 | 1.0 | False | None | None | False | None | False | 1492.0 | 0 | 2321544 | 68594 | None | 11.8.2 (46 of 105) | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 &LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part.Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source..LED Streetlight 40 W (PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Nos | 4024.0 | 4024.0 | 3.0 | False | None | None | False | None | False | 12072.0 | 0 | 2321545 | 68594 | None | 13.1.1 (56 of 105) | Supplying and Fixing of........mm dia class A GI pipe bracket upto 2 ms long bent at suitable angle and fixing to this bracket 1x40/2x40 W fluorescent tube street light fitting of all capacities to GI or GI or rail or RCC pole / wall using suitable clA, bolts, and nuts and wiring using suitable capacity wires.Using 25mm dia G.I.Pipe(PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Each | 978.0 | 978.0 | 3.0 | False | None | None | False | None | False | 2934.0 | 0 | 2321546 | 68594 | None | 13.14 (57 of 105) | Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire..(PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Each | 492.0 | 492.0 | 1.0 | False | None | None | False | None | False | 492.0 | 0 | 2321547 | 68594 | None | 5.15.9 (17 of 105) | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws,
bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal
Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles
should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and
Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front
cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover
open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.FOUR Pole.100A 25 kA (PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Each | 8487.0 | 8487.0 | 1.0 | False | None | None | False | None | False | 8487.0 | 0 | 2321548 | 68594 | None | 5.20.1 (18 of 105) | Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board.16A-25A 2 pole (PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Each | 4277.0 | 4277.0 | 1.0 | False | None | None | False | None | False | 4277.0 | 0 | 2321549 | 68594 | None | 5.21 (18 of 105) | Supplying,fixingandwiringearthleakagerelaywithcorebalancedcurrenttransformersuitableforsinglephase50HzACwithlatestmicrocontrollerbased,digitalreadoutofpercentageleakagecurrent,programmabledelay/auto/manualresetfacilitysuitabletomountonDIN rail/ flush mounting on panel board.(PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Nos | 9255.0 | 9255.0 | 1.0 | False | None | None | False | None | False | 9255.0 | 0 | 2321550 | 68594 | None | 5.22 (18 of 105) | Supplying, fixing and wiring 0 to 600V 96x96mm AC Voltmeter on existing panel/wood board. pole (PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Each | 452.0 | 452.0 | 1.0 | False | None | None | False | None | False | 452.0 | 0 | 2321551 | 68594 | None | 5.24 (18 of 105) | Supplying, fixing and wiring 0 to 30A Direct Reading AC analog type Ammeter (PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Each | 465.0 | 465.0 | 1.0 | False | None | None | False | None | False | 465.0 | 0 | 2321552 | 68594 | None | 5.26 (18 of 105) | Supplying, fixing and wiring 0 to 1500A CT operated AC analog type Ammeter without CT (PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Each | 480.0 | 480.0 | 1.0 | False | None | None | False | None | False | 480.0 | 0 | 2321553 | 68594 | None | 5.29 (19 of 105) | Supplying, fixing and wiring 3 Phase Digital Ammeter / Voltmeter (PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Each | 1425.0 | 1425.0 | 2.0 | False | None | None | False | None | False | 2850.0 | 0 | 2321554 | 68594 | None | 5.31 (19 of 105) | Supplying and fixing Electronic Trivector Meter (ETV) suitable for operation LT operation and -CT operated meter in
polycarbonate body in class 0.5 accuracy as per IS 14697 and completely wired.(PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Nos | 4390.0 | 4390.0 | 1.0 | False | None | None | False | None | False | 4390.0 | 0 | 2321555 | 68594 | None | 5.33 (19 of 105) | Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power,
power factor, kVA, kWH, kVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired
as required with communication Port and Class 0.5s accuracy (PWD Electrical SR-II 2023-24) ---- Work Should be carried out in site as per Engineer incharge | Each | 9315.0 | 9315.0 | 1.0 | False | None | None | False | None | False | 9315.0 | 0 | 2321556 | 68594 | None | HESCOM approval | Providing TC for power supply arrangement as per HESCOM approval ---- Work Should be carried out in site as per Engineer incharge | Each | 5000.0 | 5000.0 | 1.0 | False | None | None | False | None | False | 5000.0 | 0 |
| 1706507527000 | 0 | None | None | Buildings | High School SEPTIC TANK | 186307.86 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2321557 | 68595 | None | Vol 1 P-8 1.12 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth ---- Work Should be carried out in site as per Engineer incharge | Cum | 95.0 | 95.0 | 3.29 | False | None | None | False | None | False | 312.55 | 0 | 2321558 | 68595 | None | Vol 1 P-8 1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m ---- Work Should be carried out in site as per Engineer incharge | Cum | 102.0 | 102.0 | 32.92 | False | None | None | False | None | False | 3357.84 | 0 | 2321559 | 68595 | None | Vol 2 P-13 6.1 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding
and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. ---- Work Should be carried out in site as per Engineer incharge | Cum | 8220.0 | 8220.0 | 9.09 | False | None | None | False | None | False | 74719.8 | 0 | 2321560 | 68595 | None | Vol 1 P-18 2.10.c | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade. Plinth Beam ---- Work Should be carried out in site as per Engineer incharge | Cum | 6219.0 | 6219.0 | 1.92 | False | None | None | False | None | False | 11940.48 | 0 | 2321561 | 68595 | None | Vol 1 P-111 1.a | Formwork, Centering & Scaffloding 50% For Plinth Beams ---- Work Should be carried out in site as per Engineer incharge | Cum | 3109.5 | 3109.5 | 1.92 | False | None | None | False | None | False | 5970.24 | 0 | 2321562 | 68595 | None | Vol 1 18 2.10.c | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade. For Slab ---- Work Should be carried out in site as per Engineer incharge | Cum | 6219.0 | 6219.0 | 3.01 | False | None | None | False | None | False | 18719.19 | 0 | 2321563 | 68595 | None | Vol 1 111 9 | Formwork, Centering & Scaffloding 50% For Slab ---- Work Should be carried out in site as per Engineer incharge | Cum | 3109.5 | 3109.5 | 3.01 | False | None | None | False | None | False | 9359.595 | 0 | 2321564 | 68595 | None | Vol 2 18 2.11.a | Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings ---- Work Should be carried out in site as per Engineer incharge | Tonne | 89457.0 | 89457.0 | 0.53 | False | None | None | False | None | False | 47412.21 | 0 | 2321565 | 68595 | None | Vol 2 41 8.1.2 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- Work Should be carried out in site as per Engineer incharge | Sqm | 241.0 | 241.0 | 43.95 | False | None | None | False | None | False | 10591.95 | 0 | 2321566 | 68595 | None | Vol 5 221 18.3 | Providing & fixing 455x610 mm cast iron cover with frame weight to be not less 38kgs (weight of cover 23 kgs and weight of frame 15 kgs)and necessary locking arrangements with M.S flats 32x6 mm etc & painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge. ---- Work Should be carried out in site as per Engineer incharge | Each | 1962.0 | 1962.0 | 2.0 | False | None | None | False | None | False | 3924.0 | 0 |
|
|
---|