2400366 | 71569 | None | code01 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) (UNI SR Volume-1) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - PAGE - 17 - 2.5.2 | Cum | 10940.0 | 10940.0 | 6.805 | False | None | None | False | None | False | 74446.7 | 0 |
2400367 | 71569 | None | code02 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) (UNI SR Volume-1) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - PAGE - 17 - 2.5.2 | Cum | 11048.32 | 11048.32 | 1.22 | False | None | None | False | None | False | 13478.9504 | 0 |
2400368 | 71569 | None | code03 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirments of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Sill - PAGE - 17 - 2.5.1 | Cum | 10289.82 | 10289.82 | 1.79 | False | None | None | False | None | False | 18418.7778 | 0 |
2400369 | 71569 | None | code04 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Plinth beams,Curtain wall, Beams,Lintel,Slab - PAGE - 17 - 2.5.2 | Cum | 10296.47 | 10296.47 | 3.58 | False | None | None | False | None | False | 36861.3626 | 0 |
2400370 | 71569 | None | code05 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Plinth beams,Curtain wall, Beams,Lintel,Slab - PAGE - 17 - 2.5.2 | Cum | 10296.47 | 10296.47 | 10.61 | False | None | None | False | None | False | 109245.5467 | 0 |
2400371 | 71569 | None | code06 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Plinth beams,Curtain wall, Beams,Lintel,Slab - PAGE - 17 - 2.5.2 | Cum | 9652.94 | 9652.94 | 20.63 | False | None | None | False | None | False | 199140.1522 | 0 |
2400372 | 71569 | None | code07 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirments of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) )M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Chejja - PAGE - 17 - 2.5.2 | Cum | 9325.15 | 9325.15 | 1.12 | False | None | None | False | None | False | 10444.168 | 0 |
2400373 | 71569 | None | code08 | Providing Thermo-Mechanically Treated bars of grade Fe-550 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately - PAGE - 84 - 11.23 | Kg | 95.71 | 95.71 | 5467.7 | False | None | None | False | None | False | 523313.567 | 0 |
2400374 | 71569 | None | code09 | Providing Brick work with common burnt clay machine moulded perforated bricks of class designation 5.0 conforming to IS: 2222 in superstructure above plinth level in cement mortar 1:6 (1 cement : 6 coarse sand) With Modular bricks including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. VOL-2 - PAGE - 17 - 2.5.2 | Cum | 9942.15 | 9942.15 | 59.1 | False | None | None | False | None | False | 587581.065 | 0 |
2400375 | 71569 | None | code10 | Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. - PAGE - 98 - 12.13.2 | Cum | 64085.6 | 64085.6 | 0.03 | False | None | None | False | None | False | 1922.568 | 0 |
2400376 | 71569 | None | code11 | Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. - PAGE - 98 - 12.13.2 | Cum | 64085.6 | 64085.6 | 0.02 | False | None | None | False | None | False | 1281.712 | 0 |
2400377 | 71569 | None | code12 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. 35 mm thick both side commercial - PAGE - 106 - 12.57.6 | Sqm | 3062.64 | 3062.64 | 6.0 | False | None | None | False | None | False | 18375.84 | 0 |
2400378 | 71569 | None | code13 | Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Vol-2 12.89 | Sqm | 6992.9 | 6992.9 | 32.4 | False | None | None | False | None | False | 226569.96 | 0 |
2400379 | 71569 | None | code14 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. - PAGE - 85 - 11.34B | Kg | 163.33 | 163.33 | 777.6 | False | None | None | False | None | False | 127005.408 | 0 |
2400380 | 71569 | None | code15 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with whitecement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, Lakared, River Pink, Orissa Blue or equivalent. - PAGE - 63 - 9.24 | Sqm | 2985.66 | 2985.66 | 118.48 | False | None | None | False | None | False | 353740.9968 | 0 |
2400381 | 71569 | None | code16 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with whitecement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, Lakared, River Pink, Orissa Blue or equivalent. - PAGE - 63 - 9.24 | Sqm | 2985.66 | 2985.66 | 172.72 | False | None | None | False | None | False | 515683.1952 | 0 |
2400382 | 71569 | None | code17 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. VOL-2 - - PAGE - 41 - 8.2.1 | Sqm | 257.99 | 257.99 | 268.37 | False | None | None | False | None | False | 69236.7763 | 0 |
2400383 | 71569 | None | code18 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. - PAGE - 50 - 8.51 | Sqm | 86.34 | 86.34 | 268.37 | False | None | None | False | None | False | 23171.0658 | 0 |
2400384 | 71569 | None | code19 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. - PAGE - 50 - 8.51 | Sqm | 86.34 | 86.34 | 180.96 | False | None | None | False | None | False | 15624.0864 | 0 |
2400385 | 71569 | None | code20 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Out side) - PAGE - 42 - 8.8 | Sqm | 319.37 | 319.37 | 350.1 | False | None | None | False | None | False | 111811.437 | 0 |
2400386 | 71569 | None | code21 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. - PAGE - 41 - 8.1.2 | Sqm | 205.98 | 205.98 | 180.96 | False | None | None | False | None | False | 37274.1408 | 0 |
2400387 | 71569 | None | code22 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. - PAGE - 46 - 8.33.1 | Sqm | 122.76 | 122.76 | 180.96 | False | None | None | False | None | False | 22214.6496 | 0 |
2400388 | 71569 | None | code23 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paer smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge - PAGE - 46 - 8.300 | Sqm | 141.48 | 141.48 | 180.96 | False | None | None | False | None | False | 25602.2208 | 0 |
2400389 | 71569 | None | code24 | Finishing with Epoxy paint (two coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Enginer-in-charge. VOL-2 - - PAGE - 47 - 8.36.1 | Sqm | 143.56 | 143.56 | 32.4 | False | None | None | False | None | False | 4651.344 | 0 |
2400390 | 71569 | None | code25 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. VOL-2- - PAGE - 46 - 8.33.2 | Sqm | 109.23 | 109.23 | 14.4 | False | None | None | False | None | False | 1572.912 | 0 |
2400391 | 71569 | None | code26 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with whitecement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, Lakared, River Pink, Orissa Blue or equivalent. - PAGE - 46 - 9.24 | Sqm | 2985.66 | 2985.66 | 31.02 | False | None | None | False | None | False | 92615.1732 | 0 |
2400392 | 71569 | None | code27 | Providing Brick work with common burnt clay machine moulded perforated bricks of class designation 5.0 conforming to IS: 2222 in superstructure above plinth level in cement mortar 1:6 (1 cement : 6 coarse sand) With Modular bricks including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. VOL-2- - PAGE - 63 - 6.6 | Cum | 9942.15 | 9942.15 | 0.87 | False | None | None | False | None | False | 8649.6705 | 0 |
2400393 | 71569 | None | code28 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. - VOL-2 - 15.1 | Sqm | 775.02 | 775.02 | 160.0 | False | None | None | False | None | False | 124003.2 | 0 |
2400394 | 71569 | None | code29 | Providing Brick work with common burnt clay machine moulded perforated bricks of class designation 5.0 conforming to IS: 2222 in superstructure above plinth level in cement mortar 1:6 (1 cement : 6 coarse sand) With Modular bricks including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. VOL-2- 6.6 | Cum | 9942.15 | 9942.15 | 1.42 | False | None | None | False | None | False | 14117.853 | 0 |
2400395 | 71569 | None | code30 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. - PAGE - 103 - 12.51 | No | 1540.68 | 1540.68 | 2.0 | False | None | None | False | None | False | 3081.36 | 0 |
2400396 | 71569 | None | code31 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessoris such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. - PAGE - 83 - 11.28 | Sqm | 520.15 | 520.15 | 8.9 | False | None | None | False | None | False | 4629.335 | 0 |
2400397 | 71569 | None | code32 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. VOL-2- - PAGE - 107 - 12.51 | No | 113.39 | 113.39 | 4.0 | False | None | None | False | None | False | 453.56 | 0 |
2400398 | 71569 | None | code33 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. VOL-2- - PAGE - 107 - 12.59 | No | 915.46 | 915.46 | 2.0 | False | None | None | False | None | False | 1830.92 | 0 |
2400399 | 71569 | None | code34 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. VOL-2- - PAGE - 107 - 12.60 | No | 865.53 | 865.53 | 2.0 | False | None | None | False | None | False | 1731.06 | 0 |
2400400 | 71569 | None | code35 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete - VOL-2- - PAGE - 107 - 12.62 | No | 182.05 | 182.05 | 2.0 | False | None | None | False | None | False | 364.1 | 0 |
2400401 | 71569 | None | code36 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete - VOL -2- - PAGE - 107 - 12.63 | No | 115.47 | 115.47 | 2.0 | False | None | None | False | None | False | 230.94 | 0 |
2400402 | 71569 | None | code37 | KSRB 15.8.1 : Providing and fixing plaster mesh (GI expanded metal mesh) 100 mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35 mm with a zinc coating of 120 gms per sqm width, along route of walls clipped for services, junction between RCC and brick walls including cost of materials,labour for fixing complete as per specifications. (length of the mesh only be measured for payment) (Page no :111 item no:15.34 S.R. of PWD,) | m | 27.05 | 27.05 | 38.2 | False | None | None | False | None | False | 1033.31 | 0 |
2400403 | 71569 | None | code38 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: Vol 5 Page 134 - M010--PVC pipes 32mm dia., 10 kg/sqcm & class 5 | m | 61.31 | 61.31 | 12.0 | False | None | None | False | None | False | 735.72 | 0 |
2400404 | 71569 | None | code39 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: Vol 5 Page 134 - M010--PVC pipes 75mm dia., 6 kg/sqcm & class 3 | m | 201.16 | 201.16 | 54.0 | False | None | None | False | None | False | 10862.64 | 0 |
2400405 | 71569 | None | code40 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: Vol 5 Page 134 - M010--PVC pipes 110mm dia., 6 kg/sqcm & class 3 | m | 377.41 | 377.41 | 80.0 | False | None | None | False | None | False | 30192.8 | 0 |
2400406 | 71569 | None | code41 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25mm dia VOIL - 2- PAGE-115 - 13.4.1 | No | 543.84 | 543.84 | 2.0 | False | None | None | False | None | False | 1087.68 | 0 |
2400407 | 71569 | None | code42 | Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Vol 2
Page 191 - 14.11.2 | No | 4783.32 | 4783.32 | 4.0 | False | None | None | False | None | False | 19133.28 | 0 |
2400408 | 71569 | None | code43 | Providing and fixing 3 layer PP-R (Poly Propylene Random Copolymer) pipes confirming to IS.15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply, including all PP-R plain and brass threaded polypropylene random fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineer-In- Charge. Vol 5 Page 34- 5895- 20 mm Outer dia | m | 63.86 | 63.86 | 30.0 | False | None | None | False | None | False | 1915.8 | 0 |
2400409 | 71569 | None | code44 | Providing and fixing PTMT pillar cock of approved quality and colour. 15 mm nominal bore, 125 mm long foam flow, weighing not less than 120 gms : Vol 2 Page 118 - 13.20.2 | No | 226.6 | 226.6 | 4.0 | False | None | None | False | None | False | 906.4 | 0 |
2400410 | 71569 | None | code45 | Constructing brick masonry chamber of internal dimension 450x300mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.. (Gully trap) Vol 5 Page 188 - T130D | No | 3337.2 | 3337.2 | 2.0 | False | None | None | False | None | False | 6674.4 | 0 |
2400411 | 71569 | None | code46 | Earth work excavation for pipeline trenches in all kinds of soils bymechanical means above 600 mm trench width as per drawing andtechnical specifications, including setting out, construction of shoring,strutting, barricading, caution lights, bracing, using sight rails & boningrods at every 100 mm whevere necessary as directed, removal ofstumps and other deleterious matter, dressing of sides and levellingthe bottom of trench to the extent required , utilising the availableexcavated earth locally for the work etc., and all other appurtenancescomplete in the following strata. Depth upto 1.2 M. 1.17.1 | Cum | 199.82 | 199.82 | 10.0 | False | None | None | False | None | False | 1998.2 | 0 |
2400412 | 71569 | None | code47 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. Vol 5 Page 216 - 17.1 | Cum | 988.8 | 988.8 | 3.0 | False | None | None | False | None | False | 2966.4 | 0 |
2400413 | 71569 | None | code48 | Supplying, filling, spreading &leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. Vol 5 Page 216 - 17.2 | Cum | 383.16 | 383.16 | 3.0 | False | None | None | False | None | False | 1149.48 | 0 |
2400414 | 71569 | None | code49 | Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. Vol 5 Page 216 - 17.3 | Cum | 408.91 | 408.91 | 3.0 | False | None | None | False | None | False | 1226.73 | 0 |
2400415 | 71569 | None | code50 | Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. Vol 5 Page 216 - 17.4 | Cum | 412.0 | 412.0 | 3.0 | False | None | None | False | None | False | 1236.0 | 0 |
2400416 | 71569 | None | code51 | Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge. Vol 5 Page 216 - 17.5 | Each | 1224.67 | 1224.67 | 30.0 | False | None | None | False | None | False | 36740.1 | 0 |
2400417 | 71569 | None | code52 | Providing and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete Vol 5 Page 216 - 17.14 | Sqm | 1147.42 | 1147.42 | 3.0 | False | None | None | False | None | False | 3442.26 | 0 |
2400418 | 71569 | None | code53 | Internal Wiring - Point wiring using Copper wire with switch Supplying & wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5sqmm (Phase & Neutral) & 1x1.0sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. PAGE-3-2.2.1---Short point upto 3Mtr from tapping point to outlet via switch. | Point | 251.0 | 251.0 | 10.0 | False | None | None | False | None | False | 2510.0 | 0 |
2400419 | 71569 | None | code54 | Internal Wiring - Point wiring using Copper wire with switch Supplying & wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5sqmm (Phase & Neutral) & 1x1.0sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. PAGE-3-2.2.2 -- Medium point above 3Mtr upto 6Mtr from tapping point to outlet via switch. | Point | 361.0 | 361.0 | 8.0 | False | None | None | False | None | False | 2888.0 | 0 |
2400420 | 71569 | None | code55 | Internal Wiring - Point wiring using Copper wire with switch Supplying & wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5sqmm (Phase & Neutral) & 1x1.0sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. PAGE-3-2.2.3 -- Long point above 6Mtr upto 10Mtr from tapping point to outlet via switch. | Point | 542.0 | 542.0 | 5.0 | False | None | None | False | None | False | 2710.0 | 0 |
2400421 | 71569 | None | code56 | Internal Wiring - Point wiring using Copper wire with switch Supplying & wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5sqmm (Phase & Neutral) & 1x1.0sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. PAGE-3-2.2.4--Two outlet in a row, above 3 Mtr upto 6 Mtr from tapping point to out let via switches. | Point | 671.0 | 671.0 | 5.0 | False | None | None | False | None | False | 3355.0 | 0 |
2400422 | 71569 | None | code57 | Internal Wiring - Point wiring using Copper wire with switch Supplying & wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5sqmm (Phase & Neutral) & 1x1.0sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. PAGE-3-2.2.5 -- Three outlet in a row, above 6 Mts upto 10 Mtr from tapping point to out let via switches. | Point | 979.0 | 979.0 | 10.0 | False | None | None | False | None | False | 9790.0 | 0 |
2400423 | 71569 | None | code58 | Supplying heavy gauge PVC conduit pipe 2mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. PAGE-1 - 1.2.1--19/20mm dia 2mm thick | m | 61.0 | 61.0 | 115.0 | False | None | None | False | None | False | 7015.0 | 0 |
2400424 | 71569 | None | code59 | Supplying heavy gauge PVC conduit pipe 2mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. PAGE-1 - 1.2.2 --- 25mm dia 2mm thick | m | 70.0 | 70.0 | 85.0 | False | None | None | False | None | False | 5950.0 | 0 |
2400425 | 71569 | None | code60 | Supplying heavy gauge PVC conduit pipe 2mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. PAGE-1 - 1.2.3 -- 32mm dia 2.5mm thick | m | 93.0 | 93.0 | 30.0 | False | None | None | False | None | False | 2790.0 | 0 |
2400426 | 71569 | None | code61 | Supplying heavy gauge PVC Conduit Pipe 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit
wherever necessary. PAGE-1-1.3.1 -- 19/20mm dia 2mm thick | m | 75.0 | 75.0 | 55.0 | False | None | None | False | None | False | 4125.0 | 0 |
2400427 | 71569 | None | code62 | Supplying heavy gauge PVC Conduit Pipe 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit
wherever necessary. PAGE-1-1.3.2 --- 25mm dia 2mm thick | m | 80.0 | 80.0 | 35.0 | False | None | None | False | None | False | 2800.0 | 0 |
2400428 | 71569 | None | code63 | Supplying heavy gauge PVC Conduit Pipe 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit
wherever necessary. PAGE-1-1.3.3 --- 32mm dia 2.5mm thick | m | 105.0 | 105.0 | 10.0 | False | None | None | False | None | False | 1050.0 | 0 |
2400429 | 71569 | None | code64 | Supplying and fixing PVC/metal conduit Deep junction box -- PAGE-1 - 1.5.1 --- 19/20mm deep junction box | Each | 49.0 | 49.0 | 25.0 | False | None | None | False | None | False | 1225.0 | 0 |
2400430 | 71569 | None | code65 | Supplying and fixing PVC/metal conduit Deep junction box -- PAGE-1 - 1.5.2 --- 25mm deep junction box | Each | 51.0 | 51.0 | 25.0 | False | None | None | False | None | False | 1275.0 | 0 |
2400431 | 71569 | None | code66 | Supplying and fixing PVC/metal conduit Deep junction box -- PAGE-1 - 1.5.3 --- 32mm deep junction box | Each | 69.0 | 69.0 | 10.0 | False | None | None | False | None | False | 690.0 | 0 |
2400432 | 71569 | None | code67 | Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300mm …. etc. as required. PAGE-2 - 1.8.1 --- 20mm | m | 27.0 | 27.0 | 25.0 | False | None | None | False | None | False | 675.0 | 0 |
2400433 | 71569 | None | code68 | Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300mm …. etc. as required. PAGE-2 - 1.8.2 --- 25mm | m | 28.0 | 28.0 | 45.0 | False | None | None | False | None | False | 1260.0 | 0 |
2400434 | 71569 | None | code69 | Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300mm …. etc. as required. PAGE-2 - 1.8.3 --- 32mm | m | 41.0 | 41.0 | 10.0 | False | None | None | False | None | False | 410.0 | 0 |
2400435 | 71569 | None | code70 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cuttingin Brick/Stone/C.C wall. PAGE-5 - 3.4.1 -- 1-3Way | Each | 123.0 | 123.0 | 3.0 | False | None | None | False | None | False | 369.0 | 0 |
2400436 | 71569 | None | code71 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cuttingin Brick/Stone/C.C wall. PAGE-5 - 3.4.2 -- 4-5Way | Each | 138.0 | 138.0 | 5.0 | False | None | None | False | None | False | 690.0 | 0 |
2400437 | 71569 | None | code72 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cuttingin Brick/Stone/C.C wall. PAGE-5 - 3.4.3 --- 6Way | Each | 212.0 | 212.0 | 3.0 | False | None | None | False | None | False | 636.0 | 0 |
2400438 | 71569 | None | code73 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cuttingin Brick/Stone/C.C wall. PAGE-5 - 3.4.4 --- 8Way | Each | 250.0 | 250.0 | 24.0 | False | None | None | False | None | False | 6000.0 | 0 |
2400439 | 71569 | None | code74 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cuttingin Brick/Stone/C.C wall. PAGE-5 - 3.4.5 --- 10-12Way | Each | 325.0 | 325.0 | 4.0 | False | None | None | False | None | False | 1300.0 | 0 |
2400440 | 71569 | None | code75 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. PAGE -5 - 3.5.1 --- 1 to 3 Module | Each | 152.0 | 152.0 | 3.0 | False | None | None | False | None | False | 456.0 | 0 |
2400441 | 71569 | None | code76 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. PAGE -5 - 3.5.2 -- 4 Module | Each | 175.0 | 175.0 | 5.0 | False | None | None | False | None | False | 875.0 | 0 |
2400442 | 71569 | None | code77 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. PAGE -5 - 3.5.3 --- 6 Module | Each | 244.0 | 244.0 | 3.0 | False | None | None | False | None | False | 732.0 | 0 |
2400443 | 71569 | None | code78 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. PAGE -5 - 3.5.4 --- 8 Module | Each | 302.0 | 302.0 | 24.0 | False | None | None | False | None | False | 7248.0 | 0 |
2400444 | 71569 | None | code79 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. PAGE -5 - 3.5.5 --- 10 -12 Module | Each | 363.0 | 363.0 | 4.0 | False | None | None | False | None | False | 1452.0 | 0 |
2400445 | 71569 | None | code80 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. PAGE-5 - 3.6.1 -- 6Amps one way Switch | Each | 88.0 | 88.0 | 65.0 | False | None | None | False | None | False | 5720.0 | 0 |
2400446 | 71569 | None | code81 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. PAGE-5 - 3.6.2 -- 6Amps Two way Switch | Each | 152.0 | 152.0 | 2.0 | False | None | None | False | None | False | 304.0 | 0 |
2400447 | 71569 | None | code82 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. PAGE-5 - 3.6.3 --- 6Amps 3way socket | Each | 162.0 | 162.0 | 28.0 | False | None | None | False | None | False | 4536.0 | 0 |
2400448 | 71569 | None | code83 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. PAGE-5 - 3.6.4 --- Stepped Fan Regulator | Each | 313.0 | 313.0 | 12.0 | False | None | None | False | None | False | 3756.0 | 0 |
2400449 | 71569 | None | code84 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. PAGE-5 - 3.6.8 --- 16Amps one way switch | Each | 249.0 | 249.0 | 24.0 | False | None | None | False | None | False | 5976.0 | 0 |
2400450 | 71569 | None | code85 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. PAGE-5 - 3.6.11 --- 6/16Amps universal socket | Each | 249.0 | 249.0 | 24.0 | False | None | None | False | None | False | 5976.0 | 0 |
2400451 | 71569 | None | code86 | Supplying And Fixing M.S Rafter Clamp Set made out of M.S Flat & 14mm M.S rod. PAGE-2 - 1.11 | No | 159.0 | 159.0 | 12.0 | False | None | None | False | None | False | 1908.0 | 0 |
2400452 | 71569 | None | code87 | Supplying And Fixing Metal Fan Box with Round Hook. PAGE-2 - 1.12 | No | 163.0 | 163.0 | 12.0 | False | None | None | False | None | False | 1956.0 | 0 |
2400453 | 71569 | None | code88 | Extra length of GI pipe of class B 19mm dia for down rod. PAGE-46 - 1.13 | No | 173.0 | 173.0 | 12.0 | False | None | None | False | None | False | 2076.0 | 0 |
2400454 | 71569 | None | code89 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. PAGE-3-2.3.2 -- 1.5 sqmm | m | 26.0 | 26.0 | 100.0 | False | None | None | False | None | False | 2600.0 | 0 |
2400455 | 71569 | None | code90 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. PAGE-3-2.3.3 -- 2.5 sqmm | m | 40.0 | 40.0 | 225.0 | False | None | None | False | None | False | 9000.0 | 0 |
2400456 | 71569 | None | code91 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. PAGE-3-2.3.4 --- 4.0 sqmm | m | 59.0 | 59.0 | 400.0 | False | None | None | False | None | False | 23600.0 | 0 |
2400457 | 71569 | None | code92 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. PAGE-3-2.3.5 -- 6.0 sqmm | m | 87.0 | 87.0 | 50.0 | False | None | None | False | None | False | 4350.0 | 0 |
2400458 | 71569 | None | code93 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. PAGE-3-2.3.6 --- 10.0 sqmm | m | 157.0 | 157.0 | 200.0 | False | None | None | False | None | False | 31400.0 | 0 |
2400459 | 71569 | None | code94 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure. PAGE-13 - 5.18.12 6WAY TP & N | Each | 3735.0 | 3735.0 | 1.0 | False | None | None | False | None | False | 3735.0 | 0 |
2400460 | 71569 | None | code95 | Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker (ELMCB) 240/450V up to 300mA sensitivity on existing wood/panel board. PAGE-13 - 5.20 - 5.20.3 -- 32-40 Amps 4 pole | Each | 2826.0 | 2826.0 | 1.0 | False | None | None | False | None | False | 2826.0 | 0 |
2400461 | 71569 | None | code96 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. PAGE - 13 - 5.17.1 -- 6-32Amps SP | Each | 523.0 | 523.0 | 18.0 | False | None | None | False | None | False | 9414.0 | 0 |
2400462 | 71569 | None | code97 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. PAGE - 13 - 5.17.9 -- 50-63Amps TPN | Each | 2399.0 | 2399.0 | 1.0 | False | None | None | False | None | False | 2399.0 | 0 |
2400463 | 71569 | None | code98 | Supplying of 4feet - PVC Batten with integrated LED tube with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. PAGE - 34- 11.3.1 ---LED light fighting 2'-14watts | Each | 496.0 | 496.0 | 5.0 | False | None | None | False | None | False | 2480.0 | 0 |
2400464 | 71569 | None | code99 | Supplying of 4feet - PVC Batten with integrated LED tube with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. PAGE - 34- 11.3.3 --- LED light fighting 4'-36watts | Each | 1197.0 | 1197.0 | 20.0 | False | None | None | False | None | False | 23940.0 | 0 |
2400465 | 71569 | None | code100 | Supply of round/square recess/surface mounted rolling type LED Down light with GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition -- LED square or round down light 15-18W -- PAGE - 34- 11.5.1 | Each | 1249.0 | 1249.0 | 10.0 | False | None | None | False | None | False | 12490.0 | 0 |
2400466 | 71569 | None | code101 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. --- 48" Sweep (1200mm) Regular model -- PAGE - 22- 6.3.1 | Each | 2085.0 | 2085.0 | 12.0 | False | None | None | False | None | False | 25020.0 | 0 |
2400467 | 71569 | None | code102 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. PAGE-13.7.1 | Each | 119.0 | 119.0 | 35.0 | False | None | None | False | None | False | 4165.0 | 0 |
2400468 | 71569 | None | code103 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. PAGE - 46- 13.10 | Each | 162.0 | 162.0 | 12.0 | False | None | None | False | None | False | 1944.0 | 0 |
2400469 | 71569 | None | code104 | Supplying and fixing of Leaf trap with kurra made out of UPVC with flange and grating for rain water outlets on terrace etc., complete. | No | 1350.0 | 1350.0 | 6.0 | False | None | None | False | None | False | 8100.0 | 0 |
2400470 | 71569 | None | code105 | Green BOARD | No | 8099.15 | 8099.15 | 2.0 | False | None | None | False | None | False | 16198.3 | 0 |