1706860345000 | 0 | None | None | Buildings | Construction of Laboratory and other works for Government Polytechnic college at Belur in Hassan district under SCP/TSP 2022-23 Scheme | 3724112.13 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2400472 | 71571 | None | code01 | Clearing and grubbing road land including uprooting rank
vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.-By Mechanical Means using Dozer-In area of thorny jungle. Page No. 7,Sl. No.2.5 B. VOL-3 | ha | 173643.58 | 173643.58 | 0.03 | False | None | None | False | None | False | 5209.3074 | 0 | 2400473 | 71571 | None | code02 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work-In all kinds of soils Depth upto 3 m. Page No. 8,Sl. No.1.14..1,VOL-1 | Cum | 75.19 | 75.19 | 180.79 | False | None | None | False | None | False | 13593.6001 | 0 | 2400474 | 71571 | None | code03 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depth. sl.no-1.15.1, pg.no-8, volume-1. | Cum | 280.16 | 280.16 | 20.09 | False | None | None | False | None | False | 5628.4144 | 0 | 2400475 | 71571 | None | code04 | Earth work excavation by manual means for drains,canals, waste weir,draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading,caution lights, removal of stumps and other deleterious matter,excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m. sl.no-1.4.1, pg.no-5,volume-1. | Cum | 191.58 | 191.58 | 29.93 | False | None | None | False | None | False | 5733.9894 | 0 | 2400476 | 71571 | None | code05 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications, Sl.No 4.1/ Page No. 5-VOL-2 | Sqm | 97.85 | 97.85 | 152.0 | False | None | None | False | None | False | 14873.2 | 0 | 2400477 | 71571 | None | code06 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)-Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates. sl.no-2.1.2, pg.no-15. volume-1 | Cum | 5362.18 | 5362.18 | 10.61 | False | None | None | False | None | False | 56892.7298 | 0 | 2400478 | 71571 | None | code07 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (including cost of form work & excluding cost of steel reinforcement, dowel bars)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates sl.no-2.2.2.1, pg.no-15.Volume-I. FOOTING | Cum | 6651.04 | 6651.04 | 20.39 | False | None | None | False | None | False | 135614.7056 | 0 | 2400479 | 71571 | None | code08 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (including cost of form work & excluding cost of steel reinforcement, dowel bars)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates sl.no-2.2.2.1, pg.no-15.Volume-I. PEDASTAL | Cum | 6774.21 | 6774.21 | 2.84 | False | None | None | False | None | False | 19238.7564 | 0 | 2400480 | 71571 | None | code09 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (including cost of form work & excluding cost of steel reinforcement, dowel bars)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates sl.no-2.5.2, page no-17, volume-I. CURTAIN WALL | Cum | 7008.74 | 7008.74 | 6.15 | False | None | None | False | None | False | 43103.751 | 0 | 2400481 | 71571 | None | code10 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (including cost of form work & excluding cost of steel reinforcement, dowel bars)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates sl.no-2.5.2, page no-17, volume-I. PLINTH BEAM | Cum | 9557.37 | 9557.37 | 8.6892 | False | None | None | False | None | False | 83045.899404 | 0 | 2400482 | 71571 | None | code11 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. SL.No 1.9, Page No.7, volume-I | Cum | 210.12 | 210.12 | 110.58 | False | None | None | False | None | False | 23235.0696 | 0 | 2400483 | 71571 | None | code12 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. sl.no-1.8, page no-7,volume-I. | Cum | 414.06 | 414.06 | 122.92 | False | None | None | False | None | False | 50896.2552 | 0 | 2400484 | 71571 | None | code13 | Removal of Unserviceable Soil with Disposal upto a suitable distance as directed by the Engineer incharge of work, Sl. No. 3.1, Page No.15-volume-3. | Cum | 32.96 | 32.96 | 107.89 | False | None | None | False | None | False | 3556.0544 | 0 | 2400485 | 71571 | None | code14 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) Sl.no-5.4, page no-9,volume-2. | Cum | 5512.56 | 5512.56 | 1.2 | False | None | None | False | None | False | 6615.072 | 0 | 2400486 | 71571 | None | code15 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)-- Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates. SL.NO-2.1.4, PAGE NO-15, Volume-I. DPC | Cum | 5899.84 | 5899.84 | 0.05 | False | None | None | False | None | False | 294.992 | 0 | 2400487 | 71571 | None | code16 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (including cost of form work & excluding cost of steel reinforcement, dowel bars)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. sl.no-2.5.2, pg.no-17, volume-I. COLUMN, GROUND FLOOR | Cum | 10831.69 | 10831.69 | 8.55 | False | None | None | False | None | False | 92610.9495 | 0 | 2400488 | 71571 | None | code17 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)-- Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates. SL.NO-2.1.4, PAGE NO-15, Volume-I. DUMMY COLUMN, TERRACE FLOOR. | Cum | 10130.03 | 10130.03 | 1.98 | False | None | None | False | None | False | 20057.4594 | 0 | 2400489 | 71571 | None | code18 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (including cost of form work & excluding cost of steel reinforcement, dowel bars)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates sl.no-2.5.2, pg.no-17, volume-I. BEAM, GROUND FLOOR | Cum | 10194.53 | 10194.53 | 8.54 | False | None | None | False | None | False | 87061.2862 | 0 | 2400490 | 71571 | None | code19 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (including cost of form work & excluding cost of steel reinforcement, dowel bars)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. sl.no-2.5.2, pg.no-17, volume-I. LINTEL, GROUND FLOOR. | Cum | 10194.53 | 10194.53 | 2.09 | False | None | None | False | None | False | 21306.5677 | 0 | 2400491 | 71571 | None | code20 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (including cost of form work & excluding cost of steel reinforcement, dowel bars)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregat sl.no-2.5.2, pg.no-17, volume-I. CILLCONCRETE, GROUND FLOOR. | Cum | 9238.79 | 9238.79 | 0.65 | False | None | None | False | None | False | 6005.2135 | 0 | 2400492 | 71571 | None | code21 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. S.No. 6.32, Page No.17,Volume-2. GROUND FLOOR. | Sqm | 1231.88 | 1231.88 | 109.44 | False | None | None | False | None | False | 134816.9472 | 0 | 2400493 | 71571 | None | code22 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. S.No. 6.33, Page No.17, Volume-2. GROUND FLOOR | Sqm | 1092.83 | 1092.83 | 51.73 | False | None | None | False | None | False | 56532.0959 | 0 | 2400494 | 71571 | None | code23 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (including cost of form work & excluding cost of steel reinforcement, dowel bars)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. sl.no-2.5.2, pg.no-17, volume-I. SLAB, GROUND FLOOR. | Cum | 9557.37 | 9557.37 | 27.36 | False | None | None | False | None | False | 261489.6432 | 0 | 2400495 | 71571 | None | code24 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (including cost of form work & excluding cost of steel reinforcement, dowel bars)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. sl.no-2.5.2, pg.no-17, volume-I. CHAJJA, GROUND FLOOR. | Cum | 9238.79 | 9238.79 | 5.18 | False | None | None | False | None | False | 47856.9322 | 0 | 2400496 | 71571 | None | code25 | Providing Thermo-Mechanically Treated bars of grade Fe-550 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) Sl. No. 11.32 , Page No.84, Volume-2. GROUND FLOOR. | Kg | 94.76 | 94.76 | 10856.55 | False | None | None | False | None | False | 1028766.678 | 0 | 2400497 | 71571 | None | code26 | Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. Sl.No 12.13.2, Page No.100,Volume- 2. GROUND FLOOR. | Cum | 63451.09 | 63451.09 | 0.11 | False | None | None | False | None | False | 6979.6199 | 0 | 2400498 | 71571 | None | code27 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Sl. No.12.90, Page No. 112, Volume-2. GROUND FLOOR. | Sqm | 7457.2 | 7457.2 | 25.52 | False | None | None | False | None | False | 190307.744 | 0 | 2400499 | 71571 | None | code28 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size - 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Sl. No.12.85 Page No. 110, Volume-2. GROUND FLOOR. | Sqm | 5016.1 | 5016.1 | 5.04 | False | None | None | False | None | False | 25281.144 | 0 | 2400500 | 71571 | None | code29 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-35 mm thick both side commercial, Sl. No. 12.57.6,Page No. 106, Volume-2. GROUND FLOOR. | Sqm | 3032.32 | 3032.32 | 3.68 | False | None | None | False | None | False | 11158.9376 | 0 | 2400501 | 71571 | None | code30 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. sl.no-12.51, pg.no-105, volume-2. GROUND AND TERRACE FLOOR. | No | 1525.43 | 1525.43 | 1.0 | False | None | None | False | None | False | 1525.43 | 0 | 2400502 | 71571 | None | code31 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. SL.NO-12.58, PG.NO-107,VOLUME-2. | Nos | 112.27 | 112.27 | 1.0 | False | None | None | False | None | False | 112.27 | 0 | 2400503 | 71571 | None | code32 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete. SL.NO-12.62, PG.NO-107,VOLUME-2. | No | 180.25 | 180.25 | 2.0 | False | None | None | False | None | False | 360.5 | 0 | 2400504 | 71571 | None | code33 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 250x10mm, SL.NO-12.76.1, PG.NO-109,VOLUME-2. | Each | 347.11 | 347.11 | 2.0 | False | None | None | False | None | False | 694.22 | 0 | 2400505 | 71571 | None | code34 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5mm.(heavy type) Sl.no-12.75.1, pg.no-108,volume-2. | No | 207.03 | 207.03 | 4.0 | False | None | None | False | None | False | 828.12 | 0 | 2400506 | 71571 | None | code35 | Providing and fixing MS Hold fasts (SL. No 285,Page No.A-21, Basic Rate Rs. 32.00), volume-2. | Each | 32.96 | 32.96 | 6.0 | False | None | None | False | None | False | 197.76 | 0 | 2400507 | 71571 | None | code36 | Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms. Sl.no-12.64, pg.no-107.volume-2. | Nos | 48.41 | 48.41 | 1.0 | False | None | None | False | None | False | 48.41 | 0 | 2400508 | 71571 | None | code37 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding, Sl. No. 11.34A, Page No. 85,Volume-2. GROUND FLOOR. | Kg | 149.35 | 149.35 | 641.66 | False | None | None | False | None | False | 95831.921 | 0 | 2400509 | 71571 | None | code38 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.7, Page No.42, Volume-2. INTERNAL WALL, GROUND FLOOR. | Sqm | 320.33 | 320.33 | 254.64 | False | None | None | False | None | False | 81568.8312 | 0 | 2400510 | 71571 | None | code39 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl. No. 8.9, Page No.42, Volume-2. EXTERNAL WALL. GROUND FLOOR. | Sqm | 331.66 | 331.66 | 463.05 | False | None | None | False | None | False | 153575.163 | 0 | 2400511 | 71571 | None | code40 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)-- Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates. Page 15, Sl. No.2.1.4, Volume-I, FLOORING BED, GROUND FLOOR. | Cum | 5899.84 | 5899.84 | 15.14 | False | None | None | False | None | False | 89323.5776 | 0 | 2400512 | 71571 | None | code41 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : ** Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. sl.no-9.23, pg.no-63, volume-2. GROUND FLOOR. | Sqm | 1944.64 | 1944.64 | 33.36 | False | None | None | False | None | False | 64873.1904 | 0 | 2400513 | 71571 | None | code42 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm, sl.no-9.12.2, pg.no-60.volume-2. GROUND FLOOR. | Sqm | 1119.61 | 1119.61 | 113.94 | False | None | None | False | None | False | 127568.3634 | 0 | 2400514 | 71571 | None | code43 | Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. Sl.No 9.36, Page No.65, Volume-2. GROUND FLOOR. | Sqm | 1271.02 | 1271.02 | 25.18 | False | None | None | False | None | False | 32004.2836 | 0 | 2400515 | 71571 | None | code44 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Sl.No 8.51, Page No.50, Volume-2. GROUND, TERRACE FLOOR | Sqm | 85.49 | 85.49 | 518.5 | False | None | None | False | None | False | 44326.565 | 0 | 2400516 | 71571 | None | code45 | Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.33.1, Page No.46, Volume-2. CEILING, GROUND FLOOR. | Sqm | 121.54 | 121.54 | 263.86 | False | None | None | False | None | False | 32069.5444 | 0 | 2400517 | 71571 | None | code46 | Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.33.1, Page No.46, Volume-2. INTERNAL WALL, GROUND FLOOR. | Sqm | 121.54 | 121.54 | 254.64 | False | None | None | False | None | False | 30948.9456 | 0 | 2400518 | 71571 | None | code47 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.30, Page No.46, Volume-2. EXTERNAL WALL,GROUND FLOOR. | Sqm | 140.08 | 140.08 | 463.05 | False | None | None | False | None | False | 64864.044 | 0 | 2400519 | 71571 | None | code48 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.29, Page No.45,Volume-2. GROUND FLOOR. | Sqm | 214.24 | 214.24 | 23.15 | False | None | None | False | None | False | 4959.656 | 0 | 2400520 | 71571 | None | code49 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.41,Page No.48, Volume-2. GROUND FLOOR. | Sqm | 133.9 | 133.9 | 30.56 | False | None | None | False | None | False | 4091.984 | 0 | 2400521 | 71571 | None | code50 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge.Sl.No 8.55.1, Page No.51, Volume-2. GROUND FLOOR. | Sqm | 42.23 | 42.23 | 9.56 | False | None | None | False | None | False | 403.7188 | 0 | 2400522 | 71571 | None | code51 | Polishing on wood work with ready mixed wax polish of approved brand and manufacture : New work to give an even surface including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.sl.no-8.47, pg.no-49. GROUND FLOOR. | Sqm | 110.21 | 110.21 | 9.56 | False | None | None | False | None | False | 1053.6076 | 0 | 2400523 | 71571 | None | code52 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Sl.No 11.28, Page No.83, Volume-2.GROUND FLOOR. | Kg | 515.0 | 515.0 | 52.5 | False | None | None | False | None | False | 27037.5 | 0 | 2400524 | 71571 | None | code53 | Providing and fixing ion wall face unplasticised Rigid PVC rain water pipes confirming to IS :13592 Type A,including jointing with seal ring confirming to IS:5382,leaving 10mm gap for thermal expansion,(i) Single socketed pipes 100mm diameter.item no-13.48, volume-2. (1 st Addenda for vol.1,2 & 3 schedule of rates w.e.f 21-04-2022) | m | 260.59 | 260.59 | 30.0 | False | None | None | False | None | False | 7817.7 | 0 | 2400525 | 71571 | None | code54 | Lettering with black Japan paint of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. SL.NO-8.49, PG.NO-49, VOLUME-2. GROUND FLOOR. | cm | 3.09 | 3.09 | 500.0 | False | None | None | False | None | False | 1545.0 | 0 | 2400526 | 71571 | None | code55 | Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in Granite, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.SL.NO-10.4, PG.NO-69, VOLUME-2. GROUND FLOOR. | m | 466.59 | 466.59 | 8.4 | False | None | None | False | None | False | 3919.356 | 0 | 2400527 | 71571 | None | code56 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)-- Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates. Page 15, Sl. No.2.1.4, Volume-I, TERRACE FLOOR. | Cum | 5958.84 | 5958.84 | 13.68 | False | None | None | False | None | False | 81516.9312 | 0 | 2400528 | 71571 | None | code57 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.7, Page No.42, Volume-2. Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineerin-Charge. Sl. No. 8.12, Page No.43, Volume-2. TERRACE FLOOR. | Sqm | 323.53 | 323.53 | 182.37 | False | None | None | False | None | False | 59002.1661 | 0 | 2400529 | 71571 | None | code58 | INTERNAL WIRING & POWER POINTS: PVC Conduit and its Accessories: Concealed Conduit System: Supplying heavy gauge PVC conduit pipe … mm dia confirming to IS 2509 with suitable size bends, metal / PVC junction boxes adhesive paste etc. and running before Concreting the Slab. The Conduit should be tied to the reenforcement Rods by using binding wires and the unused ways of Junction boxes should be covered using PVC End enclosures .run with 18 SWG GI finish wire wherever it is necessory: 19/20mm Dia 2mm Thick, SL.NO-1.2.1. | m | 61.0 | 61.0 | 80.0 | False | None | None | False | None | False | 4880.0 | 0 | 2400530 | 71571 | None | code59 | INTERNAL WIRING & POWER POINTS: PVC Conduit and its Accessories: Concealed Conduit System: Supplying heavy gauge PVC conduit pipe … mm dia confirming to IS 2509 with suitable size bends, metal / PVC junction boxes adhesive paste etc. and running before Concreting the Slab. The Conduit should be tied to the reenforcement Rods by using binding wires and the unused ways of Junction boxes should be covered using PVC End enclosures .run with 18 SWG GI finish wire wherever it is necessory; 25mm dia 2mm Thick, SL.NO-1.2.2. | m | 70.0 | 70.0 | 90.0 | False | None | None | False | None | False | 6300.0 | 0 | 2400531 | 71571 | None | code60 | Supplying heavy gauge PVC conduit pipe … mm dia confirming to IS 2509 with suitable size bends, metal / PVC junction boxes adhesive paste etc. by groove cutting in the wall and fixing by bracing U or J hooks and plastering upto wall surface and .run with 18 SWG GI finish wire wherever it is necessory: 19/20mm Dia 2mm Thick, SL.NO-1.3.1. | m | 75.0 | 75.0 | 80.0 | False | None | None | False | None | False | 6000.0 | 0 | 2400532 | 71571 | None | code61 | Supplying heavy gauge PVC conduit pipe … mm dia confirming to IS 2509 with suitable size bends, metal / PVC junction boxes adhesive paste etc. by groove cutting in the wall and fixing by bracing U or J hooks and plastering upto wall surface and .run with 18 SWG GI finish wire wherever it is necessory; 25mm dia 2mm Thick, SL.NO-1.3.2. | m | 80.0 | 80.0 | 60.0 | False | None | None | False | None | False | 4800.0 | 0 | 2400533 | 71571 | None | code62 | Supplying and fixing PVC/ Metal Conduit Deep Junction Boxes: 19/20 mm Deep Junction Box, SL.NO-1.5.1. | Each | 49.0 | 49.0 | 15.0 | False | None | None | False | None | False | 735.0 | 0 | 2400534 | 71571 | None | code63 | Supplying and fixing PVC/ Metal Conduit Deep Junction Boxes: 25 mm Deep Junction Box, SL.NO-1.5.2. | Each | 51.0 | 51.0 | 10.0 | False | None | None | False | None | False | 510.0 | 0 | 2400535 | 71571 | None | code64 | Supplying and fixing PVC/ Metal Conduit Deep Junction Boxes; 32 mm deep Junction Box. SL.NO-1.5.3. | Each | 69.0 | 69.0 | 5.0 | False | None | None | False | None | False | 345.0 | 0 | 2400536 | 71571 | None | code65 | Supplying and fixing PVC Casing and capping on the wall or ceiling using materials like bend , screws at an interval 0f 300 mm etc: 20 mm, SL.NO-1.8.1. | m | 27.0 | 27.0 | 65.0 | False | None | None | False | None | False | 1755.0 | 0 | 2400537 | 71571 | None | code66 | Supplying and fixing PVC Casing and capping on the wall or ceiling using materials like bend , screws at an interval 0f 300 mm etc: 25 mm, SL.NO-1.8.2. | m | 28.0 | 28.0 | 45.0 | False | None | None | False | None | False | 1260.0 | 0 | 2400538 | 71571 | None | code67 | Supplying and fixing PVC Casing and capping on the wall or ceiling using materials like bend , screws at an interval 0f 300 mm etc: 32 mm, SL.NO-1.8.3. | m | 41.0 | 41.0 | 15.0 | False | None | None | False | None | False | 615.0 | 0 | 2400539 | 71571 | None | code68 | Supplying PVC /GI flexible conduit pipe …. Mm dia fixing on surface cover inverted tapared wodden plugs or phill plugs or rawl plugs and clamped using heavy guage saddles in an interval of 300 mm using NF screws and on the eaiter end of the pipe terminated properly: 20 mm, SL.NO-1.9.1. | m | 25.0 | 25.0 | 185.0 | False | None | None | False | None | False | 4625.0 | 0 | 2400540 | 71571 | None | code69 | Supplying PVC /GI flexible conduit pipe …. Mm dia fixing on surface cover inverted tapared wodden plugs or phill plugs or rawl plugs and clamped using heavy guage saddles in an interval of 300 mm using NF screws and on the eaiter end of the pipe terminated properly: 25 mm, SL.NO-1.9.2. | m | 31.0 | 31.0 | 265.0 | False | None | None | False | None | False | 8215.0 | 0 | 2400541 | 71571 | None | code70 | Supply & Fixing of Metal fan box with round Hook, SL.NO-1.12. | Each | 163.0 | 163.0 | 10.0 | False | None | None | False | None | False | 1630.0 | 0 | 2400542 | 71571 | None | code71 | Wires & Cables: Point wiring using copper wire without Switch: Supplying and wiring adopting loop system in existing PVC conduit/casing capping, using copper FRLS PVC insulated multi strand 2 x 1.5 sq.mm copper wire without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/pvc round block complete for each outlet.: Make : KEI / Polycab/ Finolex: Short point upto 3 Mtd. From Tapping point to outlet via switch box. SL.NO-2.2.1. | Point | 251.0 | 251.0 | 6.0 | False | None | None | False | None | False | 1506.0 | 0 | 2400543 | 71571 | None | code72 | Wires & Cables: Point wiring using copper wire without Switch: Supplying and wiring adopting loop system in existing PVC conduit/casing capping, using copper FRLS PVC insulated multi strand 2 x 1.5 sq.mm copper wire without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/pvc round block complete for each outlet.: Make : KEI / Polycab/ Finolex: Medium point above 3 Mts upto 6 Mts. From tapping point to outlet via switch box. SL,NO-2.2.2. | Point | 361.0 | 361.0 | 8.0 | False | None | None | False | None | False | 2888.0 | 0 | 2400544 | 71571 | None | code73 | Wires & Cables: Point wiring using copper wire without Switch: Supplying and wiring adopting loop system in existing PVC conduit/casing capping, using copper FRLS PVC insulated multi strand 2 x 1.5 sq.mm copper wire without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/pvc round block complete for each outlet.: Make : KEI / Polycab/ Finolex: Two outlet in a row above 3 Mts upto 6 Mts, from tapping point to outlet via switch box. SL.NO-2.2.4. | Point | 671.0 | 671.0 | 3.0 | False | None | None | False | None | False | 2013.0 | 0 | 2400545 | 71571 | None | code74 | Wires & Cables: Point wiring using copper wire without Switch: Supplying and wiring adopting loop system in existing PVC conduit/casing capping, using copper FRLS PVC insulated multi strand 2 x 1.5 sq.mm copper wire without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/pvc round block complete for each outlet.: Make : KEI / Polycab/ Finolex: Three outlet in a row, above 6 Mts. Upto 10 Mts. From tapping point to outlet via switch box. SL.NO-2.2.5. | Point | 979.0 | 979.0 | 2.0 | False | None | None | False | None | False | 1958.0 | 0 | 2400546 | 71571 | None | code75 | Wiring for Lighting/ Power Circuit using one of PVC insulated 1100V grade, multistrand Copper conductor 1C cable in open or Concealed system of Wiring: 1.5 Sqmm, SL.NO-2.3.2. | m | 26.0 | 26.0 | 160.0 | False | None | None | False | None | False | 4160.0 | 0 | 2400547 | 71571 | None | code76 | Wiring for Lighting/ Power Circuit using one of PVC insulated 1100V grade, multistrand Copper conductor 1C cable in open or Concealed system of Wiring: 2.5Sqmm, SL.NO-2.3.3. | m | 40.0 | 40.0 | 80.0 | False | None | None | False | None | False | 3200.0 | 0 | 2400548 | 71571 | None | code77 | Wiring for Lighting/ Power Circuit using one of PVC insulated 1100V grade, multistrand Copper conductor 1C cable in open or Concealed system of Wiring: 4Sqmm, SL.NO-2.3.4. | m | 59.0 | 59.0 | 30.0 | False | None | None | False | None | False | 1770.0 | 0 | 2400549 | 71571 | None | code78 | Switches Sockets and Accessories: Supplying and Flush mounting Powder coated / galvanised metal box suitable for mounting modular switch plates . The Box should be firmly flush mounted after due groove cutting in brick / Stone / C.C wall: Make : Anchor / Schneider / Legrand: 1-3 way , SL.NO-3.4.1. | Each | 123.0 | 123.0 | 22.0 | False | None | None | False | None | False | 2706.0 | 0 | 2400550 | 71571 | None | code79 | Switches Sockets and Accessories: Supplying and Flush mounting Powder coated / galvanised metal box suitable for mounting modular switch plates . The Box should be firmly flush mounted after due groove cutting in brick / Stone / C.C wall: Make : Anchor / Schneider / Legrand: 16 way, SL.NO-3.4.6. | Each | 354.0 | 354.0 | 6.0 | False | None | None | False | None | False | 2124.0 | 0 | 2400551 | 71571 | None | code80 | Supplying and fixing Superior Quality modular switch mounting poly carbonate plate with necessory supporting back plate with required no. of machine screws , bolts nuts etc. complte on existing metal / PVC box: 1-3 way, SL.NO-3.5.1. | Each | 152.0 | 152.0 | 22.0 | False | None | None | False | None | False | 3344.0 | 0 | 2400552 | 71571 | None | code81 | Supplying and fixing Superior Quality modular switch mounting poly carbonate plate with necessory supporting back plate with required no. of machine screws , bolts nuts etc. complte on existing metal / PVC box: 16 way , SL.NO-3.5.6. | Each | 403.0 | 403.0 | 6.0 | False | None | None | False | None | False | 2418.0 | 0 | 2400553 | 71571 | None | code82 | Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate : 6 Amp one way , SL.NO-3.6.1. | Each | 88.0 | 88.0 | 32.0 | False | None | None | False | None | False | 2816.0 | 0 | 2400554 | 71571 | None | code83 | Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate : 6 Amps socket, SL.NO-3.6.3. | Each | 162.0 | 162.0 | 21.0 | False | None | None | False | None | False | 3402.0 | 0 | 2400555 | 71571 | None | code84 | Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate : Stepped Fan Regulator, SL.NO-3.6.4. | Each | 313.0 | 313.0 | 5.0 | False | None | None | False | None | False | 1565.0 | 0 | 2400556 | 71571 | None | code85 | Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate : 6 Amps Bell Push, SL.NO-3.7.9. | Each | 159.0 | 159.0 | 2.0 | False | None | None | False | None | False | 318.0 | 0 | 2400557 | 71571 | None | code86 | Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate : 32 Amps DP Switch, SL.NO-3.7.10. | Each | 375.0 | 375.0 | 3.0 | False | None | None | False | None | False | 1125.0 | 0 | 2400558 | 71571 | None | code87 | LUMINERIES & LIGHT FIXTURES & ACCESSORIES: Make : Panasonic/Phillips / Crompton: Led Light Fixture 2 feet - 9/10 W, SL.NO-11.3.1. | Each | 496.0 | 496.0 | 8.0 | False | None | None | False | None | False | 3968.0 | 0 | 2400559 | 71571 | None | code88 | LUMINERIES & LIGHT FIXTURES & ACCESSORIES: Make : Panasonic/Phillips / Crompton: Led Light Fixture 4 feet - 20/22 W, SL.NO-11.3.2. | Each | 740.0 | 740.0 | 6.0 | False | None | None | False | None | False | 4440.0 | 0 | 2400560 | 71571 | None | code89 | LUMINERIES & LIGHT FIXTURES & ACCESSORIES: Make : Panasonic/Phillips / Crompton: Supply of recess mounted rolling type LED square or round Light 12 watta, SL.NO-11.5.2. | Each | 835.0 | 835.0 | 3.0 | False | None | None | False | None | False | 2505.0 | 0 | 2400561 | 71571 | None | code90 | PANEL & DISTRIBUTION BOARDS: Distribution boards: Supplying and fixing regular MCB distribution Boards on Wall / wood board /flush mounting using required clamps bolts nuts etc with provision for fixing suitable type capacity MCB single phase / 3 phase / single door with powder coated paiting : Double Door: 6Way TP &N, SL.NO-5.18.12. | Nos | 3735.0 | 3735.0 | 3.0 | False | None | None | False | None | False | 11205.0 | 0 | 2400562 | 71571 | None | code91 | PANEL & DISTRIBUTION BOARDS: Distribution boards: Supplying and fixing regular MCB distribution Boards on Wall / wood board /flush mounting using required clamps bolts nuts etc with provision for fixing suitable type capacity MCB single phase / 3 phase / single door with powder coated paiting : Double Door: 8Way TP &N, SL.NO-5.18.13. | Nos | 4136.0 | 4136.0 | 2.0 | False | None | None | False | None | False | 8272.0 | 0 | 2400563 | 71571 | None | code92 | PANEL & DISTRIBUTION BOARDS: Distribution boards: Supplying and fixing regular MCB distribution Boards on Wall / wood board /flush mounting using required clamps bolts nuts etc with provision for fixing suitable type capacity MCB single phase / 3 phase / single door with powder coated paiting : Double Door; 12Way TP &N, SL.NO-5.18.14. | Nos | 5744.0 | 5744.0 | 1.0 | False | None | None | False | None | False | 5744.0 | 0 | 2400564 | 71571 | None | code93 | Supplying fixing & wiring earth leakage miniature circuit breaker (ELMCB) 240 / 450 V up to 300mA sensitivity on Existing / panel Board: 16 - 25 Amps 2 pole, SL.NO-5.20.1. | Nos | 2536.0 | 2536.0 | 3.0 | False | None | None | False | None | False | 7608.0 | 0 | 2400565 | 71571 | None | code94 | Supplying fixing & wiring earth leakage miniature circuit breaker (ELMCB) 240 / 450 V up to 300mA sensitivity on Existing / panel Board: 32 - 40 Amps 2 pole. SL.NO-5.20.2. | Nos | 2652.0 | 2652.0 | 2.0 | False | None | None | False | None | False | 5304.0 | 0 | 2400566 | 71571 | None | code95 | Supplying fixing & wiring earth leakage miniature circuit breaker (ELMCB) 240 / 450 V up to 300mA sensitivity on Existing / panel Board: 32 - 40 Amps 4 pole. SL.NO-5.20.3. | Nos | 2826.0 | 2826.0 | 1.0 | False | None | None | False | None | False | 2826.0 | 0 | 2400567 | 71571 | None | code96 | Supplying and Fixing miniature circuit breakers on existing MCB distribution boards using necessory fixing materials & C type curve indicator ON OFF energy cross 3 with short circuit breaking capacity of 10 K and complete wiring as required confirming to IEC 60898: 5 - 32 Amp SP, SL.NO-5.17.1. | Nos | 523.0 | 523.0 | 8.0 | False | None | None | False | None | False | 4184.0 | 0 | 2400568 | 71571 | None | code97 | Supplying and Fixing miniature circuit breakers on existing MCB distribution boards using necessory fixing materials & C type curve indicator ON OFF energy cross 3 with short circuit breaking capacity of 10 K and complete wiring as required confirming to IEC 60898: 40 - 63 Amps SP, SL.NO-5.17.2. | Nos | 726.0 | 726.0 | 1.0 | False | None | None | False | None | False | 726.0 | 0 | 2400569 | 71571 | None | code98 | Supplying and Fixing miniature circuit breakers on existing MCB distribution boards using necessory fixing materials & C type curve indicator ON OFF energy cross 3 with short circuit breaking capacity of 10 K and complete wiring as required confirming to IEC 60898: 5 - 32 Amp DP, SL.NO-5.17.4. | Nos | 1103.0 | 1103.0 | 2.0 | False | None | None | False | None | False | 2206.0 | 0 | 2400570 | 71571 | None | code99 | Supplying and Fixing miniature circuit breakers on existing MCB distribution boards using necessory fixing materials & C type curve indicator ON OFF energy cross 3 with short circuit breaking capacity of 10 K and complete wiring as required confirming to IEC 60898: 40 - 63 Amp DP, SL.NO-5.17.6. | Nos | 1376.0 | 1376.0 | 2.0 | False | None | None | False | None | False | 2752.0 | 0 | 2400571 | 71571 | None | code100 | Supplying and Fixing miniature circuit breakers on existing MCB distribution boards using necessory fixing materials & C type curve indicator ON OFF energy cross 3 with short circuit breaking capacity of 10 K and complete wiring as required confirming to IEC 60898: 40 - 63 Amp TPN, SL.NO-5.17.9. | Nos | 2399.0 | 2399.0 | 1.0 | False | None | None | False | None | False | 2399.0 | 0 | 2400572 | 71571 | None | code101 | SERVICE MAINS & WORK UNDER UG CABLE , EARTHING: Supplying Fixing and Wiring earth electrode for grounding of lifts,Xmer, DG Sets etc using 40mm dia 2.9mm thick, 2.5mtr long GI pipe with GI funnel with mesh & suitable size reducer fixed on the top of Electrode. The funnel should be enclosed in a cc chamber of 400x400x400 with a cast iron cover. The Earth electrode shall have staggered holes of 12mm dia & electrode shoulde be covered 150mm around with alternate layers of salt & charcoal from the bottom of the CC Chamber. The connection from the electrode is to be established throgh GI strip using GI bolts & nuts. | No | 4150.0 | 4150.0 | 1.0 | False | None | None | False | None | False | 4150.0 | 0 | 2400573 | 71571 | None | code102 | SERVICE MAINS & WORK UNDER UG CABLE , EARTHING: Supplying Fixing and Wiring earth electrode for grounding of lifts,Xmer, DG Sets etc using 40mm dia 2.9mm thick, 2.5mtr long GI pipe with GI funnel with mesh & suitable size reducer fixed on the top of Electrode. The funnel should be enclosed in a cc chamber of 400x400x400 with a cast iron cover. The Earth electrode shall have staggered holes of 12mm dia & electrode shoulde be covered 150mm around with alternate layers of salt & charcoal from the bottom of the CC Chamber. The connection from the electrode is to be established throgh GI strip using GI bolts & nuts.: GI Strip: 25 x 3 mm G.I strip. SL.NO-6.3.1. | m | 75.0 | 75.0 | 10.0 | False | None | None | False | None | False | 750.0 | 0 | 2400574 | 71571 | None | code103 | SERVICE MAINS & WORK UNDER UG CABLE , EARTHING: Supplying Fixing and Wiring earth electrode for grounding of lifts,Xmer, DG Sets etc using 40mm dia 2.9mm thick, 2.5mtr long GI pipe with GI funnel with mesh & suitable size reducer fixed on the top of Electrode. The funnel should be enclosed in a cc chamber of 400x400x400 with a cast iron cover. The Earth electrode shall have staggered holes of 12mm dia & electrode shoulde be covered 150mm around with alternate layers of salt & charcoal from the bottom of the CC Chamber. The connection from the electrode is to be established throgh GI strip using GI bolts & nuts.: GI Strip: 600x600x3 GI Plate. SL.NO-6.3.5. | Each | 760.0 | 760.0 | 2.0 | False | None | None | False | None | False | 1520.0 | 0 | 2400575 | 71571 | None | code104 | SERVICE MAINS & WORK UNDER UG CABLE , EARTHING: Supplying Fixing and Wiring earth electrode for grounding of lifts,Xmer, DG Sets etc using 40mm dia 2.9mm thick, 2.5mtr long GI pipe with GI funnel with mesh & suitable size reducer fixed on the top of Electrode. The funnel should be enclosed in a cc chamber of 400x400x400 with a cast iron cover. The Earth electrode shall have staggered holes of 12mm dia & electrode shoulde be covered 150mm around with alternate layers of salt & charcoal from the bottom of the CC Chamber. The connection from the electrode is to be established throgh GI strip using GI bolts & nuts.: Cu. Strip: 25 x 3 mm , SL.NO-6.3.6. | m | 505.0 | 505.0 | 20.0 | False | None | None | False | None | False | 10100.0 | 0 | 2400576 | 71571 | None | code105 | SERVICE MAINS & WORK UNDER UG CABLE , EARTHING: Supplying Fixing and Wiring earth electrode for grounding of lifts,Xmer, DG Sets etc using 40mm dia 2.9mm thick, 2.5mtr long GI pipe with GI funnel with mesh & suitable size reducer fixed on the top of Electrode. The funnel should be enclosed in a cc chamber of 400x400x400 with a cast iron cover. The Earth electrode shall have staggered holes of 12mm dia & electrode shoulde be covered 150mm around with alternate layers of salt & charcoal from the bottom of the CC Chamber. The connection from the electrode is to be established throgh GI strip using GI bolts & nuts.: Cu. Strip: 600x600x3 Cu. Plate, SL.NO-6.3.10. | Each | 6900.0 | 6900.0 | 1.0 | False | None | None | False | None | False | 6900.0 | 0 | 2400577 | 71571 | None | code106 | Supply & Fixing of Heavy Duty Cable Glands Suitable For UG Cable of 1.1KV Class (metal Only): 25mm Dia, SL.NO-6.11.2. | Nos | 84.0 | 84.0 | 3.0 | False | None | None | False | None | False | 252.0 | 0 | 2400578 | 71571 | None | code107 | Supply & Fixing of Heavy Duty Cable Glands Suitable For UG Cable of 1.1KV Class (metal Only): 63mm Dia, SL.NO-6.11.6. | Nos | 388.0 | 388.0 | 2.0 | False | None | None | False | None | False | 776.0 | 0 | 2400579 | 71571 | None | code108 | FANS & AIR CONDITIONERS: Make Fans : Crompton / Usha / Anchor: Supplying exhaust fan 0f 1440 RPM of300 mm (12") size with bracket blades complte for light duty suitable to operate on 230V 50 Hz AC Supply | Each | 1542.0 | 1542.0 | 3.0 | False | None | None | False | None | False | 4626.0 | 0 | 2400580 | 71571 | None | code109 | FANS & AIR CONDITIONERS: Make Fans : Crompton / Usha / Anchor: Supplying capacitor type ceiling Fan complete with down rod blades shackle ,canopies etc. for operation on 230 Vots 50 cycles ,single phase AC supply confirming to ISS -374-1979 with double ball bearing system: 48 " Sweep: Economy model. SL.NO-6.3.1. | Each | 2085.0 | 2085.0 | 1.0 | False | None | None | False | None | False | 2085.0 | 0 | 2400581 | 71571 | None | code110 | NON SR: Table dimension : 2400mm x750mmx750mm. Providing and Fabricating Court hall table with 19mm ply finished with 4mm thick approved Veneer Melamine finished. Table top: 40mm thick table top to be formed out 2 layers of 19mm thick ply and to be finished with 4mm thick approved Veneer and melamine polished. The edge of the table to be provided with approved timber beading to form 50mm thick fascia formed to shape finished with approved Melamine polish to match the veneer. The top to house cable trough/cable pop up box for cable management with 19mm thick ply openable as per details, complete as per detail dwg. Base: The base of the table shall consist of 19mm commercial ply finished with 4mm thick veneer of approved make & shade over sal wood-50x50mm frame work. Cost to include providing & fixing 6x6mm thick Aluminium beading, complete as per the drawing & instructions of the Engineer-in-charge. (Approved rate of VIP Guest house Raichur) | m | 10027.97 | 10027.97 | 2.4 | False | None | None | False | None | False | 24067.128 | 0 | 2400582 | 71571 | None | code111 | Students/Visitor Chairs:Supplying and arranging in position chairs for class room Dimensions (L x W x H): 475mm x 400mm x825 mm; Product Weight: 5.4 kg Material: Stainless Steel and PU Leather Color: Black Seat Type: Water Fall Seat It comes with silver coating and armrest with padding for an attractive look.satisfying various parameters such as quality of Raw Material, Finish, Polish, Sturdiness and Durability to ensure that these products are in conformance with Quality Standard (approved rate Visual Arts) | Nos | 5084.75 | 5084.75 | 3.0 | False | None | None | False | None | False | 15254.25 | 0 | 2400583 | 71571 | None | code112 | Desk for Class room: Providing and arranging Desk of Height 750 mm, length 1200mm and width of 400 mm made out of combination of 25 mm ply board and HDF Boards & Laminated Wood, providing supports where ever required. Laminated film of approved colour & shade which is fused with an atractive decorative film which is abrasion proof. The top surface is fused to high density fibre board which forms the supportive core (HDF) which also includes undersurface dampness impending stabalization film which ensures and preserves high structural stability.satisfying various parameters such as quality of Raw Material, Finish, Polish, Sturdiness and Durability to ensure that these products are in conformance with Quality Standard (approved Rate visual Arts) | Nos | 11864.41 | 11864.41 | 3.0 | False | None | None | False | None | False | 35593.23 | 0 | 2400584 | 71571 | None | code113 | Writing board : supplying and installing of writing board of size 2000mm L x 1000mm H writing board in position on wall surface @ required height having aluminium beading allround the board(approved rate Visual Arts) | Nos | 5084.75 | 5084.75 | 1.0 | False | None | None | False | None | False | 5084.75 | 0 |
|