createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1705660070788
version11
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee3220.00
emd200000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose13-02-2024 16:00:00
tenderQueryClose12-02-2024 16:00:00
technicalBidOpen14-02-2024 16:30:00
publishedDate02-02-2024 16:11:11
publishedByPostPWD_EE_DIV_SRS
publishedByUserKPE13867 - N K KURANDKAR
bidValidityPeriod90
noOfCalls1
preBidMeetingDate08-02-2024 11:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonEr Ramesh B
splitEmdRequiredYnTrue
emdBankGuarantee100000.00
emdCash100000.00
bgValidityPeriod135
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber9480138387
tenderSupplierListNone
tenderSchedule
createdTs1705660070822
version7
createdDateNone
modifiedDateNone
tenderNumberPWD/2023-24/BD/WORK_INDENT6249
titleCONSTRUCTION OF TWO CLASSROOMS,TWO LABORATORIES AND TWO TOILETS FOR MARIKAMBA GOVT PU COLLEGE AT SIRSI TALUK,UK DISTRICT
descriptionCONSTRUCTION OF TWO CLASSROOMS,TWO LABORATORIES AND TWO TOILETS FOR MARIKAMBA GOVT PU COLLEGE AT SIRSI TALUK,UK DISTRICT
categoryWORKS
categoryTextWorks
ecv12852196.24
deptNamePublic Works Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location1683
locationNamePWD Division Office Sirsi
provisionalAmount15800000.0
groupOverheadTotal0.0
fileNumberPWD/2023-24/SRS/NABARDRIDF28/BD
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17056600710000NoneNoneBuildingsCONSTRUCTION OF TWO LABORATORIES AT FIRST FLOOR6263771.05
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
223275965297NoneVOL 2,6.7,P-13Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer in charge of work ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Cum9014.539014.53102.02FalseNoneNoneFalseNoneFalse919662.35060
223276065297Nonevol 1,2.5.2,P-16Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Cum13105.7113105.7113.18FalseNoneNoneFalseNoneFalse172733.25780
223276165297Nonevol 1,2.5.2,P-16Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Cum12339.312339.326.89FalseNoneNoneFalseNoneFalse331803.7770
223276265297NoneVOL 1,2.5.2,P-16Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Cum11572.8811572.8855.81FalseNoneNoneFalseNoneFalse645882.43280
223276365297Nonevol 2,8.2.2,P-41Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Sqm315.6315.6435.31FalseNoneNoneFalseNoneFalse137383.8360
223276465297Nonevol 2,8.8,P-42Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Sqm419.68419.68644.28FalseNoneNoneFalseNoneFalse270391.43040
223276565297Nonevol 2,9.21.2,P-62Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).600 *600 ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Sqm1400.431400.43282.4FalseNoneNoneFalseNoneFalse395481.4320
223276665297Nonevol 2,9.24,P-63Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well ascurvi linear portions of the building all complete as per the architectural drawings with 18 mm thick stone slabover 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Sqm3226.183226.18205.85FalseNoneNoneFalseNoneFalse664109.1530
223276765297Nonevol 2,8.51,P-50Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Sqm113.12113.12679.06FalseNoneNoneFalseNoneFalse76815.26720
223276865297Nonevol 2,8.54.2,P-50Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Sqm124.43124.431094.72FalseNoneNoneFalseNoneFalse136216.00960
223276965297Nonevol 2,8.30,P-46Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost ofmaterials, labour complete as per specifications and as per directions of Engineer-in-charge ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Sqm196.83196.83929.92FalseNoneNoneFalseNoneFalse183036.15360
223277065297Nonevol 2,12.13.1,P-100Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled includingmaking plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.CUBIC METER111779.53111779.530.4FalseNoneNoneFalseNoneFalse44711.8120
223277165297Nonevol 2,12.18,P-100Providing and fixing in position fully panelled Matti/Nandi wood shutters for doors with, stiles and rails of 35mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures ) ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Sqm7438.777438.7715.12FalseNoneNoneFalseNoneFalse112474.20240
223277265297Nonevol 2,8.55.1,P-50Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hardand soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge. ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Sqm63.3563.3530.24FalseNoneNoneFalseNoneFalse1915.7040
223277365297Nonevol 2,8.41,P-48Painting with synthetic enamel paint of approved brand andmanufacture of required colour to give an even shade :Two coats onnew work over an under coat of suitable shade with ordinary paintof approved brand and manufacture after thoroughly brooming thesurface to remove all dirt, dust, mortar drops and foreign matterincluding preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directionsof Engineer-in-charge. ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Sqm188.91188.9130.24FalseNoneNoneFalseNoneFalse5712.63840
223277465297Nonevol 2,12.84,P-108Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6 PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets -grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 44mm width x 40mmheight with reinforcement of 1mm thickness and Sash with overall size of 27mm X 53mm with UPVC honeycomb structure inside in lieu of GI reinforcement. Coextruded Glazing bead for fixing of glass shall be of size 9.5mm x 21.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with Crescent Locks. Wall thickness of frame & sash shall be of 2 mm.Maximum possible size 1219mm x 1219mm. The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Sqm5682.025682.0221.6FalseNoneNoneFalseNoneFalse122731.6320
223277565297Nonevol 2,12.85,P-109Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced withGalvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness.Louver clip in Aluminium (powder coated in white) will be used on theframe along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x1000mm.(The cost is inclusive of all fixtures and separate charges for" ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Sqm6469.336469.331.44FalseNoneNoneFalseNoneFalse9315.83520
223277665297Nonevol 2,11.28.2,P-83Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Kg639.13639.1360.48FalseNoneNoneFalseNoneFalse38654.58240
223277765297Nonevol2,15.1,P-133Providing and laying water proofing treatment to the Roof with PU basedsingle component elastomeric pure polyurethane based coating onNew errace/ Chajjas/Sunken portion of WC:Bathroom, cold applied PUwaterproofing membrane that is highly elastic with elongation greaterthan 400% and tensile strength greater than 2MPa as per ASTM D412.The waterproofing membrane to be applied in 2coats @ 1.6kg per m2to achieve final DFT (dry film thickness) of 1mm including prime coat ofepoxy primer @150 g per m2 and protection with 120gsm Geo-textileover the waterproofing membrane. The finished cost to include surfacepreparation, making coving at Junction, Bore Packing, treatment ofconstruction joints completely as per specification & with a 10 yearswarranty on product & work from certified manufacturers as per the ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Sqm842.74842.74198.0FalseNoneNoneFalseNoneFalse166862.520
223277865297Nonevol2,14.11.1,P-134Providing and fixing white vitreous china laboratory sink with C.I.brackets,C.P. brass chain with rubber plug, 40 mm C.P brass wasteand 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good thewall wherever required :14.11.1 Size 450x300x150 mm ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.No4421.864421.8620.0FalseNoneNoneFalseNoneFalse88437.20
223277965297Nonevol 1,2.11(a),P-18Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. FOR BUILDINGS ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Kg101.2101.211020.87FalseNoneNoneFalseNoneFalse1115312.0440
223278065297Nonevol 2,11.34B,P-86Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Kg207.01207.01642.6FalseNoneNoneFalseNoneFalse133024.6260
223278165297Nonevol 2,11.16.2,P-82Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications andas per directions of the Engineer-in-Charge. ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Kg160.63160.631110.0FalseNoneNoneFalseNoneFalse178299.30
223278265297Nonevol 2,7.38,P-26Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal,complete upto any pitch in horizontal/ vertical or curved surfaces,excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Sqm642.52642.52400.0FalseNoneNoneFalseNoneFalse257008.00
223278365297Nonevol 2,19.27.1,P-189Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material to the appropriate disposal area as per direction of Engineer-in-charge.G.S. Sheet ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Sqm123.3123.3320.0FalseNoneNoneFalseNoneFalse39456.00
223278465297Nonevol 2,19.19,P-189Dismantling steel work manually/ by mechanical means in built up sections without dismembering and stacking to the appropriate disposal area as per direction of Engineer-in-charge. ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Kg3.393.391030.0FalseNoneNoneFalseNoneFalse3491.70
223278565297Nonevol 2,12.75.1,P-107Providing and fixing bright finished brass butt hinges with necessary screws etc complete 125x85x5.5mm heavy type ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Nos311.08311.0818.0FalseNoneNoneFalseNoneFalse5599.440
223278665297Nonevol 2,12.80.1,P-108Providing and fixing door latch with necessary screws etc complete.bright finished brass latch ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Nos322.39322.3912.0FalseNoneNoneFalseNoneFalse3868.680
223278765297Nonevol 2,12.79.1,P-108Providing and fixing bright finished brass handles with screws etc. complete Brass handles 125mm with plate 175x32 ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Nos281.67281.6712.0FalseNoneNoneFalseNoneFalse3380.040
17056600710000NoneNoneBuildingsCONSTRUCTION OF BOYS TOILET AT GROUNDFLOOR652957.42
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
223278865298Nonevol 1,1.4.1,P-5Earth work excavation by manual means for drains,canals and similar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Cum271.04271.0424.0FalseNoneNoneFalseNoneFalse6504.960
223278965298Nonevol 1,2.1.2,P-15Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork.Mix 1:4:8( M5) Using 40 mm and down size graded crushed coarse aggregates ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Cum6343.686343.681.5FalseNoneNoneFalseNoneFalse9515.520
223279065298Nonevol 2,5.4,P-9Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Cum7155.687155.6810.12FalseNoneNoneFalseNoneFalse72415.48160
223279165298Nonevol 1,2.5.2,P-16Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Cum12262.6612262.664.75FalseNoneNoneFalseNoneFalse58247.6350
223279265298Nonevol 2,6.8,P-14Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Cum8925.288925.2816.36FalseNoneNoneFalseNoneFalse146017.58080
223279365298Nonevol 2,8.2.2,P-41Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Sqm312.48312.4896.54FalseNoneNoneFalseNoneFalse30166.81920
223279465298Nonevol 2,8.8,P-42Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Sqm415.52415.5254.08FalseNoneNoneFalseNoneFalse22471.32160
223279565298Nonevol 2,9.21.2,P-62Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).600 *600 ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Sqm1386.561386.5691.22FalseNoneNoneFalseNoneFalse126482.00320
223279665298Nonevol 2,8.51,P-50Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Sqm112.0112.033.8FalseNoneNoneFalseNoneFalse3785.60
223279765298Nonevol 2,8.54.2,P-50Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Sqm123.2123.233.8FalseNoneNoneFalseNoneFalse4164.160
223279865298Nonevol 2,8.30,P-46Finishing walls with acrylic smooth exterior paints of required shape :new work(two coat applied at 1.67ltr/10sqm over and including priming coat of exterior primer applied at 2.2kg/10sqm)with paint of approved quality ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Sqm194.88194.8854.08FalseNoneNoneFalseNoneFalse10539.11040
223279965298Nonevol 2,12.54,P-104Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Sqm356.16356.163.78FalseNoneNoneFalseNoneFalse1346.28480
223280065298Nonevol 2,12.55.1,P-104Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3nos of 75mm Aluminium hinges.with both side prelam ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Sqm2649.922649.923.78FalseNoneNoneFalseNoneFalse10016.69760
223280165298Nonevol 2,12.85,P-109Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x1000mm. ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Sqm6405.286405.281.35FalseNoneNoneFalseNoneFalse8647.1280
223280265298Nonevol 1,2.11(a),P-18Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. FOR BUILDINGS ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Kg100.2100.2475.0FalseNoneNoneFalseNoneFalse47595.00
223280365298Nonevol 2,14.1.1,P-131Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 14.1.1 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.No5470.085470.082.0FalseNoneNoneFalseNoneFalse10940.160
223280465298Nonevol 2,14.4.4,P-132Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :Range of four urinal basins with 10 litre white P.V.C. automatic flushing cistern ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.No14638.414638.41.0FalseNoneNoneFalseNoneFalse14638.40
223280565298Nonevol 2,14.7.2,P-124Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar taps ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.No2868.322868.322.0FalseNoneNoneFalseNoneFalse5736.640
223280665298Nonevol 2,9.24,P-63Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Cum3194.243194.240.22FalseNoneNoneFalseNoneFalse702.73280
223280765298Nonevol 2,14.2.1,P-131Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Nos.5418.565418.561.0FalseNoneNoneFalseNoneFalse5418.560
223280865298Nonevol 2,11.16.2,P-82Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Kg159.04159.04274.0FalseNoneNoneFalseNoneFalse43576.960
223280965298Nonevol 2,7.38,P-26Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Sqm636.16636.1619.95FalseNoneNoneFalseNoneFalse12691.3920
223281065298Nonevol 2,12.80.2,P-108Providing and fixing door latch with necessary screws etc complete.oxidised mild steel door latch ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Nos88.4888.486.0FalseNoneNoneFalseNoneFalse530.880
223281165298Nonevol 2,itemno:710,P-A(33)Rectangular shape 1500x450mm mirror with plastic moulded frame ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Nos806.4806.41.0FalseNoneNoneFalseNoneFalse806.40
17056600710000NoneNoneBuildingsCONSTRUCTION OF GIRLS TOILET899666.22
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
223281265299Nonevol 1,2.5.2,P-16Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Cum7740.87740.81.24FalseNoneNoneFalseNoneFalse9598.5920
223281365299Nonevol 2,6.8,P-14Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Cum9014.539014.5337.88FalseNoneNoneFalseNoneFalse341470.39640
223281465299Nonevol 2,8.2.2,P-41Providing 15 mm cement plaster with cement mortar 1:6 (1 cement:6 fine sand) including rounding off corners wherever required smoothrendering, providing and removing caffolding, including cost ofmaterials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Sqm315.6315.6163.44FalseNoneNoneFalseNoneFalse51581.6640
223281565299Nonevol 2,8.8,P-42Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Sqm419.68419.6880.28FalseNoneNoneFalseNoneFalse33691.91040
223281665299Nonevol 2,9.21.2,P-62Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).600 *600 ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Sqm1400.431400.43151.92FalseNoneNoneFalseNoneFalse212753.32560
223281765299Nonevol 2,8.51,P-50Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Sqm113.12113.1256.4FalseNoneNoneFalseNoneFalse6379.9680
223281865299Nonevol 2,8.54.2,P-50Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Sqm124.43124.4356.4FalseNoneNoneFalseNoneFalse7017.8520
223281965299Nonevol 2,8.30,P-45Finishing walls with acrylic smooth exterior paints of required shape :new work(two coat applied at 1.67ltr/10sqm over and including priming coat of exterior primer applied at 2.2kg/10sqm)with paint of approved quality ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Sqm196.83196.8380.28FalseNoneNoneFalseNoneFalse15801.51240
223282065299Nonevol 2,12.54,P-104Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Sqm359.72359.7210.08FalseNoneNoneFalseNoneFalse3625.97760
223282165299Nonevol 2,12.55.1,P-106Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.with both side prelam ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Sqm2676.422676.4210.08FalseNoneNoneFalseNoneFalse26978.31360
223282265299Nonevol 2,12.85,P-109Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size -1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Sqm6469.336469.331.44FalseNoneNoneFalseNoneFalse9315.83520
223282365299Nonevol 2,14.1.1,P-131Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 14.1.1 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.No5524.785524.785.0FalseNoneNoneFalseNoneFalse27623.90
223282465299Nonevol 2,14.7.1,P-124Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.No2897.02897.04.0FalseNoneNoneFalseNoneFalse11588.00
223282565299Nonevol 1,2.11(a),P-18Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. FOR BUILDINGS ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Kg101.2101.218.58FalseNoneNoneFalseNoneFalse1880.2960
223282665299Nonevol 2,7.38,P-26Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Sqm642.52642.5260.0FalseNoneNoneFalseNoneFalse38551.20
223282765299Nonevol 2,11.16.2,P-82Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Kg166.29166.29500.0FalseNoneNoneFalseNoneFalse83145.00
223282865299Nonevol 2,14.2.1,P-131Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Nos5472.755472.753.0FalseNoneNoneFalseNoneFalse16418.250
223282965299Nonevol 2,12.80.2,P-108Providing and fixing door latch with necessary screws etc complete.oxidised mild steel door latch ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Nos89.3689.3616.0FalseNoneNoneFalseNoneFalse1429.760
223283065299Nonevol 2,itemno:710,P-A(33)Rectangular shape 1500x450mm mirror with plastic moulded frame ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.No814.46814.461.0FalseNoneNoneFalseNoneFalse814.460
17056600710000NoneNoneBuildingsCONSTRUCTION OF SEPTIC TANK AND SOAK PIT353136.64
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
223283165300Nonevol 1,1.4.1,P-5Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Cum271.04271.04104.4FalseNoneNoneFalseNoneFalse28296.5760
223283265300Nonevol 1,2.1.2,P-15Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Cum6343.686343.683.15FalseNoneNoneFalseNoneFalse19982.5920
223283365300Nonevol 1,2.5.2,P-16Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Cum7664.167664.1618.93FalseNoneNoneFalseNoneFalse145082.54880
223283465300Nonevol 2,8.2.2,P-41Providing 15 mm cement plaster with cement mortar 1:6 (1 cement:6 fine sand) including rounding off corners wherever required smoothrendering, providing and removing caffolding, including cost ofmaterials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Sqm312.48312.4855.0FalseNoneNoneFalseNoneFalse17186.40
223283565300Nonevol 1,2.11(a),P-18Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. FOR BUILDINGS ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Cum100.2100.21247.36FalseNoneNoneFalseNoneFalse124985.4720
223283665300Nonevol 2,17.1,P-175Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Cum1122.241122.244.65FalseNoneNoneFalseNoneFalse5218.4160
223283765300Nonevol 2,17.2,P-175Supplying, filling, spreading &leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Cum1328.321328.324.65FalseNoneNoneFalseNoneFalse6176.6880
223283865300Nonevol 2,17.3,P-175Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Cum1335.041335.044.65FalseNoneNoneFalseNoneFalse6207.9360
17056600710000NoneNoneBuildingsWATER SUPPLY AND UGD266310.56
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
223283965301Nonevol 2,13.33.5,P-123 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. 40 mm nominal dia Pipes ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.m534.24534.24110.0FalseNoneNoneFalseNoneFalse58766.40
223284065301Nonevol 2,13.31.3,P-122Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - 25 mm nominal dia Pipes ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.m356.16356.16100.0FalseNoneNoneFalseNoneFalse35616.00
223284165301Nonevol 5,P440B,P-164Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments 2 HP, Size 50x40 Head 22M, Discharge 186 LPM ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.No19566.419566.41.0FalseNoneNoneFalseNoneFalse19566.40
223284265301Nonevol 2,13.23.2,P-120Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball.20 mm nominal bore, 120 mm long, weighing not less than 198 g ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.No276.64276.6435.0FalseNoneNoneFalseNoneFalse9682.40
223284365301Nonevol 2,13.64.3,P-128Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. For 150mm nominal dia pipes ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.m860.16860.1625.0FalseNoneNoneFalseNoneFalse21504.00
223284465301Nonevol 5,N180C,P-147Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark.For 25 mm dia GM (Copper alloy) Gate valves ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.No1309.281309.286.0FalseNoneNoneFalseNoneFalse7855.680
223284565301Nonevol 2,13.34A,P-123Providing and fixing rectangular HDPE water storage loft tank with cover,conforming to IS:12701,colour of opaque white or as approved by Engineer-in-charge.The rates include necessary holes for inlet,outlet and over flow pipes.The base support i/c fittings and fixtures for tank shall be paid seperately. ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Ltr10.2810.284000.0FalseNoneNoneFalseNoneFalse41120.00
223284665301Nonevol 2,13.33.7,P-123Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. 65 mm nominal dia Pipes ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.m1568.01568.040.0FalseNoneNoneFalseNoneFalse62720.00
223284765301Nonevol 5,N020A,P-142Providing, Laying and Fixing GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For Heavy Duty GI pipe: Heavy Duty GI pipe of 15mm dia ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.m201.6201.624.0FalseNoneNoneFalseNoneFalse4838.40
223284865301Nonevol 2,13.5.1,P-117Providing and fixing ball valve (brass) of approved quality, High or low pressure with plastic floats complete 15mm nominal bore ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Nos331.52331.5214.0FalseNoneNoneFalseNoneFalse4641.280
17056600710000NoneNoneBuildingsELECTRICAL WORK FOR TWO LABORATORIES , TWO CLASSROOMS AND TWO TOILETS AT MARIKAMBA GOVT PU COLLEGE, SIRSI1076792.41
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
223284965302Nonevol-6, Page No.2, I.No.1.2.1Supplying heavy gauge PVC conduit pipe . mm dia.mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary - 19/20 mm dia 2 mm thick ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.m66.066.0975.0FalseNoneNoneFalseNoneFalse64350.00
223285065302Nonevol 6,page 2, 1.2.2Supplying heavy gauge PVC conduit pipe . mm dia.mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary - 25 mm dia 2 mm thick (PWD Electrical SR 2023-24, vol-6, Page No.2, I.No.1.2.2) ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.m78.078.0375.0FalseNoneNoneFalseNoneFalse29250.00
223285165302Nonevol-6, Page No.2, I.No.1.2.3Supplying heavy gauge PVC conduit pipe . mm dia.mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary - 32 mm dia 2.5 mm thick (PWD Electrical SR 2023-24, vol-6, Page No.2, I.No.1.2.3) ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.m103.0103.0150.0FalseNoneNoneFalseNoneFalse15450.00
223285265302Nonevol-6, Page No.2, I.No.1.3.1Supplying heavy gauge PVC Conduit Pipe . dia . mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary - 19/20 mm dia 2 mm thick (PWD Electrical SR 2023-24, vol-6, Page No.2, I.No.1.3.1) ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.m68.068.0245.0FalseNoneNoneFalseNoneFalse16660.00
223285365302Nonevol-6, Page No.2, I.No.1.3.2Supplying heavy gauge PVC Conduit Pipe . dia . mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary - 25 mm dia 2 mm thick (PWD Electrical SR 2023-24, vol-6, Page No.2, I.No.1.3.2) ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.m79.079.0125.0FalseNoneNoneFalseNoneFalse9875.00
223285465302Nonevol-6, Page No.2, I.No.1.3.3Supplying heavy gauge PVC Conduit Pipe . dia . mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary - 32 mm dia 2.5 mm thick (PWD Electrical SR 2023-24, vol-6, Page No.2, I.No.1.3.3) ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.m99.099.050.0FalseNoneNoneFalseNoneFalse4950.00
223285565302Nonevol-6, Page No.3, I.No.1.7.1Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete - upto 50 mm conduit in brick wall (PWD Electrical SR 2023-24, vol-6, Page No.3, I.No.1.7.1) ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.m29.029.0400.0FalseNoneNoneFalseNoneFalse11600.00
223285665302Nonevol-6, Page No.3, I.No.1.9.1Supplying PVC/GI flexible conduit pipe . mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely - 20 mm (PWD Electrical SR 2023-24, vol-6, Page No.3, I.No.1.9.1) ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.m19.019.050.0FalseNoneNoneFalseNoneFalse950.00
223285765302Nonevol-6, Page No.3, I.No.1.9.2Supplying PVC/GI flexible conduit pipe . mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely - 25 mm (PWD Electrical SR 2023-24, vol-6, Page No.3, I.No.1.9.2) ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.m22.022.050.0FalseNoneNoneFalseNoneFalse1100.00
223285865302Nonevol-6, Page No.5, I.No.2.2.1Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet - Short point upto 3m from tapping point to out let via switch (PWD Electrical SR 2023-24, vol-6, Page No.5, I.No.2.2.1) ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Point269.0269.030.0FalseNoneNoneFalseNoneFalse8070.00
223285965302Nonevol-6, Page No.5, I.No.2.2.2Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet - Medium point above 3m upto 6m from tapping point to out let via switch (PWD Electrical SR 2023-24, vol-6, Page No.5, I.No.2.2.2) ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Point379.0379.060.0FalseNoneNoneFalseNoneFalse22740.00
223286065302Nonevol-6, Page No.5, I.No.2.2.2Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet - Long point above 6m upto 10m from tapping point to out let via switch (PWD Electrical SR 2023-24, vol-6, Page No.5, I.No.2.2.2) ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Point555.0555.032.0FalseNoneNoneFalseNoneFalse17760.00
223286165302Nonevol-6, Page No.5, I.No.2.2.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments - 1.5 mm2 (PWD Electrical SR 2023-24, vol-6, Page No.5, I.No.2.2.2) ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.m26.026.01675.0FalseNoneNoneFalseNoneFalse43550.00
223286265302Nonevol-6, Page No.3, I.No.2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments - 2.5 mm2 (PWD Electrical SR 2023-24, vol-6, Page No.3, I.No.2.3.3) ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.m42.042.03350.0FalseNoneNoneFalseNoneFalse140700.00
223286365302Nonevol-6, Page No.5, I.No.2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments - 4 mm2 (PWD Electrical SR 2023-24, vol-6, Page No.5, I.No.2.3.4) ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.m63.063.01200.0FalseNoneNoneFalseNoneFalse75600.00
223286465302Nonevol-6, Page No.5, I.No.2.3.5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments - 6 mm2 (PWD Electrical SR 2023-24, vol-6, Page No.5, I.No.2.3.5) ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.m92.092.0250.0FalseNoneNoneFalseNoneFalse23000.00
223286565302Nonevol-6,Page No.6, I.No.2.3.5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments - 10 mm2 (PWD Electrical SR 2023-24, vol-6, Page No.6, I.No.2.3.5) ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.m167.0167.0100.0FalseNoneNoneFalseNoneFalse16700.00
223286665302Nonevol-6, Page No.8, I.No.3.2Supplying and mounting 2 Nos. of 2Way 6 A flush type switches either surface/flush mounted on existing gang box or in 4mm thick plastic sheet and mounted on a flush mounted wooden box and wiring as per IS 1293 (PWD Electrical SR 2023-24, vol-6, Page No.8, I.No.3.2) ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Each170.0170.04.0FalseNoneNoneFalseNoneFalse680.00
223286765302Nonevol-6, Page No.10, I.No.3.14.6Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board - 6A Lamp Holder (PWD Electrical SR 2023-24, vol-6, Page No.10, I.No.3.14.6) ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.No71.071.085.0FalseNoneNoneFalseNoneFalse6035.00
223286865302Nonevol-6, Page No.8, I.No.3.4.1Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall - 1-2 Way ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Each138.0138.020.0FalseNoneNoneFalseNoneFalse2760.00
223286965302Nonevol-6, Page No.8, I.No.3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall - 6 Way ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Each220.0220.020.0FalseNoneNoneFalseNoneFalse4400.00
223287065302Nonevol-6, Page No.8, I.No.3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall - 8 Way ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Each261.0261.015.0FalseNoneNoneFalseNoneFalse3915.00
223287165302Nonevol-6, Page No.8, I.No.3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall - 10-12 Way ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Each319.0319.040.0FalseNoneNoneFalseNoneFalse12760.00
223287265302Nonevol-6, Page No.8, I.No.3.4.7Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall - 16/18 Way ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Each363.0363.02.0FalseNoneNoneFalseNoneFalse726.00
223287365302Nonevol-6, Page No.8, I.No.3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box - 1 to 2 Module ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Each137.0137.020.0FalseNoneNoneFalseNoneFalse2740.00
223287465302Noneevol-6, Page No.8, I.No.3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box - 6 Module ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Each234.0234.020.0FalseNoneNoneFalseNoneFalse4680.00
223287565302Nonevol-6, Page No.8, I.No.3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box - 8 Module ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Each284.0284.015.0FalseNoneNoneFalseNoneFalse4260.00
223287665302Nonevol-6, Page No.8, I.No.3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box - 10-12 Module ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Each344.0344.040.0FalseNoneNoneFalseNoneFalse13760.00
223287765302Nonevol-6, Page No.8, I.No.3.5.7Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box - 16-18 Module ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Each397.0397.02.0FalseNoneNoneFalseNoneFalse794.00
223287865302Nonevol-6, Page No.9, I.No.3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 - 6A One Way Switch ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Each102.0102.0207.0FalseNoneNoneFalseNoneFalse21114.00
223287965302Nonevol-6, Page No.9, I.No.3.6.2Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 - 6A Two Way Switch ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Each166.0166.04.0FalseNoneNoneFalseNoneFalse664.00
223288065302Nonevol-6, Page No.9, I.No.3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 - 6A Three Way socket ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Each171.0171.085.0FalseNoneNoneFalseNoneFalse14535.00
223288165302Nonevol-6, Page No.9, I.No.3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 - Stepped Fan Regulator Two Module ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Each357.0357.032.0FalseNoneNoneFalseNoneFalse11424.00
223288265302Nonevol-6, Page No.9, I.No.3.6.7Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 -16A One Way Switch ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Each180.0180.020.0FalseNoneNoneFalseNoneFalse3600.00
223288365302Nonevol-6, Page No.9, I.No.3.6.8Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 -6A Bell Push ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Each177.0177.02.0FalseNoneNoneFalseNoneFalse354.00
223288465302Nonevol-6, Page No.9, I.No.3.6.11Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 -6/16A Universal Socket ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Each156.0156.020.0FalseNoneNoneFalseNoneFalse3120.00
223288565302Nonevol-6, Page No.9, I.No.3.8Supplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc, and fixing on existing wooden or metal box using N.F. screws. ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Sq CM0.410.4110000.0FalseNoneNoneFalseNoneFalse4100.00
223288665302Nonevol-6, Page No.9, I.No.3.10.1Extra for supplying 4 mm thick white plastic plate and covering for junction boxes of size . mm conduit using necessary machine screws - 60 mm ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.No8.08.050.0FalseNoneNoneFalseNoneFalse400.00
223288765302Nonevol-6, Page No.9, I.No.3.10.2Extra for supplying 4 mm thick white plastic plate and covering for junction boxes of size . mm conduit using necessary machine screws - 80/90 mm ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.No15.015.060.0FalseNoneNoneFalseNoneFalse900.00
223288865302Nonevol-6, Page No.17, I.No.5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 - 6-32 A SP ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Each415.0415.025.0FalseNoneNoneFalseNoneFalse10375.00
223288965302Nonevol-6, Page No.17, I.No.5.18.4Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 - 6-32 A DP ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Each739.0739.05.0FalseNoneNoneFalseNoneFalse3695.00
223289065302Nonevol-6, Page No.17, I.No.5.18.7Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 - 6-32 Amps TPN ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Each1717.01717.03.0FalseNoneNoneFalseNoneFalse5151.00
223289165302Nonevol-6, Page No.17, I.No.5.18.8Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 - 40 Amps TPN ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Each3044.03044.02.0FalseNoneNoneFalseNoneFalse6088.00
223289265302Nonevol-6, Page No.18, I.No.5.19.9Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure - III - Double Door - 12 Way SP & N ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Each2329.02329.03.0FalseNoneNoneFalseNoneFalse6987.00
223289365302Nonevol-6, Page No.21, I.No.5.45.2Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB (Without MCB). The entire plug and socket shall be mounted in a thermoplastic / powder coated metal box & wired Completely - SP & N - 20 Amps ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Each971.0971.06.0FalseNoneNoneFalseNoneFalse5826.00
223289465302Nonevol-6, Page No.21, I.No.5.45.4Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB (Without MCB). The entire plug and socket shall be mounted in a thermoplastic / powder coated metal box & wired Completely - TP & N - 30 Amps ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Each1700.01700.06.0FalseNoneNoneFalseNoneFalse10200.00
223289565302Nonevol-6, Page No.48, I.No.12.2.1Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote - Ding Dong Bell ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Each246.0246.02.0FalseNoneNoneFalseNoneFalse492.00
223289665302Nonevol-6, ESCOM SR, Page No.23, I.No.51.04Rod type of earthing using 40 mm Dia, 3 Mtr long MS rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal & connected to equipment ground terminal using PVC Al wire as specified ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.No2172.02172.02.0FalseNoneNoneFalseNoneFalse4344.00
223289765302Nonevol-6, ESCOM SR, Page No.30, I.No.6.1Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Each1492.01492.05.0FalseNoneNoneFalseNoneFalse7460.00
223289865302Nonevol-6, ESCOM SR, Page No.30, I.No.6.2.2Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system - 56" Sweep (1400 mm) Regular model ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Each3031.03031.032.0FalseNoneNoneFalseNoneFalse96992.00
223289965302Nonevol-6, ESCOM SR, Page No.43, I.No.11.3.2Supplying of .feet -PVC Batten with integrated LED tube . W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI more than 80. Power Input: 220-240V@ 50/60Hz & Power factor more than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition - LED light fitting 1 x 4' - 20/22 W ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Each690.0690.079.0FalseNoneNoneFalseNoneFalse54510.00
223290065302Nonevol-6, ESCOM SR, Page No.46, I.No.11.8.2Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor more than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency more than 1301m/w, nominal CRI more than 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.No4024.04024.06.0FalseNoneNoneFalseNoneFalse24144.00
223290165302Nonevol-6, ESCOM SR, Page No.47, I.No.11.11.5Supplying & fixing of retrofit type - LED bulb . W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy more than 80 lumen per W, life more than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition - 12W, 6500K ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Each269.0269.010.0FalseNoneNoneFalseNoneFalse2690.00
223290265302Nonevol-6, ESCOM SR, Page No.56, I.No.13.1.1Supplying and Fixing of.mm dia class A GI pipe bracket upto 2 ms long bent at suitable angle and fixing to this bracket 1x40/2x40 W fluorescent tube street light fitting of all capacities to GI or GI or rail or RCC pole / wall using suitable clA, bolts, and nuts and wiring using suitable capacity wires - Using 25 mm dia G.I.Pipe ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Each978.0978.06.0FalseNoneNoneFalseNoneFalse5868.00
223290365302Nonevol-6, ESCOM SR, Page No.56, I.No.13.5Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clA, bolts, nuts and wiring using suitable capacity wires. ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Each162.0162.06.0FalseNoneNoneFalseNoneFalse972.00
223290465302Nonevol-6, ESCOM SR, Page No.56, I.No.13.7.1Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA - On wall/ ceiling / Rafter / Girders ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Each122.0122.079.0FalseNoneNoneFalseNoneFalse9638.00
223290565302Nonevol-6, ESCOM SR, Page No.57, I.No.13.10Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Each171.0171.032.0FalseNoneNoneFalseNoneFalse5472.00
223290665302Nonevol-6, ESCOM SR, Page No.57, I.No.13.12Extra length of GI pipe of class B 19mm dia for down rod. ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.m197.0197.032.0FalseNoneNoneFalseNoneFalse6304.00
223290765302Nonevol-6, ESCOM SR, Page No.57, I.No.13.14Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire. ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Each492.0492.05.0FalseNoneNoneFalseNoneFalse2460.00
223290865302Nonevol-6, elect SR, Page No.15, I.No.5.12.2Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM Enclosure Sheet Metal Execution) - 100 Amps ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Each8534.08534.01.0FalseNoneNoneFalseNoneFalse8534.00
223290965302Nonevol-6, ESCOM SR, Page No.17, I.No.5.15.9Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism - FOUR POLE - 100 Amps 25 KVA ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Each8487.08487.01.0FalseNoneNoneFalseNoneFalse8487.00
223291065302Nonevol-6, ESCOM SR, Page No.17, I.No.15.16Supplying and fixing of Shunt trip suitable for MCCB.CBCT ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Each1703.01703.01.0FalseNoneNoneFalseNoneFalse1703.00
223291165302Nonevol-6, ESCOM SR, Page No.18, I.No.5.21Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board. ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Each9255.09255.01.0FalseNoneNoneFalseNoneFalse9255.00
223291265302Nonevol-6, ESCOM SR, Page No.19, I.No.5.27Supplying, fixing and wiring rotary selector switch suitable for Ammeter ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Each200.0200.01.0FalseNoneNoneFalseNoneFalse200.00
223291365302Nonevol-6, ESCOM SR, Page No.19, I.No.5.28Supplying, fixing and wiring rotary selector switch suitable for Voltmeter ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Each160.0160.02.0FalseNoneNoneFalseNoneFalse320.00
223291465302Nonevol-6, ESCOM SR, Page No.19, I.No.5.29Supplying, fixing and wiring 3 Phase Digital Ammeter / Voltmeter ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Each1425.01425.01.0FalseNoneNoneFalseNoneFalse1425.00
223291565302Nonevol-6, ESCOM SR, Page No.19, I.No.5.33Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, kVA, kWH, kVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Each9315.09315.01.0FalseNoneNoneFalseNoneFalse9315.00
223291665302Nonevol-6, ESCOM SR, Page No.19, I.No.5.34Supplying, fixing and wiring 50/5 to 400/5A 5VA burden Current Transformer Class 0.5 accuracy with Tape Wound. ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Each562.0562.01.0FalseNoneNoneFalseNoneFalse562.00
223291765302Nonevol-6, ESCOM SR, Page No.19, I.No.5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C. ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Each515.0515.03.0FalseNoneNoneFalseNoneFalse1545.00
223291865302Nonevol-6, ESCOM SR, Page No.19, I.No.5.40.1Supplying . A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete - 100 A 4 x 30 x 6 mm Aluminium Strips ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.m2465.02465.00.75FalseNoneNoneFalseNoneFalse1848.750
223291965302Nonevol-6, ESCOM SR, Page No.19, I.No.5.41.2Supplying and fixing angle iron frame work fabricated out of M.S. angle iron. and M.S. Flat.with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint - 50 x 50 x 6 mm ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.m395.0395.015.0FalseNoneNoneFalseNoneFalse5925.00
223292065302Nonevol-6, ESCOM SR, Page No.19, I.No.5.42.1Fabricating supplying and mounting MS box made out .SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete - 14 SWG ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Sq CM150000.0150000.00.5FalseNoneNoneFalseNoneFalse75000.00
223292165302NoneVol-6, ESCOM SR, Page No.13, I.No.32.081.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 - 25 Sqmm, 4 Core, (13 GI Strips - 4 x 0.8 mm) ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Km179844.0179844.00.1FalseNoneNoneFalseNoneFalse17984.40
223292265302NoneVol-6, ESCOM SR, Page No.13, I.No.32.051.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 - 16 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm) ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Km141842.0141842.00.03FalseNoneNoneFalseNoneFalse4255.260
223292365302NoneVol-6, ESCOM SR, Page No.13, I.No.21.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staf - 2.5 to 25 Sqmm ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Km20886.020886.00.13FalseNoneNoneFalseNoneFalse2715.180
223292465302NoneVol-1, common civil SR, Page No.10, I.No.1.19Earth work excavation for pipeline trenches in all kinds of by mechanical means above 600 mm trench width as per drawing and technicalspecifications, including setting out, construction of shoring,strutting,barricading, caution lights, bracing, using sight rails & bonding rods atevery 100 mm whevere necessary as directed, removal of slumps and other deleterious matter, dressing of sides and levelling the bottom oftrench to the extent required , utilising the available excavated earth locally for the work and all other appurtenances to complete in the following strata.Diamension:50.00x0.50mx 0.75m ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Cum342.0342.018.75FalseNoneNoneFalseNoneFalse6412.50
223292565302NoneVol-1, common civil SR, Page No.7, I.No.1.10Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications 50.00x0.50mx 0.75m ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Cum122.0122.018.75FalseNoneNoneFalseNoneFalse2287.50
223292665302NoneVol-6, ESCOM SR, Page No.30, I.No.66.04HDPE/PLB Pipe 50/42 mm ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Km85014.085014.00.13FalseNoneNoneFalseNoneFalse11051.820
223292765302Nonevol-6, ESCOM SR, Page No.26, I.No.59.02Heavy Duty Copper Terminal Long Barrel - 35 Sqmm Copper Terminal, Apprx Wt: 17 Gm ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.No40.040.08.0FalseNoneNoneFalseNoneFalse320.00
223292865302Nonevol-6, ESCOM SR, Page No.28, I.No.63.01Brass Cable Gland - 25 mm ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.No79.079.08.0FalseNoneNoneFalseNoneFalse632.00
223292965302NoneVol-6, ESCOM SR, Page No.54, I.No.12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.No3510.03510.04.0FalseNoneNoneFalseNoneFalse14040.00
223293065302NoneVol-6, ESCOM SR, Page No.54,I.No.12.58.2GI/Copper strips for grounding connections, using necessary fixing materials as required. 25 x 3 mm GI strip ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.No82.082.040.0FalseNoneNoneFalseNoneFalse3280.00
17056600710000NoneNoneBuildingsCONSTRUCTION OF CLASSROOM(GROUNDFLOOR) FOR MARIKAMBA GOVT PU COLLEGE AT SIRSI TALUK,UK DISTRICT1713237.69
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
223293165303Nonevol 1,1.14.1,P-8Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Cum114.24114.2497.34FalseNoneNoneFalseNoneFalse11120.12160
223293265303Nonevol 1,2.1.2,P-15Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Cum6343.686343.685.41FalseNoneNoneFalseNoneFalse34319.30880
223293365303Nonevol 1,2.5.2,P-16Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Cum7664.167664.1623.04FalseNoneNoneFalseNoneFalse176582.24640
223293465303Nonevol 1,1.9,P-7Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Cum297.92297.9296.38FalseNoneNoneFalseNoneFalse28713.52960
223293565303Nonevol 1,2.5.2,P-16Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Cum13029.0713029.075.95FalseNoneNoneFalseNoneFalse77522.96650
223293665303Nonevol 1,2.5.2,P-16Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Cum12262.6612262.669.54FalseNoneNoneFalseNoneFalse116985.77640
223293765303Nonevol 1,2.5.2,P-16Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Cum11496.2411496.248.83FalseNoneNoneFalseNoneFalse101511.79920
223293865303Nonevol 1,2.11(a),P-18Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. FOR BUILDINGS ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Kg100.2100.23776.74FalseNoneNoneFalseNoneFalse378429.3480
223293965303Nonevol 2,6.8,P-14Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of enginner inchargeof work ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Cum8925.288925.2825.21FalseNoneNoneFalseNoneFalse225006.30880
223294065303Nonevol 2,8.2.2,P-41Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Sqm312.48312.48111.24FalseNoneNoneFalseNoneFalse34760.27520
223294165303Nonevol 2,8.8,P-42Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Sqm415.52415.52132.16FalseNoneNoneFalseNoneFalse54915.12320
223294265303Nonevol 2,9.21.2,P-62Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).600 *600 ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Sqm1386.561386.5666.47FalseNoneNoneFalseNoneFalse92164.64320
223294365303Nonevol 2,8.51,P-50Providing and applying white cement based putty of average thickness 1 mm, of pproved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Sqm112.0112.0172.85FalseNoneNoneFalseNoneFalse19359.20
223294465303Nonevol 2,8.54.2,P-50Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Sqm123.2123.2172.85FalseNoneNoneFalseNoneFalse21295.120
223294565303Nonevol 2,8.30,P-46Finishing walls with Acrylic Smooth exterior paint of required shade New work Two coat applied 1.67L/10 m² over and including priming coat of exterior primer applied 2.20 kg/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of the engineer in charge ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Sqm194.88194.88132.16FalseNoneNoneFalseNoneFalse25755.34080
223294665303Nonevol 2,12.13.1,P-100Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled includingmaking plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Cum110672.8110672.80.14FalseNoneNoneFalseNoneFalse15494.1920
223294765303Nonevol 2,12.18,P-100Providing and fixing in position fully panelled Matti/Nandi wood shutters for doors with, stiles and rails of 35mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures ) ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Sqm7365.127365.125.04FalseNoneNoneFalseNoneFalse37120.20480
223294865303Nonevol 2,8.55.1,P-50Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hardand soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge. ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Sqm62.7262.7210.08FalseNoneNoneFalseNoneFalse632.21760
223294965303Nonevol 2,8.41,P-48Painting with synthetic enamel paint of approved brand andmanufacture of required colour to give an even shade :Two coats onnew work over an under coat of suitable shade with ordinary paintof approved brand and manufacture after thoroughly brooming thesurface to remove all dirt, dust, mortar drops and foreign matterincluding preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directionsof Engineer-in-charge. ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Sqm187.04187.0410.08FalseNoneNoneFalseNoneFalse1885.36320
223295065303Nonevol 2,12.84,P-108Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC (Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6 PHR with TPE (Thermo PlasticElastomer) and lead free, gaskets -grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame The outer frame having an overall size of 44mm width x 40mmheight with reinforcement of 1mm thickness and Sash with overall size of 27mm X 53mm with UPVC honeycomb structure inside in lieu of GIreinforcement. Coextruded Glazing bead for fixing of glass shall be of size 9.5mm x 21.5mm. Windows shall be provided with 5mm plain floatglass, standard hardware& single point locking system with Crescent Locks. Wall thickness of frame & sash shall be of 2 mm.Maximum possible size 1219mm x 1219mm. ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Sqm5625.765625.767.2FalseNoneNoneFalseNoneFalse40505.4720
223295165303Nonevol 2,12.85,P-109Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced withGalvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness.Louver clip in Aluminium (powder coated in white) will be used on theframe along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x1000mm The cost is inclusive of all fixtures and separate charges for ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Sqm6405.286405.281.8FalseNoneNoneFalseNoneFalse11529.5040
223295265303Nonevol 2,11.16.2,P-82Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Kg159.04159.041000.0FalseNoneNoneFalseNoneFalse159040.00
223295365303Nonevol 2,11.34B.2,P-86Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Kg204.96204.96151.2FalseNoneNoneFalseNoneFalse30989.9520
223295465303Nonevol 2,7.38,P-26Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Sqm636.16636.1621.0FalseNoneNoneFalseNoneFalse13359.360
223295565303Nonevol 2,12.75.1,P-107Providing and fixing bright finished brass butt hinges with necessary screws etc complete 125x85x5.5mm heavy type ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Nos308.0308.06.0FalseNoneNoneFalseNoneFalse1848.00
223295665303Nonevol 2,12.80.1,P-108Providing and fixing door latch with necessary screws etc complete.bright finished brass latch ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Nos319.2319.24.0FalseNoneNoneFalseNoneFalse1276.80
223295765303Nonevol 2,12.79.1,P-108Providing and fixing bright finished brass handles with screws etc. complete Brass handles 125mm with plate 175x32 ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Nos278.88278.884.0FalseNoneNoneFalseNoneFalse1115.520
17056600710000NoneNoneBuildingsCONSTRUCTION OF CLASSROOM(FIRST FLOOR) FOR MARIKAMBA GOVT PU COLLEGE AT SIRSI TALUK,UK DISTRICT1626324.25
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
223295865304Nonevol 1,2.5.2,P-16Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Cum13105.7113105.716.02FalseNoneNoneFalseNoneFalse78896.37420
223295965304Nonevol 1,2.5.2,P-16Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Cum12339.312339.36.15FalseNoneNoneFalseNoneFalse75886.6950
223296065304Nonevol 1,2.5.2,P-16Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Cum11572.8811572.888.83FalseNoneNoneFalseNoneFalse102188.53040
223296165304Nonevol 1,2.11(a),P-18Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. FOR BUILDINGS ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Kg101.2101.23454.17FalseNoneNoneFalseNoneFalse349562.0040
223296265304Nonevol 2,6.8,P-14Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of enginner inchargeof work ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Cum9014.539014.5332.75FalseNoneNoneFalseNoneFalse295225.85750
223296365304Nonevol 2,8.2.2,P-41Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Sqm315.6315.6111.24FalseNoneNoneFalseNoneFalse35107.3440
223296465304Nonevol 2,8.8,P-42Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Sqm419.68419.68132.16FalseNoneNoneFalseNoneFalse55464.90880
223296565304Nonevol 2,9.21.2,P-62Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).600 *600 ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Sqm1400.431400.4366.47FalseNoneNoneFalseNoneFalse93086.58210
223296665304Nonevol 2,8.51,P-50Providing and applying white cement based putty of average thickness 1 mm, of pproved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Sqm113.12113.12172.85FalseNoneNoneFalseNoneFalse19552.7920
223296765304Nonevol 2,8.54.2,P-50Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Sqm124.43124.43172.85FalseNoneNoneFalseNoneFalse21507.72550
223296865304Nonevol 2,8.30,P-46Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of the engineer in charge ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Sqm196.83196.83132.16FalseNoneNoneFalseNoneFalse26013.05280
223296965304Nonevol 2,12.13.1,P-100Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled includingmaking plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Cum111779.53111779.530.14FalseNoneNoneFalseNoneFalse15649.13420
223297065304Nonevol 2,12.18,P-100Providing and fixing in position fully panelled Matti/Nandi wood shutters for doors with, stiles and rails of 35mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures ) ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Sqm7438.777438.775.04FalseNoneNoneFalseNoneFalse37491.40080
223297165304Nonevol 2,8.55.1,P-50Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hardand soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge. ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Sqm63.3563.3510.08FalseNoneNoneFalseNoneFalse638.5680
223297265304Nonevol 2,8.41,P-48Painting with synthetic enamel paint of approved brand andmanufacture of required colour to give an even shade :Two coats onnew work over an under coat of suitable shade with ordinary paintof approved brand and manufacture after thoroughly brooming thesurface to remove all dirt, dust, mortar drops and foreign matterincluding preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directionsof Engineer-in-charge. ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Sqm188.91188.9110.08FalseNoneNoneFalseNoneFalse1904.21280
223297365304Nonevol 2,12.84,P-108Providing & fixing of 2-track x 2-panel sliding windows made out ofmulti chambered UPVC (Matching to RAL-9016) sections and withminimum TiO2(Titanium Dioxide) at 6 PHR with TPE (Thermo PlasticElastomer) and lead free, gaskets -grey color having isolated drainageand reinforced with Galvanized Iron profile through-out the window frame The outer frame having an overall size of 44mm width x 40mmheight with reinforcement of 1mm thickness and Sash with overall size of 27mm X 53mm with UPVC honeycomb structure inside in lieu of GIreinforcement. Coextruded Glazing bead for fixing of glass shall be of size 9.5mm x 21.5mm. Windows shall be provided with 5mm plain floatglass, standard hardware& single point locking system with Crescent Locks. Wall thickness of frame & sash shall be of 2 mm.Maximumpossible size 1219mm x 1219mm. ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Sqm5682.025682.027.2FalseNoneNoneFalseNoneFalse40910.5440
223297465304Nonevol 2,12.85,P-109Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced withGalvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness.Louver clip in Aluminium (powder coated in white) will be used on theframe along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x1000mm.(The cost is inclusive of all fixtures and separate charges for ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Sqm6469.336469.331.8FalseNoneNoneFalseNoneFalse11644.7940
223297565304Nonevol 2,11.16.2,P-82Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Kg160.63160.631758.0FalseNoneNoneFalseNoneFalse282387.540
223297665304Nonevol 2,11.34B.2,P-86Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Kg207.01207.01151.2FalseNoneNoneFalseNoneFalse31299.9120
223297765304Nonevol 2,7.38,P-26Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Sqm642.52642.5274.12FalseNoneNoneFalseNoneFalse47623.58240
223297865304Nonevol 2,12.75.1,P-107Providing and fixing bright finished brass butt hinges with necessary screws etc complete 125x85x5.5mm heavy type ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Seedl311.08311.086.0FalseNoneNoneFalseNoneFalse1866.480
223297965304Nonevol 2,12.80.1,P-108Providing and fixing door latch with necessary screws etc complete.bright finished brass latch ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Nos322.39322.394.0FalseNoneNoneFalseNoneFalse1289.560
223298065304Nonevol 2,12.79.1,P-108Providing and fixing bright finished brass handles with screws etc. complete Brass handles 125mm with plate 175x32 ---- including cost of all materials, with all lead and lift, transporting to site, loading and unloading, labour charges, HOM, etc complete as per specifications and as per directions of Engineer-in-charge of Work.Nos281.67281.674.0FalseNoneNoneFalseNoneFalse1126.680
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17056600720002NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17056600720001NoneNoneELIGIBILITYBidder shall pay Contract Management Module processing fees of 0.025% of the contact value (Min Rs.500/- & Max Rs.7500/-) soon after contract has been issued to bidder.None
17056600720001NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by any State Government / Government of India /Union Territory.None
17056603270000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of KPPP on or before the last date and time of bid submission.None
17056603460000NoneNoneELIGIBILITYThe bidder is required to ensure browser compatibility of the computer well in advance to the last date and time for receipt of tenders. The departments shall not be responsible for non-accessibility of KPPP portal due to internet connectivity issues and technical glitches at bidders end.None
17056603540000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17056603630000NoneNoneELIGIBILITYAs per Karnataka State Government order LD/300/LET/2006 Bangalore dated 01-01-2007 and Government letter No PW/134/BMS/2007 dated 27.07.2007, a sum amounting to 1% of the bill amount will be deducted towards construction labour welfare fund.None
17056603780000NoneNoneELIGIBILITYThe Item rates quoted shall include cost of Royalty charges on construction materials and other taxes (except GST) as per the rates provided in prevailing Government Orders at the time of execution and including cost and conveyance of all materials, curing, loading and Unloading with all lifts, labour, Hire charges of machinery and equipment s etc, complete and all other incidental charges.None
17056603850000NoneNoneELIGIBILITYConstitutional or Legal Status of tenderer.None
17056603920000NoneNoneELIGIBILITYQualification & experience of key Technical & management personnel in permanent employment with the Tender & those that are proposed to be deployed on this work if awarded.None
17056604000000NoneNoneELIGIBILITYFinancial Year will be reckoned as the period between first day of April and Thirty First day of March of succeeding year (both days inclusive).None
17056604070000NoneNoneELIGIBILITYThe employer is not responsible for any delay in accessing KPPP Portal.None
17056604120000NoneNoneELIGIBILITYAll materials required for this work, shall be produced by the tenderer himself and should be got tested by the quality control authorities, at his own cost before using for the work.None
17056604180000NoneNoneELIGIBILITYConditional tenders will not accept.None
17056604250000NoneNoneELIGIBILITYThe employer reserves the rights to Reject one or all Tenders without assigning any reasons.None
17056604380000NoneNoneELIGIBILITYThe construction materials (minerals metal, sand and murrum) shall be bought from the authorized quarries along with the mineral dispatch permit or else 5 times the royalty will be deducted as penalty as per the Directions on the Director, Mines and Geology Department Bangalore proceedings dated 25.03.2013.None
17056604450000NoneNoneELIGIBILITYThe field laboratory shall preferably locate, adjacent to the site with the required amenity as per the clause. Failing which 1% of the amount of work done will be penalizedNone
17056604530000NoneNoneELIGIBILITYThe tenderers are requested to abide instructions and conditions contained in the Standard Bid Documents -KW-4 and further orders thereon.None
17056605200000NoneNoneELIGIBILITYEligible Tenderers will be qualified only if their available tender capacity is more than the total tender value. The available tender capacity will be calculated as under assessed available tender capacity is A X N X 1.5 - B where A is Maximum value of civil engineering works executed in any one year during the last five years taking into account the completed as well as works in progress. N is Number of years prescribed for completion of the works for which Tenders are invited. B is Existing commitments and ongoing works to be completed.None
17056605340000NoneNoneELIGIBILITYDefect labiality period (DLP) is 02 years from the date of completion.None
17056605410000NoneNoneELIGIBILITYThe Work Completion Period is 11 months (including Monsoon)None
17056605470000NoneNoneELIGIBILITYEligible Contractors can ApplyNone
17056605540000NoneNoneELIGIBILITYGST shall be paid to the tendered amount separately.None
17056605610000NoneNoneELIGIBILITYThe Increase in G.S.T shall not be paid in the extended period of Contract for which the contractor alone is responsible for delay as determined by the authority while granting the extension of time.None
17056605680000NoneNoneELIGIBILITYIf the rate quoted by the Successful Tenderer is less than the Amount put to tender, then the difference amount should be paid in the form of FDR / BG (Period 01 year) in favour of Executive Engineer, PWD Division Sirsi at the time of agreement.None
17056605750000NoneNoneELIGIBILITYTenderers shall obtain the Work Done Certificate in the prescribed format from the Competent Authourity not below the rank of Executive Engineer (District Level Officer) and Scan the original certificates and attach the scanned file to the tenders. The all original Certificate (Work done, BG, LOC, Financial Turnover) shall be produced before opening of Technical Bid for physical verification, otherwise bid will not be considered for evaluation.None
17056605860000NoneNoneELIGIBILITYEMD Rs. 2,00,000/- Part (1) Rs. 1,00,000/- by e-payment & Part(2) Rs. 1,00,000/- in the form of Bank Guarantee issued by Nationalized/Scheduled Bank in favopr of Executive Engineer, PWD Division, Sirsi. Contractor should upload the scanned Copy of Bank Guarantee and the Original Bank Guarantee should be handed over TO THE EXECUTIVE ENGINEER.None
17057540860001NoneNoneELIGIBILITYStar Rates are applicable as per Government Circular number PWD:159:CRM:2009 Bangalore Dtd:30-09-2010.None
17065224120000NoneNoneELIGIBILITYAny deviation /error/mistake found in units of items, they should be read as in the unified SR 2023-24 and the rates shall be quoted accordinglyNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNone3.2 b To qualify for award of this contract, each tenderer in his name should have in the last five years ( i.e. 2018-19 to 2022-23) (b) satisfactorily completed (at least 90% of the contract value) as prime contractor, at least one similar work (One Single Building Work) of value not less than Rs. 64.26 Lakhs (usually not less than 50% of estimated value of contract)Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- workdone
NoneNoneNoneNoneTotal value of works Executed and payments received during 2022-23Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Information is to be furnished in Format I
NoneNoneNoneNoneTotal value of works Executed and payments received in the last five years 2018-19, 2019-20, 2020-21, 2021-22 and 2022-23Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Information is to be furnished in Format I
NoneNoneNoneNoneWork Done Certificate obtained from the Competent AuthoritiesPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Information is to be furnished in Format VII
NoneNoneNoneNone3.3 b Each Tenderer shall furnish Liquid Assets and/or availability of credit facilities of not less than Rs. 35.05 Lakhs- (Credit Lines/ Letter of Credit/ Certificates from banks for meeting the fund requirement etc. in the prescribed format only. Any conditional Liquid Assets/availability of credit facility certificate will be Rejected.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Information is to be furnished in prescribed Format
NoneNoneNoneNone3.2 c To qualify for award of this contract, each Tenderer in its name should have in the last five years (i.e. 2018-19 to 2022-23). Each Tenderer shall Executed in any one financial year, the following minimum quantities of the work. Earthwork 180.59 m3, Concrete work (including PCC/RCC) 159.37 m3, Steel work 15979.31 Kg , Flooring work 691.64 m2, Masonry work 166.38m3, Wood Work 0.43m3, Plastering Work 1613.15m2.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Information is to be furnished in Format III
NoneNoneNoneNoneQualification and experience of the key Technical and Management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this work if awardedCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Bio data of the personnel
NoneNoneNoneNoneEach Tenderer should further demonstrate As per this note, each tenderer should demonstrate availability of few key equipment s/machinery for execution of the work. However as per Govt circular no GO-FD/AE 263/EXP-12/2022, Bangalore Dtd:11.05.2022, this clause for owning key equipments for works costing up to Rs. 3.00 crores is exempted. However it is obligatory for the contractor to use the following machinery for various activities involved in construction as per Morth specification. 1) Weigh Batch Self Loading Concrete Mixer, 2) M S Shuttering Materials, 3) Tippers, 4) Excavator like JCB/Hitachi, 5) Water Tankers, 6) Pin/Plate Concrete Vibrators, 7) Construction ElevatorCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Information is to be furnished in Format VIII
NoneNoneNoneNoneEMD Rs. 2,00,000/- Part (1) Rs.1,00,000/- by e-payment & Part(2) Rs. 1,00,000/- in the form of Bank Guarantee issued by Nationalized/Scheduled Bank in favour of Executive Engineer, PWD Division, Sirsi. Contractor should upload the scanned Copy of Bank Guarantee and the Original Bank Guarantee should be handed over TO THE EXECUTIVE ENGINEER.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- BG in prescribed format
NoneNoneNoneNone3.2 a To qualify for award of this contract, each tenderer in his name should have in the last five years (i.e. 2018-19 to 2022-23) achieved in at least two financial years a minimum financial turnover (in all classes of civil engineering construction works only) of Rs. 257.04 Lakhs.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Information is to be furnished in Format II
NoneNoneNoneNoneReports on the financial standing of the Bidder, such as profit and Loss statement and Auditors Report for the last five years.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Auditors Report
NoneNoneNoneNoneInformation on litigation in which the Tender is involvedOthersLitigation
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Information is to be furnished in Format X
NoneNoneNoneNoneConstructional or Legal Status of the TendererOthersConstructional or Legal Status of the Tenderer
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneName, Address, Telephone, Fax and email ID of the Tenderers bankers who may provide reference, if contacted by the EmployerOthersBankers Information
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Declaration by the bidder on letter head furnishing the place of Business
NoneNoneNoneNonePrincipal Place of BusinessOthersPlace of Business
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Declaration by the bidder on letter head furnishing the place of Business
NoneNoneNoneNoneInformation on the works which tender has submitted TenderOthersTender Works
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Information is to be furnished in Format VI
NoneNoneNoneNoneInformation of Works for which Tender Acceptance Letters are received/Tender ApprovedOthersTender Accepted
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Information is to be furnished in Format V
NoneNoneNoneNoneInformation on the Works which are yet to be CompletedOthersOngoing Works
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Information is to be furnished in Format IV
NoneNoneNoneNoneProposed methodology and Program of construction, backed with equipment, Planning and deployment, duly supported with Broad calculations and quality control procedures to be adopted, justifying their capability of execution and completion of the work as per technical specifications within the stipulated period of completion as per milestones.OthersPlanning
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Bar Chart / PERT and Report
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Company/Contractor Registration Certificate PWDTrueTechnical Bid
Turnover Certificate with Civil work Balance Sheets 2018-19 to 2022-23 with UDINTrueTechnical Bid
Work done Certificate with quantities 2018-19 to 2022-23TrueTechnical Bid
Bankers Certificate Line of CreditTrueTechnical Bid
Bidders Address & Mobile No.TrueTechnical Bid
Work Execution Programme Bar Chart of 11 MonthsTrueTechnical Bid
Existing commitments and Bid capacity DetailsTrueTechnical Bid
Single Similar nature of Work done CertificateTrueTechnical Bid
tenderWorkLocationList
tenderSubEstimateNamedistrictNametaluqNameloksabhaContNameassemblyContNamelocationDescriptionlatitudeDegreeslatitudeMinuteslatitudeSecondslongitudeDegreeslongitudeMinuteslongitudeSeconds
BuildingsUttara KannadaSirsiKanaraSIRSI (SC)Marikamba govt pu collge, near court,SirsiNoneNoneNoneNoneNoneNone
BuildingsUttara KannadaSirsiKanaraSIRSI (SC)Marikamba govt pu college , near court, sirsiNoneNoneNoneNoneNoneNone
BuildingsUttara KannadaSirsiKanaraSIRSI (SC)Marikamba govt pu college, near court , sirsiNoneNoneNoneNoneNoneNone
BuildingsUttara KannadaSirsiKanaraSIRSI (SC)Marikamba govt pu college, near court , sirsiNoneNoneNoneNoneNoneNone
BuildingsUttara KannadaSirsiKanaraSIRSI (SC)Marikamba govt pu college , near court , sirsiNoneNoneNoneNoneNoneNone
BuildingsUttara KannadaSirsiKanaraSIRSI (SC)Marikamba pu govt college, near court, sirsiNoneNoneNoneNoneNoneNone
BuildingsUttara KannadaSirsiKanaraSIRSI (SC)Marikamba Govt PU college,near court , SirsiNoneNoneNoneNoneNoneNone
BuildingsUttara KannadaSirsiKanaraSIRSI (SC)Marikamba Govt PU college, near court , SirsiNoneNoneNoneNoneNoneNone
tenderAddress
createdTs1706526964000
version0
createdDateNone
modifiedDateNone
blockNumberPWD Division Office, sirsi
streetNone
citySirsi
stateKARNATAKA
pin581401
tenderRecallDTONone