createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1706940040245
version11
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee7500.00
emd1500000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose12-02-2024 17:00:00
tenderQueryClose08-02-2024 16:00:00
technicalBidOpen13-02-2024 17:01:00
publishedDate05-02-2024 10:29:19
publishedByPostIDD_EE_DIV_UDP
publishedByUserKPE17153 - R NAGARAJ
bidValidityPeriod90
noOfCalls3
preBidMeetingDate06-02-2024 11:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnTrue
percentageRateTypeTextNone
contactPersonBhanuprakash
splitEmdRequiredYnTrue
emdBankGuarantee1400000.00
emdCash100000.00
bgValidityPeriod180
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08202532961
mobileNumber9900328119
tenderSupplierListNone
tenderSchedule
createdTs1706940040247
version28
createdDateNone
modifiedDateNone
tenderNumberIDD/2023-24/OW/WORK_INDENT25/CALL-3
titleEstablishment of New Fish Farm Near Alamtti Dam in Vijayapura District.
descriptionEstablishment of new Fish Farm
categoryWORKS
categoryTextWorks
ecv106202329.21
deptNameInfrastructure Development Ports And Inland Water Transport Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location5472
locationNameExecutive engineer Udupi
provisionalAmount130475000.0
groupOverheadTotal0.0
fileNumberIDD/2023-24/ALAMATTIWORK
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17069400400001NoneNoneOther WorksConstruction of Office Building5952272.69
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
241287872217Volume -1-Common SR- Chapter - I- Earth Work1.14.1In all kinds of soils Depth upto 3 mCum73.076.65875.88FalseNoneNoneFalseNoneFalse67136.2020
241288072217Volume-2-For Buildings Chapter-12-Wood & PVC Works12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Cum61603.064683.150.68FalseNoneNoneFalseNoneFalse43984.5420
241288272217Volume-2-For Buildings Chapter-12-Wood & PVC Works12.57.435 mm thick both side TeakSqm2333.02449.654.5FalseNoneNoneFalseNoneFalse11023.4250
241288472217Volume-2-For Buildings Chapter-12-Wood & PVC Works12.17Providing and fixing in position fully panelled Honne wood shutters for doors with , stiles and rails of 35mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures)Sqm4866.05109.322.5FalseNoneNoneFalseNoneFalse114959.250
241288672217Volume-2-For Buildings Chapter-12-Wood & PVC Works12.54Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge.Sqm475.0498.7517.1FalseNoneNoneFalseNoneFalse8528.6250
241288872217Volume-2-For Buildings Chapter-12-Wood & PVC Works12.55.2with one side prelamSqm2856.02998.84.73FalseNoneNoneFalseNoneFalse14184.3240
241289072217Volume-2-For Buildings Chapter-12-Wood & PVC Works12.86Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC (Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 50mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm X 57mm with Gi reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 1.8+-0.2 mm. Maximum possible size – 1519mm x 1519mm. (The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made)Sqm5842.06134.123.83FalseNoneNoneFalseNoneFalse146175.6030
241289372217Volume-2-For Buildings Chapter-15-Water Proofing15.1Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per Sqm to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per Sqm and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.Sqm745.0782.25260.52FalseNoneNoneFalseNoneFalse203791.770
241289572217Volume-2-For Buildings Chapter-8-Finishing8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.Sqm83.087.15585.88FalseNoneNoneFalseNoneFalse51059.4420
241289772217Volume-2-For Buildings Chapter-8-Finishing8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm95.099.75774.39FalseNoneNoneFalseNoneFalse77245.40250
241289972217Volume-2-For Buildings Chapter-8-Finishing8.28Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 Sqm) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm66.069.3201.84FalseNoneNoneFalseNoneFalse13987.5120
241290172217Volume-2-For Buildings Chapter-8-Finishing8.47Polishing on wood work with ready mixed wax polish of approved brand and manufacture : New work to give an even surface including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm107.0112.3512.67FalseNoneNoneFalseNoneFalse1423.47450
241290372217Volume-2-For Buildings Chapter-8-Finishing8.4Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm90.094.590.36FalseNoneNoneFalseNoneFalse8539.020
241290572217Volume-2-For Buildings Chapter-9-Flooring9.32Providing and laying heavy duty cobble stones 75mm thick interlock pavers, using cement and course sand for manufacture of blocks of approved size, shape and colour with a minimum compressive strength of 281 kg per Sqm over 50mm thick sand bed ( average thickness ) and compacting with plate vibrator having 3 tons compaction force thereby forcing part of sand underneath to come up in between joints, final compaction of paver surface joints into its final level, including cost of materials, labour and Usage charges of machinery complete as per specifications.Sqm1145.01202.2563.36FalseNoneNoneFalseNoneFalse76174.560
241290672217Volume-2-For Buildings Chapter-4-Anti-Termite Treatment4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/Sqm including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.Sqm95.099.75203.67FalseNoneNoneFalseNoneFalse20316.08250
241290872217Volume-2-For Buildings Chapter-17-Rain Water Harvesting17.1Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.Cum960.01008.0250.0FalseNoneNoneFalseNoneFalse252000.00
241291072217Volume-2-For Buildings Chapter-17-Rain Water Harvesting17.2Supplying, filling, spreading &leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.Cum372.0390.6250.0FalseNoneNoneFalseNoneFalse97650.00
241291272217Volume-2-For Buildings Chapter-14-Sanitary Installations14.3.1W.C. pan with ISI marked white solid plastic seat and lideach5005.05255.253.0FalseNoneNoneFalseNoneFalse15765.750
241291472217Volume-2-For Buildings Chapter-14-Sanitary Installations14.7.2White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tapeach2156.02263.82.0FalseNoneNoneFalseNoneFalse4527.60
241291672217Volume-2-For Buildings Chapter-14-Sanitary Installations14.7.10Stainless Steel AISI-304(18/8) Round basin 405x355 mm with single 15 mm C.P. brass pillar tapeach3112.03267.61.0FalseNoneNoneFalseNoneFalse3267.60
241291872217Volume-2-For Buildings Chapter-13-Water Suppy & Drainage Works13.2.220 mm nominal boreNos.345.0362.257.0FalseNoneNoneFalseNoneFalse2535.750
241292172217Volume-2-For Buildings Chapter-13-Water Suppy & Drainage Works13.4.232 mm nominal boreNos.577.0605.852.0FalseNoneNoneFalseNoneFalse1211.70
241292372217Volume-2-For Buildings Chapter-13-Water Suppy & Drainage Works13.4.125 mm nominal boreNos.528.0554.43.0FalseNoneNoneFalseNoneFalse1663.20
241292472217Volume-2-For Buildings Chapter-13-Water Suppy & Drainage Works13.6.2.1HorizontalNos.644.0676.21.0FalseNoneNoneFalseNoneFalse676.20
241292672217Volume-2-For Buildings Chapter-14-Sanitary Installations14.31Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.each971.01019.553.0FalseNoneNoneFalseNoneFalse3058.650
241292872217Volume-2-For Buildings Chapter-14-Sanitary Installations14.40.2600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g.each380.0399.03.0FalseNoneNoneFalseNoneFalse1197.00
241287972217NoneA130AProviding and Filling in foundation with granite / trap broken metal 100mm and down size with approved M-Sand including hand packing, ramming, watering including cost of all materials and labour with all lead and lift complete as per specifications. (Pg. No. 64 SOR Code A130A SR 2021-22 V- 5)Cum1672.651672.6561.91FalseNoneNoneFalseNoneFalse103553.76150
241288172217None2.1.2Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8 (M5) Using 40 mm nominal size graded crushed coarse aggregates. (Vol-1, Pg. No.15, Item No. 2.1.2, SR 2021-22)Cum5466.35466.342.38FalseNoneNoneFalseNoneFalse231661.7940
241288372217None2.2.2.1Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Item No.2.2.2.1 Vol-1 Pg No. 15 SR 2021-22)Additionalities for Formwork, Centering & Scaffolding for Isolated Foundation Upto Plinth 8% (I.No 1, 3rd Corrigendum and 2nd Addendum)Cum6780.196780.1952.48FalseNoneNoneFalseNoneFalse355824.37120
241288572217None2.4.3Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Item No.2.4.3 Vol-1 Pg No. 17 SR 2021-22) Additionalities for Formwork, Centering & Scaffolding for Plinth beams of Building 50% (I.No 1.a, 3rd Corrigendum and 2nd Addendum)Cum9437.49437.411.67FalseNoneNoneFalseNoneFalse110134.4580
241288772217None2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Item No.2.5.2 Vol-1 Pg No. 17 SR 2021-22) Additionalities for Formwork, Centering & Scaffolding for Beams & Lintels of Building 60% (I.No 12, 3rd Corrigendum and 2nd Addendum)Cum10392.4810392.4823.22FalseNoneNoneFalseNoneFalse241313.38560
241288972217None2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Item No.2.5.2 Vol-1 Pg No. 17 SR 2021-22) Additionalities for Formwork, Centering & Scaffolding for Columns 70% (I.No 8, 3rd Corrigendum and 2nd Addendum)Cum11042.0111042.018.65FalseNoneNoneFalseNoneFalse95513.38650
241289172217None2.5.2 Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Item No.2.5.2 Vol-1 Pg No. 17 SR 2021-22)Additionalities for Formwork, Centering & Scaffolding for Roof Slabs of Building 50% (I.No 13&14, 3rd Corrigendum and 2nd Addendum)Cum9742.959742.9539.88FalseNoneNoneFalseNoneFalse388548.8460
241289272217None14.1Supplying fitting & placing TMT bar reinforcement to superstructure complete as per Specifications ( Item No.14.1 Vol-3 Page No.103 SR 2021-22)MT92661.4592661.4511.06FalseNoneNoneFalseNoneFalse1024835.6370
241289472217None1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.(Page No.7 Vol-1 .I No. 1.9 SR 2021-22)Cum214.2214.2783.8FalseNoneNoneFalseNoneFalse167889.960
241289672217None5.4Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement: 6 coarse sand) (I No. 5.4, Vol-2 Pno . 9 SR 2021-22)Cum5619.65619.635.85FalseNoneNoneFalseNoneFalse201462.660
241289872217None6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.(I No. 6.32 Vol-2 P No. 17 SR 2021-22)Sqm1255.81255.8288.66FalseNoneNoneFalseNoneFalse362499.2280
241290072217None6.34Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of allmaterials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (Item no. 6.34 Vol-2 page no. 17 SR 2021-22)Sqm987.0987.071.21FalseNoneNoneFalseNoneFalse70284.270
241290272217None11.34 AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding7.12( Item No. 11.34 A Vol-2 Page no 85 SR 2021-22)Kg152.25152.25500.43FalseNoneNoneFalseNoneFalse76190.46750
241290472217None8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge For Ground Floor (Item No 8.1.1 Vol-2 page no 41 SR 2021-22 )Sqm223.65223.65191.98FalseNoneNoneFalseNoneFalse42936.3270
241290772217None8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge For Ground Floor (Item No 8.8 Vol-2 page no 42 SR 2021-22)Sqm322.35322.35201.66FalseNoneNoneFalseNoneFalse65005.1010
241290972217None8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge- For Ground Floor( Item No 8.4.2 Vol-2 page no 41 SR 2021-22 )Sqm275.1275.1563.5FalseNoneNoneFalseNoneFalse155018.850
241291172217None8.2.2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge-For Ground Floor ( Item No 8.2.2 Vol-2 page no 41 SR 2021-22)Sqm241.5241.549.65FalseNoneNoneFalseNoneFalse11990.4750
241291372217None9.17.2Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete do - Size of Tile 600x600 mm(Item No 9.17.2 Vol-2 page no 61 SR 2021-22 )Sqm1157.11157.1131.94FalseNoneNoneFalseNoneFalse152667.7740
241291572217None9.9Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete (Item No 9.9, Vol-2 Pg No- 60 SR 2021-22)Sqm635.25635.2510.3FalseNoneNoneFalseNoneFalse6543.0750
241291772217None9.38Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. (I.No.9.38 Vol-2 P.No.65 SR 2021-22)Sqm1022.771022.7732.42FalseNoneNoneFalseNoneFalse33158.20340
241291972217None9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalentFor Ground Floor (item No. 9.24 Vol-2 page no 63 SR 2021-22)Sqm3013.53013.569.85FalseNoneNoneFalseNoneFalse210492.9750
241292072217None12.113.1Providing and fixing CI Nahani trap of approved make conforming to ISI specifications and construction of Cistern in M-15 as per directions (Rate is inclusive of cost of materials and fixtures and conveyance of materials to work spot). - 10cms x 7.5cms ( Item No 12.113.1, pg no 90 of SR 2018-19)Each262.5262.54.0FalseNoneNoneFalseNoneFalse1050.00
241292272217None1.7Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 110mm dia., 6 kg/sqcm & class 3 (Vol-5, Pg. No. 134, Item No. 1.7 SR 2021-22)m413.7413.772.0FalseNoneNoneFalseNoneFalse29786.40
241292572217None2.2Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for: Pipes of SN4, 110mm dia. (Sl.No.2.2, SOR CODE M020B Vol-5 Page 134)m284.55284.5515.0FalseNoneNoneFalseNoneFalse4268.250
241292772217None2.4Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for: Pipes of SN4, 160mm dia. (Sl.No.2.4, SOR CODE M020D Vol-5 Page 134)m583.8583.836.0FalseNoneNoneFalseNoneFalse21016.80
241292972217NoneT130AConstructing brick masonry chamber of internal dimension 600x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover. (Sl.No.8, SOR CODE T130A Vol-5 Page 187)Nos4592.74592.72.0FalseNoneNoneFalseNoneFalse9185.40
241293072217NoneT130DConstructing brick masonry chamber of internal dimension 450x300mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover. (Sl.No.11, SOR CODE T130D Vol-5 Page 187)Nos3402.03402.02.0FalseNoneNoneFalseNoneFalse6804.00
241293172217None13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.(1st Corrigendum Vol-2 I.No 13.32.2)m391.65391.6532.0FalseNoneNoneFalseNoneFalse12532.80
241293272217None13.33.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work (1st Corrigendum Vol-2 I.No 13.33.3)m313.95313.9545.0FalseNoneNoneFalseNoneFalse14127.750
241293372217None13.33.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work (1st Corrigendum Vol-2 I.No 13.33.6)m737.1737.130.0FalseNoneNoneFalseNoneFalse22113.00
241293472217None2.2.1Point wiring using copper wire without switch : Supplying and wiring adopting loop system in existing PVC Conduit / casing caping using copper PVC insulated multi strand 2*1.5Sqmm copper wire with a 6Amps flush type SP control switch shall be fixed on the exisisting plastic sheet/ gang box, the othe ind of the wires shall be terminated with sufficient loose length in a wood/ PVC round block. complete for each outlet. Short point upto 3mtr form tapping point to out let via switch (Refer KPWD SR 2019/20 Page 5 Sl. No. 2.2.1)Point251.0251.010.0FalseNoneNoneFalseNoneFalse2510.00
241293572217None2.2.2Point wiring using copper wire without switch : Supplying and wiring adopting loop system in existing PVC Conduit / casing caping using copper PVC insulated multi strand 2*1.5Sqmm copper wire with a 6Amps flush type SP control switch shall be fixed on the exisisting plastic sheet/ gang box, the othe ind of the wires shall be terminated with sufficient loose length in a wood/ PVC round block. complete for each outlet. Medium point above 3Mtr upto 6mtr from tapping point to outlet via switch (Refer KPWD SR 2019/20 Page 5 Sl. No. 2.2.2)Point361.0361.030.0FalseNoneNoneFalseNoneFalse10830.00
241293672217None2.2.3Point wiring using copper wire without switch : Supplying and wiring adopting loop system in existing PVC Conduit / casing caping using copper PVC insulated multi strand 2*1.5Sqmm copper wire with a 6Amps flush type SP control switch shall be fixed on the exisisting plastic sheet/ gang box, the othe ind of the wires shall be terminated with sufficient loose length in a wood/ PVC round block. complete for each outlet. Long point above 6 mtr upto 10mtr from tapping point to out let via switch (Refer KPWD SR 2019/20 Page 5 Sl. No. 2.2.3)Point542.0542.020.0FalseNoneNoneFalseNoneFalse10840.00
241293772217None2.2.4Point wiring using copper wire without switch : Supplying and wiring adopting loop system in existing PVC Conduit / casing caping using copper PVC insulated multi strand 2*1.5Sqmm copper wire with a 6Amps flush type SP control switch shall be fixed on the exisisting plastic sheet/ gang box, the othe ind of the wires shall be terminated with sufficient loose length in a wood/ PVC round block. complete for each outlet. Two outlet in a row, above 3mtr upto 6mtr from tapping point to out let via switches .(Refer KPWD SR 2019/20 Page 5 Sl. No. 2.2.4)Point671.0671.02.0FalseNoneNoneFalseNoneFalse1342.00
241293872217None1.2.1Concealed Conduit System : Supplying….mm dia 2mm 2.5mm thick heavy gauge PVC conduit pipe with suitable size bends, metal/ PVC junction boxes adhesive paste etc., and running before concreting the salb. The conduit should be tied to the reinforecement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with18 SWG GI fish wire wherever necessary. 19/20mm dia 2mm thick (Refer KPWD SR 2019/20 Page 2 Sl. No. 1.2.1)m61.061.0450.0FalseNoneNoneFalseNoneFalse27450.00
241293972217None1.2.2Concealed Conduit System : Supplying….mm dia 2mm 2.5mm thick heavy gauge PVC conduit pipe with suitable size bends, metal/ PVC junction boxes adhesive paste etc., and running before concreting the salb. The conduit should be tied to the reinforecement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with18 SWG GI fish wire wherever necessary. 25mm dia 2mm thick (Refer KPWD SR 2019/20 Page 2 Sl. No. 1.2.2)m70.070.0300.0FalseNoneNoneFalseNoneFalse21000.00
241294072217None1.3.1Groove cutting : Supplying.dia 2mm/2.5mm thick heavy gauge PVC Conduit pope with bends, metal junction boxes adhesive paste etc., and bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever neccessary. 19/20mm dia 2mm thick (Refer KPWD SR 2019/20 Page 2 Sl. No. 1.3.1)m75.075.0150.0FalseNoneNoneFalseNoneFalse11250.00
241294172217None1.3.1Groove cutting : Supplying.dia 2mm/2.5mm thick heavy gauge PVC Conduit pope with bends, metal junction boxes adhesive paste etc., and bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever neccessary. 25mm dia 2m thick (Refer KPWD SR 2019/20 Page 2 Sl. No. 1.3.1)m75.075.0150.0FalseNoneNoneFalseNoneFalse11250.00
241294272217None1.3.3Groove cutting : Supplying.dia 2mm/2.5mm thick heavy gauge PVC Conduit pope with bends, metal junction boxes adhesive paste etc., and bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever neccessary. 32mm dia 2.5mm thick (Refer KPWD SR 2019/20 Page 2 Sl. No. 1.3.3)m80.080.025.0FalseNoneNoneFalseNoneFalse2000.00
241294372217None2.3.2Wiring for lighting/ power circuit using one of PVC insulated 1100v grade, multis and Copper conductor single core cable in open or concealed system of wiring. 1.5 sqmm (Refer KPWD SR 2019/20 Page 5 Sl. No. 2.3.2)m26.026.0450.0FalseNoneNoneFalseNoneFalse11700.00
241294472217None2.3.3Wiring for lighting/ power circuit using one of PVC insulated 1100v grade, multis and Copper conductor single core cable in open or concealed system of wiring. 2.5 sqmm (Refer KPWD SR 2019/20 Page 6 Sl. No. 2.3.3)m40.040.0950.0FalseNoneNoneFalseNoneFalse38000.00
241294572217None2.3.4Wiring for lighting/ power circuit using one of PVC insulated 1100v grade, multis and Copper conductor single core cable in open or concealed system of wiring. 4 sqmm (Refer KPWD SR 2019/20 Page 6 Sl. No. 2.3.4)m59.059.0700.0FalseNoneNoneFalseNoneFalse41300.00
241294672217None2.3.5Wiring for lighting/ power circuit using one of PVC insulated 1100v grade, multis and Copper conductor single core cable in open or concealed system of wiring.6 sqmm (Refer KPWD SR 2019/20 Page 6 Sl. No. 2.3.5)m87.087.0250.0FalseNoneNoneFalseNoneFalse21750.00
241294772217None1.5.119/20mm deep junction box (Refer KPWD SR 2019/20 Page 3 Sl. No. 1.5.1)Each49.049.010.0FalseNoneNoneFalseNoneFalse490.00
241294872217None1.5.225mm deep junction box (Refer KPWD SR 2014/15 Page 3 Sl. No. 1.5.2)Each51.051.02.0FalseNoneNoneFalseNoneFalse102.00
241294972217None1.12Supplying and fixing of Metal Fan Box with Round Hook. (Refer KPWD SR 2019/20 Page 3 Sl. No. 1.12)Each163.0163.015.0FalseNoneNoneFalseNoneFalse2445.00
241295072217None3.4.1Supplying and flush mounting powder coated / galvanised metal box suitable for mountting modular switch plates. The box should be firmly mounted after due groove cutting in Brick/Stone/C.C. wall 1 - 3 Way (Refer KPWD SR 2019/20 Page 9 Sl. No.3.4.1)Each123.0123.055.0FalseNoneNoneFalseNoneFalse6765.00
241295172217None3.4.3Supplying and flush mounting powder coated / galvanised metal box suitable for mountting modular switch plates. The box should be firmly mounted after due groove cutting in Brick/Stone/C.C. wall 6 Way (Refer KPWD SR 2019/20 Page 9 Sl. No.3.4.3)Each212.0212.010.0FalseNoneNoneFalseNoneFalse2120.00
241295272217None3.4.4Supplying and flush mounting powder coated / galvanised metal box suitable for mountting modular switch plates. The box should be firmly mounted after due groove cutting in Brick/Stone/C.C. wall 8 Way (Refer KPWD SR 2019/20 Page 9 Sl. No.3.4.4)Each250.0250.010.0FalseNoneNoneFalseNoneFalse2500.00
241295372217None3.4.5Supplying and flush mounting powder coated / galvanised metal box suitable for mountting modular switch plates. The box should be firmly mounted after due groove cutting in Brick/Stone/C.C. wall 10-12 Way (Refer KPWD SR 2019/20 Page 9 Sl. No.3.4.5)Each325.0325.05.0FalseNoneNoneFalseNoneFalse1625.00
241295472217None3.4.6Supplying and flush mounting powder coated / galvanised metal box suitable for mountting modular switch plates. The box should be firmly mounted after due groove cutting in Brick/Stone/C.C. wall 16-18 Way (Refer KPWD SR 2019/20 Page 9 Sl. No.3.4.6)Each355.0355.01.0FalseNoneNoneFalseNoneFalse355.00
241295572217None3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 3 Module (Refer KPWD SR 2019/20 Page 9 Sl. No.3.5.1)Each152.0152.030.0FalseNoneNoneFalseNoneFalse4560.00
241295672217None3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module ( Refer KPWD SR 2019/20 Page 9 Sl. No.3.5.3Each244.0244.010.0FalseNoneNoneFalseNoneFalse2440.00
241295772217None3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module (Refer KPWD SR 2019/20 Page 9 Sl. No.3.5.4)Each302.0302.010.0FalseNoneNoneFalseNoneFalse3020.00
241295872217None3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module (Refer KPWD SR 2019/20 Page 9 Sl. No.3.5.5)Each363.0363.05.0FalseNoneNoneFalseNoneFalse1815.00
241295972217None3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 16-18 Module (Refer KPWD SR 2019/20 Page 9 Sl. No.3.5.6)Each402.0402.01.0FalseNoneNoneFalseNoneFalse402.00
241296072217None3.6.1Supplying and fixing of Modular Switch / Socket / Stepped type electronic fan regulator / dimmer / telephone socket etc on existing modular Switch Plate. IS 3854 & IS 1293. 6A one way (Refer KPWD SR 2019/20 Page 10 Sl. No.3.6.1)Each88.088.085.0FalseNoneNoneFalseNoneFalse7480.00
241296172217None3.6.2Supplying and fixing of Modular Switch / Socket / Stepped type electronic fan regulator / dimmer / telephone socket etc on existing modular Switch Plate. IS 3854 & IS 1293. 6A two way (Refer KPWD SR 2019/20 Page 10 Sl. No.3.6.2)Each152.0152.02.0FalseNoneNoneFalseNoneFalse304.00
241296272217None3.6.3Supplying and fixing of Modular Switch / Socket / Stepped type electronic fan regulator / dimmer / telephone socket etc on existing modular Switch Plate. IS 3854 & IS 1293. 6A three way socket. (Refer KPWD SR 2019/20 Page 10 Sl. No.3.6.3)Each162.0162.035.0FalseNoneNoneFalseNoneFalse5670.00
241296372217None3.6.4Supplying and fixing of Modular Switch / Socket / Stepped type electronic fan regulator / dimmer / telephone socket etc on existing modular Switch Plate. IS 3854 & IS 1293. Stepped Fan Regulator. (Refer KPWD SR 2019/20 Page 10 Sl. No.3.6.4)Each313.0313.015.0FalseNoneNoneFalseNoneFalse4695.00
241296472217None3.6.8Supplying and fixing of Modular Switch / Socket / Stepped type electronic fan regulator / dimmer / telephone socket etc on existing modular Switch Plate. IS 3854 & IS 1293. 16A one way switch.(Refer KPWD SR 2019/20 Page 10 Sl. No.3.6.8)Each249.0249.010.0FalseNoneNoneFalseNoneFalse2490.00
241296572217None3.6.9Supplying and fixing of Modular Switch / Socket / Stepped type electronic fan regulator / dimmer / telephone socket etc on existing modular Switch Plate. IS 3854 & IS 1293. 6Amps Bell Push switch .(Refer KPWD SR 2019/20 Page 10 Sl. No.3.6.9)Each159.0159.04.0FalseNoneNoneFalseNoneFalse636.00
241296672217None3.6.11Supplying and fixing of Modular Switch / Socket / Stepped type electronic fan regulator / dimmer / telephone socket etc on existing modular Switch Plate. IS 3854 & IS 1293. 6/16A Universal Socket.(Refer KPWD SR 2019/20 Page 10 Sl. No.3.6.11)Each249.0249.010.0FalseNoneNoneFalseNoneFalse2490.00
241296772217None3.6.12Supplying and fixing of Modular Switch / Socket / Stepped type electronic fan regulator / dimmer / telephone socket etc on existing modular Switch Plate. IS 3854 & IS 1293. TV/Telephone Socket .(Refer KPWD SR 2019/20 Page 10 Sl. No.3.6.12)Each147.0147.020.0FalseNoneNoneFalseNoneFalse2940.00
241296872217None3.14.8Supplying and fixing of Modular Switch / Socket / Stepped type electronic fan regulator / dimmer / telephone socket etc on existing modular Switch Plate. IS 3854 & IS 1293. 6Amps Bell Buzzer .(Refer KPWD SR 2019/20 Page 11 Sl. No.3.14.8)Each123.0123.04.0FalseNoneNoneFalseNoneFalse492.00
241296972217None3.14.10Supplying and fixing of Modular Switch / Socket / Stepped type electronic fan regulator / dimmer / telephone socket etc on existing modular Switch Plate. IS 3854 & IS 1293. 32A DP switch.(Refer KPWD SR 2019/20 Page 11 Sl. No.3.14.10)Each108.0108.06.0FalseNoneNoneFalseNoneFalse648.00
241297072217None5.17.1Supplying and fixing miniature circuit breaker on existing MCB distribution board using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring confirming to IEC 60898. 5 - 32 Amps SP (Refer KPWD SR 2019/20 Page 27 Sl. No. 5.17.1)Each523.0523.015.0FalseNoneNoneFalseNoneFalse7845.00
241297172217None5.17.7Supplying and fixing miniature circuit breaker on existing MCB distribution board using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring confirming to IEC 60898. 6-32 Amps TPN (Refer KPWD SR 2019/20 Page 27 Sl. No. 5.17.7)Each1777.01777.01.0FalseNoneNoneFalseNoneFalse1777.00
241297272217None5.17.4Supplying and fixing miniature circuit breaker on existing MCB distribution board using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring confirming to IEC 60898. 6-32 Amps DP (Refer KPWD SR 2019/20 Page 27 Sl. No. 5.17.4)Each909.0909.01.0FalseNoneNoneFalseNoneFalse909.00
241297372217None5.19.8Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board. 32Amps,4 Pole (Refer KPWD SR 2019/20 Page 28 Sl. No5.19.8)Each4677.04677.01.0FalseNoneNoneFalseNoneFalse4677.00
241297472217None5.18.8Supplying and fixing regular MCB distribution board on wall/ flush mounting using required clamps, bolts, nuts, etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase/ single door with powder coated painting etc., complete. Made out of 14 SWG MS enclosure. 8 way TP & N (Refer KPWD SR 2014/15 Page 28 Sl. No. 5.18.11) 12 way SPN (Refer KPWD SR 2019/20 Page 28 Sl. No. 5.18.8)Each1695.01695.01.0FalseNoneNoneFalseNoneFalse1695.00
241297572217None5.18.9Supplying and fixing regular MCB distribution board on wall/ flush mounting using required clamps, bolts, nuts, etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase/ single door with powder coated painting etc., complete. Made out of 14 SWG MS enclosure. 8 way TP & N (Refer KPWD SR 2014/15 Page 28 Sl. No. 5.18.11) 4 way TPN (Refer KPWD SR 2019/20 Page 28 Sl. No. 5.18.9)Each2067.02067.01.0FalseNoneNoneFalseNoneFalse2067.00
241297672217None14.7.1Fixing all types and all capacities of flouroscent / false ceiling / spot light / CFL / LED fittings on the wall / ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required nos. of round blocks & clamps. On wall / ceiling / rafter / girders. (Refer KPWD SR 2019/20 Page 79 Sl. No.14.7.1)Each110.0110.035.0FalseNoneNoneFalseNoneFalse3850.00
241297772217None14.8Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps ceiling rose, necessary length of 23/0.0076 inch PVC insulated twin twisted copper wire and wiring. (Refer KPWD SR 2019/20 Page 80 Sl. No.14.8)Each150.0150.015.0FalseNoneNoneFalseNoneFalse2250.00
241297872217None14.5Fixing all types and Fixing halegen/LED/MH/svl/il/led FLOOD LIGHT FITTING on existing Pole /wall ceiling including lamps ,blts,nuts and wiring usiing suitable capacity wires (Refer KPWD SR 2019/20 Page 79 Sl. No.14.5)Each175.0175.02.0FalseNoneNoneFalseNoneFalse350.00
241297972217None14.12Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and coloring to match the existing wall or brackets with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame if required.(Refer KPWD SR 2019/20 Page 80 Sl. No.14.12)Each400.0400.04.0FalseNoneNoneFalseNoneFalse1600.00
241298072217None6.2Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipments on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit … The pit should be filled with equal proprotion of salt and charcoal 150mm alround the pipe to complete depth. The connection from the pipe to the conduit etc, is to be established through GI wire of size as per ISI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and checknuts etc, the pipe shall have 16 through holes of 122 mm dia - (Refer KPWD SR 2019/20 Page 40 Sl. No. 6.2)Set4150.04150.02.0FalseNoneNoneFalseNoneFalse8300.00
241298172217None6.3.125x3mm GI strip ( (Refer KPWD SR 2019/20 Page 40Sl. No. 6.3.1)m75.075.020.0FalseNoneNoneFalseNoneFalse1500.00
241298272217None6.18.68 SWG copper wire (Refer KPWD SR 2019/20 Page 44 Sl. No. 6.18.6)m105.0105.020.0FalseNoneNoneFalseNoneFalse2100.00
241298372217None6.4.5Supplying 1.1KV LT UG cable having aluminium conductor PVC insulated, extruded inner sheathed, galvanised, steel strips : 3.5 core 25 sqmm (Refer KPWD SR 2019/20 Page 40 Sl. No.6.4.5)m180.0180.0100.0FalseNoneNoneFalseNoneFalse18000.00
241298472217None6.5.2Labour charges for laying of 1.1 KV class UG cable existing trench GI pipe / stoneware pipe / on wall / on pole as required. In existing trench / duct In existing trench / duct 6 sq mm to 25 sqmm (Refer KPWD SR 2019/20 Page 41 Sl. No. 6.5.2)m15.515.5100.0FalseNoneNoneFalseNoneFalse1550.00
241298572217None6.11.3Supply and fixing of heavy duty cable glands suitable for UG Cables of 1.1 KV Class. (metal only) 32mm (Refer KPWD SR 2019/20 Page 42 Sl. No. 6.11.3Nos117.0117.04.0FalseNoneNoneFalseNoneFalse468.00
241298672217None6.17.6Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 16 sq.mm (Refer KPWD SR 2019/20 Page 43 Sl. No. 6.17.6)Nos12.4412.4415.0FalseNoneNoneFalseNoneFalse186.60
241298772217None6.61Digging of trench of 0.6m deep x 0.5m wide refilling the trench to the required ground level, consolidating etc. complete. In Soil.-ordinary (Refer KPWD SR 2019/20 Page 41Sl. No.6.61)m76.076.050.0FalseNoneNoneFalseNoneFalse3800.00
241298872217None7.20.1Supply and laying double walled corrugated( DWC) HDPE Pipe with necessary connecting Sockets/ Coupling /Tees/Bends of same materials in existing trench as per IS 14930 part -II suitable for drawing under ground cables - 40 mm ( Page 63 Sl. No.7.20.1)m98.098.0100.0FalseNoneNoneFalseNoneFalse9800.00
241298972217None9.3Supply and drawing PVC Insulated Gas Injected Physical foam jellly flooded c-axial TV cable.RG.6 (Refer KPWD SR 2019/20 Page 54 Sl. No. 9.3)Rmtr35.035.0300.0FalseNoneNoneFalseNoneFalse10500.00
241299072217None9.2.2Supply and drawing PVCflexible One Pair Telephone unarmoured tinned copper cable (Refer KPWD SR 2019/20 Page 54 Sl. No. 9.2.2)Rmtr14.514.5300.0FalseNoneNoneFalseNoneFalse4350.00
241299172217None13.46Supply and fixing of 70-150watt lamp Holder (Refer KPWD SR 2019/20 Page 78 Sl. No. 13.46)No106.0106.05.0FalseNoneNoneFalseNoneFalse530.00
241299272217None14.1.2Supply and fixing of - mm dia class A pipe bracket up to 2mtrs using 32mm dia GI pipe (Refer KPWD SR 2019/20 Page 79 Sl. No. 14.1.2)Each835.0835.02.0FalseNoneNoneFalseNoneFalse1670.00
241299372217None5.14.7Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. C curve ,indicator ON/OFF ,energy cross 3 with short circuit breaking capacity of 10k and complete wiring as required 63 /100Amps ,25KA, FP for Panel EB Incomer (Refer KPWD SR 2019/20 Page 27 Sl. No. 5.14.7)Each8265.08265.01.0FalseNoneNoneFalseNoneFalse8265.00
241299472217None5.17.7Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. C curve ,indicator ON/OFF ,energy cross 3 with short circuit breaking capacity of 10k and complete wiring as required 6-32 Amps TPN (Refer KPWD SR 2019/20 Page 27 Sl. No. 5.17.7)Each1777.01777.01.0FalseNoneNoneFalseNoneFalse1777.00
241299572217None5.9.2Supplying and fixing HRC Fuse unit base on existing switch/panel board - Up to 63A (Refer KPWD SR 2019/20 Page 25 Sl. No.5.9.2)Each270.0270.01.0FalseNoneNoneFalseNoneFalse270.00
241299672217None5.40.1Supplying 100. Amps rated 3 phase with neutral bus bar using requirement capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/ DMC insulator which are mounted on powder coated 40*6mm M.S flat frame work in exisisting panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. : 100Amps 4x30x6mm Alluminium Strips - 100Amps , 4x50x10xmm AL strips (Refer KPWD SR 2019/20 Page 30 Sl. No. 5.40.1)m2214.02214.02.0FalseNoneNoneFalseNoneFalse4428.00
241299772217None5.40.2Supplying and fixing angle iron frame work fabricated out of M.S. angle iron. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. - 50x50x6mm (Refer KPWD SR 2019/20 Page 30 Sl. No. 5.40.2)m3078.03078.05.0FalseNoneNoneFalseNoneFalse15390.00
241299872217None5.42.1Fabricating supplying and mounting MS box made out 14 SWG suitable for floor/ wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with glad and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled meta paint etc., complete. (Refer KPWD SR 2019/20 Page 30 Sl. No. 5.42.1) (Approximate size 0.6 Mtr x0.6 Mtr x0.45mtr)Sqm0.430.4335000.0FalseNoneNoneFalseNoneFalse15050.00
241299972217None5.30Supplying of and fixing Trivector Meter suitable of for operation suitable for 5 to 20A single phase opeartion class-1 ,accuracy with temper proff energy meter (Refer KPWD SR 2019/20 Page 29 Sl. No. 5.30)Set1242.01242.01.0FalseNoneNoneFalseNoneFalse1242.00
241300072217None5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C. .(Refer KPWD SR 2019/20Page 29 Sl. No.5.38)Each464.0464.03.0FalseNoneNoneFalseNoneFalse1392.00
241300172217None5.11.1Supply of onload Change Over switches 4 poles, AC -23A duty ,415V AC supply - 63A (Refer KPWD SR 2019/20 Page 25 Sl. No. 5.11.1)Each5185.05185.01.0FalseNoneNoneFalseNoneFalse5185.00
241300272217None5.21Supplying and fixing of and wiring earth leakage relay with core balanced Current Transformer suitable for single phase 50Hz AC with latest microcontroller based ,digital readout (Refer KPWD SR 2019/20 Page 28 Sl. No.5.21)Each8316.08316.01.0FalseNoneNoneFalseNoneFalse8316.00
241300372217None12.2.1Supplying - feet - PVC batten with integrated LED tube - watt with high quality deffuser with life of 25000 burning hours &70% lumen maintenence with CRI .2 year warranty againest any manufacturing defect - LED light fitting 1 x2' -9/10watt - (Refer KPWD SR 2019/20 Page 64 Sl. No.12.2.1) - Common areaEach239.0239.010.0FalseNoneNoneFalseNoneFalse2390.00
241300472217None12.2.2Supplying - feet - PVC batten with integrated LED tube - watt with high quality deffuser with life of 25000 burning hours &70% lumen maintenence with CRI .2 year warranty againest any manufacturing defect - LED light fitting 1 x4' -20/22watt - (Refer KPWD SR 2019/20 Page 64 Sl. No.12.2.2)Each422.0422.030.0FalseNoneNoneFalseNoneFalse12660.00
241300572217None7.3.1Supplying 48" Sweep (1200mm)capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles, Single phase AC supply conforming ot ISS-374-1979 and with double ball bearing system. (Refer KPWD SR 2019/20 Page 46 Sl. No.7.3.1)Each2090.02090.015.0FalseNoneNoneFalseNoneFalse31350.00
241300672217None12.8.3Supply of LED Streetlight 70 watts. (Refer KPWD SR 2019/20 Page 67 Sl. No. 12.8.3)Each5480.05480.02.0FalseNoneNoneFalseNoneFalse10960.00
241300772217None12.11.5Supply and fixing of LED Bulb - 12 watt (Refer KPWD SR 2019/20 Page 68 Sl. No. 12.11.5)Each165.0165.05.0FalseNoneNoneFalseNoneFalse825.00
241300872217None7.1Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable for operate on 230V 50Hz, AC supply. (Refer KPWD SR 2019/20 Page 46 Sl. No.7.1)Each1200.01200.04.0FalseNoneNoneFalseNoneFalse4800.00
17069400400000NoneNoneOther WorksRearing Pond37129808.52
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
241300972218Volume -1-Common SR- Chapter - I- Earth Work1.14.1In all kinds of soils Depth upto 3 mCum73.076.6550522.39FalseNoneNoneFalseNoneFalse3872541.19350
241301172218Volume -1-Common SR- Chapter - I- Earth Work1.8Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.Cum402.0422.12976.57FalseNoneNoneFalseNoneFalse1256410.1970
241301072218NoneA130AProviding and Filling in foundation with granite / trap broken metal 100mm and down size with approved M-Sand including hand packing, ramming, watering including cost of all materials and labour with all lead and lift complete as per specifications. (Pg. No. 64 SOR Code A130A SR 2021-22 V- 5)Cum1672.651672.65845.35FalseNoneNoneFalseNoneFalse1413974.67750
241301272218None2.1.2Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8 (M5) Using 40 mm nominal size graded crushed coarse aggregates. (Vol-1, Pg. No.15, Item No. 2.1.2, SR 2021-22)Cum5466.35466.3634.01FalseNoneNoneFalseNoneFalse3465688.8630
241301372218None3.25Providing cohesive non-swelling (CNS) soil lining to canals using soil from approved borrow area including cost of all materials ,labour,machinery,spreading soil in layers of thicknessnot more than 150mm breaking clods,levelling ,watering, compacting to density control of not less than95 percent or as stipulated dressing to required profile etc.complete with lead upto 1 km and all lifts(WRD SR 2018-19 It No 3.25)Cum256.2256.22232.43FalseNoneNoneFalseNoneFalse571948.5660
241301472218None9.3Supplying, Fitting and Placing TMT Fe 500 & above Reinforcement in Foundation / Substructure / Superstructure complete as per Drawing and Technical Specifications. (Vol-3, Pg. No.71, Item No. 9.3, SR 2021-22)MT84311.8584311.85114.98FalseNoneNoneFalseNoneFalse9694176.5130
241301572218None2.4.2Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Vol-I, Pg. No.17, Item No. 2.4.2, SR 2021-22)Cum6893.046893.042160.25FalseNoneNoneFalseNoneFalse14890689.660
241301672218None9.0Providing and laying woven polypropylene multi filament yarn geosynthetic mat with opening size of 75 microns (0.075 mm) and water permeability more than 9 liters/sqm/second to retain D85/D10 grain size of particles to the formation, grade and level as per drawing including cost of all materials, conveyance of all materials and labour, stiching, making loop at ends etc. complete with all incidental charges for successful completion of work as per the direction of Engineer-in-charge of work. (Pg. No. 2 I.No 9 SR 2021-22 V- 7 )Sqm133.35133.3514731.0FalseNoneNoneFalseNoneFalse1964378.850
17069400410001NoneNoneOther WorksBruders Pond7479776.84
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
241301772219Volume -1-Common SR- Chapter - I- Earth Work1.14.1In all kinds of soils Depth upto 3 mCum73.076.655712.03FalseNoneNoneFalseNoneFalse437827.09950
241301972219Volume-1- Common SR-Chapter -II - Concrete Works2.1.2Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregatesCum5364.05632.273.12FalseNoneNoneFalseNoneFalse411826.4640
241302172219Volume -1-Common SR- Chapter - I- Earth Work1.8Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.Cum402.0422.1277.43FalseNoneNoneFalseNoneFalse117103.2030
241302372219Volume-3-For Roads And Bridges - Chapter-2-Site Clearance2.1.A.iGirth from 300 mm to 600 mmeach469.0492.45500.0FalseNoneNoneFalseNoneFalse246225.00
241302572219Volume-3-For Roads And Bridges - Chapter-2-Site Clearance2.5.ii.BIn area of thorny jungleha168586.0177015.36.3FalseNoneNoneFalseNoneFalse1115196.390
241302772219Volume -1-Common SR- Chapter - I- Earth Work1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth Cum65.068.2521000.0FalseNoneNoneFalseNoneFalse1433250.00
241301872219NoneA130AProviding and Filling in foundation with granite / trap broken metal 100mm and down size with approved M-Sand including hand packing, ramming, watering including cost of all materials and labour with all lead and lift complete as per specifications. (Pg. No. 64 SOR Code A130A SR 2021-22 V- 5)Cum1672.651672.6597.49FalseNoneNoneFalseNoneFalse163066.64850
241302072219None4.31Providing cohesive non-swelling (CNS) soil lining to canals using soil from approved borrow area including cost of all materials ,labour,machinery,spreading soil in layers of thicknessnot more than 150mm breaking clods,levelling ,watering, compacting to density control of not less than95 percent or as stipulated dressing to required profile etc.complete with lead upto 1 km and all lifts(MI SR 2018-19 PNo 16 It No4.31)Cum256.2256.2208.07FalseNoneNoneFalseNoneFalse53307.5340
241302272219None9.3Supplying, Fitting and Placing TMT Fe 500 & above Reinforcement in Foundation / Substructure / Superstructure complete as per Drawing and Technical Specifications. (Vol-3, Pg. No.71, Item No. 9.3, SR 2021-22)MT84311.8584311.8511.48FalseNoneNoneFalseNoneFalse967900.0380
241302472219None2.4.2Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Vol-I, Pg. No.17, Item No. 2.4.2, SR 2021-22)Cum6893.046893.04278.58FalseNoneNoneFalseNoneFalse1920263.08320
241302672219None9.0Providing and laying woven polypropylene multi filament yarn geosynthetic mat with opening size of 75 microns (0.075 mm) and water permeability more than 9 liters/sqm/second to retain D85/D10 grain size of particles to the formation, grade and level as per drawing including cost of all materials, conveyance of all materials and labour, stiching, making loop at ends etc. complete with all incidental charges for successful completion of work as per the direction of Engineer-in-charge of work. (Pg. No. 2 I.No 9 SR 2021-22 V- 7 )Sqm133.35133.354603.01FalseNoneNoneFalseNoneFalse613811.38350
17069400410000NoneNoneOther WorksStorage Tank6622916.39
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
241302872220Volume -1-Common SR- Chapter - I- Earth Work1.14.1In all kinds of soils Depth upto 3 mCum73.076.654419.31FalseNoneNoneFalseNoneFalse338740.11150
241303072220Volume -1-Common SR- Chapter - I- Earth Work1.8Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.Cum402.0422.1116.71FalseNoneNoneFalseNoneFalse49263.2910
241303272220Volume -3-For Roads And Bridges - Chapter - 13 - Sub-Structure13.7Providing and laying of Filter media with granular materials/ stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and Technical Specification.Cum1105.01160.25118.18FalseNoneNoneFalseNoneFalse137118.3450
241302972220NoneA130AProviding and Filling in foundation with granite / trap broken metal 100mm and down size with approved M-Sand including hand packing, ramming, watering including cost of all materials and labour with all lead and lift complete as per specifications. (Pg. No. 64 SOR Code A130A SR 2021-22 V- 5)Cum1672.651672.65320.08FalseNoneNoneFalseNoneFalse535381.8120
241303172220None2.1.2Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness,well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8 (M5) Using 40 mm nominal size graded crushed coarse aggregates. (Vol-1, Pg. No.15, Item No. 2.1.2, SR 2021-22)Cum5466.35466.3240.06FalseNoneNoneFalseNoneFalse1312239.9780
241303372220None4.31Providing cohesive non-swelling (CNS) soil lining to canals using soil from approved borrow area including cost of all materials ,labour,machinery,spreading soil in layers of thicknessnot more than 150mm breaking clods,levelling ,watering, compacting to density control of not less than95 percent or as stipulated dressing to required profile etc.complete with lead upto 1 km and all lifts(MI SR 2018-19 PNo 16 It No4.31)Cum256.2256.287.53FalseNoneNoneFalseNoneFalse22425.1860
241303472220None9.3Supplying, Fitting and Placing TMT Fe 500 & above Reinforcement in Foundation / Substructure / Superstructure complete as per Drawing and Technical Specifications. (Vol-3, Pg. No.71, Item No. 9.3, SR 2021-22)MT84311.8584311.8516.4FalseNoneNoneFalseNoneFalse1382714.340
241303572220None2.4.2Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Vol-I, Pg. No.17, Item No. 2.4.2, SR 2021-22)Cum6893.046893.04412.74FalseNoneNoneFalseNoneFalse2845033.32960
17069400410000NoneNoneOther WorksHatchery1938017.74
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
241303772221Volume -1-Common SR- Chapter - I- Earth Work1.14.1In all kinds of soils Depth upto 3 mCum73.076.651361.21FalseNoneNoneFalseNoneFalse104336.74650
241303972221Volume-2-For Buildings Chapter-8-Finishing8.12Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineerin-Charge.kg51.053.55352.86FalseNoneNoneFalseNoneFalse18895.6530
241304072221Volume-2-For Buildings Chapter-8-Finishing8.25Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm105.0110.25352.86FalseNoneNoneFalseNoneFalse38902.8150
241304272221Volume-2-For Buildings Chapter-13-Water Suppy & Drainage Works13.4.450 mm nominal boreNos.834.0875.712.0FalseNoneNoneFalseNoneFalse10508.40
241304472221Volume-2-For Buildings Chapter-13-Water Suppy & Drainage Works13.4.680 mm nominal boreNos.2056.02158.824.0FalseNoneNoneFalseNoneFalse51811.20
241304672221Volume-2-For Buildings Chapter-13-Water Suppy & Drainage Works13.7.115 mm nominal boreNos.239.0250.95120.0FalseNoneNoneFalseNoneFalse30114.00
241304872221Volume -3-For Roads And Bridges - Chapter - 16 -River Training And Protection Works16.4.AProviding and laying Pitching on slopes laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and Technical specifications Stone/BoulderCum1635.01716.7553.7FalseNoneNoneFalseNoneFalse92189.4750
241303672221NoneA130AProviding and Filling in foundation with granite / trap broken metal 100mm and down size with approved M-Sand including hand packing, ramming, watering including cost of all materials and labour with all lead and lift complete as per specifications. (Pg. No. 64 SOR Code A130A SR 2021-22 V- 5)Cum1672.651672.6593.96FalseNoneNoneFalseNoneFalse157162.1940
241303872221None2.1.2Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8 (M5) Using 40 mm nominal size graded crushed coarse aggregates. (Vol-1, Pg. No.15, Item No. 2.1.2, SR 2021-22)Cum5466.35466.346.98FalseNoneNoneFalseNoneFalse256806.7740
241304172221None9.3Supplying, Fitting and Placing TMT Fe 500 & above Reinforcement in Foundation / Substructure / Superstructure complete as per Drawing and Technical Specifications. (Vol-3, Pg. No.71, Item No. 9.3, SR 2021-22)MT84311.8584311.852.84FalseNoneNoneFalseNoneFalse239445.6540
241304372221None2.4.2Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications, M20 Design Mix using 20mm nominal size graded crushed coarse agregate. (The cost of steel reinforcement & formwork to be paid separately) Additionalities for Formwork, Centering & Scaffolding Canal Lining 10% (Vol-1, Pg. No.119, Item No. 10, SR 2021-22) (Vol-1, Pg. No.17, Item No. 2.4.2, SR 2021-22)Cum6893.046893.0459.09FalseNoneNoneFalseNoneFalse407309.73360
241304572221None1.7Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:PVC pipes 110mm dia., 6 kg/sqcm & class 3. (Vol-5 lt.No.1.7 P.No.134 /2021-22)Rmtr413.7413.7120.0FalseNoneNoneFalseNoneFalse49644.00
241304772221None2.5Providing, Laying and Fixing GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For Medium Duty GI pipe of 100mm dia (Vol-5 lt.No.2.5 P.No.142/2021-22)Rmtr376.95376.95188.16FalseNoneNoneFalseNoneFalse70926.9120
241304972221None1.8Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:PVC pipes 140mm dia., 6 kg/sqcm & class 3. (Vol-5 lt.No.1.8 P.No.134 /2021-22)Rmtr595.35595.35100.0FalseNoneNoneFalseNoneFalse59535.00
241305072221None2.1.4Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates (Vol-1, Pg No. 15 It No. 2.1.4. SR 2021-22)Cum6014.46014.428.08FalseNoneNoneFalseNoneFalse168884.3520
241305172221None11.34BProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc.(Vol-2, Pg. No.85, Item No. 11.34B, SR 2021-22)Kg164.85164.85302.4FalseNoneNoneFalseNoneFalse49850.640
241305272221None8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Vol-2, Pg. No.41, Item No. 8.4.2, SR 2021-22)Sqm275.1275.1352.86FalseNoneNoneFalseNoneFalse97071.7860
241305372221None13.33.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. 25mm nominal dia Pipes (Vol-2, Item No. 13.33.3, SR 2021-22 1st Corrigenda )Rmtr313.95313.95110.28FalseNoneNoneFalseNoneFalse34622.4060
17069400410000NoneNoneOther WorksBattery Pond1613351.91
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
241305472222Volume -1-Common SR- Chapter - I- Earth Work1.14.1In all kinds of soils Depth upto 3 mCum73.076.65627.59FalseNoneNoneFalseNoneFalse48104.77350
241305672222Volume -1-Common SR- Chapter - I- Earth Work1.1Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications Cum122.0128.190.27FalseNoneNoneFalseNoneFalse11563.5870
241305572222NoneA130AProviding and Filling in foundation with granite / trap broken metal 100mm and down size with approved M-Sand including hand packing, ramming, watering including cost of all materials and labour with all lead and lift complete as per specifications. (Pg. No. 64 SOR Code A130A SR 2021-22 V- 5)Cum1672.651672.6571.72FalseNoneNoneFalseNoneFalse119962.4580
241305772222None2.1.2Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8 (M5) Using 40 mm nominal size graded crushed coarse aggregates. (Vol-1, Pg. No.15, Item No. 2.1.2, SR 2021-22)Cum5831.75831.735.86FalseNoneNoneFalseNoneFalse209124.7620
241305872222None9.3Supplying, Fitting and Placing TMT Fe 550 & above Reinforcement in Foundation / Substructure / Superstructure complete as per Drawing and Technical Specifications. (Vol-3, Pg. No.71, Item No. 9.3, SR 2021-22)MT84311.8584311.855.69FalseNoneNoneFalseNoneFalse479734.42650
241305972222None2.4.2Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix using 20mm nominal size graded crushed coarse agregate Additionalities for Formwork, Centering & Scaffolding Earth retaining structure 10% (Vol-1, Pg. No.119, Item No. 9, SR 2021-22) (The cost of steel reinforcement & formwork to be paid separately) (Vol-1, Pg. No.17, Item No. 2.4.2, SR 2021-22)Cum6893.046893.04108.06FalseNoneNoneFalseNoneFalse744861.90240
17069400410000NoneNoneOther WorksPacking Shed2226337.79
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
241306072223Volume -1-Common SR- Chapter - I- Earth Work1.14.1In all kinds of soils Depth upto 3 mCum73.076.65880.69FalseNoneNoneFalseNoneFalse67504.88850
241306272223Volume-2-For Buildings Chapter-9-Flooring9.4Providing and laying Cement concrete pavement with 1:2:4 for commercial & residential building floors, hardpaths, footpaths using 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size, including finishing complete as per Engineer incharge.Cum6200.06510.04.66FalseNoneNoneFalseNoneFalse30336.60
241306472223Volume-2-For Buildings Chapter-11-Steel and Aluminium Work11.16.2Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.kg136.0142.84319.12FalseNoneNoneFalseNoneFalse616770.3360
241306672223Volume-2-For Buildings Chapter-7-Roofing7.38Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per Sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.Sqm556.0583.8246.05FalseNoneNoneFalseNoneFalse143643.990
241306972223Volume-2-For Buildings Chapter-7-Roofing7.39.1Ridges plain (500 - 600mm)m361.0379.0526.4FalseNoneNoneFalseNoneFalse10006.920
241307072223Volume-2-For Buildings Chapter-8-Finishing8.4Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm90.094.5157.17FalseNoneNoneFalseNoneFalse14852.5650
241307272223Volume-2-For Buildings Chapter-6-Masonry works6.6Providing Brick work with common burnt clay machine moulded perforated bricks of class designation 5.0 conforming to IS: 2222 in superstructure above plinth level in cement mortar 1:6 (1 cement : 6 coarse sand) With Modular bricks including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum9608.010088.47.92FalseNoneNoneFalseNoneFalse79900.1280
241307472223Volume-2-For Buildings Chapter-8-Finishing8.4.1Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm282.0296.1171.65FalseNoneNoneFalseNoneFalse50825.5650
241307572223Volume -1-Common SR- Chapter - I- Earth Work1.1Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications Cum122.0128.186.4FalseNoneNoneFalseNoneFalse11067.840
241307672223Volume-2-For Buildings Chapter-8-Finishing8.28Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 Sqm) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm66.069.3171.65FalseNoneNoneFalseNoneFalse11895.3450
241307772223Volume-2-For Buildings Chapter-17-Rain Water Harvesting17.1Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.Cum960.01008.0375.0FalseNoneNoneFalseNoneFalse378000.00
241307872223Volume-2-For Buildings Chapter-17-Rain Water Harvesting17.2Supplying, filling, spreading &leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.Cum372.0390.6375.0FalseNoneNoneFalseNoneFalse146475.00
241306172223NoneA130AProviding and Filling in foundation with granite / trap broken metal 100mm and down size with approved M-Sand including hand packing, ramming, watering including cost of all materials and labour with all lead and lift complete as per specifications. (Pg. No. 64 SOR Code A130A SR 2021-22 V- 5)Cum1672.651672.6526.94FalseNoneNoneFalseNoneFalse45061.1910
241306372223None2.1.2Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8 (M5) Using 40 mm nominal size graded crushed coarse aggregates. (Vol-1, Pg. No.15, Item No. 2.1.2, SR 2021-22)Cum5466.35466.326.94FalseNoneNoneFalseNoneFalse147262.1220
241306572223None9.3Supplying, Fitting and Placing TMT Fe 550 & above Reinforcement in Foundation / Substructure / Superstructure complete as per Drawing and Technical Specifications. (Vol-3, Pg. No.71, Item No. 9.3, SR 2021-22)MT84311.7884311.780.78FalseNoneNoneFalseNoneFalse65763.18840
241306772223None2.2.1.1Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with 20% partial replacement with Recycled concrete aggregate (RCA) (Vol-1, Pg. No.15, Item No. 2.2.1.1, SR 2021-22) Additionalities for Formwork, Centering & Scaffolding Foundation upto Plinth 8% (Vol-1, Pg. No.119, Item No. 8, SR 2021-22)Cum6739.366739.3620.25FalseNoneNoneFalseNoneFalse136472.040
241306872223None5.4Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) (Vol-2, Pg. No.9, Item No. 5.4, SR 2021-22)Cum5619.65619.619.31FalseNoneNoneFalseNoneFalse108514.4760
241307172223None9.2Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per direction of Engineer incharge. (Vol-2, Pg. No.59, Item No.9.2, SR 2021-22)Sqm740.25740.25192.0FalseNoneNoneFalseNoneFalse142128.00
241307372223None1.7Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 110mm dia., 6 kg/sqcm & class 3 (Vol-5, Pg. No. 134, Item No. 1.7 SR 2021-22)m413.7413.748.0FalseNoneNoneFalseNoneFalse19857.60
17069400410000NoneNoneOther WorksChain Link Fencing7831809.89
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
241307972224Volume -1-Common SR- Chapter - I- Earth Work1.14.1In all kinds of soils Depth upto 3 mCum73.076.65321.63FalseNoneNoneFalseNoneFalse24652.93950
241308172224Volume-2-For Buildings Chapter-11-Steel and Aluminium Work11.57.2Supplying at site Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. etc. complete.kg96.0100.826868.6FalseNoneNoneFalseNoneFalse2708354.880
241308372224Volume-2-For Buildings Chapter-11-Steel and Aluminium Work11.59Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. (Made of G.I. wire of dia. 4 mm, PVC coated to achieve outer dia not less than 5 mm in required colour and shade)Sqm715.0750.752580.0FalseNoneNoneFalseNoneFalse1936935.00
241308672224Volume-2-For Buildings Chapter-8-Finishing8.41Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm130.0136.52580.0FalseNoneNoneFalseNoneFalse352170.00
241308772224Volume-2-For Buildings Chapter-11-Steel and Aluminium Work11.25.2Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.kg108.0113.4300.0FalseNoneNoneFalseNoneFalse34020.00
241308972224Volume-3-For Roads And Bridges - Chapter-8-Traffic Signs, Markings And Other Appurtenances8.8Direction and Place Identification Signs with size more than 0.9 Sqm size Board. Providing and erecting direction and place identification retro- reflectorised sign as per IRC:67:2012 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick or Aluminium composite material sheet with overall thickness of 4mm with area exceeding 0.9 Sqm fixed over back support frame of min 40 x 40 x 5mm angle mounted on a mild steel circular pipe 65 NB, firmly fixed to the ground by means of properly designed foundation with Sqm5 grade cement concrete 45 x 45 x 60 cm, 60 cm below ground level as per approved drawingSqm8656.09088.810.0FalseNoneNoneFalseNoneFalse90888.00
241308072224NoneA130AProviding and Filling in foundation with granite / trap broken metal 100mm and down size with approved M-Sand including hand packing, ramming, watering including cost of all materials and labour with all lead and lift complete as per specifications. (Pg. No. 64 SOR Code A130A SR 2021-22 V- 5)Cum1672.651672.65131.61FalseNoneNoneFalseNoneFalse220137.46650
241308272224None2.1.2Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8 (M10) Using 40 mm nominal size graded crushed coarse aggregates. (Vol-1, Pg. No.15, Item No. 2.1.2, SR 2021-22)Cum5466.35466.387.74FalseNoneNoneFalseNoneFalse479613.1620
241308472224None5.4Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) (Vol-2, Pg. No.9, Item No. 5.4, SR 2021-22)Cum5619.65619.6215.51FalseNoneNoneFalseNoneFalse1211079.9960
241308572224None2.1.4Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates. (Vol-1, Pg. No.15, Item No. 2.1.4, SR 2021-22)Cum6014.46014.4102.8FalseNoneNoneFalseNoneFalse618280.320
241308872224None8.17.1Providing Flush / Ruled/ Struck or weathered pointing Pointing on brick work or brick flooring with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer in-charge. (Vol-2, Pg. No.44, Item No. 8.17.1, SR 2021-22)Sqm142.8142.8957.83FalseNoneNoneFalseNoneFalse136778.1240
241309072224NoneMoRTH 804Providing and fixing board displaying information, such as 'Name of work, Tender cost, Name of Contractor, Work completion and liability period etc', having rectangular shape of 1.20m x 0.90m size made out 18 gauge (1.25mm) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stove enamel on back side and border / messages / symbols etc. with approved colour shade paint complete, on M.S.angle of size 35 x 35 x 3 mm frame with properly cross braced M.S. angles of size 35mmx35mmx3mm duly painted including Two M.S. angle iron posts of size 65 mm x 65 mm x 6 mm, 3.65 m long painted with alternate black and white bands of 25 cm width including all fixtures etc.and fixing the boards in 1:4:8 concrete block of size 60 cm x 60 cm x 75 cm including, excavation, refilling, transportation, and labour etc complete. Spec. No. As directed by Engineer in Charge & MoRTH specification 804 (Vol-3, Pg. No.151, Item No.4 MoRTH 804, SR 2021-22)Nos9450.09450.02.0FalseNoneNoneFalseNoneFalse18900.00
17069400410000NoneNoneOther WorksAsphalt Road7023749.8
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
241309172225Volume-3-For Roads And Bridges - Chapter-3- Earthwork, Erosion Control and Drainage3.7Compacting Original Ground Compacting original ground supporting embankment Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction.Cum87.091.351260.0FalseNoneNoneFalseNoneFalse115101.00
241309372225Volume -1-Common SR- Chapter - I- Earth Work1.8Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.Cum402.0422.11260.0FalseNoneNoneFalseNoneFalse531846.00
241309572225Volume-3-For Roads And Bridges - Chapter-3- Earthwork, Erosion Control and Drainage3.6Construction of Subgrade and Earthen Shoulders Construction of sub-grade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2Cum413.0433.65665.04FalseNoneNoneFalseNoneFalse288394.5960
241309772225Volume-3-For Roads And Bridges - Chapter-4 - Sub-Bases, Bases (Non-Bituminous) and Shoulders 4.2.B.vFor Grading -V MaterialCum2234.02345.71260.0FalseNoneNoneFalseNoneFalse2955582.00
241309972225Volume-3-For Roads And Bridges - Chapter-4 - Sub-Bases, Bases (Non-Bituminous) and Shoulders 4.23.A.ii.bUsing Screening Type B (11.2mm agg)Cum2519.02644.95351.0FalseNoneNoneFalseNoneFalse928377.450
241310072225Volume-3-For Roads And Bridges - Chapter-4 - Sub-Bases, Bases (Non-Bituminous) and Shoulders 4.27.AWet Mix Macadam (Plant mix method) Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density.Cum2394.02513.7337.5FalseNoneNoneFalseNoneFalse848373.750
241309272225None5.2, B(i)Providing and applying primer coat with SS1 grade Bituminous Emulsion on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.90 kg/m2 using mechanical means. B-Prime Coat over Stabilised soil base / Crusher Run Macadam (Vol-3, Pg. No.29, Item No.5.2, B(i), SR 2021-22)Sqm55.6555.654500.0FalseNoneNoneFalseNoneFalse250425.00
241309472225None5.4(ii)Providing and applying tack coat with RS1 Bituminous Emulsion using emulsion pressure distributor at the rate of 0.25 kg/m2 on the prepared bituminous surface cleaned with mechanical broom. Tack coat on Granular surface treated with primer (Vol-3, Pg. No.29, Item No.5.4(ii), SR 2021-22)Sqm14.714.74500.0FalseNoneNoneFalseNoneFalse66150.00
241309672225None5.19Providing, laying and rolling of open - graded premix surfacing of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using viscosity grade bitumen VG-30 to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable Hot mix plant of capacity not less than 40/60 TPH laying and rolling with a smooth wheeled roller, finished to required level and grades. Open - Graded Premix Surfacing (Vol-3, Pg. No.37, Item No.5.19, SR 2021-22)Sqm150.15150.154500.0FalseNoneNoneFalseNoneFalse675675.00
241309872225None5.21 (i)Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A and B seal coats with bituminous binder VG-30. Seal Coat, (i) Case - I : Type A Premix Sand Seal coat. (Vol-3, Pg. No.37, Item No.5.21 (i), SR 2021-22)Sqm80.8580.854500.0FalseNoneNoneFalseNoneFalse363825.00
17069400410000NoneNoneOther WorksDrain10409749.13
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
241310172226Volume -1-Common SR- Chapter - I- Earth Work1.14.1In all kinds of soils Depth upto 3 mCum73.076.653622.6FalseNoneNoneFalseNoneFalse277672.290
241310372226Volume -1-Common SR- Chapter - I- Earth Work1.1Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications Cum122.0128.1507.6FalseNoneNoneFalseNoneFalse65023.560
241310272226NoneA130AProviding and Filling in foundation with granite / trap broken metal 100mm and down size with approved M-Sand including hand packing, ramming, watering including cost of all materials and labour with all lead and lift complete as per specifications. (Pg. No. 64 SOR Code A130A SR 2021-22 V- 5)Cum1672.651672.65538.4FalseNoneNoneFalseNoneFalse900554.760
241310472226None2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates. (Vol-1, Pg. No.15, Item No. 2.1.3, SR 2021-22)Cum5831.75831.7269.2FalseNoneNoneFalseNoneFalse1569893.640
241310572226None9.3Supplying, Fitting and Placing TMT Fe 550 & above Reinforcement in Foundation / Substructure / Superstructure complete as per Drawing and Technical Specifications. (Vol-3, Pg. No.71, Item No. 9.3, SR 2021-22)MT84311.8584311.8531.75FalseNoneNoneFalseNoneFalse2676901.23750
241310672226None2.4.2Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications, M20 Design Mix using 20mm nominal size graded crushed coarse agregate, Additionalities for Formwork, Centering & Scaffolding cement concrete drain 35% (The cost of steel reinforcement & formwork to be paid separately) (Vol-1, Pg. No.119, Item No. 2, SR 2021-22)Cum8459.648459.64581.55FalseNoneNoneFalseNoneFalse4919703.6420
17069400410001NoneNoneOther WorksCulvert690650.83
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
241310772227Volume -1-Common SR- Chapter - I- Earth Work1.14.1In all kinds of soils Depth upto 3 mCum73.076.6566.26FalseNoneNoneFalseNoneFalse5078.8290
241311072227Volume-2-For Buildings Chapter-9-Flooring9.4Providing and laying Cement concrete pavement with 1:2:4 for commercial & residential building floors, hardpaths, footpaths using 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size, including finishing complete as per Engineer incharge.Cum6200.06510.00.41FalseNoneNoneFalseNoneFalse2669.10
241310872227NoneA130AProviding and Filling in foundation with granite / trap broken metal 100mm and down size with approved M-Sand including hand packing, ramming, watering including cost of all materials and labour with all lead and lift complete as per specifications. (Pg. No. 64 SOR Code A130A SR 2021-22 V- 5)Cum1672.651672.658.55FalseNoneNoneFalseNoneFalse14301.15750
241310972227None2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates. (Vol-1, Pg. No.15, Item No. 2.1.3, SR 2021-22)Cum5831.75831.76.41FalseNoneNoneFalseNoneFalse37381.1970
241311172227None9.3Supplying, Fitting and Placing TMT Fe 550 & above Reinforcement in Foundation / Substructure / Superstructure complete as per Drawing and Technical Specifications. (Vol-3, Pg. No.71, Item No. 9.3, SR 2021-22)MT84311.8584311.853.05FalseNoneNoneFalseNoneFalse257151.14250
241311272227None2.4.2Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications, M20 Design Mix using 20mm nominal size graded crushed coarse agregate. Additionalities for Formwork, Centering & Scaffolding, Culverts (Head walls) (The cost of steel reinforcement & formwork to be paid separately) (Vol-1, Pg. No.17, Item No. 2.4.2, SR 2021-22)Cum8459.648459.6442.12FalseNoneNoneFalseNoneFalse356320.03680
241311372227None5.4Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) (Vol-2, Pg. No.9, Item No. 5.4, SR 2021-22Cum5619.65619.62.43FalseNoneNoneFalseNoneFalse13655.6280
241311472227None8.19.2Providing Raised and cut pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge. (Vol-2, Pg. No. 44, Item No. 8.19.2 SR 2021-22)Cum379.05379.0510.8FalseNoneNoneFalseNoneFalse4093.740
17069400410001NoneNoneOther WorksWater Supply17283887.68
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
241311572228Volume -1-Common SR- Chapter - I- Earth Work1.14.1In all kinds of soils Depth upto 3 mCum73.076.654755.5FalseNoneNoneFalseNoneFalse364509.0750
241311772228Volume -1-Common SR- Chapter - I- Earth Work1.8Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.Cum402.0422.11199.0FalseNoneNoneFalseNoneFalse506097.90
241311972228Volume-2-For Buildings Chapter-13-Water Suppy & Drainage Works13.4.232 mm nominal boreNos.577.0605.85100.0FalseNoneNoneFalseNoneFalse60585.00
241312172228Volume-2-For Buildings Chapter-13-Water Suppy & Drainage Works13.4.450 mm nominal boreNos.834.0875.7100.0FalseNoneNoneFalseNoneFalse87570.00
241311672228NoneA130AProviding and Filling in foundation with granite / trap broken metal 100mm and down size with approved M-Sand including hand packing, ramming, watering including cost of all materials and labour with all lead and lift complete as per specifications. (Pg. No. 64 SOR Code A130A SR 2021-22 V- 5)Cum1672.651672.65275.0FalseNoneNoneFalseNoneFalse459978.750
241311872228None2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates. (Vol-1, Pg. No.15, Item No. 2.1.3, SR 2021-22)Cum5831.75831.7347.5FalseNoneNoneFalseNoneFalse2026515.750
241312072228None9.3Supplying, Fitting and Placing TMT Fe 550 & above Reinforcement in Foundation / Substructure / Superstructure complete as per Drawing and Technical Specifications. (Vol-3, Pg. No.71, Item No. 9.3, SR 2021-22)MT84311.8584311.8528.63FalseNoneNoneFalseNoneFalse2413848.26550
241312272228None2.4.2Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications, M20 Design Mix using 20mm nominal size graded crushed coarse agregate. Appendix I Add formwork of 35% for finished rate of concrete (Vol-1, Pg. No.119, Item No. 9, SR 2021-22) (The cost of steel reinforcement & formwork to be paid separately) (Vol-1, Pg. No.17, Item No. 2.4.2, SR 2021-22)Cum8459.648459.64783.5FalseNoneNoneFalseNoneFalse6628127.940
241312372228None3.7Supplying S&S RCC SPUN / VIBRATED CAST PIPES (REINFORCED) pipes NP-3 Class conforming to IS:458-1988 with latest amentments using ordinary portland cement, for sanitary works and conveying to work site, rolling and lowering into trenches, laying true to line and level including loading and unloading at both destinations and jointing of pipes and specials, perfect linking of joints with jack to correct position including cost of jointing materials, i.e, rubber rings conforming to IS: 5382 for S&S RCC pipes, with all leads and lifts as directed and giving necessary hydraulic test as per ISS to the required pressure and commissioning etc. complete. (Contractor will make his own arrangements for procuring water for testing). Before the execution of the work, the contractor shall carry out the survey. RCC NP3 Class pipe of 600 mm dia. (Vol-5 Sl.No.3.7, P.No.185 /2021-22)m2882.252882.251400.0FalseNoneNoneFalseNoneFalse4035150.00
241312472228None2.9Providing, Laying and Fixing GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For Medium Duty GI pipe of 100mm dia (Vol-5 lt.No.2.9 P.No.142/2021-22)Mtr1079.41079.4200.0FalseNoneNoneFalseNoneFalse215880.00
241312572228None2.6Providing, Laying and Fixing GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For Medium Duty GI pipe of 50mm dia (Vol-5 lt.No.2.6 P.No.142/2021-22)Mtr502.95502.95150.0FalseNoneNoneFalseNoneFalse75442.50
241312672228None1.3 Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:PVC pipes 50mm dia., 6 kg/sqcm & class 3. (Vol-5 lt.No.1.3 P.No.134 /2021-22)Mtr100.8100.8150.0FalseNoneNoneFalseNoneFalse15120.00
241312772228None1.5Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:PVC pipes 75 mm dia., 6 kg/sqcm & class 3. (Vol-5 lt.No.1.5 P.No.134 /2021-22)Mtr220.5220.5200.0FalseNoneNoneFalseNoneFalse44100.00
241312872228None1.7Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:PVC pipes 110mm dia., 6 kg/sqcm & class 3. (Vol-5 lt.No.1.7 P.No.134 /2021-22)Mtr413.7413.7225.0FalseNoneNoneFalseNoneFalse93082.50
241312972228None1.9Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:PVC pipes 160mm dia., 6 kg/sqcm & class 3. (Vol-5 lt.No.1.9 P.No.134 /2021-22)Mtr628.95628.95200.0FalseNoneNoneFalseNoneFalse125790.00
241313072228None1.1Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc.Note: Upto 110mm dia Coil shall be used. For Grade PE80 PN6.0 : HDPE Grade PE80-PN6.0, 63mm dia (Vol-5 lt.No.1.1 P.No.121 /2021-22)Mtr150.15150.15200.0FalseNoneNoneFalseNoneFalse30030.00
241313172228None1.2Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc.Note: Upto 110mm dia Coil shall be used. For Grade PE80 PN6.0 : HDPE Grade PE80-PN6.0, 75mm dia (Vol-5 lt.No.1.2 P.No.121 /2021-22)Mtr193.2193.2150.0FalseNoneNoneFalseNoneFalse28980.00
241313272228None1.4Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc.Note: Upto 110mm dia Coil shall be used. For Grade PE80 PN6.0 : HDPE Grade PE80-PN6.0,110mm dia (Vol-5 lt.No.1.4 P.No.121 /2021-22)Mtr365.4365.4200.0FalseNoneNoneFalseNoneFalse73080.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17069400400000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17069400400000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17069400400000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17069400400000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17069400400000NoneNoneELIGIBILITYThe bidder is required to ensure browser compatibility of the computer well in advance to the last date and time for receipt of tenders. The departments shall not be responsible for non-accessibility of e-Procurement portal due to internet connectivity issues and technical glitches at bidders end.None
17069400400000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17069400400000NoneNoneELIGIBILITYBidder shall pay Contract Management Module processing fees of 0.025% of the contact value (Min Rs.500/- & Max Rs.7500/-) soon after contract has been issued to bidder.None
17069400400000NoneNoneELIGIBILITYThe conditional Tender will not be accepted.None
17069400400000NoneNoneELIGIBILITYThe tenderer shall bear all costs associated with the preparation and submission of his tender, and the employer will in no case be responsible and liable for those costs.None
17069400400000NoneNoneELIGIBILITYRoyalty on construction materials and other taxes will be deducted as per prevailing Govt orders.None
17069400400000NoneNoneELIGIBILITYAs per Karnataka state Government order LD/300/LET/2006 Bangalore dated 01.01.2007 and Government letter no PW/134/BMS/2007 dated 27.07.2007, a sum amounting to 1% of the bill amount will be deducted towards constructions labour welfare fund.None
17069400400000NoneNoneELIGIBILITYAll the formats prescribed in the bid document shall be filled by the tenderer in complete manner.None
17069400400000NoneNoneELIGIBILITYThe employer reserves the rights to Reject or accept any or all the tenders without assigning any reasons.None
17069400400000NoneNoneELIGIBILITYIn the case of the death of the contractor after executing the agreement / commencement of the work, his legal heir, if is an eligible registered contractor and is willing can execute and compete the work at the accepted tender rates irrespective of the cost of the work.None
17069400400000NoneNoneELIGIBILITYThe successful Tenderer shall deliver to the Employer a Security deposit in any of the forms given for an amount equivalent to 5% of the Contract price plus additional security for unbalanced tenders in accordance with the Conditions of Contract.None
17069400400000NoneNoneELIGIBILITYContractor should carryout additional test required to test the suitability of materials.None
17069400400000NoneNoneELIGIBILITYAll safety precautions, warning signs, night illumination, reflectors, deployment of security guards has to be ensured so that no untoward incident happens on account of negligence or any project activity. Contractor should indemnify the client to that extent.None
17069400400000NoneNoneELIGIBILITYAll the items in the tender include all lead, lifts, loading unloading, transportation, labour, hire charges of machinery curing for concrete works, cost and conveyance of all material and all other such incidental charges necessary for successful completion of works as per the detailed technical specification and direction of Engineer- in-charge of this work.None
17069400400000NoneNoneELIGIBILITYContractor should follow strictly the prevailing rules of labour act.None
17069400400000NoneNoneELIGIBILITYContractor should take all precautions to ensure that no damage is caused to the existing structures which have been constructed by other agencies during project execution. If any damage is caused, it has to be rectified at his own risk and cost.None
17069400400000NoneNoneELIGIBILITYThe cost of the Tender processing fees shall not be refundable.None
17069400400000NoneNoneELIGIBILITYFurther particulars, if any, required by the Contractor can be had from the office of the Executive Engineer, during office hours on all working days.None
17069400400000NoneNoneELIGIBILITYMaterials like steel, cement etc., required for the work shall be procured by the tenderer themselves and should get tested by the quality control authority before use on the work at their own cost. Department will not supply any materials.None
17069400400000NoneNoneELIGIBILITYThe contractors assessed available tender capacity will be calculated as per the clause 3.6 of kw-4 tender document Attached.None
17069400400000NoneNoneELIGIBILITYFormation levels and other data furnished are bare minimum the contractor should make all efforts to validate and to get additional data if required at his own cost.None
17069400400000NoneNoneELIGIBILITYAll precautions should be taken by the contractor so that there are no damages to such public/ private properties. Also the Contractor should take all precautionary measures to avoid any damage to the utilities during excavation as well as utility shifting. To that extent the contractor should indemnify the client.None
17069400400000NoneNoneELIGIBILITYThe tenderer should submit proposed methodology and program of construction backed with equipment and material planning, & deployment duly supported with broad calculation and quality management , plan, proposed to be adopted justifying their capability of execution and completion of the work as per technical specifications and within the stipulated period of completion.None
17069400400000NoneNoneELIGIBILITYThe intending contractors are requested to note that they should abide by the detailed instructions and conditions contained in the Standard Tender documents KW-4 K.P.W.D. and further orders there on.None
17069400400000NoneNoneELIGIBILITYContractors should be registered with KPWD/CPWD/Port Trust and e-procurement registered Contractor.None
17069400400000NoneNoneELIGIBILITYAll scanned documents to be uploaded shall be in original and the same originals should be produced to the Executive Engineer (at the time of Technical Bid Opening) who reserves the right to verify the documents before approval.None
17069400400000NoneNoneELIGIBILITYWork shall be executed as per standard specifications.None
17069400400000NoneNoneELIGIBILITYBidder should have valid Registration with Employees Provident Fund Organization under EPF and Miscellaneous Provisions Act, 1952. (Should Attach Latest Copies)None
17069400400000NoneNoneELIGIBILITYWork Done Certificates issued by not below the rank of Executive EngineerNone
17069400400000NoneNoneELIGIBILITYGoods and Service Tax (GST), The contractor shall be allowed to bill GST complying with GST rules at prevailing rate in running account bill and for reimbursement by the Employer, Tax invoice is required to be submitted and Information in GST should appear/display.None
17069400400000NoneNoneELIGIBILITYGST will be paid separately as per Government Oder.None
17069400400000NoneNoneELIGIBILITYThe Increase in GST shall not be paid in the extended period of contract for which the contractor alone is responsible for delays as determined by the authority while granting the extension of time.None
17069400400000NoneNoneELIGIBILITYThe Tenderer shall obtain the work done certificate in the prescribed format from the Competent Authority not below the rank of Executive Engineer (District Level Officer) and scan the Original Certificate and attach the scanned file to the Bid. The Original Certificate/Certificates shall be produced at the time of opening of technical Bids for physical verificationNone
17069400400000NoneNoneELIGIBILITYThe Tenderer shall scan the Original Ownership Documents/ Lease/ Hire commitment Agreement for the Machinery, Bank Guarantee and attach the scanned file to the Bid. The Original Documents shall be produced at the time of opening of technical Bids for physical verificationNone
17069400400000NoneNoneELIGIBILITYBidders should quote the rate exclusive of GST only and GST Declaration Certificate Duly signed by contractor should upload in the portalNone
17069400400000NoneNoneELIGIBILITYThe period for completion of the work is 18 months.None
17069400400000NoneNoneELIGIBILITYThe defect liability period is 365 daysNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneContractors should be registered with KPWD/CPWD/Port Trust and e-procurement registered Contractor.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneSatisfactorily completed (at least 90% of the Contract Value), as prime contractor, at least One similar work such as Construction/Development of Fish Pond Work of value not less than Rs.531.01 lakhs (Usually not less than 50% of estimated value of contract)Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Work Done Certificates issued by not below the rank of Executive Engineer
NoneNoneNoneNoneExecuted in any one year in the last five years, the following minimum quantities of work- RCC/PCC 3598.00 Cum TMT Steel 130.58 MT Embankment/ Filling 5108.14 Cum GSB 1092.00Cum WBM 304.20CumPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Work Done Certificates issued by not below the rank of Executive Engineer
NoneNoneNoneNoneTenderers who meet the above specified minimum qualifying criteria, will only be qualified, if their available tender capacity is more than the total tender value. The available tender capacity will be calculated as under: Assessed available tender capacity -(AxNx1.5-B) Where, A-Maximum value of civil engineering works executed in any one year during the last five years (updated to 2023-24 price level) taking into account the completed as well as works in progress. N- Number of years prescribed for completion of the works for which tenders are invited 1.50 year (18 Months) B-Value, at 2023-24 price level, of existing commitments and on-going works to be completed during the next 1.50 year (18 Months) (period of completion of the works for which Tenders are invited)Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- EXISTING & ON-GOING WORK DETIALS
NoneNoneNoneNoneBidder should have valid Registration with Employees Provident Fund Organization under EPF and Miscellaneous Provisions Act, 1952. (Should Attach Latest Copies)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneValid ESI certificate
NoneNoneNoneNoneSite Labs : Contractor should establish their own Laboratory with qualified personnel.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Site Labs : Contractor should establish their own Laboratory with qualified personnel.
NoneNoneNoneNoneEach Tenderer should further demonstrate:(a)Availability by owning at least 50% of required / specified key and initial equipment for this work Excavators 4 No.s (2 own & 2 hire)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Certificate copy of RC with Ownership, hire deed or purchase invoice with Latest Insurance copies
NoneNoneNoneNoneConcrete Self Loader 4 No.s (2 own & 2 hire)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Certificate copy of RC with Ownership, hire deed or purchase invoice with Latest Insurance copies
NoneNoneNoneNoneTippers 6 No.s (3 own & 3 hire)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Certificate copy of RC with Ownership, hire deed or purchase invoice with Latest Insurance copies
NoneNoneNoneNoneVibratory Road Roller 1 No (1 own/hire)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Certificate copy of RC with Ownership, hire deed or purchase invoice with Latest Insurance copies
NoneNoneNoneNoneTo qualify for award of this contract, each Tenderer in its name should have in the last five years i.e. 2018-19 to 2022-23)(a) achieved in at least two financial years a minimum financial turnover (in all classes of civil Engineering construction works only) of Rs.1416.03 lakhs (Usually not less than two times the estimated annual payments under this contract)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneliquid assets and /or availability of credit facilities of not less than Rs.177.00 Lakhs (Credit lines/ letter of credit/ certificates from banks for meeting the fund requirement etc. (usually the equivalent of the estimated cash flow for three months in the peak construction period).Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Certificate issued by Nationalized or Scheduled Bank - in prescribed format
NoneNoneNoneNoneThe EMD of Rs.15,00,000/- shall be paid through e- payment OR in two parts Part- I Rs.1,00,000/-through e-payment & Part-II remaining Rs.14,00,000/-in the form of Bank Guarantee issued by any Nationalized / Scheduled bank. The tenderer should upload the scanned copy of the original Part-2 of the EMD in e portal.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Certificate issued by Nationalized or Scheduled Bank
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Registration CertificateTrueTechnical Bid
ESI & PF Registration CopyTrueTechnical Bid
Turnover Details -P&L, Balance sheet, IT returns filed details filed copyTrueTechnical Bid
Certificate copy of RC with Ownership, hire deed or purchase invoice with Latest Insurance copiesTrueTechnical Bid
LOC/Banker Certificate - In prescribed format onlyTrueTechnical Bid
EMD document other than E-paymentTrueTechnical Bid
Work done Certificate / EXISTING & ON-GOING WORK DETIALSTrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1706940762000
version0
createdDateNone
modifiedDateNone
blockNumberOffice of the Executive Engineer Port and Fisheries Division
streetNone
cityUdupi
stateKarnataka
pin576103
tenderRecallDTONone