tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1707045628000 | 0 | None | None | Buildings | Providing & Installation of RO plant and water supply arrangements | 818064.45 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2430978 | 73092 | None | BGM01 | Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete. (internal work exposed on wall) - 50mm nominal OD pipes as per corigendam (CSR 2023-24/Vol No. 2/P122/I 13.31.6) | Mtr | 820.05 | 820.05 | 150.0 | False | None | None | False | None | False | 123007.5 | 0 | 2430979 | 73092 | None | BGM02 | Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete. (internal work exposed on wall) - 25 mm nominal OD pipes as per corigendam (CSR 2023-24/Vol No. 2/P 122/I 13.31.3) | Mtr | 333.9 | 333.9 | 100.0 | False | None | None | False | None | False | 33390.0 | 0 | 2430980 | 73092 | None | BGM03 | Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark , For 50 mm dia GM (Copper alloy) Gate valves (CSR 2023-24/Vol-V / P-133/11.15.6) | Nos | 1772.4 | 1772.4 | 4.0 | False | None | None | False | None | False | 7089.6 | 0 | 2430981 | 73092 | None | BGM04 | Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark ,For 25 mm dia GM (Copper alloy) Gate valves (CSR 2023-24/Vol-V / P-133/11.15.3) | Nos | 1227.45 | 1227.45 | 6.0 | False | None | None | False | None | False | 7364.7 | 0 | 2430982 | 73092 | None | BGM05 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc.complete. Hot finished seamless type tubes including cost of materials,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.( CSR 2023-24- Vol-II (82/11.16.2) | Kg | 154.35 | 154.35 | 700.0 | False | None | None | False | None | False | 108045.0 | 0 | 2430983 | 73092 | None | BGM06 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal,complete upto any pitch in horizontal/ vertical or curved surfaces,excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (CSR 2023-24- Vol-II (P-26/7.38) | Sqm | 596.4 | 596.4 | 12.25 | False | None | None | False | None | False | 7305.9 | 0 | 2430984 | 73092 | None | BGM07 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-incharge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications. (CSR 2023-24/Vol No. 2 P 88/11.35.2.2) | Kg | 599.55 | 599.55 | 255.0 | False | None | None | False | None | False | 152885.25 | 0 | 2430985 | 73092 | None | BGM08 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/ sqm) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. . (CSR 2023-24/Vol No. 2 P 89/11.37.1) | Sqm | 1037.4 | 1037.4 | 18.0 | False | None | None | False | None | False | 18673.2 | 0 | 2430986 | 73092 | None | BGM09 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer- incharge: Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side including cost of materials, labour, usage charges of machinery complete as per specifications. (CSR 2023-24/Vol No. 2/P 89 /11.36.1) | Sqm | 941.85 | 941.85 | 18.0 | False | None | None | False | None | False | 16953.3 | 0 | 2430987 | 73092 | None | BGM10 | Water purification plants: Supplying, Installation and Commissioning of automatic Water purification plant RO+UF) with all accessories piping, product water tank on single phase power supply as per the enclosed detailed Technical Specifications including cost of material, loading and unloading and as directed by the Engineer in charge. (Ref- detailed specification enclosed seperatly). Note:- 1.The above rates mentioned are only for the preparation of estimate purpose. 2. All items are to be of BSI /NFS standards,with BSI / NFS mark . 3. Tenders to be invited for procurement. 4. No direct payment should be made under any situation or condition or on any account. 5. After commissioning of plant necessary testing to be done for the satisfactory of Engineer Incharge. Note : Refer the ANNEXURE : F for Detailed Specification of Each components. For 500 LPH SS : Skid Type (CSR 2023-24/ Vol-V / P-247/21.1.7) | Nos | 343350.0 | 343350.0 | 1.0 | False | None | None | False | None | False | 343350.0 | 0 |
| 1707045628000 | 0 | None | None | Buildings | Providing seating arrangements (3 seater MS chairs) | 330000.0 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2430988 | 73093 | None | BGM01 | Providing and fixing MS chairs of 3 seater of approved quality including fixing in flooring, drilling to the suitable holes, groutings complete as per specification and direction of engineer in charge of work complete as per specification with all lead and lift 3 seater chairs. (Aproved Rate of New Bus Station Belagavi) | Nos | 6000.0 | 6000.0 | 55.0 | False | None | None | False | None | False | 330000.0 | 0 |
| 1707045628000 | 0 | None | None | Buildings | Providing & fixing platform boards | 175770.0 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2430989 | 73094 | None | BGM01 | Providing and Fixing Aluminium sheeting 2mm thick or Aluminium composite material ACM sheeting - 3MM Thick fixed with Micro Prismatic (HIP) Type IV sheeting including 2% towards cost of drilling holes, nuts,bolts etc.and signs as applicable (lettering included)(SR 2023-24/Vol-3 // P/ A -9/007) | Sqm | 4882.5 | 4882.5 | 36.0 | False | None | None | False | None | False | 175770.0 | 0 |
| 1707045628000 | 0 | None | None | Buildings | Providing & fixing Aluminium partitions | 555964.5 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2430990 | 73095 | None | BGM01 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-incharge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications. (CSR 2023-24/Vol No. 2 /P 88/11.35.2.2) | Kg | 599.55 | 599.55 | 650.0 | False | None | None | False | None | False | 389707.5 | 0 | 2430991 | 73095 | None | BGM02 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/ sqm) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. . (CSR 2023-24/Vol No. 2 P 89/11.37.1) | Sqm | 1037.4 | 1037.4 | 84.0 | False | None | None | False | None | False | 87141.6 | 0 | 2430992 | 73095 | None | BGM03 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer- incharge: Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side including cost of materials, labour, usage charges of machinery complete as per specifications. (CSR 2023-24/Vol No. 2/P 89 /11.36.1) | Sqm | 941.85 | 941.85 | 84.0 | False | None | None | False | None | False | 79115.4 | 0 |
| 1707045628000 | 0 | None | None | Buildings | Providing & fixing Fabricated gate with construction of RCC columns at Depot 2 entrance | 174433.78 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2430993 | 73096 | None | BGM01 | Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.In all kinds of soils Depth upto 1.5 m (PWD 2023-24 CSR Vol.1/ P - 5/ /1.4.1) | Cum | 254.1 | 254.1 | 16.2 | False | None | None | False | None | False | 4116.42 | 0 | 2430994 | 73096 | None | BGM02 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates. (CSR 2023-24/Vol 1/P No. 15 / I no. 2.1.2) | Cum | 5947.2 | 5947.2 | 0.97 | False | None | None | False | None | False | 5768.784 | 0 | 2430995 | 73096 | None | BGM03 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including formwork. ( CSR 2023-24/Vol No. 1/P 16/2.4.3) | Cum | 6985.44 | 6985.44 | 2.25 | False | None | None | False | None | False | 15717.24 | 0 | 2430996 | 73096 | None | BGM04 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including formwork. ( CSR 2023-24/Vol No. 1/P 16/2.4.3) | Cum | 11309.76 | 11309.76 | 0.91 | False | None | None | False | None | False | 10291.8816 | 0 | 2430997 | 73096 | None | BGM05 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. For Outside walls. (CSR 2023-24/Vol No. 2/P 42/ 8.9) | Sqm | 404.25 | 404.25 | 6.72 | False | None | None | False | None | False | 2716.56 | 0 | 2430998 | 73096 | None | BGM06 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. (CSR 2023-24/Vol -1/18/2.11(a)) | Kg | 93.93 | 93.93 | 230.0 | False | None | None | False | None | False | 21603.9 | 0 | 2430999 | 73096 | None | BGM07 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc.complete. Hot finished seamless type tubes including cost of materials,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.( CSR 2023-24- Vol-II (82/11.16.2) | Kg | 154.35 | 154.35 | 740.0 | False | None | None | False | None | False | 114219.0 | 0 |
| 1707045628000 | 0 | None | None | Buildings | Electrical works | 169242.15 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2431000 | 73097 | None | BGM01 | Supplying heavy gauge PVC conduit pipe 19/20mm dia 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. Make:VIP/Avonplast/Finolex. CSR 2023-24, Volume-VI,PART-III ,Utilization, SRP 2 of 105 | Mtr | 72.45 | 72.45 | 300.0 | False | None | None | False | None | False | 21735.0 | 0 | 2431001 | 73097 | None | BGM02 | Supplying heavy gauge PVC conduit pipe 25mm dia 2 mm thick. confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. Make:VIP/Avonplast/Finolex.CSR 2023-24, Volume-VI,PART-III ,Utilization, SRP 2 of 105/1.1.2 | Mtr | 85.05 | 85.05 | 125.0 | False | None | None | False | None | False | 10631.25 | 0 | 2431002 | 73097 | None | BGM03 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010. 1.5 sqmm. Wire make:Finolex/V-Gaurd /Polycab /Anchor FRLS /Havells /KEI/Salzer . CSR 2023-24, Volume-VI,PART-III ,Utilization, SRP 5 of 105/ 2.3.2 | Mtr | 27.3 | 27.3 | 785.0 | False | None | None | False | None | False | 21430.5 | 0 | 2431003 | 73097 | None | BGM04 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010. 2.5 Sqmm Wire.
make:Finolex/V-Gaurd /Polycab/Anchor /Havells /KEI/Salzer .
CSR 2023-24, Volume-VI,PART-III ,Utilization, SRP 5 of 105/ 2.3.3 | Mtr | 44.1 | 44.1 | 1150.0 | False | None | None | False | None | False | 50715.0 | 0 | 2431004 | 73097 | None | BGM05 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010. 4 Sqmm Wire.
make:Finolex/V-Gaurd /Polycab /Anchor/Havells /KEI/Salzer .
CSR 2023-24, Volume-VI,PART-III ,Utilization, SRP 5 of 105/ 2.3.4 | Mtr | 66.15 | 66.15 | 250.0 | False | None | None | False | None | False | 16537.5 | 0 | 2431005 | 73097 | None | BGM06 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 1-3 way. CSR 2023-24, Volume-VI,PART-III ,Utilization, SRP 8 of 105/ 3.4.2 | Each | 166.95 | 166.95 | 25.0 | False | None | None | False | None | False | 4173.75 | 0 | 2431006 | 73097 | None | BGM07 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 4-5 Way . CSR 2023-24, Volume-VI,PART-III ,Utilization, SRP 8 of 105/ 3.4.3 | Each | 185.85 | 185.85 | 25.0 | False | None | None | False | None | False | 4646.25 | 0 | 2431007 | 73097 | None | BGM08 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3 module. Make:Anchor/GM/Cona/Salzer/Lisha. SR 2023-24, Volume-VI,PART-III ,Utilization, SRP 8 of 105/ 3.5.2 | Each | 169.05 | 169.05 | 25.0 | False | None | None | False | None | False | 4226.25 | 0 | 2431008 | 73097 | None | BGM09 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module.
Make: Anchor/GM/Cona/Salzer/Lisha.
CSR 2023-24, Volume-VI,PART-III ,Utilization,
SRP 8 of 105/ 3.5.3 | Each | 183.75 | 183.75 | 25.0 | False | None | None | False | None | False | 4593.75 | 0 | 2431009 | 73097 | None | BGM10 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6 A One way Switch. Make: Anchor/GM/Cona/Salzer/Lisha.
CSR 2023-24, Volume-VI,PART-III ,Utilization, SRP 9 of 105/ 3.6.1 | Each | 107.1 | 107.1 | 50.0 | False | None | None | False | None | False | 5355.0 | 0 | 2431010 | 73097 | None | BGM11 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6 A Three Way Socket. Make: Anchor/GM/Cona/Salzer/Lisha.
CSR 2023-24, Volume-VI,PART-III ,Utilization, SRP 9 of 105/ 3.6.3 | Each | 179.55 | 179.55 | 50.0 | False | None | None | False | None | False | 8977.5 | 0 | 2431011 | 73097 | None | BGM12 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. I- Single door. 8 Way SP & N. Make: L&T/Sneider /Legrand / Havells.
CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 18 of 105, 5.19.3 | Each | 1367.1 | 1367.1 | 2.0 | False | None | None | False | None | False | 2734.2 | 0 | 2431012 | 73097 | None | BGM13 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6 - 32 Amps SP . Make: L&T/Sneider/Legrand/ Havells. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 17 of 105, 5.18.1 | Each | 549.15 | 549.15 | 6.0 | False | None | None | False | None | False | 3294.9 | 0 | 2431013 | 73097 | None | BGM14 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A DP MCB.
CSR 2023-24, Volume-6, Part-III ,Utilization,
SRP 17 of 105, 5.18.4 | Each | 1158.15 | 1158.15 | 2.0 | False | None | None | False | None | False | 2316.3 | 0 | 2431014 | 73097 | None | BGM15 | Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia.Water Supply & UGD Works CSR 2023-24, Volume-V. SRP 157/13.39 | Job | 3937.5 | 3937.5 | 2.0 | False | None | None | False | None | False | 7875.0 | 0 |
|
|
---|