createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1706945214628
version4
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee500.00
emd25000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose12-02-2024 16:00:00
tenderQueryClose05-02-2024 16:00:00
technicalBidOpen13-02-2024 16:05:00
publishedDate03-02-2024 17:59:56
publishedByPostTP_CO_BLG
publishedByUserKPE15339 - DEVENDRA P DHANPAL
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonB D Koti
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08425275261
mobileNumberNone
tenderSupplierListNone
tenderSchedule
createdTs1706945214654
version6
createdDateNone
modifiedDateNone
tenderNumberDMA/2023-24/OW/WORK_INDENT13852
titleCONSTRUCTION OF ASPIRATIONAL (HITECH) PUBLIC TOILET TAHASHILDRA OFFICE GROUND IN BILAGI TP
descriptionCONSTRUCTION OF ASPIRATIONAL (HITECH) PUBLIC TOILET TAHASHILDRA OFFICE GROUND IN BILAGI TP
categoryWORKS
categoryTextWorks
ecv1000000.00
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2225
locationNameDMA Town Panchayat Bilagi
provisionalAmount1000000.0
groupOverheadTotal151918.09
fileNumberTPC/BGL/SBM/OW/39/2023-24
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17069452150000NoneNoneOther WorksCONSTRUCTION OF ASPIRATIONAL (HITECH) PUBLIC TOILET TAHASHILDRA OFFICE GROUND IN BILAGI TP848081.91
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
241541072338Nonecode01Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in aradius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In All Types of Soil Depth Upto 3Mtrs PWD SR 2023-24 Page No.08. Item No.1.14.1 V1Cum102.0102.032.65FalseNoneNoneFalseNoneFalse3330.30
241541172338Nonecode02Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates PWD CSR 2023-24 Vol-I , P-15 , I. No- 2.1.4Cum6217.06217.06.26FalseNoneNoneFalseNoneFalse38918.420
241541272338Nonecode03Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. PWD CSR 2023-24 Vol-I , P-15 , I. No- 2.2.1Cum6789.966789.962.59FalseNoneNoneFalseNoneFalse17585.99640
241541372338Nonecode04Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.PWD CSR 2023-24 Vol-I , P-16 , I. No-2.3.1Cum10116.810116.86.1FalseNoneNoneFalseNoneFalse61712.480
241541472338Nonecode05Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.PWD CSR 2023-24 Vol-I , P-16 , I. No- 2.5.1Cum11271.011271.01.24FalseNoneNoneFalseNoneFalse13976.040
241541572338Nonecode06Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. Deduct 5% per m3 if rollers are not used and tamping is done manually PWD SOR 2023-24 vol 1 Page no 7 Itm no 1.8Cum474.0474.011.41FalseNoneNoneFalseNoneFalse5408.340
241541672338Nonecode07Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification PWD CSR 2023-24 Vol-I , P-18 , I. No- 2.11 (a)Tonne89457.089457.01.04FalseNoneNoneFalseNoneFalse93035.280
241541772338Nonecode08Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work PWD CSR 2023-24 Vol-2 , P-13 , I. No- 6.2Cum7978.07978.09.17FalseNoneNoneFalseNoneFalse73158.260
241541872338Nonecode09Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of workPWD CSR 2023-24 Vol2I , P-14 , I. No-68Cum7969.07969.013.05FalseNoneNoneFalseNoneFalse103995.450
241541972338Nonecode10Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in foundations and plinth in Cement mortar 1:3 (1 cement : 3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of workPWD CSR 2023-24 Vol-2 , P-14 , I. No- 6.1Sqm1003.01003.011.04FalseNoneNoneFalseNoneFalse11073.120
241542072338Nonecode11Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonry including rounding off corners wherever required smooth redering,providing and removing scaffolding, ncluding cost of materials, labour, curing complete as per specifications and as per direc tions of Engineer-in-charge.PWD SR 20223-24 / Volumme 2 / I.NO-8.3.2/P.NO-41Sqm333.0333.0170.25FalseNoneNoneFalseNoneFalse56693.250
241542172338Nonecode12Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.PWD CSR 2023-24 Vol-2 , P-16 , I. No- 2.5.1Cum9945.09945.04.18FalseNoneNoneFalseNoneFalse41570.10
241542272338Nonecode13Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.PWD SR 20223-24 / Volumme 2 / I.NO-8.3.2/P.NO-41Sqm323.0323.018.62FalseNoneNoneFalseNoneFalse6014.260
241542372338Nonecode14Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Refer Appendix-I For Formwork, Centering, Scaffolding of painting is 25% (Pg No 115 of Common SR 2021-22) PWD SR 20223-24 / Volumme 2 / I.NO-8.28/P.NO-45Sqm111.25111.25147.89FalseNoneNoneFalseNoneFalse16452.76250
241542472338Nonecode15Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge Refer Appendix-I For Formwork, Centering, Scaffolding of painting is 25% (Pg No 115 of Common SR 2021-22).PWD SR 20223-24 / Volumme 2 / I.NO-8.25/P.NO-45Sqm171.25171.2580.04FalseNoneNoneFalseNoneFalse13706.850
241542572338Nonecode16Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete.PWD CSR 2023-24 Vol-2 , P-60 , I. No- 9.9Sqm1076.01076.027.42FalseNoneNoneFalseNoneFalse29503.920
241542672338Nonecode17roviding and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg/m2, including pointing in white cement mixed with pigment of matching shade complete..PWD CSR 2023-24 Vol-2 , P-71 , I. No- 9.10.14Sqm1106.01106.055.81FalseNoneNoneFalseNoneFalse61725.860
241542772338Nonecode18Providing & fixing factory made PVC Door frame of size 50x47mm witha wall thickness of 5mm, made out of extruded 5mm rigid PVC foamsheet metered cut at corners & jointed 2 No.s of 150mm long bracketsof 15x15mm M.S Square tube, the entire door frame to be reinforced with19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to thewall using M.S. Screws of 65/80mm size complete as per manufacturersspecification & direction of Engineer-in-charge. .PWD CSR vol 02 Page No.104 Item No.12.54m318.0318.035.9FalseNoneNoneFalseNoneFalse11416.20
241542872338Nonecode19Providing & fixing 30mm thick factory made rigid foam Panelled Door Shutters made from M.S. tube of 19 gauge thickness, size 19x19mm for stiles and 15x15mm for top & bottom rails, covered with heat moulded PVC C channel of 5mm thick sheet & 30 x 50mm wide to form stiles & 5mm thick & 75mm wide PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick 20mm wide PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet fitted in the M.S. Frame, Sealed to the stiles & rails with 5x30mm PVC sheet beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75 mm Aluminium hinges.PWD CSR vol 02 Page No.104 Item No.12.53Sqm1588.01588.011.5FalseNoneNoneFalseNoneFalse18262.00
241542972338Nonecode20Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests (PWD SR 2021-22 Vol:2 P.NO. 123 I.No:14.1.1)Each4884.04884.02.0FalseNoneNoneFalseNoneFalse9768.00
241543072338Nonecode21Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid (PWD SR 2021-22 Vol:2 P.NO. 123 I.No:14.2.1)Each4838.04838.02.0FalseNoneNoneFalseNoneFalse9676.00
241543172338Nonecode22Providing & Fixing on terrace on polythene water storage tank marked with cover & suitable locking arrangements (pwd sr 2021-22 1st addedam vol 2 sl/no 12.1 i.no 13.34Ltr9.09.01000.0FalseNoneNoneFalseNoneFalse9000.00
241543272338Nonecode23Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. Page No.86 Item No.11.34B V2 RIR 9/11/22Kg183.0183.017.01FalseNoneNoneFalseNoneFalse3112.830
241543372338Nonecode24Providing & Fixing CPVC Pipes having thermal steability of hot & cold water supply including fixing the pipe clamp @ 1mtr spacing this includes jointing of pipes etc with CPVC Salvent 20mm nominal od pipe PWD SR 2023-24 1st addendum Vol2 sl no 09 ino 13.31.2m242.0242.020.0FalseNoneNoneFalseNoneFalse4840.00
241543472338Nonecode25Providing & Fixing CPVC Pipes having thermal steability of hot & cold water supply including fixing the pipe clamp @ 1mtr spacing this includes jointing of pipes etc with CPVC Salvent 15mm nominal od pipe PWD SR 2023-24 1st addendum Vol2 sl no 09 ino 13.31.1m309.0309.015.0FalseNoneNoneFalseNoneFalse4635.00
241543572338Nonecode26Providing & Fixing brass bib cock of approved quality pwd sr 2021-2 vol 2 pg no 115 i.no 13.21.1m305.0305.05.0FalseNoneNoneFalseNoneFalse1525.00
241543672338Nonecode27Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. pwd sr 2023-24 vol 2 pg no 119 i.no 13.15m3082.03082.02.0FalseNoneNoneFalseNoneFalse6164.00
241543772338Nonecode28Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps PWD SR 2023-24 vol-2 page no-124 I.No-14.7.1m3082.03082.02.0FalseNoneNoneFalseNoneFalse6164.00
241543872338Nonecode29Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.PWD SR 2023-24 Vol-2 page no 127 I.No- 14.28.2 Flexible pipem92.092.02.0FalseNoneNoneFalseNoneFalse184.00
241543972338Nonecode30Supplying PVC ringtite pipes conforming to IS 4985:2000 with latestamendments and conveying to worksite, rolling and lowering intotrenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:PVC pipes 75mm dia., 6 kg/sqcm & class 3 PWD SR 2021-22 Page no-134 I.NO-1.5m370.0370.020.0FalseNoneNoneFalseNoneFalse7400.00
241544072338Nonecode31Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixingCI cover & frame etc. excluding the cost of CI frame and cover. PWD SR 2023-24 Page No.191 Item No.16.9 v5m5454.05454.01.0FalseNoneNoneFalseNoneFalse5454.00
241544172338Nonecode32Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete:15 mm nominal bore (PWD SR 2023-24 Vol:2 P.NO.115 I.No:13.5.1)m296.0296.01.0FalseNoneNoneFalseNoneFalse296.00
241544272338Nonecode33Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.PWD SR 2023-24 Vol:2 P.NO.128 I.No:14.31)m1220.01220.02.0FalseNoneNoneFalseNoneFalse2440.00
241544372338Nonecode34Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA. On wall/ ceiling / Rafter / Girders PWD Electrical SR 2022-23 Page No.45 Item No.13.7.1Each122.0122.01.0FalseNoneNoneFalseNoneFalse122.00
241544472338Nonecode35Supplying of .....feet -PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burninghours & 70% lumen maintenance with CRI 80. PowerInput: 220-240V@ 50/60Hz & Power factor 0.9 along with CEapproved. 2 years Warranty against any manufacturing defectworking under standard electrical condition.LED light fitting 1 x 4' - 20/22 W PWD Electrical SR 2022-23 Page No.34 Item No.11.3.2Each690.0690.05.0FalseNoneNoneFalseNoneFalse3450.00
241544572338Nonecode36Fixing of ..... Amps TPST / change over switch / Contactor along with neutral link with screws, bolts, nuts and wiring using required capacity wires and circuit labeling 15A to 63A TPST (PWD Electrical SR 2022-23 P no 46 I no 13.18.1)Each278.0278.02.0FalseNoneNoneFalseNoneFalse556.00
241544672338Nonecode37Supplying of TPST with rewirable porcelain channels in SM enclosure. Made out of 14 SWG powder coated paint of approved colour. (PWD Electrical SR 2022-23 P no. 10 I no 5.5.2) 63Amps (PWD Electrical SR 2022-23 Page No.02 Item No.1.8.2Each4193.934193.932.0FalseNoneNoneFalseNoneFalse8387.860
241544772338Nonecode38Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box,elbows, screws at an interval of 300 mm .... etc. as required.25mmm35.035.060.0FalseNoneNoneFalseNoneFalse2100.00
241544872338Nonecode39Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. (PWD Electrical SR 2022-23 P No 8 I no 3.3.7) 16-18 WayEach294.0294.02.0FalseNoneNoneFalseNoneFalse588.00
241544972338Nonecode40Supplying and fixing superior quality modular switch mountingpolycarbonate plate with necessary supporting back plate withrequired nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.16-18 Module . (PWD Electrical SR 2022-23 Page No.8 Item No.3.5.8Each457.0457.07.0FalseNoneNoneFalseNoneFalse3199.00
241545072338Nonecode41Wiring for lighting/power circuit using one of FRLS PVCnsulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments 1.5Sqmm (PWD Electrical SR 2022-23 Page No.05 Item No.2.3.2m26.026.060.0FalseNoneNoneFalseNoneFalse1560.00
241545172338Nonecode42Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. (PWD Electrical SR 2022-23 Page No.05 Item No.2.3.4m63.063.060.0FalseNoneNoneFalseNoneFalse3780.00
241545272338Nonecode43Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS1293 and IS 3654 6A 2 Way (PWD Electrical SR 2022-23 Page No.8 Item No.3.1.1Each128.0128.02.0FalseNoneNoneFalseNoneFalse256.00
241545372338Nonecode44Supplying and fixing of modular switch & connected accessorieson existing modular switch plate as per IS 3854 and IS 1293.6A Three Way socket (PWD Electrical SR 2022-23 Page No.9 Item No.3.6.3Each171.0171.02.0FalseNoneNoneFalseNoneFalse342.00
241545472338Nonecode45Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.600w dimmer (PWD Electrical SR 2022-23 Page No.9 Item No.3.6.6Each329.0329.02.0FalseNoneNoneFalseNoneFalse658.00
241545572338Nonecode46Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.50-63 A TPN (PWD Electrical SR 2022-23 Page No.18 Item No.5.18.9Each3088.03088.01.0FalseNoneNoneFalseNoneFalse3088.00
241545672338Nonecode47Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure.6 Way SP & N (PWD Electrical SR 2022-23 Page No.18 Item No.5.19.2Each1186.01186.01.0FalseNoneNoneFalseNoneFalse1186.00
241545772338Nonecode48Supplying and fixing Wiring Earth Electrode For grounding conduits ic cutouts on the meter board using 40mm dia 2.90mm thick GI Pipe 2.50mtr long burried in a pit the pit should be filled up with equal propotion of salt & charcoal 150mm alll around the pipe to complete depth (PWD Electrical SR 2022-23 Page No.54 Item No.12.56Each3510.03510.01.0FalseNoneNoneFalseNoneFalse3510.00
241545872338Nonecode49For Electrical & Hescom ChargesEach8000.08000.01.0FalseNoneNoneFalseNoneFalse8000.00
241545972338Nonecode50Supplying lowering laying, jointing, testing and commissioning of following5 diameters glazed stone ware pipes, conforming to IS 651:1992, (with 5th revision) in all respects jointing with EPDM rubber rings (seals according to EN 681 & ASPM 425) The rubber seals joints pipe will have groves in interior of socket and exterior of the spigot. The rubber gasket shall be prefixed at the factory by the manufacturer rigidly with approved glue to have leak proof joint including conveying of pipe to work site and rolling and lowering into trenches, laying true to line, level and perfect linking at joints testing and commissoning including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of GSW pipes and specials, with rubber gaskets conforming to EN 681 and ASTM C-425 including cleaning the socket and spigot with soap solution and applying talcum powder for detecting crack, then applying glue and before inserting of rubber gaskets, jacking and fixing in perfect condition including the cost of soap solution, talcum powder and glue etc. and giving necessary hydraulic test to the required pressure of water head with all lead and lifts including costing of jointing materials and all necessary surve works for laying of sewers etc., and disposal of debris as directed etc., complete. (Contractor will make his own arrangements for procuring water for testing) with Rubber ring gasket joints 100 mm dia. pipes (This is for house service connection only)(PWD Electrical SR 2022-23 Page No.187 Item No.16.1.1Each370.0370.015.0FalseNoneNoneFalseNoneFalse5550.00
241546072338Nonecode51Porcelain Fuse Channel Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. 32Amps (P.no.10.it.no.5.7.2) (PWD CSR for Electrical Works for the Year 2023-24)No241.0241.02.0FalseNoneNoneFalseNoneFalse482.00
241546172338Nonecode52Providing and fixing PVC (S.W.R) S Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete PWD CSR 2023-24, Vol-II, P. No. 127, I. No. 13.62No358.0358.04.0FalseNoneNoneFalseNoneFalse1432.00
241546272338Nonecode53Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete PWD CSR 2023-24, Vol-II, P. No. 127, I. No. 13.59No120.0120.05.0FalseNoneNoneFalseNoneFalse600.00
241546372338Nonecode54Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. E.R.W. tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.( Vol 2, PageNo. 84 , Item No. 11.26.2)Kg120.0120.0218.2FalseNoneNoneFalseNoneFalse26184.00
241546472338Nonecode55Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size as per direction of Engineer in charge and finished smooth. PWD CSR 2023-24, Vol-II, P. No. 70, I. No. 10.8Sqm2789.02789.02.97FalseNoneNoneFalseNoneFalse8283.330
241546572338Nonecode56Providing and fixing white vitreous china squatting plate urinal with integral rim longitudinal flush pipe. PWD CSR 2023-24, Vol-II, P. No. 135, I. No. 14.24Each2835.02835.02.0FalseNoneNoneFalseNoneFalse5670.00
241546672338Nonecode57Providing & fixing upvc ventilator with Exhaust Turbo speed fan with 5 blades (300mm x 300 mm & above sized fan) with copper motor having mounting arrangements as per direction of Engineer in charge of work PWD CSR 2023-24, Vol-II, P. No. 221 I. No. 22.49Each1950.01950.02.0FalseNoneNoneFalseNoneFalse3900.00
241546772338Nonecode58Hand Dryer ( Market Rates )Each3500.03500.02.0FalseNoneNoneFalseNoneFalse7000.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17069452190000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17069452190000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17069452190000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17069592080000NoneNoneELIGIBILITYConditional tenders are not acceptedNone
17069592160000NoneNoneELIGIBILITYThe employer reserves the rights to Reject or accept any or all the tenders without assigning any reasonsNone
17069592320000NoneNoneELIGIBILITYAll safety precautions, warning signs, night illumination, reflectors, deployment of security guards has to be ensured so that no untoward incidents happens on account of negligence or any project activity. Contractor should indemnify the client to that extentNone
17069592420000NoneNoneELIGIBILITYThe Tenderer should furnish all the necessary original documents mentioned above at the time of evaluation of BidNone
17069592550000NoneNoneELIGIBILITYThe tenderer should maintain the work/Supply during the defective liability period for 2 years after completion of the work.None
17069592640000NoneNoneELIGIBILITYRoyalty on construction materials and other taxes will be deducted as per prevailing Govt Orders.None
17069592800000NoneNoneELIGIBILITYContractors should follow strictly prevailing rules of labour act and a sum of amounting to 1% of the bill amount will be deducted towards construction labour fund as per govt order.None
17069592990000NoneNoneELIGIBILITYThis work should be Inspected by the 3rd party Agency and after getting 3rd party report satisfactory payment will be made.None
17069593690000NoneNoneELIGIBILITYAll scanned documents to be uploaded shall be in original and the Chief officer TP Bilagi reserves the right to verify the documents before approval.None
17069593790000NoneNoneELIGIBILITYThe earnest money deposit may be forfeited if the documents submitted the Tenderer found to misleading/forged or fake.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneSatisfactorily completed as a prime Contractor for at least one similar nature of work to an extent of 50 percent of the cost of the work during last 5 years 2018-19 to 2022-23,work done certificate should be countersigned by a district level officer not below the rank of executive engineerPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneSummary of financial turnover certificate duly certified by CA during last 5 years 2018-19 to 2022-23 (With Valid UDIN Number)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneAdditional performance Security (Below DD) for Unbalanced Tenders in the Form of DD/FDR/BC from Nationalized Or Scheduled Bank should be scanned and uploadFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Additional performance Security Below DD
NoneNoneNoneNoneValid Contractor Registration CertificateOthersValid Contractor Registration Certificate
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneContractor Name and Details address, Email Id Or Whatsapp mobile no.OthersContractor Name and Details address, Email Id Or Whatsapp mobile no.
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Contractor Name and Details address, Email Id Or Whatsapp mobile no.
NoneNoneNoneNoneValid Contractor Registration CertificateOthersValid Contractor Registration Certificate
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Bidder/Contractor must attach Valid Civil registration license CertificateFalseTechnical Bid
Bidder/Contractor to qualify for award of this contract must attach Turnover Certificate certified by CA of last five years i.e.,2018-19, 2019-20, 2020-21, 2021-22 and 2022-23 achieved in at least two financial years a minimum financial turnover of usually not less than two times the estimate cost.FalseTechnical Bid
Bidder/Contractor to qualify for award of this contract must attach similar nature of work done certificate not less than rank of Executive Engineer, satisfactorily completed at least 50 percentage of the contract value, as prime contractor, i.e.,2018-19, 2019-20, 2020-21, 2021-22 and 2022-23TrueTechnical Bid
Bidder/Contractor must attach clear scan copy of Nationalized/Scheduled bank DD for difference amount if rates quoted below SR in the name of Chief Officer TP Bilagi .TrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone