createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1706942051785
version4
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee500.00
emd22500.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose12-02-2024 16:00:00
tenderQueryClose05-02-2024 16:00:00
technicalBidOpen13-02-2024 16:05:00
publishedDate03-02-2024 17:59:15
publishedByPostTP_CO_BLG
publishedByUserKPE15339 - DEVENDRA P DHANPAL
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonB D Koti
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08425275261
mobileNumberNone
tenderSupplierListNone
tenderSchedule
createdTs1706942051814
version6
createdDateNone
modifiedDateNone
tenderNumberDMA/2023-24/OW/WORK_INDENT13849
titleCONSTRUCTION OF PUBILC TOILET NEAR KERE WARD NO. 18 IN BILAGI TOWN
descriptionCONSTRUCTION OF PUBILC TOILET NEAR KERE WARD NO. 18 IN BILAGI TOWN
categoryWORKS
categoryTextWorks
ecv900000.00
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2225
locationNameDMA Town Panchayat Bilagi
provisionalAmount900000.0
groupOverheadTotal140588.3
fileNumberTPC/BGL/SBM/OW/38/2023-24
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17069420520000NoneNoneOther WorksCONSTRUCTION OF PUBILC TOILET NEAR KERE WARD NO. 18 IN BILAGI TOWN759411.7
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
241445472306Nonecode01Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in aradius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In All Types of Soil Depth Upto 3Mtrs PWD SR 2023-24 Page No.08. Item No.1.14.1 V1Cum102.0102.022.91FalseNoneNoneFalseNoneFalse2336.820
241445572306Nonecode02Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates PWD CSR 2023-24 Vol-I , P-15 , I. No- 2.1.4Cum6217.06217.05.25FalseNoneNoneFalseNoneFalse32639.250
241445672306Nonecode03Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. PWD CSR 2023-24 Vol-I , P-15 , I. No- 2.2.1Cum6789.966789.962.59FalseNoneNoneFalseNoneFalse17585.99640
241445772306Nonecode04Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.PWD CSR 2023-24 Vol-I , P-16 , I. No-2.3.1Cum10116.810116.83.9FalseNoneNoneFalseNoneFalse39455.520
241445872306Nonecode05Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.PWD CSR 2023-24 Vol-I , P-16 , I. No- 2.5.1Cum11271.011271.01.2FalseNoneNoneFalseNoneFalse13525.20
241445972306Nonecode06Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. Deduct 5% per m3 if rollers are not used and tamping is done manually PWD SOR 2023-24 vol 1 Page no 7 Itm no 1.8Cum474.0474.08.26FalseNoneNoneFalseNoneFalse3915.240
241446072306Nonecode07Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification PWD CSR 2023-24 Vol-I , P-18 , I. No- 2.11 (a)Tonne89457.089457.00.81FalseNoneNoneFalseNoneFalse72460.170
241446172306Nonecode08Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work PWD CSR 2023-24 Vol-2 , P-13 , I. No- 6.2Cum7978.07978.04.7FalseNoneNoneFalseNoneFalse37496.60
241446272306Nonecode09Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of workPWD CSR 2023-24 Vol2I , P-14 , I. No-68Cum7969.07969.021.13FalseNoneNoneFalseNoneFalse168384.970
241446372306Nonecode10Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in foundations and plinth in Cement mortar 1:3 (1 cement : 3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of workPWD CSR 2023-24 Vol-2 , P-14 , I. No- 6.1Sqm1003.01003.012.6FalseNoneNoneFalseNoneFalse12637.80
241446472306Nonecode11Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonry including rounding off corners wherever required smooth redering,providing and removing scaffolding, ncluding cost of materials, labour, curing complete as per specifications and as per direc tions of Engineer-in-charge.PWD SR 20223-24 / Volumme 2 / I.NO-8.3.2/P.NO-41Sqm333.0333.0144.824FalseNoneNoneFalseNoneFalse48226.3920
241446572306Nonecode12Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.PWD CSR 2023-24 Vol-2 , P-16 , I. No- 2.5.1Cum9945.09945.05.1FalseNoneNoneFalseNoneFalse50719.50
241446672306Nonecode13Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.PWD SR 20223-24 / Volumme 2 / I.NO-8.3.2/P.NO-41Sqm323.0323.027.11FalseNoneNoneFalseNoneFalse8756.530
241446772306Nonecode14Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Refer Appendix-I For Formwork, Centering, Scaffolding of painting is 25% (Pg No 115 of Common SR 2021-22) PWD SR 20223-24 / Volumme 2 / I.NO-8.28/P.NO-45Sqm111.25111.2582.37FalseNoneNoneFalseNoneFalse9163.66250
241446872306Nonecode15Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge Refer Appendix-I For Formwork, Centering, Scaffolding of painting is 25% (Pg No 115 of Common SR 2021-22).PWD SR 20223-24 / Volumme 2 / I.NO-8.25/P.NO-45Sqm171.25171.25113.69FalseNoneNoneFalseNoneFalse19469.41250
241446972306Nonecode16Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete.PWD CSR 2023-24 Vol-2 , P-60 , I. No- 9.9Sqm1076.01076.019.65FalseNoneNoneFalseNoneFalse21143.40
241447072306Nonecode17roviding and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg/m2, including pointing in white cement mixed with pigment of matching shade complete..PWD CSR 2023-24 Vol-2 , P-71 , I. No- 9.10.14Sqm1106.01106.050.58FalseNoneNoneFalseNoneFalse55941.480
241447172306Nonecode18Providing & fixing factory made PVC Door frame of size 50x47mm witha wall thickness of 5mm, made out of extruded 5mm rigid PVC foamsheet metered cut at corners & jointed 2 No.s of 150mm long bracketsof 15x15mm M.S Square tube, the entire door frame to be reinforced with19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to thewall using M.S. Screws of 65/80mm size complete as per manufacturersspecification & direction of Engineer-in-charge. .PWD CSR vol 02 Page No.104 Item No.12.54m318.0318.040.6FalseNoneNoneFalseNoneFalse12910.80
241447272306Nonecode19Providing & fixing 30mm thick factory made rigid foam Panelled Door Shutters made from M.S. tube of 19 gauge thickness, size 19x19mm for stiles and 15x15mm for top & bottom rails, covered with heat moulded PVC C channel of 5mm thick sheet & 30 x 50mm wide to form stiles & 5mm thick & 75mm wide PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick 20mm wide PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet fitted in the M.S. Frame, Sealed to the stiles & rails with 5x30mm PVC sheet beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75 mm Aluminium hinges.PWD CSR vol 02 Page No.104 Item No.12.53Sqm1588.01588.014.0FalseNoneNoneFalseNoneFalse22232.00
241447372306Nonecode20Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests (PWD SR 2021-22 Vol:2 P.NO. 123 I.No:14.1.1)Each4884.04884.04.0FalseNoneNoneFalseNoneFalse19536.00
241447472306Nonecode21Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid (PWD SR 2021-22 Vol:2 P.NO. 123 I.No:14.2.1)Each4838.04838.02.0FalseNoneNoneFalseNoneFalse9676.00
241447572306Nonecode22Providing & Fixing on terrace on polythene water storage tank marked with cover & suitable locking arrangements (pwd sr 2021-22 1st addedam vol 2 sl/no 12.1 i.no 13.34Ltr9.09.01000.0FalseNoneNoneFalseNoneFalse9000.00
241447672306Nonecode23Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. Page No.86 Item No.11.34B V2 RIR 9/11/22Kg183.0183.097.41FalseNoneNoneFalseNoneFalse17826.030
241447772306Nonecode24Providing & Fixing CPVC Pipes having thermal steability of hot & cold water supply including fixing the pipe clamp @ 1mtr spacing this includes jointing of pipes etc with CPVC Salvent 20mm nominal od pipe PWD SR 2023-24 1st addendum Vol2 sl no 09 ino 13.31.2m242.0242.015.0FalseNoneNoneFalseNoneFalse3630.00
241447872306Nonecode25Providing & Fixing CPVC Pipes having thermal steability of hot & cold water supply including fixing the pipe clamp @ 1mtr spacing this includes jointing of pipes etc with CPVC Salvent 15mm nominal od pipe PWD SR 2023-24 1st addendum Vol2 sl no 09 ino 13.31.1m309.0309.06.0FalseNoneNoneFalseNoneFalse1854.00
241447972306Nonecode26Providing & Fixing brass bib cock of approved quality pwd sr 2021-2 vol 2 pg no 115 i.no 13.21.1m305.0305.08.0FalseNoneNoneFalseNoneFalse2440.00
241448072306Nonecode27Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. pwd sr 2023-24 vol 2 pg no 119 i.no 13.15m3082.03082.02.0FalseNoneNoneFalseNoneFalse6164.00
241448172306Nonecode28Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps PWD SR 2023-24 vol-2 page no-124 I.No-14.7.1m3082.03082.02.0FalseNoneNoneFalseNoneFalse6164.00
241448272306Nonecode29Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.PWD SR 2023-24 Vol-2 page no 127 I.No- 14.28.2 Flexible pipem92.092.02.0FalseNoneNoneFalseNoneFalse184.00
241448372306Nonecode30Supplying PVC ringtite pipes conforming to IS 4985:2000 with latestamendments and conveying to worksite, rolling and lowering intotrenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:PVC pipes 75mm dia., 6 kg/sqcm & class 3 PWD SR 2021-22 Page no-134 I.NO-1.5m370.0370.010.0FalseNoneNoneFalseNoneFalse3700.00
241448472306Nonecode31Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete:15 mm nominal bore (PWD SR 2023-24 Vol:2 P.NO.115 I.No:13.5.1)m296.0296.02.0FalseNoneNoneFalseNoneFalse592.00
241448572306Nonecode32Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.PWD SR 2023-24 Vol:2 P.NO.128 I.No:14.31)m1220.01220.02.0FalseNoneNoneFalseNoneFalse2440.00
241448672306Nonecode33Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA. On wall/ ceiling / Rafter / Girders PWD Electrical SR 2022-23 Page No.45 Item No.13.7.1Each122.0122.01.0FalseNoneNoneFalseNoneFalse122.00
241448772306Nonecode34Supplying of .....feet -PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burninghours & 70% lumen maintenance with CRI 80. PowerInput: 220-240V@ 50/60Hz & Power factor 0.9 along with CEapproved. 2 years Warranty against any manufacturing defectworking under standard electrical condition.LED light fitting 1 x 4' - 20/22 W PWD Electrical SR 2022-23 Page No.34 Item No.11.3.2Each690.0690.06.0FalseNoneNoneFalseNoneFalse4140.00
241448872306Nonecode35Fixing of ..... Amps TPST / change over switch / Contactor along with neutral link with screws, bolts, nuts and wiring using required capacity wires and circuit labeling 15A to 63A TPST (PWD Electrical SR 2022-23 P no 46 I no 13.18.1)Each278.0278.01.0FalseNoneNoneFalseNoneFalse278.00
241448972306Nonecode36Supplying of TPST with rewirable porcelain channels in SM enclosure. Made out of 14 SWG powder coated paint of approved colour. (PWD Electrical SR 2022-23 P no. 10 I no 5.5.2) 63Amps (PWD Electrical SR 2022-23 Page No.02 Item No.1.8.2Each4193.934193.931.0FalseNoneNoneFalseNoneFalse4193.930
241449072306Nonecode37Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box,elbows, screws at an interval of 300 mm .... etc. as required.25mmm35.035.020.0FalseNoneNoneFalseNoneFalse700.00
241449172306Nonecode38Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. (PWD Electrical SR 2022-23 P No 8 I no 3.3.7) 16-18 WayEach294.0294.01.0FalseNoneNoneFalseNoneFalse294.00
241449272306Nonecode39Supplying and fixing superior quality modular switch mountingpolycarbonate plate with necessary supporting back plate withrequired nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.16-18 Module . (PWD Electrical SR 2022-23 Page No.8 Item No.3.5.8Each457.0457.05.0FalseNoneNoneFalseNoneFalse2285.00
241449372306Nonecode40Wiring for lighting/power circuit using one of FRLS PVCnsulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments 1.5Sqmm (PWD Electrical SR 2022-23 Page No.05 Item No.2.3.2m26.026.020.0FalseNoneNoneFalseNoneFalse520.00
241449472306Nonecode41Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. (PWD Electrical SR 2022-23 Page No.05 Item No.2.3.4m63.063.020.0FalseNoneNoneFalseNoneFalse1260.00
241449572306Nonecode42Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS1293 and IS 3654 6A 2 Way (PWD Electrical SR 2022-23 Page No.8 Item No.3.1.1Each128.0128.01.0FalseNoneNoneFalseNoneFalse128.00
241449672306Nonecode43Supplying and fixing of modular switch & connected accessorieson existing modular switch plate as per IS 3854 and IS 1293.6A Three Way socket (PWD Electrical SR 2022-23 Page No.9 Item No.3.6.3Each171.0171.01.0FalseNoneNoneFalseNoneFalse171.00
241449772306Nonecode44Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.600w dimmer (PWD Electrical SR 2022-23 Page No.9 Item No.3.6.6Each329.0329.01.0FalseNoneNoneFalseNoneFalse329.00
241449872306Nonecode45Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.50-63 A TPN (PWD Electrical SR 2022-23 Page No.18 Item No.5.18.9Each3088.03088.01.0FalseNoneNoneFalseNoneFalse3088.00
241449972306Nonecode46Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure.6 Way SP & N (PWD Electrical SR 2022-23 Page No.18 Item No.5.19.2Each1186.01186.01.0FalseNoneNoneFalseNoneFalse1186.00
241450072306Nonecode47Supplying and fixing Wiring Earth Electrode For grounding conduits ic cutouts on the meter board using 40mm dia 2.90mm thick GI Pipe 2.50mtr long burried in a pit the pit should be filled up with equal propotion of salt & charcoal 150mm alll around the pipe to complete depth (PWD Electrical SR 2022-23 Page No.54 Item No.12.56Each3510.03510.01.0FalseNoneNoneFalseNoneFalse3510.00
241450172306Nonecode48For Electrical & Hescom ChargesLS5000.05000.01.0FalseNoneNoneFalseNoneFalse5000.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17069420530000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17069420530000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17069420530000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17069604890000NoneNoneELIGIBILITYConditional tenders are not acceptedNone
17069604940000NoneNoneELIGIBILITYThe employer reserves the rights to Reject or accept any or all the tenders without assigning any reasons.None
17069604980000NoneNoneELIGIBILITYAll safety precautions, warning signs, night illumination, reflectors, deployment of security guards has to be ensured so that no untoward incidents happens on account of negligence or any project activity. Contractor should indemnify the client to that extentNone
17069605030000NoneNoneELIGIBILITYThe Tenderer should furnish all the necessary original documents mentioned above at the time of evaluation of BidNone
17069605100000NoneNoneELIGIBILITYThe tenderer should maintain the work/Supply during the defective liability period for 2 years after completion of the work.None
17069605180000NoneNoneELIGIBILITYRoyalty on construction materials and other taxes will be deducted as per prevailing Govt Orders.None
17069605240000NoneNoneELIGIBILITYContractors should follow strictly prevailing rules of labour act and a sum of amounting to 1% of the bill amount will be deducted towards construction labour fund as per govt order.None
17069605420000NoneNoneELIGIBILITYThis work should be Inspected by the 3rd party Agency and after getting 3rd party report satisfactory payment will be made.None
17069605720000NoneNoneELIGIBILITYAll scanned documents to be uploaded shall be in original and the Chief Officer TP Bilagi reserves the right to verify the documents before approval.None
17069605790000NoneNoneELIGIBILITYThe earnest money deposit may be forfeited if the documents submitted the Tenderer found to misleading/forged or fake.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneSummary of financial turnover certificate duly certified by CA during last 5 years 2018-19 to 2022-23 (With Valid UDIN Number)Financial StatusValid Contractor Registration Certificate
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneAdditional performance Security (Below DD) for Unbalanced Tenders in the Form of DD/FDR/BC from Nationalized Or Scheduled Bank should be scanned and uploadFinancial StatusSummary of financial turnover certificate duly certified by CA during last 5 years 2018-19 to 2022-23 (With Valid UDIN Number)
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Additional performance Security Below DD
NoneNoneNoneNoneSatisfactorily completed as a prime Contractor for at least one similar nature of work to an extent of 50 percent of the cost of the work during last 5 years 2018-19 to 2022-23,work done certificate should be countersigned by a district level officer not below the rank of executive engineerFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneValid Contractor Registration CertificateOthersValid Contractor Registration Certificate
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneGST Registration CertificateOthersGST Registration Certificate
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneGST Registration
NoneNoneNoneNoneContractor Name and Details address, Email Id Or Whatsapp mobile no.OthersContractor Name and Details address, Email Id Or Whatsapp mobile no.
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Contractor Name and Details address, Email Id Or Whatsapp mobile no.
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Bidder/Contractor must attach Valid Civil registration license CertificateFalseTechnical Bid
Bidder/Contractor to qualify for award of this contract must attach Turnover Certificate certified by CA of last five years i.e.,2018-19, 2019-20, 2020-21, 2021-22 and 2022-23 achieved in at least two financial years a minimum financial turnover of usually not less than two times the estimate cost.FalseTechnical Bid
Bidder/Contractor to qualify for award of this contract must attach similar nature of work done certificate not less than rank of Executive Engineer, satisfactorily completed at least 50 percentage of the contract value, as prime contractor, i.e.,2018-19, 2019-20, 2020-21, 2021-22 and 2022-23FalseTechnical Bid
Bidder/Contractor must attach clear scan copy of Nationalized/Scheduled bank DD for difference amount if rates quoted below SR in the name of Chief Officer TP Bilagi .FalseTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone