createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1707113682787
version6
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeEXCLUSIVE_TAX
tenderFee5000.00
emd1479000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose20-02-2024 17:00:00
tenderQueryClose13-02-2024 11:00:00
technicalBidOpen22-02-2024 11:00:00
publishedDate05-02-2024 13:45:47
publishedByPostAPMC_SEC_BYD
publishedByUserKPE10225 - SATEESHA H Y
bidValidityPeriod90
noOfCalls1
preBidMeetingDate13-02-2024 11:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonVIKAS
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08375228443
mobileNumber8073322418
tenderSupplierListNone
tenderSchedule
createdTs1707113682809
version8
createdDateNone
modifiedDateNone
tenderNumberAPMC/2023-24/BD/WORK_INDENT273
titleCONSTRUCTION OF COLD STORAGE AT CHIKBASUR SUBMARKET YARD OF APMC BYADGI UNDER RIDF-29 SCHEME 2023-24
descriptionCONSTRUCTION OF COLD STORAGE AT CHIKBASUR SUBMARKET YARD OF APMC BYADGI UNDER RIDF-29 SCHEME 2023-24
categoryWORKS
categoryTextWorks
ecv98545367.65
deptNameAgriculture Produce Marketing Committee
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location5409
locationNameSECRETARY APMC Office BYADGI
provisionalAmount100000000.0
groupOverheadTotal15032352.0
fileNumberAPMC/BYADGI/BD/RIDF/2023/24
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17071136830000NoneNoneBuildingsCONSTRUCTION OF COLD STORAGE AT CHIKBASUR SUBMARKET YARD OF APMC BYADGI UNDER RIDF-29 SCHEME 2023-2483513015.65
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
243647273308NoneBYD01Earth work excavation for Foundation by mechanical means for all kind of soil & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the workCum102.0102.01227.795FalseNoneNoneFalseNoneFalse125235.090
243647373308NoneBYD02Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and including cost of labour, tools, usage& other appurtenances required to complete the work. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the workCum484.0484.0120.0FalseNoneNoneFalseNoneFalse58080.00
243647473308NoneBYD03Filling in foundation with granite / trap broken metal 100mm. and down size, with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the workCum2682.02682.0217.6738FalseNoneNoneFalseNoneFalse583801.13160
243647573308NoneBYD04Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the workCum5664.05664.0243.0693FalseNoneNoneFalseNoneFalse1376744.51520
243647673308NoneBYD05Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the workCum6217.06217.0212.4238FalseNoneNoneFalseNoneFalse1320638.76460
243647773308NoneBYD06Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form work for FootingsCum6842.886842.88195.5095FalseNoneNoneFalseNoneFalse1337848.047360
243647873308NoneBYD07Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form work for RCC wallCum7128.07128.064.4218FalseNoneNoneFalseNoneFalse459198.59040
243647973308NoneBYD08Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form work for PedestalCum11016.011016.0110.823FalseNoneNoneFalseNoneFalse1220826.1680
243648073308NoneBYD09Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form work for Lintel & BeamsCum10948.810948.80.8636FalseNoneNoneFalseNoneFalse9455.383680
243648173308NoneBYD10Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form work for chejjasCum9922.359922.354.914FalseNoneNoneFalseNoneFalse48758.42790
243648273308NoneBYD11Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6842.886842.8816.9875FalseNoneNoneFalseNoneFalse116243.4240
243648373308NoneBYD12Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum9720.09720.04.3334FalseNoneNoneFalseNoneFalse42120.6480
243648473308NoneBYD13Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workSqm1231.01231.037.7024FalseNoneNoneFalseNoneFalse46411.65440
243648573308NoneBYD14Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workt89457.089457.036.559FalseNoneNoneFalseNoneFalse3270458.4630
243648673308NoneBYD15Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workCum6323.06323.0228.023FalseNoneNoneFalseNoneFalse1441789.4290
243648773308NoneBYD16Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works and other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workCum6386.236386.2315.6FalseNoneNoneFalseNoneFalse99625.1880
243648873308NoneBYD17Providing 12 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workSqm255.0255.065.795FalseNoneNoneFalseNoneFalse16777.7250
243648973308NoneBYD18Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workSqm349.0349.0173.044FalseNoneNoneFalseNoneFalse60392.3560
243649073308NoneBYD19Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm312.0312.057.9FalseNoneNoneFalseNoneFalse18064.80
243649173308NoneBYD20Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineer- in-Charge.Kgs64.064.09.6693FalseNoneNoneFalseNoneFalse618.83520
243649273308NoneBYD21Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workKgs183.0183.072.0FalseNoneNoneFalseNoneFalse13176.00
243649373308NoneBYD22Providing & fixing of 2-track x 2panel sliding windows made out of multi chambered UPVC(Matching to RAL9016) sections and with minimum TiO2(Titanium Dioxide) at 6 PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets grey color having isolated drainage and reinforced with Galvanized Iron profile through out the window frame. The outer frame having an overall size of 44mm width x 40mmheight with reinforcement of 1mm thickness and Sash with overall size of 27mm X 53mm with UPVC honeycomb structure inside in lieu of GI reinforcement. Coextruded Glazing bead for fixing of glass shall be of size 9.5mm x 21.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with Crescent Locks. Wall thickness of frame & sash shall be of 2 mm.Maximum possible size 1219mm x 1219mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workSqm5023.05023.02.88FalseNoneNoneFalseNoneFalse14466.240
243649473308NoneBYD23Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workSqm2633.02633.010.8FalseNoneNoneFalseNoneFalse28436.40
243649573308NoneBYD24Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance 1mm), with wall thickness 2.0 mm (0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm ( 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of Engineer- in-charge 42x50 mm PVC Extruded section with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workm250.95250.9512.0FalseNoneNoneFalseNoneFalse3011.40
243649673308NoneBYD25Providing& fixing of Openable door made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 900mm x 2400mm (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workSqm6557.256557.253.78FalseNoneNoneFalseNoneFalse24786.4050
243649773308NoneBYD26Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workSqm3660.03660.02.57FalseNoneNoneFalseNoneFalse9406.20
243649873308NoneBYD27Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and in- cluding water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workSqm137.0137.065.795FalseNoneNoneFalseNoneFalse9013.9150
243649973308NoneBYD28Finishing walls with water proofing cement paint of required shade New work (Two coats applied at 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workSqm89.089.0173.044FalseNoneNoneFalseNoneFalse15400.9160
243650073308NoneBYD29Finishing with Epoxy paint (two coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workSqm176.0176.02200.0FalseNoneNoneFalseNoneFalse387200.00
243650173308NoneBYD30Painting with synthetic enamel paint of approved brand and manufacture to give an even shade Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form work.Sqm115.0115.027.36FalseNoneNoneFalseNoneFalse3146.40
243650273308NoneBYD31Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workMtr291.0291.0128.0FalseNoneNoneFalseNoneFalse37248.00
243650373308NoneBYD32Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, with all leads and lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workCum266.0266.01046.9896FalseNoneNoneFalseNoneFalse278499.23360
243650473308NoneBYD33Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer- in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workSqm568.0568.03346.6FalseNoneNoneFalseNoneFalse1900868.80
243650573308NoneBYD34ProviProviding and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (0.05 %) total coated thickness, Zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete Ridges plain (500 - 600mm) with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workMtr451.0451.048.0FalseNoneNoneFalseNoneFalse21648.00
243650673308NoneBYD35ProviProviding and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (0.05 %) total coated thickness, Zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete Gutter (600 mm over all girth) with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workMtr1074.01074.096.0FalseNoneNoneFalseNoneFalse103104.00
243650773308NoneBYD36ProviProviding and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (0.05 %) total coated thickness, Zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete Flashings/ Aprons.( Upto 600 mm) with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workMtr413.0413.0156.0FalseNoneNoneFalseNoneFalse64428.00
243650873308NoneBYD37Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workKg136.0136.0100000.0FalseNoneNoneFalseNoneFalse13600000.00
243650973308NoneBYD38Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workKg137.36137.3692000.0FalseNoneNoneFalseNoneFalse12637120.00
243651073308NoneBYD39Providing, Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications, to work site with testing of as per instructions of engineer incharge of work and latest amendments etc complete.1 HP/0.75kW - 7 STG(stage)Nos13113.013113.01.0FalseNoneNoneFalseNoneFalse13113.00
243651173308NoneBYD40Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments1x3x2.5 m2Mtr85.085.030.0FalseNoneNoneFalseNoneFalse2550.00
243651273308NoneBYD41Supply and delivery at site brand new best make starter/ control panel suitable for following HP centrifugal pump confirming with ISI mark and its latest amendments. Upto 7.5 HP centrifugal pumpEach9500.09500.01.0FalseNoneNoneFalseNoneFalse9500.00
243651373308NoneBYD42Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5Each5642.05642.09.0FalseNoneNoneFalseNoneFalse50778.00
243651473308NoneBYD43Construction of Granular Sub-Base of required grading as per design mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 For Grading -V Material with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workCum2487.02487.0138.42FalseNoneNoneFalseNoneFalse344250.540
243651573308NoneBYD44Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 14:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 140 kg/ m3 , optimum moisture content to be determined during trial length construction, concrete strength not to be less than 7 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workCum4920.04920.0109.88FalseNoneNoneFalseNoneFalse540609.60
243651673308NoneBYD45Providing and constructing un-reinforced plain cement concrete pavement, thickness as per design, over a prepare sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS:383:2016:, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including construction joints, primer, sealant, curing of concrete slabs for 14-days, and water finishing to lines and grade as per drawing and technical specification clause 1501 with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments etc complete. as per the directions of the Engineer-in-charge of the work. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workCum6754.06754.0219.76FalseNoneNoneFalseNoneFalse1484259.040
243651773308NoneBYD46Open Conduit System Supplying heavy gauge PVC conduit pipe dia mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.25mm dia 2mm thick. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workMtr81.081.01050.0FalseNoneNoneFalseNoneFalse85050.00
243651873308NoneBYD47Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete.upto 50mm conduit in brick wall with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workMtr29.029.040.0FalseNoneNoneFalseNoneFalse1160.00
243651973308NoneBYD48Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete.upto 50mm conduit CC floor. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workMtr69.069.020.0FalseNoneNoneFalseNoneFalse1380.00
243652073308NoneBYD49Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, screws at an interval of 300mm etc. as required.25mm with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workMtr35.035.020.0FalseNoneNoneFalseNoneFalse700.00
243652173308NoneBYD50Supplying PVC/GI flexible conduit pipe…mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of thepi pe terminated completely 25mm. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workMtr22.022.0350.0FalseNoneNoneFalseNoneFalse7700.00
243652273308NoneBYD51Supplying PVC/GI flexible conduit pipe mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of thepi pe terminated completely 32mm. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workMtr29.029.020.0FalseNoneNoneFalseNoneFalse580.00
243652373308NoneBYD52Supplying And Fixing Metal Fan Box with Round Hook with all leads and lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo117.0117.01.0FalseNoneNoneFalseNoneFalse117.00
243652473308NoneBYD53Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694 and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Short point upto 3Mtr from tapping point to out let via switch with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workPoint269.0269.02.0FalseNoneNoneFalseNoneFalse538.00
243652573308NoneBYD54Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Medium point above 3M. upto 6M from tapping point to out let via switch with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workPoint379.0379.02.0FalseNoneNoneFalseNoneFalse758.00
243652673308NoneBYD55Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) and 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Long point above 6Mtr. upto 10M from tapping point to out let via switch with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workPoint555.0555.012.0FalseNoneNoneFalseNoneFalse6660.00
243652773308NoneBYD56Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Two outlet in a row, above 3Mtr upto 6Mtr from tapping point to out let via switches with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workPoint677.0677.016.0FalseNoneNoneFalseNoneFalse10832.00
243652873308NoneBYD57Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694 and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Three outlet in a row, above 6Mtr upto 10Mtr from tapping point to out let via switches with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workPoint989.0989.01.0FalseNoneNoneFalseNoneFalse989.00
243652973308NoneBYD58Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.1 sqmm with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workMtr19.019.0140.0FalseNoneNoneFalseNoneFalse2660.00
243653073308NoneBYD59Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.1.5 sqmm with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workMtr26.026.0455.0FalseNoneNoneFalseNoneFalse11830.00
243653173308NoneBYD60Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.2.5 sqmm with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workMtr42.042.0410.0FalseNoneNoneFalseNoneFalse17220.00
243653273308NoneBYD61Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.4 sqmm with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workMtr63.063.0135.0FalseNoneNoneFalseNoneFalse8505.00
243653373308NoneBYD62Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.6 sqmm with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workMtr92.092.045.0FalseNoneNoneFalseNoneFalse4140.00
243653473308NoneBYD63Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS- 694:2010 3C x 2.5 mm2 with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workMtr113.0113.0225.0FalseNoneNoneFalseNoneFalse25425.00
243653573308NoneBYD64Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.4-5 Way with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo137.0137.04.0FalseNoneNoneFalseNoneFalse548.00
243653673308NoneBYD65Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.6 Way with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo173.0173.02.0FalseNoneNoneFalseNoneFalse346.00
243653773308NoneBYD66Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc complete.8 Way with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo219.0219.04.0FalseNoneNoneFalseNoneFalse876.00
243653873308NoneBYD67Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc complete.16Way with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo294.0294.02.0FalseNoneNoneFalseNoneFalse588.00
243653973308NoneBYD68Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.4 Module with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo175.0175.04.0FalseNoneNoneFalseNoneFalse700.00
243654073308NoneBYD69Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.6 Module with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo234.0234.02.0FalseNoneNoneFalseNoneFalse468.00
243654173308NoneBYD70Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.8 Module with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo284.0284.04.0FalseNoneNoneFalseNoneFalse1136.00
243654273308NoneBYD71Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.16-18 Module with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo397.0397.02.0FalseNoneNoneFalseNoneFalse794.00
243654373308NoneBYD72Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6Amps one way. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo102.0102.043.0FalseNoneNoneFalseNoneFalse4386.00
243654473308NoneBYD73Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6Amps two way. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo166.0166.06.0FalseNoneNoneFalseNoneFalse996.00
243654573308NoneBYD74Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6Amps 3way socket. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo171.0171.010.0FalseNoneNoneFalseNoneFalse1710.00
243654673308NoneBYD75Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.Stepped Fan Regulator. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo357.0357.04.0FalseNoneNoneFalseNoneFalse1428.00
243654773308NoneBYD76Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.16Amps one way switch with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo180.0180.02.0FalseNoneNoneFalseNoneFalse360.00
243654873308NoneBYD77Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6/16Amps universal socket with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo236.0236.02.0FalseNoneNoneFalseNoneFalse472.00
243654973308NoneBYD78Supplying and fixing/replacing of 6/16/32Amps electrical accessories on existing switch board.6A Batten Holder. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo74.074.012.0FalseNoneNoneFalseNoneFalse888.00
243655073308NoneBYD79Supplying of on load change over switches 4poles, AC23 A Duty,415V,50Hz,AC Supply.With all accessories.(SM Enclosure Sheet Metal Execution) 800 A with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo58167.058167.01.0FalseNoneNoneFalseNoneFalse58167.00
243655173308NoneBYD80Supplying and fixing Moulded Case Circuit Breaker(MCCB) over theexisting wood/panel board using necessary screws,bolts,nuts,necessary phase separators,handle and wiring complete.Protection of Over load and Short circuit with adjustable thermal magnetic release,Microprocessor release shall have Earth Fault as per IS/IEC60947 2.(Icu=100%lcs).In 4P MCCB,all Poles should have protection for Short Cicrcuit / Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non Priority loads must be available in the MCCB.MCCB shall be provided with double insulation(insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open)Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.700-800 A 50 kA with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo49900.049900.02.0FalseNoneNoneFalseNoneFalse99800.00
243655273308NoneBYD81Supplying and fixing Moulded Case Circuit Breaker(MCCB) over theexisting wood/panel board using necessary screws,bolts,nuts,necessary phase separators,handle and wiring complete.Protection of Over load and Short circuit with adjustable thermal magnetic release,Microprocessor release shall have Earth Fault as per IS/IEC60947 2.(Icu=100%lcs).In 4P MCCB,all Poles should have protection for Short Cicrcuit / Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non Priority loads must be available in the MCCB.MCCB shall be provided with double insulation(insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open)Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.500-630 A 50 kA with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo41899.041899.01.0FalseNoneNoneFalseNoneFalse41899.00
243655373308NoneBYD82Supplying and fixing Moulded Case Circuit Breaker(MCCB) over theexisting wood/panel board using necessary screws,bolts,nuts,necessary phase separators,handle and wiring complete.Protection of Over load and Short circuit with adjustable thermal magnetic release,Microprocessor release shall have Earth Fault as per IS/IEC60947 2 (Icu=100%lcs)In 4P MCCB,all Poles should have protection for Short Cicrcuit / Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non Priority loads must be available in the MCCB.MCCB shall be provided with double insulation(insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open)Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.250 A 25 kA with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo21391.021391.01.0FalseNoneNoneFalseNoneFalse21391.00
243655473308NoneBYD83Supplying and fixing Moulded Case Circuit Breaker(MCCB) over theexisting wood/panel board using necessary screws,bolts,nuts,necessary phase separators,handle and wiring complete.Protection of Over load and Short circuit with adjustable thermal magnetic release,Microprocessor release shall have Earth Fault as per IS/IEC60947 2.(Icu=100%lcs).In 4P MCCB,all Poles should have protection for Short Cicrcuit / Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non Priority loads must be available in the MCCB.MCCB shall be provided with double insulation(insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open)Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.200 A 25 kA with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo17301.017301.01.0FalseNoneNoneFalseNoneFalse17301.00
243655573308NoneBYD84Supplying and fixing Moulded Case Circuit Breaker(MCCB) over theexisting wood/panel board using necessary screws,bolts,nuts,necessary phase separators,handle and wiring complete.Protection of Over load and Short circuit with adjustable thermal magnetic release,Microprocessor release shall have Earth Fault as per IS/IEC60947 2.(Icu=100%lcs).In 4P MCCB,all Poles should have protection for Short Cicrcuit / Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non Priority loads must be available in the MCCB.MCCB shall be provided with double insulation(insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open)Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.160 A 25 kA with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo13447.013447.02.0FalseNoneNoneFalseNoneFalse26894.00
243655673308NoneBYD85Supplying and fixing Moulded Case Circuit Breaker(MCCB) over theexisting wood/panel board using necessary screws,bolts,nuts,necessary phase separators,handle and wiring complete.Protection of Over load and Short circuit with adjustable thermal magnetic release,Microprocessor release shall have Earth Fault as per IS/IEC60947 2.(Icu=100%lcs) In 4P MCCB,all Poles should have protection for Short Cicrcuit / Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non Priority loads must be available in the MCCB.MCCB shall be provided with double insulation(insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open)Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.125 A 25 kA with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo10341.010341.04.0FalseNoneNoneFalseNoneFalse41364.00
243655773308NoneBYD86Supplying and fixing of Shunt trip suitable for MCCB.CBCT with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo1703.01703.02.0FalseNoneNoneFalseNoneFalse3406.00
243655873308NoneBYD87Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 Amps SP. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo415.0415.040.0FalseNoneNoneFalseNoneFalse16600.00
243655973308NoneBYD88Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 Amps DP with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo739.0739.06.0FalseNoneNoneFalseNoneFalse4434.00
243656073308NoneBYD89Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 Amps TPN. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo1717.01717.05.0FalseNoneNoneFalseNoneFalse8585.00
243656173308NoneBYD90Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.50-63 Amps TPN. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo3088.03088.043.0FalseNoneNoneFalseNoneFalse132784.00
243656273308NoneBYD91Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc with provision for fixing suitable type capacity MCBs single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure.II - Double Door 16 Way SP & N with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo2908.02908.01.0FalseNoneNoneFalseNoneFalse2908.00
243656373308NoneBYD92Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V up to 300mA sensitivity on existing wood/panel board 63 Amps 4 pole with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo5545.05545.01.0FalseNoneNoneFalseNoneFalse5545.00
243656473308NoneBYD93Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo9255.09255.02.0FalseNoneNoneFalseNoneFalse18510.00
243656573308NoneBYD94Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo9315.09315.02.0FalseNoneNoneFalseNoneFalse18630.00
243656673308NoneBYD95Supplying, fixing and wiring 1000/5A to 1600/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo840.0840.02.0FalseNoneNoneFalseNoneFalse1680.00
243656773308NoneBYD96Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo515.0515.036.0FalseNoneNoneFalseNoneFalse18540.00
243656873308NoneBYD97Supplying amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete.100Amps 4x30x6mm Aluminium Strips with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workMtr2465.02465.06.0FalseNoneNoneFalseNoneFalse14790.00
243656973308NoneBYD98Supplying amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete.250Amps 4x30x10mm Aluminium Strips with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workMtr3435.03435.08.0FalseNoneNoneFalseNoneFalse27480.00
243657073308NoneBYD99Supplying amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete.1000 A double run of 4 x 60 x 10 mm Aluminium Strips with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workMtr10580.010580.08.0FalseNoneNoneFalseNoneFalse84640.00
243657173308NoneBYD100Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.40x40x 6mm with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workMtr305.0305.024.0FalseNoneNoneFalseNoneFalse7320.00
243657273308NoneBYD101Supplying and fixing angle iron frame work fabricated out of M.S. angle iron and M.S. flat with bolts, washers etc and painted with 2 coats of red oxide and then two coats of approved paint.50x50x6mm with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workMtr395.0395.024.0FalseNoneNoneFalseNoneFalse9480.00
243657373308NoneBYD102Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat with bolts, washers etc and painted with 2 coats of red oxide and then two coats of approved paint.75 x 75 x 6 mm with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workMtr555.0555.012.0FalseNoneNoneFalseNoneFalse6660.00
243657473308NoneBYD103Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat with bolts, washers etc and painted with 2 coats of red oxide and then two coats of approved paint.50X100X50X6mm C channel with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workMtr756.0756.024.0FalseNoneNoneFalseNoneFalse18144.00
243657573308NoneBYD104Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc and painted with 2 coats of red oxide and then two coats of approved paint.75 x 150 x 75 x 6 mm C channel with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workMtr926.0926.012.0FalseNoneNoneFalseNoneFalse11112.00
243657673308NoneBYD105Supplying and fixing of 3 pole power contactor with NO/NC contacts on existing wood/panel boaard using necessary bolts,nuts, washers and wiring etc completee with ac-3 rating and as per IS-13947 60Amps. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo5950.05950.07.0FalseNoneNoneFalseNoneFalse41650.00
243657773308NoneBYD106Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 V grade, for power factor improvement of rotating machineries likeinduction motor. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workKvar480.0480.0175.0FalseNoneNoneFalseNoneFalse84000.00
243657873308NoneBYD107Supplying, fixing and wiring Automatic Power Factor controller circuit unit fully, static units controlled by 14 stage microprocessor operation, relays LED display, self programming function for power stages and operating logic checking facility for healthy and efficient of each individual capacitor bank, measurement of network harmonics with indication when limit values are exceeded, Comprehensive displays with large, three phase LED display, Long term memory for settings, protection for over voltage, power factor correction fault and no voltage, to connect/ disconnect banks, with automatic recognition or with standard programs. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo21640.021640.01.0FalseNoneNoneFalseNoneFalse21640.00
243657973308NoneBYD108Fabricating supplying and mounting MS box made out SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc complete.14SWG with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workSq CM0.50.5425000.0FalseNoneNoneFalseNoneFalse212500.00
243658073308NoneBYD109Supply and fixing of Auxiliary contactor relay with 2 NO and 2 NC contact and operating coil voltage of 220V to 260V. fixed on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workEach1330.01330.04.0FalseNoneNoneFalseNoneFalse5320.00
243658173308NoneBYD110Supplying,fixing,wiring,earth electrode for grounding conduits,I.C.cutouts and other equipment's on the mete rboard using 40mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit.The pit should be filled with equal proportion of salt and char coal150mm all-round the pipe to complete depth.The connection from the pipe to the conduit etc.,is to be established through GI wire of size as per lSI specification7.3.3.of IS732 using 12 mm dia bolts,nuts,washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo3510.03510.08.0FalseNoneNoneFalseNoneFalse28080.00
243658273308NoneBYD111Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. GI strip GI Strip. 25x3mm with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workMtr82.082.040.0FalseNoneNoneFalseNoneFalse3280.00
243658373308NoneBYD112Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. GI strip Copper strip. 25x3mm. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workMtr570.0570.020.0FalseNoneNoneFalseNoneFalse11400.00
243658473308NoneBYD113Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600x600x3mm Copper plate. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo7421.07421.02.0FalseNoneNoneFalseNoneFalse14842.00
243658573308NoneBYD114Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG. Copper Wire with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workMtr105.0105.0200.0FalseNoneNoneFalseNoneFalse21000.00
243658673308NoneBYD115Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 1.5sqmm with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo3.03.04.0FalseNoneNoneFalseNoneFalse12.00
243658773308NoneBYD116Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 2.5sqmm with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo4.04.010.0FalseNoneNoneFalseNoneFalse40.00
243658873308NoneBYD117Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 4sqmm with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo7.07.08.0FalseNoneNoneFalseNoneFalse56.00
243658973308NoneBYD118Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 6sqmm with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo7.07.09.0FalseNoneNoneFalseNoneFalse63.00
243659073308NoneBYD119Providing and laying in position 100mm dia stone ware pipe in existing trench. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workMtr215.0215.0100.0FalseNoneNoneFalseNoneFalse21500.00
243659173308NoneBYD120Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.15" Sweep (450mm) with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo1492.01492.01.0FalseNoneNoneFalseNoneFalse1492.00
243659273308NoneBYD121Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS:1709/1984 with latest amendment, Rated voltage 220 V/ 50 Hz, Rated power input 48 W 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min) Rated speed 350 10% RPM, Rated air delivery 210 10% Cubic Meter Minimum, Rated service value 4.2 CMM / Watt, Three Blades of blade leaf 1.05mm thick Aluminium Alloy sheet, Class B motor insulation,Bearing Two ball bearings, Top 6202, Bottom 6201 , as per IS specification, Motor wdg. Temp rise Shall not exceed 75 degC over and ambient of 40 0C by resistance method at 245Volts, Insulation resistance Shall not be less than Two Mega Ohms (2 M Ohms), Leakage current Should not exceed 210Micro Amp, Power input, watt& current , Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty48 Sweep 5 Star (1200mm) with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo4303.04303.01.0FalseNoneNoneFalseNoneFalse4303.00
243659373308NoneBYD122Supplying wall mounting fan suitable to operate at singlephase.400mm Sweep 230v A.C. supply. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo3212.03212.01.0FalseNoneNoneFalseNoneFalse3212.00
243659473308NoneBYD123Supplying of feet - PVC Batten with integrated LED tube. W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V at 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fighting 1 x 2- 9/10w. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo551.0551.02.0FalseNoneNoneFalseNoneFalse1102.00
243659573308NoneBYD124Supplying of feet - PVC Batten with integrated LED tube.W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V at 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fighting 1 x4- 20/22 w. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo690.0690.014.0FalseNoneNoneFalseNoneFalse9660.00
243659673308NoneBYD125Supplying of recess/surface mounting non integrated type LED down light W luminaire comprising of pressure decast/ extruded aluminium housing, with spring loaded false ceiling clamps, LED of Power/COB with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per watt, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit,THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.15-18W. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo1671.01671.024.0FalseNoneNoneFalseNoneFalse40104.00
243659773308NoneBYD126Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation.Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr at Lumen Maintenance of 70% maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 and LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with W System Power consumption. LED Efficiency130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design and Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source.LED Streetlight 40W. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo4024.04024.07.0FalseNoneNoneFalseNoneFalse28168.00
243659873308NoneBYD127Supplying and Fixing........mm dia class A GI pipe bracket up to 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed forfixing MV/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/tubular pole, using suitable clamps, bolts, nuts and wiring using suitable capacity wires. Using 25mm dia G.I.Pipe. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo1203.01203.07.0FalseNoneNoneFalseNoneFalse8421.00
243659973308NoneBYD128Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo162.0162.07.0FalseNoneNoneFalseNoneFalse1134.00
243660073308NoneBYD129Fixing all types and all capacities of fluorescent / false ceiling/ spot light / CFL / LED fittings indoor on the wall / ceiling /rafters / girders using 23/0.0076 twin twisted PVC insulatedwires, required Nos of round blocks and clamps.On wall/ ceiling / Rafter / Girders. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo122.0122.040.0FalseNoneNoneFalseNoneFalse4880.00
243660173308NoneBYD130Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and S hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo315.0315.02.0FalseNoneNoneFalseNoneFalse630.00
243660273308NoneBYD131Fixing one exhaust fan after making a suitable notch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 A, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo707.0707.01.0FalseNoneNoneFalseNoneFalse707.00
243660373308NoneBYD1322 mm thick perforated cable GI tray with on existing MS angle support using necessary GI bolts/nuts and washer or welding as required.450 x 50 mm with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workMtr913.0913.0100.0FalseNoneNoneFalseNoneFalse91300.00
243660473308NoneBYD1331.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975. 16 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm) with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workKm141842.0141842.00.65FalseNoneNoneFalseNoneFalse92197.30
243660573308NoneBYD134Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff.2.5 to 25 Sqmm with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workKm20886.020886.00.65FalseNoneNoneFalseNoneFalse13575.90
243660673308NoneBYD1351.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thick with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workness and resistivity as per IS-3975.185 Sqmm, 3.5 Core, (28 GI Strips - 4 x 0.8 mm)Km691218.0691218.00.75FalseNoneNoneFalseNoneFalse518413.50
243660773308NoneBYD136Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff.120 to 240 Sqmm with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workKm32278.032278.00.75FalseNoneNoneFalseNoneFalse24208.50
243660873308NoneBYD137Heavy Duty Copper Terminal Long Barrel.16/25 Sqmm Copper Terminal, Apprx Wt: 11 Gm. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo27.027.0128.0FalseNoneNoneFalseNoneFalse3456.00
243660973308NoneBYD138Heavy Duty Copper Terminal Long Barrel.185 Sqmm Copper Terminal, Apprx Wt: 158 Gm. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo274.0274.080.0FalseNoneNoneFalseNoneFalse21920.00
243661073308NoneBYD139Brass Cable Gland 25mm. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo79.079.016.0FalseNoneNoneFalseNoneFalse1264.00
243661173308NoneBYD140Brass Cable Gland 40mm. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo148.0148.020.0FalseNoneNoneFalseNoneFalse2960.00
243661273308NoneBYD141Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr (BESCOM SR PART-4,P.NO.8, IT No-29.02) Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour tools, usage& other appurtenances required to complete the work. with all leads and lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workCum484.0484.0127.5FalseNoneNoneFalseNoneFalse61710.00
243661373308NoneBYD142Refilling the cable trenches with selected available earth from trench excavation including watering, consolidation in layers of 15 cm. Thickness including depositing of the surplus earth with a lead of 200 Mtr with all leads and lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workCum58.058.0127.5FalseNoneNoneFalseNoneFalse7395.00
243661473308NoneBYD143Supply of DP Structure using RCC Pole - 9 Mtr Long, 145 Kg WL (Including Cost of Poles) with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workSet20928.020928.02.0FalseNoneNoneFalseNoneFalse41856.00
243661573308NoneBYD144fixing of DP Structure using RCC Pole - 9 Mtr Long, 145 Kg WL (Including Cost of Poles) with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workSet5372.05372.02.0FalseNoneNoneFalseNoneFalse10744.00
243661673308NoneBYD145Supply of 11 kV, 45 KN Polymeric Insulator. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo186.0186.012.0FalseNoneNoneFalseNoneFalse2232.00
243661773308NoneBYD146Supply of Guy Set Complete with No. 15 Strain Insulator & Concreting materials.Supply of Guy Clamp - GI. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo115.0115.04.0FalseNoneNoneFalseNoneFalse460.00
243661873308NoneBYD147Supply of Turn Buckle (GI)(Dwg No. BESCOM/GM/QS&S/07 Dtd 24.11.2018). with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo241.0241.04.0FalseNoneNoneFalseNoneFalse964.00
243661973308NoneBYD148Supply of Anchor Rod using 12 mm rounds/Guy Rod - GI. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo329.0329.04.0FalseNoneNoneFalseNoneFalse1316.00
243662073308NoneBYD149Supply of No. 15 Strain Insulator. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo59.059.04.0FalseNoneNoneFalseNoneFalse236.00
243662173308NoneBYD150Supply of Guy Wire & GI Wire as per IS-2141.7/10 SWG Guy Wire(7/3.251 mm Dia), Std Wt: 680 Kg/KM. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workMT77226.077226.00.01FalseNoneNoneFalseNoneFalse772.260
243662273308NoneBYD151Digging of Pit for GUY SET.Ordinary Soil. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workPer Pit327.0327.04.0FalseNoneNoneFalseNoneFalse1308.00
243662373308NoneBYD152Fixing of GUY Set with break insulator making use of 7/3.15 mm (7/10 SWG) galvanised steel wire with turn buckle and anchoring arrangement as per approved drawing. (Excluding excavation of PIT) with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workPer Set266.0266.04.0FalseNoneNoneFalseNoneFalse1064.00
243662473308NoneBYD153supply of Spiral Earth Electrode. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo239.0239.04.0FalseNoneNoneFalseNoneFalse956.00
243662573308NoneBYD154Providing Spiral Earth Electrode type earthing. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo93.093.04.0FalseNoneNoneFalseNoneFalse372.00
243662673308NoneBYD155Supply of Caution/Danger Board. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo150.0150.02.0FalseNoneNoneFalseNoneFalse300.00
243662773308NoneBYD156fixing of Caution/Danger Board. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo80.080.02.0FalseNoneNoneFalseNoneFalse160.00
243662873308NoneBYD157Supply of Anti Climbing Device (12 Mtr GI Barbed Wire). with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workEach89.089.04.0FalseNoneNoneFalseNoneFalse356.00
243662973308NoneBYD158fixing of Anti Climbing Device (12 Mtr GI Barbed Wire). with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workEach42.042.04.0FalseNoneNoneFalseNoneFalse168.00
243663073308NoneBYD159Supply of 11 kV, 400 Amps Double Break GOS(Dwg No. BESCOM/GM/QS&S/22 Dtd 24.11.2018). with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workSet21260.021260.02.0FalseNoneNoneFalseNoneFalse42520.00
243663173308NoneBYD160Fixing of GOS including wiring (11 kV Double Break 400 Amps). with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workSet1214.01214.02.0FalseNoneNoneFalseNoneFalse2428.00
243663273308NoneBYD161Supply of Single H Frame without Transformer Seating and Seating angle support cross arm for 11 Mtr Spun Pole for 63/100/250/500kVA (OH Line) GI. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo17987.017987.02.0FalseNoneNoneFalseNoneFalse35974.00
243663373308NoneBYD162Erection of H-Frame.for mounting GOS. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo323.0323.02.0FalseNoneNoneFalseNoneFalse646.00
243663473308NoneBYD163Supply of 11 kV, DOLO Cutout Conventional to Erstwhile KEB Specification.with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workSet5875.05875.02.0FalseNoneNoneFalseNoneFalse11750.00
243663573308NoneBYD164Fixing DOLO Cutout/Horn Gap Fuse including fixing of cross arm and wiring. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workSet237.0237.02.0FalseNoneNoneFalseNoneFalse474.00
243663673308NoneBYD165Supply of 11 kV [6.35/11 kV(E)], HT Aerial Bunched Cable XLPE insulation confirming to IS-14255: 1995 3x95 + 1x70 Sqmm (Insulated Messenger Wire). with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workKm959730.0959730.00.04FalseNoneNoneFalseNoneFalse38389.20
243663773308NoneBYD166Stringing of 11 kV grade Aerial Bunched 3 Core cable of XLPE insulation of size 3x95 Sqmm + 1x70 Sqmm with Insulated Messenger Wire. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workKm34765.034765.00.04FalseNoneNoneFalseNoneFalse1390.60
243663873308NoneBYD167Supply of 11 kV, AB Cable Straight thru' joint kit suitable for 95 Sqmm. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workSet7685.07685.02.0FalseNoneNoneFalseNoneFalse15370.00
243663973308NoneBYD168Laying of 11 kV AB Cable Straight thru' joint installation for 3 Core. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workSet1424.01424.02.0FalseNoneNoneFalseNoneFalse2848.00
243664073308NoneBYD169Supply of 11 kV, ABC Termination kit 95 -120 Sqmm. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workSet2856.02856.02.0FalseNoneNoneFalseNoneFalse5712.00
243664173308NoneBYD170Laying of 11 kV AB Cable Termination installation for 3 Core. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workSet1139.01139.02.0FalseNoneNoneFalseNoneFalse2278.00
243664273308NoneBYD171Supply of Suspension Clamp Assembly 70 to 210 Sqmm Bare Messenger (Exclusive of Pole Clamp and Eye Hook). with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workSet355.0355.02.0FalseNoneNoneFalseNoneFalse710.00
243664373308NoneBYD172Laying of Erection of Suspension Clamp - 25 to 95 Sqmm bare/Insulated messenger. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workSet96.096.02.0FalseNoneNoneFalseNoneFalse192.00
243664473308NoneBYD173Supply of Pole Clamp for HT/LT AB cable.. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workSet109.0109.02.0FalseNoneNoneFalseNoneFalse218.00
243664573308NoneBYD174Fixing of Pole Clamp-145 mm x 95 with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workSet160.0160.02.0FalseNoneNoneFalseNoneFalse320.00
243664673308NoneBYD175Supply of 11 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975. 95 Sqmm, (54 GI Wires - 2.5 mm Dia). with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workKm889666.0889666.00.12FalseNoneNoneFalseNoneFalse106759.920
243664773308NoneBYD176Supply of Heat Shrinkable Indoor Type Cable Termination Kit for XLPE Cable.3Cx95sqmm indoor. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workKit3744.03744.03.0FalseNoneNoneFalseNoneFalse11232.00
243664873308NoneBYD177Supply of Heat Shrinkable Outdoor Type Cable Termination Kit for XLPE Cable 3Cx95sqmm outdoor. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workKit4067.04067.03.0FalseNoneNoneFalseNoneFalse12201.00
243664973308NoneBYD178Supply of Cable covering tiles 250x125x40mm.. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo10.2510.2550.0FalseNoneNoneFalseNoneFalse512.50
243665073308NoneBYD179Supply of River sand. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workCum1476.01476.05.0FalseNoneNoneFalseNoneFalse7380.00
243665173308NoneBYD180Supply of RCC humepipes 2000mm long 150mm dia. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo307.0307.04.0FalseNoneNoneFalseNoneFalse1228.00
243665273308NoneBYD181Supply of Collars for RCC hume pipes. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo82.082.04.0FalseNoneNoneFalseNoneFalse328.00
243665373308NoneBYD182Supply of GI pipe 150mm dia. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workMtr1021.01021.020.0FalseNoneNoneFalseNoneFalse20420.00
243665473308NoneBYD183Supply of Route and Joint indicating stones with MS Anchor rod. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo133.0133.020.0FalseNoneNoneFalseNoneFalse2660.00
243665573308NoneBYD184Earth work excavation for cable treanch of 0.5 to 0.75Mtr Width and Depth up to 1Mtr .BESCOM SR PART-4,PAGE-8,ITEAM NO-29.02 -Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering including cost of labour, tools, usage& other appurtenances required to complete the work. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workCum484.0484.040.0FalseNoneNoneFalseNoneFalse19360.00
243665673308NoneBYD185Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff.3x95 to 150 Sqmm. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workKm61322.061322.00.12FalseNoneNoneFalseNoneFalse7358.640
243665773308NoneBYD186Retailing the cable trenches with selected availble earth from trench excavation including watering,Consolidation in layers of 15Cm thickness including depositing of the surplus earth with a lead of 200Mtrs. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workCum58.058.040.0FalseNoneNoneFalseNoneFalse2320.00
243665873308NoneBYD187Making and Fixing pot head for HT Cable only.Heat shrinkable Type Terminations.3x95 to 3x150 Sqmm with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form work.No2658.02658.06.0FalseNoneNoneFalseNoneFalse15948.00
243665973308NoneBYD188Covering the cables with tiles. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workKm4367.04367.00.1FalseNoneNoneFalseNoneFalse436.70
243666073308NoneBYD189Spreading and forming with sand alround the cable to a depth of 75mm and width of 500mm . with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workKm14810.014810.00.1FalseNoneNoneFalseNoneFalse1481.00
243666173308NoneBYD190Laying and Jointing the pipes (100-150 mm Dia) incl with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workuding lowering in Position: Fixing Collars etc., Joining with mud mortor complete.RCC Pipe..Mtr69.069.06.0FalseNoneNoneFalseNoneFalse414.00
243666273308NoneBYD191Laying the GI Pipe 80 mm to 150 mm dia at Drainage Water Supply Crossing including fixing collars elbows, bends, Tees and other fitting with Cuts and Threads wherever necessary complete.. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workMtr93.093.020.0FalseNoneNoneFalseNoneFalse1860.00
243666373308NoneBYD192Fixing of Route Joint Indicating Slab.. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo116.0116.020.0FalseNoneNoneFalseNoneFalse2320.00
243666473308NoneBYD19311kV HT Metering cubical of different CT Ratio Both side entry type with 3CT & 3PTs with transparent cover TTB,with 30x8mm Copper Bus bars,modem and 2nos of Meters for 3 Phase 4 Wire Metering WITHOUT Load break Switch (HT Metering Box Fabricated out of 3mm MS Sheet duly epoxy powder coated)as per revised specification.Dwg No. BESCOM/GM/QS&S/ Dtd 24.11.2018) with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo243472.0243472.01.0FalseNoneNoneFalseNoneFalse243472.00
243666573308NoneBYD194Load Break switches with Panel. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo73239.073239.01.0FalseNoneNoneFalseNoneFalse73239.00
243666673308NoneBYD195Erection of HT metering Cubicle on Platform. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo1844.01844.01.0FalseNoneNoneFalseNoneFalse1844.00
243666773308NoneBYD196Erection Alignment and fixing of Load break switch on the platform. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo2078.02078.01.0FalseNoneNoneFalseNoneFalse2078.00
243666873308NoneBYD197Construction of platform (1.5x1.5x1.2) mtr in size stone,cement concrete for erection of Metering cubical,Transformer and Load break switch: Excavation of (1.5x1.5x1) mt pit for foundation providing and laying cement concrete 1:4:8 for foundation laid in 10cm thick layers, well compacted curing etc., complete providing and construction of stone masonary 0.9m below ground level and 1.2m above ground level neatly hammer dressed in cement morter 1:6. Providing cement concrete Slab(1.5x1.5x0.10)Mtr with cement concrete 1:2:4 mix forming and cutting complete providing pointing to stone masonary in cement morter 1:3 after racking joint & nisely lining curing etc., plastering the concrete surfaces in cement morter 1:4 including smooth randering curing etc., curing at every stages completely with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo21757.021757.03.0FalseNoneNoneFalseNoneFalse65271.00
243666973308NoneBYD198Distribution Transformer - 3 Phase, 11kV/433V - Stacked CRGO Core with Oil as per IS-1180 (Part-1) 2014.21. 500 kVA, Aluminium Wdg, Star 2 (5 Star). with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo913779.0913779.01.0FalseNoneNoneFalseNoneFalse913779.00
243667073308NoneBYD199Erection of 300 - 500 kVA Transformer. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo3085.03085.01.0FalseNoneNoneFalseNoneFalse3085.00
243667173308NoneBYD200Providing chain link fencing 50mm size of 8 guage properly stretched between rectangular poles and fixed with suitable bolts & nuts, the free ends shall be welded to the pole and block pipe at top and bottom as required including cost of all materials, labour, lead and lifts, cutting, bending wherever necessary, wastage and lapping etc., complete as per the direction of the engineer incharge for work including two coats of approved quality paint over one coat of primer paint. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workSqm249093.0249093.01.0FalseNoneNoneFalseNoneFalse249093.00
243667273308NoneBYD201Supplying,fixing,wiring,earth electrode for grounding conduits,I.C.cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5m long buried in a pit.The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth.The connection from the pipe to the conduit etc.,is tobe established through GI wire of size as per lSI specification 7.3.3.of IS732 using 12 mm dia bolts,nuts,washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo3510.03510.06.0FalseNoneNoneFalseNoneFalse21060.00
243667373308NoneBYD202Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNo4256.04256.010.0FalseNoneNoneFalseNoneFalse42560.00
243667473308NoneBYD203Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. GI strip GI Strip. 25x3mm with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workMtr82.082.060.0FalseNoneNoneFalseNoneFalse4920.00
243667573308NoneBYD204Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. GI strip 50x6mm GI strip with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workMtr218.0218.030.0FalseNoneNoneFalseNoneFalse6540.00
243667673308NoneBYD205Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25 x 3 mm Copper strip with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workMtr570.0570.020.0FalseNoneNoneFalseNoneFalse11400.00
243667773308NoneBYD206Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25 x 6 mm Copper strip with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workMtr1100.01100.020.0FalseNoneNoneFalseNoneFalse22000.00
243667873308NoneBYD207Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required.600 x 600 x 3 mm Copper platewith all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workMtr7421.07421.06.0FalseNoneNoneFalseNoneFalse44526.00
243667973308NoneBYD208Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG. Copper Wire with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workMtr58.058.050.0FalseNoneNoneFalseNoneFalse2900.00
243668073308NoneBYD209Supplying of four bucket stand along with buckets. Complete. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workEach1850.01850.01.0FalseNoneNoneFalseNoneFalse1850.00
243668173308NoneBYD210Supplying of Hand gloves. Complete. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workEach975.0975.02.0FalseNoneNoneFalseNoneFalse1950.00
243668273308NoneBYD211Supplying of first aid box. Complete.. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workEach600.0600.01.0FalseNoneNoneFalseNoneFalse600.00
243668373308NoneBYD212Supplying of SAFETY MASK. Complete. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workEach150.0150.02.0FalseNoneNoneFalseNoneFalse300.00
243668473308NoneBYD213Supplying of FIRST AID CHART with lamination.Complete . with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workEach400.0400.01.0FalseNoneNoneFalseNoneFalse400.00
243668573308NoneBYD214Supplying and installation of RUBBER MAT 1mtrx1mtr-1Omm thick.complete including cost of materials,labour,usage charges of machinery complete as per specifications. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workEach1900.01900.01.0FalseNoneNoneFalseNoneFalse1900.00
243668673308NoneBYD215Providing and Fixing evacuation plan of size A3 made out to Acrylic sheet of 3mm thick and fixing with Stainless Steel finished studs etc.complete including cost of materials,labour,usage charges of machinery complete as per specifications. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workSq CM6500.06500.02.0FalseNoneNoneFalseNoneFalse13000.00
243668773308NoneBYD216Solar Photovoltaic Power PlantSupply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required a) Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. c) Data Monitoring System complete with accessories. d) Fixing of Array junction box Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. e) Lightning and surge voltage protection. f) Connections & Interconnections by required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables btw solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workKilo Watt61060.061060.020.0FalseNoneNoneFalseNoneFalse1221200.00
243668873308NoneBYD217Supplying, installing, testing and commissioning of PRIME Diesel Generator set with following specifications. Power rating as per standard reference condition as perBS 5514 / ISO 3046 / ISO 8528 & IS 1002 / ISO 3046 Generator set specifications.Engine Diesel generating set are rated at 1500RPM and conform to ISO 8528 specifications. The engines are radiator cooled, four stroke and multi cylinder, conforming to ISO 3046. The scope of supply includes: Electrical starter motor 12V DC Battery charging alternator, Bosch fuel system with mechanical governor, A1 Class. Spin-on lube oil filter, Spin-on dual fuel filter with water separator, Turbocharger, Charge air cooler, Silencer (Hospital grade),Dry type air cleaner, Shutoff coil, Flywheel and flywheel housing, First fill of lube oil and coolant, Safety for low lube oil pressure, Safety for high water temperature, Permissible overload of 10% for one hour in 12 hours of operation.Capacity of Fuel Tank: Fuel tank suitable for 8 hours of operation.Mounting arrangement: Engine and alternator are mounted on a common MS fabricated base frame with AVM pads.Control Panel: The control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish. The control panel consists of the following parts PS0500 Controller, MCCB of suitable rating with overload and shor processor based generator set monitoring and control system. The control provides a simple operator interface to the generator set, manual and remote start/ stop control, shutdown fault indication, and an LCD hour counter. The integration of all functions into a single control system provides enhanced reliability and performance compared to conventional generator set control systems. This control has been designed and tested to meet harsh environment in which gensets are typically applied. Features, Functions, protections 16 character x 2 line alphanumeric LCD display with LED Backlight.Operator interface, Provide a record of most recent fault conditions. Fault history stored in the control non volatile memory, Provide Alternator Data. Voltage (1 ph or 3 ph line to line and line to neutral voltage, Current (1 ph or 3 ph) kVA (3 ph and total), Frequency, Provide Engine Data, Starting battery voltage, Engine running hours, Engine Temp, Engine oil pressure, Control includes provision for Service adjustment and calibration of DG control functions, Voltage, frequency selection, Configurable input and output set up, Meter calibration, Engine controls, Power Start operates on 12 VDC batteries Auto start mode accepts a ground signal from remote devices to automatically start the DG set. The remote start will also wake up the control system from sleep mode.Acoustic enclosure: The acoustic enclosure shall be made of 1.6 mm thick CRCA sheets in suitable approved shade and a structural/ sheet metal base frame painted in black. The walls of the enclosure are insulated with fire retardant foam so as to comply with the 75dBA at 1 mtr sound levels specified by Ministry of Environment & Forest. The enclosure has the following features: Specially designed to meet stringent MOEF/ CPCB norms of 75dBA at 1mtr at 75% load under free field conditions, Two point lifting for easy handling at customer site, Designed to have optimum serviceability, Air inlet louvers specially designed to operate at rated load made on special purpose CNC machines for consistency in quality and workmanship, Powder coated for lasting service life and superior finish, With UV resistant powder coating, can withstand extreme environment,Use of special hardware for longer life, Insulation material meets exacting IS 8183 better sound attenuation, Flush styling - no projections, Fluid drains for lube oil and fuel, Fuel filling point inside the enclosure.320 KVA / 256 kw with all leads and lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workSet2644841.02644841.01.0FalseNoneNoneFalseNoneFalse2644841.00
243668973308NoneBYD218Supply, erection, testing & commissioning of electrical motor driven end suction back pull out centrifugal pump capable of delivering,adequate 2280 LPM and 70m head at required head. when running at 2900 rpm directly coupled to TEFC electrical motor of adequate HP to operate on 400/440 V 3 phase, 50 cycles AC supply with required foundation for pump, a terminal box suitable for reception, common bed plate with necessary anti vibration pads, necessary foundation bolts and accessories,neoprine gaskets (16 kg/sq.cm) Control panel is excluded.Required GA drawing for the pump/ foundation shall be submitted by the contractor. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the workNos.285000.0285000.01.0FalseNoneNoneFalseNoneFalse285000.00
243669073308NoneBYD219Supply, erection, testing and commissioning of Fire Fighting panel cubicle type made out of 14/16 Swg MS CRCA sheet which is derusted, degreased, phosphated and passivated with angle iron skeleton or sheet folded construction. The panel to be dust and vermin proof type and with powder coated paint after suitable seven tank pretreatment. The panel will have individual compartments for incoming and outgoing feeders made out of cold rolled sheet and doors fitted with Neoprene gaskets and fasteners. The switchboards are to be tested as per IS 8623-1977 specifications. Busbars are to be of high conductivity Aluminium Alloy E91E IS 5082 specification. The panel shall have both bottom & top cable entry provisions and panel shall be mounted on Pedestal of 300 mm height with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the workNo278000.0278000.01.0FalseNoneNoneFalseNoneFalse278000.00
243669173308NoneBYD220Supplying, laying, testing & commissioning of FRLS,PVC outer sheateh, steel armoured, aluminium / copper conductor, 1100v grade power cables with glands etc.The cables shall be laid in tray /on walls/ floor etc. as required. For cables laid In door the rate shall include. The rate shall be include with cable terminations with Al. / Cu. lugs, cable glands, PVC insulation tapes and all other accessories as required. 3.5C x 120 sq.mm for main pumps (Al) with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the workMtr456.8456.810.0FalseNoneNoneFalseNoneFalse4568.00
243669273308NoneBYD221Supplying, laying, testing & commissioning of FRLS,PVC outer sheateh, steel armoured, aluminium / copper conductor, 1100v grade power cables with glands etc.The cables shall be laid in tray /on walls/ floor etc. as required. For cables laid In door the rate shall include. The rate shall be include with cable terminations with Al. / Cu. lugs, cable glands, PVC insulation tapes and all other accessories as required. 3.5C x 95 sq.mm for main pumps (Al) with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the workMtr373.21373.2110.0FalseNoneNoneFalseNoneFalse3732.10
243669373308NoneBYD222Supplying, laying, testing & commissioning of FRLS,PVC outer sheateh, steel armoured, aluminium / copper conductor, 1100v grade power cables with glands etc.The cables shall be laid in tray /on walls/ floor etc. as required. For cables laid In door the rate shall include. The rate shall be include with cable terminations with Al. / Cu. lugs, cable glands, PVC insulation tapes and all other accessories as required. 2 C x 2.5 Sqmm.for Instrumentation (Cu) with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the workMtr62.1662.165.0FalseNoneNoneFalseNoneFalse310.80
243669473308NoneBYD223Supply, Installation testing and commissioning of approved make heavy tubes (Class 'C') confirming to as per IS1239 Part- I (25mm Nominal bore 4.05mm thick@ 2.97 Kg/m, 32mm Nominal bore 4.05mm thick @ 3.84 Kg/m,40mm Nominal bore 4.05mm thick@ 4.43 Kg/m,50mm Nominal bore 4.47mm thick@ 6.17 Kg/m, 65mm Nominal bore 4.47mm thick @ 7.90 Kg/m, 80mm Nominal bore 4.85mm thick @ 10.10 Kg/m, 100mm Nominal bore 5.40mm thick@ 14.40 Kg/m,150mm Nominal bore, 5.40mm thick @ 21.20 Kg/m, Such as Tees elbows check nuts unions, Flanger, Nipples etc. including cutting welding, Trending fixing on walls, ceiling (Using 41- Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. including cost of materials, labour, usage charges of machinery complete as per specifications. Wraping and Galing of U/G pipe line work includes one coat of anti corrossion paint (Black) and two coats of Bituminous cloth. including cost of materials, labour, usage charges of machinery complete as per specifications. 250mm nominal dia with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the workMtr4900.04900.05.0FalseNoneNoneFalseNoneFalse24500.00
243669573308NoneBYD224Supply, Installation testing and commissioning of approved make heavy tubes (Class 'C') confirming to as per IS1239 Part- I (25mm Nominal bore 4.05mm thick@ 2.97 Kg/m, 32mm Nominal bore 4.05mm thick @ 3.84 Kg/m,40mm Nominal bore 4.05mm thick@ 4.43 Kg/m,50mm Nominal bore 4.47mm thick@ 6.17 Kg/m, 65mm Nominal bore 4.47mm thick @ 7.90 Kg/m, 80mm Nominal bore 4.85mm thick @ 10.10 Kg/m, 100mm Nominal bore 5.40mm thick@ 14.40 Kg/m,150mm Nominal bore, 5.40mm thick @ 21.20 Kg/m, Such as Tees elbows check nuts unions, Flanger, Nipples etc. including cutting welding, Trending fixing on walls, ceiling (Using 41- Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. including cost of materials, labour, usage charges of machinery complete as per specifications. Wraping and Galing of U/G pipe line work includes one coat of anti corrossion paint (Black) and two coats of Bituminous cloth. including cost of materials, labour, usage charges of machinery complete as per specifications. 200mm nominal dia with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the workMtr4300.04300.05.0FalseNoneNoneFalseNoneFalse21500.00
243669673308NoneBYD225Supply, Installation testing and commissioning of approved make heavy tubes (Class C) confirming to as per IS1239 Part- I (25mm Nominal bore 4.05mm thick at 2.97 Kg/m,32mm Nominal bore 4.05mm thick at 3.84 Kg/m, 40mm Nominal bore 4.05mm thick at 4.43 Kg/m,50mm Nominal bore 4.47mm thickat 6.17 Kg/m, 65mm Nominal bore 4.47mm thick at 7.90 Kg/m, 80mm Nominal bore 4.85mm thick at 10.10 Kg/m, 100mm Nominal bore 5.40mm thick at 14.40 Kg/m,150mm Nominal bore, 5.40mm thick at 21.20 Kg/m, Such as Tees elbows check nuts unions, Flanger, Nipples etc. including cutting welding, Trending fixing on walls, ceiling (Using 41- Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. including cost of materials, labour, usage charges of machinery complete as per specifications. 150mm nominal dia with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the workMtr3900.03900.05.0FalseNoneNoneFalseNoneFalse19500.00
243669773308NoneBYD226Supply, Installation testing and commissioning of approved make heavy tubes (Class C) confirming to as per IS1239 Part- I (25mm Nominal bore 4.05mm thick at2.97 Kg/m,32mm Nominal bore 4.05mm thick at 3.84 Kg/m, 40mm Nominal bore 4.05mm thick at4.43 Kg/m,50mm Nominal bore 4.47mm thick at 6.17 Kg/m, 65mm Nominal bore 4.47mm thick at 7.90 Kg/m, 80mm Nominal bore 4.85mm thick at 10.10 Kg/m, 100mm Nominal bore 5.40mm thickat 14.40 Kg/m,150mm Nominal bore, 5.40mm thick at 21.20 Kg/m, Such as Tees elbows check nuts unions, Flanger, Nipples etc. including cutting welding, Trending fixing on walls, ceiling (Using 41- Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. including cost of materials, labour, usage charges of machinery complete as per specifications. 25mm nominal dia with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the workMtr700.0700.05.0FalseNoneNoneFalseNoneFalse3500.00
243669873308NoneBYD227Supplying installing, testing and commissioning of PN16 CI Non Return Valve confirming to IS 13039 with necessary bolts and nuts etc complete includes cost of all materials labour charges with all lead lift loading andunloading transportation etc complete. etc complete as per specificaitonwith all lead and lift, loading unloading, labour, hire charges of machineriesand all such incidental charges necessary for successful completion of workand as per directions of the Engineer-in-charge of the work 150 mm nominal dia with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the workNos11500.011500.01.0FalseNoneNoneFalseNoneFalse11500.00
243669973308NoneBYD228Supplying, installing , testing and commissioning of PN16 CI butterfly valves of confirming to IS 13039 with necessary nuts & bolts etc.,complete etc complete as per specificaiton with all lead and lift, loading unloading, labour,hire charges of machineries and all such incidental charges necessary forsuccessful completion of work and as per directions of the Engineer-in-chargeof the work 150mm nominal dia with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the workNos12500.012500.01.0FalseNoneNoneFalseNoneFalse12500.00
243670073308NoneBYD229supply and installing testing and commissioning of CI Y stainer confirming to IS standard with necessary bolts and nuts complete includes cost of all materials labour charges with all lead lift loading and unloading transportation etc complete. etc complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such in cidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work 250mm dia. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the workNos24500.024500.01.0FalseNoneNoneFalseNoneFalse24500.00
243670173308NoneBYD230Supplying, installing , testing and commissioning approved make CI Gate valves as per IS 780 / 14846 with flanges, bolts, nuts, washers, gaskets etc. complete etc complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work 250mm nominal dia with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the workNos39688.039688.01.0FalseNoneNoneFalseNoneFalse39688.00
243670273308NoneBYD231Supplying Installing, testing and commissioning of Gun metal BALL VALVE SIZE OF 25mm dia including cost of materials, labour, usage charges of machinery complete as per specifications. Complete 15mm dia. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the workNos950.0950.01.0FalseNoneNoneFalseNoneFalse950.00
243670373308NoneBYD232Supplying Installing, testing and commissioning of Gun metal BALL VALVE SIZE OF 25mm dia including cost of materials, labour, usage charges of machinery complete as per specifications. Complete 25 mm dia with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the workNos1200.01200.01.0FalseNoneNoneFalseNoneFalse1200.00
243670473308NoneBYD233Pressure Switch including Isolation Valve and forged siphon Tube including with all accssories as per IS:Spec. etc complete as per specificaiton with all lead and lift, loadi g unloading, labour, hire charges of machineries and all such incidental charges necessary for successful comp with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the workSet1950.01950.01.0FalseNoneNoneFalseNoneFalse1950.00
243670573308NoneBYD234Pressure guage of 150 mm dia including Isolation Valve and forged siphon Tube including with all accssories as per IS:Spec. etc complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the workSet2900.02900.01.0FalseNoneNoneFalseNoneFalse2900.00
243670673308NoneBYD235Supply, Installation testing and commissioning of approved make heavy tubes (Class C) confirming to as per IS1239 Part- I (25mm Nominal bore 4.05mm thick@ 2.97 Kg/m, 32mm Nominal bore 4.05mm thick at 3.84 Kg/m, 40mm Nominal bore 4.05mm thick@ 4.43 Kg/m,50mm Nominal bore 4.47mm thick at 6.17 Kg/m, 65mm Nominal bore 4.47mm thick @ 7.90 Kg/m, 80mm Nominal bore 4.85mm thick at 10.10 Kg/m, 100mm Nominal bore 5.40mm thick@ 14.40 Kg/m,150mm Nominal bore, 5.40mm thick at 21.20 Kg/m,Such as Tees elbows check nuts unions, Flanger, Nipples etc. includingcutting welding, Trending fixing on walls, ceiling (Using 41- Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. including cost of materials, labour, usage charges of machinery complete as per specifications. specifications. 150mm nominal dia with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the workMtr3900.03900.014.0FalseNoneNoneFalseNoneFalse54600.00
243670773308NoneBYD236Supply, Installation testing and commissioning of approved make heavy tubes (Class C) confirming to as per IS1239 Part- I (25mm Nominal bore 4.05mm thick at 2.97 Kg/m, 32mm Nominal bore 4.05mm thick at 3.84 Kg/m, 40mm Nominal bore 4.05mm thick at 4.43 Kg/m,50mm Nominal bore 4.47mm thick at 6.17 Kg/m, 65mm Nominal bore 4.47mm thick at 7.90 Kg/m, 80mm Nominal bore 4.85mm thick at 10.10 Kg/m, 100mm Nominal bore 5.40mm thick at 14.40 Kg/m,150mm Nominal bore, 5.40mm thick at 21.20 Kg/m,Such as Tees elbows check nuts unions, Flanger, Nipples etc. includingcutting welding, Trending fixing on walls, ceiling (Using 41- Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. including cost of materials, labour, usage charges of machinery complete as per specifications. specifications. 25mm nominal dia with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the workMtr700.0700.015.0FalseNoneNoneFalseNoneFalse10500.00
243670873308NoneBYD237200mm nominal dia Supply, Installation testing and commissioning of approved make heavy tubes (Class C) confirming to as per IS1239 Part- I (25mm Nominal bore 4.05mm thick at 2.97 Kg/m,32mm Nominal bore 4.05mm thick at 3.84 Kg/m, 40mm Nominal bore 4.05mm thick at4.43 Kg/m,50mm Nominal bore 4.47mm thick at 6.17 Kg/m, 65mm Nominal bore 4.47mm thick at 7.90 Kg/m,80mm Nominal bore 4.85mm thick at 10.10 Kg/m, 100mm Nominal bore 5.40mm thick at 14.40 Kg/m,150mm Nominal bore, 5.40mm thick at 21.20 Kg/m,Such as Tees elbows check nuts unions, Flanger, Nipples etc. including cutting welding, Trending fixing on walls, ceiling (Using 41- Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. including cost of materials, labour, usage charges of machinery complete as per specifications. Wraping and Galing of U/G pipe line work includes one coat of anti corrossion paint (Black) and two coats of Bituminous cloth. including cost of materials, labour, usage charges of machinery complete as per specifications. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the workMtr4300.04300.010.0FalseNoneNoneFalseNoneFalse43000.00
243670973308NoneBYD238Supply, Installation testing and commissioning of approved make heavy tubes (Class C) confirming to as per IS1239 Part- I (25mm Nominal bore 4.05mm thickat 2.97 Kg/m,32mm Nominal bore 4.05mm thick at 3.84 Kg/m, 40mm Nominal bore 4.05mm thick at 4.43 Kg/m,50mm Nominal bore 4.47mm thickat 6.17 Kg/m, 65mm Nominal bore 4.47mm thick at 7.90 Kg/m,80mm Nominal bore 4.85mm thick at 10.10 Kg/m, 100mm Nominal bore 5.40mm thickat 14.40 Kg/m,150mm Nominal bore, 5.40mm thick at 21.20 Kg/m,Such as Tees elbows check nuts unions, Flanger, Nipples etc. including cutting welding, Trending fixing on walls, ceiling (Using 41- Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. including cost of materials, labour, usage charges of machinery complete as per specifications. Wraping and Galing of U/G pipe line work includes one coat of anti corrossion paint (Black) and two coats of Bituminous cloth. including cost of materials, labour, usage charges of machinery complete as per specifications. 80mm nominal dia with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the workMtr2300.02300.020.0FalseNoneNoneFalseNoneFalse46000.00
243671073308NoneBYD239Supplying, installing , testing and commissioning of PN16 CI butterfly valves of confirming to IS 13039 with necessary nuts & bolts etc., complete etc complete as per specificaiton with all lead and lift, loading unloading, labour,hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work 150mm nominal dia (For Risers) with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the workNos12500.012500.02.0FalseNoneNoneFalseNoneFalse25000.00
243671173308NoneBYD240Supplying Installing, testing and commissioning of 63mm mm dia single headed Gun mental Hydrant Valve with flanged inlet, stop valve, spindle and cast iron hand wheel. It has a female instantaneous outlet with Blank Cap and is Hydrostatically tested to 21Kgf/cm2 pressure having a flow rate of 900 LPM at 7 Kgf/cm 2 of pressure with blank cap and wheel as per IS 5290 etc. complete including cost of materials, labour, usage charges of machinery complete as per specifications. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the workNos.10500.010500.04.0FalseNoneNoneFalseNoneFalse42000.00
243671273308NoneBYD241Supplying Installing, testing and commissioning of Reinforced Rubber Lined 2nos .RRL Fire hose of 63mm dia 15m length as per IS 8423 binded with one set of male and Female lnstantainious Gun metal coupling as per IS 903 complete including cost of materials, labour, usage charges of machinery complete as per specifications. with all leads and lifts complete as per specification anf as direted by the Engineer incharge of the workNos5000.05000.04.0FalseNoneNoneFalseNoneFalse20000.00
243671373308NoneBYD242Supplying Installing, testing and commissioning of Gun metal Branch pipe size of 63mm dia x19mm dia as per IS 903 complete including cost of materials, labour, usage charges of machinery complete as per specifications. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the workNos4500.04500.04.0FalseNoneNoneFalseNoneFalse18000.00
243671473308NoneBYD243Supplying Installing, of M.S. Pressed reel of 600mm dia swinging type motion which allows a 180swing and conforms to IS:884/85 or Aluminium fitting Single Piece Compact Type. including cost of materials, labour, usage charges of machinery complete as per specifications. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the workNos5200.05200.04.0FalseNoneNoneFalseNoneFalse20800.00
243671573308NoneBYD244Supplying Installing, testing and commissioning of 19mm dia 40.0m length hose with rubber lining smooth bore, reinforced of natural/synthetic fibres, a rubber cover finish shall be smooth, fluted or fabric marked with minimum thickness of 1.50mm and to with stand a working pressure of 10Kgf/sqcm confirms & tested as per IS 444/ IS 12585 including cost of materials, labour, usage charges of machinery complete as per specifications. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the workNos6000.06000.04.0FalseNoneNoneFalseNoneFalse24000.00
243671673308NoneBYD245Supplying Installing, testing and commissioning of Hose cabinet made out of 18 gauge M.S.sheet with double glass door with lacing arrangement and painted with two coats of Fire red Enamel paint at outer ise of the Box and two coats of white enamel paint at inner side of the box is to accomodate 2 Nos. of Fire hose box size 20x24x10 complete including cost of materials, labour, usage charges of machinery complete as per specifications. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the workNos6500.06500.06.0FalseNoneNoneFalseNoneFalse39000.00
243671773308NoneBYD246Supplying Installing, testing and commissioning of 100mm dia 2 way Fire brigade inlet connection of 2 nos. 63 mm dia. including cost of materials, labour, usage charges of machinery complete as per specifications. with all leads and lifts complete as per specification anf as direted by the Engineer incharge of the workNos33000.033000.01.0FalseNoneNoneFalseNoneFalse33000.00
243671873308NoneBYD247Supplying Installing, testing and commissioning of Gun metal AIR RELEASE VALVE SIZE OF 25mm dia including cost of materials, labour,usage charges of machinerywith all leads & lifts complete as per specification anf as direted by the Engineer incharge of the workNos1500.01500.02.0FalseNoneNoneFalseNoneFalse3000.00
243671973308NoneBYD248Supplying Installing, testing and commissioning of Gun metal BALL VALVE SIZE OF 25mm dia including cost of materials, labour, usage charges of machinery with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work 25mm dia.Nos1200.01200.02.0FalseNoneNoneFalseNoneFalse2400.00
243672073308NoneBYD249Green mist Extinguishers Supply and installation of 6 Ltr Watermist technology base, Stored pressure type, Rating 8A. 34B & 40F, Mild steel body t, Tamper- proof safety seal, Effective on Class-A, Class-B, Class-F and Electrically Started Fires, Built-in pressure gauge, lnstalert, Uses distilled water, Gross Weight 12.15 Kg, empty Weight 6.15kg, can Height 615mm Diameter 175M M, Controllable discharge mechanism (Squeeze grip with easy snap safety seal), Can Construction: Deep drawn & C02 Mig welded, Valve Construction: Forgin & Machining, ERDA approved, Sheet metal thickness : 2.00MM, Discharge Time : Min. 64 Sec 5 Year Warranty with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost cost of supporting materials like MS stand & accessaries if it is fixing n floor / MS brackets and accessories if it is fixing on wall,, labour, usage charges of machinery with all leads and lifts complete as per specification anf as direted by the Engineer incharge of the work (Near Staircase)Nos7700.07700.02.0FalseNoneNoneFalseNoneFalse15400.00
243672173308NoneBYD250Supply and installation of 4.5Kg C02 Gas Type aluminium body Squeeze grip Fire Extinugisher, Trolley Mounted, Easy Weight Management, Used Unused Mechanism, Squeeze Grip, Gross Weight 11.16Kg. empty Weight 6.66Kg. Can Height 860MM Diameter 140MM, Discharge Time less than10 Sees, Controllable discharge mechanism, Applicable on Class 8&C Fire, 8 Rating 138, Can Constuction : Cold Impact Extrusion, Valve Construction Forging & Machining, Internal Coating of Can : Not Applicable, External coating of Can Spray Painting, Aluminium metal ISO and PESO Approved, 3 Year Warranty. including cost cost of supporting materials like MS stand & accessaries if it is fixing n floor / MS brackets & accessories if it is fixing on wall labour, usage charges of machinery with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work (For electrical room & utilities)Nos7500.07500.01.0FalseNoneNoneFalseNoneFalse7500.00
243672273308NoneBYD251Supply, installation in position, testing and commissioning of 6kg Fire Extinguisher Mono Ammonium Phosphate Powder 90, Stored Pressure Type, Pressure Gauge, Gross Weight 9.40 Kg, empty weight 3.4 Kg,Can Height 480MM, Diameter 160MM, Discharge Time less than 13 Sees,Controllable discharge mechanism (Squeeze grip with easy snap safety seal), Range minimum 4 meters, applicable on Class A,B, C and electrically started Fire, A Rating 3A, B Rating 21B, Can construction Deep drawn and Co Mig welded, valve Construciton Forging and Mechining, Internal Coating of Can: Epoxy powder coating, External Coating of Can Epoxy Polyster power coating, Sheet metal thickness 1.60MM, 5 years Warranty with instalert system with Superior quality EPDM Rubber Hosepipe etc including cost of materials, labour, usage charges of machinery complete as per specifications. complete IS 15683 and CE Approved with all leads and lifts complete as per specification anf as direted by the Engineer incharge of the workNos2550.02550.08.0FalseNoneNoneFalseNoneFalse20400.00
243672373308NoneBYD252Supplying of four bucket stand along with buckets. Complete. with all leads and lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNos1850.01850.02.0FalseNoneNoneFalseNoneFalse3700.00
243672473308NoneBYD253Supplying of Hand gloves. Complete. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNos975.0975.02.0FalseNoneNoneFalseNoneFalse1950.00
243672573308NoneBYD254Supplying of first aid box. Complete with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the workNos600.0600.01.0FalseNoneNoneFalseNoneFalse600.00
243672673308NoneBYD255Supplying of SAFETY MASK. Complete. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work this rate is inclusive of form workNos150.0150.02.0FalseNoneNoneFalseNoneFalse300.00
243672773308NoneBYD256Supplying of FIRST AID CHART with lamination.Complete with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the workNos400.0400.01.0FalseNoneNoneFalseNoneFalse400.00
243672873308NoneBYD257Providings Escape Singage Photo lumines centrigid plastic,2mm thickness,Printed on High Quality glass paint with UV resistance,5years warranty,Material Used Non Radiocactive,non phosphorous,non toxic and lead free.Available in different types & sizes,Time after removing the light source (inminutes) 60minutes, Luminescent intensity (milicandelas x persquaremeter-mcd/sqm)30mcd/sqm. Luminescent Intensity greater than 0.32mcd/sqm,Period of Light Decay(InMinutes)3100, including cost of materials,labour,usage charges of machinery complete as per specifications. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the workNos2500.02500.02.0FalseNoneNoneFalseNoneFalse5000.00
243672973308NoneBYD258Supply, Installation testing and commissioning of approved make heavy tubes (Class C) confirming to as per IS1239 Part I (25mm Nominal bore 4.05mm thickat 2.97 Kg/m, 32mm Nominal bore 4.05mm thick at 3.84 Kg/m, 40mm Nominal bore 4.05mm thickat 4.43 Kg/m,50mm Nominal bore 4.47mm thick at 6.17 Kg/m, 65mm Nominal bore 4.47mm thick at 7.90 Kg/m, 80mm Nominal bore 4.85mm thick at 10.10 Kg/m, 100mm Nominal bore 5.40mm thick at 14.40 Kg/m,150mm Nominal bore, 5.40mm thick at 21.20 Kg/m, Such as Tees elbows check nuts unions, Flanger, Nipples etc. including cutting welding, Trending fixing on walls, ceiling (Using 41- Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. including cost of materials, labour, usagecharges of machinery with all leads and lifts complete as per specification anf as direted by the Engineer incharge of the work 150mm nominal diaMtr3900.03900.020.0FalseNoneNoneFalseNoneFalse78000.00
243673073308NoneBYD259Supply, Installation testing and commissioning of approved make heavy tubes (Class C) confirming to as per IS1239 Part- I (25mm Nominal bore 4.05mm thick@ 2.97 Kg/m, 32mm Nominal bore 4.05mm thick at 3.84 Kg/m, 40mm Nominal bore 4.05mm thick at 4.43 Kg/m,50mm Nominal bore 4.47mm thickat 6.17 Kg/m, 65mm Nominal bore 4.47mm thick at 7.90 Kg/m, 80mm Nominal bore 4.85mm thick at 10.10 Kg/m, 100mm Nominal bore 5.40mm thick at 14.40 Kg/m,150mm Nominal bore, 5.40mm thick at 21.20 Kg/m, Such as Tees elbows check nuts unions, Flanger, Nipples etc. including cutting welding, Trending fixing on walls, ceiling (Using 41- Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. including cost of materials, labour, usagecharges of machinery with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work 100mm nominal diaMtr2850.02850.030.0FalseNoneNoneFalseNoneFalse85500.00
243673173308NoneBYD260Supply, Installation testing and commissioning of approved make heavy tubes (Class C) confirming to as per IS1239 Part- I (25mm Nominal bore 4.05mm thick at 2.97 Kg/m, 32mm Nominal bore 4.05mm thick at 3.84 Kg/m, 40mm Nominal bore 4.05mm thick at 4.43 Kg/m,50mm Nominal bore 4.47mm thick at 6.17 Kg/m, 65mm Nominal bore 4.47mm thick at 7.90 Kg/m, 80mm Nominal bore 4.85mm thick at 10.10 Kg/m, 100mm Nominal bore 5.40mm thick at 14.40 Kg/m,150mm Nominal bore, 5.40mm thick at 21.20 Kg/m, Such as Tees elbows check nuts unions, Flanger, Nipples etc. including cutting welding, Trending fixing on walls, ceiling (Using 41- Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. including cost of materials, labour, usagecharges of machinery with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work 80mm nominal diaMtr2300.02300.070.0FalseNoneNoneFalseNoneFalse161000.00
243673273308NoneBYD261Supply, Installation testing and commissioning of approved make heavy tubes (Class C) confirming to as per IS1239 Part- I (25mm Nominal bore 4.05mm thick at 2.97 Kg/m, 32mm Nominal bore 4.05mm thick at 3.84 Kg/m, 40mm Nominal bore 4.05mm thick at 4.43 Kg/m,50mm Nominal bore 4.47mm thick at 6.17 Kg/m, 65mm Nominal bore 4.47mm thick @ 7.90 Kg/m, 80mm Nominal bore 4.85mm thick at 10.10 Kg/m, 100mm Nominal bore 5.40mm thick@ 14.40 Kg/m,150mm Nominal bore, 5.40mm thick at 21.20 Kg/m, Such as Tees elbows check nuts unions, Flanger, Nipples etc. including cutting welding, Trending fixing on walls, ceiling (Using 41- Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. including cost of materials, labour, usagecharges of machinery with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work 65mm nominal diaMtr1700.01700.088.0FalseNoneNoneFalseNoneFalse149600.00
243673373308NoneBYD262Supply, Installation testing and commissioning of approved make heavy tubes (Class C) confirming to as per IS1239 Part- I (25mm Nominal bore 4.05mm thick at 2.97 Kg/m, 32mm Nominal bore 4.05mm thick at 3.84 Kg/m, 40mm Nominal bore 4.05mm thick at 4.43 Kg/m,50mm Nominal bore 4.47mm thick at6.17 Kg/m, 65mm Nominal bore 4.47mm thick at 7.90 Kg/m, 80mm Nominal bore 4.85mm thick at 10.10 Kg/m, 100mm Nominal bore 5.40mm thick at 14.40 Kg/m,150mm Nominal bore, 5.40mm thick at 21.20 Kg/m, Such as Tees elbows check nuts unions, Flanger, Nipples etc. including cutting welding, Trending fixing on walls, ceiling (Using 41- Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. including cost of materials, labour, usagecharges of machinery with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work 50mm nominal diaMtr1300.01300.060.0FalseNoneNoneFalseNoneFalse78000.00
243673473308NoneBYD263Supply, Installation testing and commissioning of approved make heavy tubes (Class C) confirming to as per IS1239 Part- I (25mm Nominal bore 4.05mm thick at 2.97 Kg/m, 32mm Nominal bore 4.05mm thick @ 3.84 Kg/m, 40mm Nominal bore 4.05mm thick@ 4.43 Kg/m,50mm Nominal bore 4.47mm thick@ 6.17 Kg/m, 65mm Nominal bore 4.47mm thick at 7.90 Kg/m, 80mm Nominal bore 4.85mm thick @ 10.10 Kg/m, 100mm Nominal bore 5.40mm thick@ 14.40 Kg/m,150mm Nominal bore, 5.40mm thick @ 21.20 Kg/m, Such as Tees elbows check nuts unions, Flanger, Nipples etc. including cutting welding, Trending fixing on walls, ceiling (Using 41- Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. including cost of materials, labour, usagecharges of machinery with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work 40mm nominal diaMtr1050.01050.010.0FalseNoneNoneFalseNoneFalse10500.00
243673573308NoneBYD264Supply, Installation testing and commissioning of approved make heavy tubes (Class C) confirming to as per IS1239 Part- I (25mm Nominal bore 4.05mm thick at 2.97 Kg/m, 32mm Nominal bore 4.05mm thick at 3.84 Kg/m, 40mm Nominal bore 4.05mm thick at 4.43 Kg/m,50mm Nominal bore 4.47mm thick at 6.17 Kg/m, 65mm Nominal bore 4.47mm thick at 7.90 Kg/m, 80mm Nominal bore 4.85mm thick at 10.10 Kg/m, 100mm Nominal bore 5.40mm thick at 14.40 Kg/m,150mm Nominal bore, 5.40mm thick at 21.20 Kg/m, Such as Tees elbows check nuts unions, Flanger, Nipples etc. including cutting welding, Trending fixing on walls, ceiling (Using 41- Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. including cost of materials, labour, usagecharges of machinery with all leads and lifts complete as per specification anf as direted by the Engineer incharge of the work 32mm nominal diaMtr800.0800.032.0FalseNoneNoneFalseNoneFalse25600.00
243673673308NoneBYD265Supply, Installation testing and commissioning of approved make heavy tubes (Class C) confirming to as per IS1239 Part- I (25mm Nominal bore 4.05mm thick at 2.97 Kg/m, 32mm Nominal bore 4.05mm thickat 3.84 Kg/m, 40mm Nominal bore 4.05mm thick at 4.43 Kg/m,50mm Nominal bore 4.47mm thickat 6.17 Kg/m, 65mm Nominal bore 4.47mm thick at 7.90 Kg/m, 80mm Nominal bore 4.85mm thick at 10.10 Kg/m, 100mm Nominal bore 5.40mm thick at 14.40 Kg/m,150mm Nominal bore, 5.40mm thick at 21.20 Kg/m, Such as Tees elbows check nuts unions, Flanger, Nipples etc. including cutting welding, Trending fixing on walls, ceiling (Using 41- Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. including cost of materials, labour, usagecharges of machinery with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work 25mm nominal diaMtr700.0700.0480.0FalseNoneNoneFalseNoneFalse336000.00
243673773308NoneBYD266Supply, Installation testing and commissioning of approved make heavy tubes (Class C) confirming to as per IS1239 Part- I (25mm Nominal bore 4.05mm thick 2.97 Kg/m, 32mm Nominal bore 4.05mm thick 3.84 Kg/m,40mm Nominal bore 4.05mm thick 4.43 Kg/m,50mm Nominal bore 4.47mm thick 6.17 Kg/m, 65mm Nominal bore 4.47mm thick 7.90 Kg/m, 80mm Nominal bore 4.85mm thick 10.10 Kg/m, 100mm Nominal bore 5.40mm thick14.40 Kg/m,150mm Nominal bore, 5.40mm thick 21.20 Kg/m, Such as Tees elbows check nuts unions, Flanger, Nipples etc. including cutting welding, Trending fixing on walls, ceiling (Using 41- Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. including cost of materials, labour, usage charges of machinery complete as per specifications. Wraping and Galing of U/G pipe line work includes one coat of anti corrossion paint (Black) and two coats of Bituminous cloth. including cost of materials, labour, usage charges of machinery with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work 200mm nominal diaMtr4300.04300.020.0FalseNoneNoneFalseNoneFalse86000.00
243673873308NoneBYD267Supplying, installing , testing and commissioning of PN16 CI butterfly valves of confirming to IS 13039 with necessary nuts & bolts etc complete etc complete as per specificaiton with all lead and lift, loading unloading, labour,hire charges of machineries and all such incidental charges necessary for successful with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work 150mm diaNos12500.012500.02.0FalseNoneNoneFalseNoneFalse25000.00
243673973308NoneBYD268Supplying, installing, testing and commissioning conventional Sprinkler quartzoid bulb type with 15mm screwed end connection of 68 deg. C. temperature rating,K 80 and orifice shall not be less than 6mm.Sprinklers shall be UL Listed / FM approved with Chrome finished. Pendent sprinkler with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the workNos375.0375.0260.0FalseNoneNoneFalseNoneFalse97500.00
243674073308NoneBYD269Supplying Installing, testing and commissioning of hydraulically operated sprinkler Gong Valve with water meter gong bell and trims as required,pressure gauges drain Valve, ball Valves check valve, strainer etc.including cost of materials, labour, usage charges of machinery complete as perspecifications. 150mm dia. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the workNos70000.070000.01.0FalseNoneNoneFalseNoneFalse70000.00
243674173308NoneBYD270Supplying, installing, testing and commissioning flow switch on sprinkler distribution header on each floor and shall be connected to fire alarm panel through cable. Cable shall be measured separately. 150 mm flow switch with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the workNos6000.06000.02.0FalseNoneNoneFalseNoneFalse12000.00
243674273308NoneBYD271Supplying, installing, testing and commissioning of Sight glass of 40 mm dia.and necessary fittings like union, ballvalve etc cpmlete set. (BRONZE) with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the workNos7500.07500.02.0FalseNoneNoneFalseNoneFalse15000.00
243674373308NoneBYD272Supplying Installing, testing and commissioning of Gun metal BALL VALVE SIZE OF 25mm dia including cost of materials, labour, usage charges of machinery complete as per specifications. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the work 25 mm diaNos1200.01200.02.0FalseNoneNoneFalseNoneFalse2400.00
243674473308NoneBYD273Supplying Installing, testing and commissioning of Gun metal AIR RELEASE VALVE SIZE OF 25mm dia including cost of materials, labour, usage charges of machinery complete as per specifications. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the workNos1500.01500.01.0FalseNoneNoneFalseNoneFalse1500.00
243674573308NoneBYD274addressable peer to peer Networkable analogue addressable type fire alarm control panel with minimum 1500 Character / 240X64 Pixel / 7inch Touchscreen graphic LCD display. The panel should be equipped with sufficient numbers of loop with 20% spare capacity, with each networkable intelligent fire alarm Control Panel having SLC with capacity of min 126 /240 detectors/ devices in any combination with key pad, dual flash-based microprocessor technology, inbuilt USB Port for upload and down load the configuration tools, RS232 serial port for direct PC or modem connection, inbuilt NACs, min 20 programmable Zonal LEDs and operates on 240V AC 10% with 50 Hz with built in charger. The panel shall have fire, fault relays, option of BMS integration MODBUS/ BACKNET, graphical software for provision of TCP/ IP modules, Remote Access, Class X wiring with provision of both class 'A' and class 'B' wiring in the SLC circuit, user friendly with communication facility to monitor & control the FACPs from a single window. The panel shall be suitable for minimum of 5000 event record facility, event fetch from FACP facility and the single panel shall be suitable for min 2000 fire zones and 200 Panels/ Nodes in one network with all other accessories required to successfully run the system. (The System cost shall be included of all necessary cards, modules, Panel enclosure, CPU and associated accessories to complete the system design) Approval: VDS/UL/EN-54 Std with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the workNo210000.0210000.01.0FalseNoneNoneFalseNoneFalse210000.00
243674673308NoneBYD275Supply, installation, testing and commissioning of analogue addressable Smoke Sensor detector and standard base (For Detectors/Device without inbuilt isolator, Fault Isolator or Isolator base to be provided with each detector/device) Approval: VDS/UL/EN54. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the workNos3300.03300.085.0FalseNoneNoneFalseNoneFalse280500.00
243674773308NoneBYD276Supply, install, test and commissioning of Analogue addressable Monitor Cum Control (Input/Output) module (1+1) with inbuilt relay and isolator with LED indicator, approved to operate in 10C to +55C temperature,complies with the essential requirement of the EMC Directive to be supplied with Junction Box, Glands and other mounting accessories for proper installation. In case of Manufacturer with single Input or Output module need to supply One quantity of each for line item. (For Detectors/Device without inbuilt isolator, Fault Isolator or Isolator base to be provided with each detector/device) Approval: EN54. For DetectorsFor HOOTER with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the workNos3900.03900.06.0FalseNoneNoneFalseNoneFalse23400.00
243674873308NoneBYD277Supply, install, test and commissioning of Analogue addressable Monitor Cum Control (Input/Output) module (1+1) with inbuilt relay and isolator with LED indicator, approved to operate in 10C to +55C temperature, complies with the essential requirement of the EMC Directive to be supplied with Junction Box, Glands and other mounting accessories for proper installation. In case of Manufacturer with single Input or Output module need to supply One quantity of each for line item. (For Detectors/Device without inbuilt isolator, Fault Isolator or Isolator base to be provided with each detector/device) Approval: EN54. (supervisory switch /Limit switch ) with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the workNos3900.03900.02.0FalseNoneNoneFalseNoneFalse7800.00
243674973308NoneBYD278Supply, install, test and commissioning of Analogue addressable Monitor Cum Control (Input/Output) module (1+1) with inbuilt relay and isolator with LED indicator, approved to operate in 10C to +55C temperature, complies with the essential requirement of the EMC Directive to be supplied with Junction Box, Glands and other mounting accessories for proper installation. In case of Manufacturer with single Input or Output module need to supply One quantity of each for line item. (ForDetectors/Device without inbuilt isolator, Fault Isolator or Isolator base to be provided with each detector/device) Approval: EN54. For Flow Switch with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the workNos3900.03900.02.0FalseNoneNoneFalseNoneFalse7800.00
243675073308NoneBYD279Supply, Installation, Testing and Commissioning of Analogue Addressable loop powered Sounder & Beacon with inbuilt isolator and having Min 15 distinct sound patterns/ multitone to indicate Exit doors and direct occupants for safe and fast evacuation and 100dB output with minimum 1Hz Frequency flash rate designed for IP65 requirements and approved to operate in 10C to +55C temperature, complies with the essential requirement of the EMC Directive to be supplied with Junction Box, Glands and other mounting accessories for proper installation. (For Detectors/ Device without inbuilt isolator, Fault Isolator or Isolator base to be provided with each detector/device) with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the workNos4900.04900.02.0FalseNoneNoneFalseNoneFalse9800.00
243675173308NoneBYD280Supply, install, test and commissioning of Analogue addressable Manual Call Point (Resettable Type) with inbuilt isolator and LED indicator, designed for IP44 requirements and approved to operate in 10C to +55C temperature, complies with the essential requirement of the EMC Directive to be supplied with Barriers, Junction Box, Glands and other mounting accessories for proper installation. (For Detectors/Device without inbuilt solator, Fault Isolator or Isolator base to be provided with each detector/device) Approval: VDS. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the workNos3000.03000.02.0FalseNoneNoneFalseNoneFalse6000.00
243675273308NoneBYD281Supplying, installing, testing and commissioning of PVC (FRLS) insulated copper armoured cable confirming to IS standards and specifications. Including flow switch 2 core x 2.5 Sq.mm armoured cable with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the workMtr62.1662.161600.0FalseNoneNoneFalseNoneFalse99456.00
243675373308NoneBYD282Supplying heavy gauge PVC conduit pipe 25 mm dia 2 mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. with all leads and lifts complete as per specification anf as direted by the Engineer incharge of the workMtr81.081.01500.0FalseNoneNoneFalseNoneFalse121500.00
243675473308NoneBYD283Supplying Installing, testing and commissioning of P.A.System console panel 10 Zone with push button with speaker and indictoron Accomdated in M.S.Cabinet with painting including cost of materials, labour, usage charges of machinery complete as per specifications with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the workNos35000.035000.01.0FalseNoneNoneFalseNoneFalse35000.00
243675573308NoneBYD284P.A.System amplifier 250W RM S out put with complete wiring and controls accessable form front with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the workNos35250.035250.01.0FalseNoneNoneFalseNoneFalse35250.00
243675673308NoneBYD285Supplying Installing, testing and commissioning of Public address system (Two way comminication type) as per requirement of Fire Force authority and which Generally comprise of Supplying Installing, testing and commissioning of Approved make 6 W.wall mounted speaker with talk back facility with store enamel painted M.S.Sheet hosing etc. complete including cost of materials, labour, usage charges of machinery complete as per specifications. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the workNos2450.02450.02.0FalseNoneNoneFalseNoneFalse4900.00
243675773308NoneBYD286Supplying, installing, testing and commissioning of 4 core x 1.5sq.mm Screened Microphone cable or MIC flexible cable, black/Grey matt finish PVC low noise cable with tinned copper screening. High quality mic cable for Public Announcement. For wall mounted / intercomm speaker.(FRLS) with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the workMtr94.094.0150.0FalseNoneNoneFalseNoneFalse14100.00
243675873308NoneBYD287Supplying heavy gauge PVC conduit pipe 25 mm dia 2 mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the workMtr81.081.0140.0FalseNoneNoneFalseNoneFalse11340.00
243675973308NoneBYD288Supply. installation, testing and commissioning of plant and equipment for cold stores as per the specifications. (1) Ambient Temperature [in C] 38 Deg C (2) Designed Room Temperature [ 2 C] + 2 to 8 Deg C (3) Designed Room Humidity [ RH] More than 90% RH (4) Product to be stored Chillies and spices (5) Product Incoming Temperature [C] Plus 28 to 33 deg C (6) Product Room Temperature Deg C Plus 2 to 8 Deg C (7) Qty of Product stored per day/batch [in kg] apply 29000 kg / day (8) Pull down time [Hrs] 48 Hrs (9) Specific heat [Cp] Above Freezing [kJ/kg K] 3.8 kJ/kg K (10) Material of Insulation RPUF (11) Thickness of Insulation [mm] wall and ceiling 80 mm (12) Wall Lamination In/Out PPGI/PPGI (13) Ceiling In/Out PPGI/PPGI (14) Serration on panel To be Provided (15) Floor insulation RPUF PUF slab with Polysheet on both sides (16) Thickness of Insulation (mm) for floor 60mm (17) Size of Door 1800x2400 Ht mm PCGI Finish (18) Type of Door PUF Insulated manual sliding type (19) Type of refrigeration system Split Type-Individual Refrigeration system common for 2 pre-cooling chambers and 4 cold storage rooms (20)Type of Cooling DX Type (21) Capacity of centralized refrigeration system 56 TKW (22) Type of Refrigerant R404a (23) Type of Compressor Hermetic (24) Type of Condenser Air-Cooled (25) Capacity condensing unit 14kW x 4 Sets each room To suit the Refrigeration System with R404A which can work from -3C up to +10 evaporating temperature (26) Capacity of Evaporator unit 4x14KW EACH (Or to be suggested by manufacturer/bidder) (27) Number of Evaporator Units 16 UNITS + 2 FOR Pre cooling (28) Electrical Panel for Ref System To be Inbuilt in condensing unit (29) Type of evaporator units Forced Air Cooled (30) MOC for evaporator and Condenser units Ceiling suspended PPGI casing with tube axial fan (31)Temperature / humidity indicator-cum-controller Micro-Processor based controller (32) Lighting Inside the rooms Suitable for 50 Lux luminosity (33) Type of light fitting High bay LED (34) Interconnecting piping and wiring between the Condenser and Evaporator units As per actual as per drawing (35) GI Perforated Grating for Mezzanine as detailed here for Mezzanine floor GI Gratings with 30% opening. GI Grating size for 1000 kgs UDL suitability is 200x500 mm. 2mm Thickness GI Sheet to be used. for detailed technical specification refer annexure in KW4 bid document. with all leads & lifts complete as per specification anf as direted by the Engineer incharge of the workSet28631000.028631000.01.0FalseNoneNoneFalseNoneFalse28631000.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17071136840000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17071136840000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17071136840000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17071138030000NoneNoneELIGIBILITYCONDITIONS AS PER KW4 UPLODED IN THIS TENDERNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)NoneNone
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)NoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneAll Tenderers shall provide the requested information accurately and in sufficient detail in Section 3 Qualification information.OthersTECHNICAL CRITERIA AS PER SECTION 3
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- AS PER SECTION 3
NoneNoneNoneNoneTechnical CriteriaOthersTechnical Criteria as per tender documents kw4
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneother documents as per kw4 uplodedOthersother documents as per kw4 uploded
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- other documents as per kw4 uploded
NoneNoneNoneNonePWD Registration certificate as per kw4OthersPWD Registration certificate as per kw4
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneEquipment capacity in kw4 section 3 3.3OthersEquipment capacity as per kw-4 uploded
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Equipment capacity as per kw-4 uploded
NoneNoneNoneNoneManufacturer of Cold store/Cold Room/Cold Chain Plant and equipment section 3.2 eOthersManufacturer of Cold store/Cold Room/Cold Chain Plant and equipment as per kw4 uploded
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Manufacturer of Cold store/Cold Room/Cold Chain Plant and equipment as per kw4
NoneNoneNoneNoneidentified sub-contractor should possess required valid electrical license in section 3.2 dOthersidentified sub-contractor should possess required valid electrical license as per kw-4 uploded
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- identified sub-contractor should possess required valid electrical license as per kw-4 uploded
NoneNoneNoneNoneminimum quantities of work section 3.2 cOthersminimum quantities of work as per kw4 uploded
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- minimum quantities of work as per kw4 uploded
NoneNoneNoneNoneas per section 3.2 bOtherssatisfactory completion as per kw4 uploded
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- satisfactory completion as per kw4 uploded
NoneNoneNoneNoneTo qualify for award of this contract each Tenderer in his name should have in the last five years ie 201819 to 202223 a)Achieved in any two financial years a minimum financial turnover in all classes of civil engineering construction works only of Rs 1971 lakhs The certificate with UDIN is to be attested by a Chartered Accountant. Otherwise the tender will be rejectedOthersFINACIAL TURNOVER as per kw4
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- FINACIAL TURNOVER as per kw4
NoneNoneNoneNoneTechnical CriteriaOthersTechnical Criteria as per kw4 uploded
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneTechnical CriteriaOthersTechnical Criteria as per tender documents
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneGST Registration
NoneNoneNoneNoneTechnical CriteriaOthersTechnical Criteria as per kw4 uploded
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- PAN IT RETURNS AND OTHER DOCUMENTS
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateFalseTechnical Bid
Company Registration CertificateFalseTechnical Bid
ALL OTHER DOCUMENTS AS PER KW4 UPLODEDFalseTechnical Bid
tenderWorkLocationList
tenderSubEstimateNamedistrictNametaluqNameloksabhaContNameassemblyContNamelocationDescriptionlatitudeDegreeslatitudeMinuteslatitudeSecondslongitudeDegreeslongitudeMinuteslongitudeSeconds
BuildingsHaveriByadgiNoneNoneCHIKKABASUR SUB MARKET YARD OF APMC BYADGINoneNoneNoneNoneNoneNone
tenderAddress
createdTs1707119713000
version0
createdDateNone
modifiedDateNone
blockNumberAPMC BYADGI OFFICE BUILDING
streetNone
cityBYADGI
stateKarnataka
pin581106
tenderRecallDTONone