createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1706962974084
version3
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeONE_COVER
evaluationTypeTextOne Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeEXCLUSIVE_TAX
tenderFee590.00
emd58500.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose19-02-2024 17:00:00
tenderQueryClose17-02-2024 17:00:00
technicalBidOpenNone
publishedDate05-02-2024 12:50:39
publishedByPostCMC_MCOM_HSPT
publishedByUserKPE12911 - ERAGUDI SHIVAKUMAR
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonMunicipal commissioner
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber9620079006
tenderSupplierListNone
tenderSchedule
createdTs1706962974112
version6
createdDateNone
modifiedDateNone
tenderNumberDMA/2023-24/WS/WORK_INDENT14206
titlePackage 1 1.Drilling of borewell fixing of motor & pipeline work at Kuruber Oni in Ward no 01, 2.near Huligemma gudi beside Venugopal temple patel nagar in Ward no 03, 3.at Gandhi nagar 8th cross and near Kariyamma gudi Kanakadas circle in Ward no 04, 4.at Ranipete in Ward no 05, 5.Drilling of borewell, fixing of motor, construction of cistern tank & pipeline work at Hampi road and Sunnada bhatti area in Ward no 06 in Hospet limit.
descriptionPackage 1 1) Drilling of borewell, fixing of motor and pipeline work at Kuruber Oni in Ward no 01 in Hospet limit. 2) Drilling of borewell, fixing of motor and pipeline work near Huligemma gudi beside Venugopal temple patel nagar in Ward no 03 in Hospet limit. 3) Drilling of borewell, fixing of motor and pipeline work at Gandhi nagar 8th cross and near Kariyamma gudi Kanakadas circle in Ward no 04 in Hospet limit. 4) Drilling of borewell fixing of motor and pipeline work at Ranipete in Ward no 05 in Hospet limit. 5) Drilling of borewell, fixing of motor, construction of cistern tank and pipeline work at Hampi road and Sunnada bhatti area in Ward no 06 in Hospet limit.
categoryWORKS
categoryTextWorks
ecv2340000.00
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2475
locationNameDMA City Municipal Council Hosapete
provisionalAmount2340000.0
groupOverheadTotal370009.86
fileNumbercmc/hpt/15fin/ws/2023-24/1
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17069629740000NoneNoneWater supply/sewage linesPackage 1 1.Drilling of borewell fixing of motor & pipeline work at Kuruber Oni in Ward no 01, 2.near Huligemma gudi beside Venugopal temple patel nagar in Ward no 03, 3.at Gandhi nagar 8th cross and near Kariyamma gudi Kanakadas circle in Ward no 04, 4.at Ranipete in Ward no 05, 5.Drilling of borewell, fixing of motor, construction of cistern tank & pipeline work at Hampi road and Sunnada bhatti area in Ward no 06 in Hospet limit.1969990.14
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
242436172759Nonecode01Geophysical investigation of site for Sinking borewell of for supplying drinking water to the habitation either through the hand pump MWS or PWSS by vertical electrical sounding by adopting venner or Schlumbergers method including reconnaissance survey of Geoological formation Geophysical investigation of exisiting ground water in the vicinity indicating the location of site recommended depth of casing pipe required to seal the top unconsolidated formation including and depth of 1.0 meter in cosolidated formation for proper seating of casing pipe depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yeild and other information required including transportation of instrument and occessories to work site engaging technical personnel and labour required etc.Each5552.45552.42.0FalseNoneNoneFalseNoneFalse11104.80
242436272759Nonecode02Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG above 1100 CMF above in all strata including over burdern. Fixing of casing pipes collars and cap with necessary cutting threading and welding including transportation of rig and supporting vehicle crew charges and cost of consumables etc. complete including yield testing at the final depth with a minimum working of compressor for one hour Excluding cost of casing pipes collars cap etc complete 0 to 50 Mtr depthMtr324.45324.45100.0FalseNoneNoneFalseNoneFalse32445.00
242436372759Nonecode03Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG above 1100 CMF above in all strata including over burdern. Fixing of casing pipes collars and cap with necessary cutting threading and welding including transportation of rig and supporting vehicle crew charges and cost of consumables etc. complete including yield testing at the final depth with a minimum working of compressor for one hour Excluding cost of casing pipes collars cap etc complete 50 to 100 Mtr depthMtr406.35406.35100.0FalseNoneNoneFalseNoneFalse40635.00
242436472759Nonecode04Cost of 160 mm dia PVC Casing pipeMtr648.9648.936.0FalseNoneNoneFalseNoneFalse23360.40
242436572759Nonecode05Supply of Bore capNo172.2172.22.0FalseNoneNoneFalseNoneFalse344.40
242436672759Nonecode06Supply of GI clamp setNo300.0300.02.0FalseNoneNoneFalseNoneFalse600.00
242436772759Nonecode07Providing, supplying to work site,Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications,with testing of as per instructions of engineer incharge of work and latest amendments. 2.00 HP/1.5KW 16 STGNo19767.319767.32.0FalseNoneNoneFalseNoneFalse39534.60
242436872759Nonecode08Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core sheathed of nominal cross sectional area as per IS 694 1990 with ISI Mark and as per its latest amendments. 1x3x2.5 Sqm.Mtr89.2589.2590.0FalseNoneNoneFalseNoneFalse8032.50
242436972759Nonecode09Providing main connection from pole PVC insulated sheathed steel wire cable in new trench as per IS 1554/ 1988 with latest amendments with ISI mark from KPTCL pole to meter board unit.Mtr141.75141.7540.0FalseNoneNoneFalseNoneFalse5670.00
242437072759Nonecode10Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia.Each3937.53937.52.0FalseNoneNoneFalseNoneFalse7875.00
242437172759Nonecode11Supply installing testing and commissioning COMMON control panel consisting of the following INCOMING1 No set of Phase indicating lamps with SFU of suitable rating 1 No Analog Ammeter 1 No Analog Voltmeter 1ni with Phase selector switch Isolating switch OUTGOING for Main Electrical Pump 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor under voltage over Volage under current over current & dry run protection suitable for the pump described above 1 no Indoor type DOLDirect Online Starter Upto 6 HP pumpsEach7875.07875.02.0FalseNoneNoneFalseNoneFalse15750.00
242437272759Nonecode12Supplying laying jointing testing and commissioning of G.I. Pipes conforming to IS 1239 1990 with latest amendments including fixing Collars Elbows Tees bends Glad Cocks and other Fittings Excluding Cost of Specials with Cuts and Threads wherever necessary including conveying the materials to workspot including testing for water tightness with all lead and lifts etc complete Contractor shall make his own arrangements for procuring water for testing Class-C HEAVY 40 mm dia GI PIPEMtr522.9522.972.0FalseNoneNoneFalseNoneFalse37648.80
242437372759Nonecode13Supplying laying jointing testing andcommissioning of G.I. Pipes conforming to IS 1239 1990 with latest amendments including fixing Collars Elbows Tees bends Glad Cocks and other Fittings Excluding Cost of Specials with Cuts and Threads wherever necessary including conveying the materials to workspot including testing for water tightness with all lead and lifts etc complete Contractor shall make his own arrangements for procuring water for testingClass-C HEAVY 20 mm dia GI PIPETapMtr276.15276.1520.0FalseNoneNoneFalseNoneFalse5523.00
242437472759Nonecode14Providing wrought mild steel galvanized 15 mm dia GI collar confirming to IS 1239-II 1991 with latest amendments if any. For 40 mm dia GI collarEach216.3216.310.0FalseNoneNoneFalseNoneFalse2163.00
242437572759Nonecode15Supply and delivery at site wrought middle steel galvanized GI bend confirming to IS 1239-II 1991 with latest amendments if any For 40 mm dia GI BENDEach280.35280.358.0FalseNoneNoneFalseNoneFalse2242.80
242437672759Nonecode16Supply and delivery at site wrought middle steel (galvanized) GI Socket confirming to IS 1239-II, 1991 with latest amendments if any.. For 40 mm dia GI SocketEach232.05232.054.0FalseNoneNoneFalseNoneFalse928.20
242437772759Nonecode17Supply and delivery at site wrought middle steel galvanized GI Union confirming to IS 1239-II 1991 with latest amendments if any. For 40 mm dia GI UnionEach192.15192.152.0FalseNoneNoneFalseNoneFalse384.30
242437872759Nonecode18Supply and delivery at site wrought middle steel (galvanized) GI hexagonal nipple confirming to IS 1239-II, 1991 with latest amendments if any.Each248.85248.854.0FalseNoneNoneFalseNoneFalse995.40
242437972759Nonecode19Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments Size 40 mmNo1312.51312.52.0FalseNoneNoneFalseNoneFalse2625.00
242438072759Nonecode20Cutting road surfaces for pipeline trenches and disposing of the excavated stuff as directed including barricading, danger lighting etc. in the classifications for: Cutting Cement Concrete Road surface by Machine cutting to demarcate the trench width of the surface.Cum998.55998.559.0FalseNoneNoneFalseNoneFalse8986.950
242438172759Nonecode21Earth work excavation for pipelines/cables by Manual means upto 600mm trench width as per drawing and technical specifications including setting out shoring strutting barricading caution lights removal of stumps and other deleterious matter including dressing of excavated surfaces disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth excluding rock in trenches plinth sides of foundations etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour tools usage& other appurtenances required to complete the work.Cum508.2508.2108.0FalseNoneNoneFalseNoneFalse54885.60
242438272759Nonecode22Supplying laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches laying true to line and jointing of pipes and specials with electrofusion welding giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends flanged sets bedns reducers etc. complete Contractor will make his own arrangements for procuring water for testing etc. Note Upto 110mm dia Coil shall be used. HDPE Grade -PE80 conforming to IS 4984- 1995 PN 6.0 / 6 Kg/cm2 63 mm dia.Mtr198.45198.45400.0FalseNoneNoneFalseNoneFalse79380.00
242438372759Nonecode23Refilling available earth around trenches/pipelines cables in layers not exceeding 20 cms in depth compacting each deposited layer by ramming after watering with a lead upto 50 m and lift upto 1.5 m. Including cost of all labour complete as per specifications.Cum168.0168.0108.0FalseNoneNoneFalseNoneFalse18144.00
242438472759Nonecode2490X63 MM ELECTRO FUSION REDUCEREach464.1464.15.0FalseNoneNoneFalseNoneFalse2320.50
242438572759Nonecode2590 MM ELECTRO FUSION TEEEach258.3258.310.0FalseNoneNoneFalseNoneFalse2583.00
242438672759Nonecode2690 MM ELECTRO FUSION COUPLEREach148.05148.0510.0FalseNoneNoneFalseNoneFalse1480.50
242438772759Nonecode2790 MM ELECTRO FUSION ELBOWEach259.35259.3515.0FalseNoneNoneFalseNoneFalse3890.250
242438872759Nonecode2820 mm NippleEach103.95103.9520.0FalseNoneNoneFalseNoneFalse2079.00
242438972759Nonecode29Brass bib cockEach320.25320.2520.0FalseNoneNoneFalseNoneFalse6405.00
242439072759Nonecode30Supply of GI Bend 20 mm DiaEach128.1128.120.0FalseNoneNoneFalseNoneFalse2562.00
242439172759Nonecode01Geophysical investigation of site for Sinking borewell of for supplying drinking water to the habitation either through the hand pump MWS or PWSS by vertical electrical sounding by adopting venner or Schlumbergers method including reconnaissance survey of Geoological formation Geophysical investigation of exisiting ground water in the vicinity indicating the location of site recommended depth of casing pipe required to seal the top unconsolidated formation including and depth of 1.0 meter in cosolidated formation for proper seating of casing pipe depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yeild and other information required including transportation of instrument and occessories to work site engaging technical personnel and labour required etc.Each5552.45552.41.0FalseNoneNoneFalseNoneFalse5552.40
242439272759Nonecode02Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG above 1100 CMF above in all strata including over burdern. Fixing of casing pipes collars and cap with necessary cutting threading and welding including transportation of rig and supporting vehicle crew charges and cost of consumables etc. complete including yield testing at the final depth with a minimum working of compressor for one hour Excluding cost of casing pipes collars cap etc complete 0 to 50 Mtr depthMtr324.45324.4550.0FalseNoneNoneFalseNoneFalse16222.50
242439372759Nonecode03Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG above 1100 CMF above in all strata including over burdern. Fixing of casing pipes collars and cap with necessary cutting threading and welding including transportation of rig and supporting vehicle crew charges and cost of consumables etc. complete including yield testing at the final depth with a minimum working of compressor for one hour Excluding cost of casing pipes collars cap etc complete 50 to 100 Mtr depthMtr406.35406.3550.0FalseNoneNoneFalseNoneFalse20317.50
242439472759Nonecode04Cost of 160 mm dia PVC Casing pipeMtr648.9648.918.0FalseNoneNoneFalseNoneFalse11680.20
242439572759Nonecode05Supply of Bore capNo172.2172.21.0FalseNoneNoneFalseNoneFalse172.20
242439672759Nonecode06Supply of GI clamp setNo300.0300.01.0FalseNoneNoneFalseNoneFalse300.00
242439772759Nonecode07Providing, supplying to work site,Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications,with testing of as per instructions of engineer incharge of work and latest amendments. 2.00 HP/1.5KW 16 STGNo19767.319767.31.0FalseNoneNoneFalseNoneFalse19767.30
242439872759Nonecode08Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core sheathed of nominal cross sectional area as per IS 694 1990 with ISI Mark and as per its latest amendments. 1x3x2.5 Sqm.Mtr89.2589.2550.0FalseNoneNoneFalseNoneFalse4462.50
242439972759Nonecode09Providing main connection from pole PVC insulated sheathed steel wire cable in new trench as per IS 1554/ 1988 with latest amendments with ISI mark from KPTCL pole to meter board unit.Mtr141.75141.7520.0FalseNoneNoneFalseNoneFalse2835.00
242440072759Nonecode10Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia.Each3937.53937.51.0FalseNoneNoneFalseNoneFalse3937.50
242440172759Nonecode11Supply installing testing and commissioning COMMON control panel consisting of the following INCOMING1 No set of Phase indicating lamps with SFU of suitable rating 1 No Analog Ammeter 1 No Analog Voltmeter 1ni with Phase selector switch Isolating switch OUTGOING for Main Electrical Pump 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor under voltage over Volage under current over current & dry run protection suitable for the pump described above 1 no Indoor type DOLDirect Online Starter Upto 6 HP pumpsEach7875.07875.01.0FalseNoneNoneFalseNoneFalse7875.00
242440272759Nonecode12Supplying laying jointing testing and commissioning of G.I. Pipes conforming to IS 1239 1990 with latest amendments including fixing Collars Elbows Tees bends Glad Cocks and other Fittings Excluding Cost of Specials with Cuts and Threads wherever necessary including conveying the materials to workspot including testing for water tightness with all lead and lifts etc complete Contractor shall make his own arrangements for procuring water for testing Class-C HEAVY 40 mm dia GI PIPEMtr522.9522.936.0FalseNoneNoneFalseNoneFalse18824.40
242440372759Nonecode13Supplying laying jointing testing andcommissioning of G.I. Pipes conforming to IS 1239 1990 with latest amendments including fixing Collars Elbows Tees bends Glad Cocks and other Fittings Excluding Cost of Specials with Cuts and Threads wherever necessary including conveying the materials to workspot including testing for water tightness with all lead and lifts etc complete Contractor shall make his own arrangements for procuring water for testingClass-C HEAVY 20 mm dia GI PIPETapMtr276.15276.155.0FalseNoneNoneFalseNoneFalse1380.750
242440472759Nonecode14Providing wrought mild steel galvanized 15 mm dia GI collar confirming to IS 1239-II 1991 with latest amendments if any. For 40 mm dia GI collarEach216.3216.35.0FalseNoneNoneFalseNoneFalse1081.50
242440572759Nonecode15Supply and delivery at site wrought middle steel galvanized GI bend confirming to IS 1239-II 1991 with latest amendments if any For 40 mm dia GI BENDEach280.35280.352.0FalseNoneNoneFalseNoneFalse560.70
242440672759Nonecode16Supply and delivery at site wrought middle steel (galvanized) GI Socket confirming to IS 1239-II, 1991 with latest amendments if any.. For 40 mm dia GI SocketEach232.05232.052.0FalseNoneNoneFalseNoneFalse464.10
242440772759Nonecode17Supply and delivery at site wrought middle steel galvanized GI Union confirming to IS 1239-II 1991 with latest amendments if any. For 40 mm dia GI UnionEach192.15192.152.0FalseNoneNoneFalseNoneFalse384.30
242440872759Nonecode18Supply and delivery at site wrought middle steel (galvanized) GI hexagonal nipple confirming to IS 1239-II, 1991 with latest amendments if any.Each248.85248.852.0FalseNoneNoneFalseNoneFalse497.70
242440972759Nonecode19Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments Size 40 mmNo1312.51312.51.0FalseNoneNoneFalseNoneFalse1312.50
242441072759Nonecode20Cutting road surfaces for pipeline trenches and disposing of the excavated stuff as directed including barricading, danger lighting etc. in the classifications for: Cutting Cement Concrete Road surface by Machine cutting to demarcate the trench width of the surface.Cum998.55998.551.35FalseNoneNoneFalseNoneFalse1348.04250
242441172759Nonecode21Earth work excavation for pipelines/cables by Manual means upto 600mm trench width as per drawing and technical specifications including setting out shoring strutting barricading caution lights removal of stumps and other deleterious matter including dressing of excavated surfaces disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth excluding rock in trenches plinth sides of foundations etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour tools usage& other appurtenances required to complete the work.Cum508.2508.216.2FalseNoneNoneFalseNoneFalse8232.840
242441272759Nonecode22Supplying laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches laying true to line and jointing of pipes and specials with electrofusion welding giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends flanged sets bedns reducers etc. complete Contractor will make his own arrangements for procuring water for testing etc. Note Upto 110mm dia Coil shall be used. HDPE Grade -PE80 conforming to IS 4984- 1995 PN 6.0 / 6 Kg/cm2 63 mm dia.Mtr198.45198.4560.0FalseNoneNoneFalseNoneFalse11907.00
242441372759Nonecode23Refilling available earth around trenches/pipelines cables in layers not exceeding 20 cms in depth compacting each deposited layer by ramming after watering with a lead upto 50 m and lift upto 1.5 m. Including cost of all labour complete as per specifications.Cum168.0168.016.2FalseNoneNoneFalseNoneFalse2721.60
242441472759Nonecode2490X63 MM ELECTRO FUSION REDUCEREach464.1464.12.0FalseNoneNoneFalseNoneFalse928.20
242441572759Nonecode2590 MM ELECTRO FUSION TEEEach258.3258.35.0FalseNoneNoneFalseNoneFalse1291.50
242441672759Nonecode2690 MM ELECTRO FUSION COUPLEREach148.05148.055.0FalseNoneNoneFalseNoneFalse740.250
242441772759Nonecode2790 MM ELECTRO FUSION ELBOWEach259.35259.357.0FalseNoneNoneFalseNoneFalse1815.450
242441872759Nonecode2820 mm NippleEach103.95103.955.0FalseNoneNoneFalseNoneFalse519.750
242441972759Nonecode29Brass bib cockEach320.25320.255.0FalseNoneNoneFalseNoneFalse1601.250
242442072759Nonecode30Supply of GI Bend 20 mm DiaEach128.1128.15.0FalseNoneNoneFalseNoneFalse640.50
242442172759Nonecode01Geophysical investigation of site for Sinking borewell of for supplying drinking water to the habitation either through the hand pump MWS or PWSS by vertical electrical sounding by adopting venner or Schlumbergers method including reconnaissance survey of Geoological formation Geophysical investigation of exisiting ground water in the vicinity indicating the location of site recommended depth of casing pipe required to seal the top unconsolidated formation including and depth of 1.0 meter in cosolidated formation for proper seating of casing pipe depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yeild and other information required including transportation of instrument and occessories to work site engaging technical personnel and labour required etc.Each5552.45552.43.0FalseNoneNoneFalseNoneFalse16657.20
242442272759Nonecode02Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG above 1100 CMF above in all strata including over burdern. Fixing of casing pipes collars and cap with necessary cutting threading and welding including transportation of rig and supporting vehicle crew charges and cost of consumables etc. complete including yield testing at the final depth with a minimum working of compressor for one hour Excluding cost of casing pipes collars cap etc complete 0 to 50 Mtr depthMtr324.45324.45150.0FalseNoneNoneFalseNoneFalse48667.50
242442372759Nonecode03Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG above 1100 CMF above in all strata including over burdern. Fixing of casing pipes collars and cap with necessary cutting threading and welding including transportation of rig and supporting vehicle crew charges and cost of consumables etc. complete including yield testing at the final depth with a minimum working of compressor for one hour Excluding cost of casing pipes collars cap etc complete 50 to 100 Mtr depthMtr406.35406.35150.0FalseNoneNoneFalseNoneFalse60952.50
242442472759Nonecode04Cost of 160 mm dia PVC Casing pipeMtr648.9648.954.0FalseNoneNoneFalseNoneFalse35040.60
242442572759Nonecode05Supply of Bore capNo172.2172.23.0FalseNoneNoneFalseNoneFalse516.60
242442672759Nonecode06Supply of GI clamp setNo300.0300.03.0FalseNoneNoneFalseNoneFalse900.00
242442772759Nonecode07Providing, supplying to work site,Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications,with testing of as per instructions of engineer incharge of work and latest amendments. 2.00 HP/1.5KW 16 STGNo19767.319767.33.0FalseNoneNoneFalseNoneFalse59301.90
242442872759Nonecode08Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core sheathed of nominal cross sectional area as per IS 694 1990 with ISI Mark and as per its latest amendments. 1x3x2.5 Sqm.Mtr89.2589.25150.0FalseNoneNoneFalseNoneFalse13387.50
242442972759Nonecode09Providing main connection from pole PVC insulated sheathed steel wire cable in new trench as per IS 1554/ 1988 with latest amendments with ISI mark from KPTCL pole to meter board unit.Mtr141.75141.7560.0FalseNoneNoneFalseNoneFalse8505.00
242443072759Nonecode10Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia.Each3937.53937.53.0FalseNoneNoneFalseNoneFalse11812.50
242443172759Nonecode11Supply installing testing and commissioning COMMON control panel consisting of the following INCOMING1 No set of Phase indicating lamps with SFU of suitable rating 1 No Analog Ammeter 1 No Analog Voltmeter 1ni with Phase selector switch Isolating switch OUTGOING for Main Electrical Pump 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor under voltage over Volage under current over current & dry run protection suitable for the pump described above 1 no Indoor type DOLDirect Online Starter Upto 6 HP pumpsEach7875.07875.03.0FalseNoneNoneFalseNoneFalse23625.00
242443272759Nonecode12Supplying laying jointing testing and commissioning of G.I. Pipes conforming to IS 1239 1990 with latest amendments including fixing Collars Elbows Tees bends Glad Cocks and other Fittings Excluding Cost of Specials with Cuts and Threads wherever necessary including conveying the materials to workspot including testing for water tightness with all lead and lifts etc complete Contractor shall make his own arrangements for procuring water for testing Class-C HEAVY 40 mm dia GI PIPEMtr522.9522.9130.0FalseNoneNoneFalseNoneFalse67977.00
242443372759Nonecode13Supplying laying jointing testing andcommissioning of G.I. Pipes conforming to IS 1239 1990 with latest amendments including fixing Collars Elbows Tees bends Glad Cocks and other Fittings Excluding Cost of Specials with Cuts and Threads wherever necessary including conveying the materials to workspot including testing for water tightness with all lead and lifts etc complete Contractor shall make his own arrangements for procuring water for testingClass-C HEAVY 20 mm dia GI PIPETapMtr276.15276.1512.0FalseNoneNoneFalseNoneFalse3313.80
242443472759Nonecode14Providing wrought mild steel galvanized 15 mm dia GI collar confirming to IS 1239-II 1991 with latest amendments if any. For 40 mm dia GI collarEach216.3216.318.0FalseNoneNoneFalseNoneFalse3893.40
242443572759Nonecode15Supply and delivery at site wrought middle steel galvanized GI bend confirming to IS 1239-II 1991 with latest amendments if any For 40 mm dia GI BENDEach280.35280.3512.0FalseNoneNoneFalseNoneFalse3364.20
242443672759Nonecode16Supply and delivery at site wrought middle steel (galvanized) GI Socket confirming to IS 1239-II, 1991 with latest amendments if any.. For 40 mm dia GI SocketEach232.05232.056.0FalseNoneNoneFalseNoneFalse1392.30
242443772759Nonecode17Supply and delivery at site wrought middle steel galvanized GI Union confirming to IS 1239-II 1991 with latest amendments if any. For 40 mm dia GI UnionEach192.15192.156.0FalseNoneNoneFalseNoneFalse1152.90
242443872759Nonecode18Supply and delivery at site wrought middle steel (galvanized) GI hexagonal nipple confirming to IS 1239-II, 1991 with latest amendments if any.Each248.85248.8512.0FalseNoneNoneFalseNoneFalse2986.20
242443972759Nonecode19Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments Size 40 mmNo1312.51312.53.0FalseNoneNoneFalseNoneFalse3937.50
242444072759Nonecode20Cutting road surfaces for pipeline trenches and disposing of the excavated stuff as directed including barricading, danger lighting etc. in the classifications for: Cutting Cement Concrete Road surface by Machine cutting to demarcate the trench width of the surface.Cum998.55998.554.5FalseNoneNoneFalseNoneFalse4493.4750
242444172759Nonecode21Earth work excavation for pipelines/cables by Manual means upto 600mm trench width as per drawing and technical specifications including setting out shoring strutting barricading caution lights removal of stumps and other deleterious matter including dressing of excavated surfaces disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth excluding rock in trenches plinth sides of foundations etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour tools usage& other appurtenances required to complete the work.Cum508.2508.237.125FalseNoneNoneFalseNoneFalse18866.9250
242444272759Nonecode22Supplying laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches laying true to line and jointing of pipes and specials with electrofusion welding giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends flanged sets bedns reducers etc. complete Contractor will make his own arrangements for procuring water for testing etc. Note Upto 110mm dia Coil shall be used. HDPE Grade -PE80 conforming to IS 4984- 1995 PN 6.0 / 6 Kg/cm2 63 mm dia.Mtr198.45198.45275.0FalseNoneNoneFalseNoneFalse54573.750
242444372759Nonecode23Refilling available earth around trenches/pipelines cables in layers not exceeding 20 cms in depth compacting each deposited layer by ramming after watering with a lead upto 50 m and lift upto 1.5 m. Including cost of all labour complete as per specifications.Cum168.0168.037.125FalseNoneNoneFalseNoneFalse6237.00
242444472759Nonecode2490X63 MM ELECTRO FUSION REDUCEREach464.1464.13.0FalseNoneNoneFalseNoneFalse1392.30
242444572759Nonecode2590 MM ELECTRO FUSION TEEEach258.3258.310.0FalseNoneNoneFalseNoneFalse2583.00
242444672759Nonecode2690 MM ELECTRO FUSION COUPLEREach148.05148.0510.0FalseNoneNoneFalseNoneFalse1480.50
242444772759Nonecode2790 MM ELECTRO FUSION ELBOWEach259.35259.3510.0FalseNoneNoneFalseNoneFalse2593.50
242444872759Nonecode2820 mm NippleEach103.95103.9512.0FalseNoneNoneFalseNoneFalse1247.40
242444972759Nonecode29Brass bib cockEach320.25320.2512.0FalseNoneNoneFalseNoneFalse3843.00
242445072759Nonecode30Supply of GI Bend 20 mm DiaEach128.1128.112.0FalseNoneNoneFalseNoneFalse1537.20
242445172759Nonecode31Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 mCum254.1254.18.1FalseNoneNoneFalseNoneFalse2058.210
242445272759Nonecode32Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse.aggregates 2.1.1 Mix 1:5:10 Using 40 mmCum5947.25947.24.05FalseNoneNoneFalseNoneFalse24086.160
242445372759Nonecode33Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6915.76915.75.4FalseNoneNoneFalseNoneFalse37344.780
242445472759Nonecode34Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand)Cum5891.555891.559.7875FalseNoneNoneFalseNoneFalse57663.5456250
242445572759Nonecode35Providing 20 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm450.45450.4530.15FalseNoneNoneFalseNoneFalse13581.06750
242445672759Nonecode36RCC hume pipe Circular pump house: Supplying precast RCC Circular Hume pipe pump house with M.S door and RCC conical roof as per specification and drawings - Internal dia Mtr. 1200 mm & height of 2.5 Mtr. With Wall thickness 65mmEach17221.0517221.053.0FalseNoneNoneFalseNoneFalse51663.150
242445772759Nonecode37Erection and positioning of RCC Hume pipe pump house/Cistern on size stone masory platform including transportation charges and handling,finishing with all necessary tools ,plants and materials etc.,complete as directed by the Engineer in charge of the work.Each1976.11976.13.0FalseNoneNoneFalseNoneFalse5928.30
242445872759Nonecode01Geophysical investigation of site for Sinking borewell of for supplying drinking water to the habitation either through the hand pump MWS or PWSS by vertical electrical sounding by adopting venner or Schlumbergers method including reconnaissance survey of Geoological formation Geophysical investigation of exisiting ground water in the vicinity indicating the location of site recommended depth of casing pipe required to seal the top unconsolidated formation including and depth of 1.0 meter in cosolidated formation for proper seating of casing pipe depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yeild and other information required including transportation of instrument and occessories to work site engaging technical personnel and labour required etc.Each5552.45552.42.0FalseNoneNoneFalseNoneFalse11104.80
242445972759Nonecode02Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG above 1100 CMF above in all strata including over burdern. Fixing of casing pipes collars and cap with necessary cutting threading and welding including transportation of rig and supporting vehicle crew charges and cost of consumables etc. complete including yield testing at the final depth with a minimum working of compressor for one hour Excluding cost of casing pipes collars cap etc complete 0 to 50 Mtr depthMtr324.45324.45100.0FalseNoneNoneFalseNoneFalse32445.00
242446072759Nonecode03Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG above 1100 CMF above in all strata including over burdern. Fixing of casing pipes collars and cap with necessary cutting threading and welding including transportation of rig and supporting vehicle crew charges and cost of consumables etc. complete including yield testing at the final depth with a minimum working of compressor for one hour Excluding cost of casing pipes collars cap etc complete 50 to 100 Mtr depthMtr406.35406.35100.0FalseNoneNoneFalseNoneFalse40635.00
242446172759Nonecode04Cost of 160 mm dia PVC Casing pipeMtr648.9648.936.0FalseNoneNoneFalseNoneFalse23360.40
242446272759Nonecode05Supply of Bore capNo172.2172.22.0FalseNoneNoneFalseNoneFalse344.40
242446372759Nonecode06Supply of GI clamp setNo300.0300.02.0FalseNoneNoneFalseNoneFalse600.00
242446472759Nonecode07Providing, supplying to work site,Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications,with testing of as per instructions of engineer incharge of work and latest amendments. 2.00 HP/1.5KW 16 STGNo19767.319767.32.0FalseNoneNoneFalseNoneFalse39534.60
242446572759Nonecode08Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core sheathed of nominal cross sectional area as per IS 694 1990 with ISI Mark and as per its latest amendments. 1x3x2.5 Sqm.Mtr89.2589.25100.0FalseNoneNoneFalseNoneFalse8925.00
242446672759Nonecode09Providing main connection from pole PVC insulated sheathed steel wire cable in new trench as per IS 1554/ 1988 with latest amendments with ISI mark from KPTCL pole to meter board unit.Mtr141.75141.7540.0FalseNoneNoneFalseNoneFalse5670.00
242446772759Nonecode10Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia.Each3937.53937.52.0FalseNoneNoneFalseNoneFalse7875.00
242446872759Nonecode11Supply installing testing and commissioning COMMON control panel consisting of the following INCOMING1 No set of Phase indicating lamps with SFU of suitable rating 1 No Analog Ammeter 1 No Analog Voltmeter 1ni with Phase selector switch Isolating switch OUTGOING for Main Electrical Pump 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor under voltage over Volage under current over current & dry run protection suitable for the pump described above 1 no Indoor type DOLDirect Online Starter Upto 6 HP pumpsEach7875.07875.02.0FalseNoneNoneFalseNoneFalse15750.00
242446972759Nonecode12Supplying laying jointing testing and commissioning of G.I. Pipes conforming to IS 1239 1990 with latest amendments including fixing Collars Elbows Tees bends Glad Cocks and other Fittings Excluding Cost of Specials with Cuts and Threads wherever necessary including conveying the materials to workspot including testing for water tightness with all lead and lifts etc complete Contractor shall make his own arrangements for procuring water for testing Class-C HEAVY 40 mm dia GI PIPEMtr522.9522.972.0FalseNoneNoneFalseNoneFalse37648.80
242447072759Nonecode13Supplying laying jointing testing andcommissioning of G.I. Pipes conforming to IS 1239 1990 with latest amendments including fixing Collars Elbows Tees bends Glad Cocks and other Fittings Excluding Cost of Specials with Cuts and Threads wherever necessary including conveying the materials to workspot including testing for water tightness with all lead and lifts etc complete Contractor shall make his own arrangements for procuring water for testingClass-C HEAVY 20 mm dia GI PIPETapMtr276.15276.1520.0FalseNoneNoneFalseNoneFalse5523.00
242447172759Nonecode14Providing wrought mild steel galvanized 15 mm dia GI collar confirming to IS 1239-II 1991 with latest amendments if any. For 40 mm dia GI collarEach216.3216.310.0FalseNoneNoneFalseNoneFalse2163.00
242447272759Nonecode15Supply and delivery at site wrought middle steel galvanized GI bend confirming to IS 1239-II 1991 with latest amendments if any For 40 mm dia GI BENDEach280.35280.358.0FalseNoneNoneFalseNoneFalse2242.80
242447372759Nonecode16Supply and delivery at site wrought middle steel (galvanized) GI Socket confirming to IS 1239-II, 1991 with latest amendments if any.. For 40 mm dia GI SocketEach232.05232.054.0FalseNoneNoneFalseNoneFalse928.20
242447472759Nonecode17Supply and delivery at site wrought middle steel galvanized GI Union confirming to IS 1239-II 1991 with latest amendments if any. For 40 mm dia GI UnionEach192.15192.152.0FalseNoneNoneFalseNoneFalse384.30
242447572759Nonecode18Supply and delivery at site wrought middle steel (galvanized) GI hexagonal nipple confirming to IS 1239-II, 1991 with latest amendments if any.Each248.85248.854.0FalseNoneNoneFalseNoneFalse995.40
242447672759Nonecode19Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments Size 40 mmNo1312.51312.52.0FalseNoneNoneFalseNoneFalse2625.00
242447772759Nonecode20Cutting road surfaces for pipeline trenches and disposing of the excavated stuff as directed including barricading, danger lighting etc. in the classifications for: Cutting Cement Concrete Road surface by Machine cutting to demarcate the trench width of the surface.Cum998.55998.559.0FalseNoneNoneFalseNoneFalse8986.950
242447872759Nonecode21Earth work excavation for pipelines/cables by Manual means upto 600mm trench width as per drawing and technical specifications including setting out shoring strutting barricading caution lights removal of stumps and other deleterious matter including dressing of excavated surfaces disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth excluding rock in trenches plinth sides of foundations etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour tools usage& other appurtenances required to complete the work.Cum508.2508.2108.0FalseNoneNoneFalseNoneFalse54885.60
242447972759Nonecode22Supplying laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches laying true to line and jointing of pipes and specials with electrofusion welding giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends flanged sets bedns reducers etc. complete Contractor will make his own arrangements for procuring water for testing etc. Note Upto 110mm dia Coil shall be used. HDPE Grade -PE80 conforming to IS 4984- 1995 PN 6.0 / 6 Kg/cm2 63 mm dia.Mtr198.45198.45400.0FalseNoneNoneFalseNoneFalse79380.00
242448072759Nonecode23Refilling available earth around trenches/pipelines cables in layers not exceeding 20 cms in depth compacting each deposited layer by ramming after watering with a lead upto 50 m and lift upto 1.5 m. Including cost of all labour complete as per specifications.Cum168.0168.0108.0FalseNoneNoneFalseNoneFalse18144.00
242448172759Nonecode2490X63 MM ELECTRO FUSION REDUCEREach464.1464.15.0FalseNoneNoneFalseNoneFalse2320.50
242448272759Nonecode2590 MM ELECTRO FUSION TEEEach258.3258.310.0FalseNoneNoneFalseNoneFalse2583.00
242448372759Nonecode2690 MM ELECTRO FUSION COUPLEREach148.05148.0510.0FalseNoneNoneFalseNoneFalse1480.50
242448472759Nonecode2790 MM ELECTRO FUSION ELBOWEach259.35259.3515.0FalseNoneNoneFalseNoneFalse3890.250
242448572759Nonecode2820 mm NippleEach103.95103.9520.0FalseNoneNoneFalseNoneFalse2079.00
242448672759Nonecode29Brass bib cockEach320.25320.2520.0FalseNoneNoneFalseNoneFalse6405.00
242448772759Nonecode30Supply of GI Bend 20 mm DiaEach128.1128.120.0FalseNoneNoneFalseNoneFalse2562.00
242448872759Nonecode01Geophysical investigation of site for Sinking borewell of for supplying drinking water to the habitation either through the hand pump MWS or PWSS by vertical electrical sounding by adopting venner or Schlumbergers method including reconnaissance survey of Geoological formation Geophysical investigation of exisiting ground water in the vicinity indicating the location of site recommended depth of casing pipe required to seal the top unconsolidated formation including and depth of 1.0 meter in cosolidated formation for proper seating of casing pipe depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yeild and other information required including transportation of instrument and occessories to work site engaging technical personnel and labour required etc.Each5552.45552.42.0FalseNoneNoneFalseNoneFalse11104.80
242448972759Nonecode02Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG above 1100 CMF above in all strata including over burdern. Fixing of casing pipes collars and cap with necessary cutting threading and welding including transportation of rig and supporting vehicle crew charges and cost of consumables etc. complete including yield testing at the final depth with a minimum working of compressor for one hour Excluding cost of casing pipes collars cap etc complete 0 to 50 Mtr depthMtr324.45324.45100.0FalseNoneNoneFalseNoneFalse32445.00
242449072759Nonecode03Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG above 1100 CMF above in all strata including over burdern. Fixing of casing pipes collars and cap with necessary cutting threading and welding including transportation of rig and supporting vehicle crew charges and cost of consumables etc. complete including yield testing at the final depth with a minimum working of compressor for one hour Excluding cost of casing pipes collars cap etc complete 50 to 100 Mtr depthMtr406.35406.35100.0FalseNoneNoneFalseNoneFalse40635.00
242449172759Nonecode04Cost of 160 mm dia PVC Casing pipeMtr648.9648.936.0FalseNoneNoneFalseNoneFalse23360.40
242449272759Nonecode05Supply of Bore capNo172.2172.22.0FalseNoneNoneFalseNoneFalse344.40
242449372759Nonecode06Supply of GI clamp setNo300.0300.02.0FalseNoneNoneFalseNoneFalse600.00
242449472759Nonecode07Providing, supplying to work site,Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications,with testing of as per instructions of engineer incharge of work and latest amendments. 2.00 HP/1.5KW 16 STGNo19767.319767.32.0FalseNoneNoneFalseNoneFalse39534.60
242449572759Nonecode08Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core sheathed of nominal cross sectional area as per IS 694 1990 with ISI Mark and as per its latest amendments. 1x3x2.5 Sqm.Mtr89.2589.2590.0FalseNoneNoneFalseNoneFalse8032.50
242449672759Nonecode09Providing main connection from pole PVC insulated sheathed steel wire cable in new trench as per IS 1554/ 1988 with latest amendments with ISI mark from KPTCL pole to meter board unit.Mtr141.75141.7540.0FalseNoneNoneFalseNoneFalse5670.00
242449772759Nonecode10Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia.Each3937.53937.52.0FalseNoneNoneFalseNoneFalse7875.00
242449872759Nonecode11Supply installing testing and commissioning COMMON control panel consisting of the following INCOMING1 No set of Phase indicating lamps with SFU of suitable rating 1 No Analog Ammeter 1 No Analog Voltmeter 1ni with Phase selector switch Isolating switch OUTGOING for Main Electrical Pump 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor under voltage over Volage under current over current & dry run protection suitable for the pump described above 1 no Indoor type DOLDirect Online Starter Upto 6 HP pumpsEach7875.07875.02.0FalseNoneNoneFalseNoneFalse15750.00
242449972759Nonecode12Supplying laying jointing testing and commissioning of G.I. Pipes conforming to IS 1239 1990 with latest amendments including fixing Collars Elbows Tees bends Glad Cocks and other Fittings Excluding Cost of Specials with Cuts and Threads wherever necessary including conveying the materials to workspot including testing for water tightness with all lead and lifts etc complete Contractor shall make his own arrangements for procuring water for testing Class-C HEAVY 40 mm dia GI PIPEMtr522.9522.980.0FalseNoneNoneFalseNoneFalse41832.00
242450072759Nonecode13Supplying laying jointing testing andcommissioning of G.I. Pipes conforming to IS 1239 1990 with latest amendments including fixing Collars Elbows Tees bends Glad Cocks and other Fittings Excluding Cost of Specials with Cuts and Threads wherever necessary including conveying the materials to workspot including testing for water tightness with all lead and lifts etc complete Contractor shall make his own arrangements for procuring water for testingClass-C HEAVY 20 mm dia GI PIPETapMtr276.15276.1510.0FalseNoneNoneFalseNoneFalse2761.50
242450172759Nonecode14Providing wrought mild steel galvanized 15 mm dia GI collar confirming to IS 1239-II 1991 with latest amendments if any. For 40 mm dia GI collarEach216.3216.36.0FalseNoneNoneFalseNoneFalse1297.80
242450272759Nonecode15Supply and delivery at site wrought middle steel galvanized GI bend confirming to IS 1239-II 1991 with latest amendments if any For 40 mm dia GI BENDEach280.35280.354.0FalseNoneNoneFalseNoneFalse1121.40
242450372759Nonecode16Supply and delivery at site wrought middle steel (galvanized) GI Socket confirming to IS 1239-II, 1991 with latest amendments if any.. For 40 mm dia GI SocketEach232.05232.054.0FalseNoneNoneFalseNoneFalse928.20
242450472759Nonecode17Supply and delivery at site wrought middle steel galvanized GI Union confirming to IS 1239-II 1991 with latest amendments if any. For 40 mm dia GI UnionEach192.15192.154.0FalseNoneNoneFalseNoneFalse768.60
242450572759Nonecode18Supply and delivery at site wrought middle steel (galvanized) GI hexagonal nipple confirming to IS 1239-II, 1991 with latest amendments if any.Each248.85248.854.0FalseNoneNoneFalseNoneFalse995.40
242450672759Nonecode19Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments Size 40 mmNo1312.51312.52.0FalseNoneNoneFalseNoneFalse2625.00
242450772759Nonecode20Earth work excavation for pipelines/cables by Manual means upto 600mm trench width as per drawing and technical specifications including setting out shoring strutting barricading caution lights removal of stumps and other deleterious matter including dressing of excavated surfaces disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth excluding rock in trenches plinth sides of foundations etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour tools usage& other appurtenances required to complete the work.Cum508.2508.29.45FalseNoneNoneFalseNoneFalse4802.490
242450872759Nonecode21Supplying laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches laying true to line and jointing of pipes and specials with electrofusion welding giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends flanged sets bedns reducers etc. complete Contractor will make his own arrangements for procuring water for testing etc. Note Upto 110mm dia Coil shall be used. HDPE Grade -PE80 conforming to IS 4984- 1995 PN 6.0 / 6 Kg/cm2 63 mm dia.Mtr198.45198.4535.0FalseNoneNoneFalseNoneFalse6945.750
242450972759Nonecode22Refilling available earth around trenches/pipelines cables in layers not exceeding 20 cms in depth compacting each deposited layer by ramming after watering with a lead upto 50 m and lift upto 1.5 m. Including cost of all labour complete as per specifications.Cum168.0168.09.45FalseNoneNoneFalseNoneFalse1587.60
242451072759Nonecode2320 mm NippleEach103.95103.9510.0FalseNoneNoneFalseNoneFalse1039.50
242451172759Nonecode24Brass bib cockEach320.25320.2510.0FalseNoneNoneFalseNoneFalse3202.50
242451272759Nonecode25Supply of GI Bend 20 mm DiaEach128.1128.15.0FalseNoneNoneFalseNoneFalse640.50
242451372759Nonecode26Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 mCum254.1254.12.7FalseNoneNoneFalseNoneFalse686.070
242451472759Nonecode27Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse.aggregates 2.1.1 Mix 1:5:10 Using 40 mmCum5947.25947.21.35FalseNoneNoneFalseNoneFalse8028.720
242451572759Nonecode28Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6915.76915.71.8FalseNoneNoneFalseNoneFalse12448.260
242451672759Nonecode29Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand)Cum5891.555891.553.2625FalseNoneNoneFalseNoneFalse19221.1818750
242451772759Nonecode30Providing 20 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm450.45450.4510.05FalseNoneNoneFalseNoneFalse4527.02250
242451872759Nonecode31RCC hume pipe Circular pump house: Supplying precast RCC Circular Hume pipe pump house with M.S door and RCC conical roof as per specification and drawings - Internal dia Mtr. 1200 mm & height of 2.5 Mtr. With Wall thickness 65mmEach17221.0517221.051.0FalseNoneNoneFalseNoneFalse17221.050
242451972759Nonecode32Erection and positioning of RCC Hume pipe pump house/Cistern on size stone masory platform including transportation charges and handling,finishing with all necessary tools ,plants and materials etc.,complete as directed by the Engineer in charge of the work.Each1976.11976.11.0FalseNoneNoneFalseNoneFalse1976.10
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17069629750000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17069629750000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17069629750000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17069629750000NoneNoneELIGIBILITYMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)None
17069629750000NoneNoneELIGIBILITYSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)None
17069629750000NoneNoneELIGIBILITYTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNone
17069629750000NoneNoneELIGIBILITYTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNone
17069629750000NoneNoneELIGIBILITYTotal value of civl engineering works executed and payments received in the last five years (year-wise)None
17069629750000NoneNoneELIGIBILITYList of existing commitments and ongoing worksNone
17069629750000NoneNoneELIGIBILITYList of works for which tenders already submittedNone
17069629750000NoneNoneELIGIBILITYBanker Details for referenceNone
17069629750000NoneNoneELIGIBILITYConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNone
17069629750000NoneNoneELIGIBILITYReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNone
17069629750000NoneNoneELIGIBILITYQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNone
17069629750000NoneNoneELIGIBILITYProposals for subcontracting components of works amounting to more than 20% of the contract price (for each, the qualifications and experience of the identified sub-contractor in the relevant fields should be attached)None
preQualCriterionListNone
technicalCriterionListNone
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Qualification A To qualify award of this contract each tenderer in his name should have in the last five years period a. achieved in at least two financial years an average annual financial turnover of Estimate CostTrueTechnical Bid
PWD Registration CertificateTrueTechnical Bid
GST and PANTrueTechnical Bid
Mandatory Satisfactory completion as a prime contractor for at least 1 civil work 50per of total cost of works. Attested by Executive EngineerTrueTechnical Bid
EPF Certificate and ClearanceTrueTechnical Bid
Liquid assets and /or availability of credit facilities of not less than amount Rs. 7.02 lakhs Attach Credit lines/ letter of credit/ Banker certificates Unconditional issued by scheduled banks.TrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone