2446352 | 73730 | None | VJP01 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth | Cum | 97.85 | 97.85 | 187.5 | False | None | None | False | None | False | 18346.875 | 0 |
2446353 | 73730 | None | VJP02 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work1.14.1 In all kinds of soils Depth upto 3 m | Cum | 105.06 | 105.06 | 143.21 | False | None | None | False | None | False | 15045.6426 | 0 |
2446354 | 73730 | None | VJP03 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work in ordinary/soft rock without blasting upto 1.5 m depth | Cum | 373.89 | 373.89 | 68.83 | False | None | None | False | None | False | 25734.8487 | 0 |
2446355 | 73730 | None | VJP04 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.(Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates) | Cum | 5833.92 | 5833.92 | 9.25 | False | None | None | False | None | False | 53963.76 | 0 |
2446356 | 73730 | None | VJP05 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.(Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates) | Cum | 6168.67 | 6168.67 | 37.85 | False | None | None | False | None | False | 233484.1595 | 0 |
2446357 | 73730 | None | VJP06 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RCC for Footing (Including 8% for Centering) | Cum | 7048.17 | 7048.17 | 21.18 | False | None | None | False | None | False | 149280.2406 | 0 |
2446358 | 73730 | None | VJP07 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RCC for Columns (Including 70% for Centering) | Cum | 11346.48 | 11346.48 | 9.83 | False | None | None | False | None | False | 111535.8984 | 0 |
2446359 | 73730 | None | VJP08 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RCC for Retaining wall (Including 10% for Centering) | Cum | 7341.84 | 7341.84 | 17.94 | False | None | None | False | None | False | 131712.6096 | 0 |
2446360 | 73730 | None | VJP09 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RCC for slab (Including 45% for Centering) | Cum | 9677.88 | 9677.88 | 17.94 | False | None | None | False | None | False | 173621.1672 | 0 |
2446361 | 73730 | None | VJP10 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RCC for PB (Including 50% for Centering) | Cum | 10011.6 | 10011.6 | 27.52 | False | None | None | False | None | False | 275519.232 | 0 |
2446362 | 73730 | None | VJP11 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 273.98 | 273.98 | 171.78 | False | None | None | False | None | False | 47064.2844 | 0 |
2446363 | 73730 | None | VJP12 | Construction of Embankment by excavating the available approved Gravel/ Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. | Cum | 488.22 | 488.22 | 203.52 | False | None | None | False | None | False | 99362.5344 | 0 |
2446364 | 73730 | None | VJP13 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. | Tonne | 92140.71 | 92140.71 | 10.21 | False | None | None | False | None | False | 940756.6491 | 0 |
2446365 | 73730 | None | VJP14 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. | Kg | 188.49 | 188.49 | 150.0 | False | None | None | False | None | False | 28273.5 | 0 |
2446366 | 73730 | None | VJP15 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineerin- Charge. | Kg | 142.14 | 142.14 | 90.0 | False | None | None | False | None | False | 12792.6 | 0 |
2446367 | 73730 | None | VJP16 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 118.45 | 118.45 | 16.5 | False | None | None | False | None | False | 1954.425 | 0 |
2446368 | 73730 | None | VJP17 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 2711.99 | 2711.99 | 16.5 | False | None | None | False | None | False | 44747.835 | 0 |
2446369 | 73730 | None | VJP18 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diamete | m | 299.73 | 299.73 | 47.5 | False | None | None | False | None | False | 14237.175 | 0 |
2446370 | 73730 | None | VJP19 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates) | Cum | 6512.69 | 6512.69 | 50.42 | False | None | None | False | None | False | 328369.8298 | 0 |
2446371 | 73730 | None | VJP20 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings,brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in Charge. | Kg | 140.08 | 140.08 | 2896.69 | False | None | None | False | None | False | 405768.3352 | 0 |
2446372 | 73730 | None | VJP21 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings,brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in Charge. (1% lift charges) | Kg | 141.48 | 141.48 | 2652.72 | False | None | None | False | None | False | 375306.8256 | 0 |
2446373 | 73730 | None | VJP22 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings,brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in Charge. (2% lift charges) | Kg | 142.88 | 142.88 | 13854.59 | False | None | None | False | None | False | 1979543.8192 | 0 |
2446374 | 73730 | None | VJP23 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (2 % lift Charges) | Sqm | 596.74 | 596.74 | 836.75 | False | None | None | False | None | False | 499322.195 | 0 |
2446375 | 73730 | None | VJP24 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges plain (500 - 600mm) | m | 464.53 | 464.53 | 20.9 | False | None | None | False | None | False | 9708.677 | 0 |
2446376 | 73730 | None | VJP25 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Flashings/ Aprons ( Upto 600 mm) | m | 425.39 | 425.39 | 74.26 | False | None | None | False | None | False | 31589.4614 | 0 |
2446377 | 73730 | None | VJP26 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Gutter (600 mm over all girth) | m | 1106.22 | 1106.22 | 74.26 | False | None | None | False | None | False | 82147.8972 | 0 |
2446378 | 73730 | None | VJP27 | Finishing with Epoxy paint (two coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Enginer-in-charge. | Sqm | 181.28 | 181.28 | 1361.28 | False | None | None | False | None | False | 246772.8384 | 0 |
2446379 | 73730 | None | VJP28 | Insulation & Refrigerator System | Each | 6410451.0 | 6410451.0 | 1.0 | False | None | None | False | None | False | 6410451.0 | 0 |
2446380 | 73730 | None | VJP29 | Heavy Duty Mezzanine Floor and Staircase with Hand Railing ( G + 2 Levels ) | Each | 3830000.0 | 3830000.0 | 1.0 | False | None | None | False | None | False | 3830000.0 | 0 |
2446381 | 73730 | None | VJP30 | Goods Lift - Wire Rope Drum Type Hoist for 2 floors. | Each | 1100000.0 | 1100000.0 | 1.0 | False | None | None | False | None | False | 1100000.0 | 0 |
2446382 | 73730 | None | VJP31 | Concealed Conduit System
Supplying heavy gauge PVC conduit pipe ........mm dia.......mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary 19/20mm die 2mm thick | Per Mtr | 67.98 | 67.98 | 100.0 | False | None | None | False | None | False | 6798.0 | 0 |
2446383 | 73730 | None | VJP32 | Concealed Conduit System
Supplying heavy gauge PVC conduit pipe ........mm dia.......mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) - a) 25 mm dia 2 mm thick | Per Mtr | 80.34 | 80.34 | 100.0 | False | None | None | False | None | False | 8034.0 | 0 |
2446384 | 73730 | None | VJP33 | Supplying heavy gauge PVC conduit pipe ........mm dia.......mm thick with suitable size bends, metal/PVC junction boxes adhesive paste etc.,by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19/20mm dia 2mm thick | Per Mtr | 70.04 | 70.04 | 90.0 | False | None | None | False | None | False | 6303.6 | 0 |
2446385 | 73730 | None | VJP34 | Supplying heavy gauge PVC conduit pipe ........mm dia.......mm thick with suitable size bends, metal/PVC junction boxes adhesive paste etc.,by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 25mm dia 2mm thick | Per Mtr | 81.37 | 81.37 | 60.0 | False | None | None | False | None | False | 4882.2 | 0 |
2446386 | 73730 | None | VJP35 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments)without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet short Point | Point | 277.07 | 277.07 | 6.0 | False | None | None | False | None | False | 1662.42 | 0 |
2446387 | 73730 | None | VJP36 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. 3 Mtr up to 6Mtr from tapping point to out let via switch | Point | 390.37 | 390.37 | 6.0 | False | None | None | False | None | False | 2342.22 | 0 |
2446388 | 73730 | None | VJP37 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. t. Group - A. Long point a above 6 Mtr up to 10Mtr from tapping point to out let via switch | Point | 571.65 | 571.65 | 12.0 | False | None | None | False | None | False | 6859.8 | 0 |
2446389 | 73730 | None | VJP38 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper conductor resistance single core wire in open or consealed system of wiring with specified IS- 694:1990 & confirming to GTP of Group - A.1.0sqmm. | Per Mtr | 19.57 | 19.57 | 200.0 | False | None | None | False | None | False | 3914.0 | 0 |
2446390 | 73730 | None | VJP39 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper conductor resistance single core wire in open or consealed system of wiring with specified IS- 694:1990 & confirming to GTP of Group - A.2.5sqmm. | Per Mtr | 43.26 | 43.26 | 400.0 | False | None | None | False | None | False | 17304.0 | 0 |
2446391 | 73730 | None | VJP40 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper conductor resistance single core wire in open or consealed system of wiring with specified IS- 694:1990 & confirming to GTP of Group - A.4.0sqmm. | Per Mtr | 64.89 | 64.89 | 200.0 | False | None | None | False | None | False | 12978.0 | 0 |
2446392 | 73730 | None | VJP41 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall..1-3Way | Each | 163.77 | 163.77 | 4.0 | False | None | None | False | None | False | 655.08 | 0 |
2446393 | 73730 | None | VJP42 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall..4-5Way | Each | 182.31 | 182.31 | 1.0 | False | None | None | False | None | False | 182.31 | 0 |
2446394 | 73730 | None | VJP43 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall..6Way | Each | 226.6 | 226.6 | 2.0 | False | None | None | False | None | False | 453.2 | 0 |
2446395 | 73730 | None | VJP44 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall..8Way | Each | 268.83 | 268.83 | 4.0 | False | None | None | False | None | False | 1075.32 | 0 |
2446396 | 73730 | None | VJP45 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall..10-12Way | Each | 328.57 | 328.57 | 1.0 | False | None | None | False | None | False | 328.57 | 0 |
2446397 | 73730 | None | VJP46 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box...1 to 3 Module | Each | 165.83 | 165.83 | 4.0 | False | None | None | False | None | False | 663.32 | 0 |
2446398 | 73730 | None | VJP47 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box..4 Module | Each | 180.25 | 180.25 | 1.0 | False | None | None | False | None | False | 180.25 | 0 |
2446399 | 73730 | None | VJP48 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box..6 Module | Each | 241.02 | 241.02 | 2.0 | False | None | None | False | None | False | 482.04 | 0 |
2446400 | 73730 | None | VJP49 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box..8 Module | Each | 292.52 | 292.52 | 4.0 | False | None | None | False | None | False | 1170.08 | 0 |
2446401 | 73730 | None | VJP50 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box..12 Module | Each | 354.32 | 354.32 | 1.0 | False | None | None | False | None | False | 354.32 | 0 |
2446402 | 73730 | None | VJP51 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch | Each | 105.06 | 105.06 | 40.0 | False | None | None | False | None | False | 4202.4 | 0 |
2446403 | 73730 | None | VJP52 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6Amps Two way Switch | Each | 170.98 | 170.98 | 3.0 | False | None | None | False | None | False | 512.94 | 0 |
2446404 | 73730 | None | VJP53 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6Amps 3way socket | Each | 176.13 | 176.13 | 10.0 | False | None | None | False | None | False | 1761.3 | 0 |
2446405 | 73730 | None | VJP54 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 16Amps one way switch | Each | 185.4 | 185.4 | 3.0 | False | None | None | False | None | False | 556.2 | 0 |
2446406 | 73730 | None | VJP55 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 32Amps DP switch | Each | 335.78 | 335.78 | 3.0 | False | None | None | False | None | False | 1007.34 | 0 |
2446407 | 73730 | None | VJP56 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6/16Amps universal socket | Each | 243.08 | 243.08 | 3.0 | False | None | None | False | None | False | 729.24 | 0 |
2446408 | 73730 | None | VJP57 | Supplying & Fixing of 70-150 Watts lamp holder 2 Pin | No | 64.89 | 64.89 | 1.0 | False | None | None | False | None | False | 64.89 | 0 |
2446409 | 73730 | None | VJP58 | Supplying & fixing retrofit type -PL- LED Lamp .......W LED linear source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit rotection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.8-9 Watts | Each | 723.06 | 723.06 | 1.0 | False | None | None | False | None | False | 723.06 | 0 |
2446410 | 73730 | None | VJP59 | Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fighting 1 x4'- 20/22 w | Each | 710.7 | 710.7 | 6.0 | False | None | None | False | None | False | 4264.2 | 0 |
2446411 | 73730 | None | VJP60 | Supplying of recess mounting non integral type ........ LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per W, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.LED modular down light 1'x4' 34-36W | Each | 6074.94 | 6074.94 | 10.0 | False | None | None | False | None | False | 60749.4 | 0 |
2446412 | 73730 | None | VJP61 | Supplying of on load change over switches 4 poles,AC-23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM Enclosure Sheet Metal Execution) 630 Amps | Each | 39186.35 | 39186.35 | 1.0 | False | None | None | False | None | False | 39186.35 | 0 |
2446413 | 73730 | None | VJP62 | Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 40 Amps | Each | 4212.7 | 4212.7 | 1.0 | False | None | None | False | None | False | 4212.7 | 0 |
2446414 | 73730 | None | VJP63 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. ( Icu = Ics) FOUR POLE 100Amps 25kA. | Each | 8741.61 | 8741.61 | 1.0 | False | None | None | False | None | False | 8741.61 | 0 |
2446415 | 73730 | None | VJP64 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. ( Icu = Ics) FOUR POLE500-630Amps 50kA. | Each | 43155.97 | 43155.97 | 3.0 | False | None | None | False | None | False | 129467.91 | 0 |
2446416 | 73730 | None | VJP65 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32Amps SP | Each | 427.45 | 427.45 | 8.0 | False | None | None | False | None | False | 3419.6 | 0 |
2446417 | 73730 | None | VJP66 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 Amps DP | Each | 761.17 | 761.17 | 2.0 | False | None | None | False | None | False | 1522.34 | 0 |
2446418 | 73730 | None | VJP67 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.40 Amps TPN | Each | 3180.64 | 3180.64 | 1.0 | False | None | None | False | None | False | 3180.64 | 0 |
2446419 | 73730 | None | VJP68 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure.12Way SP &N | Each | 2398.87 | 2398.87 | 1.0 | False | None | None | False | None | False | 2398.87 | 0 |
2446420 | 73730 | None | VJP69 | Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 16SWG | Sq CM | 0.44 | 0.44 | 100000.0 | False | None | None | False | None | False | 44000.0 | 0 |
2446421 | 73730 | None | VJP70 | Supplying, fixing and wiring Automatic Power Factor controller circuit unit fully, static units controlled by 14 stage microprocessor operation, relays LED display, self programming function for power stages and operating logic checking facility for healthy and efficient of each individual capacitor bank, measurement of network harmonics with indication when limit values are exceeded, Comprehensive displays with large, three phase LED display, Long term memory for settings, protection for over voltage, power factor correction fault and no voltage, to connect / disconnect banks, with automatic recognition or with standard programs. | Each | 22289.2 | 22289.2 | 1.0 | False | None | None | False | None | False | 22289.2 | 0 |
2446422 | 73730 | None | VJP71 | Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 600Amps 4x75x10mm Aluminium Strips | Mtr | 5793.75 | 5793.75 | 5.0 | False | None | None | False | None | False | 28968.75 | 0 |
2446423 | 73730 | None | VJP72 | Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH, KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy. | Each | 9594.45 | 9594.45 | 1.0 | False | None | None | False | None | False | 9594.45 | 0 |
2446424 | 73730 | None | VJP73 | Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound. | Each | 578.86 | 578.86 | 2.0 | False | None | None | False | None | False | 1157.72 | 0 |
2446425 | 73730 | None | VJP74 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440v A.C. 50 Hz 12/24v D.C. | Each | 530.45 | 530.45 | 3.0 | False | None | None | False | None | False | 1591.35 | 0 |
2446426 | 73730 | None | VJP75 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 50x50x6mm | Mtr | 406.85 | 406.85 | 10.0 | False | None | None | False | None | False | 4068.5 | 0 |
2446427 | 73730 | None | VJP76 | Supplying and fixing Microprocessor Based Astronomical timer Switch with using necessary bolts, nuts and washers. | Each | 4988.29 | 4988.29 | 1.0 | False | None | None | False | None | False | 4988.29 | 0 |
2446428 | 73730 | None | VJP77 | Earth work excavation for pipeline trenches in all kinds of soils by mechanical
means as per drawing and technical specifications, including setting out,
construction of shoring, strutting, barricading, caution lights, bracing, using
sight rails & bonding rods at every 100 mm wherever necessary as directed,
removal of stumps and other deleterious matter, dressing of sides and levelling
the bottom of trench to the extent required , utilising the available excavated
earth locally for the work etc., and all other appurtenances complete in the
following strataIn soil (ordinary) | Cum | 269.86 | 269.86 | 40.0 | False | None | None | False | None | False | 10794.4 | 0 |
2446429 | 73730 | None | VJP78 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 240 Sqmm, 3.5 Core, (30 GI Strips - 4 x 0.8 mm)(From L.T.Distribution Box To Main Panel) | Km | 888545.98 | 888545.98 | 0.16 | False | None | None | False | None | False | 142167.3568 | 0 |
2446430 | 73730 | None | VJP79 | Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe / stoneware pipe / on wall / on pole as required. In existing trench/duct. 185sqmm to 240Sqmm | Km | 33246.34 | 33246.34 | 0.16 | False | None | None | False | None | False | 5319.4144 | 0 |
2446431 | 73730 | None | VJP80 | Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour complete as per specifications | Cum | 164.8 | 164.8 | 40.0 | False | None | None | False | None | False | 6592.0 | 0 |
2446432 | 73730 | None | VJP81 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia
2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification
7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia | Nos | 3685.5 | 3685.5 | 4.0 | False | None | None | False | None | False | 14742.0 | 0 |
2446433 | 73730 | None | VJP82 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. 13.7.1 On wall / ceiling / Rafter / Girders | Each | 125.66 | 125.66 | 16.0 | False | None | None | False | None | False | 2010.56 | 0 |
2446434 | 73730 | None | VJP83 | Supply and installation of 2 Kg C02 Gas Type Fire Extinugisher Squeeze grip type, used Unused Mechanism, Squeeze Grip, Gross Weight 9.1 Kg. empty Weight 7.1 Kg. Can Height 595MM Diameter 108MM, Discharge Time less than 8 Sees, Controllable discharge mechanism, Applicable on Class 8&C Fire, 8 Rating 88, Can Construction : Hot spinning/Forging, Valve Construction : Forging & Machining, Internal Coating of Can : Not Applicable, External coating of Can : Spray Painting, Sheet metal thickness: 4.0MM lSI Approved, 1 Year Warranty.with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost cost of supporting materials like MS stand & accessaries if it is fixing n floor / MS brackets & accessories if it is fixing on wall,, labour, usage charges of machinery complete as per specifications. complete | Each | 2237.16 | 2237.16 | 6.0 | False | None | None | False | None | False | 13422.96 | 0 |
2446435 | 73730 | None | VJP84 | Caution/Danger Board | Each | 125.66 | 125.66 | 6.0 | False | None | None | False | None | False | 753.96 | 0 |
2446436 | 73730 | None | VJP85 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency1301m/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source.LED Streetlight 70W | Each | 6171.76 | 6171.76 | 4.0 | False | None | None | False | None | False | 24687.04 | 0 |
2446437 | 73730 | None | VJP86 | Supplying and Fixing of........mm dia class A GI pipe bracket upto 2 ms long bent at suitable angle and fixing to this bracket street light fitting of all capacities to GI or GI or rail or RCC pole / wall using suitable clamps, bolts, and nuts and wiring using suitable capacity wires.Using 32mm dia G.I.Pipe | Each | 1076.35 | 1076.35 | 4.0 | False | None | None | False | None | False | 4305.4 | 0 |
2446438 | 73730 | None | VJP87 | Providing 2 Pole Structrue at the Tapping Point Using RCC Pole using 9 mtr RCC Pole Complete set | Each | 67811.08 | 67811.08 | 2.0 | False | None | None | False | None | False | 135622.16 | 0 |
2446439 | 73730 | None | VJP88 | RCC Pole - 9 Mtr Long, 145 Kg WL (Dwg No. BESCOM/GM/QS&S/02 Dtd 24.11.2018) | Nos | 7429.8 | 7429.8 | 2.0 | False | None | None | False | None | False | 14859.6 | 0 |
2446440 | 73730 | None | VJP89 | PSCC Pole - 9 Mtr Long, 200 Kg WL (Dwg No. BESCOM/GM/QS&S/50 Dtd 24.11.2018) as per REC Standards | Nos | 4408.95 | 4408.95 | 4.0 | False | None | None | False | None | False | 17635.8 | 0 |
2446441 | 73730 | None | VJP90 | 11 kV, Horizontal Cross Arm - Galvanised Iron (GI) | Nos | 511.35 | 511.35 | 6.0 | False | None | None | False | None | False | 3068.1 | 0 |
2446442 | 73730 | None | VJP91 | 11 kV, Special 3 Pin Cross Arm - GI | Nos | 1208.55 | 1208.55 | 18.0 | False | None | None | False | None | False | 21753.9 | 0 |
2446443 | 73730 | None | VJP92 | Insulator as per IS-1445 for Ceremic, IS-7935 for GI Pin, IEC-61109 for Polymeric DISC Insulator 45 kN Porcelain | Nos | 535.5 | 535.5 | 12.0 | False | None | None | False | None | False | 6426.0 | 0 |
2446444 | 73730 | None | VJP93 | ACSR Conductor as per IS-398 (Part - 2/1996) Rabbit ACSR | Km | 48545.7 | 48545.7 | 1.0 | False | None | None | False | None | False | 48545.7 | 0 |
2446445 | 73730 | None | VJP94 | Guy Wire & GI Wire as per IS-2141 8 SWG GI Wire 281008 | MT | 78792.0 | 78792.0 | 0.05 | False | None | None | False | None | False | 3939.6 | 0 |
2446446 | 73730 | None | VJP95 | Erection of RCC/PSCC Pole of 9 to 10 Mtr long in a pit of 1.8 Mtr depth | Each | 1168.65 | 1168.65 | 6.0 | False | None | None | False | None | False | 7011.9 | 0 |
2446447 | 73730 | None | VJP96 | LT Distribution Box for 100 kVA DTC with MCCB's (Sheet Metal)
(Dwg No. BESCOM/GM/QS&S/58 Dtd 24.11.2018) | Nos | 23954.7 | 23954.7 | 1.0 | False | None | None | False | None | False | 23954.7 | 0 |
2446448 | 73730 | None | VJP97 | Distribution Transformer - 3 Phase, 11kV/433V - Stacked CRGO Core with Oil as per IS-1180 (Part-1): 2014 100 kVA, Aluminium Wdg, Star 2 (5 Star) | Each | 558977.0 | 558977.0 | 1.0 | False | None | None | False | None | False | 558977.0 | 0 |
2446449 | 73730 | None | VJP98 | 11 kV HT Metering cubicle of different CT Ratio, Both side cable entry type with 3 CT & 3 PT, With Transparent Cover TTB, with 30x8 mm Copper Busbar, Modem & 2 No of Meters for 3 Phase 4 Wire Metering without Load Break Switch (HT Metering Box Fabricated out of 3 mm MS Sheet duly epoxy powder coated) as per revised Specification
(Dwg No. BESCOM/GM/QS&S/-- Dtd 24.11.2018) | Each | 255645.6 | 255645.6 | 1.0 | False | None | None | False | None | False | 255645.6 | 0 |
2446450 | 73730 | None | VJP99 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. GI strip 25x6mm | Mtr | 84.46 | 84.46 | 60.0 | False | None | None | False | None | False | 5067.6 | 0 |
2446451 | 73730 | None | VJP100 | Construction of platform with size stone, cement concert for erection of 500 kVA Transformer/Metering cubicle/Heavy Equipment. Construction of platform (1.5x1.5x1.2) Mtr in size stone, for erection of transformers/Heavy equipment including all materials, labour. Excavation of (1.5x1.5x1) Mtr pit for foundation providing and laying cement concrete 1:4:8 for foundation laid in 10 cm thick layers, well compacted curing etc., complete providing and construction of stone masonary 0.9 Mtr below ground level and 1.2 Mtr above ground level neatly hammer dressed in cement morter 1:6. Providing and Laying cement concrete slab 1.5x1.5x0.10 Mtr with cement concrete of 1:2:4 mix forming & cutting complete, providing pointing to stone masonary in cement morter 1:3 after racking joint & nisely lining curing etc., plastering the concrete surfaces in cement morter 1:4 including smooth randering curing etc., curing at every stages completely. | Nos | 31271.83 | 31271.83 | 5.0 | False | None | None | False | None | False | 156359.15 | 0 |
2446452 | 73730 | None | VJP101 | HT Cable GROUP A: Supplying and laying of high tension 11KV cable, Dry Curing & Dry Cooling with true triple extrusion, simultaneously through a single common head, 3 core under ground XLPE (E) cable having stranded compact circular aluminium conductor, screened insulated, insulation screened with extruded semiconducting compound in combination with copper tape, core laid up extruded inner sheathed of GI flat strip armoured and overall PVC sheathed with specified IS 7098/11/85 with latest amendments & confirming to the GTP of GROUP-A3Cx95sqmm | Km | 916355.98 | 916355.98 | 0.08 | False | None | None | False | None | False | 73308.4784 | 0 |
2446453 | 73730 | None | VJP102 | Earth work excavation for pipeline trenches in all kinds of soils by mechanical
means as per drawing and technical specifications, including setting out,
construction of shoring, strutting, barricading, caution lights, bracing, using
sight rails & bonding rods at every 100 mm wherever necessary as directed,
removal of stumps and other deleterious matter, dressing of sides and levelling
the bottom of trench to the extent required , utilising the available excavated
earth locally for the work etc., and all other appurtenances complete in the
following strata In soil (ordinary) | Cum | 269.86 | 269.86 | 40.0 | False | None | None | False | None | False | 10794.4 | 0 |
2446454 | 73730 | None | VJP103 | Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour complete as per specifications | Cum | 164.8 | 164.8 | 40.0 | False | None | None | False | None | False | 6592.0 | 0 |
2446455 | 73730 | None | VJP104 | Spreading and forming with sand all round the cable to a depth of 75 mm and width of 500 mm. (Does not include cost of sand). | Km | 15550.5 | 15550.5 | 0.6 | False | None | None | False | None | False | 9330.3 | 0 |
2446456 | 73730 | None | VJP105 | Supplying at site Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. etc. complete. .00 1 | Kg | 116.39 | 116.39 | 40.0 | False | None | None | False | None | False | 4655.6 | 0 |
2446457 | 73730 | None | VJP106 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size 25x25 mm made of G.I. wire of dia 3 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. | Sqm | 919.79 | 919.79 | 60.0 | False | None | None | False | None | False | 55187.4 | 0 |
2446458 | 73730 | None | VJP107 | Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40 mm dia 2.9 mm thick 2.5m long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400 mm with a cast iron cover. The earth electrode shall have staggered holes of 12 mm dia and the electrode should be covered 150 mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts. | No | 4383.68 | 4383.68 | 10.0 | False | None | None | False | None | False | 43836.8 | 0 |
2446459 | 73730 | None | VJP108 | Solar Photovoltaic Power Plant Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:- a) Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. c) Data Monitoring System complete with accessories. d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. e) Lightning and surge voltage protection. f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required. Genset Controller: microprocessor based generator set monitoring and control system. The control provides a simple operator interface to the generator set, manual and remote start/ stop control, shutdown fault indication, and an LCD hour counter. The integration of all functions into a single control system provides enhanced reliability and performance compared to conventional generator set control systems. This control has been designed and tested to meet harsh environment in which gensets are typically applied. Features, Functions, protections 16 character x 2 line alphanumeric LCD display with LED Backlight | No | 62891.8 | 62891.8 | 7.0 | False | None | None | False | None | False | 440242.6 | 0 |
2446460 | 73730 | None | VJP109 | Load Break Switch with Panel | Unit | 75436.17 | 75436.17 | 1.0 | False | None | None | False | None | False | 75436.17 | 0 |
2446461 | 73730 | None | VJP110 | Supplying of four bucket stand alongwith buckets. Complete | Each | 1905.5 | 1905.5 | 5.0 | False | None | None | False | None | False | 9527.5 | 0 |
2446462 | 73730 | None | VJP111 | Supplying of Hand gloves. complete | Each | 1004.25 | 1004.25 | 6.0 | False | None | None | False | None | False | 6025.5 | 0 |
2446463 | 73730 | None | VJP112 | Supplying of first aid box. complete | Each | 618.0 | 618.0 | 4.0 | False | None | None | False | None | False | 2472.0 | 0 |
2446464 | 73730 | None | VJP113 | Supplying of SAFETY MASK. complete | Each | 154.5 | 154.5 | 3.0 | False | None | None | False | None | False | 463.5 | 0 |
2446465 | 73730 | None | VJP114 | Supplying of FIRST AID CHART with lamination. Complete | Each | 412.0 | 412.0 | 3.0 | False | None | None | False | None | False | 1236.0 | 0 |
2446466 | 73730 | None | VJP115 | Supplying and installation of RUBBER MAT 1mtr x 1mtr -1Omm thick.
complete including cost of materials, labour, usage charges of machinery complete as per specifications. | Each | 1957.0 | 1957.0 | 4.0 | False | None | None | False | None | False | 7828.0 | 0 |
2446467 | 73730 | None | VJP116 | Erection, alignment and fixing to the foundation, indoor/outdoor 11KV switchgear panel/unit including movement from the point of unloading to the point of erction. 331 41.02 11 kV Indoor/Outdoor Switchgear | Per Panel | 2140.34 | 2140.34 | 1.0 | False | None | None | False | None | False | 2140.34 | 0 |
2446468 | 73730 | None | VJP117 | Erection of LT Kiosk | Per Panel | 1780.87 | 1780.87 | 1.0 | False | None | None | False | None | False | 1780.87 | 0 |
2446469 | 73730 | None | VJP118 | Erection of HT metering Cubicle on Platform. | Nos | 1899.32 | 1899.32 | 1.0 | False | None | None | False | None | False | 1899.32 | 0 |
2446470 | 73730 | None | VJP119 | Erection of 200 - 250 kVA Transformer | Nos | 2346.34 | 2346.34 | 1.0 | False | None | None | False | None | False | 2346.34 | 0 |
2446471 | 73730 | None | VJP120 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth | Cum | 99.75 | 99.75 | 532.5 | False | None | None | False | None | False | 53116.875 | 0 |
2446472 | 73730 | None | VJP121 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work1.14.1 In all kinds of soils Depth upto 3 m | Cum | 107.1 | 107.1 | 282.79 | False | None | None | False | None | False | 30286.809 | 0 |
2446473 | 73730 | None | VJP122 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work in ordinary/soft rock without blasting upto 1.5 m depth | Cum | 381.15 | 381.15 | 147.23 | False | None | None | False | None | False | 56116.7145 | 0 |
2446474 | 73730 | None | VJP123 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.(Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates) | Cum | 5947.2 | 5947.2 | 19.39 | False | None | None | False | None | False | 115316.208 | 0 |
2446475 | 73730 | None | VJP124 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.(Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates) | Cum | 6288.45 | 6288.45 | 78.53 | False | None | None | False | None | False | 493831.9785 | 0 |
2446476 | 73730 | None | VJP125 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RCC for Footing (Including 8% for Centering) | Cum | 7185.02 | 7185.02 | 44.73 | False | None | None | False | None | False | 321385.9446 | 0 |
2446477 | 73730 | None | VJP126 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RCC for Columns (Including 70% for Centering) | Cum | 11566.8 | 11566.8 | 19.56 | False | None | None | False | None | False | 226246.608 | 0 |
2446478 | 73730 | None | VJP127 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RCC for Retaining wall (Including 10% for Centering) | Cum | 7484.4 | 7484.4 | 30.6 | False | None | None | False | None | False | 229022.64 | 0 |
2446479 | 73730 | None | VJP128 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RCC for slab (Including 45% for Centering) | Cum | 9865.8 | 9865.8 | 20.29 | False | None | None | False | None | False | 200177.082 | 0 |
2446480 | 73730 | None | VJP129 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RCC for PB (Including 50% for Centering) | Cum | 10206.0 | 10206.0 | 50.72 | False | None | None | False | None | False | 517648.32 | 0 |
2446481 | 73730 | None | VJP130 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 279.3 | 279.3 | 338.79 | False | None | None | False | None | False | 94624.047 | 0 |
2446482 | 73730 | None | VJP131 | Construction of Embankment by excavating the available approved Gravel/ Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. | Cum | 497.7 | 497.7 | 500.66 | False | None | None | False | None | False | 249178.482 | 0 |
2446483 | 73730 | None | VJP132 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. | Tonne | 93929.85 | 93929.85 | 18.1 | False | None | None | False | None | False | 1700130.285 | 0 |
2446484 | 73730 | None | VJP133 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. | Kg | 188.49 | 188.49 | 150.0 | False | None | None | False | None | False | 28273.5 | 0 |
2446485 | 73730 | None | VJP134 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineerin- Charge. | Kg | 144.9 | 144.9 | 90.0 | False | None | None | False | None | False | 13041.0 | 0 |
2446486 | 73730 | None | VJP135 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 120.75 | 120.75 | 24.75 | False | None | None | False | None | False | 2988.5625 | 0 |
2446487 | 73730 | None | VJP136 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 2764.65 | 2764.65 | 24.75 | False | None | None | False | None | False | 68425.0875 | 0 |
2446488 | 73730 | None | VJP137 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diamete | m | 305.55 | 305.55 | 95.0 | False | None | None | False | None | False | 29027.25 | 0 |
2446489 | 73730 | None | VJP138 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates) | Cum | 6639.15 | 6639.15 | 117.79 | False | None | None | False | None | False | 782025.4785 | 0 |
2446490 | 73730 | None | VJP139 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings,brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in Charge. | Kg | 142.8 | 142.8 | 9240.26 | False | None | None | False | None | False | 1319509.128 | 0 |
2446491 | 73730 | None | VJP140 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings,brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in Charge. (1% lift charges) | Kg | 144.23 | 144.23 | 8664.05 | False | None | None | False | None | False | 1249615.9315 | 0 |
2446492 | 73730 | None | VJP141 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings,brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in Charge. (2% lift charges) | Kg | 145.66 | 145.66 | 37148.34 | False | None | None | False | None | False | 5411027.2044 | 0 |
2446493 | 73730 | None | VJP142 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. | Sqm | 596.4 | 596.4 | 1697.67 | False | None | None | False | None | False | 1012490.388 | 0 |
2446494 | 73730 | None | VJP143 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges plain (500 - 600mm) | m | 473.55 | 473.55 | 46.46 | False | None | None | False | None | False | 22001.133 | 0 |
2446495 | 73730 | None | VJP144 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Flashings/ Aprons ( Upto 600 mm) | m | 433.65 | 433.65 | 119.46 | False | None | None | False | None | False | 51803.829 | 0 |
2446496 | 73730 | None | VJP145 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Gutter (600 mm over all girth) | m | 1127.7 | 1127.7 | 119.46 | False | None | None | False | None | False | 134715.042 | 0 |
2446497 | 73730 | None | VJP146 | Finishing with Epoxy paint (two coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Enginer-in-charge. | Sqm | 184.8 | 184.8 | 2755.63 | False | None | None | False | None | False | 509240.424 | 0 |
2446498 | 73730 | None | VJP147 | Insulation & Refrigerator System | Each | 14713320.0 | 14713320.0 | 1.0 | False | None | None | False | None | False | 14713320.0 | 0 |
2446499 | 73730 | None | VJP148 | Heavy Duty Mezzanine Floor and Staircase with Hand Railing ( G + 2 Levels ) | Each | 8801100.0 | 8801100.0 | 1.0 | False | None | None | False | None | False | 8801100.0 | 0 |
2446500 | 73730 | None | VJP149 | Goods Lift - Wire Rope Drum Type Hoist for 2 floors. | Each | 1100000.0 | 1100000.0 | 1.0 | False | None | None | False | None | False | 1100000.0 | 0 |
2446501 | 73730 | None | VJP150 | Concealed Conduit System
Supplying heavy gauge PVC conduit pipe ........mm dia.......mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary 19/20mm die 2mm thick | Per Mtr | 69.3 | 69.3 | 120.0 | False | None | None | False | None | False | 8316.0 | 0 |
2446502 | 73730 | None | VJP151 | Concealed Conduit System
Supplying heavy gauge PVC conduit pipe ........mm dia.......mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) - a) 25 mm dia 2 mm thick | Per Mtr | 81.9 | 81.9 | 100.0 | False | None | None | False | None | False | 8190.0 | 0 |
2446503 | 73730 | None | VJP152 | Supplying heavy gauge PVC conduit pipe ........mm dia.......mm thick with suitable size bends, metal/PVC junction boxes adhesive paste etc.,by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19/20mm dia 2mm thick | Per Mtr | 71.4 | 71.4 | 116.0 | False | None | None | False | None | False | 8282.4 | 0 |
2446504 | 73730 | None | VJP153 | Supplying heavy gauge PVC conduit pipe ........mm dia.......mm thick with suitable size bends, metal/PVC junction boxes adhesive paste etc.,by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 25mm dia 2mm thick | Per Mtr | 82.95 | 82.95 | 90.0 | False | None | None | False | None | False | 7465.5 | 0 |
2446505 | 73730 | None | VJP154 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments)without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet short Point | Point | 282.45 | 282.45 | 12.0 | False | None | None | False | None | False | 3389.4 | 0 |
2446506 | 73730 | None | VJP155 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. 3 Mtr up to 6Mtr from tapping point to out let via switch | Point | 397.95 | 397.95 | 6.0 | False | None | None | False | None | False | 2387.7 | 0 |
2446507 | 73730 | None | VJP156 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. t. Group - A. Long point a above 6 Mtr up to 10Mtr from tapping point to out let via switch | Point | 582.75 | 582.75 | 12.0 | False | None | None | False | None | False | 6993.0 | 0 |
2446508 | 73730 | None | VJP157 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper conductor resistance single core wire in open or consealed system of wiring with specified IS- 694:1990 & confirming to GTP of Group - A.1.0sqmm. | Per Mtr | 19.95 | 19.95 | 200.0 | False | None | None | False | None | False | 3990.0 | 0 |
2446509 | 73730 | None | VJP158 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper conductor resistance single core wire in open or consealed system of wiring with specified IS- 694:1990 & confirming to GTP of Group - A.2.5sqmm. | Per Mtr | 44.1 | 44.1 | 600.0 | False | None | None | False | None | False | 26460.0 | 0 |
2446510 | 73730 | None | VJP159 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper conductor resistance single core wire in open or consealed system of wiring with specified IS- 694:1990 & confirming to GTP of Group - A.4.0sqmm. | Per Mtr | 66.15 | 66.15 | 200.0 | False | None | None | False | None | False | 13230.0 | 0 |
2446511 | 73730 | None | VJP160 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall..1-3Way | Each | 166.95 | 166.95 | 6.0 | False | None | None | False | None | False | 1001.7 | 0 |
2446512 | 73730 | None | VJP161 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall..4-5Way | Each | 185.85 | 185.85 | 2.0 | False | None | None | False | None | False | 371.7 | 0 |
2446513 | 73730 | None | VJP162 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall..6Way | Each | 231.0 | 231.0 | 2.0 | False | None | None | False | None | False | 462.0 | 0 |
2446514 | 73730 | None | VJP163 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall..8Way | Each | 274.05 | 274.05 | 4.0 | False | None | None | False | None | False | 1096.2 | 0 |
2446515 | 73730 | None | VJP164 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall..10-12Way | Each | 334.95 | 334.95 | 1.0 | False | None | None | False | None | False | 334.95 | 0 |
2446516 | 73730 | None | VJP165 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box...1 to 3 Module | Each | 169.05 | 169.05 | 6.0 | False | None | None | False | None | False | 1014.3 | 0 |
2446517 | 73730 | None | VJP166 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box..4 Module | Each | 183.75 | 183.75 | 2.0 | False | None | None | False | None | False | 367.5 | 0 |
2446518 | 73730 | None | VJP167 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box..6 Module | Each | 245.7 | 245.7 | 2.0 | False | None | None | False | None | False | 491.4 | 0 |
2446519 | 73730 | None | VJP168 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box..8 Module | Each | 298.2 | 298.2 | 4.0 | False | None | None | False | None | False | 1192.8 | 0 |
2446520 | 73730 | None | VJP169 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box..12 Module | Each | 361.2 | 361.2 | 1.0 | False | None | None | False | None | False | 361.2 | 0 |
2446521 | 73730 | None | VJP170 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6Amps one way Switch | Each | 107.1 | 107.1 | 60.0 | False | None | None | False | None | False | 6426.0 | 0 |
2446522 | 73730 | None | VJP171 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6Amps Two way Switch | Each | 174.3 | 174.3 | 3.0 | False | None | None | False | None | False | 522.9 | 0 |
2446523 | 73730 | None | VJP172 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6Amps 3way socket | Each | 179.55 | 179.55 | 10.0 | False | None | None | False | None | False | 1795.5 | 0 |
2446524 | 73730 | None | VJP173 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 16Amps one way switch | Each | 189.0 | 189.0 | 4.0 | False | None | None | False | None | False | 756.0 | 0 |
2446525 | 73730 | None | VJP174 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 32Amps DP switch | Each | 342.3 | 342.3 | 6.0 | False | None | None | False | None | False | 2053.8 | 0 |
2446526 | 73730 | None | VJP175 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6/16Amps universal socket | Each | 247.8 | 247.8 | 6.0 | False | None | None | False | None | False | 1486.8 | 0 |
2446527 | 73730 | None | VJP176 | Supplying & Fixing of 70-150 Watts lamp holder 2 Pin | No | 66.15 | 66.15 | 4.0 | False | None | None | False | None | False | 264.6 | 0 |
2446528 | 73730 | None | VJP177 | Supplying & fixing retrofit type -PL- LED Lamp .......W LED linear source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit rotection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.8-9 Watts | Each | 737.1 | 737.1 | 3.0 | False | None | None | False | None | False | 2211.3 | 0 |
2446529 | 73730 | None | VJP178 | Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fighting 1 x4'- 20/22 w | Each | 724.5 | 724.5 | 4.0 | False | None | None | False | None | False | 2898.0 | 0 |
2446530 | 73730 | None | VJP179 | Supplying of recess mounting non integral type ........ LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per W, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.LED modular down light 1'x4' 34-36W | Each | 6171.76 | 6171.76 | 21.0 | False | None | None | False | None | False | 129606.96 | 0 |
2446531 | 73730 | None | VJP180 | Supplying of on load change over switches 4 poles,AC-23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM Enclosure Sheet Metal Execution) 630 Amps | Each | 39947.25 | 39947.25 | 1.0 | False | None | None | False | None | False | 39947.25 | 0 |
2446532 | 73730 | None | VJP181 | Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 40 Amps | Each | 4294.5 | 4294.5 | 1.0 | False | None | None | False | None | False | 4294.5 | 0 |
2446533 | 73730 | None | VJP182 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. ( Icu = Ics) FOUR POLE 100Amps 25kA. | Each | 8911.35 | 8911.35 | 1.0 | False | None | None | False | None | False | 8911.35 | 0 |
2446534 | 73730 | None | VJP183 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. ( Icu = Ics) FOUR POLE500-630Amps 50kA. | Each | 43993.95 | 43993.95 | 3.0 | False | None | None | False | None | False | 131981.85 | 0 |
2446535 | 73730 | None | VJP184 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32Amps SP | Each | 435.75 | 435.75 | 10.0 | False | None | None | False | None | False | 4357.5 | 0 |
2446536 | 73730 | None | VJP185 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 Amps DP | Each | 775.95 | 775.95 | 2.0 | False | None | None | False | None | False | 1551.9 | 0 |
2446537 | 73730 | None | VJP186 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.40 Amps TPN | Each | 3242.4 | 3242.4 | 2.0 | False | None | None | False | None | False | 6484.8 | 0 |
2446538 | 73730 | None | VJP187 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure.12Way SP &N | Each | 2445.45 | 2445.45 | 1.0 | False | None | None | False | None | False | 2445.45 | 0 |
2446539 | 73730 | None | VJP188 | Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 16SWG | Sq CM | 0.45 | 0.45 | 200000.0 | False | None | None | False | None | False | 90000.0 | 0 |
2446540 | 73730 | None | VJP189 | Supplying, fixing and wiring Automatic Power Factor controller circuit unit fully, static units controlled by 14 stage microprocessor operation, relays LED display, self programming function for power stages and operating logic checking facility for healthy and efficient of each individual capacitor bank, measurement of network harmonics with indication when limit values are exceeded, Comprehensive displays with large, three phase LED display, Long term memory for settings, protection for over voltage, power factor correction fault and no voltage, to connect / disconnect banks, with automatic recognition or with standard programs. | Each | 22722.0 | 22722.0 | 1.0 | False | None | None | False | None | False | 22722.0 | 0 |
2446541 | 73730 | None | VJP190 | Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 600Amps 4x75x10mm Aluminium Strips | Mtr | 5906.25 | 5906.25 | 5.0 | False | None | None | False | None | False | 29531.25 | 0 |
2446542 | 73730 | None | VJP191 | Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH, KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy. | Each | 9780.75 | 9780.75 | 1.0 | False | None | None | False | None | False | 9780.75 | 0 |
2446543 | 73730 | None | VJP192 | Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound. | Each | 590.1 | 590.1 | 3.0 | False | None | None | False | None | False | 1770.3 | 0 |
2446544 | 73730 | None | VJP193 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440v A.C. 50 Hz 12/24v D.C. | Each | 540.75 | 540.75 | 3.0 | False | None | None | False | None | False | 1622.25 | 0 |
2446545 | 73730 | None | VJP194 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 50x50x6mm | Mtr | 414.75 | 414.75 | 16.0 | False | None | None | False | None | False | 6636.0 | 0 |
2446546 | 73730 | None | VJP195 | Supplying and fixing Microprocessor Based Astronomical timer Switch with using necessary bolts, nuts and washers. | Each | 5085.15 | 5085.15 | 1.0 | False | None | None | False | None | False | 5085.15 | 0 |
2446547 | 73730 | None | VJP196 | Earth work excavation for pipeline trenches in all kinds of soils by mechanical
means as per drawing and technical specifications, including setting out,
construction of shoring, strutting, barricading, caution lights, bracing, using
sight rails & bonding rods at every 100 mm wherever necessary as directed,
removal of stumps and other deleterious matter, dressing of sides and levelling
the bottom of trench to the extent required , utilising the available excavated
earth locally for the work etc., and all other appurtenances complete in the
following strata | Cum | 275.1 | 275.1 | 40.0 | False | None | None | False | None | False | 11004.0 | 0 |
2446548 | 73730 | None | VJP197 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 240 Sqmm, 3.5 Core, (30 GI Strips - 4 x 0.8 mm)(From L.T.Distribution Box To Main Panel) | Km | 905799.3 | 905799.3 | 0.16 | False | None | None | False | None | False | 144927.888 | 0 |
2446549 | 73730 | None | VJP198 | Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe / stoneware pipe / on wall / on pole as required. 185sqmm to 240Sqmm | Km | 33891.9 | 33891.9 | 0.16 | False | None | None | False | None | False | 5422.704 | 0 |
2446550 | 73730 | None | VJP199 | Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour complete as per specifications | Cum | 168.0 | 168.0 | 40.0 | False | None | None | False | None | False | 6720.0 | 0 |
2446551 | 73730 | None | VJP200 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia
2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification
7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia | No | 3685.5 | 3685.5 | 4.0 | False | None | None | False | None | False | 14742.0 | 0 |
2446552 | 73730 | None | VJP201 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. 13.7.1 On wall / ceiling / Rafter / Girders | Each | 128.1 | 128.1 | 28.0 | False | None | None | False | None | False | 3586.8 | 0 |
2446553 | 73730 | None | VJP202 | Supply and installation of 2 Kg C02 Gas Type Fire Extinugisher Squeeze grip type, used Unused Mechanism, Squeeze Grip, Gross Weight 9.1 Kg. empty Weight 7.1 Kg. Can Height 595MM Diameter 108MM, Discharge Time less than 8 Sees, Controllable discharge mechanism, Applicable on Class 8&C Fire, 8 Rating 88, Can Construction : Hot spinning/Forging, Valve Construction : Forging & Machining, Internal Coating of Can : Not Applicable, External coating of Can : Spray Painting, Sheet metal thickness: 4.0MM lSI Approved, 1 Year Warranty.with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost cost of supporting materials like MS stand & accessaries if it is fixing n floor / MS brackets & accessories if it is fixing on wall,, labour, usage charges of machinery complete as per specifications. complete | Each | 5775.0 | 5775.0 | 10.0 | False | None | None | False | None | False | 57750.0 | 0 |
2446554 | 73730 | None | VJP203 | Caution/Danger Board | Each | 157.5 | 157.5 | 10.0 | False | None | None | False | None | False | 1575.0 | 0 |
2446555 | 73730 | None | VJP204 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency1301m/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source.LED Streetlight 70W | Each | 6171.76 | 6171.76 | 6.0 | False | None | None | False | None | False | 37030.56 | 0 |
2446556 | 73730 | None | VJP205 | Supplying and Fixing of........mm dia class A GI pipe bracket upto 2 ms long bent at suitable angle and fixing to this bracket street light fitting of all capacities to GI or GI or rail or RCC pole / wall using suitable clamps, bolts, and nuts and wiring using suitable capacity wires.Using 32mm dia G.I.Pipe | Each | 1076.35 | 1076.35 | 6.0 | False | None | None | False | None | False | 6458.1 | 0 |
2446557 | 73730 | None | VJP206 | Providing 2 Pole Structrue at the Tapping Point Using RCC Pole using 9 mtr RCC Pole Complete set | Each | 69127.8 | 69127.8 | 2.0 | False | None | None | False | None | False | 138255.6 | 0 |
2446558 | 73730 | None | VJP207 | RCC Pole - 9 Mtr Long, 145 Kg WL (Dwg No. BESCOM/GM/QS&S/02 Dtd 24.11.2018) | Nos | 7429.8 | 7429.8 | 2.0 | False | None | None | False | None | False | 14859.6 | 0 |
2446559 | 73730 | None | VJP208 | PSCC Pole - 9 Mtr Long, 200 Kg WL (Dwg No. BESCOM/GM/QS&S/50 Dtd 24.11.2018) as per REC Standards | Nos | 4408.95 | 4408.95 | 6.0 | False | None | None | False | None | False | 26453.7 | 0 |
2446560 | 73730 | None | VJP209 | 11 kV, Horizontal Cross Arm - Galvanised Iron (GI) | Nos | 511.35 | 511.35 | 8.0 | False | None | None | False | None | False | 4090.8 | 0 |
2446561 | 73730 | None | VJP210 | 11 kV, Special 3 Pin Cross Arm - GI | Nos | 1208.55 | 1208.55 | 24.0 | False | None | None | False | None | False | 29005.2 | 0 |
2446562 | 73730 | None | VJP211 | Insulator as per IS-1445 for Ceremic, IS-7935 for GI Pin, IEC-61109 for Polymeric DISC Insulator 45 kN Porcelain | Nos | 535.5 | 535.5 | 12.0 | False | None | None | False | None | False | 6426.0 | 0 |
2446563 | 73730 | None | VJP212 | ACSR Conductor as per IS-398 (Part - 2/1996) Rabbit ACSR | Km | 48545.7 | 48545.7 | 1.2 | False | None | None | False | None | False | 58254.84 | 0 |
2446564 | 73730 | None | VJP213 | Guy Wire & GI Wire as per IS-2141 8 SWG GI Wire 281008 | MT | 78792.0 | 78792.0 | 0.05 | False | None | None | False | None | False | 3939.6 | 0 |
2446565 | 73730 | None | VJP214 | Erection of RCC/PSCC Pole of 9 to 10 Mtr long in a pit of 1.8 Mtr depth | Each | 1168.65 | 1168.65 | 8.0 | False | None | None | False | None | False | 9349.2 | 0 |
2446566 | 73730 | None | VJP215 | Distribution Transformer - 3 Phase, 11kV/433V - Stacked CRGO Core with Oil as per IS-1180 (Part-1): 2014 500 kVA, Aluminium Wdg, Star 2 (5 Star) | Nos | 959467.95 | 959467.95 | 1.0 | False | None | None | False | None | False | 959467.95 | 0 |
2446567 | 73730 | None | VJP216 | 11 kV HT Metering cubicle of different CT Ratio, Both side cable entry type with 3 CT & 3 PT, With Transparent Cover TTB, with 30x8 mm Copper Busbar, Modem & 2 No of Meters for 3 Phase 4 Wire Metering without Load Break Switch (HT Metering Box Fabricated out of 3 mm MS Sheet duly epoxy powder coated) as per revised Specification
(Dwg No. BESCOM/GM/QS&S/-- Dtd 24.11.2018) | Each | 255645.6 | 255645.6 | 1.0 | False | None | None | False | None | False | 255645.6 | 0 |
2446568 | 73730 | None | VJP217 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. GI strip 25x6mm | Mtr | 86.1 | 86.1 | 60.0 | False | None | None | False | None | False | 5166.0 | 0 |
2446569 | 73730 | None | VJP218 | Construction of platform with size stone, cement concert for erection of 500 kVA Transformer/Metering cubicle/Heavy Equipment. Construction of platform (1.5x1.5x1.2) Mtr in size stone, for erection of transformers/Heavy equipment including all materials, labour. Excavation of (1.5x1.5x1) Mtr pit for foundation providing and laying cement concrete 1:4:8 for foundation laid in 10 cm thick layers, well compacted curing etc., complete providing and construction of stone masonary 0.9 Mtr below ground level and 1.2 Mtr above ground level neatly hammer dressed in cement morter 1:6. Providing and Laying cement concrete slab 1.5x1.5x0.10 Mtr with cement concrete of 1:2:4 mix forming & cutting complete, providing pointing to stone masonary in cement morter 1:3 after racking joint & nisely lining curing etc., plastering the concrete surfaces in cement morter 1:4 including smooth randering curing etc., curing at every stages completely. | Nos | 31879.05 | 31879.05 | 4.0 | False | None | None | False | None | False | 127516.2 | 0 |
2446570 | 73730 | None | VJP219 | HT Cable GROUP A: Supplying and laying of high tension 11KV cable, Dry Curing & Dry Cooling with true triple extrusion, simultaneously through a single common head, 3 core under ground XLPE (E) cable having stranded compact circular aluminium conductor, screened insulated, insulation screened with extruded semiconducting compound in combination with copper tape, core laid up extruded inner sheathed of GI flat strip armoured and overall PVC sheathed with specified IS 7098/11/85 with latest amendments & confirming to the GTP of GROUP-A240 Sqmm, (55 GI Wires - 3.15 mm Dia) | Km | 1738850.4 | 1738850.4 | 0.1 | False | None | None | False | None | False | 173885.04 | 0 |
2446571 | 73730 | None | VJP220 | Earth work excavation for pipeline trenches in all kinds of soils by mechanical
means as per drawing and technical specifications, including setting out,
construction of shoring, strutting, barricading, caution lights, bracing, using
sight rails & bonding rods at every 100 mm wherever necessary as directed,
removal of stumps and other deleterious matter, dressing of sides and levelling
the bottom of trench to the extent required , utilising the available excavated
earth locally for the work etc., and all other appurtenances complete in the
following strataIn soil (ordinary) | Cum | 275.1 | 275.1 | 40.0 | False | None | None | False | None | False | 11004.0 | 0 |
2446572 | 73730 | None | VJP221 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staffHT Cable3x185 to 240 Sqmm | Km | 67360.65 | 67360.65 | 0.1 | False | None | None | False | None | False | 6736.065 | 0 |
2446573 | 73730 | None | VJP222 | Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour complete as per specifications | Cum | 168.0 | 168.0 | 40.0 | False | None | None | False | None | False | 6720.0 | 0 |
2446574 | 73730 | None | VJP223 | Spreading and forming with sand all round the cable to a depth of 75 mm and width of 500 mm. (Does not include cost of sand). | Km | 15550.5 | 15550.5 | 0.6 | False | None | None | False | None | False | 9330.3 | 0 |
2446575 | 73730 | None | VJP224 | Supplying at site Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. etc. complete. .00 1 | Kg | 118.65 | 118.65 | 60.0 | False | None | None | False | None | False | 7119.0 | 0 |
2446576 | 73730 | None | VJP225 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size 25x25 mm made of G.I. wire of dia 3 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. | Sqm | 937.65 | 937.65 | 80.0 | False | None | None | False | None | False | 75012.0 | 0 |
2446577 | 73730 | None | VJP226 | Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40 mm dia 2.9 mm thick 2.5m long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400 mm with a cast iron cover. The earth electrode shall have staggered holes of 12 mm dia and the electrode should be covered 150 mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts. | Nos | 4468.8 | 4468.8 | 9.0 | False | None | None | False | None | False | 40219.2 | 0 |
2446578 | 73730 | None | VJP227 | Solar Photovoltaic Power Plant Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:- a) Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. c) Data Monitoring System complete with accessories. d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. e) Lightning and surge voltage protection. f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required. | Nos | 64113.0 | 64113.0 | 5.0 | False | None | None | False | None | False | 320565.0 | 0 |
2446579 | 73730 | None | VJP228 | Load Break Switch with Panel | Unit | 76900.95 | 76900.95 | 1.0 | False | None | None | False | None | False | 76900.95 | 0 |
2446580 | 73730 | None | VJP229 | Supplying of four bucket stand alongwith buckets. Complete | Each | 1942.5 | 1942.5 | 6.0 | False | None | None | False | None | False | 11655.0 | 0 |
2446581 | 73730 | None | VJP230 | Supplying of Hand gloves. complete | Each | 1023.75 | 1023.75 | 6.0 | False | None | None | False | None | False | 6142.5 | 0 |
2446582 | 73730 | None | VJP231 | Supplying of first aid box. complete | Each | 630.0 | 630.0 | 3.0 | False | None | None | False | None | False | 1890.0 | 0 |
2446583 | 73730 | None | VJP232 | Supplying of SAFETY MASK. complete | Each | 157.5 | 157.5 | 3.0 | False | None | None | False | None | False | 472.5 | 0 |
2446584 | 73730 | None | VJP233 | Supplying of FIRST AID CHART with lamination. Complete | Each | 420.0 | 420.0 | 3.0 | False | None | None | False | None | False | 1260.0 | 0 |
2446585 | 73730 | None | VJP234 | Supplying and installation of RUBBER MAT 1mtr x 1mtr -1Omm thick.
complete including cost of materials, labour, usage charges of machinery complete as per specifications. | Each | 1995.0 | 1995.0 | 5.0 | False | None | None | False | None | False | 9975.0 | 0 |
2446586 | 73730 | None | VJP235 | Erection, alignment and fixing to the foundation, indoor/outdoor 11KV switchgear panel/unit including movement from the point of unloading to the point of erction. 331 41.02 11 kV Indoor/Outdoor Switchgear | Per Panel | 2181.9 | 2181.9 | 1.0 | False | None | None | False | None | False | 2181.9 | 0 |
2446587 | 73730 | None | VJP236 | Erection of LT Kiosk | Per Panel | 1815.45 | 1815.45 | 1.0 | False | None | None | False | None | False | 1815.45 | 0 |
2446588 | 73730 | None | VJP237 | Erection of HT metering Cubicle on Platform. | Nos | 1936.2 | 1936.2 | 1.0 | False | None | None | False | None | False | 1936.2 | 0 |
2446589 | 73730 | None | VJP238 | Erection of 300 - 500 kVA Transformer | Nos | 3239.25 | 3239.25 | 1.0 | False | None | None | False | None | False | 3239.25 | 0 |