2438841 | 73390 | None | code01 | Earth work excavation for Foundation by mechanical means for all kind of soil & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Cum | 107.1 | 107.1 | 327.87 | False | 0.0 | 0.0 | False | None | False | 35114.877 | 0 |
2438842 | 73390 | None | code02 | Providing and laying in position plain cement concrete 1:4:8( M5) Using 40 mm nominal size for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Cum | 5947.2 | 5947.2 | 248.43 | False | None | None | False | None | False | 1477462.896 | 0 |
2438843 | 73390 | None | code03 | Providing and laying in position plain cement concrete Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Cum | 6527.85 | 6527.85 | 248.28 | False | None | None | False | None | False | 1620734.598 | 0 |
2438844 | 73390 | None | code04 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Cum | 6708.45 | 6708.45 | 185.12 | False | None | None | False | None | False | 1241868.264 | 0 |
2438845 | 73390 | None | code05 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. this rate is inclusive of form work Footings | Cum | 7185.02 | 7185.02 | 45.936 | False | None | None | False | None | False | 330051.07872 | 0 |
2438846 | 73390 | None | code06 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. this rate is inclusive of form work Plinth Beam | Cum | 10206.0 | 10206.0 | 20.4861 | False | None | None | False | None | False | 209081.1366 | 0 |
2438847 | 73390 | None | code07 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. this rate is inclusive of form work Pedestal | Cum | 11566.8 | 11566.8 | 20.45 | False | None | None | False | None | False | 236541.06 | 0 |
2438848 | 73390 | None | code08 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. this rate is inclusive of form work Lintel & Tie Beam | Cum | 11496.24 | 11496.24 | 1.029 | False | None | None | False | None | False | 11829.63096 | 0 |
2438849 | 73390 | None | code09 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. this rate is inclusive of form work for Chejjas | Cum | 10418.46 | 10418.46 | 5.9265 | False | None | None | False | None | False | 61745.00319 | 0 |
2438850 | 73390 | None | code10 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Sqm | 1292.55 | 1292.55 | 46.68 | False | None | None | False | None | False | 60336.234 | 0 |
2438851 | 73390 | None | code11 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | MT | 93929.85 | 93929.85 | 13.52 | False | None | None | False | None | False | 1269931.572 | 0 |
2438852 | 73390 | None | code12 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Cum | 6639.15 | 6639.15 | 317.14 | False | None | None | False | None | False | 2105540.031 | 0 |
2438853 | 73390 | None | code13 | Providing 12 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Sqm | 267.75 | 267.75 | 87.09 | False | None | None | False | None | False | 23318.3475 | 0 |
2438854 | 73390 | None | code14 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Sqm | 366.45 | 366.45 | 223.5 | False | None | None | False | None | False | 81901.575 | 0 |
2438855 | 73390 | None | code15 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Kgs | 192.15 | 192.15 | 72.0 | False | None | None | False | None | False | 13834.8 | 0 |
2438856 | 73390 | None | code16 | Providing & fixing of 2 track x 2 panel sliding windows made out of multi chambered UPVC(Matching to RAL 9016) sections and with minimum TiO2(Titanium Dioxide) at 6 PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets grey color having isolated drainage and reinforced with Galvanized Iron profile through out the window frame. The outer frame having an overall size of 44mm width x 40mmheight with reinforcement of 1mm thickness and Sash with overall size of 27mm X 53mm with UPVC honeycomb structure inside in lieu of GI reinforcement. Coextruded Glazing bead for fixing of glass shall be of size 9.5 mm x 21.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with Crescent Locks. Wall thickness of frame & sash shall be of 2 mm.Maximum possible size 1219mm x 1219mm. (The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made) with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Sqm | 5274.15 | 5274.15 | 2.88 | False | None | None | False | None | False | 15189.552 | 0 |
2438857 | 73390 | None | code17 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Sqm | 2764.65 | 2764.65 | 9.0 | False | None | None | False | None | False | 24881.85 | 0 |
2438858 | 73390 | None | code18 | Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance Plus/ minus 1mm), with wall thickness 2.0 mm (Plus / minus 0.2 mm) corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (Plus / minus 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturers specification and direction of Engineer- in-charge 42x50 mm PVC Extruded section with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Mtr | 250.95 | 250.95 | 12.0 | False | None | None | False | None | False | 3011.4 | 0 |
2438859 | 73390 | None | code19 | Providing& fixing of Openable door made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 900mm x 2400mm. (The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made) with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Sqm | 6557.25 | 6557.25 | 3.78 | False | None | None | False | None | False | 24786.405 | 0 |
2438860 | 73390 | None | code20 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Sqm | 3660.0 | 3660.0 | 2.57 | False | None | None | False | None | False | 9406.2 | 0 |
2438861 | 73390 | None | code21 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and in- cluding water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Sqm | 143.85 | 143.85 | 87.09 | False | None | None | False | None | False | 12527.8965 | 0 |
2438862 | 73390 | None | code22 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Sqm | 93.45 | 93.45 | 223.5 | False | None | None | False | None | False | 20886.075 | 0 |
2438863 | 73390 | None | code23 | Finishing with Epoxy paint (two coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Enginer-in-charge. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Sqm | 184.8 | 184.8 | 1000.0 | False | None | None | False | None | False | 184800.0 | 0 |
2438864 | 73390 | None | code24 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Sqm | 120.75 | 120.75 | 23.759 | False | None | None | False | None | False | 2868.89925 | 0 |
2438865 | 73390 | None | code25 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Mtr | 305.55 | 305.55 | 110.0 | False | None | None | False | None | False | 33610.5 | 0 |
2438866 | 73390 | None | code26 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Cum | 279.3 | 279.3 | 1031.18 | False | None | None | False | None | False | 288008.574 | 0 |
2438867 | 73390 | None | code27 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer- in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Sqm | 596.4 | 596.4 | 3361.2 | False | None | None | False | None | False | 2004619.68 | 0 |
2438868 | 73390 | None | code28 | ProviProviding and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges plain (500 - 600mm) with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Rmtr | 473.55 | 473.55 | 65.0 | False | None | None | False | None | False | 30780.75 | 0 |
2438869 | 73390 | None | code29 | ProviProviding and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete Gutter (600 mm over all girth) with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Rmtr | 1127.7 | 1127.7 | 130.0 | False | None | None | False | None | False | 146601.0 | 0 |
2438870 | 73390 | None | code30 | ProviProviding and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete Flashings/ Aprons.( Upto 600 mm) with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Rmtr | 433.65 | 433.65 | 192.0 | False | None | None | False | None | False | 83260.8 | 0 |
2438871 | 73390 | None | code31 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Kg | 142.8 | 142.8 | 67950.34 | False | None | None | False | None | False | 9703308.552 | 0 |
2438872 | 73390 | None | code32 | Open Conduit System Supplying heavy gauge PVC conduit pipe …….dia .......mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.25mm dia 2mm thick. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Mtr | 85.05 | 85.05 | 800.0 | False | None | None | False | None | False | 68040.0 | 0 |
2438873 | 73390 | None | code33 | Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete.upto 50mm conduit in brick wall with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Mtr | 30.45 | 30.45 | 20.0 | False | None | None | False | None | False | 609.0 | 0 |
2438874 | 73390 | None | code34 | Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete.upto 50mm conduit CC floor. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Mtr | 72.45 | 72.45 | 20.0 | False | None | None | False | None | False | 1449.0 | 0 |
2438875 | 73390 | None | code35 | Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, screws at an interval of 300mm …. etc. as required.25mm with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Mtr | 36.75 | 36.75 | 20.0 | False | None | None | False | None | False | 735.0 | 0 |
2438876 | 73390 | None | code36 | Supplying PVC/GI flexible conduit pipe…mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of thepi pe terminated completely 25mm. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Mtr | 23.1 | 23.1 | 350.0 | False | None | None | False | None | False | 8085.0 | 0 |
2438877 | 73390 | None | code37 | Supplying PVC/GI flexible conduit pipe…mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of thepi pe terminated completely 32mm. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Mtr | 30.45 | 30.45 | 20.0 | False | None | None | False | None | False | 609.0 | 0 |
2438878 | 73390 | None | code38 | Supplying And Fixing Metal Fan Box with Round Hook. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 122.85 | 122.85 | 4.0 | False | None | None | False | None | False | 491.4 | 0 |
2438879 | 73390 | None | code39 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Short point upto 3Mtr from tapping point to out let via switch with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 282.45 | 282.45 | 2.0 | False | None | None | False | None | False | 564.9 | 0 |
2438880 | 73390 | None | code40 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Medium point above 3M. upto 6M from tapping point to out let via switch with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 397.95 | 397.95 | 2.0 | False | None | None | False | None | False | 795.9 | 0 |
2438881 | 73390 | None | code41 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Long point above 6Mtr. upto 10M from tapping point to out let via switch with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 582.75 | 582.75 | 9.0 | False | None | None | False | None | False | 5244.75 | 0 |
2438882 | 73390 | None | code42 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Two outlet in a row, above 3Mtr upto 6Mtr from tapping point to out let via switches with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 710.85 | 710.85 | 4.0 | False | None | None | False | None | False | 2843.4 | 0 |
2438883 | 73390 | None | code43 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Three outlet in a row, above 6Mtr upto 10Mtr from tapping point to out let via switches with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 1038.45 | 1038.45 | 9.0 | False | None | None | False | None | False | 9346.05 | 0 |
2438884 | 73390 | None | code44 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.1 sqmm with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Mtr | 19.95 | 19.95 | 150.0 | False | None | None | False | None | False | 2992.5 | 0 |
2438885 | 73390 | None | code45 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.1.5 sqmm with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Mtr | 27.3 | 27.3 | 500.0 | False | None | None | False | None | False | 13650.0 | 0 |
2438886 | 73390 | None | code46 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.2.5 sqmm with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Mtr | 44.1 | 44.1 | 460.0 | False | None | None | False | None | False | 20286.0 | 0 |
2438887 | 73390 | None | code47 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.4 sqmm with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Mtr | 66.15 | 66.15 | 135.0 | False | None | None | False | None | False | 8930.25 | 0 |
2438888 | 73390 | None | code48 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.6 sqmm with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Mtr | 96.6 | 96.6 | 45.0 | False | None | None | False | None | False | 4347.0 | 0 |
2438889 | 73390 | None | code49 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS- 694:2010 3C x 2.5 mm2 with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Mtr | 118.65 | 118.65 | 275.0 | False | None | None | False | None | False | 32628.75 | 0 |
2438890 | 73390 | None | code50 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.4-5 Way with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 143.85 | 143.85 | 2.0 | False | None | None | False | None | False | 287.7 | 0 |
2438891 | 73390 | None | code51 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.6 Way with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 181.65 | 181.65 | 2.0 | False | None | None | False | None | False | 363.3 | 0 |
2438892 | 73390 | None | code52 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.8 Way with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 229.95 | 229.95 | 4.0 | False | None | None | False | None | False | 919.8 | 0 |
2438893 | 73390 | None | code53 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.16Way with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 308.7 | 308.7 | 2.0 | False | None | None | False | None | False | 617.4 | 0 |
2438894 | 73390 | None | code54 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.4 Module with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 183.75 | 183.75 | 2.0 | False | None | None | False | None | False | 367.5 | 0 |
2438895 | 73390 | None | code55 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.6 Module with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 245.7 | 245.7 | 2.0 | False | None | None | False | None | False | 491.4 | 0 |
2438896 | 73390 | None | code56 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.8 Module with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 298.2 | 298.2 | 4.0 | False | None | None | False | None | False | 1192.8 | 0 |
2438897 | 73390 | None | code57 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.16-18 Module with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 416.85 | 416.85 | 2.0 | False | None | None | False | None | False | 833.7 | 0 |
2438898 | 73390 | None | code58 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6Amps one way. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 107.1 | 107.1 | 36.0 | False | None | None | False | None | False | 3855.6 | 0 |
2438899 | 73390 | None | code59 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6Amps two way. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 174.3 | 174.3 | 4.0 | False | None | None | False | None | False | 697.2 | 0 |
2438900 | 73390 | None | code60 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6Amps 3way socket. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 179.55 | 179.55 | 10.0 | False | None | None | False | None | False | 1795.5 | 0 |
2438901 | 73390 | None | code61 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.Stepped Fan Regulator. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 374.85 | 374.85 | 4.0 | False | None | None | False | None | False | 1499.4 | 0 |
2438902 | 73390 | None | code62 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.16Amps one way switch with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 189.0 | 189.0 | 2.0 | False | None | None | False | None | False | 378.0 | 0 |
2438903 | 73390 | None | code63 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6/16Amps universal socket with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 247.8 | 247.8 | 2.0 | False | None | None | False | None | False | 495.6 | 0 |
2438904 | 73390 | None | code64 | Supplying and fixing/replacing of 6/16/32Amps electrical accessories on existing switch board.6A Batten Holder. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 77.7 | 77.7 | 6.0 | False | None | None | False | None | False | 466.2 | 0 |
2438905 | 73390 | None | code65 | Supplying of on load change over switches 4poles, AC-23 A Duty,415V,50Hz,AC Supply.With all accessories.(SM Enclosure Sheet Metal Execution) 800 A with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 61075.35 | 61075.35 | 1.0 | False | None | None | False | None | False | 61075.35 | 0 |
2438906 | 73390 | None | code66 | Supplying and fixing Moulded Case Circuit Breaker(MCCB) over theexisting wood/panel board using necessary screws,bolts,nuts,necessary phase separators,handle and wiring complete.Protection of Over load and Short circuit with adjustable thermal magnetic release,Microprocessor release shall have Earth Fault as per IS/IEC60947 2.(Icu=100%lcs).In 4P MCCB,all Poles should have protection for Short Cicrcuit / Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non Priority loads must be available in the MCCB.MCCB shall be provided with double insulation(insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open)Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.700-800 A 50 kA with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 52395.0 | 52395.0 | 2.0 | False | None | None | False | None | False | 104790.0 | 0 |
2438907 | 73390 | None | code67 | Supplying and fixing Moulded Case Circuit Breaker(MCCB) over theexisting wood/panel board using necessary screws,bolts,nuts,necessary phase separators,handle and wiring complete.Protection of Over load and Short circuit with adjustable thermal magnetic release,Microprocessor release shall have Earth Fault as per IS/IEC60947 2.(Icu=100%lcs).In 4P MCCB,all Poles should have protection for Short Cicrcuit / Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non Priority loads must be available in the MCCB.MCCB shall be provided with double insulation(insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open)Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.500-630 A 50 kA with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 43993.95 | 43993.95 | 1.0 | False | None | None | False | None | False | 43993.95 | 0 |
2438908 | 73390 | None | code68 | Supplying and fixing Moulded Case Circuit Breaker(MCCB) over theexisting wood/panel board using necessary screws,bolts,nuts,necessary phase separators,handle and wiring complete.Protection of Over load and Short circuit with adjustable thermal magnetic release,Microprocessor release shall have Earth Fault as per IS/IEC60947 2.(Icu=100%lcs).In 4P MCCB,all Poles should have protection for Short Cicrcuit / Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non Priority loads must be available in the MCCB.MCCB shall be provided with double insulation(insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open)Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.250 A 25 kA with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 22460.55 | 22460.55 | 1.0 | False | None | None | False | None | False | 22460.55 | 0 |
2438909 | 73390 | None | code69 | Supplying and fixing Moulded Case Circuit Breaker(MCCB) over theexisting wood/panel board using necessary screws,bolts,nuts,necessary phase separators,handle and wiring complete.Protection of Over load and Short circuit with adjustable thermal magnetic release,Microprocessor release shall have Earth Fault as per IS/IEC60947 2.(Icu=100%lcs).In 4P MCCB,all Poles should have protection for Short Cicrcuit / Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non Priority loads must be available in the MCCB.MCCB shall be provided with double insulation(insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open)Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.200 A 25 kA with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 18166.05 | 18166.05 | 1.0 | False | None | None | False | None | False | 18166.05 | 0 |
2438910 | 73390 | None | code70 | Supplying and fixing Moulded Case Circuit Breaker(MCCB) over theexisting wood/panel board using necessary screws,bolts,nuts,necessary phase separators,handle and wiring complete.Protection of Over load and Short circuit with adjustable thermal magnetic release,Microprocessor release shall have Earth Fault as per IS/IEC60947 2.(Icu=100%lcs).In 4P MCCB,all Poles should have protection for Short Cicrcuit / Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non Priority loads must be available in the MCCB.MCCB shall be provided with double insulation(insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open)Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.160 A 25 kA with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 14119.35 | 14119.35 | 2.0 | False | None | None | False | None | False | 28238.7 | 0 |
2438911 | 73390 | None | code71 | Supplying and fixing Moulded Case Circuit Breaker(MCCB) over theexisting wood/panel board using necessary screws,bolts,nuts,necessary phase separators,handle and wiring complete.Protection of Over load and Short circuit with adjustable thermal magnetic release,Microprocessor release shall have Earth Fault as per IS/IEC60947 2.(Icu=100%lcs).In 4P MCCB,all Poles should have protection for Short Cicrcuit / Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non Priority loads must be available in the MCCB.MCCB shall be provided with double insulation(insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open)Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.125 A 25 kA with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 10858.05 | 10858.05 | 4.0 | False | None | None | False | None | False | 43432.2 | 0 |
2438912 | 73390 | None | code72 | Supplying and fixing of Shunt trip suitable for MCCB.CBCT with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 1788.15 | 1788.15 | 2.0 | False | None | None | False | None | False | 3576.3 | 0 |
2438913 | 73390 | None | code73 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 Amps SP. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 435.75 | 435.75 | 40.0 | False | None | None | False | None | False | 17430.0 | 0 |
2438914 | 73390 | None | code74 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 Amps DP with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 775.95 | 775.95 | 6.0 | False | None | None | False | None | False | 4655.7 | 0 |
2438915 | 73390 | None | code75 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 Amps TPN. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 1802.85 | 1802.85 | 5.0 | False | None | None | False | None | False | 9014.25 | 0 |
2438916 | 73390 | None | code76 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.50-63 Amps TPN. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 3242.4 | 3242.4 | 43.0 | False | None | None | False | None | False | 139423.2 | 0 |
2438917 | 73390 | None | code77 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure.II - Double Door 16 Way SP & N with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 3053.4 | 3053.4 | 1.0 | False | None | None | False | None | False | 3053.4 | 0 |
2438918 | 73390 | None | code78 | Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V up to 300mA sensitivity on existing wood/panel board 63 Amps 4 pole with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 5822.25 | 5822.25 | 1.0 | False | None | None | False | None | False | 5822.25 | 0 |
2438919 | 73390 | None | code79 | Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 9717.75 | 9717.75 | 2.0 | False | None | None | False | None | False | 19435.5 | 0 |
2438920 | 73390 | None | code80 | Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 9780.75 | 9780.75 | 2.0 | False | None | None | False | None | False | 19561.5 | 0 |
2438921 | 73390 | None | code81 | Supplying, fixing and wiring 1000/5A to 1600/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 882.0 | 882.0 | 2.0 | False | None | None | False | None | False | 1764.0 | 0 |
2438922 | 73390 | None | code82 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 540.75 | 540.75 | 36.0 | False | None | None | False | None | False | 19467.0 | 0 |
2438923 | 73390 | None | code83 | Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete.100Amps 4x30x6mm Aluminium Strips with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Mtr | 2588.25 | 2588.25 | 6.0 | False | None | None | False | None | False | 15529.5 | 0 |
2438924 | 73390 | None | code84 | Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete.250Amps 4x30x10mm Aluminium Strips with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Mtr | 3606.75 | 3606.75 | 8.0 | False | None | None | False | None | False | 28854.0 | 0 |
2438925 | 73390 | None | code85 | Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete.1000 A double run of 4 x 60 x 10 mm Aluminium Strips with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Mtr | 11109.0 | 11109.0 | 8.0 | False | None | None | False | None | False | 88872.0 | 0 |
2438926 | 73390 | None | code86 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.40*40*6mm with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Mtr | 320.25 | 320.25 | 24.0 | False | None | None | False | None | False | 7686.0 | 0 |
2438927 | 73390 | None | code87 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.50x50x6mm with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Mtr | 414.75 | 414.75 | 24.0 | False | None | None | False | None | False | 9954.0 | 0 |
2438928 | 73390 | None | code88 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.75 x 75 x 6 mm with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Mtr | 582.75 | 582.75 | 12.0 | False | None | None | False | None | False | 6993.0 | 0 |
2438929 | 73390 | None | code89 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.50X100X50X6mm C channel with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Mtr | 793.8 | 793.8 | 24.0 | False | None | None | False | None | False | 19051.2 | 0 |
2438930 | 73390 | None | code90 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.75 x 150 x 75 x 6 mm C channel with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Mtr | 972.3 | 972.3 | 12.0 | False | None | None | False | None | False | 11667.6 | 0 |
2438931 | 73390 | None | code91 | Supplying and fixing of 3 pole power contactor with NO/NC contacts on existing wood/panel boaard using necessary bolts,nuts, washers and wiring etc., completee with ac-3 rating and as per IS-13947 60Amps. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 6247.5 | 6247.5 | 7.0 | False | None | None | False | None | False | 43732.5 | 0 |
2438932 | 73390 | None | code92 | Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 V grade, for power factor improvement of rotating machineries likeinduction motor. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Kvar | 504.0 | 504.0 | 175.0 | False | None | None | False | None | False | 88200.0 | 0 |
2438933 | 73390 | None | code93 | Supplying, fixing and wiring Automatic Power Factor controller circuit unit fully, static units controlled by 14 stage microprocessor operation, relays LED display, self programming function for power stages and operating logic checking facility for healthy and efficient of each individual capacitor bank, measurement of network harmonics with indication when limit values are exceeded, Comprehensive displays with large, three phase LED display, Long term memory for settings, protection for over voltage, power factor correction fault and no voltage, to connect/ disconnect banks, with automatic recognition or with standard programs. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 22722.0 | 22722.0 | 1.0 | False | None | None | False | None | False | 22722.0 | 0 |
2438934 | 73390 | None | code94 | Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete.14SWG with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Sq CM | 0.52 | 0.52 | 425000.0 | False | None | None | False | None | False | 221000.0 | 0 |
2438935 | 73390 | None | code95 | Supply and fixing of Auxiliary contactor relay with 2 NO and 2 NC contact and operating coil voltage of 220V to 260V. fixed on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Each | 1396.5 | 1396.5 | 4.0 | False | None | None | False | None | False | 5586.0 | 0 |
2438936 | 73390 | None | code96 | Supplying,fixing,wiring,earth electrode for grounding conduits,I.C.cutouts and other equipment's on the mete rboard using 40mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit.The pit should be filled with equal proportion of salt and char coal150mm all-round the pipe to complete depth.The connection from the pipe to the conduit etc.,is to be established through GI wire of size as per lSI specification7.3.3.of IS732 using 12 mm dia bolts,nuts,washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 3685.5 | 3685.5 | 8.0 | False | None | None | False | None | False | 29484.0 | 0 |
2438937 | 73390 | None | code97 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. GI strip GI Strip. 25x3mm with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Mtr | 86.1 | 86.1 | 40.0 | False | None | None | False | None | False | 3444.0 | 0 |
2438938 | 73390 | None | code98 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. GI strip Copper strip. 25x3mm. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Mtr | 598.5 | 598.5 | 20.0 | False | None | None | False | None | False | 11970.0 | 0 |
2438939 | 73390 | None | code99 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600x600x3mm Copper plate. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 7792.05 | 7792.05 | 2.0 | False | None | None | False | None | False | 15584.1 | 0 |
2438940 | 73390 | None | code100 | Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG. Copper Wire with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Mtr | 110.25 | 110.25 | 200.0 | False | None | None | False | None | False | 22050.0 | 0 |
2438941 | 73390 | None | code101 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 1.5sqmm with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 3.15 | 3.15 | 4.0 | False | None | None | False | None | False | 12.6 | 0 |
2438942 | 73390 | None | code102 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 2.5sqmm with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 4.2 | 4.2 | 10.0 | False | None | None | False | None | False | 42.0 | 0 |
2438943 | 73390 | None | code103 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 4sqmm with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 7.35 | 7.35 | 8.0 | False | None | None | False | None | False | 58.8 | 0 |
2438944 | 73390 | None | code104 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 6sqmm with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 7.35 | 7.35 | 9.0 | False | None | None | False | None | False | 66.15 | 0 |
2438945 | 73390 | None | code105 | Providing and laying in position 100mm dia stone ware pipe in existing trench. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Mtr | 225.75 | 225.75 | 100.0 | False | None | None | False | None | False | 22575.0 | 0 |
2438946 | 73390 | None | code106 | Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.15" Sweep (450mm) with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 1566.6 | 1566.6 | 1.0 | False | None | None | False | None | False | 1566.6 | 0 |
2438947 | 73390 | None | code107 | Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS:1709/1984 with latest amendment, Rated voltage 220 V/ 50 Hz, Rated power input 48 W Plus / minus 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 Plus / minus 10% RPM, Rated air delivery 210Plus / minus 10% Cubic Meter Minimum, Rated service value Greater than or Equal to 4.2 CMM / Watt, Three Blades of blade leaf 1.05mm thick Aluminium Alloy sheet, Class B motor insulation,Bearing Two ball bearings, Top 6202, Bottom 6201 , as per IS specification, Motor wdg. Temp rise Shall not exceed 75 degC over and ambient of 40 0C by resistance method at 245Volts, Insulation resistance Shall not be less than Two Mega Ohms (2 M Ohms), Leakage current Should not exceed 210Micro Amp, Power input, watt& current , Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty48" Sweep 5 Star (1200mm) with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 4518.15 | 4518.15 | 4.0 | False | None | None | False | None | False | 18072.6 | 0 |
2438948 | 73390 | None | code108 | Supplying wall mounting fan suitable to operate at singlephase.400mm Sweep 230v A.C. supply. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 3372.6 | 3372.6 | 1.0 | False | None | None | False | None | False | 3372.6 | 0 |
2438949 | 73390 | None | code109 | Supplying of ......feet - PVC Batten with integrated LED tube.....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fighting 1 x 2' - 9/10w. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 578.55 | 578.55 | 2.0 | False | None | None | False | None | False | 1157.1 | 0 |
2438950 | 73390 | None | code110 | Supplying of ......feet - PVC Batten with integrated LED tube.....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fighting 1 x4'- 20/22 w. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 724.5 | 724.5 | 6.0 | False | None | None | False | None | False | 4347.0 | 0 |
2438951 | 73390 | None | code111 | Supplying of recess/surface mounting non integrated type LED down light ...... W luminaire comprising of pressure decast/ extruded aluminium housing, with spring loaded false ceiling clamps, LED of Power/COB with CCT 6500 degree K, CRIgreater than 70%. efficacy greater than100 lumen per watt, 120degree beam spread, lifegreater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF greater than0.95, power loss should Less than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit,THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.15-18W. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 1754.55 | 1754.55 | 49.0 | False | None | None | False | None | False | 85972.95 | 0 |
2438952 | 73390 | None | code112 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation.Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT greater than 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with W System Power consumption. LED Efficiency greater than130lm/w, nominal CRI greater than 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source.LED Streetlight 40W. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 4225.2 | 4225.2 | 8.0 | False | None | None | False | None | False | 33801.6 | 0 |
2438953 | 73390 | None | code113 | Supplying and Fixing........mm dia class A GI pipe bracket up to 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed forfixing MV/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/tubular pole, using suitable clamps, bolts, nuts and wiring using suitable capacity wires. Using 25mm dia G.I.Pipe. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 1263.15 | 1263.15 | 8.0 | False | None | None | False | None | False | 10105.2 | 0 |
2438954 | 73390 | None | code114 | Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 170.1 | 170.1 | 8.0 | False | None | None | False | None | False | 1360.8 | 0 |
2438955 | 73390 | None | code115 | Fixing all types and all capacities of fluorescent / false ceiling/ spot light / CFL / LED fittings indoor on the wall / ceiling /rafters / girders using 23/0.0076” twin twisted PVC insulatedwires, required Nos of round blocks and clamps.On wall/ ceiling / Rafter / Girders.with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 128.1 | 128.1 | 57.0 | False | None | None | False | None | False | 7301.7 | 0 |
2438956 | 73390 | None | code116 | Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 330.75 | 330.75 | 5.0 | False | None | None | False | None | False | 1653.75 | 0 |
2438957 | 73390 | None | code117 | Fixing one exhaust fan after making a suitable notch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 A, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 742.35 | 742.35 | 1.0 | False | None | None | False | None | False | 742.35 | 0 |
2438958 | 73390 | None | code118 | 2 mm thick perforated cable GI tray with on existing MS angle support using necessary GI bolts/nuts and washer or welding as required.450 x 50 mm with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Mtr | 958.65 | 958.65 | 100.0 | False | None | None | False | None | False | 95865.0 | 0 |
2438959 | 73390 | None | code119 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975. 16 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm) with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Km | 148934.1 | 148934.1 | 0.75 | False | None | None | False | None | False | 111700.575 | 0 |
2438960 | 73390 | None | code120 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff.2.5 to 25 Sqmm with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Km | 21930.3 | 21930.3 | 0.75 | False | None | None | False | None | False | 16447.725 | 0 |
2438961 | 73390 | None | code121 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975.185 Sqmm, 3.5 Core, (28 GI Strips - 4 x 0.8 mm) with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Km | 725778.9 | 725778.9 | 0.75 | False | None | None | False | None | False | 544334.175 | 0 |
2438962 | 73390 | None | code122 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff.120 to 240 Sqmm with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Km | 33891.9 | 33891.9 | 0.75 | False | None | None | False | None | False | 25418.925 | 0 |
2438963 | 73390 | None | code123 | Heavy Duty Copper Terminal Long Barrel.16/25 Sqmm Copper Terminal, Apprx Wt: 11 Gm. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 28.35 | 28.35 | 128.0 | False | None | None | False | None | False | 3628.8 | 0 |
2438964 | 73390 | None | code124 | Heavy Duty Copper Terminal Long Barrel.185 Sqmm Copper Terminal, Apprx Wt: 158 Gm. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 287.7 | 287.7 | 80.0 | False | None | None | False | None | False | 23016.0 | 0 |
2438965 | 73390 | None | code125 | Brass Cable Gland 25mm. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 82.95 | 82.95 | 16.0 | False | None | None | False | None | False | 1327.2 | 0 |
2438966 | 73390 | None | code126 | Brass Cable Gland 40mm. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 155.4 | 155.4 | 20.0 | False | None | None | False | None | False | 3108.0 | 0 |
2438967 | 73390 | None | code127 | Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr (BESCOM SR PART-4,P.NO.8, IT No-29.02) -Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Cum | 508.2 | 508.2 | 112.5 | False | None | None | False | None | False | 57172.5 | 0 |
2438968 | 73390 | None | code128 | Refilling the cable trenches with selected available earth from trench excavation including watering, consolidation in layers of 15 cm. Thickness including depositing of the surplus earth with a lead of 200 Mtr. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Cum | 60.9 | 60.9 | 112.5 | False | None | None | False | None | False | 6851.25 | 0 |
2438969 | 73390 | None | code129 | Supply of DP Structure using RCC Pole - 9 Mtr Long, 145 Kg WL (Including Cost of Poles). with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Set | 21974.4 | 21974.4 | 2.0 | False | None | None | False | None | False | 43948.8 | 0 |
2438970 | 73390 | None | code130 | fixing of DP Structure using RCC Pole - 9 Mtr Long, 145 Kg WL (Including Cost of Poles). with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Set | 5640.6 | 5640.6 | 2.0 | False | None | None | False | None | False | 11281.2 | 0 |
2438971 | 73390 | None | code131 | Supply of 11 kV, 45 KN Polymeric Insulator. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 195.3 | 195.3 | 12.0 | False | None | None | False | None | False | 2343.6 | 0 |
2438972 | 73390 | None | code132 | Supply of Guy Set Complete with No. 15 Strain Insulator & Concreting materials.Supply of Guy Clamp - GI. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 120.75 | 120.75 | 4.0 | False | None | None | False | None | False | 483.0 | 0 |
2438973 | 73390 | None | code133 | Supply of Turn Buckle GI with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 253.05 | 253.05 | 4.0 | False | None | None | False | None | False | 1012.2 | 0 |
2438974 | 73390 | None | code134 | Supply of Anchor Rod using 12 mm rounds/Guy Rod - GI. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 345.45 | 345.45 | 4.0 | False | None | None | False | None | False | 1381.8 | 0 |
2438975 | 73390 | None | code135 | Supply of No. 15 Strain Insulator. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 61.95 | 61.95 | 4.0 | False | None | None | False | None | False | 247.8 | 0 |
2438976 | 73390 | None | code136 | Supply of Guy Wire & GI Wire as per IS-2141.7/10 SWG Guy Wire(7/3.251 mm Dia), Std Wt: 680 Kg/KM. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | MT | 81087.3 | 81087.3 | 0.01 | False | None | None | False | None | False | 810.873 | 0 |
2438977 | 73390 | None | code137 | Digging of Pit for GUY SET.Ordinary Soil. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Per Pit | 343.35 | 343.35 | 4.0 | False | None | None | False | None | False | 1373.4 | 0 |
2438978 | 73390 | None | code138 | Fixing of GUY Set with break insulator making use of 7/3.15 mm (7/10 SWG) galvanised steel wire with turn buckle and anchoring arrangement as per approved drawing. (Excluding excavation of PIT) with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Per Set | 279.3 | 279.3 | 4.0 | False | None | None | False | None | False | 1117.2 | 0 |
2438979 | 73390 | None | code139 | supply of Spiral Earth Electrode. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 250.95 | 250.95 | 4.0 | False | None | None | False | None | False | 1003.8 | 0 |
2438980 | 73390 | None | code140 | Providing Spiral Earth Electrode type earthing. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 97.65 | 97.65 | 4.0 | False | None | None | False | None | False | 390.6 | 0 |
2438981 | 73390 | None | code141 | Supply of Caution/Danger Board. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 157.5 | 157.5 | 2.0 | False | None | None | False | None | False | 315.0 | 0 |
2438982 | 73390 | None | code142 | fixing of Caution/Danger Board. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 84.0 | 84.0 | 2.0 | False | None | None | False | None | False | 168.0 | 0 |
2438983 | 73390 | None | code143 | Supply of Anti Climbing Device (12 Mtr GI Barbed Wire). with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Each | 93.45 | 93.45 | 4.0 | False | None | None | False | None | False | 373.8 | 0 |
2438984 | 73390 | None | code144 | fixing of Anti Climbing Device (12 Mtr GI Barbed Wire). with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Each | 44.1 | 44.1 | 4.0 | False | None | None | False | None | False | 176.4 | 0 |
2438985 | 73390 | None | code145 | Supply of 11 kV, 400 Amps Double Break GOS with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Set | 22323.0 | 22323.0 | 2.0 | False | None | None | False | None | False | 44646.0 | 0 |
2438986 | 73390 | None | code146 | Fixing of GOS including wiring (11 kV Double Break 400 Amps).with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Set | 1274.7 | 1274.7 | 2.0 | False | None | None | False | None | False | 2549.4 | 0 |
2438987 | 73390 | None | code147 | Supply of Single H Frame without Transformer Seating and Seating angle support cross arm for 11 Mtr Spun Pole for 63/100/250/500kVA (OH Line) - GI. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 18886.35 | 18886.35 | 2.0 | False | None | None | False | None | False | 37772.7 | 0 |
2438988 | 73390 | None | code148 | Erection of H-Frame.for mounting GOS. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 339.15 | 339.15 | 2.0 | False | None | None | False | None | False | 678.3 | 0 |
2438989 | 73390 | None | code149 | Supply of 11 kV, DOLO Cutout Conventional to Erstwhile KEB Specification. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Set | 6168.75 | 6168.75 | 2.0 | False | None | None | False | None | False | 12337.5 | 0 |
2438990 | 73390 | None | code150 | Fixing DOLO Cutout/Horn Gap Fuse including fixing of cross arm and wiring. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Set | 248.85 | 248.85 | 2.0 | False | None | None | False | None | False | 497.7 | 0 |
2438991 | 73390 | None | code151 | Supply of 11 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975. 95 Sqmm, (54 GI Wires - 2.5 mm Dia). with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Km | 934149.3 | 934149.3 | 0.4 | False | None | None | False | None | False | 373659.72 | 0 |
2438992 | 73390 | None | code152 | Supply of Heat Shrinkable Indoor Type Cable Termination Kit for XLPE Cable.3Cx95sqmm indoor. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Kit | 3931.2 | 3931.2 | 3.0 | False | None | None | False | None | False | 11793.6 | 0 |
2438993 | 73390 | None | code153 | Supply of Heat Shrinkable Outdoor Type Cable Termination Kit for XLPE Cable 3Cx95sqmm outdoor. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Kit | 4270.35 | 4270.35 | 3.0 | False | None | None | False | None | False | 12811.05 | 0 |
2438994 | 73390 | None | code154 | Supply of Cable covering tiles 250x125x40mm.. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 10.76 | 10.76 | 150.0 | False | None | None | False | None | False | 1614.0 | 0 |
2438995 | 73390 | None | code155 | Supply of River sand. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Cum | 1549.8 | 1549.8 | 6.0 | False | None | None | False | None | False | 9298.8 | 0 |
2438996 | 73390 | None | code156 | Supply of RCC humepipes 2000mm long 150mm dia. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 322.35 | 322.35 | 10.0 | False | None | None | False | None | False | 3223.5 | 0 |
2438997 | 73390 | None | code157 | Supply of Collars for RCC hume pipes. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 86.1 | 86.1 | 10.0 | False | None | None | False | None | False | 861.0 | 0 |
2438998 | 73390 | None | code158 | Supply of GI pipe 150mm dia. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Mtr | 1072.05 | 1072.05 | 20.0 | False | None | None | False | None | False | 21441.0 | 0 |
2438999 | 73390 | None | code159 | Supply of Route and Joint indicating stones with MS Anchor rod. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 139.65 | 139.65 | 50.0 | False | None | None | False | None | False | 6982.5 | 0 |
2439000 | 73390 | None | code160 | Earth work excavation for cable treanch of 0.5 to 0.75Mtr Width and Depth up to 1Mtr .BESCOM SR PART-4,PAGE-8,ITEAM NO-29.02 -Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Cum | 508.2 | 508.2 | 30.0 | False | None | None | False | None | False | 15246.0 | 0 |
2439001 | 73390 | None | code161 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff.3x95 to 150 Sqmm. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Km | 64388.1 | 64388.1 | 0.4 | False | None | None | False | None | False | 25755.24 | 0 |
2439002 | 73390 | None | code162 | Retailing the cable trenches with selected availble earth from trench excavation including watering,Consolidation in layers of 15Cm thickness including depositing of the surplus earth with a lead of 200Mtrs. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Cum | 60.9 | 60.9 | 40.0 | False | None | None | False | None | False | 2436.0 | 0 |
2439003 | 73390 | None | code163 | Making and Fixing pot head for HT Cable only.Heat shrinkable Type Terminations.3x95 to 3x150 Sqmm. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 2790.9 | 2790.9 | 4.0 | False | None | None | False | None | False | 11163.6 | 0 |
2439004 | 73390 | None | code164 | Covering the cables with tiles. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Km | 4585.35 | 4585.35 | 0.4 | False | None | None | False | None | False | 1834.14 | 0 |
2439005 | 73390 | None | code165 | Spreading and forming with sand alround the cable to a depth of 75mm and width of 500mm . with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Km | 15550.5 | 15550.5 | 0.4 | False | None | None | False | None | False | 6220.2 | 0 |
2439006 | 73390 | None | code166 | Laying and Jointing the pipes (100-150 mm Dia) including lowering in Position: Fixing Collars etc., Joining with mud mortor complete.RCC Pipe.. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Mtr | 72.45 | 72.45 | 10.0 | False | None | None | False | None | False | 724.5 | 0 |
2439007 | 73390 | None | code167 | Laying the GI Pipe 80 mm to 150 mm dia at Drainage Water Supply Crossing including fixing collars elbows, bends, Tees and other fitting with Cuts and Threads wherever necessary complete.. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Mtr | 97.65 | 97.65 | 20.0 | False | None | None | False | None | False | 1953.0 | 0 |
2439008 | 73390 | None | code168 | Fixing of Route Joint Indicating Slab.. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 121.8 | 121.8 | 50.0 | False | None | None | False | None | False | 6090.0 | 0 |
2439009 | 73390 | None | code169 | 11kV HT Metering cubical of different CT Ratio Both side entry type with 3CT & 3PTs with transparent cover TTB,with 30x8mm Copper Bus bars,modem and 2nos of Meters for 3 Phase 4 Wire Metering WITHOUT Load break Switch (HT Metering Box Fabricated out of 3mm MS Sheet duly epoxy powder coated)as per revised specification..with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 255645.6 | 255645.6 | 1.0 | False | None | None | False | None | False | 255645.6 | 0 |
2439010 | 73390 | None | code170 | Load Break switches with Panel. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 76900.95 | 76900.95 | 1.0 | False | None | None | False | None | False | 76900.95 | 0 |
2439011 | 73390 | None | code171 | Erection of HT metering Cubicle on Platform. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 1936.2 | 1936.2 | 1.0 | False | None | None | False | None | False | 1936.2 | 0 |
2439012 | 73390 | None | code172 | Erection Alignment and fixing of Load break switch on the platform. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 2181.9 | 2181.9 | 1.0 | False | None | None | False | None | False | 2181.9 | 0 |
2439013 | 73390 | None | code173 | Construction of platform (1.5x1.5x1.2) mtr in size stone,cement concrete for erection of Metering cubical,Transformer and Load break switch: Excavation of (1.5x1.5x1) mt pit for foundation providing and laying cement concrete 1:4:8 for foundation laid in 10cm thick layers, well compacted curing etc., complete providing and construction of stone masonary 0.9m below ground level and 1.2m above ground level neatly hammer dressed in cement morter 1:6. Providing cement concrete Slab(1.5x1.5x0.10)Mtr with cement concrete 1:2:4 mix forming and cutting complete providing pointing to stone masonary in cement morter 1:3 after racking joint & nisely lining curing etc., plastering the concrete surfaces in cement morter 1:4 including smooth randering curing etc., curing at every stages completely with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 22844.85 | 22844.85 | 3.0 | False | None | None | False | None | False | 68534.55 | 0 |
2439014 | 73390 | None | code174 | Distribution Transformer - 3 Phase, 11kV/433V - Stacked CRGO Core with Oil as per IS-1180 (Part-1): 2014.21. 500 kVA, Aluminium Wdg, Star 2 (5 Star). with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 959467.95 | 959467.95 | 1.0 | False | None | None | False | None | False | 959467.95 | 0 |
2439015 | 73390 | None | code175 | Erection of 300 - 500 kVA Transformer. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 3239.25 | 3239.25 | 1.0 | False | None | None | False | None | False | 3239.25 | 0 |
2439016 | 73390 | None | code176 | Providing chain link fencing 50mm size of 8 guage properly stretched between rectangular poles and fixed with suitable bolts & nuts, the free ends shall be welded to the pole and block pipe at top and bottom as required including cost of all materials, labour, lead and lifts, cutting, bending wherever necessary, wastage and lapping etc., complete as per the direction of the engineer incharge for work including two coats of approved quality paint over one coat of primer paint. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Sqm | 274627.5 | 274627.5 | 1.0 | False | None | None | False | None | False | 274627.5 | 0 |
2439017 | 73390 | None | code177 | Supplying,fixing,wiring,earth electrode for grounding conduits,I.C.cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5m long buried in a pit.The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth.The connection from the pipe to the conduit etc.,is tobe established through GI wire of size as per lSI specification 7.3.3.of IS732 using 12 mm dia bolts,nuts,washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 3685.5 | 3685.5 | 6.0 | False | None | None | False | None | False | 22113.0 | 0 |
2439018 | 73390 | None | code178 | Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | No | 4468.8 | 4468.8 | 10.0 | False | None | None | False | None | False | 44688.0 | 0 |
2439019 | 73390 | None | code179 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. GI strip GI Strip. 25x3mm with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Mtr | 86.1 | 86.1 | 60.0 | False | None | None | False | None | False | 5166.0 | 0 |
2439020 | 73390 | None | code180 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. GI strip 50x6mm GI strip with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Mtr | 228.9 | 228.9 | 30.0 | False | None | None | False | None | False | 6867.0 | 0 |
2439021 | 73390 | None | code181 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25 x 3 mm Copper strip with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Mtr | 598.5 | 598.5 | 20.0 | False | None | None | False | None | False | 11970.0 | 0 |
2439022 | 73390 | None | code182 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25 x 6 mm Copper strip with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Mtr | 1155.0 | 1155.0 | 20.0 | False | None | None | False | None | False | 23100.0 | 0 |
2439023 | 73390 | None | code183 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required.600 x 600 x 3 mm Copper plate with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Mtr | 7792.05 | 7792.05 | 6.0 | False | None | None | False | None | False | 46752.3 | 0 |
2439024 | 73390 | None | code184 | Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG. Copper Wire with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Mtr | 60.9 | 60.9 | 50.0 | False | None | None | False | None | False | 3045.0 | 0 |
2439025 | 73390 | None | code185 | Open Conduit System Supplying heavy gauge PVC conduit pipe …….dia .......mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.25mm dia 2mm thick. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Mtr | 85.0 | 85.0 | 430.0 | False | None | None | False | None | False | 36550.0 | 0 |
2439026 | 73390 | None | code186 | Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete.upto 50mm conduit in brick wall with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Mtr | 30.0 | 30.0 | 20.0 | False | None | None | False | None | False | 600.0 | 0 |
2439027 | 73390 | None | code187 | Supplying and drawing of 2 CoreX1.5 Sqmm coppe rconductor armoured cable with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Mtr | 158.0 | 158.0 | 440.0 | False | None | None | False | None | False | 69520.0 | 0 |
2439028 | 73390 | None | code188 | Supply,installation,testing and commissioning of analogue addressable Smoke Sensor detector and standard base(ForDetectors/Device without in built isolator,Fault Isolator or Isolator base to be provided with each detector/device) Approval VDS/UL/EN54.with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Each | 3465.0 | 3465.0 | 54.0 | False | None | None | False | None | False | 187110.0 | 0 |
2439029 | 73390 | None | code189 | Supplying Installing, testing and commissioning of Response Indictor constists of twin LED wioth electronic circutarx work on 24 DC enclose in PVC retangular. complete including cost of materials, labour, usage charges of machinery complete as per specifications.with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Each | 263.0 | 263.0 | 54.0 | False | None | None | False | None | False | 14202.0 | 0 |
2439030 | 73390 | None | code190 | Supplying Installing, testing and commissioning of electronic Hooter, it conists of electronic circuit to give dual Fire alaram sound with works.24V DC with speaker all encased in suitable in MS 16 gauge red painted box.complete including cost of materials,labour,usage charges of machinery complete as per specifications.with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Each | 1575.0 | 1575.0 | 1.0 | False | None | None | False | None | False | 1575.0 | 0 |
2439031 | 73390 | None | code191 | Supplying Installing, testing and commissioning of Resettable type Manual Call point . works on 24V DC LED indicator with glass Fronted. Fire Symbol .The red Manual Call Point is approved to EN54-11 standard. MECHANICAL CONSTRUCTION The component parts of the call point are moulded in polycarbonate or ABS, depending on their function.with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Each | 1575.0 | 1575.0 | 1.0 | False | None | None | False | None | False | 1575.0 | 0 |
2439032 | 73390 | None | code192 | Supplying and fixing sheet metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc. including cost of materials, labour, usage charges of machinery complete as per specifications.with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Each | 158.0 | 158.0 | 6.0 | False | None | None | False | None | False | 948.0 | 0 |
2439033 | 73390 | None | code193 | Addresable Smoke Detection- Wired.Supply, install, test and commissioning of addressable peer to peer Networkable analogue addressable type fire alarm control panel with minimum 1500 Character / 240X64 Pixel / 7inch Touchscreen graphic LCD display. The panel should be equipped with sufficient numbers of loop with 20% spare capacity, with each networkable intelligent fire alarm Control Panel having SLC with capacity of min 126 /240 detectors/ devices in any combination with key pad, dual flash-based microprocessor technology, inbuilt USB Port for upload and down load the configuration tools, RS232 serial port for direct PC or modem connection, inbuilt NAC's, min 20 programmable Zonal LEDs and operates on 240V AC + 10% with 50 Hz with built in charger. The panel shall have fire, fault relays, option of BMS integration MODBUS/ BACKNET, graphical software for provision of TCP/ IP modules, Remote Access, Class 'X' wiring with provision of both class 'A' and class 'B' wiring in the SLC circuit, user friendly with communication facility to monitor & control the FACPs from a single window. The panel shall be suitable for minimum of 5000 event record facility, event fetch from FACP facility and the single panel shall be suitable for min 2000 fire zones and 200 Panels/ Nodes in one network with all other accessories required to successfully run the system. (The System cost shall be included of all necessary cards, modules, Panel enclosure, CPU and associated accessories to complete the system design). Approval: VDS/UL/EN-54 Std. Make:Advanced (UK), Argus,( Uk) Simplex, Notifie 2 Loop Panel with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Each | 220500.0 | 220500.0 | 1.0 | False | None | None | False | None | False | 220500.0 | 0 |
2439034 | 73390 | None | code194 | Providing and Fixing Fire force board size of 3'x2' made out to Acrylic sheet of 3mm thick and fixing with Stainless Steel finished studs etc.complete including cost of materials,labour,usage charges of machinery complete as per specifications..with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Mtr | 2625.0 | 2625.0 | 1.0 | False | None | None | False | None | False | 2625.0 | 0 |
2439035 | 73390 | None | code195 | Supplying Installing,testing and commissioning of Public address system(Two way comminication type)as per requirement of Fire Force authority and which Generally comprise of Supplying Installing,testing and commissioning of Approved make 6W.wall mounted speaker with talk back facility with store enamel painted M.S.Sheet hosing etc.complete including cost of materials,labour,usage charges of machinery complete as per specifications.with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Each | 2573.0 | 2573.0 | 1.0 | False | None | None | False | None | False | 2573.0 | 0 |
2439036 | 73390 | None | code196 | Supplying Installing,testing and commissioning of P.A.System console panel with push button with speaker and indictor on Accomdated in M.S.Cabinet with painting including cost of materials,labour,usage charges of machinery complete as per specifications.10 Zone cansole.with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Each | 36750.0 | 36750.0 | 1.0 | False | None | None | False | None | False | 36750.0 | 0 |
2439037 | 73390 | None | code197 | P.A.System amplifier 250W RMS output with complete wiring and controls accessable form front with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Each | 37013.0 | 37013.0 | 1.0 | False | None | None | False | None | False | 37013.0 | 0 |
2439038 | 73390 | None | code198 | Supplying Installing,testing and commissioning of MIKEsuitable to I.A.System. Complete.t with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Each | 5775.0 | 5775.0 | 1.0 | False | None | None | False | None | False | 5775.0 | 0 |
2439039 | 73390 | None | code199 | Supplying of four bucket stand along with buckets. Complete.with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Each | 1943.0 | 1943.0 | 1.0 | False | None | None | False | None | False | 1943.0 | 0 |
2439040 | 73390 | None | code200 | Supplying of Hand gloves. Complete..with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Each | 1024.0 | 1024.0 | 2.0 | False | None | None | False | None | False | 2048.0 | 0 |
2439041 | 73390 | None | code201 | Supplying of first aid box. Complete.with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Each | 630.0 | 630.0 | 1.0 | False | None | None | False | None | False | 630.0 | 0 |
2439042 | 73390 | None | code202 | Supplying of SAFETY MASK. Complete.with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Each | 158.0 | 158.0 | 2.0 | False | None | None | False | None | False | 316.0 | 0 |
2439043 | 73390 | None | code203 | Supplying of FIRST AID CHART with lamination.Complete with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Each | 420.0 | 420.0 | 1.0 | False | None | None | False | None | False | 420.0 | 0 |
2439044 | 73390 | None | code204 | Supplying and installation of RUBBER MAT 1mtrx1mtr-1Omm thick.complete including cost of materials,labour,usage charges of machinery complete as per specifications.with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Each | 1995.0 | 1995.0 | 1.0 | False | None | None | False | None | False | 1995.0 | 0 |
2439045 | 73390 | None | code205 | Providing ABC Powder based MAP 50, 2Kg.Providing 2kg Fire Extinguisher Mono Ammonium Phosphate Powder 50, Stored Pressure Type, Pressure Gauge, Gross Weight 3.6 Kg, empty weight 1.6 Kg, Can Height 344MM, Diameter 108MM, Discharge Time less than 8 Sees, Controllable discharge mechanism (Squeeze grip with easy snap safety seal),Range minimum 2 meters, applicable on Class A,8, C and electrically started Fire, A Rating 1A, 8 Rating 88, Can construction : Deep drawn & Co. , Mig welded, valve Construciton: Forging and Mechining, Internal Coating of Can: Epoxy powder coating, External Coating of Can: Epoxy PoIyster power coating, Sheet metal thickness: 1.60MM, 5years Warranty with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost of materials, labour, usage charges of machinery complete as per specifications. complete. IS 15683, CE Approved..with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Each | 2205.0 | 2205.0 | 4.0 | False | None | None | False | None | False | 8820.0 | 0 |
2439046 | 73390 | None | code206 | Providing's Escape Singage Photo lumines centrigid plastic,2mm thickness,Printed on High Quality glass paint with UV resistance,5years warranty,Material Used-Non Radiocactive,non phosphorous,non toxic and lead free.Available in different types & sizes,Time after removing the light source (inminutes) 60minutes,Luminescent intensity (milicandelas*persquaremeter-mcd/sqm):30mcd/sqm.Luminescent Intensity greater than 0.32mcd/sqm,Period of Light Decay*(InMinutes):3100, including cost of materials,labour,usage charges of machinery complete as per specifications..with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Sq CM | 2625.0 | 2625.0 | 4.0 | False | None | None | False | None | False | 10500.0 | 0 |
2439047 | 73390 | None | code207 | Providing and Fixing evacuation plan of size A3 made out to Acrylic sheet of 3mm thick and fixing with Stainless Steel finished studs etc.complete including cost of materials,labour,usage charges of machinery complete as per specifications.with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Sq CM | 6825.0 | 6825.0 | 2.0 | False | None | None | False | None | False | 13650.0 | 0 |
2439048 | 73390 | None | code208 | Solar Photovoltaic Power Plant:-Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:- a) Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. c) Data Monitoring System complete with accessories. d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. e) Lightning and surge voltage protection. f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required.with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. | Set | 64113.0 | 64113.0 | 3.0 | False | None | None | False | None | False | 192339.0 | 0 |
2439049 | 73390 | None | code209 | Supplying, installing, testing and commissioning of PRIME Diesel Generator set with following specifications. Power rating as per standard reference condition as per-BS5514/ISO 3046/ISO 8528&IS 1002/ISO 3046 Generator set specifications.Engine: Diesel generating set are rated at 1500RPM and conform to ISO 8528 specifications. The engines are radiator cooled, four stroke and multi cylinder, conforming to ISO 3046. The scope of supply includes: Electrical starter motor 12V DC Battery charging alternator, Bosch fuel system with mechanical governor,A1 Class. Spin-on lube oil filter, Spin-on dual fuel filter with water separator, Turbocharger, Charge air cooler, Silencer (Hospital grade),Dry type air cleaner, Shutoff coil, Flywheel and flywheel housing, First fill of lube oil and coolant, Safety for low lube oil pressure, Safety for high water temperature, Permissible overload of 10% for one hour in 12 hours of operation.Capacity of Fuel Tank: Fuel tank suitable for 8 hours of operation.Mounting arrangement: Engine and alternator are mounted on a common MS fabricated base frame with AVM pads.Control Panel: The control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish. The control panel consists of the following parts:- PS0500 Controller, Aluminium bus bars with suitable capacity within/outgoing terminals, Indicating lamps for ‘Load On’ and ‘Set Running’ Instrument fuses duly wired and ferruled, MCCB of suitable rating with overload and short circuit protections.Genset Controller: microprocessor based generator set monitoring and control system. The control provides a simple operator interface to the generator set, manual and remote start/ stop control, shutdown fault indication, and an LCD hour counter. The integration of all functions into a single control system provides enhanced reliability and performance compared to conventional generator set control systems. This control has been designed and tested to meet harsh environment in which gensets are typically applied. Features, Functions, protections 16 characterx2 line alphanumeric LCD display with LED Backlight.Operator interface, Provide a record of most recent fault conditions. Fault history stored in the control non volatile memory, Provide Alternator Data. Voltage (1phor3ph line to line and line to neutral voltage, Current (1phor3ph),kVA (3phandtotal), Frequency, Provide Engine Data, Starting battery voltage, Engine running hours, Engine Temp, Engine oil pressure, Control includes provision for Service adjustment and calibration of DG control functions, Voltage, frequency selection, Configurable input and output set up, Meter calibration, Engine controls, Power Start operates on 12 VDC batteries,- Auto start mode accepts a ground signal from remote devices to automatically start the DG set. The remote start will also wake up the control system from sleep mode.Acoustic enclosure: The acoustic enclosure shall be made of 1.6 mm thick CRCA sheets in suitable approved shade and a structural/ sheet metal base frame painted in black. The walls of the enclosure are insulated with fire retardant foam so as to comply with the 75dBA at 1 mtr sound levels specified by Ministry of Environment & Forest. The enclosure has the following features: Specially designed to meet stringent MOEF/ CPCB norms of 75dBA@1mtr at 75% load under free field conditions, Two point lifting for easy handling at customer site, Designed to have optimum serviceability, Air inlet louvers specially designed to operate at rated load made on special purpose CNC machines for consistency in quality and workmanship, Powder coated for long lasting service life and superior finish, With UV resistant powder coating, can withstand extreme environment,Use of special hardware for longer life, Insulation material meets exacting IS 8183 specifications for better sound attenuation, Flush styling - no projections, As per actual for detailed technical specification | Set | 1678100.55 | 1678100.55 | 1.0 | False | None | None | False | None | False | 1678100.55 | 0 |
2439050 | 73390 | None | code210 | Supply installation testing and commissioning of plant and equipment for 2300 mt (approx.) capacity mutli commodity cold store with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work. (1)Ambient Temperature (in Deg C) 40 Deg C (2)Designed Room Temperature (plus / minus 2 Deg C ) (plus) 2 to (plus) 8 Deg C (3)Designed Room Humidity More than 90% RH (4)Product to be stored Fruits Vegetables, Chillies, and Pulses (5)Product Incoming Temperature (Deg C ) Plus 28 to 33 deg C (6) Product Room Temperature Deg C Plus 2 to 8 Deg C (7) Qty of Product stored per day/batch (in kg) apply 27000 kg / day (8) Pull down time (Hrs) 48 Hrs (9) Specific heat (Cp) Above Freezing (kJ/kg K) 4 kJ/kg K (10) Material of Insulation RPUF (12)Thickness of Insulation (mm) wall and ceiling 80 mm (13) Wall Lamination In / Out PPGI / PPGI (14) Ceiling (In/Out) PPGI/PPGI (14) Serration on panel To be Provided (15) Floor insulation RPUF PUF slab with Polysheet on both sides (16) Thickness of Insulation (mm) for floor 60mm (17)Size of Door 1800x2400 Ht mm PCGI Finish (18) Type of Door PUF Insulated manual sliding type (19) Type of refrigeration system Split Type-Individual Refrigeration system common for 1 pre cooling chambers and 8 cold storage rooms (20) Type of Cooling DX Type (21)Capacity of centralized refrigeration system 42 KW per room (22) Type of Refrigerant R404a (23) Type of Compressor Hermetic (24) Type of Condenser Air-Cooled (25) Capacity condensing unit To suit the Refrigeration System with R404A which can work from 3 degree C up to plus 10 degree evaporating temperature (26) Capacity of Evaporator unit 2x 21KW EACH room(Or to be suggested by manufacturer/bidder) (27) Number of Evaporator Units 16 UNITS Plus 2 FOR Pre cooling (28) Electrical Panel for Ref System To be Inbuilt in condensing unit (29) Type of evaporator units Forced Air Cooled (30) MOC for evaporator and Condenser units Ceiling suspended PPGI casing with tube axial fan (31) Temperature / humidity indicator-cum-controller Micro-Processor based controller (32) Lighting Inside the rooms Suitable for 50 Lux luminosity (33) Type of light fitting High bay LED (34) Interconnecting piping and wiring between the Condenser and Evaporator units As per actual as per drawing for detailed technical specification refer in annexure of KW4 bid document | Set | 30000000.0 | 30000000.0 | 1.0 | False | None | None | False | None | False | 30000000.0 | 0 |