createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1707201304174
version3
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee590.00
emd50000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose21-02-2024 16:00:00
tenderQueryClose19-02-2024 11:00:00
technicalBidOpen22-02-2024 16:30:00
publishedDate07-02-2024 19:23:22
publishedByPostPWD_EE_DIV_RCR
publishedByUserKPE15695 - K SHANKAR
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonChandrashekar TA
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08532225778
mobileNumberNone
tenderSupplierListNone
tenderSchedule
createdTs1707201304203
version4
createdDateNone
modifiedDateNone
tenderNumberPWD/2023-24/BD/WORK_INDENT8124
titleConstruction of Two Additional Room for Govt Higher Primary School at Rampur Village in Lingasugur Town of Raichur District Under KKRDB for the Year 2022-23 RCH231923341 GEN
descriptionConstruction of Two Additional Room for Govt Higher Primary School at Rampur Village in Lingasugur Town of Raichur District Under KKRDB for the Year 2022-23 RCH231923341 GEN
categoryWORKS
categoryTextWorks
ecv2351887.17
deptNamePublic Works Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location1695
locationNamePWD Division Office Raichuru
provisionalAmount2800000.0
groupOverheadTotal0.0
fileNumberAEE/PWD/SDL/SCHOOL/RAMPUR/2023-24
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17072013040001NoneNoneBuildingsConstruction of Two Additional Room for Govt Higher Primary School at Rampur Village in Lingasugur Town of Raichur District Under KKRDB for the Year 2022-23 RCH231923341 GEN2257710.57
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
245227774121NonePWD CSR VOL I year 2023-24.I. No.1.12 P.No.08Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.Cum99.7599.7545.0FalseNoneNoneFalseNoneFalse4488.750
245227874121NonePWD CSR VOL I year 2023-24. I. No.1.14.1 P.No.08Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the workCum107.1107.156.97FalseNoneNoneFalseNoneFalse6101.4870
245227974121NonePWD CSR VOL I year 2023-24. I. No. 1.4.1 P.No.05Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 mCum254.1254.116.59FalseNoneNoneFalseNoneFalse4215.5190
245228074121NonePWD CSR VOL I year 2023-24.I.No.1.23 P.No.11Providing and Filling in foundation with granite / trap broken metal 100mm. And down size & with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift complete as per specifications.Cum2816.12816.112.66FalseNoneNoneFalseNoneFalse35651.8260
245228174121NonePWD CSR VOL I year 2023-24. I. No. 2.1.3 P.No.15Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum6288.456288.4518.82FalseNoneNoneFalseNoneFalse118348.6290
245228274121NonePWD CSR VOL I year 2023-24. I. No. 2.1.4 P.No.15Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregatesCum6527.856527.851.42FalseNoneNoneFalseNoneFalse9269.5470
245228374121NonePWD CSR VOL I year 2023-24. Sl. No. 14 P.No.112Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Beams, Lintels & Troughs of Aqueducts 60%Cum3916.713916.711.42FalseNoneNoneFalseNoneFalse5561.72820
245228474121NonePWD SR VOL II year 2023-24. I. No. 5.1.1 P.No.9Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand)Cum5891.555891.557.38FalseNoneNoneFalseNoneFalse43479.6390
245228574121NonePWD SR VOL II year 2023-24. I. No. 5.2 P.No.9Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6948.96948.98.1FalseNoneNoneFalseNoneFalse56286.090
245228674121NonePWD CSR VOL I year 2023-24. I. No. 1.8 P.No.7Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.Cum472.82472.82107.99FalseNoneNoneFalseNoneFalse51059.83180
245228774121NonePWD CSR VOL I year 2023-24. I. No. 2.2.3 P.No.15Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6652.86652.812.02FalseNoneNoneFalseNoneFalse79966.6560
245228874121NonePWD CSR VOL I year 2023-24. Sl. No. 1(a) P.No.111Percentage Additionalities for Formwork, Centering & Scaffolding for isolated footings 8%Cum532.22532.2212.02FalseNoneNoneFalseNoneFalse6397.28440
245228974121NonePWD CSR VOL I year 2023-24. I. No. 2.2.3 P.No.15Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6652.86652.80.88FalseNoneNoneFalseNoneFalse5854.4640
245229074121NonePWD CSR VOL I year 2023-24. Sl. No. 9 P.No.111Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Columns / Shaft (Slip Centering) 70%Cum4656.964656.960.88FalseNoneNoneFalseNoneFalse4098.12480
245229174121NonePWD CSR VOL I year 2023-24. I. No. 2.2.3 P.No.15Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6652.86652.84.57FalseNoneNoneFalseNoneFalse30403.2960
245229274121NonePWD CSR VOL I year 2023-24. Sl. No. 2 P.No.111Percentage Additionalities for Formwork, Centering & Scaffolding for Plinth Beams of Buildings 50%Cum3326.43326.44.57FalseNoneNoneFalseNoneFalse15201.6480
245229374121NonePWD CSR VOL I year 2023-24. I. No. 2.5.2 P.No.16Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7185.157185.154.82FalseNoneNoneFalseNoneFalse34632.4230
245229474121NonePWD CSR VOL I year 2023-24. Sl. No. 9 P.No.111Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Columns / Shaft (Slip Centering) 70%Cum5029.65029.64.82FalseNoneNoneFalseNoneFalse24242.6720
245229574121NonePWD CSR VOL I year 2023-24. I. No. 2.5.2 P.No.16Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7185.157185.155.88FalseNoneNoneFalseNoneFalse42248.6820
245229674121NonePWD CSR VOL I year 2023-24. Sl. No. 14 P.No.112Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Beams, Lintels & Troughs of Aqueducts 60%Cum4311.084311.085.88FalseNoneNoneFalseNoneFalse25349.15040
245229774121NonePWD CSR VOL I year 2023-24. I. No. 2.5.2 P.No.16Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7185.157185.1517.91FalseNoneNoneFalseNoneFalse128686.03650
245229874121NonePWD CSR VOL I year 2023-24. Sl. No. 15 P.No.112Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Roof Slabs 50%Cum3592.573592.5717.91FalseNoneNoneFalseNoneFalse64342.92870
245229974121NonePWD CSR VOL I year 2023-24. I. No. 2.5.2 P.No.16Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7185.157185.150.43FalseNoneNoneFalseNoneFalse3089.61450
245230074121NonePWD CSR VOL I year 2023-24. Sl. No. 19 P.No.112Percentage Additionalities for Formwork, Centering & Scaffolding for Chejjas, Canopy & Other Architectural projections of minor sections 45%Cum3233.313233.310.43FalseNoneNoneFalseNoneFalse1390.32330
245230174121NonePWD CSR VOL II year 2023-24. I. No. 6.32 P.No.17Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1375.51375.5134.23FalseNoneNoneFalseNoneFalse184633.3650
245230274121NonePWD CSR VOL II year 2023-24. I. No. 8.1.2 P.No.41Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm253.05253.05156.3FalseNoneNoneFalseNoneFalse39551.7150
245230374121NonePWD SR VOL II year 2023-24. I. No. 8.8 P.No.42Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm389.55389.55178.83FalseNoneNoneFalseNoneFalse69663.22650
245230474121NonePWD SR VOL II year 2023-24. I. No. 8.22 P.No.44Providing lime wash on walls with one coat with lime of approved quality to give an even shade, including cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm10.510.5259.08FalseNoneNoneFalseNoneFalse2720.340
245230574121NonePWD SR VOL II year 2023-24.I. No. 12.13.1 P.No.100Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Cum103755.75103755.750.33FalseNoneNoneFalseNoneFalse34239.39750
245230674121NonePWD CSR VOLI year 2023-24. I. No. 12.57.6 P.No.105Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per specification. 35 mm thick both side commercialSqm3488.13488.110.08FalseNoneNoneFalseNoneFalse35160.0480
245230774121NonePWD SR VOL II year 2023-24. I. No. 12.51 P.No.104Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.Nos1066.81066.84.0FalseNoneNoneFalseNoneFalse4267.20
245230874121NonePWD SR VOL II year 2023-24. I. No. 12.90 P.No.110Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm7070.77070.710.08FalseNoneNoneFalseNoneFalse71272.6560
245230974121NonePWD SR VOL II year 2023-24. I. No. 11.34B P.No.86Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc.Kg192.15192.15211.68FalseNoneNoneFalseNoneFalse40674.3120
245231074121NonePWD SR VOL II year 2023-24. I. No. 9.17.2 P.No.61Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mmSqm1233.751233.7577.44FalseNoneNoneFalseNoneFalse95541.60
245231174121NonePWD SR VOL II year 2023-24. I. No. 9.30 P.No.64Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.Sqm5594.45594.450.38FalseNoneNoneFalseNoneFalse281845.8720
245231274121NonePWD SR VOL II year 2023-24. I. No. 10.2 P.No.69Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge.m344.4344.415.0FalseNoneNoneFalseNoneFalse5166.00
245231374121NonePWD SR VOL II year 2023-24. I. No. 8.33.3 P.No.47Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm145.95145.9526.06FalseNoneNoneFalseNoneFalse3803.4570
245231474121NonePWD SR VOL II year 2023-24. I. No. 11.26.1 P.No.84Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineerin- Charge.Kg144.9144.9335.66FalseNoneNoneFalseNoneFalse48637.1340
245231574121NonePWD SR VOL II year 2023-24. I. No. 8.33.1 P.No.46Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm165.9165.9156.3FalseNoneNoneFalseNoneFalse25930.170
245231674121NonePWD SR VOL II year 2023-24. I. No. 8.33.1 P.No.46Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm165.9165.9102.78FalseNoneNoneFalseNoneFalse17051.2020
245231774121NonePWD SR VOL II year 2023-24. I. No. 8.30 P.No.46Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including riming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm182.7182.7178.87FalseNoneNoneFalseNoneFalse32679.5490
245231874121NonePWD CSR VOL II year 2023-24. I. No. 8.84 P.No.55Providing wall black boards in 12mm thick with CM 1:3 and applied with primer & two coats of acrylic emulsion black paint including finishing etc.,complete.Sqm498.75498.7514.4FalseNoneNoneFalseNoneFalse7182.00
245231974121NonePWD CSR VOL II year 2023-24. I. No. 8.19.1 P.No.44Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge.Sqm267.75267.7522.68FalseNoneNoneFalseNoneFalse6072.570
245232074121NonePWD CSR VOL I year 2023-24. I. No. 2.11.a P.No.18Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a.BuildingsKg93929.8593929.854.67FalseNoneNoneFalseNoneFalse438652.39950
245232174121NonePWD CSR VOL II year 2023-24. I. No. 8.49 P.No.49Lettering with black Japan paint of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.cm4.24.23000.0FalseNoneNoneFalseNoneFalse12600.00
17072013040001NoneNoneBuildingsELECTRIFICATION WORKS94176.6
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
245232274122NonePWD Electrical SR 2023-24,Page No-02, It No- 1.2.1Supplying heavy gauge PVC conduit pipe 19/20mm dia 2mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessarym69.369.3200.0FalseNoneNoneFalseNoneFalse13860.00
245232374122NonePWD Electrical SR 2023-24,Page No-02, It No- 1.3.1Supplying heavy gauge PVC Conduit Pipe 19/20mm dia 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.m71.471.480.0FalseNoneNoneFalseNoneFalse5712.00
245232474122NonePWD Electrical SR 2023-24,Page No-05, It No- 2.2.1Point wiring using Copper wire without switch.Supplying and wiring adopting loop system in existing PVC Conduit/casing capping casing capping using 2x1.5Sqmm (Phase&Neutral) &1x1.0sqmm(Earthwire) FRLSmultistrand PVC insulated copperwire (confirming to IS-694:and latest amendments) without control switch shall be fixed on the existing plastic sheet/gangbox, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.. Short point upto 3Mtr from tapping point to out let via switch boxPoint282.45282.4512.0FalseNoneNoneFalseNoneFalse3389.40
245232574122NonePWD Electrical SR 2023-24,Page No-05, It No- 2.2.2Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch boxPoint397.95397.9514.0FalseNoneNoneFalseNoneFalse5571.30
245232674122NonePWD Electrical SR 2023-24,Page No-05, It No- 2.2.3Long point above 6Mtr upto 10Mtr from tapping point to out let via switch boxPoint582.75582.7510.0FalseNoneNoneFalseNoneFalse5827.50
245232774122NonePWD Electrical SR 2023-24,Page No-05, It No- 2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 1.5sqmm.m27.0227.02300.0FalseNoneNoneFalseNoneFalse8106.00
245232874122NonePWD Electrical SR 2023-24,Page No-05, It No- 2.3.32.5sqmm.m44.144.1350.0FalseNoneNoneFalseNoneFalse15435.00
245232974122NonePWD Electrical SR 2023-24,Page No-10,It No- 3.14.7Supplying And fixing/replacing of 6/16/32A electricalaccessories on existing switch board.6A Batten HolderNo77.777.712.0FalseNoneNoneFalseNoneFalse932.40
245233074122NonePWD Electrical SR 2023-24, Page No-8, It No- 3.1.1Supplying 6A flush type socket and 6 amps flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 - 6Amps 2 WayEach134.4134.420.0FalseNoneNoneFalseNoneFalse2688.00
245233174122NonePWD Electrical SR 2023-24, Page No-9, It No- 3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 Stepped fan regulator. Two ModuleEach374.85374.854.0FalseNoneNoneFalseNoneFalse1499.40
245233274122NonePWD Electrical SR 2023-24, Page No-9, It No- 3.6.716Amps one way switch.Each189.0189.08.0FalseNoneNoneFalseNoneFalse1512.00
245233374122NonePWD Electrical SR 2023-24, Page No-8, It No- 3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall . 4-5WayEach185.85185.854.0FalseNoneNoneFalseNoneFalse743.40
245233474122NonePWD Electrical SR 2023-24, Page No-8, It No- 3.4.58WayEach274.05274.054.0FalseNoneNoneFalseNoneFalse1096.20
245233574122NonePWD Electrical SR 2023-24, Page No-8, It No- 3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. - 4 ModuleEach183.75183.754.0FalseNoneNoneFalseNoneFalse735.00
245233674122NonePWD Electrical SR 2023-24, Page No-8, It No- 3.5.58ModuleEach298.2298.24.0FalseNoneNoneFalseNoneFalse1192.80
245233774122NonePWD Electrical SR 2023-24,Page No-47,It No-11.13.2Supplying and fixing of slim patty fitting, made out of CRCA Sheet metal body with locking type holder completely wired. Excluding Ballast & Fluorescent Tube. 1 x 4' Tube light fitting.Each282.45282.4512.0FalseNoneNoneFalseNoneFalse3389.40
245233874122NonePWD Electrical SR 2023-24Page No-48, It No-12.12.1Supplying and fixing/replacing of fluorescent tube. 18 to 40WEach99.7599.7512.0FalseNoneNoneFalseNoneFalse1197.00
245233974122NonePWD Electrical SR 2023-24,Page No-30, It No- 6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts,50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200 mm) Regular modelEach3133.23133.24.0FalseNoneNoneFalseNoneFalse12532.80
245234074122NonePWD Electrical SR 2023-24,Page No-57, It No- 13.10Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. Ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.Each179.55179.554.0FalseNoneNoneFalseNoneFalse718.20
245234174122NonePWD Electrical SR 2023-24,Page No-17,It No- 5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32Amps SPEach435.75435.758.0FalseNoneNoneFalseNoneFalse3486.00
245234274122NonePWD Electrical SR 2023-24,Page No-17,It No- 5.18.46-32 Amps DPEach775.95775.954.0FalseNoneNoneFalseNoneFalse3103.80
245234374122NonePWD Electrical SR 2023-24, Page No-19, It No- 5.30Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 20A single phase Class-1 Accuracy with Temper Proof Energy Meter.Each1449.01449.01.0FalseNoneNoneFalseNoneFalse1449.00
17072028180000NoneNoneBuildingsConstruction of Two Additional Room for Govt Higher Primary School at Rampur Village in Lingasugur Town of Raichur District Under KKRDB for the Year 2022-23 RCH231923341 GEN2351887.17
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
245270474147NonePWD Electrical SR 2023-24,Page No-02, It No- 1.2.1Supplying heavy gauge PVC conduit pipe 19/20mm dia 2mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessarym69.369.3200.0FalseNoneNoneFalseNoneFalse13860.00
245265974147NonePWD CSR VOL I year 2023-24.I. No.1.12 P.No.08Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.Cum99.7599.7545.0FalseNoneNoneFalseNoneFalse4488.750
245266074147NonePWD CSR VOL I year 2023-24. I. No.1.14.1 P.No.08Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the workCum107.1107.156.97FalseNoneNoneFalseNoneFalse6101.4870
245270574147NonePWD Electrical SR 2023-24,Page No-02, It No- 1.3.1Supplying heavy gauge PVC Conduit Pipe 19/20mm dia 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.m71.471.480.0FalseNoneNoneFalseNoneFalse5712.00
245270674147NonePWD Electrical SR 2023-24,Page No-05, It No- 2.2.1Point wiring using Copper wire without switch.Supplying and wiring adopting loop system in existing PVC Conduit/casing capping casing capping using 2x1.5Sqmm (Phase&Neutral) &1x1.0sqmm(Earthwire) FRLSmultistrand PVC insulated copperwire (confirming to IS-694:and latest amendments) without control switch shall be fixed on the existing plastic sheet/gangbox, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.. Short point upto 3Mtr from tapping point to out let via switch boxPoint282.45282.4512.0FalseNoneNoneFalseNoneFalse3389.40
245266174147NonePWD CSR VOL I year 2023-24. I. No. 1.4.1 P.No.05Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 mCum254.1254.116.59FalseNoneNoneFalseNoneFalse4215.5190
245266274147NonePWD CSR VOL I year 2023-24.I.No.1.23 P.No.11Providing and Filling in foundation with granite / trap broken metal 100mm. And down size & with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift complete as per specifications.Cum2816.12816.112.66FalseNoneNoneFalseNoneFalse35651.8260
245270774147NonePWD Electrical SR 2023-24,Page No-05, It No- 2.2.2Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch boxPoint397.95397.9514.0FalseNoneNoneFalseNoneFalse5571.30
245270874147NonePWD Electrical SR 2023-24,Page No-05, It No- 2.2.3Long point above 6Mtr upto 10Mtr from tapping point to out let via switch boxPoint582.75582.7510.0FalseNoneNoneFalseNoneFalse5827.50
245266374147NonePWD CSR VOL I year 2023-24. I. No. 2.1.3 P.No.15Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum6288.456288.4518.82FalseNoneNoneFalseNoneFalse118348.6290
245270974147NonePWD Electrical SR 2023-24,Page No-05, It No- 2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 1.5sqmm.m27.0227.02300.0FalseNoneNoneFalseNoneFalse8106.00
245266474147NonePWD CSR VOL I year 2023-24. I. No. 2.1.4 P.No.15Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregatesCum6527.856527.851.42FalseNoneNoneFalseNoneFalse9269.5470
245271074147NonePWD Electrical SR 2023-24,Page No-05, It No- 2.3.32.5sqmm.m44.144.1350.0FalseNoneNoneFalseNoneFalse15435.00
245266574147NonePWD CSR VOL I year 2023-24. Sl. No. 14 P.No.112Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Beams, Lintels & Troughs of Aqueducts 60%Cum3916.713916.711.42FalseNoneNoneFalseNoneFalse5561.72820
245266674147NonePWD SR VOL II year 2023-24. I. No. 5.1.1 P.No.9Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand)Cum5891.555891.557.38FalseNoneNoneFalseNoneFalse43479.6390
245271174147NonePWD Electrical SR 2023-24,Page No-10,It No- 3.14.7Supplying And fixing/replacing of 6/16/32A electricalaccessories on existing switch board.6A Batten HolderNo77.777.712.0FalseNoneNoneFalseNoneFalse932.40
245271274147NonePWD Electrical SR 2023-24, Page No-8, It No- 3.1.1Supplying 6A flush type socket and 6 amps flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 - 6Amps 2 WayEach134.4134.420.0FalseNoneNoneFalseNoneFalse2688.00
245266774147NonePWD SR VOL II year 2023-24. I. No. 5.2 P.No.9Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6948.96948.98.1FalseNoneNoneFalseNoneFalse56286.090
245266874147NonePWD CSR VOL I year 2023-24. I. No. 1.8 P.No.7Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.Cum472.82472.82107.99FalseNoneNoneFalseNoneFalse51059.83180
245271374147NonePWD Electrical SR 2023-24, Page No-9, It No- 3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 Stepped fan regulator. Two ModuleEach374.85374.854.0FalseNoneNoneFalseNoneFalse1499.40
245271474147NonePWD Electrical SR 2023-24, Page No-9, It No- 3.6.716Amps one way switch.Each189.0189.08.0FalseNoneNoneFalseNoneFalse1512.00
245266974147NonePWD CSR VOL I year 2023-24. I. No. 2.2.3 P.No.15Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6652.86652.812.02FalseNoneNoneFalseNoneFalse79966.6560
245267074147NonePWD CSR VOL I year 2023-24. Sl. No. 1(a) P.No.111Percentage Additionalities for Formwork, Centering & Scaffolding for isolated footings 8%Cum532.22532.2212.02FalseNoneNoneFalseNoneFalse6397.28440
245271574147NonePWD Electrical SR 2023-24, Page No-8, It No- 3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall . 4-5WayEach185.85185.854.0FalseNoneNoneFalseNoneFalse743.40
245267174147NonePWD CSR VOL I year 2023-24. I. No. 2.2.3 P.No.15Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6652.86652.80.88FalseNoneNoneFalseNoneFalse5854.4640
245271674147NonePWD Electrical SR 2023-24, Page No-8, It No- 3.4.58WayEach274.05274.054.0FalseNoneNoneFalseNoneFalse1096.20
245271774147NonePWD Electrical SR 2023-24, Page No-8, It No- 3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. - 4 ModuleEach183.75183.754.0FalseNoneNoneFalseNoneFalse735.00
245267274147NonePWD CSR VOL I year 2023-24. Sl. No. 9 P.No.111Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Columns / Shaft (Slip Centering) 70%Cum4656.964656.960.88FalseNoneNoneFalseNoneFalse4098.12480
245267374147NonePWD CSR VOL I year 2023-24. I. No. 2.2.3 P.No.15Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6652.86652.84.57FalseNoneNoneFalseNoneFalse30403.2960
245271874147NonePWD Electrical SR 2023-24, Page No-8, It No- 3.5.58ModuleEach298.2298.24.0FalseNoneNoneFalseNoneFalse1192.80
245271974147NonePWD Electrical SR 2023-24,Page No-47,It No-11.13.2Supplying and fixing of slim patty fitting, made out of CRCA Sheet metal body with locking type holder completely wired. Excluding Ballast & Fluorescent Tube. 1 x 4' Tube light fitting.Each282.45282.4512.0FalseNoneNoneFalseNoneFalse3389.40
245267474147NonePWD CSR VOL I year 2023-24. Sl. No. 2 P.No.111Percentage Additionalities for Formwork, Centering & Scaffolding for Plinth Beams of Buildings 50%Cum3326.43326.44.57FalseNoneNoneFalseNoneFalse15201.6480
245272074147NonePWD Electrical SR 2023-24Page No-48, It No-12.12.1Supplying and fixing/replacing of fluorescent tube. 18 to 40WEach99.7599.7512.0FalseNoneNoneFalseNoneFalse1197.00
245267574147NonePWD CSR VOL I year 2023-24. I. No. 2.5.2 P.No.16Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7185.157185.154.82FalseNoneNoneFalseNoneFalse34632.4230
245272174147NonePWD Electrical SR 2023-24,Page No-30, It No- 6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts,50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200 mm) Regular modelEach3133.23133.24.0FalseNoneNoneFalseNoneFalse12532.80
245267674147NonePWD CSR VOL I year 2023-24. Sl. No. 9 P.No.111Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Columns / Shaft (Slip Centering) 70%Cum5029.65029.64.82FalseNoneNoneFalseNoneFalse24242.6720
245272274147NonePWD Electrical SR 2023-24,Page No-57, It No- 13.10Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. Ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.Each179.55179.554.0FalseNoneNoneFalseNoneFalse718.20
245267774147NonePWD CSR VOL I year 2023-24. I. No. 2.5.2 P.No.16Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7185.157185.155.88FalseNoneNoneFalseNoneFalse42248.6820
245272374147NonePWD Electrical SR 2023-24,Page No-17,It No- 5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32Amps SPEach435.75435.758.0FalseNoneNoneFalseNoneFalse3486.00
245267874147NonePWD CSR VOL I year 2023-24. Sl. No. 14 P.No.112Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Beams, Lintels & Troughs of Aqueducts 60%Cum4311.084311.085.88FalseNoneNoneFalseNoneFalse25349.15040
245272474147NonePWD Electrical SR 2023-24,Page No-17,It No- 5.18.46-32 Amps DPEach775.95775.954.0FalseNoneNoneFalseNoneFalse3103.80
245267974147NonePWD CSR VOL I year 2023-24. I. No. 2.5.2 P.No.16Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7185.157185.1517.91FalseNoneNoneFalseNoneFalse128686.03650
245268074147NonePWD CSR VOL I year 2023-24. Sl. No. 15 P.No.112Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Roof Slabs 50%Cum3592.573592.5717.91FalseNoneNoneFalseNoneFalse64342.92870
245272574147NonePWD Electrical SR 2023-24, Page No-19, It No- 5.30Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 20A single phase Class-1 Accuracy with Temper Proof Energy Meter.Each1449.01449.01.0FalseNoneNoneFalseNoneFalse1449.00
245268174147NonePWD CSR VOL I year 2023-24. I. No. 2.5.2 P.No.16Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7185.157185.150.43FalseNoneNoneFalseNoneFalse3089.61450
245268274147NonePWD CSR VOL I year 2023-24. Sl. No. 19 P.No.112Percentage Additionalities for Formwork, Centering & Scaffolding for Chejjas, Canopy & Other Architectural projections of minor sections 45%Cum3233.313233.310.43FalseNoneNoneFalseNoneFalse1390.32330
245268374147NonePWD CSR VOL II year 2023-24. I. No. 6.32 P.No.17Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1375.51375.5134.23FalseNoneNoneFalseNoneFalse184633.3650
245268474147NonePWD CSR VOL II year 2023-24. I. No. 8.1.2 P.No.41Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm253.05253.05156.3FalseNoneNoneFalseNoneFalse39551.7150
245268574147NonePWD SR VOL II year 2023-24. I. No. 8.8 P.No.42Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm389.55389.55178.83FalseNoneNoneFalseNoneFalse69663.22650
245268674147NonePWD SR VOL II year 2023-24. I. No. 8.22 P.No.44Providing lime wash on walls with one coat with lime of approved quality to give an even shade, including cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm10.510.5259.08FalseNoneNoneFalseNoneFalse2720.340
245268774147NonePWD SR VOL II year 2023-24.I. No. 12.13.1 P.No.100Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Cum103755.75103755.750.33FalseNoneNoneFalseNoneFalse34239.39750
245268874147NonePWD CSR VOLI year 2023-24. I. No. 12.57.6 P.No.105Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per specification. 35 mm thick both side commercialSqm3488.13488.110.08FalseNoneNoneFalseNoneFalse35160.0480
245268974147NonePWD SR VOL II year 2023-24. I. No. 12.51 P.No.104Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.Nos1066.81066.84.0FalseNoneNoneFalseNoneFalse4267.20
245269074147NonePWD SR VOL II year 2023-24. I. No. 12.90 P.No.110Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm7070.77070.710.08FalseNoneNoneFalseNoneFalse71272.6560
245269174147NonePWD SR VOL II year 2023-24. I. No. 11.34B P.No.86Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc.Kg192.15192.15211.68FalseNoneNoneFalseNoneFalse40674.3120
245269274147NonePWD SR VOL II year 2023-24. I. No. 9.17.2 P.No.61Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mmSqm1233.751233.7577.44FalseNoneNoneFalseNoneFalse95541.60
245269374147NonePWD SR VOL II year 2023-24. I. No. 9.30 P.No.64Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.Sqm5594.45594.450.38FalseNoneNoneFalseNoneFalse281845.8720
245269474147NonePWD SR VOL II year 2023-24. I. No. 10.2 P.No.69Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge.m344.4344.415.0FalseNoneNoneFalseNoneFalse5166.00
245269574147NonePWD SR VOL II year 2023-24. I. No. 8.33.3 P.No.47Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm145.95145.9526.06FalseNoneNoneFalseNoneFalse3803.4570
245269674147NonePWD SR VOL II year 2023-24. I. No. 11.26.1 P.No.84Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineerin- Charge.Kg144.9144.9335.66FalseNoneNoneFalseNoneFalse48637.1340
245269774147NonePWD SR VOL II year 2023-24. I. No. 8.33.1 P.No.46Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm165.9165.9156.3FalseNoneNoneFalseNoneFalse25930.170
245269874147NonePWD SR VOL II year 2023-24. I. No. 8.33.1 P.No.46Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm165.9165.9102.78FalseNoneNoneFalseNoneFalse17051.2020
245269974147NonePWD SR VOL II year 2023-24. I. No. 8.30 P.No.46Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including riming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm182.7182.7178.87FalseNoneNoneFalseNoneFalse32679.5490
245270074147NonePWD CSR VOL II year 2023-24. I. No. 8.84 P.No.55Providing wall black boards in 12mm thick with CM 1:3 and applied with primer & two coats of acrylic emulsion black paint including finishing etc.,complete.Sqm498.75498.7514.4FalseNoneNoneFalseNoneFalse7182.00
245270174147NonePWD CSR VOL II year 2023-24. I. No. 8.19.1 P.No.44Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge.Sqm267.75267.7522.68FalseNoneNoneFalseNoneFalse6072.570
245270274147NonePWD CSR VOL I year 2023-24. I. No. 2.11.a P.No.18Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a.BuildingsKg93929.8593929.854.67FalseNoneNoneFalseNoneFalse438652.39950
245270374147NonePWD CSR VOL II year 2023-24. I. No. 8.49 P.No.49Lettering with black Japan paint of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.cm4.24.23000.0FalseNoneNoneFalseNoneFalse12600.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17072013050000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17072013050000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17072013050001NoneNoneELIGIBILITYThe bidder is required to ensure browser compatibility of the computer well in advance to the last date and time for receipt of tenders. The departments shall not be responsible for non-accessibility of kppp portal due to internet connectivity issues and technical glitches at bidders end.None
17072021550000NoneNoneELIGIBILITYAs per Karnataka State Government order No.LD/300/LET/2006 Bangalore Dated 01.01.2007 and Government Letter No.PW/134/BMS/2007 Dated 27.7.2007, a sum amounting to 1%of the bill amount will be deducted towards Construction Labour Welfare fund.None
17072021670000NoneNoneELIGIBILITYThe Item Rate quoted shall include the Royalty Charges on construction materials and other taxes as per prevailing Government Orders.None
17072022410000NoneNoneELIGIBILITYConditional tenders will not be accepted.None
17072022620000NoneNoneELIGIBILITYThe Tenderer shall obtain the workdone certificate in the prescribed format from the Competent Authority not below the rank of Executive Engineer (District Level Officer) and scan the Original Certificate and attach the scanned file to the Bid. The Original Certificate/Certificates shall be produced at the time of opening of technical Bids for physical verification.None
17072022760000NoneNoneELIGIBILITYThe Employer reserves the right to Reject any or all Tenders without assigning any reason.None
17072023120000NoneNoneELIGIBILITYTenderer shall note that the Tenders of those found Eligible as mentioned in Clause 3 - Qualification of the Tenderer in Section 2 : Instructions to Tenderers (ITT), will only be considered for evaluation.None
17072023190000NoneNoneELIGIBILITYBidders are advised to note that, 18% GST will be added to the contract amount.None
17072023330000NoneNoneELIGIBILITYThe Increse in GST shall not be paid in the extended period of contract for which the contractor alone is responsible for delay as determined by the authority while granting the extension of time.None
17072023570000NoneNoneELIGIBILITYThe bidder should mention the UDIN No on the turnover certificate, failing which bid is rejectedNone
17072023740000NoneNoneELIGIBILITYIf the bidder uploaded the false document while participating in the tender, the bidder will be responsible and action will be initiated as per the tender clause.None
17072024030000NoneNoneELIGIBILITYThe work should be completed in 06 (Six) Months ( including monsoon)None
17072024210000NoneNoneELIGIBILITYThe KPWD Code, KTTP Act/Rules ,Delegation of Powers and other Government Orders issued by the Government from time to time will apply.None
17072024890000NoneNoneELIGIBILITYAll the specifications in the commercial bid format please be read as with all leads and lifts etc., complete as per specification and as directed by the engineer-in-charge.None
17072025530000NoneNoneELIGIBILITYThe Bidder will be qualified only if their available tender capacity is more than the total tender value of this work.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneProposals for subcontracting components of works amounting to more than 20% of the contract price (for each, the qualifications and experience of the identified sub-contractor in the relevant fields should be attached)NoneNone
NoneNoneNoneNone3.2) To qualify for award of this contract, each tenderer in its name should have in the last five years i.e. 2018-19 to 2022-23) (b) Mandating satisfactory completion as a prime contractor for at least one similar work to an extent of 50% of the cost of the work i.e., Rs: 11.76 Lakhs.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneTo qualify for award of this contract, each tenderer in its name should have in the last five years i.e. 2018-19 to 2022-23) (a) achieved in at least Two financial years and average financial turnover (in all classes of civil engineering construction works only) not less than the estimated annual payments under this contract i.e., 23.52 LakhsFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneITR Filed Copy (Mentioning PAN)
NoneNoneNoneNoneBanker Details for referenceFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Banker Details for reference
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditors reports for the last five yearsFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneITR Filed Copy (Mentioning PAN)
NoneNoneNoneNoneList of existing commitments and ongoing worksOthersexisting commitments and ongoing works
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- existing commitments and ongoing works
NoneNoneNoneNoneList of works for which tenders already submittedOthersList of works for which tenders already submitted
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- List of works for which tenders already submitted
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
PWD Registration CertificateTrueTechnical Bid
Similar nature of single work done certificateTrueTechnical Bid
Existing commitments or Ongoing worksTrueTechnical Bid
Any other relevant documentsTrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone