| 2448851 | 73862 | None | code01 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m | Cum | 114.24 | 114.24 | 3.53 | False | None | None | False | None | False | 403.2672 | 0 |
| 2448852 | 73862 | None | code02 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to coplete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6707.68 | 6707.68 | 0.59 | False | None | None | False | None | False | 3957.5312 | 0 |
| 2448853 | 73862 | None | code03 | Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification I.S. 3620/1979 having compressive strength not less than 3.5 N/mm2 for saturated dry samples - For Foundation in CM 1:6. | Cum | 7138.88 | 7138.88 | 2.75 | False | None | None | False | None | False | 19631.92 | 0 |
| 2448854 | 73862 | None | code04 | Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification I.S. 3620/1979 having compressive strength not less than 3.5 N/mm2 for saturated dry samples - For Basement in CM 1:6. | Cum | 7221.76 | 7221.76 | 2.75 | False | None | None | False | None | False | 19859.84 | 0 |
| 2448855 | 73862 | None | code05 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 297.92 | 297.92 | 14.85 | False | None | None | False | None | False | 4424.112 | 0 |
| 2448856 | 73862 | None | code06 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to coplete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6963.04 | 6963.04 | 2.1 | False | None | None | False | None | False | 14622.384 | 0 |
| 2448857 | 73862 | None | code07 | Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification I.S. 3620/1979 having compressive strength not less than 3.5 N/mm2 for saturated dry samples - For Super structure in CM 1:6. | Cum | 7565.6 | 7565.6 | 11.4599 | False | None | None | False | None | False | 86701.01944 | 0 |
| 2448858 | 73862 | None | code08 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant ISCodes machine mixed with super plasticisers, laidin layers, well compacted using needle vibrators, providing weep holes wherever necesary, includingall lead & lifts, cost of all materials of quality,confirming to the requirements of relevant IS codes,labour, Usage charges of machinery, curing and allother ppurtenances required to complete the workas per echnical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal sizegraded crushed coarse aggregates | Cum | 10622.64 | 10622.64 | 0.38 | False | None | None | False | None | False | 4036.6032 | 0 |
| 2448859 | 73862 | None | code09 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant ISCodes machine mixed with super plasticisers, laidin layers, well compacted using needle vibrators, providing weep holes wherever necesary, includingall lead & lifts, cost of all materials of quality,confirming to the requirements of relevant IS codes,labour, Usage charges of machinery, curing and allother ppurtenances required to complete the workas per echnical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal sizegraded crushed coarse aggregates | Cum | 11330.81 | 11330.81 | 0.23 | False | None | None | False | None | False | 2606.0863 | 0 |
| 2448860 | 73862 | None | code10 | Steel Fabrication Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification | Tonne | 100191.84 | 100191.84 | 0.0533 | False | None | None | False | None | False | 5340.225072 | 0 |
| 2448861 | 73862 | None | code11 | Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. | Sqm | 1848.0 | 1848.0 | 1.5 | False | None | None | False | None | False | 2772.0 | 0 |
| 2448862 | 73862 | None | code12 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerin- charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. | Sqm | 636.16 | 636.16 | 56.0 | False | None | None | False | None | False | 35624.96 | 0 |
| 2448863 | 73862 | None | code13 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 164.64 | 164.64 | 364.0 | False | None | None | False | None | False | 59928.96 | 0 |
| 2448864 | 73862 | None | code14 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :Ridges plain (500 - 600mm) | m | 505.12 | 505.12 | 7.0 | False | None | None | False | None | False | 3535.84 | 0 |
| 2448865 | 73862 | None | code15 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materi als, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 269.92 | 269.92 | 58.62 | False | None | None | False | None | False | 15822.7104 | 0 |
| 2448866 | 73862 | None | code16 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Out side) | Sqm | 415.52 | 415.52 | 54.12 | False | None | None | False | None | False | 22487.9424 | 0 |
| 2448867 | 73862 | None | code17 | Finishing with Deluxe Multi surface paint system for interiors and exte riors using Primer as per manufacturers specifications: Two coats ap plied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 176.96 | 176.96 | 58.62 | False | None | None | False | None | False | 10373.3952 | 0 |
| 2448868 | 73862 | None | code18 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paer smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 194.88 | 194.88 | 54.12 | False | None | None | False | None | False | 10546.9056 | 0 |
| 2448869 | 73862 | None | code19 | Providing and laying Cement concrete flooring 40 mm thick with 20 mm nominal size stone aggregate using 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry complete | Sqm | 505.12 | 505.12 | 33.0 | False | None | None | False | None | False | 16668.96 | 0 |
| 2448870 | 73862 | None | code20 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding | Kg | 188.16 | 188.16 | 43.1999 | False | None | None | False | None | False | 8128.493184 | 0 |
| 2448871 | 73862 | None | code21 | Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having a overall size of 60mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm X 58mm with GI reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2-2.5 mm. Maximum possible size 1819mm x 1819mm (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made | Sqm | 6036.8 | 6036.8 | 2.88 | False | None | None | False | None | False | 17385.984 | 0 |
| 2448872 | 73862 | None | code22 | Providing and fixing factory made pre fabricated non-monolithic Premium R.C.C. Door Frames factory manufactured in separate parts and assembled at bolts nuts system with mechanical table vibrating as per IS 6523-1983 with using M25 concrete as per IS 456 and reinforced with 1.70 kg of TMT steel reinforced with 3 No. of 6 mm dia Main TMT bars and 6 mm Dia TMT stirrups welded at 40 cm c/c in triangle shape per meter length of door frames, including cost of steel and fabrication charges having 4 No. of 304 Grade Stainless Steel hinges plate attachment made of 165 mm x 25 mm x 2.5 mm Stainless Steel Flat welded with required iron rods and flats with drilling for fixing flat CSK Head Machine screws made out of 304 grade stainless steel screws and MS square nuts of size 8 x 8 square and length 10 mm and making necessary provision in concrete for fixing aldrops, tower bolts and hold fasts etc., complete including two coats of oil based enamel primer providing without cill for shutter thickness upto 32 mm, 21 days tank immersed curing including cost of labour, materials, usage charge of machinery complete excluding the cost of door fixtures as per the direction of Engineer. Cross section of 60 mm x 100 mm | m | 963.2 | 963.2 | 4.2 | False | None | None | False | None | False | 4045.44 | 0 |
| 2448873 | 73862 | None | code23 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 30 mm thick both side commercial | Sqm | 3365.6 | 3365.6 | 4.1 | False | None | None | False | None | False | 13798.96 | 0 |
| 2448874 | 73862 | None | code24 | Concealed Conduit System: Supplying 19/20 mm dia 2mm thick heavy gauge PVC conduit pipe with suitable size bends, metal / PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary etc., including cost and conveyance of all materials, labour, HOM of equipments, all lead and lift and all other incidental charges etc., complete as per standard technical specifications and as directed by the Engineer-in-charge of the work. | m | 66.0 | 66.0 | 18.5 | False | None | None | False | None | False | 1221.0 | 0 |
| 2448875 | 73862 | None | code25 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12 mm thick wood, after due groove cutting, finishing with necessary cement plastering complete.10" x 7" x 3" (254 x 178 x 76 mm) | Each | 112.0 | 112.0 | 2.0 | False | None | None | False | None | False | 224.0 | 0 |
| 2448876 | 73862 | None | code26 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3m from tapping point to out let via switch box | Each | 269.0 | 269.0 | 2.0 | False | None | None | False | None | False | 538.0 | 0 |
| 2448877 | 73862 | None | code27 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch box | Each | 379.0 | 379.0 | 2.0 | False | None | None | False | None | False | 758.0 | 0 |
| 2448878 | 73862 | None | code28 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:confirming to latest amendments. 1.5 mm2 | m | 26.0 | 26.0 | 50.0 | False | None | None | False | None | False | 1300.0 | 0 |
| 2448879 | 73862 | None | code29 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:confirming to latest amendments. 2.5 mm2 | m | 42.0 | 42.0 | 25.0 | False | None | None | False | None | False | 1050.0 | 0 |
| 2448880 | 73862 | None | code30 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module | Each | 344.0 | 344.0 | 1.0 | False | None | None | False | None | False | 344.0 | 0 |
| 2448881 | 73862 | None | code31 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A One Way Switch | Each | 102.0 | 102.0 | 6.0 | False | None | None | False | None | False | 612.0 | 0 |
| 2448882 | 73862 | None | code32 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. I - Single Door 4 Way SP & N | Each | 1214.0 | 1214.0 | 1.0 | False | None | None | False | None | False | 1214.0 | 0 |
| 2448883 | 73862 | None | code33 | Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA. On wall/ ceiling / Rafter / Girders | Each | 122.0 | 122.0 | 4.0 | False | None | None | False | None | False | 488.0 | 0 |