createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1707305699868
version3
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeEXCLUSIVE_TAX
tenderFee7500.00
emd1040000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose20-02-2024 14:00:00
tenderQueryClose12-02-2024 17:00:00
technicalBidOpen21-02-2024 16:00:00
publishedDate07-02-2024 17:26:55
publishedByPostBWSSB_CE_PROJECT_BNG
publishedByUserKPE11769 - RAJIV K N
bidValidityPeriod90
noOfCalls1
preBidMeetingDate12-02-2024 14:30:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonVenugopal Executive Engineer
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber9591987965
tenderSupplierListNone
tenderSchedule
createdTs1707305699895
version5
createdDateNone
modifiedDateNone
tenderNumberBWSSB/2023-24/CT/WORK_INDENT322
titleThe work of construction of Construction of 13.5 ML GLR at Kalkere with pumping station at Rammurthy Nagar
descriptionThe work of construction of Construction of 13.5 ML GLR at Kalkere with pumping station at Rammurthy Nagar
categoryWORKS
categoryTextWorks
ecv104678769.11
deptNameBengaluru Water Supply And Sewerage Board
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location5137
locationNameBWSSB Chief Engineer Project Bengaluru
provisionalAmount137800000.0
groupOverheadTotalNone
fileNumber1702/2023-24
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17073057000001NoneNoneConstruction of new tanksThe work of construction of Construction of 13.5 ML GLR at Kalkere with pumping station at Rammurthy Nagar104678769.11
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
249845075750Nonecode01Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 mCum102.0102.08071.24FalseNoneNoneFalseNoneFalse823266.480
249845175750Nonecode02Earth work excavation for pipeline trenches by mechanical means as per drawing and technical specification, including setting out, construction of shoring, strutting, cost of blasting materials, barricading, caution lights, bracing, using sight rails & bonding rods at every 100 mm wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work and all other appurtenances to complete in the following strata. Hard rock (blasting prohibited) depth exceeding 3m but not exceeding 4.5mCum1196.01196.01614.248FalseNoneNoneFalseNoneFalse1930640.6080
249845275750Nonecode03Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum266.0266.01014.0FalseNoneNoneFalseNoneFalse269724.00
249845375750Nonecode04Disposal off the excess excavated earth of all types by vehicle including loading,unloading with all lead and lifts, labour, HOM of machineries etc.( Debries) for: 10kmCum230.88230.888671.488FalseNoneNoneFalseNoneFalse2002073.149440
249845475750Nonecode05Disposing the existing construction waste dumped at site to a suitable location within a radius of 20 KM in all types of earth by vehicle including loading,unloading with all lead and lifts, labour, HOM of machineries etc.( Debries) for: 2.0kmCum418.08418.083000.0FalseNoneNoneFalseNoneFalse1254240.00
249845575750Nonecode06Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)-Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregatesCum6217.06217.0756.276FalseNoneNoneFalseNoneFalse4701767.8920
249845675750Nonecode07Providing and laying in position cement concrete of design mix M30 with 20mm nominal size graded crushed coarse aggregates for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)Cum6499.06499.01530.24FalseNoneNoneFalseNoneFalse9945029.760
249845775750Nonecode08Formwork at3percentage for foundationsCum194.97194.971530.24FalseNoneNoneFalseNoneFalse298350.89280
249845875750Nonecode09Providing and laying in Reinforced cement concrete of design mix M30 for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)Cum6605.06605.01117.23FalseNoneNoneFalseNoneFalse7379304.150
249845975750Nonecode10Formwork at 10percentage for retaining structuresCum660.5660.51117.23FalseNoneNoneFalseNoneFalse737930.4150
249846075750Nonecode01Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (coulmns and head room)Cum6742.06742.0729.09FalseNoneNoneFalseNoneFalse4915524.780
249846175750Nonecode12Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification- building worksKg89.4589.45406787.2FalseNoneNoneFalseNoneFalse36387115.040
249846275750Nonecode13Providing and constructing precast concrete solid blocks with compressive strength not less than 35kg. per sqm with cement mortar 1:4 masonry (quoin, Jamb, closer blocks) with solid concrete blocks of size 40X20X20 cms conforming to IS.2185/ 1965 in superstructure including cost of materials, labour charges, double scaffolding, curing complete as per specifications.Sqm1310.01310.0126.6FalseNoneNoneFalseNoneFalse165846.00
249846375750Nonecode14Providing plastering to masonry including providing and removing double scaffolding rounding of all corners whenever required smooth rendering curing etc., complete as per specifications with burnt brick masonry plain plastering 20mm thick in CM 1:4 (external)Sqm354.0354.0253.2FalseNoneNoneFalseNoneFalse89632.80
249846475750Nonecode15Providing and appying integral crystalline slurry of hydropholic in nature for waterproofing treatment to RCC structures like floor and walls of reservoirs, sewage, effluent and water treatment plants, overhead tanks etc., prepared by mixing in the ratio of 5:2 (5 parts integral crystalline slurry 2 parts water) for horizontal and vertical surfaces and applying the same from negative (internal) side with the help of synthetic fibre brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i., by reducing permeability of concrete by more than 90percentage compared with control concrete as per DIN 1048 and resistant to 16 Bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self healing of cracks upto width of 0.5mm. The work shall be carried out all complete as per specification and the direction of the Engineer in charge. The product performance shall carry guarantee for 10 years against any leakage. For horizontal and vertical surfaces in two coats at 0.7kg per sqm per coat.Sqm433.0433.03391.7FalseNoneNoneFalseNoneFalse1468606.10
249846575750Nonecode16Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm127.0127.01442.0FalseNoneNoneFalseNoneFalse183134.00
249846675750Nonecode17Providing and laying in position yelahanka tiles of size 125 x 250mm of approved quality and make, over a bed of cement mortar 1:3 with thickness varying from 100mm to 25mm including weather proof course and pointed with cement mortar 1:3 mix with red oxide including curing cost of materials, labour complete as per specifications.Sqm1100.01100.02444.0FalseNoneNoneFalseNoneFalse2688400.00
249846775750Nonecode18Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/ m²) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Sqm988.0988.01.08FalseNoneNoneFalseNoneFalse1067.040
249846875750Nonecode19Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. completeNos.1114.01114.02.0FalseNoneNoneFalseNoneFalse2228.00
249846975750Nonecode20Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete including cost of materials, labour, usage charges of machinery complete as per specifications.Nos.437.0437.02.0FalseNoneNoneFalseNoneFalse874.00
249847075750Nonecode21Supplying and fixing PVC encapsulated CI rungs to shapes and at locations specified in drawings and specifications for Valve chambersNos40.040.05.0FalseNoneNoneFalseNoneFalse200.00
249847175750Nonecode22Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/m²) including cost of materials, labour, usage charges of machinery complete as per specifications.Sqm1171.01171.00.252FalseNoneNoneFalseNoneFalse295.0920
249847275750Nonecode23Providing, fixing, applying of contraction joint with suitable type PVC water stopper of 230 mm width and 5 mm thick sealed with 12 mm x 25 mm gun grade polysulphide elastomeric joint sealant of FOSROC make (NITO seal MS 600) over a backer rod and high performance laminated closed cell polyethylene foam joint filler of suitable make (CAPCELL HD-100) in sheet foam having a density of 100 Kg / Cum, non staining with less than 1percentage water absorption, having 97percentage recovery at compression and as directed by Engineer-in-charge.Rmtr600.0600.052.0FalseNoneNoneFalseNoneFalse31200.00
249847375750Nonecode24Filling the gap in between aluminium/ stone/ wood frame and adjacent RCC/Brick/ Stone/ wood/ Ceramic/ Gypsum work by providing weather/structural non sag elastomeric PU sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete, complying to ASTM C920, DIN 18540- F & ISO 11600 Upto 20 mm depth and 20 mm width including cost of materials, labour, usage charges of machinery complete as per specifications.Rmtr296.0296.052.0FalseNoneNoneFalseNoneFalse15392.00
249847475750Nonecode25Providing and fixing in position 25 mm thick sellotex board/CAPCELL HD-100/filler compound as per standards and approved by the Engineer, of required sizes at expansion joints as specified in drawing for Ground level reservoir.Rmtr150.0150.052.0FalseNoneNoneFalseNoneFalse7800.00
249847575750Nonecode26Providing and fixing machine moulded aluminium covering of approved pattern & design, made out of machine cut aluminium sheet and machine holed for receiving dash fastener, over expansion joints on vertical surfaces/ceiling floors, the fixing on plate in one row on one side of joint only shall be done with stainless steel dash fasteners of 8 mm dia and 75 mm long bolt including providing aluminium washers 2 mm thick & 15 mm dia , at a staggered pitch of 200mm centre to centre including drilling holes in the receiving surface and providing expandable plastic sleeves in holes etc. complete as per direction of Engineer-in-charge: Powder coated aluminium sheet 2.5mm thick (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kg544.0544.0280.8FalseNoneNoneFalseNoneFalse152755.20
249847675750Nonecode27Providing and fixing PVC water stopper of suitable type of 230 mm width and 5 mm thickness for construction joints as per detailed technical specifications and as directed by Engineer-in-charge.m310.0310.0789.5FalseNoneNoneFalseNoneFalse244745.00
249847775750Nonecode28Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20percentage E.C. / Lindane 20percentage E.C. at 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.Sqm118.0118.033.75FalseNoneNoneFalseNoneFalse3982.50
249847875750Nonecode29Providing and fixing gauge with iron sheet or enamelled guage plate of 3mm to 4mm thick, 0.23 M width with copper floats indicators and flexible nylone wires, painting figures with approved enamel paint etc. with all lead and lifts, complete for: 0 to 2 mNos4839.04839.02.0FalseNoneNoneFalseNoneFalse9678.00
249847975750Nonecode30Electronic level indicator ( works includes providing necessary wiring, control units, display units and installation and commissioning) The contractor has to arrange for power supply from nearest source inside BWSSB premisesNos95000.095000.01.0FalseNoneNoneFalseNoneFalse95000.00
249848075750Nonecode31Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kg565.0565.02835.0FalseNoneNoneFalseNoneFalse1601775.00
249848175750Nonecode32Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-incharge: Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side including cost of materials, labour, usage charges of machinery complete as per specificationSqm897.0897.011.52FalseNoneNoneFalseNoneFalse10333.440
249848275750Nonecode33Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for: 110mm Pipem288.0288.0100.0FalseNoneNoneFalseNoneFalse28800.00
249848375750Nonecode34Providing and laying 500 micron polyethylene sheet of approved make and quality on binding layer between sub base and structural slab and wherever specified as directed by Engineer.Sqm175.0175.02646.0FalseNoneNoneFalseNoneFalse463050.00
249848475750Nonecode35Providingand fixing slip-strip(2mm thick PVC sheet) of approved quality or equivalent at junction between top of wall and bottom of roof slab in two layers as directed by Engineer, for Ground Level Reservoir.Sqm350.0350.0236.2FalseNoneNoneFalseNoneFalse82670.00
249848575750Nonecode36Providing and fixing 150mm dia. Cast Iron pipe for ventilating shaft 5 M high with specials and cowl and with suitable grips in CC 1:2:4 pillar using 10mm to 20mm graded hard granite, with 15 cms. thick cementconcrete 1:2:4 around upto 1.22 M above the GLR and with a foundation base of 90 x 90 x 90 cms. plastered with 12mm thick CM 1:3 to all exposed faces and linking the shaft to the manholes by means of 150mm dia. GSW pipes and specials, jointing with tar dipped hemp 1:1.5 CM caulking, curing. The cost include all lead and lifts for all materials, earthwork excavations and refilling in all strata, disposal of surplus earth etc.complete.No21087.021087.020.0FalseNoneNoneFalseNoneFalse421740.00
249848675750Nonecode37Providing Sky light as per standard specifications/Vendor Details.No7000.07000.04.0FalseNoneNoneFalseNoneFalse28000.00
249848775750Nonecode38Supplying and fixing lightening arrestor with aluminium strip 25mm x 3mm size including finial and grounding, aluminium strip to be embeded in one of the columns in and independent GI conduit of 40mm dia. pipe suitably jointed by collars with all specials with all lead and lifts etc. complete for: 12 TO 15mNo13889.013889.01.0FalseNoneNoneFalseNoneFalse13889.00
249848875750Nonecode39Earth work in surface excavation for stripping, seating of bund, Road way, by manual means for lowering & leveling the ground for all works other than foundation & depth in all kinds of soil not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work.Sqm91.091.02964.0FalseNoneNoneFalseNoneFalse269724.00
249848975750Nonecode40Manufacturing, providing, trasporting, rolling, lowering, laying, jointing and commissioning of ERW (Electric Resistance Welded)/ SAW (Submerged Arc Welded) MS pipes of Outer dia (Fe-410 grade) conforming to IS 3589-2001 with latest amendments, including perfect linking and welding of joints to correct position, cost of the pipes, conveyance, lead, lift charges, cost of all labour and giving satisfactory hydraulic test as per IS 3589-2001 with latest amendments for test pressure and working pressure both at factory and site etc. complete as per detailed specifications inside with CM 1:1.5 lining of minimum 10mm thick for pipes upto 610mm OD and with minimum 12mm thick beyond 610mm OD and out side with minimum 25mm thick coating in CM 1:3 over 50 x 50mm weld mesh of 13 gauge, including loading and unloading of pipes for the following diameters and specified thickness of plate as noted below, including bailing out of water wherever necessary. (Contractor will make his own arrangements for procuring water for testing)- 1016 mm dia-10 mm thick shell thickness Manifold Pipe of GLRRmtr29595.029595.040.0FalseNoneNoneFalseNoneFalse1183800.00
249849075750Nonecode41711mm dia-7.1mm thick PIPERmtr15786.015786.080.0FalseNoneNoneFalseNoneFalse1262880.00
249849175750Nonecode42323mm dia -7.1mm thick- scour pipe of GLRRmtr7097.07097.0100.0FalseNoneNoneFalseNoneFalse709700.00
249849275750Nonecode43Manufacturing, providing, transporting, rolling, lowering, laying, jointing & testing and commissioning of MS specials of minimum 8 mm thick such as bends, tail pieces, reduces etc. conforming to IS7322:1985 with latest amendments and including perfect linking and welding of joints to correct position including cost and conveyance of materials with all lead and lifts, cost all labour and giving satisfactory hydraulic test as per IS:3589:2001 with latest amendments for test pressure and working pressure both at factory and site etc. complete as per detailed specifications with inside lining two coat of food grade epoxy painting of approved make with each coat of 250 micron thick (after dry) over one coat of food grade epoxy primer of approved make with minimum of 50 micron thick (after dry) and outside 25 mm thick coating in CM 1:3 by providing 50x50 mm weld mesh including loading and unloading of the pipes for the following category to suit PSC / MS / CI / AC / DI / PVC pipes. The rates are inclusive of all taxes and duties. The weight of MS shell only by considered before lining and coating for arriving at the rate. The thickness of plate will be specified by the engineer. (Contractor will make hiw own arrangements for procuring water for testing) for:-Pipe bends,branches, tail pieces, reducers etc. for above 500mm dia pipesKg155.0155.03000.0FalseNoneNoneFalseNoneFalse465000.00
249849375750Nonecode44Supplying and fixing of Double Flanged Resilient seated short body Butterfly valves of various dia as per IS 13095/EN 593 with integral DI seat face with approved soft sealing with body and disc of ductile iron (DI) of grade GGG-40/50, Body seat & Seal retaining ring of SS 304/ CF8, Shaft of stainless steel AISI 410/420/431, Bronze shaft bearing, periferal disk, seal end o rings of EPDM, double eccentric disk. Body and disk should be coated with electrostatcially applied epoxy powder coating with a coating thickness of 250 micron both inside and out side. The rate is inclusive of cost of valve, TP set, galvanised bolts and nuts and rubber insertions. (All the drilled holes in the body shall be of through holes, no tapped holes will be allowed.) -For Valve of PN 16.0 and 1000mmNo.490726.0490726.02.0FalseNoneNoneFalseNoneFalse981452.00
249849475750Nonecode45Supplying and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of ductile iron (DI) conforming to IS- 1865 and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100percentage leak proof with face to face dimensions as per IS 14846-2000 only. The stem sealing should be with toroidal sealing rings (minimum 2 O rings). Body and bonut should be coated with Electrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves, T.P set, galvanized bolts & nuts and rubber insertions etc. but excluding earth work - For Suilce Valve of PN 16.0 and 600mmNo.447406.0447406.08.0FalseNoneNoneFalseNoneFalse3579248.00
249849575750Nonecode46Providing, erecting Electric Valve Actuator for non rising spindle type sluice valve of PN 1 & PN 1.6 rating, totally enclosed, weather-proof and dust proof construction with IP-67, protection class suitable for installation in any position without lubrication, leakage or other operational difficulty with special grease filled gear box and hand wheel for emergency manual operation which will automatically dis-engage on restoration of power to motor and with 10 watt single phase space heater and continuous local mechanical position indicator and individually replaceable counter gear assembly and with two torque and four limit switches with S.S. flap and operated with gear driven cams and of rating 250 Volt, 5 Amp, AC/DC, torque switch dial and with TEFC squirrel cage induction Electric Valve Actuator for non rising spindle type sluice valve, PN 1 & PN 1.6 rating For Valve SizeEach14053.014053.08.0FalseNoneNoneFalseNoneFalse112424.00
249849675750Nonecode47Supplying and fixing kinetic AIR VALVE PN 16.0 for automatic discharge of accumulate air during working condition, conforming to IS 14845 / EN 1074-4. Body and bonnet of DI conforming to IS-1865 of grade GGG-40/50, seals are made of approved EPDM, SS 304 float, guide and internals. Flange drilling according to IS-1538 with appurtenances. complete. Body and bonnet shall be coated with electrostatically applied epoxy powder coating with a coating thickness of 250 micron both inside and outside. For K Air Valves of 150mm diaNo39210.039210.02.0FalseNoneNoneFalseNoneFalse78420.00
249849775750Nonecode48Providing and fixing Wafer type single flange Butterfly valve conforming to relevant IS 13099/9991 EN GGG40/50 with latest amendments as detailed below of the following diameter and types with TP set and conveying to work site, loading and unloading, stacking etc. with all lead and lift. The rate is inclusive of the cost of valve, TP set, rubber insertion, bolts and nuts and excluding earth work excavation.For PN 10.0 (Note: TP set should be considered only for DI pipes estimate. For MS pipes estimates, TP sets cost of corresponding dia shall be deducted from the SR rates of valves and provision for corresponding dia MS flanges should be made in the estimate- For PN 10.0-600mm diaNo75468.075468.02.0FalseNoneNoneFalseNoneFalse150936.00
249849875750Nonecode49Supply, Installation, Commissioning and Testing (for receipt of readings to the Central Server at Cauvery Bhavan) of GPRS + GSM based Multi Track Ultrasonic Bulk Flow Meters to the inlet, outlet, feeder mains and distribution branches ranging from 450mm to 1800mm. The flow meter shall be installed using hot tapping method and existing water supply lines. The data shall by synchronized to existing software. The Ultrasonic Bulk Meters shall comply with the specifications given in the starting of this chapter.- For Multi Track Ultrasonic Bulk Flow Meters, sensors, transmitter, panels etc. for 1000 / 1100mm dia.No523075.0523075.02.0FalseNoneNoneFalseNoneFalse1046150.00
249849975750Nonecode50Supplying S&S RCC SPUN / VIBRATED CAST PIPES (REINFORCED) pipes NP-3 Class conforming to IS:458-1988 with latest amentments using ordinary portland cement, for sanitary works and conveying to work site, rolling and lowering into trenches, laying true to line and level including loading and unloading at both destinations and jointing of pipes and specials, perfect linking of joints with jack to correct position including cost of jointing materials, i.e, rubber rings conforming to IS: 5382 for S&S RCC pipes, with all leads and lifts as directed and giving necessary hydraulic test as per ISS to the required pressure and commissioning etc. complete. (Contractor will make his own arrangements for procuring water for testing). Before the execution of the work, the contractor shall carry out the survey.- RCC NP3 Class pipe of 450 mm dia.(scour pipe)Rmtr2353.02353.030.0FalseNoneNoneFalseNoneFalse70590.00
249850075750Nonecode51Push Buttons (Start & Stop including emergency Stop)Nos607.0607.024.0FalseNoneNoneFalseNoneFalse14568.00
249850175750Nonecode52Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work- In all kinds of soils. Depth upto 1.50mCum484.0484.075.0FalseNoneNoneFalseNoneFalse36300.00
249850275750Nonecode53Supply and laying of following earth wire /strip in horiontal/vertical run in ground/surface/recess including, revitting, soldering, making connection etc as required 8SWG coper wire( 0.155kgs/1mtr)Rmtr86.086.0150.0FalseNoneNoneFalseNoneFalse12900.00
249850375750Nonecode54Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS8130-1984 and (Virgin) PVC insulation sheathed suitablefor working voltage upto 1100 Volts as per IS-694:1990- 3C X 1.5 mm2Rmtr72.072.0250.0FalseNoneNoneFalseNoneFalse18000.00
249850475750Nonecode5510A MPCBNos3230.03230.08.0FalseNoneNoneFalseNoneFalse25840.00
249850575750Nonecode56Security room-Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work-0-3.0 mCum102.0102.084.67FalseNoneNoneFalseNoneFalse8636.340
249850675750Nonecode57Providing and laying in position plain cement concrete of design mix M10 with OPC minimum cement content at 240Kgs using 40 mm and down size graded granite metal course aggregates and the fine agregates machine mixed, concrete laid in layers not exceeding 15 cms. thick, well compacted, in foundation and plinth, including cost of all materials, shuttering, labour, HOM of machinery, curing complete as per specifications.Cum5926.05926.03.74FalseNoneNoneFalseNoneFalse22163.240
249850775750Nonecode58Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum266.0266.071.09FalseNoneNoneFalseNoneFalse18909.940
249850875750Nonecode59Form work fo foundation at 8 percentCum499.84499.844.1FalseNoneNoneFalseNoneFalse2049.3440
249850975750Nonecode60Form work for columns at 70 percentCum4790.14790.11.76FalseNoneNoneFalseNoneFalse8430.5760
249851075750Nonecode61Form work for-Beams at 60 percentCum4105.84105.81.49FalseNoneNoneFalseNoneFalse6117.6420
249851175750Nonecode62Form work-Roof at 50 percentCum3421.53421.54.0FalseNoneNoneFalseNoneFalse13686.00
249851275750Nonecode63Providing and laying in position Reinforced cement concrete of design mix M25 for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)Cum6248.06248.04.1FalseNoneNoneFalseNoneFalse25616.80
249851375750Nonecode64Providing and laying in position Reinforced cement concrete of design mix M 25 for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap /basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)Cum6843.06843.010.4FalseNoneNoneFalseNoneFalse71167.20
249851475750Nonecode65Providing and constructing precast concrete solid blocks with compressive strength not less than 35kg. per sqm with cement mortar 1:4 masonry (quoin, Jamb, closer blocks) with solid concrete blocks of size 40X20X20 cms conforming to IS.2185/ 1965 in superstructure including cost of materials, labour charges, double scaffolding, curing complete as per specifications.Sqm1310.01310.038.12FalseNoneNoneFalseNoneFalse49937.20
249851575750Nonecode66Providing plastering to masonry including providing and removing scaffolding rounding of all corners whenever required, smooth rendering curing etc complete as per specifications with burnt brick masonry plain plastering 12mm thick in CM 1:4 with lime rendering (internal)Sqm312.0312.037.12FalseNoneNoneFalseNoneFalse11581.440
249851675750Nonecode67Providing plastering to masonry including providing and removing double scaffolding rounding of all corners whenever required smooth rendering curing etc., complete as per specifications with burnt brick masonry plain plastering 20mm thick in CM 1:4 (external)Sqm354.0354.056.86FalseNoneNoneFalseNoneFalse20128.440
249851775750Nonecode68Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm127.0127.034.881FalseNoneNoneFalseNoneFalse4429.8870
249851875750Nonecode69Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied at 1.67 ltr/10 m² over and including priming coat of exterior primer applied at 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm174.0174.054.614FalseNoneNoneFalseNoneFalse9502.8360
249851975750Nonecode70Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed at 2 litre per 50 kg of cement or as per direction of Engineer incharge.Sqm800.0800.09.9FalseNoneNoneFalseNoneFalse7920.00
249852075750Nonecode71Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08percentage and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser, treads of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints as per direction of Engineer in charge.Sqm1173.01173.010.0FalseNoneNoneFalseNoneFalse11730.00
249852175750Nonecode72Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-incharge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion : Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) including cost of materials, labour, usage charges of machinery complete as per specifications.Kg452.0452.0220.0FalseNoneNoneFalseNoneFalse99440.00
249852275750Nonecode73Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/ m²) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Sqm988.0988.02.52FalseNoneNoneFalseNoneFalse2489.760
249852375750Nonecode74Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 8 mm thickness (weight not less than 20 kg/ m²) including cost of materials, labour, usage charges of machinery complete as per specifications.Sqm1305.01305.09.45FalseNoneNoneFalseNoneFalse12332.250
249852475750Nonecode75Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400percentage and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats at 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer at150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.Sqm817.0817.011.52FalseNoneNoneFalseNoneFalse9411.840
249852575750Nonecode76Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.Sqm1449.01449.05.4FalseNoneNoneFalseNoneFalse7824.60
249852675750Nonecode77Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20percentage E.C. / Lindane 20percentage E.C. at 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.Sqm118.0118.040.36FalseNoneNoneFalseNoneFalse4762.480
249852775750Nonecode78Providing and laying 230 mm thick rubble packing in plinth with approved stone, set in regular lines, hand-packed, filling the interstices with approved small stone chips and sand, consolidating by ramming or compacting with heavy roller after watering, including spreading 12 mm layer of stone grit on top, etc., complete for all building works as per drawings, details and specifications.(Below grade slab of buildings and other structures)Cum2560.02560.02.69FalseNoneNoneFalseNoneFalse6886.40
249852875750Nonecode79Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation.Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr at Lumen Maintenance of 70percentage, maximum light intensity should be between 60 degrees to 70 degrees. CCT greater than 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location wit minimized minimal tools. LED Light fixture with 200 W System Power consumption. LED Efficiencygreater than1301m/w, nominal CRI greater than75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved/ Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned.LED Streetlight 200 WNos18581.018581.011.0FalseNoneNoneFalseNoneFalse204391.00
249852975750Nonecode80Supplying and Fixing 40 mm dia class A GI pipe bracket upto 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/tubular pole, using suitable clA, bolts, nuts and wiring using suitable capacity wires.Each1478.01478.011.0FalseNoneNoneFalseNoneFalse16258.00
249853075750Nonecode81Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, and 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system and as per technical data approved. (48" Sweep (1200mm)Nos2984.02984.02.0FalseNoneNoneFalseNoneFalse5968.00
249853175750Nonecode82Supply of Automatic Street Light Control System with Optical Micro Sensor, Low voltage / High voltage trip and reset, operating voltage 150 - 280V AC, 50 HZ with suitable SMC enclosure of IP 54 protection, MCBs and contactor suitable to control the load of ...... of single-phase load with necessary clamping arrangements. Makes: As per list of recommended brands-3 KWNos12430.012430.01.0FalseNoneNoneFalseNoneFalse12430.00
249853275750Nonecode831.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 25 Sqmm, 3.5 Core, (12 GI Strips - 4 x 0.8 mm)Km139549.0139549.00.4FalseNoneNoneFalseNoneFalse55819.60
249853375750Nonecode84GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolt, nut, GI Strips and washer completeMinimum Weight of GI Pipe: 7.3 KgNos743.0743.04.0FalseNoneNoneFalseNoneFalse2972.00
249853475750Nonecode85Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg eachNos676.0676.04.0FalseNoneNoneFalseNoneFalse2704.00
249853575750Nonecode86Good Quality Salt for grounding purposes packed in 50 Kg gunny bagBag310.0310.04.0FalseNoneNoneFalseNoneFalse1240.00
249853675750Nonecode87Rod Earthing: Rod type of earthing using 40 mm Dia, 3 Mtr long MS rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal & connected to equipment ground terminal using PVC Al wire as specifiedNos2172.02172.04.0FalseNoneNoneFalseNoneFalse8688.00
249853775750Nonecode885 Bentonite clay slurry for earthing in 50 Kg BagBag368.0368.04.0FalseNoneNoneFalseNoneFalse1472.00
249853875750Nonecode89Supplying of 1 x 4 feet -PVC Batten with integrated LED tube 40 W with high quality diffuser with Life of 25000 burning hours & 70percentage lumen maintenance with CRI greater than 80. Power Input: 220-240Vat 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. 11.3.3 LED light fitting 1 x 4 feet - 36/40 WNos1269.01269.02.0FalseNoneNoneFalseNoneFalse2538.00
249853975750Nonecode90Fixing all types and all capacities of 1x4 / 2x2 LED Light fittings indoor on the wall / ceiling / rafters / girders with necessary supporting frame, using 310.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA.Each490.0490.02.0FalseNoneNoneFalseNoneFalse980.00
249854075750Nonecode91Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing S hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.Nos171.0171.02.0FalseNoneNoneFalseNoneFalse342.00
249854175750Nonecode92Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCBs single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. -SIngle door 8 Way SP & NNos1492.01492.03.0FalseNoneNoneFalseNoneFalse4476.00
249854275750Nonecode93Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC61439-3 and IK 09 tested as perIS/IEC62262 with minimum IP43 protection provided with Polyurethane (PUR)gasket, with suitable earthing system, onwall/ wood board/ flush mounting using required clA, bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3phase Double door with necessary busbar completely wired to use on 440V 3phase 4wire powder coated painting etc.,complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 -4-Way DBNos10329.010329.02.0FalseNoneNoneFalseNoneFalse20658.00
249854375750Nonecode94Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts,nuts,necessary phase separators,handle and wiring complete.Protection of Overload and Short circuit with adjustable thermal magnetic release, Microprocessor releases hall have Earth Fault asperIS/IEC60947-2.(Icu=100percentagelcs).In 4P MCCB,all Poles should haveprotection forShort-Cicrcuit/ Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with livecurrent carrying path with the front cover open).Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism..4P 100 A 25 kA, MCCB (Incomer)Nos8487.08487.02.0FalseNoneNoneFalseNoneFalse16974.00
249854475750Nonecode95Supplying,fixing andwiring Residual current circuit breaker(RCCB)240/450V upto 300mA sensitivity on existing wood/ panel board.-32-40A 2 poleNos4831.04831.05.0FalseNoneNoneFalseNoneFalse24155.00
249854575750Nonecode96Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.-6-32 A SPNos415.0415.05.0FalseNoneNoneFalseNoneFalse2075.00
249854675750Nonecode97Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.- 6-32 A TPNNos1717.01717.05.0FalseNoneNoneFalseNoneFalse8585.00
249854775750Nonecode98Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 40 mm dia 2.5 mm thickRmtr149.0149.0113.0FalseNoneNoneFalseNoneFalse16837.00
249854875750Nonecode99Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.-4-5 WayEach137.0137.05.0FalseNoneNoneFalseNoneFalse685.00
249854975750Nonecode100Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.-6 ModuleEach234.0234.05.0FalseNoneNoneFalseNoneFalse1170.00
249855075750Nonecode101Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.-6A One Way SwitchEach102.0102.010.0FalseNoneNoneFalseNoneFalse1020.00
249855175750Nonecode102Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.-2.5 mm2Rmtr42.042.0100.0FalseNoneNoneFalseNoneFalse4200.00
249855275750Nonecode103Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. For earthing-1.5mm2Rmtr26.026.0100.0FalseNoneNoneFalseNoneFalse2600.00
249855375750Nonecode104Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete.upto 50 mm conduit CC floorRmtr69.069.0130.0FalseNoneNoneFalseNoneFalse8970.00
249855475750Nonecode105Supplying and fixing PVC/metal conduit Deep junction box 19/20 mm deep Junction boxNos49.049.05.0FalseNoneNoneFalseNoneFalse245.00
249855575750Nonecode106Point wiring using Copper wire without switch. supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on theexisting plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Short point upto 3m from tapping point to out let via switch boxPoint285.0285.02.0FalseNoneNoneFalseNoneFalse570.00
249855675750Nonecode107Point wiring using Copper wire without switch. supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on theexisting plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Medium point above 3m upto 6m from tapping point to out let via switch boxNos394.0394.05.0FalseNoneNoneFalseNoneFalse1970.00
249855775750Nonecode108Point wiring using Copper wire without switch. supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on theexisting plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet Long point above 6m upto 10m from tapping point to out let viaswitch boxNos570.0570.05.0FalseNoneNoneFalseNoneFalse2850.00
249855875750Nonecode109providing L shape MS Armature angle of 56feetx5feet and M.S. framing with black colour and MS pillar work for the support of BWSSB signage lightning board size 56 feet x 4 feet, providing and fixing of BWSSB English letters with GI material and acrylic cap size: 28 feet x 4 feet-2 Nos Boards with accessories at top of theNos499000.0499000.01.0FalseNoneNoneFalseNoneFalse499000.00
249855975750Nonecode110Rammurthy nagar GLR to Kalkere-Demolishing cement concrete manually/ by mechanical means including disposal of material to the appropriate disposal area as per direction of Engineer-in-charge.Cum1663.01663.00.5FalseNoneNoneFalseNoneFalse831.50
249856075750Nonecode111Supply, delivery at site, erection, testing and commissioning of brand new best efficient, axial tubular(Tube installed) Non clog submersible pump of required voltage supply frequency 50Hz submersible motor, standard control panel, submersible cable, lifting chain with all its accessories. 4240m3/hr at 3m head.Nos2664825.02664825.02.0FalseNoneNoneFalseNoneFalse5329650.00
249856175750Nonecode112Supply and fixing of ductile iron double flanged swing check vavles with slanted seat or with lever weight with straight disc, with metallic corrosion proof and wear resistant seat faces with nickel overlay micro - finished/ Integral seat with body and disc in Ductile Iron in GGG 40/50 shaft of stainless steel and bearings of zinc free bronze and surface protection with epoxy liquid of GSK quality-For PN 16.0-900mm diaNos.2150202.02150202.02.0FalseNoneNoneFalseNoneFalse4300404.00
249856275750Nonecode113Supplying and fixing of Double Flanged Resilient seated short body Butterfly valves of various dia as per IS 13095/EN 593 with integral DI seat face with approved soft sealing with body and disc of ductile iron (DI) of grade GGG-40/50, Body seat & Seal retaining ring of SS 304/ CF8, Shaft of stainless steel AISI 410/420/431, Bronze shaft bearing, periferal disk, seal end O rings of EPDM, double eccentric disk. Body and disk should be coated with electrostatcially applied epoxy powder coating with a coating thickness of 250 micron both inside and out side. The rate is inclusive of cost of valve, TP set, galvanised bolts and nuts and rubber insertions. (All the drilled holes in the body shall be of through holes, no tapped holes will be allowed.)-For Valve of PN 16.0 and 900mmNo.211932.0211932.02.0FalseNoneNoneFalseNoneFalse423864.00
249856375750Nonecode114Supply, installation, testing & commissioning of flange ends Expansion Bellow as per EJMA standards of overall length of minimum 300 mm, designed for 15 mm axial compression and 5 mm axial extension with tie rods etc. of following MOC & pressure ratings. MOC: Bellows: SA 240 Gr. 304; Internal Sleeve: SA 240 Gr. 304; Weldends: IS 2062 Gr. B; Flanges: IS 2062 Gr. B (Drilling as per IS 1538 / IS 6392 ) & Limit Rods & Nuts: CS - IS 1367.-NB 900 mm, PN - 1.6No57216.057216.02.0FalseNoneNoneFalseNoneFalse114432.00
249856475750Nonecode115Manufacturing, providing, transporting, rolling, lowering, laying, jointing & testing and commissioning of MS specials of minimum 8mm thick such as bends, tail pieces, reduces etc. conforming to IS-7322:1985 with latest amendments and including perfect linking and welding of joints to correct position includng cost and conveyance of materials with all lead and lifts, cost all labour and giving satisfactory hydraulic test as per IS:3589:2001 with latest amendments for test pressure and working pressure both at factory and site etc. complete as per detailed specifications with inside lining two coat of food grade epoxy painting of approved make with each coat of 250 micron thick (after dry) over one coat of food grade epoxy primer of approved make with minium of 50 micron thick (after dry) and outside 25mm thick coating in CM 1:3 by providing 50x50mm weld mesh including loading and unloading of the pipes for the following category to suit PSC / MS / CI / AC / DI / PVC pipes. The weight of MS shell only by considered before lining and coating for arriving at the rate. The thickness of plate will be specified by the engineer. Contractor will make his own arrangements for procuring water for testing) for:Note: 1) For small works where the C.M. lining is not practicable for inside surface of the pipe, food grade expoxy painting of two coat over one coat of epoxy primer may be proposed and got approved. 2) The above rates are applicable only for pipe works.Pipe bends,branches, tail pieces, reducers etc. for above 500mm dia pipesKg155.0155.03000.0FalseNoneNoneFalseNoneFalse465000.00
249856575750Nonecode116Supply, Installation, Commissioning and Testing (for receipt of readings to the Central Server at Cauvery Bhavan) of GPRS + GSM based Multi Track Ultrasonic Bulk Flow Meters to the inlet, outlet, feeder mains and distribution branches ranging from 450mm to 1800mm. The flow meter shall be installed using hot tapping method and existing water supply lines. The data shall by synchronized to existing software. The Ultrasonic Bulk Meters shall comply with the specificationsFor Multi Track Ultrasonic Bulk Flow Meters, sensors, transmitter, panels etc. for 1000 / 1100mm dia.Nos523075.0523075.01.0FalseNoneNoneFalseNoneFalse523075.00
249856675750Nonecode117Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications,including setting out, shoring, strutting, barricading, caution lights,including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in aradius of 50 m and lift upto 1.5 m including cost of labour, tools, usageof machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 mCum102.0102.0568.88FalseNoneNoneFalseNoneFalse58025.760
249856775750Nonecode118Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) (Valve chambers/Butterfly Valve/Flow meter chamber/thrust block)Cum6217.06217.07.41FalseNoneNoneFalseNoneFalse46067.970
249856875750Nonecode119Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.-M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-(Valve chambers/Butterfly Valve/Flow meter chamber/thrust block)Cum6499.06499.045.1FalseNoneNoneFalseNoneFalse293104.90
249856975750Nonecode120Formwork at 3percentage for foundationsCum194.97194.970.45FalseNoneNoneFalseNoneFalse87.73650
249857075750Nonecode121Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6605.06605.036.0FalseNoneNoneFalseNoneFalse237780.00
249857175750Nonecode122Formwork at 10percentage for retaining structuresCum660.5660.53.6FalseNoneNoneFalseNoneFalse2377.80
249857275750Nonecode123Providing and laying in position Reinforced cement concrete M30 Design Mix for top cover flat slab. The Granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes with plastering and smooth finishing in cement mortar 1:3, 12 mm thick for inside surface, labour,centering, scaffolding, strutting, plywood/ steel form work , Usage charges of machinery, curing and all other appurtenances required to complete the work as per design and technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately). (Minimum cement content: 360 kgs (7.20 bags))-Valve chambers/Butterfly Valve/Flow meter chamberCum13433.013433.07.35FalseNoneNoneFalseNoneFalse98732.550
249857375750Nonecode124Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification-For valve chambersKg79.0179.018109.99FalseNoneNoneFalseNoneFalse640770.30990
249857475750Nonecode125Supplying of on load change over switches 4poles ,AC-23ADuty,415V,50Hz,AC Supply.With all accessories.(SMEnclosureSheet Metal Execution)- 125 ANos.12324.012324.01.0FalseNoneNoneFalseNoneFalse12324.00
249857575750Nonecode1261.1 kV Class Armoured Aluminium Cable with glands/lugs/ferrules-4C x 95 Sq mmRmtr762.0762.064.0FalseNoneNoneFalseNoneFalse48768.00
249857675750Nonecode127supply,Transportation, Installation, Testing and Commissioning of 11/0.433 KV TRANSFORMER with all test reports. The Transformer shall be designed and manufactured as per Energy Efficiency Level-2 at basic Insulation level conforming to ISS 2026 (Part ItoPart-II) with latest amended and as per IS 1180 Part-I : 2014 latest amended, OCTC with initial filling of oil as per IS 335-1993. The basic details of the Transformer are as under.1. Quantity : 1 2. Rated KVA: KVA 3. Service & Location: Continuous Outdoor Distribution Transformer 4. Mounting: Plinth. 5. Wound: Copper Double wound 6. Type: Core type oil immersed 7. Cooling: ONAN 8. Temp Rise: 40 C in oil, 45 degree C by resistance 9. Vector Group, Dyn 11 10. Primary Connection: Delta 11. Nominal Voltage / Current: 12. Highest system Voltage: 12000V 13. Primary Frequency :50 HZ plus or minus 3percentage 14. Number of Phases: 3 15. Primary wires: 3 16. Secondary connection: Star 17. Secondary Volts / Current : 433V 18. Secondary phases: 3 19. Secondary wires: 4 20. Taps on primary winding for primary voltage variation: plus5percentage to - 10percentage in steps of 2.5percentage of 7 position (6 Steps) 21. Terminal arrangement. a. HV: HT terminal box as per the site condition. b. LV: Cable box suitable to receive -Sq.mm XLPE cable 22. LV: One separate terminal for earthing. 23. Total Losses at 50percentage Loading [Watts] [Max] - as per IS 24. Total Losses at 100percentage Loading [Watts] [Max]- as per IS 25.Percentage Impedance at 75 deg. C at -as per IS 26. No Load current: Less than 2percentage of full load current. 27. Standard Fittings & Accessories. a. Rating and terminal marking plate: One b. Lifting Lugs: Two c. Off-circuit tap switch: One. d. Earthing Terminals : Two e. Radiators (Attachable): Adequate f. Explosion vent with Diaphragm : One g. Conservator with Drain plug: one h. Oil filling hole with cap :One i. Oil level indicator: Onej. Dehydrating Silica gel Breather: One k. Terminal Arrangement: HV With Terminal Box l. Terminal Arrangement: LV Cable Box m. Separate Neutral Bushing : One n. Drain cum filter valve with blanking plate: One o. Air release device: One, p. Thermometer Pocket: One q. Four: Unidirectional flat rollers r. One :10Cm dial thermometer (Rigid stem type)-160 KVA Copper Wound TransformerNo.717255.0717255.01.0FalseNoneNoneFalseNoneFalse717255.00
249857775750Nonecode128Heat Shrinkable Indoor Type Cable Termination Kit for XLPE CableNo4816.04816.01.0FalseNoneNoneFalseNoneFalse4816.00
249857875750Nonecode129Heat Shrinkable Outdoor Type Cable Termination Kit for XLPE CableNo4428.04428.01.0FalseNoneNoneFalseNoneFalse4428.00
249857975750Nonecode130Heat shrinkable Type Terminations LT UG CableNo333.0333.02.0FalseNoneNoneFalseNoneFalse666.00
249858075750Nonecode131Cable covering tiles 250x125x40 mm (Qty=4000 No.. per km)No.8.488.481.0FalseNoneNoneFalseNoneFalse8.480
249858175750Nonecode132Route and Joint Indicating Stones (Qty=20 No.. per km)No.110.24110.245.0FalseNoneNoneFalseNoneFalse551.20
249858275750Nonecode133Transformer Structure Kit with Three H Frames without tranformer seating and seating Angle support cross arm for 63/100/250/500kVA (UG Cable) MSPer Structure21310.121310.11.0FalseNoneNoneFalseNoneFalse21310.10
249858375750Nonecode13411kV Lightning Arrestor, Metal oxide, 9kV, 5kA ceramic type with ground disconnectorSet1562.131562.131.0FalseNoneNoneFalseNoneFalse1562.130
249858475750Nonecode13511kV,45KN Disc Insulator, porcelainSet398.56398.562.0FalseNoneNoneFalseNoneFalse797.120
249858575750Nonecode136HT Top support with bolts, nuts & washersSet202.26202.262.0FalseNoneNoneFalseNoneFalse404.520
249858675750Nonecode137Alkathene Tube 19mm dia and in coils of 30Mtrs.No.427.39427.391.0FalseNoneNoneFalseNoneFalse427.390
249858775750Nonecode13811kV, 200A single break GOSSet8543.08543.01.0FalseNoneNoneFalseNoneFalse8543.00
249858875750Nonecode13911kV Soild core type HG fuse UnitSet1053.141053.141.0FalseNoneNoneFalseNoneFalse1053.140
249858975750Nonecode140Rabbit ACSR ConductorMtr52.1652.16200.0FalseNoneNoneFalseNoneFalse10432.00
249859075750Nonecode141Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work- In all kinds of soils. Depth upto 1.50mCum484.0484.037.5FalseNoneNoneFalseNoneFalse18150.00
249859175750Nonecode1421.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975-300 Sqmm, 3.5 Core, (32 GI Strips - 4 x 0.8 mm)Rmtr1066.011066.01100.0FalseNoneNoneFalseNoneFalse106601.00
249859275750Nonecode14395 Sqmm, 3.5 Core, (21 GI Strips - 4 x 0.8 mm)Rmtr373.21373.2135.0FalseNoneNoneFalseNoneFalse13062.350
249859375750Nonecode144Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff- 35 to 95 SqmmRmtr31.1431.1425.0FalseNoneNoneFalseNoneFalse778.50
249859475750Nonecode145120 to 240 SqmmRmtr32.2832.2825.0FalseNoneNoneFalseNoneFalse807.00
249859575750Nonecode146Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100percentage lcs). In 4P MCCB, all Poles should have protection for Short- icrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.- Four pole-320-400 A 50 kANos30111.030111.01.0FalseNoneNoneFalseNoneFalse30111.00
249859675750Nonecode147160 A 25 kANos13447.013447.02.0FalseNoneNoneFalseNoneFalse26894.00
249859775750Nonecode148Supply and delivery of floor mounted type FCMA Air/ Oil Cooled soft starter suitable for the LT motor offered for operation in AC three Phase 50Hz (+/- 5percentage), 415V(+/-10percentage) including line contactors suitable for next standard higher KW rating, Over load relay, instrument panel with frequency meter, Ammeter, Voltmeter, indicating lamp 6Nos, LED ON/OFF type and Start /Stop push button.-Nos366112.0366112.02.0FalseNoneNoneFalseNoneFalse732224.00
249859875750Nonecode149Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C.-On/OFF/TRIP/R/Y/B indicatorsNos515.0515.06.0FalseNoneNoneFalseNoneFalse3090.00
249859975750Nonecode150Supplying, fixing and wiring 50/5 to 400/5A 5VA burden Current Transformer Class 0.5 accuracy with Tape Wound.Nos562.0562.03.0FalseNoneNoneFalseNoneFalse1686.00
249860075750Nonecode151Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, kVA, kWH, kVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracyNos9315.09315.01.0FalseNoneNoneFalseNoneFalse9315.00
249860175750Nonecode152Supplying, fixing and wiring 3 Phase Digital Ammeter / VoltmeterNos1425.01425.02.0FalseNoneNoneFalseNoneFalse2850.00
249860275750Nonecode153Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia.Nos3750.03750.05.0FalseNoneNoneFalseNoneFalse18750.00
249860375750Nonecode154Supplying and running of GI strips for grounding connections, using necessary fixing materials as required.-50 x 6 mm GI (MCC Panels, Main Motors etc.)Rmtr218.0218.020.0FalseNoneNoneFalseNoneFalse4360.00
249860475750Nonecode15565 x 10 mm GI (Trf. Body, neutral, Main Earth Grid etc.)Rmtr975.0975.020.0FalseNoneNoneFalseNoneFalse19500.00
249860575750Nonecode156The cost for fabrication panel, Copper busbars, interconnecting cables,mounting fasterners, terminal box etc. Installation, Commissioning and transportationJob240000.0240000.01.0FalseNoneNoneFalseNoneFalse240000.00
249860675750Nonecode157Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kg113.0113.01120.0FalseNoneNoneFalseNoneFalse126560.00
249860775750Nonecode158Providing and fixing 6mm Clear/opal white/solar bronze/blue/green tinted Multi wall poly carbonate sheet for Tubular structure. The work including cost of all materials, labour charges, and hire charges of machinery for cutting, welding, grinding and erection equipments, with all lead and lifts, transportation, loading and unloading and all other incidental charges etc. complete as per specification and directions of the engineer in charge of the work.Sqmm127.0127.016.0FalseNoneNoneFalseNoneFalse2032.00
249860875750Nonecode1592mmthickperforatedcableGItraywithonexistingMSanglesupportusing necessary GI bolts/nuts and washer or welding as required.Rmtr587.0587.0150.0FalseNoneNoneFalseNoneFalse88050.00
249860975750Nonecode1601.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975-16 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm)Rmtr141.84141.84150.0FalseNoneNoneFalseNoneFalse21276.00
249861075750Nonecode161Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff-2.5 to 25 SqmmRmtr20.8920.89150.0FalseNoneNoneFalseNoneFalse3133.50
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17073057010000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17073057010000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17073057010000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17073057270000NoneNoneELIGIBILITYAll terms and conditions as per bid documentNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneAs prime contractor should have satisfactorily completed at least one similar work of construction of GLR with chlorination system and allied works of value not less than Rs. 6.18 crores.ii.The contractor should have constructed and commissioned 10 ML capacity RCC water retaining reservoir with RCC roof.iii Installation of pumps of minimum 3 Nos. with 70HP capacity under water supply schemePast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneExecuted in any one year, the following minimum quantities of work:a. RCC of M 30 with shuttering:1900 cum b. MS pipeline commissioned of 350mm dia & above:150 RmtPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneAchieved in at least two financial years a minimum financial turnover (in all classes of civil engineering construction works only) of Rs. 16.48 crores.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. 2.75 croresFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneAssessed available tender capacity (AxNx1.5 - B )Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- demonstrate on company letter head with signature
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover Certificate with balance sheets certified by CATrueTechnical Bid
Contractors should have registration in KPWD of State Government organization, public sector under takings, other state Governments.TrueTechnical Bid
Equipment details as per bid doceumentTrueTechnical Bid
Qualification criteria as per bid documentTrueTechnical Bid
Form of tenderTrueTechnical Bid
Work done with relevant work ordersTrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1707306536000
version0
createdDateNone
modifiedDateNone
blockNumberO/o of CE (P), BWSSB, Cauvery Bhavan,
streetNone
cityBangalore
stateKarnataka
pin560009
tenderRecallDTONone