1707305700000 | 1 | None | None | Construction of new tanks | The work of construction of Construction of 13.5 ML GLR at Kalkere with pumping station at Rammurthy Nagar | 104678769.11 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2498450 | 75750 | None | code01 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m | Cum | 102.0 | 102.0 | 8071.24 | False | None | None | False | None | False | 823266.48 | 0 | 2498451 | 75750 | None | code02 | Earth work excavation for pipeline trenches by mechanical means as per drawing and technical specification, including setting out, construction of shoring, strutting, cost of blasting materials, barricading, caution lights, bracing, using sight rails & bonding rods at every 100 mm wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work and all other appurtenances to complete in the following strata. Hard rock (blasting prohibited) depth exceeding 3m but not exceeding 4.5m | Cum | 1196.0 | 1196.0 | 1614.248 | False | None | None | False | None | False | 1930640.608 | 0 | 2498452 | 75750 | None | code03 | Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 266.0 | 266.0 | 1014.0 | False | None | None | False | None | False | 269724.0 | 0 | 2498453 | 75750 | None | code04 | Disposal off the excess excavated earth of all types by vehicle including loading,unloading with all lead and lifts, labour, HOM of machineries etc.( Debries) for: 10km | Cum | 230.88 | 230.88 | 8671.488 | False | None | None | False | None | False | 2002073.14944 | 0 | 2498454 | 75750 | None | code05 | Disposing the existing construction waste dumped at site to a suitable location within a radius of 20 KM in all types of earth by vehicle including loading,unloading with all lead and lifts, labour, HOM of machineries etc.( Debries) for: 2.0km | Cum | 418.08 | 418.08 | 3000.0 | False | None | None | False | None | False | 1254240.0 | 0 | 2498455 | 75750 | None | code06 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of
all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)-Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6217.0 | 6217.0 | 756.276 | False | None | None | False | None | False | 4701767.892 | 0 | 2498456 | 75750 | None | code07 | Providing and laying in position cement concrete of design mix M30 with 20mm nominal size graded crushed coarse aggregates for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) | Cum | 6499.0 | 6499.0 | 1530.24 | False | None | None | False | None | False | 9945029.76 | 0 | 2498457 | 75750 | None | code08 | Formwork at3percentage for foundations | Cum | 194.97 | 194.97 | 1530.24 | False | None | None | False | None | False | 298350.8928 | 0 | 2498458 | 75750 | None | code09 | Providing and laying in Reinforced cement concrete of design mix M30 for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per
technical specifications. (The cost of steel reinforcement & formwork
to be paid separately) | Cum | 6605.0 | 6605.0 | 1117.23 | False | None | None | False | None | False | 7379304.15 | 0 | 2498459 | 75750 | None | code10 | Formwork at 10percentage for retaining structures | Cum | 660.5 | 660.5 | 1117.23 | False | None | None | False | None | False | 737930.415 | 0 | 2498460 | 75750 | None | code01 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (coulmns and head room) | Cum | 6742.0 | 6742.0 | 729.09 | False | None | None | False | None | False | 4915524.78 | 0 | 2498461 | 75750 | None | code12 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification- building works | Kg | 89.45 | 89.45 | 406787.2 | False | None | None | False | None | False | 36387115.04 | 0 | 2498462 | 75750 | None | code13 | Providing and constructing precast concrete solid blocks with compressive strength not less than 35kg. per sqm with cement mortar 1:4 masonry (quoin, Jamb, closer blocks) with solid concrete blocks of size 40X20X20 cms conforming to IS.2185/ 1965 in superstructure including cost of materials, labour charges, double scaffolding, curing complete as per specifications. | Sqm | 1310.0 | 1310.0 | 126.6 | False | None | None | False | None | False | 165846.0 | 0 | 2498463 | 75750 | None | code14 | Providing plastering to masonry including providing and removing double scaffolding rounding of all corners whenever required smooth rendering curing etc., complete as per specifications with burnt brick masonry plain plastering 20mm thick in CM 1:4 (external) | Sqm | 354.0 | 354.0 | 253.2 | False | None | None | False | None | False | 89632.8 | 0 | 2498464 | 75750 | None | code15 | Providing and appying integral crystalline slurry of hydropholic in nature for waterproofing treatment to RCC structures like floor and walls of reservoirs, sewage, effluent and water treatment plants, overhead tanks etc., prepared by mixing in the ratio of 5:2 (5 parts integral crystalline slurry 2 parts water) for horizontal and vertical surfaces and applying the same from negative (internal) side with the help of synthetic fibre brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i., by reducing permeability of concrete by more than 90percentage compared with control concrete as per DIN 1048 and resistant to 16 Bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self healing of cracks upto width of 0.5mm. The work shall be carried out all complete as per specification and the direction of the Engineer in charge. The product performance shall carry guarantee for 10 years against any leakage.
For horizontal and vertical surfaces in two coats at 0.7kg per sqm per coat. | Sqm | 433.0 | 433.0 | 3391.7 | False | None | None | False | None | False | 1468606.1 | 0 | 2498465 | 75750 | None | code16 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 127.0 | 127.0 | 1442.0 | False | None | None | False | None | False | 183134.0 | 0 | 2498466 | 75750 | None | code17 | Providing and laying in position yelahanka tiles of size 125 x 250mm of approved quality and make, over a bed of cement mortar 1:3 with thickness varying from 100mm to 25mm including weather proof course and pointed with cement mortar 1:3 mix with red oxide including curing cost of materials, labour complete as per specifications. | Sqm | 1100.0 | 1100.0 | 2444.0 | False | None | None | False | None | False | 2688400.0 | 0 | 2498467 | 75750 | None | code18 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less
than 10kg/ m²) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 988.0 | 988.0 | 1.08 | False | None | None | False | None | False | 1067.04 | 0 | 2498468 | 75750 | None | code19 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete | Nos. | 1114.0 | 1114.0 | 2.0 | False | None | None | False | None | False | 2228.0 | 0 | 2498469 | 75750 | None | code20 | Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete including cost of materials, labour, usage charges of machinery complete as per specifications. | Nos. | 437.0 | 437.0 | 2.0 | False | None | None | False | None | False | 874.0 | 0 | 2498470 | 75750 | None | code21 | Supplying and fixing PVC encapsulated CI rungs to shapes and at locations specified in drawings and specifications for Valve chambers | Nos | 40.0 | 40.0 | 5.0 | False | None | None | False | None | False | 200.0 | 0 | 2498471 | 75750 | None | code22 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/m²) including cost of materials, labour, usage charges of machinery complete as per specifications. | Sqm | 1171.0 | 1171.0 | 0.252 | False | None | None | False | None | False | 295.092 | 0 | 2498472 | 75750 | None | code23 | Providing, fixing, applying of contraction joint with suitable type PVC water stopper of 230 mm width and 5 mm thick sealed with 12 mm x 25 mm gun grade polysulphide elastomeric joint sealant of FOSROC make (NITO seal MS 600) over a backer rod and high performance laminated closed cell polyethylene foam joint filler of suitable make (CAPCELL HD-100) in sheet foam having a density of 100 Kg / Cum, non staining with less than 1percentage water absorption, having 97percentage recovery at compression and as directed by Engineer-in-charge. | Rmtr | 600.0 | 600.0 | 52.0 | False | None | None | False | None | False | 31200.0 | 0 | 2498473 | 75750 | None | code24 | Filling the gap in between aluminium/ stone/ wood frame and adjacent RCC/Brick/ Stone/ wood/ Ceramic/ Gypsum work by providing weather/structural non sag elastomeric PU sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete, complying to ASTM C920, DIN 18540- F & ISO 11600 Upto 20 mm depth and 20 mm width including cost of materials, labour, usage charges of machinery complete as per specifications. | Rmtr | 296.0 | 296.0 | 52.0 | False | None | None | False | None | False | 15392.0 | 0 | 2498474 | 75750 | None | code25 | Providing and fixing in position 25 mm thick sellotex board/CAPCELL HD-100/filler compound as per standards and approved by the Engineer, of required sizes at expansion joints as specified in drawing for Ground level reservoir. | Rmtr | 150.0 | 150.0 | 52.0 | False | None | None | False | None | False | 7800.0 | 0 | 2498475 | 75750 | None | code26 | Providing and fixing machine moulded aluminium covering of
approved pattern & design, made out of machine cut aluminium sheet and machine holed for receiving dash fastener, over expansion joints on vertical surfaces/ceiling floors, the fixing on plate in one row on one side of joint only shall be done with stainless steel dash fasteners of 8 mm dia and 75 mm long bolt including providing aluminium washers
2 mm thick & 15 mm dia , at a staggered pitch of 200mm centre to centre including drilling holes in the receiving surface and providing expandable plastic sleeves in holes etc. complete as per direction of Engineer-in-charge: Powder coated aluminium sheet 2.5mm thick (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 544.0 | 544.0 | 280.8 | False | None | None | False | None | False | 152755.2 | 0 | 2498476 | 75750 | None | code27 | Providing and fixing PVC water stopper of suitable type of 230 mm width and 5 mm thickness for construction joints as per detailed technical specifications and as directed by Engineer-in-charge. | m | 310.0 | 310.0 | 789.5 | False | None | None | False | None | False | 244745.0 | 0 | 2498477 | 75750 | None | code28 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20percentage E.C. / Lindane 20percentage E.C. at 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. | Sqm | 118.0 | 118.0 | 33.75 | False | None | None | False | None | False | 3982.5 | 0 | 2498478 | 75750 | None | code29 | Providing and fixing gauge with iron sheet or enamelled guage plate of 3mm to 4mm thick, 0.23 M width with copper floats indicators and flexible nylone wires, painting figures with approved enamel paint etc. with all lead and lifts, complete for: 0 to 2 m | Nos | 4839.0 | 4839.0 | 2.0 | False | None | None | False | None | False | 9678.0 | 0 | 2498479 | 75750 | None | code30 | Electronic level indicator ( works includes providing necessary wiring, control units, display units and installation and commissioning) The contractor has to arrange for power supply from nearest source inside BWSSB premises | Nos | 95000.0 | 95000.0 | 1.0 | False | None | None | False | None | False | 95000.0 | 0 | 2498480 | 75750 | None | code31 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 565.0 | 565.0 | 2835.0 | False | None | None | False | None | False | 1601775.0 | 0 | 2498481 | 75750 | None | code32 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-incharge: Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side including cost of materials, labour, usage charges of machinery complete as per specification | Sqm | 897.0 | 897.0 | 11.52 | False | None | None | False | None | False | 10333.44 | 0 | 2498482 | 75750 | None | code33 | Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for: 110mm Pipe | m | 288.0 | 288.0 | 100.0 | False | None | None | False | None | False | 28800.0 | 0 | 2498483 | 75750 | None | code34 | Providing and laying 500 micron polyethylene sheet of approved make and quality on binding layer between sub base and structural slab and wherever specified as directed by Engineer. | Sqm | 175.0 | 175.0 | 2646.0 | False | None | None | False | None | False | 463050.0 | 0 | 2498484 | 75750 | None | code35 | Providingand fixing slip-strip(2mm thick PVC sheet) of approved quality or equivalent at junction between top of wall and bottom of roof slab in two layers as directed by Engineer, for Ground Level Reservoir. | Sqm | 350.0 | 350.0 | 236.2 | False | None | None | False | None | False | 82670.0 | 0 | 2498485 | 75750 | None | code36 | Providing and fixing 150mm dia. Cast Iron pipe for ventilating shaft 5 M high with specials and cowl and with suitable grips in CC 1:2:4 pillar using 10mm to 20mm graded hard granite, with 15 cms. thick cementconcrete 1:2:4 around upto 1.22 M above the GLR and with a foundation base of 90 x 90 x 90 cms. plastered with 12mm thick CM 1:3 to all exposed faces and linking the shaft to the manholes by means of 150mm dia. GSW pipes and specials, jointing with tar dipped hemp 1:1.5 CM caulking, curing. The cost include all lead and lifts for all materials, earthwork excavations and refilling in all strata, disposal of surplus earth etc.complete. | No | 21087.0 | 21087.0 | 20.0 | False | None | None | False | None | False | 421740.0 | 0 | 2498486 | 75750 | None | code37 | Providing Sky light as per standard specifications/Vendor Details. | No | 7000.0 | 7000.0 | 4.0 | False | None | None | False | None | False | 28000.0 | 0 | 2498487 | 75750 | None | code38 | Supplying and fixing lightening arrestor with aluminium strip 25mm x 3mm size including finial and grounding, aluminium strip to be embeded in one of the columns in and independent GI conduit of 40mm dia. pipe suitably jointed by collars with all specials with all lead and lifts etc.
complete for: 12 TO 15m | No | 13889.0 | 13889.0 | 1.0 | False | None | None | False | None | False | 13889.0 | 0 | 2498488 | 75750 | None | code39 | Earth work in surface excavation for stripping, seating of bund, Road way, by manual means for lowering & leveling the ground for all works other than foundation & depth in all kinds of soil not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. | Sqm | 91.0 | 91.0 | 2964.0 | False | None | None | False | None | False | 269724.0 | 0 | 2498489 | 75750 | None | code40 | Manufacturing, providing, trasporting, rolling, lowering, laying, jointing and commissioning of ERW (Electric Resistance Welded)/ SAW (Submerged Arc Welded) MS pipes of Outer dia (Fe-410 grade) conforming to IS 3589-2001 with latest amendments, including perfect linking and welding of joints to correct position, cost of the pipes, conveyance, lead, lift charges, cost of all labour and giving satisfactory hydraulic test as per IS 3589-2001 with latest amendments for test pressure and working pressure both at factory and site etc. complete as per detailed specifications inside with CM 1:1.5 lining of minimum 10mm thick for pipes upto 610mm OD and with minimum 12mm thick beyond 610mm OD and out side with minimum 25mm thick coating in CM 1:3 over 50 x 50mm weld mesh of 13 gauge, including loading and unloading of pipes for the following diameters and specified thickness of plate as noted below, including bailing out of water wherever necessary. (Contractor will make his own arrangements for procuring water for testing)- 1016 mm dia-10 mm thick shell thickness Manifold Pipe of GLR | Rmtr | 29595.0 | 29595.0 | 40.0 | False | None | None | False | None | False | 1183800.0 | 0 | 2498490 | 75750 | None | code41 | 711mm dia-7.1mm thick PIPE | Rmtr | 15786.0 | 15786.0 | 80.0 | False | None | None | False | None | False | 1262880.0 | 0 | 2498491 | 75750 | None | code42 | 323mm dia -7.1mm thick- scour pipe of GLR | Rmtr | 7097.0 | 7097.0 | 100.0 | False | None | None | False | None | False | 709700.0 | 0 | 2498492 | 75750 | None | code43 | Manufacturing, providing, transporting, rolling, lowering, laying, jointing & testing and commissioning of MS specials of minimum 8 mm thick such as bends, tail pieces, reduces etc. conforming to IS7322:1985 with latest amendments and including perfect linking and welding of joints to correct position including cost and conveyance of materials with all lead and lifts, cost all labour and giving satisfactory hydraulic test as per IS:3589:2001 with latest amendments for test pressure and working pressure both at factory and site etc. complete as per detailed specifications with inside lining two coat of food grade epoxy painting of approved make with each coat of 250 micron thick (after dry) over one coat of food grade epoxy primer of approved make with minimum of 50 micron thick (after dry) and outside 25 mm thick coating in CM 1:3 by providing 50x50 mm weld mesh including loading and unloading of the pipes for the following category to suit PSC / MS / CI / AC / DI / PVC pipes. The rates are inclusive of all taxes and duties. The weight of MS shell only by considered before lining and coating for arriving at the rate. The thickness of plate will be specified by the engineer. (Contractor will make hiw own arrangements for procuring water for testing) for:-Pipe bends,branches, tail pieces, reducers etc. for above 500mm dia pipes | Kg | 155.0 | 155.0 | 3000.0 | False | None | None | False | None | False | 465000.0 | 0 | 2498493 | 75750 | None | code44 | Supplying and fixing of Double Flanged Resilient seated short body Butterfly valves of various dia as per IS 13095/EN 593 with integral DI seat face with approved soft sealing with body and disc of ductile iron (DI) of grade GGG-40/50, Body seat & Seal retaining ring of SS 304/ CF8, Shaft of stainless steel AISI 410/420/431, Bronze shaft bearing, periferal disk, seal end o rings of EPDM, double eccentric disk. Body and disk should be coated with electrostatcially applied epoxy powder coating with a coating thickness of 250 micron both inside and out side. The rate is inclusive of cost of valve, TP set, galvanised bolts and nuts and rubber insertions. (All the drilled holes in the body shall be of through holes, no tapped holes will be allowed.) -For Valve of PN 16.0 and 1000mm | No. | 490726.0 | 490726.0 | 2.0 | False | None | None | False | None | False | 981452.0 | 0 | 2498494 | 75750 | None | code45 | Supplying and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of ductile iron (DI) conforming to IS- 1865 and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100percentage leak proof with face to face dimensions as per IS 14846-2000 only. The stem sealing should be with toroidal sealing rings (minimum 2 O rings). Body and bonut should be coated with Electrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves, T.P set, galvanized bolts & nuts and rubber insertions etc. but excluding earth work - For Suilce Valve of PN 16.0 and 600mm | No. | 447406.0 | 447406.0 | 8.0 | False | None | None | False | None | False | 3579248.0 | 0 | 2498495 | 75750 | None | code46 | Providing, erecting Electric Valve Actuator for non rising spindle type sluice valve of PN 1 & PN 1.6
rating, totally enclosed, weather-proof and dust proof construction with IP-67, protection class suitable for
installation in any position without lubrication, leakage or other operational difficulty with special
grease filled gear box and hand wheel for emergency manual operation which will automatically dis-engage on restoration of power to motor and with 10 watt single phase space heater and continuous local mechanical position indicator and individually replaceable counter gear assembly and with two torque and four limit switches with S.S. flap and operated with gear driven cams and of rating 250 Volt, 5 Amp, AC/DC, torque switch dial and with TEFC squirrel cage induction Electric Valve Actuator for non rising spindle type sluice valve, PN 1 & PN 1.6 rating For Valve Size | Each | 14053.0 | 14053.0 | 8.0 | False | None | None | False | None | False | 112424.0 | 0 | 2498496 | 75750 | None | code47 | Supplying and fixing kinetic AIR VALVE PN 16.0 for automatic discharge of accumulate air during working condition, conforming to IS 14845 / EN 1074-4. Body and bonnet of DI conforming to IS-1865 of grade GGG-40/50, seals are made of approved EPDM, SS 304 float, guide and internals. Flange drilling according to IS-1538 with appurtenances. complete. Body and bonnet shall be coated with electrostatically applied epoxy powder coating with a coating thickness of 250 micron both inside and outside. For K Air Valves of 150mm dia | No | 39210.0 | 39210.0 | 2.0 | False | None | None | False | None | False | 78420.0 | 0 | 2498497 | 75750 | None | code48 | Providing and fixing Wafer type single flange Butterfly valve conforming to relevant IS 13099/9991 EN GGG40/50 with latest amendments as detailed below of the following diameter and types with TP set and conveying to work site, loading and unloading, stacking etc. with all lead and lift. The rate is inclusive of the cost of valve, TP set, rubber insertion, bolts and nuts and excluding earth work excavation.For PN 10.0 (Note: TP set should be considered only for DI pipes estimate. For MS pipes estimates, TP sets cost of corresponding dia shall be deducted from the SR rates of valves and provision for corresponding dia MS flanges should be made in the estimate- For PN 10.0-600mm dia | No | 75468.0 | 75468.0 | 2.0 | False | None | None | False | None | False | 150936.0 | 0 | 2498498 | 75750 | None | code49 | Supply, Installation, Commissioning and Testing (for receipt of readings to the Central Server at Cauvery Bhavan) of GPRS + GSM based Multi Track Ultrasonic Bulk Flow Meters to the inlet, outlet, feeder mains and distribution branches ranging from 450mm to 1800mm. The flow meter shall be installed using hot tapping method and existing water supply lines. The data shall by synchronized to existing software. The Ultrasonic Bulk Meters shall comply with the specifications given in the starting of this chapter.- For Multi Track Ultrasonic Bulk Flow Meters, sensors, transmitter, panels etc. for 1000 / 1100mm dia. | No | 523075.0 | 523075.0 | 2.0 | False | None | None | False | None | False | 1046150.0 | 0 | 2498499 | 75750 | None | code50 | Supplying S&S RCC SPUN / VIBRATED CAST PIPES (REINFORCED) pipes NP-3 Class conforming to IS:458-1988 with latest amentments using ordinary portland cement, for sanitary works and conveying to work site, rolling and lowering into trenches, laying true to line and level including loading and unloading at both destinations and jointing of pipes and specials, perfect linking of joints with jack to correct position including cost of jointing materials, i.e, rubber rings conforming to IS: 5382 for S&S RCC pipes, with all leads and lifts as directed and giving necessary hydraulic test as per ISS to the required pressure and commissioning etc. complete. (Contractor will make his own arrangements for procuring water for testing). Before the execution of the work, the contractor shall carry out the survey.- RCC NP3 Class pipe of 450 mm dia.(scour pipe) | Rmtr | 2353.0 | 2353.0 | 30.0 | False | None | None | False | None | False | 70590.0 | 0 | 2498500 | 75750 | None | code51 | Push Buttons (Start & Stop including emergency Stop) | Nos | 607.0 | 607.0 | 24.0 | False | None | None | False | None | False | 14568.0 | 0 | 2498501 | 75750 | None | code52 | Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in
depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work- In all kinds of soils. Depth upto 1.50m | Cum | 484.0 | 484.0 | 75.0 | False | None | None | False | None | False | 36300.0 | 0 | 2498502 | 75750 | None | code53 | Supply and laying of following earth wire /strip in horiontal/vertical run in ground/surface/recess including, revitting, soldering, making connection etc as required 8SWG coper wire( 0.155kgs/1mtr) | Rmtr | 86.0 | 86.0 | 150.0 | False | None | None | False | None | False | 12900.0 | 0 | 2498503 | 75750 | None | code54 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS8130-1984 and (Virgin) PVC insulation sheathed suitablefor working voltage upto 1100 Volts as per IS-694:1990- 3C X 1.5 mm2 | Rmtr | 72.0 | 72.0 | 250.0 | False | None | None | False | None | False | 18000.0 | 0 | 2498504 | 75750 | None | code55 | 10A MPCB | Nos | 3230.0 | 3230.0 | 8.0 | False | None | None | False | None | False | 25840.0 | 0 | 2498505 | 75750 | None | code56 | Security room-Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work-0-3.0 m | Cum | 102.0 | 102.0 | 84.67 | False | None | None | False | None | False | 8636.34 | 0 | 2498506 | 75750 | None | code57 | Providing and laying in position plain cement concrete of design mix M10 with OPC minimum cement content at 240Kgs using 40 mm and down size graded granite metal course aggregates and the fine agregates machine mixed, concrete laid in layers not exceeding 15 cms. thick, well compacted, in foundation and plinth, including cost of all materials, shuttering, labour, HOM of machinery, curing complete as per specifications. | Cum | 5926.0 | 5926.0 | 3.74 | False | None | None | False | None | False | 22163.24 | 0 | 2498507 | 75750 | None | code58 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 266.0 | 266.0 | 71.09 | False | None | None | False | None | False | 18909.94 | 0 | 2498508 | 75750 | None | code59 | Form work fo foundation at 8 percent | Cum | 499.84 | 499.84 | 4.1 | False | None | None | False | None | False | 2049.344 | 0 | 2498509 | 75750 | None | code60 | Form work for columns at 70 percent | Cum | 4790.1 | 4790.1 | 1.76 | False | None | None | False | None | False | 8430.576 | 0 | 2498510 | 75750 | None | code61 | Form work for-Beams at 60 percent | Cum | 4105.8 | 4105.8 | 1.49 | False | None | None | False | None | False | 6117.642 | 0 | 2498511 | 75750 | None | code62 | Form work-Roof at 50 percent | Cum | 3421.5 | 3421.5 | 4.0 | False | None | None | False | None | False | 13686.0 | 0 | 2498512 | 75750 | None | code63 | Providing and laying in position Reinforced cement concrete of design mix M25 for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) | Cum | 6248.0 | 6248.0 | 4.1 | False | None | None | False | None | False | 25616.8 | 0 | 2498513 | 75750 | None | code64 | Providing and laying in position Reinforced cement concrete of design mix M 25 for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap /basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) | Cum | 6843.0 | 6843.0 | 10.4 | False | None | None | False | None | False | 71167.2 | 0 | 2498514 | 75750 | None | code65 | Providing and constructing precast concrete solid blocks with compressive strength not less than 35kg. per sqm with cement mortar 1:4 masonry (quoin, Jamb, closer blocks) with solid concrete blocks of size 40X20X20 cms conforming to IS.2185/ 1965 in superstructure including cost of materials, labour charges, double scaffolding, curing complete as per specifications. | Sqm | 1310.0 | 1310.0 | 38.12 | False | None | None | False | None | False | 49937.2 | 0 | 2498515 | 75750 | None | code66 | Providing plastering to masonry including providing and removing scaffolding rounding of all corners whenever required, smooth rendering curing etc complete as per specifications with burnt brick masonry plain plastering 12mm thick in CM 1:4 with lime rendering (internal) | Sqm | 312.0 | 312.0 | 37.12 | False | None | None | False | None | False | 11581.44 | 0 | 2498516 | 75750 | None | code67 | Providing plastering to masonry including providing and removing double scaffolding rounding of all corners whenever required smooth rendering curing etc., complete as per specifications with burnt brick masonry plain plastering 20mm thick in CM 1:4 (external) | Sqm | 354.0 | 354.0 | 56.86 | False | None | None | False | None | False | 20128.44 | 0 | 2498517 | 75750 | None | code68 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 127.0 | 127.0 | 34.881 | False | None | None | False | None | False | 4429.887 | 0 | 2498518 | 75750 | None | code69 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied at 1.67 ltr/10 m² over and including priming coat of exterior primer applied at 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions
of Engineer-in-charge. | Sqm | 174.0 | 174.0 | 54.614 | False | None | None | False | None | False | 9502.836 | 0 | 2498519 | 75750 | None | code70 | Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed at 2 litre per 50 kg of cement or as per direction of Engineer incharge. | Sqm | 800.0 | 800.0 | 9.9 | False | None | None | False | None | False | 7920.0 | 0 | 2498520 | 75750 | None | code71 | Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08percentage and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser, treads of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints as per direction of Engineer in charge. | Sqm | 1173.0 | 1173.0 | 10.0 | False | None | None | False | None | False | 11730.0 | 0 | 2498521 | 75750 | None | code72 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top,
bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-incharge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion : Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) including cost of materials, labour, usage charges of machinery
complete as per specifications. | Kg | 452.0 | 452.0 | 220.0 | False | None | None | False | None | False | 99440.0 | 0 | 2498522 | 75750 | None | code73 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/ m²) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 988.0 | 988.0 | 2.52 | False | None | None | False | None | False | 2489.76 | 0 | 2498523 | 75750 | None | code74 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 8 mm thickness (weight not less than 20 kg/ m²) including cost of materials, labour, usage charges of machinery complete as per specifications. | Sqm | 1305.0 | 1305.0 | 9.45 | False | None | None | False | None | False | 12332.25 | 0 | 2498524 | 75750 | None | code75 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400percentage and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats at 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer at150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. | Sqm | 817.0 | 817.0 | 11.52 | False | None | None | False | None | False | 9411.84 | 0 | 2498525 | 75750 | None | code76 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. | Sqm | 1449.0 | 1449.0 | 5.4 | False | None | None | False | None | False | 7824.6 | 0 | 2498526 | 75750 | None | code77 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20percentage E.C. / Lindane 20percentage E.C. at 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. | Sqm | 118.0 | 118.0 | 40.36 | False | None | None | False | None | False | 4762.48 | 0 | 2498527 | 75750 | None | code78 | Providing and laying 230 mm thick rubble packing in plinth with approved stone, set in regular lines, hand-packed, filling the interstices with approved small stone chips and sand, consolidating by ramming or compacting with heavy roller after watering, including spreading 12 mm layer of stone grit on top, etc., complete for all building works as per drawings, details and specifications.(Below grade slab of buildings and other structures) | Cum | 2560.0 | 2560.0 | 2.69 | False | None | None | False | None | False | 6886.4 | 0 | 2498528 | 75750 | None | code79 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation.Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr at Lumen Maintenance of 70percentage, maximum light intensity should be between 60 degrees to 70 degrees. CCT greater than 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location wit minimized minimal tools. LED Light fixture with 200 W System Power consumption. LED Efficiencygreater than1301m/w, nominal CRI greater than75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved/ Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned.LED Streetlight 200 W | Nos | 18581.0 | 18581.0 | 11.0 | False | None | None | False | None | False | 204391.0 | 0 | 2498529 | 75750 | None | code80 | Supplying and Fixing 40 mm dia class A GI pipe bracket upto 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/tubular pole, using suitable clA, bolts, nuts and wiring using suitable capacity wires. | Each | 1478.0 | 1478.0 | 11.0 | False | None | None | False | None | False | 16258.0 | 0 | 2498530 | 75750 | None | code81 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, and 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system and as per technical data approved. (48" Sweep (1200mm) | Nos | 2984.0 | 2984.0 | 2.0 | False | None | None | False | None | False | 5968.0 | 0 | 2498531 | 75750 | None | code82 | Supply of Automatic Street Light Control System with Optical Micro Sensor, Low voltage / High voltage trip and reset, operating voltage 150 - 280V AC, 50 HZ with suitable SMC enclosure of IP 54 protection, MCBs and contactor suitable to control the load of ...... of single-phase load with necessary clamping arrangements. Makes: As per list of recommended brands-3 KW | Nos | 12430.0 | 12430.0 | 1.0 | False | None | None | False | None | False | 12430.0 | 0 | 2498532 | 75750 | None | code83 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip
thickness and resistivity as per IS-3975 25 Sqmm, 3.5 Core, (12 GI Strips - 4 x 0.8 mm) | Km | 139549.0 | 139549.0 | 0.4 | False | None | None | False | None | False | 55819.6 | 0 | 2498533 | 75750 | None | code84 | GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long,
3.2 mm thick with bolt, nut, GI Strips and washer completeMinimum Weight of GI Pipe: 7.3 Kg | Nos | 743.0 | 743.0 | 4.0 | False | None | None | False | None | False | 2972.0 | 0 | 2498534 | 75750 | None | code85 | Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg each | Nos | 676.0 | 676.0 | 4.0 | False | None | None | False | None | False | 2704.0 | 0 | 2498535 | 75750 | None | code86 | Good Quality Salt for grounding purposes packed in 50 Kg gunny bag | Bag | 310.0 | 310.0 | 4.0 | False | None | None | False | None | False | 1240.0 | 0 | 2498536 | 75750 | None | code87 | Rod Earthing: Rod type of earthing using 40 mm Dia, 3 Mtr long MS rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal & connected to equipment ground terminal using PVC Al wire as specified | Nos | 2172.0 | 2172.0 | 4.0 | False | None | None | False | None | False | 8688.0 | 0 | 2498537 | 75750 | None | code88 | 5 Bentonite clay slurry for earthing in 50 Kg Bag | Bag | 368.0 | 368.0 | 4.0 | False | None | None | False | None | False | 1472.0 | 0 | 2498538 | 75750 | None | code89 | Supplying of 1 x 4 feet -PVC Batten with integrated LED tube 40 W with high quality diffuser with Life of 25000 burning hours & 70percentage lumen maintenance with CRI greater than 80. Power Input: 220-240Vat 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. 11.3.3 LED light fitting 1 x 4 feet - 36/40 W | Nos | 1269.0 | 1269.0 | 2.0 | False | None | None | False | None | False | 2538.0 | 0 | 2498539 | 75750 | None | code90 | Fixing all types and all capacities of 1x4 / 2x2 LED Light fittings indoor on the wall / ceiling / rafters / girders with necessary supporting frame, using 310.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA. | Each | 490.0 | 490.0 | 2.0 | False | None | None | False | None | False | 980.0 | 0 | 2498540 | 75750 | None | code91 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing S hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. | Nos | 171.0 | 171.0 | 2.0 | False | None | None | False | None | False | 342.0 | 0 | 2498541 | 75750 | None | code92 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCBs single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. -SIngle door 8 Way SP & N | Nos | 1492.0 | 1492.0 | 3.0 | False | None | None | False | None | False | 4476.0 | 0 | 2498542 | 75750 | None | code93 | Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC61439-3 and IK 09 tested as perIS/IEC62262 with minimum IP43 protection provided with Polyurethane (PUR)gasket, with suitable earthing system, onwall/ wood board/ flush mounting using required clA, bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3phase Double door with necessary busbar completely wired to use on 440V 3phase 4wire powder coated painting etc.,complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 -4-Way DB | Nos | 10329.0 | 10329.0 | 2.0 | False | None | None | False | None | False | 20658.0 | 0 | 2498543 | 75750 | None | code94 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts,nuts,necessary phase separators,handle and wiring complete.Protection of Overload and Short circuit with adjustable thermal magnetic release, Microprocessor releases hall have Earth Fault asperIS/IEC60947-2.(Icu=100percentagelcs).In 4P MCCB,all Poles should haveprotection forShort-Cicrcuit/ Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with livecurrent carrying path with the front cover open).Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism..4P 100 A 25 kA, MCCB (Incomer) | Nos | 8487.0 | 8487.0 | 2.0 | False | None | None | False | None | False | 16974.0 | 0 | 2498544 | 75750 | None | code95 | Supplying,fixing andwiring Residual current circuit breaker(RCCB)240/450V upto 300mA sensitivity on existing wood/ panel board.-32-40A 2 pole | Nos | 4831.0 | 4831.0 | 5.0 | False | None | None | False | None | False | 24155.0 | 0 | 2498545 | 75750 | None | code96 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with
Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.-6-32 A SP | Nos | 415.0 | 415.0 | 5.0 | False | None | None | False | None | False | 2075.0 | 0 | 2498546 | 75750 | None | code97 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C Type curve, indicator ON/OFF, energy cross-3 with
Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.- 6-32 A TPN | Nos | 1717.0 | 1717.0 | 5.0 | False | None | None | False | None | False | 8585.0 | 0 | 2498547 | 75750 | None | code98 | Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 40 mm dia 2.5 mm thick | Rmtr | 149.0 | 149.0 | 113.0 | False | None | None | False | None | False | 16837.0 | 0 | 2498548 | 75750 | None | code99 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.-4-5 Way | Each | 137.0 | 137.0 | 5.0 | False | None | None | False | None | False | 685.0 | 0 | 2498549 | 75750 | None | code100 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.-6 Module | Each | 234.0 | 234.0 | 5.0 | False | None | None | False | None | False | 1170.0 | 0 | 2498550 | 75750 | None | code101 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.-6A One Way Switch | Each | 102.0 | 102.0 | 10.0 | False | None | None | False | None | False | 1020.0 | 0 | 2498551 | 75750 | None | code102 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.-2.5 mm2 | Rmtr | 42.0 | 42.0 | 100.0 | False | None | None | False | None | False | 4200.0 | 0 | 2498552 | 75750 | None | code103 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. For earthing-1.5mm2 | Rmtr | 26.0 | 26.0 | 100.0 | False | None | None | False | None | False | 2600.0 | 0 | 2498553 | 75750 | None | code104 | Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete.upto 50 mm conduit CC floor | Rmtr | 69.0 | 69.0 | 130.0 | False | None | None | False | None | False | 8970.0 | 0 | 2498554 | 75750 | None | code105 | Supplying and fixing PVC/metal conduit Deep junction box 19/20 mm deep Junction box | Nos | 49.0 | 49.0 | 5.0 | False | None | None | False | None | False | 245.0 | 0 | 2498555 | 75750 | None | code106 | Point wiring using Copper wire without switch. supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on theexisting plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Short point upto 3m from tapping point to out let via switch box | Point | 285.0 | 285.0 | 2.0 | False | None | None | False | None | False | 570.0 | 0 | 2498556 | 75750 | None | code107 | Point wiring using Copper wire without switch. supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on theexisting plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Medium point above 3m upto 6m from tapping point to out let
via switch box | Nos | 394.0 | 394.0 | 5.0 | False | None | None | False | None | False | 1970.0 | 0 | 2498557 | 75750 | None | code108 | Point wiring using Copper wire without switch. supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on theexisting plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet Long point above 6m upto 10m from tapping point to out let viaswitch box | Nos | 570.0 | 570.0 | 5.0 | False | None | None | False | None | False | 2850.0 | 0 | 2498558 | 75750 | None | code109 | providing L shape MS Armature angle of 56feetx5feet and M.S. framing with black colour and MS pillar work for the support of BWSSB signage lightning board size 56 feet x 4 feet, providing and fixing of BWSSB English letters with GI material and acrylic cap size: 28 feet x 4 feet-2 Nos Boards with accessories at top of the | Nos | 499000.0 | 499000.0 | 1.0 | False | None | None | False | None | False | 499000.0 | 0 | 2498559 | 75750 | None | code110 | Rammurthy nagar GLR to Kalkere-Demolishing cement concrete manually/ by mechanical means including disposal of material to the appropriate disposal area as per direction of Engineer-in-charge. | Cum | 1663.0 | 1663.0 | 0.5 | False | None | None | False | None | False | 831.5 | 0 | 2498560 | 75750 | None | code111 | Supply, delivery at site, erection, testing and commissioning of brand new best efficient, axial tubular(Tube installed) Non clog submersible pump of required voltage supply frequency 50Hz submersible motor, standard control panel, submersible cable, lifting chain with all its accessories. 4240m3/hr at 3m head. | Nos | 2664825.0 | 2664825.0 | 2.0 | False | None | None | False | None | False | 5329650.0 | 0 | 2498561 | 75750 | None | code112 | Supply and fixing of ductile iron double flanged swing check vavles with slanted seat or with lever weight with straight disc, with metallic corrosion proof and wear resistant seat faces with nickel overlay micro - finished/ Integral seat with body and disc in Ductile Iron in GGG 40/50 shaft of stainless steel and bearings of zinc free bronze and surface protection with epoxy liquid of GSK quality-For PN 16.0-900mm dia | Nos. | 2150202.0 | 2150202.0 | 2.0 | False | None | None | False | None | False | 4300404.0 | 0 | 2498562 | 75750 | None | code113 | Supplying and fixing of Double Flanged Resilient seated short body Butterfly valves of various dia as per IS 13095/EN 593 with integral DI seat face with approved soft sealing with body and disc of ductile iron (DI) of grade GGG-40/50, Body seat & Seal retaining ring of SS 304/ CF8, Shaft of stainless steel AISI 410/420/431, Bronze shaft bearing, periferal disk, seal end O rings of EPDM, double eccentric disk. Body
and disk should be coated with electrostatcially applied epoxy powder coating with a coating thickness of 250 micron both inside and out side. The rate is inclusive of cost of valve, TP set, galvanised bolts and nuts and rubber insertions. (All the drilled holes in the body shall be of through holes, no tapped holes will be allowed.)-For Valve of PN 16.0 and 900mm | No. | 211932.0 | 211932.0 | 2.0 | False | None | None | False | None | False | 423864.0 | 0 | 2498563 | 75750 | None | code114 | Supply, installation, testing & commissioning of flange ends Expansion Bellow as per EJMA standards of overall length of minimum 300 mm, designed for 15 mm axial compression and 5 mm axial extension with tie rods etc. of following MOC & pressure
ratings. MOC: Bellows: SA 240 Gr. 304; Internal Sleeve: SA 240 Gr. 304; Weldends: IS 2062 Gr. B; Flanges: IS 2062 Gr. B (Drilling as per IS 1538 / IS 6392 ) & Limit Rods & Nuts: CS - IS 1367.-NB 900 mm, PN - 1.6 | No | 57216.0 | 57216.0 | 2.0 | False | None | None | False | None | False | 114432.0 | 0 | 2498564 | 75750 | None | code115 | Manufacturing, providing, transporting, rolling, lowering, laying, jointing & testing and commissioning of MS specials of minimum 8mm thick such as bends, tail pieces, reduces etc. conforming to IS-7322:1985 with latest amendments and including perfect linking and welding of joints to correct position includng cost and conveyance of materials with all lead and lifts, cost all labour and giving satisfactory hydraulic test as per IS:3589:2001 with latest amendments for test pressure and working pressure both at factory and site etc. complete as per detailed specifications with inside lining two coat of food grade epoxy painting of approved make with each coat of 250 micron thick (after dry) over one coat of food grade epoxy primer of approved make with minium of 50 micron thick (after dry) and outside 25mm thick coating in CM 1:3 by providing 50x50mm weld mesh including loading and unloading of the pipes for the following category to suit PSC / MS / CI / AC / DI / PVC pipes. The weight of MS shell only by considered before lining and coating for arriving at the rate. The thickness of plate will be specified by the engineer. Contractor will make his own arrangements for procuring water for testing) for:Note: 1) For small works where the C.M. lining is not practicable for inside surface of the pipe, food grade expoxy painting of two coat over one coat of epoxy primer may be proposed and got approved. 2) The above rates are applicable only for pipe works.Pipe bends,branches, tail pieces, reducers etc. for above 500mm dia pipes | Kg | 155.0 | 155.0 | 3000.0 | False | None | None | False | None | False | 465000.0 | 0 | 2498565 | 75750 | None | code116 | Supply, Installation, Commissioning and Testing (for receipt of readings to the Central Server at Cauvery Bhavan) of GPRS + GSM based Multi Track Ultrasonic Bulk Flow Meters to the inlet, outlet, feeder mains and distribution branches ranging from 450mm to 1800mm. The flow meter shall be installed using hot tapping method and existing water supply lines. The data shall by synchronized to existing software. The Ultrasonic
Bulk Meters shall comply with the specificationsFor Multi Track Ultrasonic Bulk Flow Meters, sensors, transmitter, panels
etc. for 1000 / 1100mm dia. | Nos | 523075.0 | 523075.0 | 1.0 | False | None | None | False | None | False | 523075.0 | 0 | 2498566 | 75750 | None | code117 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications,including setting out, shoring, strutting, barricading, caution lights,including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in aradius of 50 m and lift upto 1.5 m including cost of labour, tools, usageof machinery & other appurtenaces required to complete the work
In all kinds of soils Depth upto 3 m | Cum | 102.0 | 102.0 | 568.88 | False | None | None | False | None | False | 58025.76 | 0 | 2498567 | 75750 | None | code118 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing,
and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) (Valve chambers/Butterfly Valve/Flow meter chamber/thrust block) | Cum | 6217.0 | 6217.0 | 7.41 | False | None | None | False | None | False | 46067.97 | 0 | 2498568 | 75750 | None | code119 | Providing and laying in position Cement Concrete for all Foundation works.
The granite/trap/basalt crushed graded coarse aggregates and fine aggregates
as per relevant IS Codes machine mixed with super plasticizers laid in finished
layers, well compacted using needle vibrators, including all lead & lifts, cost
of all materials, quality confirming to the requirements of relevant IS codes,
labour, Usage charges of machinery, curing and all the other appurtenances
required to complete the work as per technical specifications.-M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-(Valve chambers/Butterfly Valve/Flow meter chamber/thrust block) | Cum | 6499.0 | 6499.0 | 45.1 | False | None | None | False | None | False | 293104.9 | 0 | 2498569 | 75750 | None | code120 | Formwork at 3percentage for foundations | Cum | 194.97 | 194.97 | 0.45 | False | None | None | False | None | False | 87.7365 | 0 | 2498570 | 75750 | None | code121 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all
lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6605.0 | 6605.0 | 36.0 | False | None | None | False | None | False | 237780.0 | 0 | 2498571 | 75750 | None | code122 | Formwork at 10percentage for retaining structures | Cum | 660.5 | 660.5 | 3.6 | False | None | None | False | None | False | 2377.8 | 0 | 2498572 | 75750 | None | code123 | Providing and laying in position Reinforced cement concrete M30 Design Mix for top cover flat slab. The Granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes with plastering and smooth finishing in cement mortar 1:3, 12 mm thick for inside surface, labour,centering, scaffolding, strutting, plywood/ steel form work , Usage charges of machinery, curing and all other appurtenances required to complete the work as per design and technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately). (Minimum cement content: 360 kgs (7.20 bags))-Valve chambers/Butterfly Valve/Flow meter chamber | Cum | 13433.0 | 13433.0 | 7.35 | False | None | None | False | None | False | 98732.55 | 0 | 2498573 | 75750 | None | code124 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and
technical specification-For valve chambers | Kg | 79.01 | 79.01 | 8109.99 | False | None | None | False | None | False | 640770.3099 | 0 | 2498574 | 75750 | None | code125 | Supplying of on load change over switches 4poles ,AC-23ADuty,415V,50Hz,AC Supply.With all accessories.(SMEnclosureSheet Metal Execution)- 125 A | Nos. | 12324.0 | 12324.0 | 1.0 | False | None | None | False | None | False | 12324.0 | 0 | 2498575 | 75750 | None | code126 | 1.1 kV Class Armoured Aluminium Cable with glands/lugs/ferrules-4C x 95 Sq mm | Rmtr | 762.0 | 762.0 | 64.0 | False | None | None | False | None | False | 48768.0 | 0 | 2498576 | 75750 | None | code127 | supply,Transportation, Installation, Testing and Commissioning of 11/0.433 KV TRANSFORMER with all test reports. The Transformer shall be designed and manufactured as per Energy Efficiency Level-2 at basic Insulation level conforming to ISS 2026 (Part ItoPart-II) with latest amended and as per IS 1180 Part-I : 2014 latest amended, OCTC with initial filling of oil as per IS 335-1993. The basic details of the Transformer are as under.1. Quantity : 1 2. Rated KVA: KVA 3. Service & Location: Continuous Outdoor Distribution Transformer 4. Mounting: Plinth. 5. Wound: Copper Double wound 6. Type: Core type oil immersed 7. Cooling: ONAN 8. Temp Rise: 40 C in oil, 45 degree C by resistance 9. Vector Group, Dyn 11 10. Primary Connection: Delta 11. Nominal Voltage / Current: 12. Highest system Voltage: 12000V 13. Primary Frequency :50 HZ plus or minus 3percentage 14. Number of Phases: 3 15. Primary wires: 3 16. Secondary connection: Star 17. Secondary Volts / Current : 433V 18. Secondary phases: 3 19. Secondary wires: 4 20. Taps on primary winding for primary voltage variation: plus5percentage to - 10percentage in steps of 2.5percentage of 7 position (6 Steps) 21. Terminal arrangement. a. HV: HT terminal box as per the site condition. b. LV: Cable box suitable to receive -Sq.mm XLPE cable 22. LV: One separate terminal for earthing. 23. Total Losses at 50percentage Loading [Watts] [Max] - as per IS 24. Total Losses at 100percentage Loading [Watts] [Max]- as per IS 25.Percentage Impedance at 75 deg. C at -as per IS 26. No Load current: Less than 2percentage of full load current. 27. Standard Fittings & Accessories. a. Rating and terminal marking plate: One b. Lifting Lugs: Two c. Off-circuit tap switch: One. d. Earthing Terminals : Two e. Radiators (Attachable): Adequate f. Explosion vent with Diaphragm : One g. Conservator with Drain plug: one h. Oil filling hole with cap :One i. Oil level indicator: Onej. Dehydrating Silica gel Breather: One k. Terminal Arrangement: HV With Terminal Box
l. Terminal Arrangement: LV Cable Box m. Separate Neutral Bushing : One n. Drain cum filter valve with blanking plate: One o. Air release device: One, p. Thermometer Pocket: One q. Four: Unidirectional flat rollers r. One :10Cm dial thermometer (Rigid stem type)-160 KVA Copper Wound Transformer | No. | 717255.0 | 717255.0 | 1.0 | False | None | None | False | None | False | 717255.0 | 0 | 2498577 | 75750 | None | code128 | Heat Shrinkable Indoor Type Cable Termination Kit for XLPE Cable | No | 4816.0 | 4816.0 | 1.0 | False | None | None | False | None | False | 4816.0 | 0 | 2498578 | 75750 | None | code129 | Heat Shrinkable Outdoor Type Cable Termination Kit for XLPE Cable | No | 4428.0 | 4428.0 | 1.0 | False | None | None | False | None | False | 4428.0 | 0 | 2498579 | 75750 | None | code130 | Heat shrinkable Type Terminations LT UG Cable | No | 333.0 | 333.0 | 2.0 | False | None | None | False | None | False | 666.0 | 0 | 2498580 | 75750 | None | code131 | Cable covering tiles 250x125x40 mm (Qty=4000 No.. per km) | No. | 8.48 | 8.48 | 1.0 | False | None | None | False | None | False | 8.48 | 0 | 2498581 | 75750 | None | code132 | Route and Joint Indicating Stones (Qty=20 No.. per km) | No. | 110.24 | 110.24 | 5.0 | False | None | None | False | None | False | 551.2 | 0 | 2498582 | 75750 | None | code133 | Transformer Structure Kit with Three H Frames without tranformer seating and seating Angle support cross arm for 63/100/250/500kVA (UG Cable) MS | Per Structure | 21310.1 | 21310.1 | 1.0 | False | None | None | False | None | False | 21310.1 | 0 | 2498583 | 75750 | None | code134 | 11kV Lightning Arrestor, Metal oxide, 9kV, 5kA ceramic type with ground disconnector | Set | 1562.13 | 1562.13 | 1.0 | False | None | None | False | None | False | 1562.13 | 0 | 2498584 | 75750 | None | code135 | 11kV,45KN Disc Insulator, porcelain | Set | 398.56 | 398.56 | 2.0 | False | None | None | False | None | False | 797.12 | 0 | 2498585 | 75750 | None | code136 | HT Top support with bolts, nuts & washers | Set | 202.26 | 202.26 | 2.0 | False | None | None | False | None | False | 404.52 | 0 | 2498586 | 75750 | None | code137 | Alkathene Tube 19mm dia and in coils of 30Mtrs. | No. | 427.39 | 427.39 | 1.0 | False | None | None | False | None | False | 427.39 | 0 | 2498587 | 75750 | None | code138 | 11kV, 200A single break GOS | Set | 8543.0 | 8543.0 | 1.0 | False | None | None | False | None | False | 8543.0 | 0 | 2498588 | 75750 | None | code139 | 11kV Soild core type HG fuse Unit | Set | 1053.14 | 1053.14 | 1.0 | False | None | None | False | None | False | 1053.14 | 0 | 2498589 | 75750 | None | code140 | Rabbit ACSR Conductor | Mtr | 52.16 | 52.16 | 200.0 | False | None | None | False | None | False | 10432.0 | 0 | 2498590 | 75750 | None | code141 | Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work- In all kinds of soils. Depth upto 1.50m | Cum | 484.0 | 484.0 | 37.5 | False | None | None | False | None | False | 18150.0 | 0 | 2498591 | 75750 | None | code142 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath
Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip
thickness and resistivity as per IS-3975-300 Sqmm, 3.5 Core, (32 GI Strips - 4 x 0.8 mm) | Rmtr | 1066.01 | 1066.01 | 100.0 | False | None | None | False | None | False | 106601.0 | 0 | 2498592 | 75750 | None | code143 | 95 Sqmm, 3.5 Core, (21 GI Strips - 4 x 0.8 mm) | Rmtr | 373.21 | 373.21 | 35.0 | False | None | None | False | None | False | 13062.35 | 0 | 2498593 | 75750 | None | code144 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff- 35 to 95 Sqmm | Rmtr | 31.14 | 31.14 | 25.0 | False | None | None | False | None | False | 778.5 | 0 | 2498594 | 75750 | None | code145 | 120 to 240 Sqmm | Rmtr | 32.28 | 32.28 | 25.0 | False | None | None | False | None | False | 807.0 | 0 | 2498595 | 75750 | None | code146 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100percentage lcs). In 4P MCCB, all Poles should have protection for Short- icrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.- Four pole-320-400 A 50 kA | Nos | 30111.0 | 30111.0 | 1.0 | False | None | None | False | None | False | 30111.0 | 0 | 2498596 | 75750 | None | code147 | 160 A 25 kA | Nos | 13447.0 | 13447.0 | 2.0 | False | None | None | False | None | False | 26894.0 | 0 | 2498597 | 75750 | None | code148 | Supply and delivery of floor mounted type FCMA Air/ Oil Cooled soft starter suitable for the LT motor offered for operation in AC three Phase 50Hz (+/- 5percentage), 415V(+/-10percentage) including line contactors suitable for next standard higher KW rating, Over load relay, instrument panel with frequency meter, Ammeter, Voltmeter, indicating lamp 6Nos, LED ON/OFF type and Start /Stop push button.- | Nos | 366112.0 | 366112.0 | 2.0 | False | None | None | False | None | False | 732224.0 | 0 | 2498598 | 75750 | None | code149 | Supplying and fixing of LED type panel board indicating
lamp with required colour suitable for 230/440VAC. 50 Hz
12/24V D.C.-On/OFF/TRIP/R/Y/B indicators | Nos | 515.0 | 515.0 | 6.0 | False | None | None | False | None | False | 3090.0 | 0 | 2498599 | 75750 | None | code150 | Supplying, fixing and wiring 50/5 to 400/5A 5VA burden Current Transformer Class 0.5 accuracy with Tape Wound. | Nos | 562.0 | 562.0 | 3.0 | False | None | None | False | None | False | 1686.0 | 0 | 2498600 | 75750 | None | code151 | Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, kVA, kWH, kVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy | Nos | 9315.0 | 9315.0 | 1.0 | False | None | None | False | None | False | 9315.0 | 0 | 2498601 | 75750 | None | code152 | Supplying, fixing and wiring 3 Phase Digital Ammeter / Voltmeter | Nos | 1425.0 | 1425.0 | 2.0 | False | None | None | False | None | False | 2850.0 | 0 | 2498602 | 75750 | None | code153 | Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia. | Nos | 3750.0 | 3750.0 | 5.0 | False | None | None | False | None | False | 18750.0 | 0 | 2498603 | 75750 | None | code154 | Supplying and running of GI strips for grounding connections, using necessary fixing materials as required.-50 x 6 mm GI (MCC Panels, Main Motors etc.) | Rmtr | 218.0 | 218.0 | 20.0 | False | None | None | False | None | False | 4360.0 | 0 | 2498604 | 75750 | None | code155 | 65 x 10 mm GI (Trf. Body, neutral, Main Earth Grid etc.) | Rmtr | 975.0 | 975.0 | 20.0 | False | None | None | False | None | False | 19500.0 | 0 | 2498605 | 75750 | None | code156 | The cost for fabrication panel, Copper busbars, interconnecting cables,mounting fasterners, terminal box etc. Installation, Commissioning and transportation | Job | 240000.0 | 240000.0 | 1.0 | False | None | None | False | None | False | 240000.0 | 0 | 2498606 | 75750 | None | code157 | Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 113.0 | 113.0 | 1120.0 | False | None | None | False | None | False | 126560.0 | 0 | 2498607 | 75750 | None | code158 | Providing and fixing 6mm Clear/opal white/solar bronze/blue/green tinted Multi wall poly carbonate sheet for Tubular structure. The work including cost of all materials, labour charges, and hire charges of
machinery for cutting, welding, grinding and erection equipments, with all lead and lifts, transportation, loading and unloading and all other incidental charges etc. complete as per specification and directions of the engineer in charge of the work. | Sqmm | 127.0 | 127.0 | 16.0 | False | None | None | False | None | False | 2032.0 | 0 | 2498608 | 75750 | None | code159 | 2mmthickperforatedcableGItraywithonexistingMSanglesupportusing necessary GI bolts/nuts and washer or welding as required. | Rmtr | 587.0 | 587.0 | 150.0 | False | None | None | False | None | False | 88050.0 | 0 | 2498609 | 75750 | None | code160 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975-16 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm) | Rmtr | 141.84 | 141.84 | 150.0 | False | None | None | False | None | False | 21276.0 | 0 | 2498610 | 75750 | None | code161 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff-2.5 to 25 Sqmm | Rmtr | 20.89 | 20.89 | 150.0 | False | None | None | False | None | False | 3133.5 | 0 |
|