tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1706794059000 | 1 | None | None | Buildings | Civil works | 4360696.29 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2387513 | 71019 | None | PWD Volume-2 SR2021-22 Page No 187 Item 19.2.1 | Demolishing cement concrete manually/ by mechanical means including disposal of material to the appropriate disposal area as per direction of Engineer-in-charge.Terrace WPC ---- complete as per Specification and as directed by the Engineer in-charge of work | Cum | 2060.45 | 2060.45 | 191.21 | False | None | None | False | None | False | 393978.6445 | 0 | 2387514 | 71019 | None | PWD Volume-1 SR2021-22 Page No 15 Item 2.1.4 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates ---- complete as per Specification and as directed by the Engineer in-charge of work | Cum | 7702.86 | 7702.86 | 143.4 | False | None | None | False | None | False | 1104590.124 | 0 | 2387515 | 71019 | None | PWD Volume-2 SR2021-22 Page No 149 Item 15.1 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation,
making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. ---- complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 1012.26 | 1012.26 | 1912.075 | False | None | None | False | None | False | 1935517.0395 | 0 | 2387516 | 71019 | None | PWD Volume-2 SR2021-22 Page No 41 Item 8.2.2 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Rough Plastering For Dadooing works ---- complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 345.68 | 345.68 | 63.36 | False | None | None | False | None | False | 21902.2848 | 0 | 2387517 | 71019 | None | PWD Volume-2 SR2021-22 Page No 65 Item 9.38 | Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.patches ---- complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 1724.68 | 1724.68 | 63.36 | False | None | None | False | None | False | 109275.7248 | 0 | 2387518 | 71019 | None | PWD Volume-2 SR2021-22 Page No 101 Item13.13.1 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- complete as per Specification and as directed by the Engineer in-charge of work | Cum | 122431.78 | 122431.78 | 1.755 | False | None | None | False | None | False | 214867.7739 | 0 | 2387519 | 71019 | None | PWD Volume-2 SR2021-22 Page No 188 Item19.14.1 | Dismantling wood work in frames, trusses, purlins and rafters upto 10 metres span and 5 metres height including stacking to the appropriate disposal area as per direction of Engineer-in-charge.
sectional area 40 square centimeters and above ---- complete as per Specification and as directed by the Engineer in-charge of work | Cum | 3604.25 | 3604.25 | 2.34 | False | None | None | False | None | False | 8433.945 | 0 | 2387520 | 71019 | None | PWD Volume-2 SR2021-22 Page No 105 Item12.57.6 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial ---- complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 4115.96 | 4115.96 | 57.6 | False | None | None | False | None | False | 237079.296 | 0 | 2387521 | 71019 | None | PWD Volume-2 SR2021-22 Page No 105 Item12.51 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- complete as per Specification and as directed by the Engineer in-charge of work | Nos | 1258.82 | 1258.82 | 24.0 | False | None | None | False | None | False | 30211.68 | 0 | 2387522 | 71019 | None | PWD Volume-2 SR2021-22 Page No 105 Item12.58 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. ---- complete as per Specification and as directed by the Engineer in-charge of work | Nos | 148.68 | 148.68 | 28.0 | False | None | None | False | None | False | 4163.04 | 0 | 2387523 | 71019 | None | PWD Volume-2 SR2021-22 Page No 105 Item12.62 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete ---- complete as per Specification and as directed by the Engineer in-charge of work | Nos | 293.64 | 293.64 | 56.0 | False | None | None | False | None | False | 16443.84 | 0 | 2387524 | 71019 | None | PWD Volume-2 SR2021-22 Page No 105 Item12.63 | Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete ---- complete as per Specification and as directed by the Engineer in-charge of work | Nos | 161.07 | 161.07 | 56.0 | False | None | None | False | None | False | 9019.92 | 0 | 2387525 | 71019 | None | PWD Volume-2 SR2021-22 Page No 107 Item12.75.1 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete :125x85x5.5 mm (heavy type) ---- complete as per Specification and as directed by the Engineer in-charge of work | Nos | 340.72 | 340.72 | 112.0 | False | None | None | False | None | False | 38160.64 | 0 | 2387526 | 71019 | None | PWD Volume-2 SR2021-22 Page No 69 Item10.6.3 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm ---- complete as per Specification and as directed by the Engineer in-charge of work | Nos | 74.34 | 74.34 | 168.0 | False | None | None | False | None | False | 12489.12 | 0 | 2387527 | 71019 | None | PWD Volume-2 SR2021-22 Page No 41 Item 8.1.1 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement:4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.ceiling plaster ---- complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 315.94 | 315.94 | 160.0 | False | None | None | False | None | False | 50550.4 | 0 | 2387528 | 71019 | None | PWD Volume-2 SR2021-22 Page No 43 Item 8.12 | Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineering- inCharge.ceiling plaster1kg compound for 1 sqm area ---- complete as per Specification and as directed by the Engineer in-charge of work | Kg | 79.29 | 79.29 | 160.0 | False | None | None | False | None | False | 12686.4 | 0 | 2387529 | 71019 | None | PWD Volume-2 SR2021-22 Page No 50 Item 8.54.2 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge.GROUND FLOORfor patches ---- complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 136.29 | 136.29 | 606.4 | False | None | None | False | None | False | 82646.256 | 0 | 2387530 | 71019 | None | PWD Volume-2 SR2021-22 Page No 81 Item 11.16.2 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- complete as per Specification and as directed by the Engineer in-charge of work | Kgs | 182.13 | 182.13 | 432.0 | False | None | None | False | None | False | 78680.16 | 0 |
| 1706794059000 | 0 | None | None | Buildings | Plumbing and sanitation | 213284.36 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2387531 | 71020 | None | PWD Volume-2 SR2023-24 Page No 131 Item 14.3.1 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :
W.C. pan with ISI marked white solid plastic seat and lid ---- complete as per Specification and as directed by the Engineer in-charge of work | Each | 7405.5 | 7405.5 | 4.0 | False | None | None | False | None | False | 29622.0 | 0 | 2387532 | 71020 | None | PWD Volume-2 SR2023-24 Page No 125 Item 14.7.4 | White Vitreous China Flat back wash basin size 550x 400 mm
with single 15 mm C.P. brass pillar tap ---- complete as per Specification and as directed by the Engineer in-charge of work | Each | 2905.45 | 2905.45 | 2.0 | False | None | None | False | None | False | 5810.9 | 0 | 2387533 | 71020 | None | PWD Volume-2 SR2023-24 Page No 126Item 14.28.2.2 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.40mm dia pipes, From wash basin waste lines ---- complete as per Specification and as directed by the Engineer in-charge of work | m | 113.99 | 113.99 | 2.0 | False | None | None | False | None | False | 227.98 | 0 | 2387534 | 71020 | None | PWD Volume-5 SR2023-24 Page No 113 Item 10.1.5 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest
amendments and conveying to worksite, rolling and lowering into
trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: PVC pipe - OD 75mm and 6 Kg/sqcm, waste linesInternal wall ---- complete as per Specification and as directed by the Engineer in-charge of work | m | 272.58 | 272.58 | 6.0 | False | None | None | False | None | False | 1635.48 | 0 | 2387535 | 71020 | None | PWD Volume-5 SR2023-24 Page No 122 Item 10.1.7 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest
amendments and conveying to worksite, rolling and lowering into
trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete PVC pipe - OD 110mm and 6 Kg/sqcm, sanitary linesInternal wall ---- complete as per Specification and as directed by the Engineer in-charge of work | m | 509.23 | 509.23 | 120.0 | False | None | None | False | None | False | 61107.6 | 0 | 2387536 | 71020 | None | PWD Volume-2 SR2023-24 Page No 122 Item 13.31.2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 20 mm nominal dia pipes ---- complete as per Specification and as directed by the Engineer in-charge of work | m | 299.84 | 299.84 | 150.0 | False | None | None | False | None | False | 44976.0 | 0 | 2387537 | 71020 | None | PWD Volume-2 SR2023-24 Page No 126 Item 13.53 | Constructing brick masonry chamber for underground C.I. inspection
chamber and bends with bricks in cement mortar 1:4 (1 cement : 4
coarse sand) C.I. cover with frame (light duty) 455x610 mm internal
dimensions, total weight of cover with frame to be not less than 38
kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size), inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5 ---- complete as per Specification and as directed by the Engineer in-charge of work | Nos | 6990.44 | 6990.44 | 10.0 | False | None | None | False | None | False | 69904.4 | 0 |
| 1706794059000 | 0 | None | None | Buildings | internal electrification | 57399.92 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2387538 | 71021 | None | It No-1.1.1 | Supplying heavy gauge PVC conduit pipe …….dia .......mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.20mm dia 2mm thick ---- complete as per Specification and as directed by the Engineer in-charge of work | Mtr | 80.24 | 80.24 | 300.0 | False | None | None | False | None | False | 24072.0 | 0 | 2387539 | 71021 | None | It No-3.3.3 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 6Way ---- complete as per Specification and as directed by the Engineer in-charge of work | Each | 175.82 | 175.82 | 2.0 | False | None | None | False | None | False | 351.64 | 0 | 2387540 | 71021 | None | It No-3.5.3 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.(15/16/3.6) 6Moudule ---- complete as per Specification and as directed by the Engineer in-charge of work | Each | 287.92 | 287.92 | 2.0 | False | None | None | False | None | False | 575.84 | 0 | 2387541 | 71021 | None | It No-3.6.1 | Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate.. Is 3854 and IS 1293. (16/3.7) Using Group "A" materials 6Amps one way Switch ---- complete as per Specification and as directed by the Engineer in-charge of work | Each | 103.84 | 103.84 | 4.0 | False | None | None | False | None | False | 415.36 | 0 | 2387542 | 71021 | None | It No-2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge.GROUP -A. - 1.5 sqmm ---- complete as per Specification and as directed by the Engineer in-charge of work | Mtr | 30.68 | 30.68 | 500.0 | False | None | None | False | None | False | 15340.0 | 0 | 2387543 | 71021 | None | It No-11.3.1 | Supplying of 2' feet LED PVC Square Batten ..W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI morethan 80. Power Input: 220-240V @ 50Hz & Power factor morethan 0.9 along with CE approved drivers. 5 years Warranty against any manufacturing defect working under standard electrical condition (25/4.29) LED light fighting 2'- 9/10 watts ---- complete as per Specification and as directed by the Engineer in-charge of work | Each | 585.28 | 585.28 | 20.0 | False | None | None | False | None | False | 11705.6 | 0 | 2387544 | 71021 | None | It No-13.7.1 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. - On wall / ceiling / Rafter / Girders ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge. ---- complete as per Specification and as directed by the Engineer in-charge of work | Each | 140.42 | 140.42 | 2.0 | False | None | None | False | None | False | 280.84 | 0 | 2387545 | 71021 | None | It No-7.1 | Supplying of Exhaust Fan of 1440 RPM of 300mm (12") size with Bracket, blades complete for Light duty suitable to operate on 230V,50Hz, A.C.,supply ---- complete as per Specification and as directed by the Engineer in-charge of work | No | 1819.56 | 1819.56 | 2.0 | False | None | None | False | None | False | 3639.12 | 0 | 2387546 | 71021 | None | It No-14.12 | Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 amps. ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire. ---- complete as per Specification and as directed by the Engineer in-charge of work | No | 509.76 | 509.76 | 2.0 | False | None | None | False | None | False | 1019.52 | 0 |
| 1706794059000 | 0 | None | None | Buildings | Toilet construction | 339446.8 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2387547 | 71022 | None | PWD Volume-1 SR2023-24 Page No 8Item 1.12 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.In all kinds of soils upto 300 mm depth ---- complete as per Specification and as directed by the Engineer in-charge of work | Cum | 117.7 | 117.7 | 11.25 | False | None | None | False | None | False | 1324.125 | 0 | 2387548 | 71022 | None | PWD Volume-1 SR2023-24 Page No 15 Item 2.1.4 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates ---- complete as per Specification and as directed by the Engineer in-charge of work | Cum | 7702.86 | 7702.86 | 2.56 | False | None | None | False | None | False | 19719.3216 | 0 | 2387549 | 71022 | None | PWD Volume-2 SR2023-24 Page No 9 Item 5.4 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) ---- complete as per Specification and as directed by the Engineer in-charge of work | Cum | 7915.97 | 7915.97 | 8.1 | False | None | None | False | None | False | 64119.357 | 0 | 2387550 | 71022 | None | PWD Volume-2 SR2023-24 Page No 17 Item 6.32 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- complete as per Specification and as directed by the Engineer in-charge of work | Cum | 1623.09 | 1623.09 | 36.0 | False | None | None | False | None | False | 58431.24 | 0 | 2387551 | 71022 | None | PWD Volume-2 SR2023-24 Page No 41 Item 8.1.1 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement:4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 315.94 | 315.94 | 31.68 | False | None | None | False | None | False | 10008.9792 | 0 | 2387552 | 71022 | None | PWD Volume-2 SR2023-24 Page No 41 Item 8.2.2 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 345.68 | 345.68 | 40.512 | False | None | None | False | None | False | 14004.18816 | 0 | 2387553 | 71022 | None | PWD Volume-2 SR2023-24 Page No 65 Item 9.38 | Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 1724.69 | 1724.69 | 31.68 | False | None | None | False | None | False | 54638.1792 | 0 | 2387554 | 71022 | None | PWD Volume-2 SR2023-24 Page No 50 Item 8.54.2 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. ---- complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 136.29 | 136.29 | 40.512 | False | None | None | False | None | False | 5521.38048 | 0 | 2387555 | 71022 | None | PWD Volume-2 SR2023-24 Page No 60 Item 9.11 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. ---- complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 1101.47 | 1101.47 | 5.4 | False | None | None | False | None | False | 5947.938 | 0 | 2387556 | 71022 | None | PWD Volume-2 SR2023-24 Page No 104 Item 12.54 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. ---- complete as per Specification and as directed by the Engineer in-charge of work | m | 394.0 | 394.0 | 20.8 | False | None | None | False | None | False | 8195.2 | 0 | 2387557 | 71022 | None | PWD Volume-2 SR2023-24 Page No 104 Item 12.55.2 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.- with one side prelam ---- complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 2527.56 | 2527.56 | 2.7 | False | None | None | False | None | False | 6824.412 | 0 | 2387558 | 71022 | None | PWD Volume-2 SR2023-24 Page No 81 Item 11.6.2 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- complete as per Specification and as directed by the Engineer in-charge of work | Kgs | 182.13 | 182.13 | 446.4 | False | None | None | False | None | False | 81302.832 | 0 | 2387559 | 71022 | None | PWD Volume-2 SR2023-24 Page No 21 Item 7.1.1 | Providing & fixing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete as per design drawings (up to any pitch in horizontal/ vertical
or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required as per the direction of Engineer in charge. ---- complete as per Specification and as directed by the Engineer in-charge of work | Cum | 1089.08 | 1089.08 | 8.64 | False | None | None | False | None | False | 9409.6512 | 0 |
|
|
---|