1707295354000 | 1 | None | None | Other Works | Construction of CC Drain, CC Road and Development of Building and burial ground works in T Narasipura TMC limits Under Amruth nagarothana performance grant | 8453336.02 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2493233 | 75536 | None | code01 | Scarifying the existing bituminous road surface to a depth of 50 mm and disposal of scarified material by Mechanical Means using Hydraulic excavator with in all lifts and lead. Si No.3.5, 305.4.3, Page No.17 of PWD SR 2023-24 of Volume3. | Sqm | 6.18 | 6.18 | 1947.0 | False | None | None | False | None | False | 12032.46 | 0 | 2493234 | 75536 | None | code02 | Dismantling of cement concrete pavement by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 m3 in volume and stock piling at designated locations and disposal of dismantled materials and stacking serviceable and unserviceable materials separately. Si No.2.19, Ref. to MoRT&H Spec. 202, Page No.12 of PWD SR 2023-24 of Volume3. | Cum | 579.89 | 579.89 | 1396.42 | False | None | None | False | None | False | 809769.9938 | 0 | 2493235 | 75536 | None | code03 | Providing and constructing un-reinforced plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including construction joints, , primer, sealant , curing of concrete slabs for 14- days, and water finishing to lines and grade as per drawing and technical specification clause 1501 with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments etc., complete. as per the directions of the Engineer-in-charge of the work. Si No.16.27, Page No.148 of PWD SR 2023-24 of Volume3. | Cum | 6565.22 | 6565.22 | 179.3919 | False | None | None | False | None | False | 1177747.289718 | 0 | 2493236 | 75536 | None | code04 | Dry Lean Cement Concrete Sub- base Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ m3, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing.. Si No.6.1, Ref. to MoRT&H Spec. 602, Page No.49 of PWD SR 2023-24 of Volume3. . | Cum | 5067.6 | 5067.6 | 139.642 | False | None | None | False | None | False | 707649.7992 | 0 | 2493237 | 75536 | None | code05 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. Sl. No.1.14.1, Page No.8 of PWD SR 2023-24 of Volume1. | Cum | 105.06 | 105.06 | 182.72 | False | None | None | False | None | False | 19196.5632 | 0 | 2493238 | 75536 | None | code06 | Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. In all kinds of soils. Depth upto 1.50m (PWD CSR 2023-24 I No 1.6.1, P No 6, Vol 1) | Cum | 498.52 | 498.52 | 72.216 | False | None | None | False | None | False | 36001.12032 | 0 | 2493239 | 75536 | None | code07 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately),MIX 1:4:8 (M10) Using 40 mm and down size graded crushed coarse aggregates. (PWD CSR 2023-24 I No 2.1.3, P No 15, Vol 1) | Cum | 6168.67 | 6168.67 | 10.962 | False | None | None | False | None | False | 67620.96054 | 0 | 2493240 | 75536 | None | code08 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other
incidental charges complete as per the direction of engineer incharge of work. (PWD CSR 2023-24 I No 6.1, P No 13, Vol 2) | Cum | 8466.6 | 8466.6 | 0.396 | False | None | None | False | None | False | 3352.7736 | 0 | 2493241 | 75536 | None | code09 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl. No.8.4.2. Page No.41 of PWD SR 2023-24 of Volume2. | Sqm | 321.36 | 321.36 | 1.44 | False | None | None | False | None | False | 462.7584 | 0 | 2493242 | 75536 | None | code10 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.. (PWD COMMON SR 2023-24 VOL.2 Pg.No.45, It.No.8.27) | Sqm | 54.59 | 54.59 | 1.44 | False | None | None | False | None | False | 78.6096 | 0 | 2493243 | 75536 | None | code11 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand). Sl. No.5.4, Page No.9 of PWD SR 2023-24 of Volume2. | Cum | 6580.67 | 6580.67 | 48.38 | False | None | None | False | None | False | 318372.8146 | 0 | 2493244 | 75536 | None | code12 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately). Mix 1:5:10 Using 40 mm nominal size graded crushed coarse aggregates. Sl. No.2.1.1, Page No.15 of PWD SR 2023-24 of Volume1. | Cum | 5498.14 | 5498.14 | 20.215 | False | None | None | False | None | False | 111144.9001 | 0 | 2493245 | 75536 | None | code13 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Si No.6.2, Page No.13 of PWD SR 2023-24 of Volume2. | Cum | 8217.34 | 8217.34 | 4.68 | False | None | None | False | None | False | 38457.1512 | 0 | 2493246 | 75536 | None | code14 | Providing and laying Cement concrete flooring 40 mm thick with 20mm nominal size stone aggregate using 1:2:4 (1 cement : 2 coarsesand : 4 graded stone aggregate) finished with a floating coat of neatcement, including cement slurry complete. Si No.9.1, Page No.59 of PWD SR 2023-24 of Volume2. | Sqm | 464.53 | 464.53 | 46.8 | False | None | None | False | None | False | 21740.004 | 0 | 2493247 | 75536 | None | code15 | Providing and laying to required line and slope roofing with semi corrugated ( Trafford ) asbestos cement sheet 6mm. thick fixed with galvanised iron J or L hooks, bolts and nuts 8mm. dia C.I plain and bitumen washers, over the existing purlins, rafters and trusses including cost of materials, labour, complete as per specifications.Si No.7.19, Page No.23 of PWD SR 2023-24 of Volume2 | Sqm | 385.22 | 385.22 | 42.0 | False | None | None | False | None | False | 16179.24 | 0 | 2493248 | 75536 | None | code16 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately). M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Sl. No.2.5.2, Page No.16 of PWD SR2023-24 of Volume1. | Cum | 7048.29 | 7048.29 | 8.62 | False | None | None | False | None | False | 60756.2598 | 0 | 2493249 | 75536 | None | code17 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Sl. No.2.3.1, Page No.16 of PWD SR 2023-24 of Volume1. | Cum | 6512.69 | 6512.69 | 5.0624 | False | None | None | False | None | False | 32969.841856 | 0 | 2493250 | 75536 | None | code18 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. Sl. No.1.9, Page No.7 of PWD SR 2023-24 of Volume1. | Cum | 273.98 | 273.98 | 4.84 | False | None | None | False | None | False | 1326.0632 | 0 | 2493251 | 75536 | None | code19 | Appendix I -Additionalities for Formwork, Centering & Scaffolding. Following additional percentage to be added to the finished rates of concrete of Buildings, Irrigation works, Water supply works, Roads & Bridges depending upon the type of structure. These percentages are worked out based on empirical mathematical approaches & exhaustive studies on the common standard sizes of the type of the structure of Buildings, Irrigation works, Bridges, Water works etc. The use rate of shuttering material is considered at 40 repetitions and type of material to be used is steel centering. 2023-24 VOL.1 COMMON SR- PAGE : 111 - 112 -Percentage on finished rate of concrete per m3. For Columns. (70%) | Cum | 4933.8 | 4933.8 | 8.62 | False | None | None | False | None | False | 42529.356 | 0 | 2493252 | 75536 | None | code20 | Appendix I -Additionalities for Formwork, Centering & Scaffolding. Following additional percentage to be added to the finished rates of concrete of Buildings, Irrigation works, Water supply works, Roads & Bridges depending upon the type of structure. These percentages are worked out based on empirical mathematical approaches & exhaustive studies on the common standard sizes of the type of the structure of Buildings, Irrigation works, Bridges, Water works etc. The use rate of shuttering material is considered at 40 repetitions and type of material to be used is steel centering. Revision to 2023-24 VOL.1 COMMON SR- PAGE : 111- 112 | Cum | 3948.4 | 3948.4 | 6.45 | False | None | None | False | None | False | 25467.18 | 0 | 2493253 | 75536 | None | code21 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification( Sl. No.2.11, Page No.18 of PWD SR 2023-24 of Volume 1 | Tonne | 92140.71 | 92140.71 | 1.2858 | False | None | None | False | None | False | 118474.524918 | 0 | 2493254 | 75536 | None | code22 | Appendix I -Additionalities for Formwork, Centering & Scaffolding. Following additional percentage to be added to the finished rates of concrete of Buildings, Irrigation works, Water supply works, Roads & Bridges depending upon the type of structure. These percentages are worked out based on empirical mathematical approaches & exhaustive studies on the common standard sizes of the type of the structure of Buildings, Irrigation works, Bridges, Water works etc. The use rate of shuttering material is considered at 40 repetitions and type of material to be used is steel centering. 2023-24, Vol.1 Common SR -Page :111 percentage on finished rate of Concrete per m3. For Foundation, Sub structure of Cross Drainages. (35%) (concrete Item No 2.4.2 Vol 1) | Cum | 2402.74 | 2402.74 | 5.0625 | False | None | None | False | None | False | 12163.87125 | 0 | 2493255 | 75536 | None | code23 | Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications. Sl No.1.10, Page No.07 of PWD SR 2023-24 of Volume1. | Cum | 164.8 | 164.8 | 4.5 | False | None | None | False | None | False | 741.6 | 0 | 2493256 | 75536 | None | code24 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. (P. No.13, I. No.6.7, Volume-2 2023-24) | Sqm | 8457.33 | 8457.33 | 46.92 | False | None | None | False | None | False | 396817.9236 | 0 | 2493257 | 75536 | None | code25 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. (P. No.14, I. No.6.15, Volume-2,SR-2023-24) | Sqm | 1063.99 | 1063.99 | 48.02 | False | None | None | False | None | False | 51092.7998 | 0 | 2493258 | 75536 | None | code26 | Providing Brick work with common burnt clay machine moulded perforated bricks of class designation 5.0 conforming to IS: 2222 in superstructure above plinth level in cement mortar 1:6 (1 cement : 6 coarse sand) With Non modular bricks including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. (P.NO. 13/ I.No 6.5 PWD SR 2023-24) | Cum | 11306.31 | 11306.31 | 1.16 | False | None | None | False | None | False | 13115.3196 | 0 | 2493259 | 75536 | None | code27 | Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications (P.NO. 23/ I.No 7.18 PWD SR 2023-24 Vol-2) | Cum | 2077.51 | 2077.51 | 29.03 | False | None | None | False | None | False | 60310.1153 | 0 | 2493260 | 75536 | None | code28 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Item No.8.3.1. Page No.41 of PWD SR 2023-24 of Volume 2.) | Sqm | 364.62 | 364.62 | 6.92 | False | None | None | False | None | False | 2523.1704 | 0 | 2493261 | 75536 | None | code29 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl. No.8.1.1. Page No.41 of PWD SR 2023-24 of Volume2. | Sqm | 262.65 | 262.65 | 247.44 | False | None | None | False | None | False | 64990.116 | 0 | 2493262 | 75536 | None | code30 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix 1:3 (1 cement: 3 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl. No.8.5.1, Page No.42 of PWD SR 2023-24 of Volume2. | Sqm | 376.98 | 376.98 | 224.32 | False | None | None | False | None | False | 84564.1536 | 0 | 2493263 | 75536 | None | code31 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl. No.8.9, Page No.42 of PWD SR 2023-24 of Volume2. | Sqm | 396.55 | 396.55 | 478.19 | False | None | None | False | None | False | 189626.2445 | 0 | 2493264 | 75536 | None | code32 | Compacting Original Ground, Compacting original ground supporting embankment, Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction.(vol 3, it no.3.7 pg 17, Ref. to MoRT&H Spec.305.3.4 pwd sr 2023-24) | Sqm | 108.15 | 108.15 | 468.9 | False | None | None | False | None | False | 50711.535 | 0 | 2493265 | 75536 | None | code33 | Wet Mix Macadam (Plant mix method). Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. Si No.4.17, 406, A Page No.26 of PWD SR 2023-24 of Volume3. | Cum | 2635.77 | 2635.77 | 351.68 | False | None | None | False | None | False | 926947.5936 | 0 | 2493266 | 75536 | None | code34 | Prime Coat over WMM/WBM Providing and applying primer coat with SS1 grade Bitumen Emulsion on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.90 kg per m2 using mechanical means. Si No.5.1, 502, A (i) Page No.31 of PWD SR 2023-24 of Volume3. | Sqm | 42.23 | 42.23 | 1947.0 | False | None | None | False | None | False | 82221.81 | 0 | 2493267 | 75536 | None | code35 | Bituminous Macadam Grading - I for traffic less than 20 MSA Providing and laying Bituminous Macadam with 120 TPH capacity hot mix plant batch type using crushed aggregates of specified grading premixed with bituminous binder VG-30 @ 3.3% by weight of mix, transported to site, laid over a previously prepared surface with mechanical paver finisher to the required grade, level and alignment and rolled as per clauses 501.6 and 501.7 to achieve the desired compaction. Si No.5.6.a, 504, (i), A Page No.31 of PWD SR 2023-24 of Volume3. | Cum | 7762.08 | 7762.08 | 97.35 | False | None | None | False | None | False | 755638.488 | 0 | 2493268 | 75536 | None | code36 | Tack coat on Bituminous surface Providing and applying tack coat with RS1 Bituminous Emulsion using emulsion pressure distributor at the rate of 0.20 kg/m2 on the prepared bituminous surface cleaned with mechanical broom. Si No.5.3, 503, (i), Page No.31 of PWD SR 2023-24 of Volume3. | Sqm | 12.36 | 12.36 | 1947.0 | False | None | None | False | None | False | 24064.92 | 0 | 2493269 | 75536 | None | code37 | Semi Dense Bituminous Concrete Providing and laying Semi Dense Bituminous Concrete with 40/60 TPH capacity hot mix plant batch type using crushed aggregates of specified grading premixed with bituminous binder VG-30 @ 5% by weight of mix and filler, transported to site, laid over a previously prepared surface with mechanical paver finisher to the required grade, level and alignment and rolled as per MoRTH V revision. Si No.5.31, IRC-37: 2018, Page No.43 of PWD SR 2023-24 of Volume3. | Cum | 10456.56 | 10456.56 | 48.68 | False | None | None | False | None | False | 509025.3408 | 0 | 2493270 | 75536 | None | code38 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding Sl No.11.34A, Page No.86 of PWD SR 2023-24 of Volume2. | Kg | 173.04 | 173.04 | 304.2 | False | None | None | False | None | False | 52638.768 | 0 | 2493271 | 75536 | None | code39 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size -2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sl. No.12.90, Page No.110 of PWD SR 2023-24 of Volume2. | Sqm | 6936.02 | 6936.02 | 11.7 | False | None | None | False | None | False | 81151.434 | 0 | 2493272 | 75536 | None | code40 | Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications..( Vol -2, I No - 12.12, P No - 99, PWD SR - 2023-24 ) | Cum | 127928.06 | 127928.06 | 0.0824 | False | None | None | False | None | False | 10541.272144 | 0 | 2493273 | 75536 | None | code41 | Providing and fixing in position fully panelled Mathi/Nandi wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures).( Vol -2, I No - 12.15 P No - 100, PWD SR- 2023-24 ) | Sqm | 7667.32 | 7667.32 | 2.73 | False | None | None | False | None | False | 20931.7836 | 0 | 2493274 | 75536 | None | code42 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.-do- with both side prelam.( Vol -2, I No - 12.55.1, P No - 104, PWD SR - 2023-24 ) | Sqm | 2436.98 | 2436.98 | 3.78 | False | None | None | False | None | False | 9211.7844 | 0 | 2493275 | 75536 | None | code43 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (vol 2, I no 11.11.2 , pg no 79 pwd S 2021-22) | Kg | 110.21 | 110.21 | 46.13 | False | None | None | False | None | False | 5083.9873 | 0 | 2493276 | 75536 | None | code44 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl. No.8.40, Page No.48 of PWD SR 2023-24 of Volume2. | Sqm | 118.45 | 118.45 | 11.7 | False | None | None | False | None | False | 1385.865 | 0 | 2493277 | 75536 | None | code45 | Finishing walls with Acrylic Smooth exterior paint of required shade: New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl. No.8.30, Page No.46 of PWD SR 2023-24 of Volume2. | Sqm | 179.22 | 179.22 | 480.74 | False | None | None | False | None | False | 86158.2228 | 0 | 2493278 | 75536 | None | code46 | Finishing walls with textured exterior paint of required shade :Old work (Two coats on existing cement paint surface applied @ 3.28 ltr/10 m² including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in- charge. | Sqm | 222.48 | 222.48 | 18.03 | False | None | None | False | None | False | 4011.3144 | 0 | 2493279 | 75536 | None | code47 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Vol -2, I No - 8.33.1 , P No - 46, PWD SR -2023-24 ) | Sqm | 162.74 | 162.74 | 218.961 | False | None | None | False | None | False | 35633.71314 | 0 | 2493280 | 75536 | None | code48 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete ( Vol -2, I No - 10.14 , P No - 71, PWD SR - 2023-24) | Sqm | 1139.18 | 1139.18 | 25.62 | False | None | None | False | None | False | 29185.7916 | 0 | 2493281 | 75536 | None | code49 | Providing and fixing white vitreous china pedestal type water closet(European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fitting & C.I brackets,40mm flush bend, Overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets,cutting and making good the walls and floors wherever required.(W.C. pan with ISI marked white solid plastic seat and lid)(PWD SR 2023-24 I.No 14.3.1, Page No 131, Vol-2) | Nos | 6156.31 | 6156.31 | 2.0 | False | None | None | False | None | False | 12312.62 | 0 | 2493282 | 75536 | None | code50 | Providing and fixing wash basin with C.I brackets,15mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the wall wherever required: using white vitreous china wash basin size 550x400mm with a 15mm CP Brass single hole basin mixer. (PWD SR 2023-24 14.7.1 P No 132 Vol 2) | Nos | 3174.6 | 3174.6 | 2.0 | False | None | None | False | None | False | 6349.2 | 0 | 2493283 | 75536 | None | code51 | Providing and fixing PVC waste pipefor sink or wash basin including PVC waste fittings complete-32mm dia semi rigid pipe. (PWD SR 2023-24 I.No 14.28.1.1, Page No 136, Vol-2) | Nos | 78.28 | 78.28 | 2.0 | False | None | None | False | None | False | 156.56 | 0 | 2493284 | 75536 | None | code52 | Providing and fixing PVC waste pipefor sink or wash basin including PVC waste fittings complete-40mm dia semi rigid pipe (PWD SR 2023-24 I.No 14.28.1.2, Page No 136, Vol-2) | Nos | 90.64 | 90.64 | 2.0 | False | None | None | False | None | False | 181.28 | 0 | 2493285 | 75536 | None | code53 | Providing and fixing PVC waste pipefor sink or wash basin including PVC waste fittings complete-32mm dia flexible pipe(PWD SR 2023-24 I.No 14.28.2.1, Page No 136, Vol-2) | Nos | 94.76 | 94.76 | 2.0 | False | None | None | False | None | False | 189.52 | 0 | 2493286 | 75536 | None | code54 | Providing and fixing PVC waste pipefor sink or wash basin including PVC waste fittings complete- 40mm dia flexible pipe (PWD SR 2023-24 I.No 14.28.2.2, Page No 136, Vol-2) | Nos | 94.76 | 94.76 | 2.0 | False | None | None | False | None | False | 189.52 | 0 | 2493287 | 75536 | None | code55 | Providing and fixing PTMT Bottle Trap for wash basin and sink.Bottle trap 31mm single piece moulded with height of 270mm, effective length of tail pipe 260 mm from the center of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260gms (PWD SR 2023-24 I.No 14.37.1, Page No 137, Vol-2) | Nos | 315.18 | 315.18 | 2.0 | False | None | None | False | None | False | 630.36 | 0 | 2493288 | 75536 | None | code56 | Providing and fixing brass bib cock of approved quality: 20 mm nominal bore (PWD SR 2023-24 I.No 13.2.2, Page No 117, Vol-2) | Nos | 314.15 | 314.15 | 6.0 | False | None | None | False | None | False | 1884.9 | 0 | 2493289 | 75536 | None | code57 | Providing and fixing brass stop cock of approved quality:(PWD SR 2023-24 I.No 13.3.2, Page No 117, Vol-2) | Nos | 314.15 | 314.15 | 8.0 | False | None | None | False | None | False | 2513.2 | 0 | 2493290 | 75536 | None | code58 | Providing and fixing ball valve (brass) of approved quality, high or low pressure, with plastic float complete:20 mm nominal bore (PWD SR 2023-24 I.No 13.5.2, Page No 117, Vol-2) | Nos | 323.42 | 323.42 | 1.0 | False | None | None | False | None | False | 323.42 | 0 | 2493291 | 75536 | None | code59 | Providing and fixing brass ferrule with C.I mouth cover including boring and tapping the main:25mm nominal bore (PWD SR 2023-24 I.No 13.7.3, Page No 118, Vol-2) | Nos | 442.9 | 442.9 | 10.0 | False | None | None | False | None | False | 4429.0 | 0 | 2493292 | 75536 | None | code60 | Providing and fixing unplasticised PVC connection pipe with brass union:20mm nominal bore (30 cm length) (PWD SR 2023-24 I.No 13.8.1.2, Page No 118, Vol-2) | Nos | 93.73 | 93.73 | 20.0 | False | None | None | False | None | False | 1874.6 | 0 | 2493293 | 75536 | None | code61 | Providing and fixing C.P. brass shower rose with 15 to 20mm inlet: 150 mm diameter (PWD SR 2023-24 I.No 13.9.2, Page No 118, Vol-2) | Nos | 287.37 | 287.37 | 2.0 | False | None | None | False | None | False | 574.74 | 0 | 2493294 | 75536 | None | code62 | Providing and fixing PTMT grating of approved quality and colour:circular type 125mm nominal dia (PWD SR 2023-24 I.No 13.22.1.2, Page No 120, Vol-2) | Nos | 45.32 | 45.32 | 4.0 | False | None | None | False | None | False | 181.28 | 0 | 2493295 | 75536 | None | code63 | Geophysical investigation at site for sinking borewells for supplying drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers’s method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test. (CSR for water supply & Sewage works I No 12.4, P No 140 Vol 5) | Each | 5446.64 | 5446.64 | 1.0 | False | None | None | False | None | False | 5446.64 | 0 | 2493296 | 75536 | None | code64 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (CSR for water supply & Sewage works I No 12.1.1, P No 139 Vol 5)-0.00 to 50.00 Mtr Depth | Mtr | 381.1 | 381.1 | 50.0 | False | None | None | False | None | False | 19055.0 | 0 | 2493297 | 75536 | None | code65 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (CSR for water supply & Sewage works I No 12.1.2, P No 139 Vol 5)-50.00 to 100.00 Mtr Depth | Mtr | 477.92 | 477.92 | 50.0 | False | None | None | False | None | False | 23896.0 | 0 | 2493298 | 75536 | None | code66 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (CSR for water supply & Sewage works I No 12.1.3, P No 139 Vol 5)100 to 150 Mtr Depth | Mtr | 507.79 | 507.79 | 50.0 | False | None | None | False | None | False | 25389.5 | 0 | 2493299 | 75536 | None | code67 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (CSR for water supply & Sewage works I No 12.1.4, P No 139 Vol 5)150 to 200 Mtr Depth | Mtr | 589.16 | 589.16 | 50.0 | False | None | None | False | None | False | 29458.0 | 0 | 2493300 | 75536 | None | code68 | Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. (CSR for water supply & Sewage works I No 12.32, P No 143 Vol 5) | m | 1990.99 | 1990.99 | 18.0 | False | None | None | False | None | False | 35837.82 | 0 | 2493301 | 75536 | None | code69 | Providing and laying at site of work MS casing caps as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge (CSR for water supply & Sewage works I No 12.34, P No 143 Vol 5) | Each | 168.92 | 168.92 | 1.0 | False | None | None | False | None | False | 168.92 | 0 | 2493302 | 75536 | None | code70 | Providing Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments and instructions of engineer incharge of work. For 3 HP etc. complete, 7.50 HP - 90 LPM @ 165 m = 16 STG Outlet Dia - 2.00" (CSR for Water Supply & Sewerage Works 2023 - 24 I No 13.15.7 P No 152 Vol 5) | Each | 42034.3 | 42034.3 | 1.0 | False | None | None | False | None | False | 42034.3 | 0 | 2493303 | 75536 | None | code71 | Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. (CSR for water supply & Sewage works I No 13.32 P No 156 Vol 5) | Job | 6695.0 | 6695.0 | 1.0 | False | None | None | False | None | False | 6695.0 | 0 | 2493304 | 75536 | None | code72 | Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments.1x3x4 m2 (CSR for water supply & Sewage works I No 13.22.3 P No 154 Vol 5) | m | 139.05 | 139.05 | 180.0 | False | None | None | False | None | False | 25029.0 | 0 | 2493305 | 75536 | None | code73 | Supply and delivery of galvanized mild steel tubes of 6mtr standard length heavy duty (C Class) as per IS 1239 (Part-I) 1990 with latest amendments with ISI Mark (one end fitted with Heavy Duty collar and other end fitted with protective cover), 50 mm (CSR for water supply & Sewage works I No 13.27 P No 155 Vol 5) | Each | 3141.5 | 3141.5 | 28.0 | False | None | None | False | None | False | 87962.0 | 0 | 2493306 | 75536 | None | code74 | Lowering, Laying and Jointing GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) for: 50 mm (CSR for water supply & Sewage works I No 11.20.6 P No 155 Vol 5) | m | 149.35 | 149.35 | 168.0 | False | None | None | False | None | False | 25090.8 | 0 | 2493307 | 75536 | None | code75 | Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments, 50 mm (CSR for water supply & Sewage works I No 13.25 P No 154 Vol 5) | Each | 1287.5 | 1287.5 | 1.0 | False | None | None | False | None | False | 1287.5 | 0 | 2493308 | 75536 | None | code76 | Supply and delivery at site wrought middle steel (galvanized) GI elbow confirming to IS 1239-II, 1991 with latest amendments if any for For 50 mm dia GI elbow, (COMMON SR 2021-2022 Vol-5 PN-144, No-7.6, SOR CODE-N100F), 50 mm (CSR for water supply & Sewage works I No 11.7.6 P No 129 Vol 5) | Each | 275.01 | 275.01 | 2.0 | False | None | None | False | None | False | 550.02 | 0 | 2493309 | 75536 | None | code77 | Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For:Heavy Duty GI Pipe etc. complete. Medium Duty GI pipe of 40mm dia (CSR for Water supply & Sewage works 2023-24 2023-24 Item No 11.2.5, P. No 127, Vol-5) | Mtr | 502.64 | 502.64 | 3.0 | False | None | None | False | None | False | 1507.92 | 0 | 2493310 | 75536 | None | code78 | Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws. 12" x 9" x 1.5" (CSR for water supply & Sewage works I No 5.6.1 P No 14 Vol 6) | Each | 89.61 | 89.61 | 1.0 | False | None | None | False | None | False | 89.61 | 0 | 2493311 | 75536 | None | code79 | Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 32/63 A three phase 4 wire whole current class-1 Accuracy Energy Meter. (CSR for water supply & Sewage works I No 5.35 P No 19 Vol 6) | Each | 5876.15 | 5876.15 | 1.0 | False | None | None | False | None | False | 5876.15 | 0 | 2493312 | 75536 | None | code80 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6A One Way Switch (CSR for water supply & Sewage works I No 3.6.1 P No 9 Vol 6) | Each | 105.06 | 105.06 | 2.0 | False | None | None | False | None | False | 210.12 | 0 | 2493313 | 75536 | None | code81 | Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowerin into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead and lifts, including encasing the pipes alround to a depth of not less than 15cms, with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as pr ISS (contractor will make his own arrangements for procuring water for testing) etc. for-Pepes of SN4 75mm dia (PWD SR 2023-24 I.No 10.2.1, Page No 114, Vol-2) | m | 223.51 | 223.51 | 10.0 | False | None | None | False | None | False | 2235.1 | 0 | 2493314 | 75536 | None | code82 | Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowerin into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead and lifts, including encasing the pipes alround to a depth of not less than 15cms, with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as pr ISS (contractor will make his own arrangements for procuring water for testing) etc. for: Pipes of SN4, 110mm dia (PWD SR 2023-24 I.No 10.2.2, Page No 114, Vol-2) | m | 296.64 | 296.64 | 10.0 | False | None | None | False | None | False | 2966.4 | 0 | 2493315 | 75536 | None | code83 | Supply and delivery at site special moulded variety PVC reducer as per IS:7834/1987 and fabricated as per IG124/1984 with ISI mark with its latest amendments 75mm dia PVC reducer (PWD SR 2023-24 I.No 10.13.6, Page No 119, Vol-2) | Nos | 107.12 | 107.12 | 20.0 | False | None | None | False | None | False | 2142.4 | 0 | 2493316 | 75536 | None | code84 | Supply and delivery at site special moulded variety PVC reducer as per IS:7834/1987 and fabricated as per IG124/1984 with ISI mark with its latest amendments-110mm dia PVC Reducer (PWD SR 2023-24 I.No 10.13.8, Page No 119, Vol-2) | Nos | 268.83 | 268.83 | 20.0 | False | None | None | False | None | False | 5376.6 | 0 | 2493317 | 75536 | None | code85 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank (PWD SR 2023-24 I.No 13.34, Page No 123, Vol-2) | Ltr | 9.27 | 9.27 | 3000.0 | False | None | None | False | None | False | 27810.0 | 0 | 2493318 | 75536 | None | code86 | Supply and delivery at site special moulded variety PVC elbows as per IS:7834/1987 and fabricated as per IG124/1984 with ISI mark with its latest amendments 75 mm dia PVC elbow (PWD SR 2023-24 I.No 10.9.6, Page No 117, Vol-2) | Nos | 197.76 | 197.76 | 10.0 | False | None | None | False | None | False | 1977.6 | 0 | 2493319 | 75536 | None | code87 | Supply and delivery at site special moulded variety PVC elbows as per IS:7834/1987 and fabricated as per IG124/1984 with ISI mark with its latest amendments. 110mm dia PVC elbow (PWD SR 2023-24 I.No 10.9.8, Page No 117, Vol-2) | Nos | 311.06 | 311.06 | 10.0 | False | None | None | False | None | False | 3110.6 | 0 | 2493320 | 75536 | None | code88 | Supply and delivery at site special moulded variety PVC bend as per IS:7834/1987 and fabricated as per IG124/1984 with ISI mark with its latest amendments -75mm dia PVC bend (PWD SR 2023-24 I.No 10.11.6, Page No 118, Vol-2) | Each | 252.35 | 252.35 | 9.0 | False | None | None | False | None | False | 2271.15 | 0 | 2493321 | 75536 | None | code89 | Supply and delivery at site special moulded variety PVC bend as per IS:7834/1987 and fabricated as per IG124/1984 with ISI mark with its latest amendments.110mm dia PVC bend (PWD SR 2023-24 I.No 10.11.8, Page No 118, Vol-2) | Each | 506.76 | 506.76 | 9.0 | False | None | None | False | None | False | 4560.84 | 0 | 2493322 | 75536 | None | code90 | Supply and delivery at site special moulded variety PVC couplers as per IS:7834/1987 and fabricated as per IG124/1984 with ISI mark with its latest amendments (PWD SR 2023-24 I.No 10.8.6, Page No 116, Vol-5) | Each | 69.01 | 69.01 | 8.0 | False | None | None | False | None | False | 552.08 | 0 | 2493323 | 75536 | None | code91 | Supply and delivery at site special moulded variety PVC couplers as per IS:7834/1987 and fabricated as per IG124/1984 with ISI mark with its latest amendments 110 mm dia PVC coupler (PWD SR 2023-24 I No 10.8.8 P No 116 Vol 5) | Each | 176.13 | 176.13 | 9.0 | False | None | None | False | None | False | 1585.17 | 0 | 2493324 | 75536 | None | code92 | Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimension ) with modular brick of CD 75 in cement morter 1:6 bed concrete 150mm thick with 1:3:6 plastering 12mm thick with cement morter 1:4CC 1:2:4coping 75mm thick for fixing CI cover & frame etc. excluding the cost of CI frame and cover. (PWD SR 2023-24 I No 16.9 P No 191 Vol 5) | Nos | 5617.62 | 5617.62 | 4.0 | False | None | None | False | None | False | 22470.48 | 0 | 2493325 | 75536 | None | code93 | Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary, 19/20 mm dia 2 mm thick (CSR FOR KPTCL, ESCOMs & PWD Electrical 2023-24 Item No 1.2.1, P. No 2, Vol-6) | Mtr | 67.98 | 67.98 | 150.0 | False | None | None | False | None | False | 10197.0 | 0 | 2493326 | 75536 | None | code94 | Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary, 25 mm dia 2 mm thick (CSR FOR KPTCL, ESCOMs & PWD Electrical 2023-24 Item No 1.2.2, P. No 2, Vol-6) | Mtr | 80.34 | 80.34 | 250.0 | False | None | None | False | None | False | 20085.0 | 0 | 2493327 | 75536 | None | code95 | Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 19/20 mm dia 2 mm thick (CSR FOR KPTCL, ESCOMs & PWD Electrical 2023-24 Item No 1.3.1, P. No 2, Vol-6) | Mtr | 70.04 | 70.04 | 45.0 | False | None | None | False | None | False | 3151.8 | 0 | 2493328 | 75536 | None | code96 | Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.25 mm dia 2 mm thick (CSR FOR KPTCL, ESCOMs & PWD Electrical 2023-24 Item No 1.3.2, P. No 2, Vol-6) | Mtr | 81.37 | 81.37 | 85.0 | False | None | None | False | None | False | 6916.45 | 0 | 2493329 | 75536 | None | code97 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet., Short point upto 3m from tapping point to out let via switch box. (CSR FOR KPTCL, ESCOMs & PWD Electrical 2023-24 Item No 2.1.1, P. No 5, Vol-6) | Point | 293.55 | 293.55 | 18.0 | False | None | None | False | None | False | 5283.9 | 0 | 2493330 | 75536 | None | code98 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood /PVC round block. complete for each outlet. Medium point above 3m upto 6m from tapping point to out let via switch box (CSR FOR KPTCL, ESCOMs & PWD Electrical 2023-24 Item No 2.1.2, P. No 5, Vol-6) | Point | 405.82 | 405.82 | 44.0 | False | None | None | False | None | False | 17856.08 | 0 | 2493331 | 75536 | None | code99 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6m upto 10m from tapping point to out let via switch box (CSR FOR KPTCL, ESCOMs & PWD Electrical 2023-24 Item No 2.1.3, P. No 5, Vol-6) | Point | 587.1 | 587.1 | 65.0 | False | None | None | False | None | False | 38161.5 | 0 | 2493332 | 75536 | None | code100 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. ,Three outlet in a row, above 6m upto 10m from tapping point to out let via switche (CSR FOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024 I.No 2.15, P No 5 Vol 6) | Point | 1066.05 | 1066.05 | 5.0 | False | None | None | False | None | False | 5330.25 | 0 | 2493333 | 75536 | None | code101 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694 confirming to latest amendments. , 1.5 mm2 (CSR FOR KPTCL, ESCOMs & PWD Electrical 2023-24 Item No 2.3.2, P. No 5, Vol-6) | Mtr | 26.78 | 26.78 | 245.0 | False | None | None | False | None | False | 6561.1 | 0 | 2493334 | 75536 | None | code102 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694 confirming to latest amendments. , 2.5 mm2 (CSR FOR KPTCL, ESCOMs & PWD Electrical 2023-24 Item No 2.3.3, P. No 5, Vol-6) | Mtr | 43.26 | 43.26 | 490.0 | False | None | None | False | None | False | 21197.4 | 0 | 2493335 | 75536 | None | code103 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694 confirming to latest amendments. , 4 mm2 (CSR FOR KPTCL, ESCOMs & PWD Electrical 2023-24 Item No 2.3.4, P. No 5, Vol-6) | Mtr | 64.89 | 64.89 | 320.0 | False | None | None | False | None | False | 20764.8 | 0 | 2493336 | 75536 | None | code104 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 10sqmm. (CSR FOR KPTCL, ESCOMs & PWD Electrical 2023-24 Item No 2.3.6, P. No 6, Vol-6) | Mtr | 172.01 | 172.01 | 10.0 | False | None | None | False | None | False | 1720.1 | 0 | 2493337 | 75536 | None | code105 | Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654, 6A 3/5 Way (CSR FOR KPTCL, ESCOMs & PWD Electrical 2023-24 Item No 3.1.2, P. No 8, Vol-6) | Each | 151.41 | 151.41 | 25.0 | False | None | None | False | None | False | 3785.25 | 0 | 2493338 | 75536 | None | code106 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.32A DP Switch (CSR FOR KPTCL, ESCOMs & PWD Electrical 2023-24 Item No 3.6.9, P. No 9, Vol-6) | Each | 335.78 | 335.78 | 4.0 | False | None | None | False | None | False | 1343.12 | 0 | 2493339 | 75536 | None | code107 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6/16A Universal Socket (CSR FOR KPTCL, ESCOMs & PWD Electrical 2023-24 Item No 3.6.10, P. No 9, Vol-6) | Each | 243.08 | 243.08 | 4.0 | False | None | None | False | None | False | 972.32 | 0 | 2493340 | 75536 | None | code108 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, 1-3 Way (CSR FOR KPTCL, ESCOMs & PWD Electrical 2023-24 Item No 3.4.2, P. No 8, Vol-6) | Each | 163.77 | 163.77 | 7.0 | False | None | None | False | None | False | 1146.39 | 0 | 2493341 | 75536 | None | code109 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, 4-5 Way (CSR FOR KPTCL, ESCOMs & PWD Electrical 2023-24 Item No 3.4.3, P. No 8, Vol-6) | Each | 182.31 | 182.31 | 2.0 | False | None | None | False | None | False | 364.62 | 0 | 2493342 | 75536 | None | code110 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall,10-12 way (CSR FOR KPTCL, ESCOMs & PWD Electrical 2023-24 Item No 3.4.6, P. No 8, Vol-6) | Each | 328.57 | 328.57 | 2.0 | False | None | None | False | None | False | 657.14 | 0 | 2493343 | 75536 | None | code111 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall,16-18 way (CSR FOR KPTCL, ESCOMs & PWD Electrical 2023-24 Item No 3.4.8, P. No 8, Vol-6) | Each | 417.15 | 417.15 | 3.0 | False | None | None | False | None | False | 1251.45 | 0 | 2493344 | 75536 | None | code112 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.1 to 3 Module (CSR FOR KPTCL, ESCOMs & PWD Electrical 2023-24 Item No 3.5.2, P. No 8, Vol-6) | Each | 165.83 | 165.83 | 7.0 | False | None | None | False | None | False | 1160.81 | 0 | 2493345 | 75536 | None | code113 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.4 Module (CSR FOR KPTCL, ESCOMs & PWD Electrical 2023-24 Item No 3.5.3, P. No 8, Vol-6) | Each | 180.25 | 180.25 | 2.0 | False | None | None | False | None | False | 360.5 | 0 | 2493346 | 75536 | None | code114 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.8 Module (CSR FOR KPTCL, ESCOMs & PWD Electrical 2023-24 Item No 3.5.5, P. No 8, Vol-6) | Each | 292.52 | 292.52 | 1.0 | False | None | None | False | None | False | 292.52 | 0 | 2493347 | 75536 | None | code115 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.10-12 Module (CSR FOR KPTCL, ESCOMs & PWD Electrical 2023-24 Item No 3.5.6, P. No 8, Vol-6) | Each | 354.32 | 354.32 | 1.0 | False | None | None | False | None | False | 354.32 | 0 | 2493348 | 75536 | None | code116 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.16-18 Module (CSR FOR KPTCL, ESCOMs & PWD Electrical 2023-24 Item No 3.5.8, P. No 8, Vol-6) | Each | 470.71 | 470.71 | 3.0 | False | None | None | False | None | False | 1412.13 | 0 | 2493349 | 75536 | None | code117 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT Greater than 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire Greater than IK08. Power Factor Greater than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED EfficiencyGreater than 1301m/w, nominal CRI Greater than 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned, LED Streetlight 70W (CSR FOR KPTCL, ESCOMs & PWD Electrical 2023-24 Item No 11.8.3, P. No 8, Vol-6) | Each | 6171.76 | 6171.76 | 3.0 | False | None | None | False | None | False | 18515.28 | 0 | 2493350 | 75536 | None | code118 | Supplying and Fixing........mm dia class A GI pipe bracket upto 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/ tubular pole, using suitable clA, bolts, nuts and wiring using suitable capacity wires. Using 25mm dia G.I.Pipe (CSR FOR KPTCL, ESCOMs & PWD Electrical 2023-24 Item No 13.2.1, P. No 56, Vol-6) | Each | 1239.09 | 1239.09 | 3.0 | False | None | None | False | None | False | 3717.27 | 0 | 2493351 | 75536 | None | code119 | Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clA, bolts, nuts and wiring using suitable capacity wires. (CSR FOR KPTCL, ESCOMs & PWD Electrical 2023-24 Item No 13.5, P. No 56, Vol-6) | Each | 166.86 | 166.86 | 4.0 | False | None | None | False | None | False | 667.44 | 0 | 2493352 | 75536 | None | code120 | Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V @50/60Hz & Power factor Greater than 0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition, LED square or round down light 10-12W (CSR FOR KPTCL, ESCOMs & PWD Electrical 2023-24 Item No 11.5.3, P. No 44, Vol-6) | Each | 911.55 | 911.55 | 8.0 | False | None | None | False | None | False | 7292.4 | 0 | 2493353 | 75536 | None | code121 | Supplying of recess mounting non integral type ........ LED w luminaire comprising of pressure decast /extruded aluminium housing, with spring loaded false ceiling clA, Power LEDs with CCT 6500 degree K, CRIGreater than 70%. efficacy Greater than 100 lumen per W, 120degree beam spread, lifeGreater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF Greater than 0.95, power loss shouldless than 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. LED modular down light 1'x1' 24 W (CSR FOR KPTCL, ESCOMs & PWD Electrical 2023-24 Item No 11.6.2, P. No 44, Vol-6) | Each | 3802.76 | 3802.76 | 51.0 | False | None | None | False | None | False | 193940.76 | 0 | 2493354 | 75536 | None | code122 | Supplying of recess mounting non integral type ........ LED w luminaire comprising of pressure decast /extruded aluminium housing, with spring loaded false ceiling clA, Power LEDs with CCT 6500 degree K, CRIGreater than 70%. efficacy Greater than 100 lumen per W, 120degree beam spread, lifeGreater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF Greater than 0.95, power loss shouldless than 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. LED modular down light 2'x2' 36 W (CSR FOR KPTCL, ESCOMs & PWD Electrical 2023-24 Item No 11.6.3, P. No 45, Vol-6) | Each | 4689.59 | 4689.59 | 4.0 | False | None | None | False | None | False | 18758.36 | 0 | 2493355 | 75536 | None | code123 | Supplying & fixing of retrofit type - LED bulb ...... W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRIGreater than 70%. efficacy Greater than 80 lumen per W, lifeGreater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF Greater than 0.95, power loss should less than 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 9W, 6500K (CSR FOR KPTCL, ESCOMs & PWD Electrical 2023-24 Item No 11.11.4, P. No 47, Vol-6) | Each | 158.62 | 158.62 | 25.0 | False | None | None | False | None | False | 3965.5 | 0 | 2493356 | 75536 | None | code124 | Supplying of .....feet -PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor Greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition., LED light fitting 1 x 4' - 20/22 W (CSR FOR KPTCL, ESCOMs & PWD Electrical 2023-24 Item No 11.3.2, P. No 43, Vol-6) | Each | 710.7 | 710.7 | 7.0 | False | None | None | False | None | False | 4974.9 | 0 | 2493357 | 75536 | None | code125 | Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling /rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA. On wall/ ceiling / Rafter / Girders. (CSR FOR KPTCL, ESCOMs & PWD Electrical 2023-24 Item No 13.7.1, P. No56, Vol-6) | Each | 125.66 | 125.66 | 95.0 | False | None | None | False | None | False | 11937.7 | 0 | 2493358 | 75536 | None | code126 | Using necessary length of G.I. chain (CSR FOR KPTCL, ESCOMs & PWD Electrical 2023-24 Item No 13.7.2, P. No56, Vol-6) | Each | 270.89 | 270.89 | 65.0 | False | None | None | False | None | False | 17607.85 | 0 | 2493359 | 75536 | None | code127 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6A Lamp Holder (CSR FOR KPTCL, ESCOMs & PWD Electrical 2023-24 Item No 13.14.6, P. No 10, Vol-6) | Each | 73.13 | 73.13 | 16.0 | False | None | None | False | None | False | 1170.08 | 0 | 2493360 | 75536 | None | code128 | Supplying wall mounting fan suitable to operate at singlephase 230v AC. supply. 300 mm Sweep (CSR FOR KPTCL, ESCOMs & PWD Electrical 2023-24 Item No 6.5.1 , P. No 30, Vol-6) | Each | 2566.76 | 2566.76 | 18.0 | False | None | None | False | None | False | 46201.68 | 0 | 2493361 | 75536 | None | code129 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system.48" Sweep (1200 mm) Regular model (CSR FOR KPTCL, ESCOMs & PWD Electrical 2023-24 Item No 6.3.1, P. No30, Vol-6) | Each | 3073.52 | 3073.52 | 10.0 | False | None | None | False | None | False | 30735.2 | 0 | 2493362 | 75536 | None | code130 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.Stepped Fan Regulator Two Module (CSR FOR KPTCL, ESCOMs & PWD Electrical 2023-24 Item No 3.6.4, P. No 9, Vol-6) | Each | 367.71 | 367.71 | 10.0 | False | None | None | False | None | False | 3677.1 | 0 | 2493363 | 75536 | None | code131 | Fixing a ceiling /wall mounting fan of all capacities and all types, with necessary clA and 'S' hook made out of 15mm dia MS rod, with 5 A. ceiling rose of approved quality with necessary length of 23/0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired.(CSR FOR KPTCL, ESCOMs & PWD Electrical 2023-24 Item No 13.11, P. No 57, Vol-6) | Each | 324.45 | 324.45 | 20.0 | False | None | None | False | None | False | 6489.0 | 0 | 2493364 | 75536 | None | code132 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. 12 Way SP & N (CSR FOR KPTCL, ESCOMs & PWD Electrical 2023-24 Item No 5.19.4, P. No 18, Vol-6) | Each | 1918.89 | 1918.89 | 4.0 | False | None | None | False | None | False | 7675.56 | 0 | 2493365 | 75536 | None | code133 | Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board. 32-40A 2 pole (CSR FOR KPTCL, ESCOMs & PWD Electrical 2023-24 Item No 5.20.4, P. No 18, Vol-6) | Each | 4695.77 | 4695.77 | 4.0 | False | None | None | False | None | False | 18783.08 | 0 | 2493366 | 75536 | None | code134 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. , 5-32 DP (CSR FOR KPTCL, ESCOMs & PWD Electrical 2023-24 Item No 5.18.4, P. No 17, Vol-6) | Each | 761.17 | 761.17 | 40.0 | False | None | None | False | None | False | 30446.8 | 0 | 2493367 | 75536 | None | code135 | Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. , 14SWG(CSR FOR KPTCL, ESCOMs & PWD Electrical 2023-24 Item No 5.42.1, P. No 20, Vol-6) | Sq CM | 0.51 | 0.51 | 99000.0 | False | None | None | False | None | False | 50490.0 | 0 | 2493368 | 75536 | None | code136 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 40x40x6mm. (CSR FOR KPTCL, ESCOMs & PWD Electrical 2023-24 Item No 5.41.1, P. No 20, Vol-6) | Mtr | 314.15 | 314.15 | 3.0 | False | None | None | False | None | False | 942.45 | 0 | 2493369 | 75536 | None | code137 | Supplying .. A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic /FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete, 100 A 4 x 30 x 6 mm Aluminium Strips. (CSR FOR KPTCL, ESCOMs & PWD Electrical 2023-24 Item No 5.40.1, P. No 20, Vol-6) | Mtr | 2538.95 | 2538.95 | 6.0 | False | None | None | False | None | False | 15233.7 | 0 | 2493370 | 75536 | None | code138 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 50x50x6mm. (CSR FOR KPTCL, ESCOMs & PWD Electrical 2023-24 Item No 5.41.2, P. No 20, Vol-6) | Mtr | 406.85 | 406.85 | 6.0 | False | None | None | False | None | False | 2441.1 | 0 | 2493371 | 75536 | None | code139 | Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power,power factor, kVA, kWH, kVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy. (CSR FOR KPTCL, ESCOMs & PWD Electrical 2023-24 Item No 5.33, P. No 19, Vol-6) | Each | 9594.45 | 9594.45 | 1.0 | False | None | None | False | None | False | 9594.45 | 0 | 2493372 | 75536 | None | code140 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C. (CSR FOR KPTCL, ESCOMs & PWD Electrical 2023-24 Item No 5.38, P. No 19, Vol-6) | Each | 530.45 | 530.45 | 3.0 | False | None | None | False | None | False | 1591.35 | 0 | 2493373 | 75536 | None | code141 | Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 32/63 A three phase 4 wire whole current class-1 Accuracy Energy Meter. (CSR FOR KPTCL, ESCOMs & PWD Electrical 2023-24 Item No 5.35, P. No 19, Vol-6) | Each | 5876.15 | 5876.15 | 1.0 | False | None | None | False | None | False | 5876.15 | 0 | 2493374 | 75536 | None | code142 | Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. (Open Execution) 100 A (CSR FOR KPTCL, ESCOMs & PWD Electrical 2023-24 Item No 5.11.2, P. No 15, Vol-6) | Each | 7302.7 | 7302.7 | 1.0 | False | None | None | False | None | False | 7302.7 | 0 | 2493375 | 75536 | None | code143 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 115A (CSR FOR KPTCL, ESCOMs & PWD Electrical 2023-24 Item No 5.14.7, P. No 16, Vol-6) | Each | 20870.89 | 20870.89 | 1.0 | False | None | None | False | None | False | 20870.89 | 0 | 2493376 | 75536 | None | code144 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia (CSR FOR KPTCL, ESCOMs & PWD Electrical 2023-24 Item No 12.56, P. No 54, Vol-6) | Nos | 3615.3 | 3615.3 | 5.0 | False | None | None | False | None | False | 18076.5 | 0 | 2493377 | 75536 | None | code145 | Guy Wire & GI Wire as per IS-2141, GI Wire 8 SWG (CSR FOR KPTCL, ESCOMs & PWD Electrical 2023-24 Item No 8.02, P. No 55, Vol-6) | Mtr | 77291.2 | 77291.2 | 0.045 | False | None | None | False | None | False | 3478.104 | 0 | 2493378 | 75536 | None | code146 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975, 16 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm) (PWD CSR 2023-24 I No 32.05, P No 13, Vol 1) | Km | 146097.26 | 146097.26 | 0.075 | False | None | None | False | None | False | 10957.2945 | 0 | 2493379 | 75536 | None | code147 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975, 25 Sqmm, 3.5 Core, (12 GI Strips - 4 x 0.8 mm) (CSR FOR KPTCL, ESCOMs & PWD Electrical 2023-24 Item No 32.07, P. No 13, Vol-6) | Km | 143735.47 | 143735.47 | 0.1 | False | None | None | False | None | False | 14373.547 | 0 | 2493380 | 75536 | None | code148 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable 2.5 to 25 Sqmm (CSR FOR KPTCL, ESCOMs & PWD Electrical 2023-24 Item No 21.05, P. No 52, Vol-6) | Km | 21512.58 | 21512.58 | 0.175 | False | None | None | False | None | False | 3764.7015 | 0 | 2493381 | 75536 | None | code149 | Optical Fibre Cable (OFC) and its Accessories, HDPE/PLB Pipe 40/33 mm. (CSR FOR KPTCL, ESCOMs & PWD Electrical 2023-24 Item No 66.05, P. No 30, Vol-6) | Km | 87564.42 | 87564.42 | 0.06 | False | None | None | False | None | False | 5253.8652 | 0 | 2493382 | 75536 | None | code150 | Aluminium End Terminal (Lug) (CSR FOR KPTCL, ESCOMs & PWD Electrical 2023-24 Item No 60.2, P. No 27, Vol-6) | Each | 9.27 | 9.27 | 8.0 | False | None | None | False | None | False | 74.16 | 0 | 2493383 | 75536 | None | code151 | Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For:Heavy Duty GI Pipe etc. complete. Medium Duty GI pipe of 50mm dia (CSR FOR KPTCL, ESCOMs & PWD Electrical 2023-24 Item No 11.2.6, P. No 127, Vol-6) | Mtr | 601.52 | 601.52 | 15.0 | False | None | None | False | None | False | 9022.8 | 0 | 2493384 | 75536 | None | code152 | Aluminium End Terminal (Lug), 25 Sqmm (CSR FOR KPTCL, ESCOMs & PWD Electrical 2023-24 Item No 60.3, P. No 27, Vol-6) | Each | 3.09 | 3.09 | 8.0 | False | None | None | False | None | False | 24.72 | 0 | 2493385 | 75536 | None | code153 | Epoxy Terminating Kit (Pothead) suitable for 1.1 kV, LTUG Cable, Up to 4C x 50 Sqmm (CSR FOR KPTCL, ESCOMs & PWD Electrical 2023-24 Item No 35.01, P. No 15, Vol-6) | Set | 333.72 | 333.72 | 2.0 | False | None | None | False | None | False | 667.44 | 0 | 2493386 | 75536 | None | code154 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.8 Way (CSR FOR KPTCL, ESCOMs & PWD Electrical 2023-24 Item No 3.3.51, P. No 8, Vol-6) | Each | 225.57 | 225.57 | 1.0 | False | None | None | False | None | False | 225.57 | 0 | 2493387 | 75536 | None | code155 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers.. 63 amps (CSR FOR KPTCL, ESCOMs & PWD Electrical 2023-24 Item No 5.7.3, P. No 15, Vol-6) | Each | 413.03 | 413.03 | 3.0 | False | None | None | False | None | False | 1239.09 | 0 | 2493388 | 75536 | None | code156 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers.. 32 amps (CSR FOR KPTCL, ESCOMs & PWD Electrical 2023-24 Item No 5.7.2, P. No 15, Vol-6) | Each | 248.23 | 248.23 | 3.0 | False | None | None | False | None | False | 744.69 | 0 | 2493389 | 75536 | None | code157 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63Amps TPN (CSR FOR KPTCL, ESCOMs & PWD Electrical 2023-24 Item No 5.18.9, P. No 18, Vol-6) | Each | 3180.64 | 3180.64 | 6.0 | False | None | None | False | None | False | 19083.84 | 0 | 2493390 | 75536 | None | code158 | Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board. 63 A 4 pole (CSR FOR KPTCL, ESCOMs & PWD Electrical 2023-24 Item No 5.20.10, P. No 18, Vol-6) | Each | 5711.35 | 5711.35 | 1.0 | False | None | None | False | None | False | 5711.35 | 0 | 2493391 | 75536 | None | code159 | Supplying, fixing and wiring heavy duty low voltage capacitor s conforming to IS2834. 3phase, 400/440V grade, for power factor improvement of rotating machineries like induction motor. (CSR FOR KPTCL, ESCOMs & PWD Electrical 2023-24 Item No 5.37, P. No 19, Vol-6) | Kvar | 494.4 | 494.4 | 3.0 | False | None | None | False | None | False | 1483.2 | 0 | 2493392 | 75536 | None | code160 | Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter, 6 to 15 (CSR FOR KPTCL, ESCOMs & PWD Electrical 2023-24 Item No 13.23.3, P. No 155, Vol-6) | Each | 16377.0 | 16377.0 | 1.0 | False | None | None | False | None | False | 16377.0 | 0 | 2493393 | 75536 | None | code161 | Labour charges for erection of outdoor type panel board and meter board units with all necessary materials and labour, tools and equipments including providing cement concrete foundation bed etc., complete as per specification, with testing of as per instructions of engineer incharge of work. (CSR FOR KPTCL, ESCOMs & PWD Electrical 2023-24 Item No 13.34, P. No 156, Vol-6) | Job | 1493.5 | 1493.5 | 1.0 | False | None | None | False | None | False | 1493.5 | 0 | 2493394 | 75536 | None | code162 | Supplying .. A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic /FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete, 100 A 4 x 30 x 6 mm Aluminium Strips. (CSR FOR KPTCL, ESCOMs & PWD Electrical 2023-24 Item No 5.40.1, P. No 20, Vol-6) | Mtr | 2538.95 | 2538.95 | 1.5 | False | None | None | False | None | False | 3808.425 | 0 |
|