createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1707373730319
version3
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeONE_COVER
evaluationTypeTextOne Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee500.00
emd23800.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose23-02-2024 16:28:50
tenderQueryClose22-02-2024 17:00:46
technicalBidOpenNone
publishedDate08-02-2024 17:10:58
publishedByPostDMA_EE3_CC_MYS
publishedByUserKPE11883 - D ASHWIN
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonEXECUTIVE ENGINEER
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08212418849
mobileNumberNone
tenderSupplierListNone
tenderSchedule
createdTs1707373730353
version4
createdDateNone
modifiedDateNone
tenderNumberDMA/2023-24/WS/WORK_INDENT14459
titleConstruction of Reverse Osmosis Water Plant Near Medical Quarters premises colony, ward no-23 of Mysuru City.
descriptionConstruction of Reverse Osmosis Water Plant Near Medical Quarters premises colony, ward no-23 of Mysuru City.
categoryWORKS
categoryTextWorks
ecv856026.82
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2163
locationNameDMA City Corporation Mysuru
provisionalAmount950000.0
groupOverheadTotalNone
fileNumberMCC/WSUGD/WEST-1/JE-1/W-23/RO/2023-24/01
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17073737300000NoneNoneWater supply/sewage linesConstruction of Reverse Osmosis Water Plant Near Medical Quarters premises colony, ward no-23 of Mysuru City.856026.82
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
250492076149Nonecode01Earth work in surface excavation for stripping, seating of bund, Road way by manual means for lowering & levelling the ground for all works other than foundation & depth in Ordinary rock and soft rock upto 300mm depth as per drawing and technical specifications, including setting out, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work.Cum474.6474.63.38FalseNoneNoneFalseNoneFalse1604.1480
250492176149Nonecode02Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m.Cum195.3195.311.07FalseNoneNoneFalseNoneFalse2161.9710
250492276149Nonecode03Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:5:10 Using 40 mm nominal size graded crushed coarse aggregatesCum5224.85224.83.01FalseNoneNoneFalseNoneFalse15726.6480
250492376149Nonecode04Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand)Cum5065.25065.25.28FalseNoneNoneFalseNoneFalse26744.2560
250492476149Nonecode05Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregatesCum6400.86400.81.146FalseNoneNoneFalseNoneFalse7335.31680
250492576149Nonecode06Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications including formwork. (The cost of steel reinforcement, dowel bars to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6473.556473.552.362FalseNoneNoneFalseNoneFalse15290.52510
250492676149Nonecode07Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)Kgs92.492.476.76FalseNoneNoneFalseNoneFalse7092.6240
250492776149Nonecode08Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. B170Cum214.2214.210.06FalseNoneNoneFalseNoneFalse2154.8520
250492876149Nonecode09Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1120.351120.3545.02FalseNoneNoneFalseNoneFalse50438.1570
250492976149Nonecode10Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation com plete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x0.90 mm M.S. laths with 0.90 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-ChargeSqm2311.322311.324.41FalseNoneNoneFalseNoneFalse10192.92120
250493076149Nonecode11KSRB 7.6 : Providing and fixing top covers made out of 20 guage M.S. sheet over pull and push rolling shutters bent to shape including cost of red lead primer coat of painting , materials, labour, HOM of machinery complete as per specifications. Specification No. KBS 7.10.6 / 7.12Rmtr496.46496.462.1FalseNoneNoneFalseNoneFalse1042.5660
250493176149Nonecode12Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDMgasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-ChargeSqm3655.053655.051.8FalseNoneNoneFalseNoneFalse6579.090
250493276149Nonecode13Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingKgs137.55137.5563.0FalseNoneNoneFalseNoneFalse8665.650
250493376149Nonecode14Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-chargeSqm245.7245.747.4FalseNoneNoneFalseNoneFalse11646.180
250493476149Nonecode15Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Page No- 41, Sl No-8.2.1 of SR for BUILDING 2021-22)Sqm265.65265.6553.04FalseNoneNoneFalseNoneFalse14090.0760
250493576149Nonecode16Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 500x500 mmSqm1074.151074.1522.39FalseNoneNoneFalseNoneFalse24050.21850
250493676149Nonecode17Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm117.6117.632.4FalseNoneNoneFalseNoneFalse3810.240
250493776149Nonecode18Providing & fixing of Aluminium Composite paneling (ACP) Sheet name board including Vinyl stickering, sun board sheet including cost of all materials, labour, HOM of machinery, curing complete as per Officer-in-charge. The Rate is inclusive of applicable GSTJob26600.026600.01.0FalseNoneNoneFalseNoneFalse26600.00
250493876149Nonecode19Supply, errection & commissioning of Reverse Osmosis Water Plant of 1000 LPH with Auto dispensing machine & 2000 Liters capacity stnless steel tank with all allied accessories like following, 1)Raw water storage tank 3000 Lts (double coated) ( Sintex or Equivalent : 1No, 2) Supply & installation of 2 HP Raw water feed pump ( Kirloskar / Equivalent): 1No. 3)Dual media filter (DMF) with Sand media 1354 (Pentair/Aventura/Equivalent): 1No. 4) Multiport valve 25NB top mount: 2No, 5)Activated carbon filter (ACF) with carbon media 1354 (Pentair/Aventura/Equivalent): 1No. 6)Antiscalant Dosing System with Dosing tank: 1No. 7)Micron Cartridge Filter (MCF) 10 & 5 Micron: 2No. 8)High pressure pump (HPP) make (CRI/CNP/Equivalent) brand 3 phase: 1No. 9)Reverse Osmosis System (RO) with (UKL/Equivalent) membrane housing: 1No. 10)Membrane (Film tech/Hydranatics/Equivalent ): 1No. 11) Automatic Control Panel (Aster/ Equivalent): 1No. 12)Ph correction dosing with Dosing tank: 1No. 13)Disinfection System Silver Ionization using Novo Technology make (Senco/ Equivalent): 1No. 14)Integrated Contract Plumbing Work (ICPW) CPVC Lines :1 No. 15)Instruments for monitoring PG, Flow meter HPS & LPS: 1No. 16)SS 304 grade Storage tanks 2000 Lts capacity:1No. 17)Coin vending machine with Flow censor & solenoid: 1No. 18)Post Filteration system: 1No. 19) SS transfer pump (CRI/ MAHINDRA/ CNP/ Equivalent): 1No. The Rate is inclusive of applicable GSTJob310000.0310000.01.0FalseNoneNoneFalseNoneFalse310000.00
250493976149Nonecode20Point Wiring using copper wire with switch Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Short point upto 3Mtr. From the tapping point to outlet via SwitchPoint276.0276.01.0FalseNoneNoneFalseNoneFalse276.00
250494076149Nonecode21Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Medum point above 3Mtr. Upto 6Mtr. From the tapping point to outlet via switchPoint386.0386.01.0FalseNoneNoneFalseNoneFalse386.00
250494176149Nonecode22Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi bstrand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr. Upto 10Mtr. From the tapping point to outlet via switchPoint567.0567.03.0FalseNoneNoneFalseNoneFalse1701.00
250494276149Nonecode23Concealed Conduit Supplying heavy gauge PVC conduit pipe ……mm dia ....... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25mm dia 2mm thickMtr70.070.015.0FalseNoneNoneFalseNoneFalse1050.00
250494376149Nonecode24Concealed Conduit SSupplying heavy gauge PVC conduit pipe ……mm dia ....... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 40mm dia 2.5mm thickMtr106.0106.01.5FalseNoneNoneFalseNoneFalse159.00
250494476149Nonecode25Groove Cutting: Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete. upto 50mm conduit in brick wallMtr26.026.012.0FalseNoneNoneFalseNoneFalse312.00
250494576149Nonecode26Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, Finishing with necessary cement plastering complete. 10"x7"x3"Each101.0101.04.0FalseNoneNoneFalseNoneFalse404.00
250494676149Nonecode27Supplying 4mm thick plastic sheet with necessary nitches for fixing switches regulators etc., and fixing on existing wooden or metal box using N.F. screwsSq CM0.290.293250.0FalseNoneNoneFalseNoneFalse942.50
250494776149Nonecode28Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 SqmmMtr26.026.025.0FalseNoneNoneFalseNoneFalse650.00
250494876149Nonecode29Supplying 6A flush type socket and 6 amps flush type SP switch either surface/flush mounting in existing gang box orin 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires asrequired as per IS 1293 and IS 3654 6Amps 3/5 WayEach143.0143.03.0FalseNoneNoneFalseNoneFalse429.00
250494976149Nonecode30Supplying and fixing of modular switch & connectedaccessories on existing modular switch plate as per IS 3854 and IS 1293. (32 Amps DP switchEach375.0375.03.0FalseNoneNoneFalseNoneFalse1125.00
250495076149Nonecode31Supplying and fixing miniature circuit breakers on existingMCB distribution boards using necessary fixing materialsand 'C' Type curve, indicator ON/OFF, energy cross-3 withShort circuit breaking capacity of 10K and complete wiringas required confirming to IEC 60898. 6-32Amps DPEach1103.01103.02.0FalseNoneNoneFalseNoneFalse2206.00
250495176149Nonecode32Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure. III- double door 8 Way TP & NEach4136.04136.01.0FalseNoneNoneFalseNoneFalse4136.00
250495276149Nonecode33Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia.Job3750.03750.01.0FalseNoneNoneFalseNoneFalse3750.00
250495376149Nonecode34Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 4 core 16SqmmMtr113.27113.2720.0FalseNoneNoneFalseNoneFalse2265.40
250495476149Nonecode35Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depthupto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr,Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed. In Ordinary SoilCum260.0260.08.0FalseNoneNoneFalseNoneFalse2080.00
250495576149Nonecode36Providing and laying in position 100mm dia stone ware pipe in existing trenchRmtr39.039.08.0FalseNoneNoneFalseNoneFalse312.00
250495676149Nonecode37Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staf LT UG CableMtr16.1516.1520.0FalseNoneNoneFalseNoneFalse323.00
250495776149Nonecode38Epoxy Terminating Kit (Pothead) suitable for 1.1 kV, LTUG Cable Up to 4C x 50 Sqmm,No316.0316.01.0FalseNoneNoneFalseNoneFalse316.00
250495876149Nonecode39GI Pipe B - Class as per IS-1239, 40mmMtr295.0295.04.0FalseNoneNoneFalseNoneFalse1180.00
250495976149Nonecode40Supplying and fixing of Porcelain fuse channel with cout out on existing wooden/pannel using necessary nuts, bolts and washers ste., complete 63AmpsNo372.0372.06.0FalseNoneNoneFalseNoneFalse2232.00
250496076149Nonecode41Fabricating supplying and mounting MS box made out 18 SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., omplete.Sq CM0.320.326500.0FalseNoneNoneFalseNoneFalse2080.00
250496176149Nonecode42Supplying and fixing of slim box fitting, made out of CRCA Sheet metal body with locking type holder completely wired. Excluding Ballast & Flouresent Tube. 1 x 4' Tube light fitting.Each324.0324.02.0FalseNoneNoneFalseNoneFalse648.00
250496276149Nonecode43Supplying wall mounting fan suitable to operate at single phase 230v AC supply 400mm SweepEach2838.02838.01.0FalseNoneNoneFalseNoneFalse2838.00
250496376149Nonecode44Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps.Each119.0119.02.0FalseNoneNoneFalseNoneFalse238.00
250496476149Nonecode45Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.Each162.0162.01.0FalseNoneNoneFalseNoneFalse162.00
250496576149Nonecode46Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr Lumen Maintenance of 70, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency 130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Street light 40 wattsNo3651.03651.01.0FalseNoneNoneFalseNoneFalse3651.00
250496676149Nonecode47Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 32/63 Amps three phase 4 wire whole current class-1 Accuracy Energy Meter.Each5125.05125.01.0FalseNoneNoneFalseNoneFalse5125.00
250496776149Nonecode48CESC Deposit & Miscellaneous & rounding offJob7500.07500.01.0FalseNoneNoneFalseNoneFalse7500.00
250496876149Nonecode49Geophysical investigation at site for sinking borewells for supplying drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers’s method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test.Each5141.05141.01.0FalseNoneNoneFalseNoneFalse5141.00
250496976149Nonecode50Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata includingover burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation ofrig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) Borewell depth of 0 to 50 mMtr290.0290.050.0FalseNoneNoneFalseNoneFalse14500.00
250497076149Nonecode51Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata includingover burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation ofrig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) Borewell depth of 50 to 100 mMtr364.0364.050.0FalseNoneNoneFalseNoneFalse18200.00
250497176149Nonecode52Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata includingover burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation ofrig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) Borewell depth of 100 to 150 mMtr387.0387.032.0FalseNoneNoneFalseNoneFalse12384.00
250497276149Nonecode53Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium dutyMtr1933.01933.024.0FalseNoneNoneFalseNoneFalse46392.00
250497376149Nonecode54Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with allamendmentsNo150.0150.05.0FalseNoneNoneFalseNoneFalse750.00
250497476149Nonecode55Providing and laying at site of work MS casing caps as per IS 1239 (part- II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in chargeNo164.0164.01.0FalseNoneNoneFalseNoneFalse164.00
250497576149Nonecode56Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. 5.00 HP - 90 LPM @ 110 m = 10 STG Outlet Dia - 2.00Mtr35950.035950.01.0FalseNoneNoneFalseNoneFalse35950.00
250497676149Nonecode57Providing, Laying and Fixing GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For Heavy Duty GI pipe: Heavy Duty GI pipe of 50mm diaMtr546.0546.072.0FalseNoneNoneFalseNoneFalse39312.00
250497776149Nonecode58Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments. 1x3x2.5 m2No98.098.080.0FalseNoneNoneFalseNoneFalse7840.00
250497876149Nonecode59Cutting and threading G.I. pipes for pump fitting, public fountains with appurtenances., where the length of pipe laid is less than 6 metres Pipes of dia 32mm to 80mmNo268.0268.06.0FalseNoneNoneFalseNoneFalse1608.00
250497976149Nonecode60Supplying and erecting of 50 mm dia MS clamp with bolts and nutsNo800.0800.02.0FalseNoneNoneFalseNoneFalse1600.00
250498076149Nonecode61Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments Size 50 mmNo1275.01275.01.0FalseNoneNoneFalseNoneFalse1275.00
250498176149Nonecode62Supply and delivery at site wrought middle steel (galvanized) GI union confirming to IS 1239-II, 1991 with latest amendments if any. For 50 mm dia GI UnionNo219.0219.01.0FalseNoneNoneFalseNoneFalse219.00
250498276149Nonecode63Supply and delivery at site wrought middle steel (galvanized) GI plugs confirming to IS 1239-II, 1991 with latest amendments if any. For 50 mm dia GI PlugsNo163.0163.01.0FalseNoneNoneFalseNoneFalse163.00
250498376149Nonecode64Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of workJob615.0615.01.0FalseNoneNoneFalseNoneFalse615.00
250498476149Nonecode65Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depthCum240.45240.450.34FalseNoneNoneFalseNoneFalse81.7530
250498576149Nonecode66Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregatesCum6844.536844.530.067FalseNoneNoneFalseNoneFalse458.583510
250498676149Nonecode67Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum7387.87387.80.51FalseNoneNoneFalseNoneFalse3767.7780
250498776149Nonecode68Providing Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement :3 coarse sand), finished with a floating coat of neat cement.18mm thickSqm443.1443.13.63FalseNoneNoneFalseNoneFalse1608.4530
250498876149Nonecode69Fabricating Supplying and mounting MS box made out SWG suitable for floor/wall mounting, fully weather proof with provision for better heat dispension, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7 tanks treatment with powder coated paint and finally finished with approved colour etc., complete.Sq CM0.380.3825000.0FalseNoneNoneFalseNoneFalse9500.00
250498976149Nonecode70Supplying and fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers etc., complete 63 AmpsNo372.0372.03.0FalseNoneNoneFalseNoneFalse1116.00
250499076149Nonecode71Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing aterials and C type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10 K and complete wiring as requried. 50 : 63 Amps TPNNo2399.02399.01.0FalseNoneNoneFalseNoneFalse2399.00
250499176149Nonecode72Supplying, fixing and wiring Earth Leakage Miniature circuit breaker (ELMCB) 240/450V upto 300mA sensitivity on existing wood/panel board. 50 : 32 : 40 Amps 4 poleNo3058.03058.01.0FalseNoneNoneFalseNoneFalse3058.00
250499276149Nonecode73Supplying, fixing and wiring heavy duty low voltage capacitors confirming to IS 2834, 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery.Cost per KVARKvar432.0432.02.0FalseNoneNoneFalseNoneFalse864.00
250499376149Nonecode74Supplying fully automatic star-delta starter unit push button type with suitable wires 3 contactors, one adjustable thermal timer mounted on a common base plate held in steel enclosure for use on 400/440 volts 3 phase and wired after fixing to the wooden board for motor. upto 12.5 HPEach6912.06912.01.0FalseNoneNoneFalseNoneFalse6912.00
250499476149Nonecode75Supplying and fixing single phase preventer using necessary wires over an existing panel board suitable for motor upto 20 HP capacities.Each805.0805.01.0FalseNoneNoneFalseNoneFalse805.00
250499576149Nonecode76Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc., using 40mm dia 2.9mm thick 2.5 mtr. Long GI Pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm alround with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nutsNo3750.03750.02.0FalseNoneNoneFalseNoneFalse7500.00
250499676149Nonecode77Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depthupto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr,Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed. In Ordinary SoilMtr102.0102.026.0FalseNoneNoneFalseNoneFalse2652.00
250499776149Nonecode78Providing and laying in position 100mm dia stone ware pipe in existing trench.Mtr39.039.026.0FalseNoneNoneFalseNoneFalse1014.00
250499876149Nonecode79Supplying of 1.1 KV LT UG Cable XLPE or heat resistant PVC Insulated, PVC extruded, inner sheath armoured, UG LT cable as per IS - 1554 (part-1) or IS - 7098 part-1, Armouring strip thickness in average + 5% and resistivity 14 Ohms/kms (max) as per IS-3975.Mtr113.27113.2730.0FalseNoneNoneFalseNoneFalse3398.10
250499976149Nonecode80Labour charges for Laying of 1.1 KV class UG cable in existing trench GI pipe/ store ware pipe, on wall/ on pole as required.6 sqmm to 16 sqmm.Mtr11.8811.8830.0FalseNoneNoneFalseNoneFalse356.40
250500076149Nonecode81Providing and filling sand in excavated trench to cover already laid UG to a depth of 150 mm all-round the cable.Mtr100.0100.018.0FalseNoneNoneFalseNoneFalse1800.00
250500176149Nonecode82GI Pipe - 40 mm DiaMtr295.0295.015.0FalseNoneNoneFalseNoneFalse4425.00
250500276149Nonecode83Epoxy Terminating Kit (Pothead) suitable for 1.1 kV, LTUG Cable Up to 4C x 50 SqmmNo316.0316.01.0FalseNoneNoneFalseNoneFalse316.00
250500376149Nonecode84Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 32/63 Amps three phase 4 wire whole current class-1 Accuracy Energy MeterEach5125.05125.01.0FalseNoneNoneFalseNoneFalse5125.00
250500476149Nonecode85Arranging the power supply from CESCOM and payment of 2 MMD charges towards CESCOM for power sanction.Each7513.397513.391.0FalseNoneNoneFalseNoneFalse7513.390
250500576149Nonecode86Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the workCum493.5493.59.32FalseNoneNoneFalseNoneFalse4599.420
250500676149Nonecode87Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. Note: Upto 110mm dia Coil shall be used. For Grade :HDPE Grade PE80-PN8.0, 90mm diaMtr249.9249.923.0FalseNoneNoneFalseNoneFalse5747.70
250500776149Nonecode88Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specificationsCum128.1128.19.32FalseNoneNoneFalseNoneFalse1193.8920
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17073737340000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17073737340000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17073737340000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17073737340000NoneNoneELIGIBILITYDepartment Registration DetailsNone
17073737340000NoneNoneELIGIBILITYTotal value of civl engineering works executed and payments received in the last five years (year-wise)None
17073737340000NoneNoneELIGIBILITYList of existing commitments and ongoing workNone
17073737340000NoneNoneELIGIBILITYList of works for which tenders already submittedNone
17073737340000NoneNoneELIGIBILITYBanker DetailsNone
17073737380000NoneNoneELIGIBILITYONE.)Any changes/modifications will be notified/updated through eprocurement only. 2.)The Authority reserves the right to accept/reject any or all tenders without assigning any reasons. 3.)Any discrepancies in the tender document shall be brought to the notice of Tender Inviting Authority before the last date 4.)If any, the decision of the Tender Inviting Authority shall be final.5)All documents are to be uploaded through e-portal only. 6)All other conditions as per KW 1 Standard Tender document. 7)The decision of the Tender Inviting Authority shall be final in case of any discrepancies. 8)GST will be paid separately where ever it is applicable. 9.)Work to be carried out as per the direction of Engineer in charge. 10)Bidders are instructed to visit the site before participating in tender. Any objections regarding the items in the Schedule-B shall be brought to the notice of the authority. No objections will be entertained later & work has to be executed in complete manner. 11)Bidders should mention Address for Correspondence, Contact number AND E-mail id in e-portal without fail. 12)Bidders shall submit Original documents as uploaded in e-procurement to the office of Executive Engineer VVWS UGD WEST for verification within 5 days of opening tender. No correspondence shall be made regarding the same from this officeNone
preQualCriterionListNone
technicalCriterionListNone
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
Contractor Registration CertificateTrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone