2504920 | 76149 | None | code01 | Earth work in surface excavation for stripping, seating of bund, Road way by manual means for lowering & levelling the ground for all works other than foundation & depth in Ordinary rock and soft rock upto 300mm depth as per drawing and technical specifications, including setting out, barricading, caution lights, including dressing of excavated
surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. | Cum | 474.6 | 474.6 | 3.38 | False | None | None | False | None | False | 1604.148 | 0 |
2504921 | 76149 | None | code02 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter,
excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m. | Cum | 195.3 | 195.3 | 11.07 | False | None | None | False | None | False | 2161.971 | 0 |
2504922 | 76149 | None | code03 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:5:10 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5224.8 | 5224.8 | 3.01 | False | None | None | False | None | False | 15726.648 | 0 |
2504923 | 76149 | None | code04 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 5065.2 | 5065.2 | 5.28 | False | None | None | False | None | False | 26744.256 | 0 |
2504924 | 76149 | None | code05 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super
plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) Mix 1:2:4 Using 20 mm nominal size graded crushed coarse
aggregates | Cum | 6400.8 | 6400.8 | 1.146 | False | None | None | False | None | False | 7335.3168 | 0 |
2504925 | 76149 | None | code06 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in
layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications including formwork. (The cost of steel reinforcement, dowel bars to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6473.55 | 6473.55 | 2.362 | False | None | None | False | None | False | 15290.5251 | 0 |
2504926 | 76149 | None | code07 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) | Kgs | 92.4 | 92.4 | 76.76 | False | None | None | False | None | False | 7092.624 | 0 |
2504927 | 76149 | None | code08 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. B170 | Cum | 214.2 | 214.2 | 10.06 | False | None | None | False | None | False | 2154.852 | 0 |
2504928 | 76149 | None | code09 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage
charges of machinery etc complete as per specifications. | Sqm | 1120.35 | 1120.35 | 45.02 | False | None | None | False | None | False | 50438.157 | 0 |
2504929 | 76149 | None | code10 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation com plete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x0.90 mm M.S. laths with 0.90 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Sqm | 2311.32 | 2311.32 | 4.41 | False | None | None | False | None | False | 10192.9212 | 0 |
2504930 | 76149 | None | code11 | KSRB 7.6 : Providing and fixing top covers made out of 20 guage M.S. sheet over pull and push rolling shutters bent to shape including cost of red lead primer coat of painting , materials, labour, HOM of machinery complete as per specifications. Specification No. KBS 7.10.6 / 7.12 | Rmtr | 496.46 | 496.46 | 2.1 | False | None | None | False | None | False | 1042.566 | 0 |
2504931 | 76149 | None | code12 | Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDMgasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and
direction of Engineer-in-charge complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Sqm | 3655.05 | 3655.05 | 1.8 | False | None | None | False | None | False | 6579.09 | 0 |
2504932 | 76149 | None | code13 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding | Kgs | 137.55 | 137.55 | 63.0 | False | None | None | False | None | False | 8665.65 | 0 |
2504933 | 76149 | None | code14 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge | Sqm | 245.7 | 245.7 | 47.4 | False | None | None | False | None | False | 11646.18 | 0 |
2504934 | 76149 | None | code15 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Page No- 41, Sl No-8.2.1 of SR for BUILDING 2021-22) | Sqm | 265.65 | 265.65 | 53.04 | False | None | None | False | None | False | 14090.076 | 0 |
2504935 | 76149 | None | code16 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting
the joints with white cement and matching pigments etc., complete. Size of Tile 500x500 mm | Sqm | 1074.15 | 1074.15 | 22.39 | False | None | None | False | None | False | 24050.2185 | 0 |
2504936 | 76149 | None | code17 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 117.6 | 117.6 | 32.4 | False | None | None | False | None | False | 3810.24 | 0 |
2504937 | 76149 | None | code18 | Providing & fixing of Aluminium Composite paneling (ACP) Sheet name board including Vinyl stickering, sun board sheet including cost of all materials, labour, HOM of machinery, curing complete as per Officer-in-charge. The Rate is inclusive of applicable GST | Job | 26600.0 | 26600.0 | 1.0 | False | None | None | False | None | False | 26600.0 | 0 |
2504938 | 76149 | None | code19 | Supply, errection & commissioning of Reverse Osmosis Water Plant of 1000 LPH with Auto dispensing machine & 2000 Liters capacity stnless steel tank with all allied accessories like following, 1)Raw water storage tank 3000 Lts (double coated) ( Sintex or Equivalent : 1No, 2) Supply & installation of 2 HP Raw water feed pump ( Kirloskar / Equivalent): 1No. 3)Dual media filter (DMF) with Sand media 1354 (Pentair/Aventura/Equivalent): 1No. 4) Multiport valve 25NB top mount: 2No, 5)Activated carbon filter (ACF) with carbon media 1354 (Pentair/Aventura/Equivalent): 1No. 6)Antiscalant Dosing System with Dosing tank: 1No. 7)Micron Cartridge Filter (MCF) 10 & 5 Micron: 2No. 8)High pressure pump (HPP) make (CRI/CNP/Equivalent) brand 3 phase: 1No. 9)Reverse Osmosis System (RO) with (UKL/Equivalent) membrane housing: 1No. 10)Membrane (Film tech/Hydranatics/Equivalent ): 1No. 11) Automatic Control Panel (Aster/ Equivalent): 1No. 12)Ph correction dosing with Dosing tank: 1No. 13)Disinfection System Silver Ionization using Novo Technology make (Senco/ Equivalent): 1No. 14)Integrated Contract Plumbing Work (ICPW) CPVC Lines :1 No. 15)Instruments for monitoring PG, Flow meter HPS & LPS: 1No. 16)SS 304 grade Storage tanks 2000 Lts capacity:1No. 17)Coin vending machine with Flow censor & solenoid: 1No. 18)Post Filteration system: 1No. 19) SS transfer pump (CRI/ MAHINDRA/ CNP/ Equivalent): 1No. The Rate is inclusive of applicable GST | Job | 310000.0 | 310000.0 | 1.0 | False | None | None | False | None | False | 310000.0 | 0 |
2504939 | 76149 | None | code20 | Point Wiring using copper wire with switch Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Short point upto 3Mtr. From the tapping point to outlet via Switch | Point | 276.0 | 276.0 | 1.0 | False | None | None | False | None | False | 276.0 | 0 |
2504940 | 76149 | None | code21 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Medum point above 3Mtr. Upto 6Mtr. From the tapping point to outlet via switch | Point | 386.0 | 386.0 | 1.0 | False | None | None | False | None | False | 386.0 | 0 |
2504941 | 76149 | None | code22 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi bstrand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr. Upto 10Mtr. From the tapping point to outlet via switch | Point | 567.0 | 567.0 | 3.0 | False | None | None | False | None | False | 1701.0 | 0 |
2504942 | 76149 | None | code23 | Concealed Conduit Supplying heavy gauge PVC conduit pipe ……mm dia ....... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25mm dia 2mm thick | Mtr | 70.0 | 70.0 | 15.0 | False | None | None | False | None | False | 1050.0 | 0 |
2504943 | 76149 | None | code24 | Concealed Conduit SSupplying heavy gauge PVC conduit pipe ……mm dia ....... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 40mm dia 2.5mm thick | Mtr | 106.0 | 106.0 | 1.5 | False | None | None | False | None | False | 159.0 | 0 |
2504944 | 76149 | None | code25 | Groove Cutting: Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete. upto 50mm conduit in brick wall | Mtr | 26.0 | 26.0 | 12.0 | False | None | None | False | None | False | 312.0 | 0 |
2504945 | 76149 | None | code26 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, Finishing with necessary cement plastering complete. 10"x7"x3" | Each | 101.0 | 101.0 | 4.0 | False | None | None | False | None | False | 404.0 | 0 |
2504946 | 76149 | None | code27 | Supplying 4mm thick plastic sheet with necessary nitches for fixing switches regulators etc., and fixing on existing wooden or metal box using N.F. screws | Sq CM | 0.29 | 0.29 | 3250.0 | False | None | None | False | None | False | 942.5 | 0 |
2504947 | 76149 | None | code28 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 Sqmm | Mtr | 26.0 | 26.0 | 25.0 | False | None | None | False | None | False | 650.0 | 0 |
2504948 | 76149 | None | code29 | Supplying 6A flush type socket and 6 amps flush type SP switch either surface/flush mounting in existing gang box orin 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires asrequired as per IS 1293 and IS 3654 6Amps 3/5 Way | Each | 143.0 | 143.0 | 3.0 | False | None | None | False | None | False | 429.0 | 0 |
2504949 | 76149 | None | code30 | Supplying and fixing of modular switch & connectedaccessories on existing modular switch plate as per IS 3854 and IS 1293. (32 Amps DP switch | Each | 375.0 | 375.0 | 3.0 | False | None | None | False | None | False | 1125.0 | 0 |
2504950 | 76149 | None | code31 | Supplying and fixing miniature circuit breakers on existingMCB distribution boards using necessary fixing materialsand 'C' Type curve, indicator ON/OFF, energy cross-3 withShort circuit breaking capacity of 10K and complete wiringas required confirming to IEC 60898. 6-32Amps DP | Each | 1103.0 | 1103.0 | 2.0 | False | None | None | False | None | False | 2206.0 | 0 |
2504951 | 76149 | None | code32 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure. III- double door 8 Way TP & N | Each | 4136.0 | 4136.0 | 1.0 | False | None | None | False | None | False | 4136.0 | 0 |
2504952 | 76149 | None | code33 | Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia. | Job | 3750.0 | 3750.0 | 1.0 | False | None | None | False | None | False | 3750.0 | 0 |
2504953 | 76149 | None | code34 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 4 core 16Sqmm | Mtr | 113.27 | 113.27 | 20.0 | False | None | None | False | None | False | 2265.4 | 0 |
2504954 | 76149 | None | code35 | Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depthupto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr,Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed. In Ordinary Soil | Cum | 260.0 | 260.0 | 8.0 | False | None | None | False | None | False | 2080.0 | 0 |
2504955 | 76149 | None | code36 | Providing and laying in position 100mm dia stone ware pipe in existing trench | Rmtr | 39.0 | 39.0 | 8.0 | False | None | None | False | None | False | 312.0 | 0 |
2504956 | 76149 | None | code37 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staf LT UG Cable | Mtr | 16.15 | 16.15 | 20.0 | False | None | None | False | None | False | 323.0 | 0 |
2504957 | 76149 | None | code38 | Epoxy Terminating Kit (Pothead) suitable for 1.1 kV, LTUG Cable Up to 4C x 50 Sqmm, | No | 316.0 | 316.0 | 1.0 | False | None | None | False | None | False | 316.0 | 0 |
2504958 | 76149 | None | code39 | GI Pipe B - Class as per IS-1239, 40mm | Mtr | 295.0 | 295.0 | 4.0 | False | None | None | False | None | False | 1180.0 | 0 |
2504959 | 76149 | None | code40 | Supplying and fixing of Porcelain fuse channel with cout out on existing wooden/pannel using necessary nuts, bolts and washers ste., complete 63Amps | No | 372.0 | 372.0 | 6.0 | False | None | None | False | None | False | 2232.0 | 0 |
2504960 | 76149 | None | code41 | Fabricating supplying and mounting MS box made out 18 SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., omplete. | Sq CM | 0.32 | 0.32 | 6500.0 | False | None | None | False | None | False | 2080.0 | 0 |
2504961 | 76149 | None | code42 | Supplying and fixing of slim box fitting, made out of CRCA Sheet metal body with locking type holder completely wired. Excluding Ballast & Flouresent Tube. 1 x 4' Tube light fitting. | Each | 324.0 | 324.0 | 2.0 | False | None | None | False | None | False | 648.0 | 0 |
2504962 | 76149 | None | code43 | Supplying wall mounting fan suitable to operate at single phase 230v AC supply 400mm Sweep | Each | 2838.0 | 2838.0 | 1.0 | False | None | None | False | None | False | 2838.0 | 0 |
2504963 | 76149 | None | code44 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. | Each | 119.0 | 119.0 | 2.0 | False | None | None | False | None | False | 238.0 | 0 |
2504964 | 76149 | None | code45 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. | Each | 162.0 | 162.0 | 1.0 | False | None | None | False | None | False | 162.0 | 0 |
2504965 | 76149 | None | code46 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr Lumen Maintenance of 70, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency 130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Street light 40 watts | No | 3651.0 | 3651.0 | 1.0 | False | None | None | False | None | False | 3651.0 | 0 |
2504966 | 76149 | None | code47 | Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 32/63 Amps three phase 4 wire whole current class-1 Accuracy Energy Meter. | Each | 5125.0 | 5125.0 | 1.0 | False | None | None | False | None | False | 5125.0 | 0 |
2504967 | 76149 | None | code48 | CESC Deposit & Miscellaneous & rounding off | Job | 7500.0 | 7500.0 | 1.0 | False | None | None | False | None | False | 7500.0 | 0 |
2504968 | 76149 | None | code49 | Geophysical investigation at site for sinking borewells for supplying drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers’s method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the
vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test. | Each | 5141.0 | 5141.0 | 1.0 | False | None | None | False | None | False | 5141.0 | 0 |
2504969 | 76149 | None | code50 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata includingover burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation ofrig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) Borewell depth of 0 to 50 m | Mtr | 290.0 | 290.0 | 50.0 | False | None | None | False | None | False | 14500.0 | 0 |
2504970 | 76149 | None | code51 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata includingover burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation ofrig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) Borewell depth of 50 to 100 m | Mtr | 364.0 | 364.0 | 50.0 | False | None | None | False | None | False | 18200.0 | 0 |
2504971 | 76149 | None | code52 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata includingover burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation ofrig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) Borewell depth of 100 to 150 m | Mtr | 387.0 | 387.0 | 32.0 | False | None | None | False | None | False | 12384.0 | 0 |
2504972 | 76149 | None | code53 | Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty | Mtr | 1933.0 | 1933.0 | 24.0 | False | None | None | False | None | False | 46392.0 | 0 |
2504973 | 76149 | None | code54 | Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with allamendments | No | 150.0 | 150.0 | 5.0 | False | None | None | False | None | False | 750.0 | 0 |
2504974 | 76149 | None | code55 | Providing and laying at site of work MS casing caps as per IS 1239 (part- II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge | No | 164.0 | 164.0 | 1.0 | False | None | None | False | None | False | 164.0 | 0 |
2504975 | 76149 | None | code56 | Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. 5.00 HP - 90 LPM @ 110 m = 10 STG Outlet Dia - 2.00 | Mtr | 35950.0 | 35950.0 | 1.0 | False | None | None | False | None | False | 35950.0 | 0 |
2504976 | 76149 | None | code57 | Providing, Laying and Fixing GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For Heavy Duty GI pipe: Heavy Duty GI pipe of 50mm dia | Mtr | 546.0 | 546.0 | 72.0 | False | None | None | False | None | False | 39312.0 | 0 |
2504977 | 76149 | None | code58 | Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments. 1x3x2.5 m2 | No | 98.0 | 98.0 | 80.0 | False | None | None | False | None | False | 7840.0 | 0 |
2504978 | 76149 | None | code59 | Cutting and threading G.I. pipes for pump fitting, public fountains with appurtenances., where the length of pipe laid is less than 6 metres Pipes of dia 32mm to 80mm | No | 268.0 | 268.0 | 6.0 | False | None | None | False | None | False | 1608.0 | 0 |
2504979 | 76149 | None | code60 | Supplying and erecting of 50 mm dia MS clamp with bolts and nuts | No | 800.0 | 800.0 | 2.0 | False | None | None | False | None | False | 1600.0 | 0 |
2504980 | 76149 | None | code61 | Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments Size 50 mm | No | 1275.0 | 1275.0 | 1.0 | False | None | None | False | None | False | 1275.0 | 0 |
2504981 | 76149 | None | code62 | Supply and delivery at site wrought middle steel (galvanized) GI union confirming to IS 1239-II, 1991 with latest amendments if any. For 50 mm dia GI Union | No | 219.0 | 219.0 | 1.0 | False | None | None | False | None | False | 219.0 | 0 |
2504982 | 76149 | None | code63 | Supply and delivery at site wrought middle steel (galvanized) GI plugs confirming to IS 1239-II, 1991 with latest amendments if any. For 50 mm dia GI Plugs | No | 163.0 | 163.0 | 1.0 | False | None | None | False | None | False | 163.0 | 0 |
2504983 | 76149 | None | code64 | Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work | Job | 615.0 | 615.0 | 1.0 | False | None | None | False | None | False | 615.0 | 0 |
2504984 | 76149 | None | code65 | Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depth | Cum | 240.45 | 240.45 | 0.34 | False | None | None | False | None | False | 81.753 | 0 |
2504985 | 76149 | None | code66 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6844.53 | 6844.53 | 0.067 | False | None | None | False | None | False | 458.58351 | 0 |
2504986 | 76149 | None | code67 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of
engineer incharge of work. | Cum | 7387.8 | 7387.8 | 0.51 | False | None | None | False | None | False | 3767.778 | 0 |
2504987 | 76149 | None | code68 | Providing Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement :3 coarse sand), finished with a floating coat of neat cement.18mm thick | Sqm | 443.1 | 443.1 | 3.63 | False | None | None | False | None | False | 1608.453 | 0 |
2504988 | 76149 | None | code69 | Fabricating Supplying and mounting MS box made out SWG suitable for floor/wall mounting, fully weather proof with provision for better heat dispension, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7 tanks treatment with powder coated paint and finally finished with approved colour etc., complete. | Sq CM | 0.38 | 0.38 | 25000.0 | False | None | None | False | None | False | 9500.0 | 0 |
2504989 | 76149 | None | code70 | Supplying and fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers etc., complete 63 Amps | No | 372.0 | 372.0 | 3.0 | False | None | None | False | None | False | 1116.0 | 0 |
2504990 | 76149 | None | code71 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing aterials and C type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10 K and complete wiring as requried. 50 : 63 Amps TPN | No | 2399.0 | 2399.0 | 1.0 | False | None | None | False | None | False | 2399.0 | 0 |
2504991 | 76149 | None | code72 | Supplying, fixing and wiring Earth Leakage Miniature circuit breaker (ELMCB) 240/450V upto 300mA sensitivity on existing wood/panel board. 50 : 32 : 40 Amps 4 pole | No | 3058.0 | 3058.0 | 1.0 | False | None | None | False | None | False | 3058.0 | 0 |
2504992 | 76149 | None | code73 | Supplying, fixing and wiring heavy duty low voltage capacitors confirming to IS 2834, 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery.Cost per KVAR | Kvar | 432.0 | 432.0 | 2.0 | False | None | None | False | None | False | 864.0 | 0 |
2504993 | 76149 | None | code74 | Supplying fully automatic star-delta starter unit push button type with suitable wires 3 contactors, one adjustable thermal timer mounted on a common base plate held in steel enclosure for use on 400/440 volts 3 phase and wired after fixing to the wooden board for motor. upto 12.5 HP | Each | 6912.0 | 6912.0 | 1.0 | False | None | None | False | None | False | 6912.0 | 0 |
2504994 | 76149 | None | code75 | Supplying and fixing single phase preventer using necessary wires over an existing panel board suitable for motor upto 20 HP capacities. | Each | 805.0 | 805.0 | 1.0 | False | None | None | False | None | False | 805.0 | 0 |
2504995 | 76149 | None | code76 | Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc., using 40mm dia 2.9mm thick 2.5 mtr. Long GI Pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm alround with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts | No | 3750.0 | 3750.0 | 2.0 | False | None | None | False | None | False | 7500.0 | 0 |
2504996 | 76149 | None | code77 | Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depthupto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr,Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed. In Ordinary Soil | Mtr | 102.0 | 102.0 | 26.0 | False | None | None | False | None | False | 2652.0 | 0 |
2504997 | 76149 | None | code78 | Providing and laying in position 100mm dia stone ware pipe in existing trench. | Mtr | 39.0 | 39.0 | 26.0 | False | None | None | False | None | False | 1014.0 | 0 |
2504998 | 76149 | None | code79 | Supplying of 1.1 KV LT UG Cable XLPE or heat resistant PVC Insulated, PVC extruded, inner sheath armoured, UG LT cable as per IS - 1554 (part-1) or IS - 7098 part-1, Armouring strip thickness in average + 5% and resistivity 14 Ohms/kms (max) as per IS-3975. | Mtr | 113.27 | 113.27 | 30.0 | False | None | None | False | None | False | 3398.1 | 0 |
2504999 | 76149 | None | code80 | Labour charges for Laying of 1.1 KV class UG cable in existing trench GI pipe/ store ware pipe, on wall/ on pole as required.6 sqmm to 16 sqmm. | Mtr | 11.88 | 11.88 | 30.0 | False | None | None | False | None | False | 356.4 | 0 |
2505000 | 76149 | None | code81 | Providing and filling sand in excavated trench to cover already laid UG to a depth of 150 mm all-round the cable. | Mtr | 100.0 | 100.0 | 18.0 | False | None | None | False | None | False | 1800.0 | 0 |
2505001 | 76149 | None | code82 | GI Pipe - 40 mm Dia | Mtr | 295.0 | 295.0 | 15.0 | False | None | None | False | None | False | 4425.0 | 0 |
2505002 | 76149 | None | code83 | Epoxy Terminating Kit (Pothead) suitable for 1.1 kV, LTUG Cable Up to 4C x 50 Sqmm | No | 316.0 | 316.0 | 1.0 | False | None | None | False | None | False | 316.0 | 0 |
2505003 | 76149 | None | code84 | Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 32/63 Amps three phase 4 wire whole current class-1 Accuracy Energy Meter | Each | 5125.0 | 5125.0 | 1.0 | False | None | None | False | None | False | 5125.0 | 0 |
2505004 | 76149 | None | code85 | Arranging the power supply from CESCOM and payment of 2 MMD charges towards CESCOM for power sanction. | Each | 7513.39 | 7513.39 | 1.0 | False | None | None | False | None | False | 7513.39 | 0 |
2505005 | 76149 | None | code86 | Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work | Cum | 493.5 | 493.5 | 9.32 | False | None | None | False | None | False | 4599.42 | 0 |
2505006 | 76149 | None | code87 | Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. Note: Upto 110mm dia Coil shall be used. For Grade :HDPE Grade PE80-PN8.0, 90mm dia | Mtr | 249.9 | 249.9 | 23.0 | False | None | None | False | None | False | 5747.7 | 0 |
2505007 | 76149 | None | code88 | Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications | Cum | 128.1 | 128.1 | 9.32 | False | None | None | False | None | False | 1193.892 | 0 |